COMcheck Software Version 4.0.5.1
Envelope Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New ConstructionVertical Glazing / Wall Area: 34%
Location: Round Rock, TexasClimate Zone: 2a
Construction Site: Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 1
Building Area Floor Area
1-Bldg Type 1 (Multifamily) : Residential 76551
Envelope Assemblies
Assembly CavityR-Value
Cont.R-Value
ProposedU-Factor
Budget U-Factor(a)
Gross Areaor
Perimeter
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Bldg Type 1] 21373 38.0 0.0 0.027 0.027Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 1] 8410 13.0 0.0 0.089 0.089Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, PF 0.30, VT 0.76, [Bldg. Use 1 - Bldg Type 1] (b)
2849 --- --- 0.350 0.750
Exterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 1] 2664 13.0 0.0 0.089 0.089Window 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Bldg Type 1] (b)
276 --- --- 0.350 0.750
Exterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 1] 8410 13.0 0.0 0.089 0.089Window 4: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, PF 0.30, VT 0.76, [Bldg. Use 1 - Bldg Type 1] (b)
3816 --- --- 0.350 0.750
Exterior Wall 4: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 1] 2664 13.0 0.0 0.089 0.089Window 5: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Bldg Type 1] (b)
588 --- --- 0.350 0.750
Semi-Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type1]
2440 11.0 0.0 0.094 0.089
Semi-Exterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type1]
370 11.0 0.0 0.094 0.089
Semi-Exterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type1]
270 11.0 0.0 0.094 0.089
Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Bldg Type 1] (c) 670 --- --- 0.730 0.730
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:221 ofPage
(c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance StatementCompliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed envelope systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Envelope PASSES: Design 2% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:222 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Interior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site: Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 1
Allowed Interior Lighting Power
AArea Category
BFloor Area
(ft2)
CAllowed
Watts / ft2
DAllowed Watts
(B X C)
1-Bldg Type 1 (Multifamily) 76551 0.60 45931
45931Total Allowed Watts =
Proposed Interior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
1-Bldg Type 1 (Multifamily)Type A: Type A: Corridor Wall Sconce: LED A Lamp 12W: 1 60 12 720Type C: Type C: Corridor Ceiling: LED Panel 19W: 1 120 12 1440Type D: Type D: 4' Striplight: LED Linear 33W: 1 24 31 744
2904Total Proposed Watts =
Interior Lighting Compliance StatementCompliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Interior Lighting PASSES: Design 94% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:223 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Exterior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site: Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 1
2 (Residentially zoned area)Exterior Lighting Zone
Allowed Exterior Lighting Power
AArea/Surface Category
BQuantity
CAllowed
Watts / Unit
DTradableWattage
EAllowed Watts
(B X C)
Exterior Entries (Entry canopy) 236 ft2 0.25 Yes 59
Total Tradable Watts (a) =Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
59
59
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
Exterior Entries ( Entry canopy 236 ft2): Tradable WattageType B1: Type B1: Exterior Wall Sconce: LED A Lamp 12W: 1 6 12 72Type F: Type F: Exterior Canopy: LED A Lamp 12W: 1 3 12 36
108Total Tradable Proposed Watts =
Exterior Lighting Compliance StatementCompliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Exterior Lighting PASSES: Design 84% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:224 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Mechanical Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Location: Round Rock, TexasClimate Zone: 2a
Construction Site: Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 1
Mechanical Systems List
Quantity System Type & Description
Heating: 1 each - Central Furnace, Electric, Capacity = 8200 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 11000 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
39 AHU/CU-A (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 13100 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 15600 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
14 AHU/CU-B (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 14500 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 14100 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
6 AHU/CU-C (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 15200 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 20400 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-CL (Single Zone):
Electric Storage Water Heater, Capacity: 50 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.86 EF
20 Water Heater 1:
Electric Storage Water Heater, Capacity: 40 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.88 EF
20 Water Heater 2:
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:225 ofPage
Quantity System Type & Description
Electric Storage Water Heater, Capacity: 30 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.89 EF
20 Water Heater 3:
Electric Instantaneous Water Heater, Capacity: 4 gallons No minimum efficiency requirement applies
1 Water Heater 4:
Mechanical Compliance StatementCompliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed mechanical systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Project Title:Data filename:
Round Rock Apartments - Bldg Type 1X:\16056\CALC\HVAC\Ecalcs\Building 1.cck
11/17/16Report date:226 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Envelope Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New ConstructionVertical Glazing / Wall Area: 24%
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 2
Building Area Floor Area
1-Bldg Type 2 (Multifamily) : Residential 74834
Envelope Assemblies
Assembly CavityR-Value
Cont.R-Value
ProposedU-Factor
Budget U-Factor(a)
Gross Areaor
Perimeter
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Bldg Type 2] 20472 38.0 0.0 0.027 0.027Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 2] 8340 13.0 0.0 0.089 0.089Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, PF 0.30, VT 0.76, [Bldg. Use 1 - Bldg Type 2] (b)
952 --- --- 0.350 0.750
Exterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 2] 2620 13.0 0.0 0.089 0.089Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Bldg Type 2] (b)
552 --- --- 0.350 0.750
Exterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 2] 10800 13.0 0.0 0.089 0.089Window 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, PF 0.30, VT 0.76, [Bldg. Use 1 - Bldg Type 2] (b)
3856 --- --- 0.350 0.750
Exterior Wall 4: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type 2] 2570 13.0 0.0 0.089 0.089Window 4: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Bldg Type 2] (b)
548 --- --- 0.350 0.750
Semi-Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type2]
2350 11.0 0.0 0.094 0.089
Semi-Exterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type2]
380 11.0 0.0 0.094 0.089
Semi-Exterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Bldg Type2]
280 11.0 0.0 0.094 0.089
Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Bldg Type 2] (c) 692 --- --- 0.730 0.730
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:221 ofPage
(c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance StatementCompliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed envelope systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Envelope PASSES: Design 2% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:222 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Interior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 2
Allowed Interior Lighting Power
AArea Category
BFloor Area
(ft2)
CAllowed
Watts / ft2
DAllowed Watts
(B X C)
1-Bldg Type 2 (Multifamily) 74834 0.60 44900
44900Total Allowed Watts =
Proposed Interior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
1-Bldg Type 2 (Multifamily)Type A: Type A: Corridor Wall Sconce: LED A Lamp 12W: 1 60 12 720Type C: Type C: Corridor Ceiling: LED Panel 19W: 1 120 12 1440Type D: Type D: 4' Striplight: LED Linear 33W: 1 24 31 744
2904Total Proposed Watts =
Interior Lighting Compliance StatementCompliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Interior Lighting PASSES: Design 94% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:223 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Exterior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 2
2 (Residentially zoned area)Exterior Lighting Zone
Allowed Exterior Lighting Power
AArea/Surface Category
BQuantity
CAllowed
Watts / Unit
DTradableWattage
EAllowed Watts
(B X C)
Exterior Entries (Entry canopy) 236 ft2 0.25 Yes 59
Total Tradable Watts (a) =Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
59
59
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
Exterior Entries ( Entry canopy 236 ft2): Tradable WattageType B1: Type B1: Exterior Wall Sconce: LED A Lamp 12W: 1 6 12 72Type F: Type F: Exterior Canopy: LED A Lamp 12W: 1 3 12 36
108Total Tradable Proposed Watts =
Exterior Lighting Compliance StatementCompliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Exterior Lighting PASSES: Design 84% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:224 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Mechanical Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 2
Mechanical Systems List
Quantity System Type & Description
Heating: 1 each - Central Furnace, Electric, Capacity = 8200 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 11000 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
27 AHU/CU-A (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 13100 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 15600 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
26 AHU/CU-B (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 14500 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 14100 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
3 AHU/CU-C (Single Zone):
Electric Storage Water Heater, Capacity: 50 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.86 EF
15 Water Heater 1:
Electric Storage Water Heater, Capacity: 40 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.88 EF
15 Water Heater 2:
Electric Storage Water Heater, Capacity: 30 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.89 EF
20 Water Heater 3:
Electric Instantaneous Water Heater, Capacity: 4 gallons No minimum efficiency requirement applies
6 Water Heater 4:
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:225 ofPage
Mechanical Compliance StatementCompliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed mechanical systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Project Title:Data filename:
Round Rock Apartments - Bldg Type 2X:\16056\CALC\HVAC\Ecalcs\Building 2.cck
11/17/16Report date:226 ofPage
11-18-16
REScheck Software Version 4.6.3
Compliance Certificate
Project Round Rock Apartments - Building Type 3
Energy Code: 2012 IECCLocation: Round Rock, TexasConstruction Type: Multi-familyProject Type: New ConstructionConditioned Floor Area: 52,335 ft2Glazing Area 10%Climate Zone: 2 (1688 HDD)Permit Date:
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers LLC1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Permit Number:
Compliance: Passes using UA trade-off1.1% Better Than Code Maximum UA: 2415 Your UA: 2388
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance: Maximum SHGC: 0.25 Your SHGC: 0.25
Envelope Assemblies
AssemblyGross Area
orPerimeter
CavityR-Value
Cont.R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 52,335 38.0 0.0 0.030 1570
Wall 1: Wood Frame, 16" o.c. 5,240 13.0 0.0 0.082 385
Window 1: Vinyl/Fiberglass Frame:Single Pane SHGC: 0.25
550 0.350 193
Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0'
230 0.0 1.042 240
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and othercalculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements inREScheck Version 4.6.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Round Rock Apartments - Building Type 3Data filename: X:\16056\CALC\HVAC\Ecalcs\Building Type 3.rck Page 1 of 1
11/16/16Report date:
GREG H. KLEBANOFF 11-18-16
2012 IECC EnergyEfficiency Certificate
Insulation Rating R-Value
13.00Above-Grade Wall
0.00Below-Grade Wall
0.00Floor
38.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.250.35Window
Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:Comments
COMcheck Software Version 4.0.5.1
Envelope Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New ConstructionVertical Glazing / Wall Area: 20%
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Building Type 4a - Clubhouse
Building Area Floor Area
1-Clubhouse (Convention Center) : Residential 5975
Envelope Assemblies
Assembly CavityR-Value
Cont.R-Value
ProposedU-Factor
Budget U-Factor(a)
Gross Areaor
Perimeter
Roof: Attic Roof with Wood Joists, [Bldg. Use 1 - Clubhouse] 6025 38.0 0.0 0.027 0.027Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Clubhouse] (c) 358 --- --- 0.730 0.730
NORTHExterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Clubhouse] 1402 13.0 0.0 0.089 0.089Window 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Clubhouse] (b)
395 --- --- 0.350 0.750
EASTExterior Wall 4: Wood-Framed, 16" o.c., [Bldg. Use 1 - Clubhouse] 576 13.0 0.0 0.089 0.089
SOUTHExterior Wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Clubhouse] 1660 13.0 0.0 0.089 0.089Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Clubhouse] (b)
462 --- --- 0.350 0.750
WESTExterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Clubhouse] 897 13.0 0.0 0.089 0.089Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product IDNA, SHGC 0.35, VT 0.76, [Bldg. Use 1 - Clubhouse] (b)
27 --- --- 0.350 0.750
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.(c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:231 ofPage
Envelope Compliance StatementCompliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed envelope systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Envelope PASSES: Design 8% better than code
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:232 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Interior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Building Type 4a - Clubhouse
Allowed Interior Lighting Power
AArea Category
BFloor Area
(ft2)
CAllowed
Watts / ft2
DAllowed Watts
(B X C)
1-Clubhouse (Convention Center) 5975 1.08 6453
6453Total Allowed Watts =
Proposed Interior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
1-Clubhouse (Convention Center)Type A: Type A: Corridor Wall Sconce: LED A Lamp 12W: 1 4 12 48Type C: Type C: Corridor Ceiling: LED Panel 19W: 1 93 12 1116Type D: Type D: 4' Striplight: LED Linear 33W: 1 3 31 93
1257Total Proposed Watts =
Interior Lighting Compliance StatementCompliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Interior Lighting PASSES: Design 81% better than code
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:233 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Exterior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Building Type 4a - Clubhouse
2 (Residentially zoned area)Exterior Lighting Zone
Allowed Exterior Lighting Power
AArea/Surface Category
BQuantity
CAllowed
Watts / Unit
DTradableWattage
EAllowed Watts
(B X C)
Entry canopy 754 ft2 0.25 Yes 188
Total Tradable Watts (a) =Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
188
188
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
Entry canopy (754 ft2): Tradable WattageType B1: Type B1: Exterior Wall Sconce: LED A Lamp 12W: 1 3 12 36Type F: Type F: Exterior Canopy: LED A Lamp 12W: 1 13 12 156
192Total Tradable Proposed Watts =
Exterior Lighting Compliance StatementCompliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Exterior Lighting PASSES: Design 76% better than code
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:234 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Mechanical Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Building Type 4a - Clubhouse
Mechanical Systems List
Quantity System Type & Description
Heating: 1 each - Central Furnace, Electric, Capacity = 32000 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 50600 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 16.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-1 (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 32000 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 53600 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 16.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-2 (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 35100 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 49800 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 16.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-3 (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 16200 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 22900 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-4 (Single Zone):
Heating: 1 each - Central Furnace, Electric, Capacity = 33500 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 44600 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-5 (Single Zone):
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:235 ofPage
Quantity System Type & Description
Heating: 1 each - Central Furnace, Electric, Capacity = 14000 kBtu/h No minimum efficiency requirement appliesCooling: 1 each - Split System, Capacity = 20900 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: LowCapacity Residential Proposed Efficiency = 14.00 EER, Required Efficiency: 9.70 EER (9.4 IPLV)Fan System: Unspecified
1 AHU/CU-6 (Single Zone):
Electric Storage Water Heater, Capacity: 40 gallons Proposed Efficiency: 0.95 EF, Required Efficiency: 0.88 EF
1 Water Heater 1:
Mechanical Compliance StatementCompliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed mechanical systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Project Title:Data filename:
Round Rock Apartments - Building Type 4a - ClubhouseX:\16056\CALC\HVAC\Ecalcs\Clubhouse.cck
11/17/16Report date:236 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Envelope Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New ConstructionVertical Glazing / Wall Area: 33%
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 4b Fitness
Building Area Floor Area
1-Fitness (Exercise Center) : Residential 3038
Envelope Assemblies
Assembly CavityR-Value
Cont.R-Value
ProposedU-Factor
Budget U-Factor(a)
Gross Areaor
Perimeter
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Fitness] 451 38.0 0.0 0.027 0.027Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Fitness] 2045 13.0 0.0 0.089 0.089Window 1: Metal Frame, Perf. Specs.: Product ID NA, SHGC 0.35, PF0.10, [Bldg. Use 1 - Fitness] (b)
677 --- --- 0.350 0.750
Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Fitness] (c) 238 --- --- 0.730 0.730
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.(c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance StatementCompliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed envelope systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Envelope PASSES: Design 0.1% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 4b FitnessX:\16056\CALC\HVAC\Ecalcs\Fitness.cck
11/17/16Report date:121 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Interior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 4b Fitness
Allowed Interior Lighting Power
AArea Category
BFloor Area
(ft2)
CAllowed
Watts / ft2
DAllowed Watts
(B X C)
1-Fitness (Exercise Center) 3038 0.88 2673
2673Total Allowed Watts =
Proposed Interior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
1-Fitness (Exercise Center)Type A: Type A: Corridor Wall Sconce: LED A Lamp 12W: 1 2 12 24Type C: Type C: Corridor Ceiling: LED Panel 19W: 1 54 12 648
672Total Proposed Watts =
Interior Lighting Compliance StatementCompliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Interior Lighting PASSES: Design 75% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 4b FitnessX:\16056\CALC\HVAC\Ecalcs\Fitness.cck
11/17/16Report date:122 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Exterior Lighting Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 4b Fitness
2 (Residentially zoned area)Exterior Lighting Zone
Allowed Exterior Lighting Power
AArea/Surface Category
BQuantity
CAllowed
Watts / Unit
DTradableWattage
EAllowed Watts
(B X C)
Exterior Entries (Entry canopy) 76 ft2 0.25 Yes 19
Total Tradable Watts (a) =Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
19
19
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting PowerE
(C X D)D
FixtureWatt.
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
Exterior Entries ( Entry canopy 76 ft2): Tradable WattageType B1: Type B1: Exterior Wall Sconce: LED A Lamp 12W: 1 2 12 24Type F: Type F: Exterior Canopy: LED A Lamp 12W: 1 2 12 24
48Total Tradable Proposed Watts =
Exterior Lighting Compliance StatementCompliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Michael L. DodaneName - Title Signature Date
Exterior Lighting PASSES: Design 92% better than code
Project Title:Data filename:
Round Rock Apartments - Bldg Type 4b FitnessX:\16056\CALC\HVAC\Ecalcs\Fitness.cck
11/17/16Report date:123 ofPage
11-18-16
COMcheck Software Version 4.0.5.1
Mechanical Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type: New Construction
Location: Round Rock, TexasClimate Zone: 2a
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Project Information
Energy Code:
Round Rock Apartments - Bldg Type 4b Fitness
Mechanical Systems List
Quantity System Type & Description
Mechanical Compliance StatementCompliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application. The proposed mechanical systems have beendesigned to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.5.1 and to comply with any applicablemandatory requirements listed in the Inspection Checklist.
Greg H. KlebanoffName - Title Signature Date
Project Title:Data filename:
Round Rock Apartments - Bldg Type 4b FitnessX:\16056\CALC\HVAC\Ecalcs\Fitness.cck
11/17/16Report date:124 ofPage
11-18-16
REScheck Software Version 4.6.3
Compliance Certificate
Project Round Rock Apartments - Building Type 4b Living Units
Energy Code: 2012 IECCLocation: Round Rock, TexasConstruction Type: Multi-familyProject Type: New ConstructionConditioned Floor Area: 1,894 ft2Glazing Area 19%Climate Zone: 2 (1688 HDD)Permit Date:
Construction Site:Round Rock, TX
Owner/Agent:MN Capital Strategies2204 Lakeshore DriveSuite 450Birmingham, AL 35209205-484-2836
Designer/Contractor:Migre Engineers LLC1200 W SR 434Suite 301Longwood, FL 32750407-636-7999
Permit Number:
Compliance: Passes using UA trade-off2.7% Better Than Code Maximum UA: 367 Your UA: 357
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance: Maximum SHGC: 0.25 Your SHGC: 0.25
Envelope Assemblies
AssemblyGross Area
orPerimeter
CavityR-Value
Cont.R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 2,090 30.0 0.0 0.035 73
Wall 1: Wood Frame, 16" o.c. 2,128 13.0 0.0 0.082 141
Window 1: Vinyl/Fiberglass Frame:Single Pane SHGC: 0.25
408 0.350 143
Greg H. KlebanoffName - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and othercalculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements inREScheck Version 4.6.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Round Rock Apartments - Building Type 4b Living UnitsData filename: X:\16056\CALC\HVAC\Ecalcs\A5 Units.rck Page 1 of 1
11/17/16Report date:
11-18-16
2012 IECC EnergyEfficiency Certificate
Insulation Rating R-Value
13.00Above-Grade Wall
0.00Below-Grade Wall
0.00Floor
30.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.250.35Window
Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:Comments