+ All Categories
Home > Documents > SNEL in France Implementation and results

SNEL in France Implementation and results

Date post: 22-Feb-2016
Category:
Upload: marv
View: 58 times
Download: 0 times
Share this document with a friend
Description:
SNEL in France Implementation and results. WHY SUCH A LAW ?. Several fatal accidents : May 2001 & May 2002 The French media emphasized the events Safety & Security are major citizens and politicians concerns The Lift is part of daily life Everybody feels concerned - PowerPoint PPT Presentation
Popular Tags:
18
SNEL in France Implementation and results
Transcript
Page 1: SNEL in France  Implementation  and  results

SNEL in France Implementation and

results

Page 2: SNEL in France  Implementation  and  results
Page 3: SNEL in France  Implementation  and  results

WHY SUCH A LAW ?

Several fatal accidents : May 2001 & May 2002

The French media emphasized the events - Safety & Security are major citizens and politicians concerns- The Lift is part of daily life- Everybody feels concerned

THE FRENCH AUTHORITIES CONSIDERED THE SUBJECT AS A PRIORITY

Page 4: SNEL in France  Implementation  and  results

French SNEL LAW

MINISTER GILLES de ROBIEN ON JULY 15th, 2002→ The owners have 15 years to retrofit 17 risks on their existing

lifts → A maintenance contract is compulsory, contents are clarified

(responsibilities) → Technical control by 3rd party every 5 years

Page 5: SNEL in France  Implementation  and  results

FRENCH PORTFOLIO IN 2003

450 000 units

60% > 20 years old

2000 accidents / year

10 fatal accidents /year (users & employees)

3 retrofit regulations (1951, 1986, 1995)

Only 2% of lifts are modernised each year

Page 6: SNEL in France  Implementation  and  results

1st phase : ended 31/12/2010

Unsafe locking device of landing door

Unlocking of landing door possible without a special tool

No or inadequate devices on power operated doors

Partially enclosed well with too low enclosure

No or inadequate safety gear Inadequate length of car apron

Insufficient safety spaces in headroom and/or pit

No or unsafe means of access to machine and pulley room Inadequate locking devices on

access to well and pit

6

Page 7: SNEL in France  Implementation  and  results

7

2nd phase: before July 2013

Drive system with bad levelling accuracy lifts < 1982

No or inadequate alarm device Inadequate glass in doors

Insufficient protection and marking of electrical equipment

No or inadequate means on sheaves pulleys and sprockets against injury

Inadequate lighting in machine & pulley room

Page 8: SNEL in France  Implementation  and  results

8

3rd phase: before July 2018

Ascending overspeed Drive system with bad levelling accuracy lifts > 1982

Page 9: SNEL in France  Implementation  and  results

MAINTENANCE & INSPECTION

MAINTENANCE OBLIGATIONS Inspired by EN 13015, with no deregulation

→ Clarify owners and maintenance companies obligations

→ Increase the level of contractual requirements

PERIODICAL TECHNICAL INSPECTION

Inspired by EN 13013-1 and EN81-80

→ Achieved by independent & competent third party

→ Periodicity = 5 years

Page 10: SNEL in France  Implementation  and  results

WHERE ARE WE TODAY ?(end december 2012)

Phase 1 dec 2010 Phase 2 july 2013 Phase 3 july 2018 Global 3 phases0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Series2Series1

95%

60%

20,5%

63%

Page 11: SNEL in France  Implementation  and  results

IMPACT ON SAFETY OF USERS

• Serious and fatal accidents were reduced drastically in 10 years • Most serious & fatal accidents have a cause covered by the 17 measures • Accidents occurred where the measures were not yet applied • Since 2000, 85% of these accidents could have been prevented by the SNEL law

2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 20120

1

2

3

4

5

6

7

8

9

Users fatalities

2003-2007 : 25 accidents2008-2012 : 4 accidents

Page 12: SNEL in France  Implementation  and  results

Others public accidents

Stopping accuracy

Door protection

Safety gear

Evolution 2008 2012 :- Total : 43% reduction- Stopping accuracy : 47% reduction- Doors protection : 33% reduction- Safety gear : 37% reduction

Main causes 2012 :- 41% fall due to bad stopping accuracy- 27% lack of protection on automatic doors- 12% excessive deceleration during stopping

3 main causes = 78% of the accidents

2008 2009 2010 2011 20120

50

100

150

200

250

300

350

400

450

500

Précision d'arrêtArrêt brusqueChocs lors fermeture des portes Total

Page 13: SNEL in France  Implementation  and  results

MAIN CONCLUSIONS ON USERS ACCIDENTS

These figures show that the SNEL law has positively impacted serious accidents which were covered by the 1st step of SAE. If nothing had been done, their number would have probably doubled as the other accidents were not yet affected by the SAE law.

Page 14: SNEL in France  Implementation  and  results

14

Workers serious & fatal accidents on existing lifts excluding road accidents

2004 2005 2006 2007 2008 2009 2010 2011 20120

1

2

3

4

5

6

hors risques SAEImpactés par mesures SAE

Others

Impacted by SAE

4 in the last 5 years 0 in 2012

Page 15: SNEL in France  Implementation  and  results

WORKERS SAFETY ACCIDENTS

2006 2007 2008 2009 2010 2011 20120

100

200

300

400

500

600

700

800

Total des accidents #Total maintenance #Accès local machinerie

Total accidents

Total maintenance

Machine room access

40% reduction in the last 4 years

Page 16: SNEL in France  Implementation  and  results

MAIN CONCLUSION FOR WORKERS

■ Only 20% of the accidents are covered by SAE (modernisation & installation not covered & no impact on travelling accidents) ■ SAE 2010 only covers space in extreme position & machine room access ■ -60% of accidents due to unsafe access to machine room■ Only 3 fatal accidents the last 3 years

Page 17: SNEL in France  Implementation  and  results

OTHERS IMPACTS OF THIS LAW

Reliability was improved after the start-up period Contribution to refurbishment of portfolio and

suppression of obsolescence Harmonized safety level on all lift generations Improved accessibility with alignment to EN 81-70

when possible (signals, buttons, remote alarm, level accuracy,…).

Impact on energy savings (Frequency converters, LEDS, stand-by…)

Page 18: SNEL in France  Implementation  and  results

http://lascenseurauquotidien.com/

Thank you for your attention


Recommended