Soil & Waste Systems CI/SfB July 2003 (52.6) In6
Transcript
Page 1: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Soil & Waste Systems

CI/SfB

July 2003

(52.6) In6

Page 2: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Contents

Company Information 1

Sanitary Pipework Design 2

Soil

Pipes and Couplings 3

Bends 4

Branches 6

Boss Branches 8

Reducers and Access Pipes 10

Clips and Firesleeves 11

Vent Terminals 12

Manifold System 13

Floor Gullies 14

Plastic Shower Gullies 15

Aluminium Shower Gullies 16

Adaptors 17

Flat Roof Outlets 18

Pipe Support System 19

WC Connectors (Multikwik) 20

WC Connectors (Marley) 22

Waste

Pipes and Bends 23

Clips/Tees/Access Caps 24

Reducers/Adaptors 25

Vents/Fire Sleeves 26

Push-Fit Waste 27

Waste Traps 29

Overflow 33

Accessories 35

Technical Information 36

Conte

nts

Page 3: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

1

Info

rmat

ion

The Company:

MFP has over thirty five years experience in the development and manufacture of PVCu drainage systems, and is a major supplier of quality products to the construction industry in Ireland. MFP offer a comprehensive range of Rainwater, Soil and Waste and Underground drainage systems conforming to appropriateNational Standards.

Product Range:

The advent of PVCu was the greatest single advancement in the development of sanitary pipework systems. MFP has, since 1967, in association with MarleyPlumbing and Drainage, been the leader in Research and Development of singlestack systems and have introduced many technical innovations which simplify workon site, improve performance and reduce installation costs.

The MFP range of products for soil and waste disposal is designed to satisfy therequirements of all types of buildings, whether domestic, industrial, commercial orpublic, and forms part of a complete MFP range of above and below ground drainagesystems. Soil systems are available in diameters of 82, 110 and 160mm. Waste systems are available in diameters of 32, 40 and 50mm.

Standards:

MFP Soil and Waste systems are manufactured to conform to appropriate nationaland international standards.

MFP is licensed by the British Standards Institute to apply the kitemark to productsmanufactured to BS EN 1329-1:2000 for Unplasticised Soil and Ventilating Pipes andFittings. This mark may be used only by those licensed under the certification markscheme operated by B.S.I..

The presence of the kitemark on, or in relation to, a product is an assurance that thegoods conform to an appropriate standard, and have been produced under a qualitysystem conforming to I.S. EN ISO 9002 : 1994 which involves regular third partyinspection of the manufacturer’s works.

Installation:

All products illustrated in this brochure must be installed correctly in accordance with the relevant statutory regulations. Guidance on the design andinstallation of sanitary pipework systems may be had in:

1997 Building Technical Guidance Document H, Drainage Regulations and Waste Disposal

BS EN 12056: 2000, Code of Practice for Sanitary PipeworkPart 1 to 5

BS EN 1329-1:2000 Specification for Unplasticised PVC Soil and Ventilating Pipes,Fittings and Accessories

BS 5255: 1989 Specification for Plastic Waste Pipe and Fittings

BS EN 1451-1:2000 Specification for Polypropylene Waste Pipe and Fittings

Technical Advice:

A technical advisory and computer aided design service is available to give guidanceon design and the correct use of all MFP products. Literature describing products inboth the Underground Drainage and Sewerage Systems and the MFP RainwaterSystems is available on request.

Information

Page 4: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Soil

2

San

itar

y P

ipew

ork

Des

ign Irish Building Regulations 1997 requirements are set

out in Technical Guidance Document H, Drainage andWaste Disposal.

UK Building Regulations 2000 requirements are set out inApproved Document H1, Drainage and Waste Disposal.

Further and more detailed information on sanitarypipework systems is available in Code of Practice BS EN 12056: 2000, Part 1 to 5, which contains informationon levels of performance and discharge rates from

sanitary appliances, as well as extensive recommenda-tions for design, installation, testing and maintenance ofabove ground non-pressure pipework systems. The recommendations contained in this Code of Practiceare based on improved technology in plumbing andresearch undertaken by the Building ResearchEstablishment and product manufacturers, the result ofwhich have been proven in practice.

Regular consultation is essential between architects andplumbing engineers throughout all stages of design. Thiswill help to ensure that the positions of ducts and sanitary appliances permit an efficient pipework systemto be installed with minimum cost.

All the technical information contained in this brochureis based on these publications and, while every efforthas been made to ensure its accuracy, no responsibilityis accepted for errors or omissions.

Pipework Sizes

PVCu Soil systems pipework is available in 82, 110 and160mm diameters nd is manufactured to meet therequirements of either BS EN 1329-1:2000 or LocalGovernment Specification.

Waste systems pipework in PVCu and MPVCu is manufactured to satisfy 1989 in sizes 32, 40 and 50mmdiameter.

The pushfit waste system in polypropylene is in accor-dance with BS EN 1451-1:2000 and is available in sizes32 and 40mm diameters.

Thermal Movement

The co-efficient of linear expansion of PVCu is 6 x 10 –5mm/mm/°C, which means that PVCu pipeworkmay expand or contract by up to 0.6mm per metre per10°C change of temperature. It is important, therefore,that this movement is allowed for by providing an expansion gap at ring seal joints. This is done by push-ing the spigot fully into the ring seal socket, marking thepipe at the socket edge and then withdrawing the pipeby 10mm. Care should be taken that this gap is not lost during further installation.

Chemical Resistance

MFP Plastics sanitary pipework and fittings are highlyresistant to chemicals normally found in domesticsewage and waste water discharges. Further comprehen-sive information on the chemical resistance of plasticpipework may be found in BS CP312: Part 1: 1973,Code of Practice for Plastics Pipework.

Push-fit polypropylene pipes and fittings cannot be solvent welded and if installed on the external surface ofa building where they could be subjected to ultra violetlight some protection is required by the application of asuitable paint or by boxing in.

Storage and Handling

Loose pipes should be stacked on a reasonably flat surface, free from sharp stones or such projections.They should be supported on timber battens not lessthan 75mm wide, at spacings not greater than 1M cen-tres. Side supports should be of similar timber battensat intervals not greater than 1.5M centres. Pipes of different diameter and wall thickness should, preferably,be stacked separately or, where this is not possible, larger diameter pipes should be placed on bottom.Spigot and socket pipes should be stacked having sockets positioned at alternate ends protruding toensure pipes are evenly supported along their fulllength. Pipe stacks should not exceed seven layers, or2M high.

Pipes which are stored in the open for long periodsshould be protected from strong sunlight by coveringwith reflective sheets.

Fittings supplied in polythene bags or cardboard boxesshould be stored away from direct sunlight. Bags shouldbe opened to prevent build-up of temperature. Solventcement should be stored in a cool place, away from anyheat source.

PVCu pipes and fittings are strong, though lightweight,and therefore very easily handled. However, it is necessary to take reasonable care in handling to prevent damage in extreme cold conditions. Pipesshould, preferably, be loaded and unloaded by hand, but if mechanical handling is used, protected slings are recommended.

Sanitary Pipework Design

Page 5: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

3

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Pip

es/C

oup

lings

Size mm 82 110 160Code SE300 SE400 SE600

A 128 109 190B 76 61 107C 46 48 77

Colour g g b w g

Pipe socket

Pipe - plain ended

Size mm 82 110LG 110BSLength 3 metres

Code SL303 SL403 SLH403Colour g b g g

Length 4 metresCode SL404 SLH404

Colour b g g

Double spigot with chamfer each end

Pipe - socketedRing seal socket Ring seal/solvent socket

Double ring seal socket

Size mm 110Code SER400

A 133B 65

Colour b g

CouplingDouble ring seal socket

110mm pipe is manufactured to Irish Local Government ’77 specifications and BS EN 1329-1:200082,4mm pipe + 160mm pipe are manufactured to BS EN 1329-1:2000 only.

Size mm 82 110LG 110BS 160Length 2.5metres

Code SP4025SPH4025A 128 128B 70 70

Colour g b g

Length 3 metresCode SP303 SP403 SPH403 SP603

A 100 128 128 182B 76 70 70 107

Colour g b g g w g

Length 4 metresCode SP404 SPH404

A 128 128B 70 70

Colour b g g

Length 6 metresCode SP406 SPH406

A 128 128B 70 70

Colour g b g

Size mm 82 110 160Code SES301 SES401 SES601

A 93 110 185B 44 53 82C 82 110 161

Colour g g g

CouplingDouble solvent socket

A

A

BB

C

A

B

A

B

C

Page 6: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

4

Coloursg=greyb=blackw=white

Ben

ds

Size mm 82 110 160Code SB35 SB45 SFB65

A 82 145 175B 80 125 160C 65 80 96

Colour g b g w g

Size mm 82 110 160Code SB31 SB41 SFB61

A 133 158 285B 112 157 275C 65 70 96

Colour g b g w g

Short radius bend 45°Short radius bend 87.5°Ring seal socket/spigotRing seal socket/spigot

Short radius bend 87.5°Ring seal socket/socket

Size mm 110Code SE402

A 311B 82

Colour g

Triple socketExpansion/contraction socketring seal socket/spigot

Size mm 110Code SBR4287

A 166B 166C 73

Colour g b

Short radius access bend 87.5°

Size mm 110Code SB42

A 172B 174C 80

Colour b g

Size mm 110 160Code SE405 SE605

A 121 210B 60.5 105

Colour g g

Slip couplingDouble ring seal socket

A

B A

BC

A

AB

BC

AA

B BCC

Page 7: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

5

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Ben

dsOffset bend (spigot end)

Solvent socket/spigot

Size mm 82 110 110 160Code SB37 SB46 SB47 SB67Angle 11-87.5° 5-14° 21-90° 31-90°

A 205 125 210 285B 200 135 205 275C 65 82 82 96

Colour g g g b g

Adjustable bendRing seal socket/spigot

Adjustable access bendRing seal socket/spigotwith rear access

Size mm 82 110 110 160

Code SNE300 SNE450 SNE405 SNE 600Angle 67.5˚ 45° 67.5˚ 67.5˚

A 103 98 100 178B 41 45 73 182C 65 73 60 96

Colour g g b g b w g

Offset bend (socket end) Ring seal/solvent socket

67.5°

45°

Size mm 82 110 160Code SNE301 SNE451 SNE 601Angle 67.5° 45° 67.5°

A 103 102 170B 41 67 172C 13 26 83

Colour g g b g

Short radius bend 45°

Size mm 110Code SBR4245

A 113B 113C 73

Colour g b

Size mm 82 160Code SB38 SB620Angle 64-87.5° 55-90°

A 212 285B 208 275C 65 96

Colour g g

Ring seal socket /socket

A A

A

B B

B

C

C

C

A

A

A

B

B

B

C

C

C

Adjustable bend

Size mmCode MFBSAngle Adjustable 0° to 90°Colour g b

Page 8: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

6

Coloursg=greyb=blackw=white

Bra

nch

es

Size mm 110Code SY45

A 322B 169C 82

Colour g b

Equal branch 76°Ring seal socket/spigot three boss upstands

Size mm 110Code SYR4387

A 293B 161C 71

Colour g b

Equal branch 87.5°Socket/socketPlain

Size mm 82 110Code SY34* SY402

A 306 300B 200 150C – 60D 195 175

Colour g g b

*Adjustable 64-87.5°

Equal access branch 87.5°Ring seal socket/spigottwo boss upstandsrear access

Size mm 82 110Code SY33* SY400

A 306 290B 200 161C — 71D 195 160

Colour g g b*Adjustable 64-87.5°

Size mm 110Code SY405

A 300B 150C 60D 175E 76

Colour g b w

Equal branch 87.5°

Equal branch 87.5°

Ring seal sockets/spigotthree boss upstands

Ring seal sockets/spigotfive boss upstands

Size mm 160Code SY601

A 438B 245C 96D 260

Colour g

Plain equal branch 87.5°Ring seal sockets/spigot

AA

BB

CC

D

A

B

CD

E A

B

CD

A

B

C

A

B

C D

Page 9: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

7

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Bra

nch

es

Size mm 110Code SY404

A 288B 141C 54D 76

Colour g

Double branch 87.5°Ring seal sockets/spigotfour boss upstands

Size mm 82 110 160Code SY36 SY460 SY63

A 244 320 400B 160 214 200C 65 82 90

Colour g g w g

Equal branch 45°Ring seal sockets/spigottwo access upstands

Size mm 110Code SW64

A 384B 160C 192

Colour g

Multi-branch 87.5°Ring seal socket/spigotfour 110/50mm boss upstands

Size mm 110Code SE404

A 127B 126C 82

Colour g

Multi-branch socketFor use with Multi-branch

Size mm 110Code MFYD

Angle Adustable 45˚ to 90˚

Colour bg

Adj. Branch

A

B

C

A

B

C

D

A

B

C A

B

C

Size mm 110Code SE45

Colour g

Multi-branch access capFor use with Multi-branch

Page 10: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

8

Coloursg=greyb=blackw=white

Boss

Bra

nch

es

Size mm 82 110 160Code SW30 SW40 SW60

A 240 244 335B 120 123 110C 70 70 96

Colour g b g w g

Boss branch 90°

Boss branch 87.5°

Ring seal socket/spigotfour boss upstands, one open

Solvent sockets

Size mm 110x32 110x40Code SW415 SW41

A 204 204B 86 86C 82 82

Colour b g b g w

Size mm 110x32 110x40 110x50Code SWS415 SWS41 SWS42

A 170 170 170B 85 85 85C 48 48 48

Colour b g w b g w g

Boss branch 87.5°Ring seal socket/spigot

Size mm 110Code SCB41

A 245B 210C 178D 186

Colour g

Collar boss branch 87.5°Solvent socket/spigotfour boss upstands, one open

Size mm 160x110Code SY64

A 375B 229C 216

Colour g

Reducing branch 87.5°Ring seal sockets/spigotthree boss/access upstands

Size mm 110Code SY411

A 288B 141C 54

Colour g

Corner branch 87.5°Ring seal sockets/spigotone boss upstand

AB

CAB

D

C

A

B

C

A

B

C

A

B

C

A

B

C

Page 11: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

9

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Boss

Bra

nch

es

Knuckle bend 90°Boss branch 45°

Boss connector 87.5°

Solvent socketssingle 50mm/three boss upstands

Solvent socket welds inside boss upstands

Ring seal socket/spigotfor use with all boss upstands

Strap-on boss 90°Including nut and bolt

Socket plug/reducerPush fits into ring seal socketsingle boss upstand no insert

Size mm 82 110Code SWS3135 SWS4135

A 160 186B 80 93C 86 145

Colour g g

Size mm 110Code SE41

A 105B 135

Colour b g

Size mm 40 50Code KBK25 KBK35

A 48 59B 48 50C 23 20

Colour b g g

Size mm 110x32 110x40 110x50Code SWS4150 SWS410 SWS420

A 70 70 86B 55 62 75

Colour b g b g b g

Size mm 32 40 40 50Code SA411 SA421 SA425* SA420

A 43 43 26 64B 21 21 30 48

Colour b g w b g w b g b g

*Solvent socket

Universal AdapterUnversal 110mm spigot adaptor/plug forwaste 30,40, or 50mm pipe sizes

Size mmCode MKUA

A 110B 34

Colour b g w

AB

CA

BC

A

B

AB

A A

B

BA

B

Page 12: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

10

Coloursg=greyb=blackw=white

Red

uce

rs/A

cces

s P

ipes

Size mm 82x50 110x50Code SRM30 SRM402

A 70 48B 48 25C 19 19

Colour g g

Size mm 82 110Code SF31 SF41

A 248 244B 123 123C 76 70

Colour b g b g

Size mm 110 160Code SFS41 SF611

A 150 287B 75 142C 32

Colour b g w g

Reducer

Access Pipe

Access Pipe

Solvent socket to standard boss upstand

Solvent socket

Ring seal socket

ReducerSolvent sockets

Size mm 82x68 110x68Code SRM325 RRM425

A 35 41B 20 25C 12 13

Colour b g b g

A

B

C

AB

CABC

ABC

ReducerRing Seal socket/spigot

Size mm 110x82 160x110Code SRM304 SRM604

A 192 219B 78 90C 82 82

Colour g g

A

B

C

Size mm 82 110 160Code SE30 SE40 SE62

A 110 130 195B 30 30 40

Colour g g g

Access Cap

A

B

Page 13: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

11

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Clip

s/Fir

esle

eves

Length 1 metreCode SC621

Colour g

Size mm 82 110Code SC35 SC45

A 125 150B 93 101

Colour g g b w

Barrel Clip Collar

Barrel Pipe Clip

Plasticised PVC when cut to length fits 82/110/160mm

PVCu

Size mm 82 110 160Code SC31 SC41 SC61

A 135 152 240B 93 101 121

Colour g g b g

Socket Pipe ClipPVC coated mild steel including nut and bolt

Pipe WrapsUp to 4 hour rating

Size mm 82 110 160Code SFW34 SFW44 SFW64

A 308 395 580B 100 100 100

Size mm 82 110 160Code SFC34 SFC44 SFC64

A 83 111 161B 43 43 74C 120 155 210D 140 165 215

Colour blue blue blue

Fire Sleeves

AB

AB

A

B

Up to 4 hour rating A

BC D

Code UFC1Number of collars per roll

82mm, 110mm, 160mm.6 5 3

Universal Fire Collar

Page 14: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

12

Coloursg=greyb=blackw=white

Ven

t Te

rmin

als

Size mm 110Code SV422

A 119B 24C 92

Colour b

Vent terminal

Size mm 82 110 160Code SV31 SV43 SV61

A 51 57 51B 94 130 169C 25 25 25

Colour b g b w b

Weathering CollarPVCu solvent joint to pipeSV31, SV61 weathering collars are available in black rubber only

Size mm 110 110Code RS1 RS3

A 450 610B 450 610

Weathering SlateAluminium slate with rubber hood

Size mm 82 110Code SVD3 SVD4

A 108 124B 118 138C 40 50

Colour g g

Size mm 110Code SVC1

A 120B 75C 24

Colour b g w

Durgo automatic air admittance valveRoof Cowl/Vent TerminalPush fits into ring seal socketincludes a polystyrene insulating hood

Solvent socket

Vent Terminal

Size mm 82 110 160Code SV321 SV42 SV62

A 90 117 160B 30 34 75C 75 95 170

Colour g b g b w g

Solvent socketSV62 terminal available in PVC coated wire only

A

BC

A

B

C

A

B

C

B

A

C

B

A

C

B

A

Page 15: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

13

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Man

ifold

Sys

tem

Code SA323WA 141B 24

Colour w

Size mm 90Code SM44W

A 117B 134C 46

Colour w

Length 300 mmCode SM45W

A 96B 46C 90

Colour w

WC Seal and Cap

WC Connector

Extension Pipe

Suits WC spigot size 83 -114 mm

Solvent socket/pan socket

Size mm 90Code SM43WAngle 50-90°

A 119B 75

Colour w

Spigot Bend (Adjustable)Solvent spigot50 mm boss upstand

Size mm 110x90Code SM41W

A 214B 50C 24

Colour w

Size mm 90Code SM42WAngle 50-90°

A 108B 134C 75D 60

Colour w

Branch

WC Bend (Adjustable)Solvent spigot/pan socket50 mm boss upstand

Solvent socket

A

B

A

B

A

B

C

A

BC

A

B

C

A

B

C

D

Page 16: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

SoilSoil and vent componentsto BS EN 1329-1:2000

14

Coloursg=greyb=blackw=white

Flo

or

Gullie

s

Size mm 50 110x82Code MD200 MD400

A 76 80B 50 mm Multifit 110 mm BSSC For MD 100 For MD 100-3

Size mm 50 82Code MD100 MD100-3

A 151 151B (I.D) 110 110C (Outlet) 50/82 82onlyD (Inlet) I.D. 40 mm pipe O.D. 50 mm pipe

Colour g g

* Height adjustable by using 110 mm pipe60 mm water seal

Outlet fitting

Trapped Floor GullyAdjustable height*

White ABS Tile, Grid & Cover

Size mm 150x150 200X200Code MDTOPC-WH MDTOP20C-WH

A 150 200B 67 67C 110 110

Solvents welds directly to gully or to 110 mm extension pipe

Size mm 32 40Code MD125 MD150

A 76 76B Solvent welds to gully inletC Fits 32 mm pipe Fits 40 mm pipe

For use with non-solvent weld pipe to BSS

Inlet fitting

B

AA

BC C

A

C B

B

A

C

A

B

D

C

Size mm 150x150 200X200 150x150Code MD-TOP MD-TOP20 FG TOP6SS

A 150 200 150B 67 67 67C 110 110 110

Solvents welds directly to gully or to 110 mm extension pipe

Stainless Steel Tile & Cover White ABS Tile & Grid

Size mm 150x150 200X200Code MDTOP-WH MDTOP20-WH

A 150 200B 67 67C 110 110

Solvents welds directly to gully or to 110 mm extension pipe

B

A

C

B

A

C

B

A

C

Suitable for shower area.Suitable for shower area.Suitable for washdown area.

Suitable for washdown area.

Page 17: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

15

Soil

Pla

stic

Show

er G

ullie

s

Coloursw=whitebl=bluebn=boness=stainlesssteel

Size mmCode TSG1T6 TSG1T8

A 150 200B 200 200C 130 130D 90 90E 100 100

Colour w ss w ss

Horizontal Socket - Tiled Floor

Size mmCode TSG2T6 TSG2T8

A 150 200B 200 200C 130 130D 90 90E 110 110

Colour w ss w ss

Vertical Spigot - Tiled Floor‘S’ outlet 75mm Water Seal

Size mmCode TSG1

A 119B 200C 130D 90E 100

Colour w bl bn ss

Horizontal Socket - Sheet Floor

Size mmCode TSG2

A 119B 200C 130D 90E 110

Colour w bl bn ss

Vertical Spigot - Sheet Floor‘S’ outlet 75mm Water Seal

OptionsCover Plates available in white plastic, stainless steel, blue & bone

OptionsTiles available in white plastic & stainless steel

‘P’ outlet 75mm Water Seal

‘P’ outlet 75mm Water Seal

A

E

B

AA

B

C

E

D C D

B

E

A

CD

E

B

C

D

Page 18: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Soil

16

Alu

min

ium

Show

er G

ulli

esColoursw=white

Size mm 40Code DF210

A 108B 200C 170D 134 E 47F 43

Colour W

Vertical Spigot - Sheet Floor‘S’ outlet 75mm Water Seal

Size mm 40Code DF215

A 108B 200C 170D 134 E 47F 43

Colour W

Horizontal Socket - Sheet Floor‘P’ outlet 75mm Water Seal

Size mm 40Code DF220

A 108B 200C 170D 150E 47F 43

Colour W

Vertical Spigot - Tiled Floor‘S’ outlet 75mm Water Seal

Size mm 40Code DF225

A 108B 200C 170D 150 E 47F 43

Colour W

Horizontal Socket - Tiled floor‘P’ outlet 75mm Water Seal

OptionsGratings are supplied in white as standard, alternative colour options are available on request.

OptionsThe tile set is supplied in white as standard, alternative colour options are available on request. A nickel bronze version is also available.

B B

A

E F

A

E F

CD

A

E

F

CD

BCD

A

E

F

BCD

Page 19: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

17

SoilSoil and vent componentsto BS EN 1329-1:2000

Coloursg=greyb=blackw=white

Ad

apto

rs

Size mm 82 110 160PVC to cast iron – Equal

Code 062-062 112-112 162-162A 60 112 162B 60 112 162C 88 101 152

Colour b b b

PVC to cast iron – UnequalCode 084-060 117-025

A 85 111B 60 85C 101 101

Colour b b

PVC to ductile iron – EqualCode 123-111

A 120B 111C 101

Colour b

PVC to clay – EqualCode 133-084 1033-112 190-162

A 133 133 187B 85 111 162C 101 101 152

Colour b b b

PVC to clay – UnequalCode 187-111

A 187B 111C 152

Colour bOther Sizes Available On Request

Adaptor (flexible PVC)

Size mm 82 110 160Clay to Clay

Code 133-133 188-188A 133 191B 133 191C 101 152

Colour b bStraignt Connector

Code 086-086 113-059A 85 111B 85 60C 101 101

Colour b b

Size mm 32 40Connector

Code 041-041 049-049A 40 48B 40 48C 88 88

Colour b b

Other Sizes Available On Request

Adaptor (Flexible PVC)

Size mm 110 110Code MKEP110 MKES110

A 165 165B 110 110C 110 spigot 110 socket

Colour b b

Universal Pipe Adaptor

B

A

C

B

A

C

C

B

A

C

B

A

Page 20: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Soil

18

Coloursg=greyb=blackw=white

Fla

t R

oof

Outl

ets

Size mmCode SOF1

A 343B 141C 55

Colour g

FlangeSolvent socket fits all sizes

Size mm 160Code SOF60

A 390B 175

Colour g

Flat roof outlet

Size mmCode SOF12

Colour g

Flat roof outlet gridFits SOF1

Size mmCode SOB1

Colour g

Balcony outlet gratingFits SOF1

Size mm 82 110Code SGS31 SGS41

A 137 134B 133 139

Colour g g

Straight Flange Connector

AA

B

B

Size mm 82 110Code STS310 STS41Angle 85° 85°

A 106 104B 149 80

Colour g g

Bent Flange Connecotor

A

B

A

B

Page 21: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

19

Horizontal pipe support system Zinc electro-plated; for internal use only

Size mm 82 110 160 200 250Code JB32 JB42 JB62 JB200 JB250

Pipe bracket

Size 32 40 50Code JDB1 JDB2 JDB3

Single support bracket

Two piece

Size mm 50Code JCB3

Channel bracketSmall diameter

Size mm 82 110 160Code JBP32 JBP42 JBP62

Double support base plate

Code JDP1

Single support base plate

Code JCU1

Channel strip union

Code JCA1Angle 90°

Channel strip angle

Size mm 20x6Code JNB10

Nuts and boltsSupplied in packs of ten

Length 1mCode SC621

Barrel clip collarPlasticised PVC when cut to length fits all sizes of pipe

Size 1m 2mCode JCS1 JCS2

Channel strip

Soil

Pip

e S

up

port

Sys

tem

Code JAC1 JAC2Angle 90° 45°

Angle cleat

Page 22: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Design Code WC Pan Spigot Soil Pipe X Y ZO.D. “A” I.D. “B” mm mm mm

Straight

MKS1 108-114mm 99-105mm 43 122 15

MKS2 97-108mm 99-105mm 43 101 9

MKS3 108-114mm 88-92mm 40 120 20

MKS4 97-108mm 99-105mm 43 155 9-64

MKS5 76-95mm 99-105mm 43 101 9

MKS7 97-108mm 88-92mm 40 120 20

Offset

MKO1 108-114mm 99-105mm 41 125 21

MKO2 97-108mm 99-105mm 41 125 21

MKO3 108-114mm 88-92mm 38 125 24

MKO4 97-108mm 99-105mm 41 140

MKO7 97-108mm 88-92mm 38 125

Bends

MKB1/14 97-108mm 99-105mm 55 133 31

MKB21/90 97-108mm 99-105mm 62 103 50

MKB31/90 97-108mm 99-105mm 45 190 50

MKBAR90 97-108mm 99-105mm

MKB21 108-114mm 99-105mm 44 71 40

MKB21/104 97-111mm 99-105mm 45 190 45

MKBB21/90 97-108mm 99-105mm 62 103

MKBB31/90 97-108mm 99-105mm 45 190

MKF330 97-108mm 99-105mm N/A N/A

Extension Pieces – do not fit direct to WC spigot

MKE A Use to extend 95-105mm 50 255 60Multikwik connectors

MKE B Use to extend 88-92mm 50 255 60Multikwik connectors

MKL1 Multilink

MK/SHRD Shroud

Coloursw=white

WC

Connec

tors

Non Standard Sizes to Special Order.

For Horizontal Outlet WC Pans (to BS 5503 and 5504) use only sizes marked Leaflet with further information and details of non-standard sizes available on request

BA

yz x

z

97°

104°

z

A

B

x

yz

A

B

y

16m

m

A

B

y4mm

90°

z

z

x

x

Standard Multikwik range for 4” Pan Spigots to BS5503 and BS5504

(Used as a Male Sleeve when linking other Multilink Connectors).

14°

90°

97°

104°

ADJUSTABLE

FLEXIBLE CONNECTORS

B

y

x

y

xB

A

A

B

y

x

A

B

y

x

A

®

20

Page 23: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

21

WC

Connec

tors

Multikwik WCs are particularly prone to obstruction in or near the trap through misuse. Multikwik connectors are designedto allow for easy removal and replacement of the pan.

Manufacture

Multikwik WC pan connectors are moulded from white EVA (ethylene vinyl acetate) copolymer. The connector body is man-ufactured by injection moulding and the sealing rings are produced by moulding from a proven synthetic elastomeric com-pound.

Agrément Board Certificates

The Agrément Board have issued certificates relating to Multikwik WC pan connectors for use on Above Ground SanitaryPipework Systems.

No. 76/399 published in September 1976 was the first assessment and this has now been replaced and extended by cer-tificates Nos. 79/694, 83/1089, 84/1362 and 88/2107.

Application

Multikwik connectors are suitable for jointing to:

• P or S trap Washdown/Siphonic WC pans to BS 1213:1945

• Horizontal outlet WC pans to BS 5503 and BS 5504 Part 1 1977

• 110mm uPVC to BS EN 1329-1:2000

• 110mm uPVC to BS 4660: 1973

• 102mm Clay to BS 65: 1981

• 102mm Cast Iron to BS EN 877:1999

• 100mm ‘Timesaver’ Cast Iron and other materials withsimilar varying internal diameters

Fitting

Multikwik flexible connectors are designed to seal without the use of lubricant. The inside of the soil pipe must be rea-sonably clean and smooth. Just push the connector spigot firmly into the soil pipe, align the pan outlet or pipe spigot withthe connector socket and push through the sealing flanges to joint.

It is important that the elastomeric and plastic sealing flanges fold inwards as shown in Fig 1 to ensure a positive seal.

Check the connector is the correct size for the pan outlet and soil pipe. Minor variations in pan spigot size can be accom-modated as the elastomeric and plastic sealing flanges ensure a positive seal. If the pan outlet is considerably under oroversized an appropriate size connector should be used.

General

Each Multikwik connector has a label showing number and size and is packed in a polythene bag with installation leafletand sachet of lubricant. As soil pipe sizes vary considerably it may sometimes be necessary to apply a liberal amount oflubricant from the sachet provided to aid assembly.

Do not use any lubricant on WC pan spigot.

Important

Connectors should not be allowed to come into contactwith mineral oil, grease, putty or any compound containingmineral oil or grease and should be protected from directsunlight and naked flames.

Note: If Multikwik connectors are to be stored where theambient temperature could exceed 95°F/35°C the advice ofthe manufacturer should be obtained.

ILLUSTRATION showing how different Multikwik Connectors canbe linked with this simple Multilink Sleeve Unit.

MULTILINK can be used to sleeve any Connector suitable for4” (102mm) soil pipe and will fit into any Connector suitable for4”-4 1/2” spigots.

‘MULTI-LINK’ SLEEVE FITTING

Multikwik Connector

Plastic andElastomeric

sealingflanges

Soil pipespigot

®

Page 24: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Soil

22

Coloursw=white

WC

Connec

tors

Size mm 100Code SWC11

A 132B 110C 81D 46

Colour w

Sraight push-fit connector

A

B

C

D

Size mm 100Code SWCB90Angle 90°

A 132B 235C 81

Colour w

90˚ Push-fit connector

A

B

C

Size mm 100Code SWC22

A 132B 115C 81D 46E 18

Colour w

Offset push-fit connector

A E

B

C

D

Size mm 90Code SWCB14Angle 14°

A 132B 61C 81D 46

Colour w

14˚ push-fit connector

A

B

C

D

Size mm 100Code SWCE33

A 81B 300C 116D 226

Colour w

Extension push-fit connector

A

B

C

D

Page 25: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

23

WasteColoursg=greyb=blackw=white

Pip

es/B

end

s

Size mm 32 40 50Code KSC1 KSC2 KSC3

A 46 53 66B 20 24 28

Colour w b w b w b

Size mm 32 40 50Code KB1 KB2 KB3Angle 88.5° 88.5° 88.5°

A 57 62 78B 18 21 28

Colour w b w b w b

Straight coupling

Bend

Pipe UPVC (70°max)

Size mm 32 40 50Code KP104S KP204S KP304S

Length m 4 4 4Colour w b w b w b

Double spigot

Pipe MUPVC (High Temp)

Size mm 32 40 50Code KP104 KP204 KP304

Length m 4 4 4Colour w w w

Double spigot

Solvent sockets

Solvent sockets

Size mm 32 40 50Code KB12 KB22 KB32Angle 45˚ 45˚ 45˚

A 29 33 42B 18 21 28

Colour w b w b w b

BendSolvent sockets

Knuckle bendSolvent sockets

Size mm 32 40 50Code KBK1 KBK2 KBK3Angle 90˚ 90˚ 90˚

A 41 65 60B 20 65 30

Colour w b w b w

A

B

A

B

A

B

A

B

Solvent weld waste systemto BS 5255: 1989

Page 26: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

WasteSolvent weld waste systemto BS 5255: 1989

24

Coloursg=greyb=blackw=white

Clip

s/Te

es/A

cces

s ca

ps

Coloursg=greyb=blackw=white

Size mm 40 50Code KXT21 KXT31Angle 88.5˚ 87.5˚

A 106 140B 62 87

Colour w w

Cross teeSolvent sockets

Size mm 32 40 50Code KT1 KT2 KT3Angle 88.5˚ 88.5˚ 88.5˚

A 92 106 135B 57 62 78

Colour w b w b w b

TeeSolvent sockets

Size mm 32 40Code KBA12 KBA22Angle 45˚ 45˚

A 24 35B 23 26

Colour w w

Bent boss connectorSpigot/solvent socket

Tee

Size mm 32 40 50Code KT11 KT21 KT31Angle 45˚ 45˚ 45˚

A 102 117 149B 66 78 100

Colour w w w

Solvent sockets

Size mm 32 40 50Code KF1 KF2 KF3

A 57 62 77B 30 30 41

Colour w b w b w b

Size mm 32 40 50Code WC3 WC4 WC5

A 57 64 80B 30 30 41

Colour w b w b w b

Pipe clip

ABS (Saddle)

A

B

A

B

A

B

A

A

B

A

B

B

UPVC (Open)

Size mm 32 40Code MFW32 MFW40Angle Adustable 0˚-90˚

Adjustable Bend

Size mm 32 40 50Code KAP1 KAP2 KAP3

A 29 33 39B 53 57 71C 8 8 8

Colour w b w b w b

Access cap

A

B

C

Page 27: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

25

WasteColoursg=greyb=blackw=white

Red

uce

rs/A

dap

tors

Solvent weld waste systemto BS 5255: 1989

Durgo automatic air admittance valve

Push-fit into ring seal BS 5255 socket; grey onlyincludes a polystyrene insulating hood

Female iron adaptorSolvent socket/BSP thread

Air amittance valve

Size mm 50Code SVD2

A 98B 82C 28

Colour g

Size mm 32 40 50Code KFA1 KFA2 KFA3

A 50 53 60B 25 25 25C 20 24 28

Colour w w w

Size mm 40Code SVM12

A 80B 63C 43

Colour w

Size mm 32 40 50CODE KEC1 KEC2 KEC3

A 86 90 82B 61 64 50C 20 23 30

Colour w w w

Expansion coupling/copper adaptor

Ring seal/solvent socket

Multi-fit to plastic pipework to BS 5255 and BS 5254 and tocopper pipework to BS 2871 (metric) and BS 659 (imperial)

Size mm 32 40 50Code KMA1 KMA2 KMA3

A 44 20 20B 47 20 24C 53 20 28

Colour w w w

Male iron adaptorSolvent solvent/BSP thread

Socket reducer

Size mm 32x21.5 40x32 50x32 50x40Code KR175 KR210 KR310 KR320

A 22 28 32 32B 20 22 28 28

Colour w w b w b w b

A

B

A

B C

A

BC

A

B

CA

BC

Includes adaptor to 50mm and 32mm

B

C

A

Page 28: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

WasteSolvent weld waste systemto BS 5255: 1989

26

Coloursg=greyb=blackw=white

Ven

ts/F

ire

Sle

eves

Size mm 50Code RV225

A 55B 18

Colour w b

Vent terminal

Vent slate capBlack rubber

Size mm 50Code SV21

A 51B 51C 68

Colour b

Size mm 50Code RS7

A 450B 450

Weathering SlateAluminium slate with rubber hood

Size mm 50Code WFC54

A 56B 43C 94D 120

Colour blue

Fire SleevesUp to 4 hour rating

Pipe WrapsUp to 4 hour rating

Size mm 50Code WFW54

A 222B 50

A

B

C

A

C D

B

A

AB

AB

B

Code UFC1Number of collars per roll

55mm, 8

Universal Fire Collar

Page 29: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

27

WasteColoursg=greyb=blackw=white

Push

-Fit

Was

te

Polypropylene push-fit waste systemto BS EN 1451-1:2000

Size mm 32 40Code WPB31 WPB41Angle 45° 45°

A 42 43B 42 43

Colour g g

BendRing seal sockets

Size mm 32 40Code KF1 KF2

A 57 62B 30 30

Colour g g

Size mm 32 40Code WC3 WC4

A 57 64B 30 30

Colour g g

Pipe clip

ABS (Saddle)

Size mm 32 40Code WPB33 WPB43Angle 88.5° 88.5°

A 60 65B 60 65

Colour g g

Knuckle bendRing seal sockets

Size mm 32 40Code WPC3 WPC4

A 82 83B 38 38

Colour g g

Straight couplingRing seal sockets

Size mm 32 40Code WPP33 WPP43

Length m 3 3Colour g g

PipeDouble spigot

Size mm 32 40Code WPB34 WPB44Angle 88.5° 88.5°

A 75 75B 37 37

Colour g g

Spigot bendSpigot/socket

A

B

A

B

A

B

A

B

A

B

A

B

UPVC (Open)

Page 30: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Waste

28

Coloursg=greyb=blackw=white

Push

-Fit

Was

tePolypropylene push-fit waste systemto BS EN 1451-1:2000

Size mm 32 40Code WPA31 WPA41

A 20 20Colour g g

Access plugPush-fit spigot

Size mm 32 40Code WPT3 WPT4Angle 88.5° 88.5°

A 105 115B 63 68

Colour g g

TeeRing seal sockets

Size mm 32 40Code WPB32 WPB42Angle 45° 45°

A 36 31B 36 32

Colour g g

Bent boss connectorSpigot/ring seal socket

Size mm 32 40Code WUM33 WUM43

A 86 86B 56 58C 24 24

Colour g g

Multi-fit straight tank connector

Including washers, sockets; fits BS 5254 or BS 5255 pipe

Size mm 40x32Code WPR43

A 45B 36

Colour g

ReducerSocket/spigot

Size mm 32 40Code WCC3 WCC4

A 75 75B 25 25

Colour w w

Multi-fit waste connectorStraight coupling; white only

Multi-fit Socket to plastics pipework BS 5255 and BS 5254 andto copper pipework to BS 2871 (metric) and BS 659 (imperial)

A

B C

A

B

A

B

A

B

A

A

B

Page 31: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

29

WasteColoursw=whitecp=chrome

plated

Was

te T

rap

s

Trap range to BS 3943: 1979Universal compression outlet traps to suit BS5255, BS 5254, BS 2871 and BS 659 pipes

Tubular swivel trapRunning ‘P’ Outlet 76 mm Water Seal

Size mm 32 40Code A10 C10

A 175 175B 68 72C 126 126

Colour w w

Bottle trap

Size mm 32 40Code SA12 SC12

A 145 150B 57 63C 57 60

Colour w w

Size mm 32 40 50Code SR10 TR10 SG10

A 125 140 160B 57 62 76C 131 146 170

Colour w w w

Tubular swivel trap‘P’ Outlet 76 mm Water Seal

Bottle trap‘P’ Outlet (anti-syphon) 76 mm Water Seal

Size mm 32 40Code A10V C10V

A 175 175B 68 72C 126 126

Colour w w

Tubular swivel trap‘S’ Outlet 76 mm Water Seal

Size mm 32 40Code SB12 SD12

A 145 150B 57 63

Colour w w

‘P’ Outlet 76 mm Water Seal

A

B C

A

B

C

Size mm 32 40Code A10AR C10AR

A 190 to 245 190 to 308B 70 72C 142 145

Colour cp cp

Chrome bottle trap‘P’ Outlet (re-sealing) 76 mm Water Seal

A

B

C

A

B B

C

A

B

C

C

B

A

Page 32: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Waste

30

Coloursw=whitecp=chrome

plated

Was

te T

rap

sTrap rangeto BS 3943: 1979

Shower trap (removable waste) 19 mm water seal

Size mm 40 40 40 40Code STW1 STW3 STW5 STW7

A 70 70 70 70B 90 90 90 90C 40 40 40 40

Flange 70 70 85 85Colour w cp w cp

Pedestal trap

Size mm 32 32Code X10 X10V

A 240 235B 45 45

Colour w w

Shower trap (removable waste) 50 mm water seal

Size mm 40 40 40 40Code STW2 STW4 STW6 STW8

A 70 70 70 70B 118 118 118 118C 63 63 63 63

Flange 70 70 85 85Colour w cp w cp

Shower trap (removable waste)

Size mm 40 40 40 40Code STW9 STW10 STW11 STW12

A 70 70 70 70B 148 148 148 148C 93 93 93 93

Flange 70 70 85 85Colour w cp w cp

80 mm water seal

A

BC

A

BC

A A

BB‘S’ Outlet 76 mm Water Seal ‘S’ Outlet (anti-syphon)

A

BC

Size mm 40Code Q31/CS

A 68B 148

Colour w

Shallow seal bathtrap19mm seal no overflow

Size mm 32 40Code BT1 BT2

A 85-140 105-160B 170 170C 100 100

Colour w w

Bidet trap19mm water seal

A

B

CA

B

Page 33: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

31

WasteColoursw=white

Was

te T

rap

sSize mm 40

Code Bathset 2A 68B 148

Colour w

Bath trap setTrap including waste, plug chain & overflow completewith removable grating (to form shower over bath)

Size mm 40Code Bathset 1

A 68B 148

Colour w

Bath trap setTrap including waste, plugchain & overflow complete

19 mm Water Seal

19 mm Water Seal

Size mm 40Code FJWF1

A 111B 175

Colour w

Manifold bath trap

Code R11 R12 R13 R15Colour w w w w

Overflow adaptors

R11: Straight connector for 19mm and 22mm pipe.R12: 4 way connector for 19mm plug supplied

with 3 plugs.R13: Adaptor to convert 19mm connections on R12

and R15 to 22mm pipe.R15: 2 way connector for 19mm pipe.

Size mm 40Code WM2.12

A 182B 150C 122

Colour w

Sink trap76mm seal.(Provision for washing or dishwashing machines)

Trap rangeto BS 3943: 1979Universal compression outlet traps to suit BS 5255, BS5254, BS 2871 and BS 659 pipes

76 mm Water Seal

R11

R12

R13

R15

A

B

A

B

A

B C

A

B

Size mm 40Code WM11.12

A 272B 122C 137

Colour w

Sink trap76mm seal. (Provision forwashing & dishwashingmachines)

A

B

C

Page 34: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

WasteTrap rangeto BS 3943: 1979

32

Colourscp=chrome

platedw=white

Was

te T

rap

s

Size mm 40Code WM3.12

A 840B 124C 715

Colour w

Washing machine trap76mm seal.(With standpipe & clip)

Size mm 40 40Code SSK2 SSK3

A 310-550 310-550B 110-290 110-290C 75 75D 130-370 130-370

Colour w w

Space saver sink trap

SSK2: 76mm seal. Double bowl (Provision for connection of washing & dishwashing machines)

SSK3: 76mm seal. Triple bowl (Provision for connection of washing & dishwashing machines)

Maximum effective lenght 18”

A

B

C

AD

B BC C

Size mm 40Code V33WM

A 210B 90

Colour w

Twin connector

Size mm 32 40Code FLEXCON-1 FLEXCON-2

Colour w w

Flexible connector

A

B

Trap bend

Size mm 32 40Code S1M T1MAngle 91.5° 91.5°

A 73 76B 57 59

Colour w cp w cp

A

B

Size mm 40Code SSK1

A 290-340B 90-280C 110-160

Colour w

Space saver sink trap76mm seal. Single bowl(Provision for connection of washing &dishwashing machines)

A

B

C

Page 35: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

33

OverflowColoursw=white

Ove

rflo

w

PVCu vent overflow pipe & fittingsto BS 6700: 1987

Size mm 21.5Code OFA21

A 47B 23C 19

Colour w

Size mm 21.5Code OP21

Length m 4Colour w

Size mm 21.5Code OSC21

A 28B 13

Colour w

Size mm 21.5Code OB90Angle 90°

A 25Colour w

Size mm 21.5Code OB45Angle 45°

A 13Colour w

Female iron adaptorPipe

Straight coupling

BendBend

Double spigot Solvent socket/BSP thread

Solvent sockets

Solvent sockets

Size mm 21.5Code OC21

A 44B 14

Colour w

Pipe clip

A

B C

A

A

BB

AA

A

Page 36: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

OverflowPVCu vent overflow pipe & fittingsto BS 6700: 1987

34

Coloursg=greyb=blackw=white

Ove

rflo

w

Size mm 21.5Code OTC21

A 50Colour w

Size mm 21.5Code OT90Angle 88.5°

A 50B 25C 21.5

Colour w

Size mm 21.5Code OBC90

A 48B 25C 13

Colour w

Size mm 21.5Code OCA21

A 39B 13

Colour w

Size mm 21.5Code OCL21

A 46Colour w

Straight tank connectorTee

Straight adaptor Bent tank connector

Cap and lining

Solvent sockets Solvent socket/BSP thread including polyethylenewashers

Solvent socket/BSP thread including polyethylenewashers

Solvent socket/spigot to 22mm

Spigot/BSP nut

A

A

A

B

B

C

A

A

B

C

Page 37: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

35

Coloursg=greyb=blackw=white

Acc

esso

ries

Size mm 82 110 160Code SR31T SR41T SR61T

Size mm 32 40 50Rubber Inlet

Code RW1 RW2 RW3

Rubber Outlet Olive Code RWM1 RWM2 RWM3

Plastic Washer Code PWM1 PWM2 PWM3

Solvent cement

‘T’ rings

Silicone lubricant

Trap Washers

New universal ‘T’ seal

For jointing PVCu/PVCmu and ABS pipes and fittings.Conforms to BS 6209: 1982. All cans and tubes carrydate of manufacture and should be used within twelvemonths of this date. Polypropylene cannot be solventwelded.

For boss branches and ABS/PVCu waste

*This ‘T’ ring cannot be used in 50mm boss connectorSA420 which uses SSR3. SA420 can only be fitted toBS 5255 pipe.

Size ml 55 85 115 250 250Code KS2 KS85 KS4 KS10 KS250

tube can & brush tube can & brush can & brush

Size mm 32 40 50Code SR1T SR2T SR3T*

Size gms 800Code LUB800

tub

Snap capFor 110mm fittings

Size mm 110 160Code SNC4 SNC6

Colour b g g

Size mm 32 40 50Code S8M T8M Z8M

Trap Outlet Nuts

Accessories& Spares

Page 38: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

TechnicalInformation

36

Coloursg=greyb=blackw=white

Sin

gle

Sta

ck S

yste

m

Single Dwellings up to 3 Storeys 450mm

Multi-Storey up to 5 Storeys 750mm

Multi-Storey over 5 Storeys Ground floor connections should dischargedirect to drain or into their own stack

Multi-Storey over 20 Storeys Ground floor and first floor should dischargeinto their own stack

B

Branch connections to stacks

Table 1

Sanitary Pipework Design

Single stack system incorporating the collar boss

SV42 vent terminal

SV43 weathering collar

SC45 barrelpipe clip

SY400 equal branch

SC12tubular swivel trap

MK31/90WC connector

KBA12KT21 tee

SCB41collar boss

SWS41boss branch

SFS41 accessUB490 long radus bend

KB22 bend

basin

bath

Bathset 1bath trapand overflow

Four boss upstands moulded at 90˚ to the collarboss have been designed to accept the range ofboss adaptors to allow 32, 40 and 50 mm smalldiameter waste connections, high under theswept entry of the WC branch connection to thevertical stack.

A10Vanti-syphonbottle trap

WC

A

The following information has been taken from the BuildingRegulations Approved Documents and from the Code of Practicefor sanitary pipework BSEN 12056:2000, Parts 1 to 5. It is intendedas a brief digest of the relevant provisions, and is a guidance as tothe use and installation of MFP Soil and Waste drainage products.

KeyA. Small similar sized connections not exceed-

ing 65mm and not directly opposite shouldbe offset by 110mm on a 100mm diameterstack and 250mm on a 150mm stack.

B. Angled connections or 50mm diameterparallel junction where a waste branchdirectly opposite a WC would enter thestack within 200mm below the WC con-nection centre line.

Building Regulations and Codeof Practice Requirements

The distance between the lowestbranch connection to thedischarge stack and the invert ofthe bend off the foot of the stackshould not be less than shown onthe table opposite.

A branch pipe should not discharge into a stack in a waywhich could cause cross flow intoany other branch pipe.

The Collar boss has been developedprecisely to facilitate multi-point con-nections in the area of the WC to thestack, eradicating the danger of crossflow even within the 200mm danger zone.

The collar boss has the added advan-tage of allowing such connections frombaths and showers to connect into thestack above floor level at four pointsaround its circumference.

Discharge from the WC is preventedfrom making contact with the smallerdiameter pipework and waste waterfrom the bath spills out of the annularchamber. This flow pattern occurswithout interruption to merge withother discharges passing down the 110mmvertical stack.

The wide range of MFP componentsused in the construction of single stacksystems have been designed toensure that simple ring seal joints areprimarily employed on site – this givesa completely flexible system providingfor maximum ease of installation.

Page 39: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

37

TechnicalInformation

Coloursg=greyb=blackw=white

Ven

tila

tion

Underground drainage systems are traditionally ventilatedby ventilating stacks that terminate in an end open to theatmosphere. The Durgo valve was designed to reduce thenumber of ventilating pipes and roof penetrations indomestic, institutional and commercial sanitary plumbingsystems without affecting drainage performance.

Durgo valves are supplied complete to suit 50mm, 82mmand 110mm pipework suitable for use in above groundsanitary pipework system designed in accordance withBSEN 12056:2000, Parts 1 to 5. When the system is sub-ject to negative pressure the valve diaphragm lifts fromits seating and allows air to be drawn into the pipework.

If positive pressure occurs the diaphragm returns to theclosed position to prevent foul air entering the building.

Durgo valves should always be fitted in a vertical positionabove the flood level of the highest sanitary appliance.They should be installed within the building in a non-habitable location, e.g. duct or roof or ceiling space,where there is no risk of freezing and where they areaccessible for maintenance.

Durgo valves are supplied complete with insulatingcover which should be left in position after installation,for protection.

The ventilation of a discharge stack tothe open air is required to limit thepressure fluctuations within the sys-tem and thereby prevents water sealsin traps from being drawn and foul airfrom entering the building.

Where separate ventilation of branchpipes is not provided, the length andslope of the branch discharge pipesshould not exceed those shown in theopposite diagram. If the values in thisdiagram are exceeded, the branch pipeshould be ventilated by a branch venti-lating pipe or by an anti-syphon trap.

Ventilation

Automatic Air Admittance Valves

When the sanitary pipework system issubject to negative pressure the valvediaphragm lifts from the seating toallow air to be drawn into the pipework.

The valve in a closed positionunder normal conditions.

rubber seal

valve body

rubber seal

valve body

rubber seal

If positive pressure occures the valvediaphragm returns to the closed posi-tion to prevent foul air from escaping.

Operation of Durgo Valve

3 m max. for 40 mm pipe* 4 m max. for 50 mm pipe

6 m max. single WC

slope 9 mm/m min.slope between 18 to 90 mm/m

slope between 18 to 90 mm/m slope (see graph)

sink wash basin

WC

bath

1.7 m max. for 32 mm pipe* 3 m max. for 40 mm pipe

Note: *Where the larger branch pipesizes are used the diameter of thetrap is not increased but the tail ofthe trap should be lengthened by 50mm before increasing the diameter.

82 mm50 mm

SE300pipe socket

SE400pipe socket

WAC51/KEC3pipe socket

110 mm

Unvented branch connections to stack

Design curve for 32 mm wash basin

3 m max. for 40 mm pipe* 4 m max. for 50 mm pipe

Typical connection to 50, 82 and 100 mm ‘T’ seal socket

Page 40: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

TechnicalInformation

38

Coloursg=greyb=blackw=white

Ven

tila

tion

Stack vents should terminate atsuch a height and position that foulair does not cause a nuisance orhealth hazard. In general, this isachieved if the vent stack is notless than 900mm above the head ofany window or other opening into abuilding within a horizontal distance of 3m. Stack should bepositioned away from parapets andcorners of buildings.

The bend at the base of a dischargestack should be a large radius bendor, alternatively, two 45° large radiusbends should be used.

A stub stack consists of a short110mm discharge stack with aclosed top, preferably with anaccess fitting, which can be usedto connect a group of ground floorappliances to a drain, provided thecentre line of the WC branch is notmore than 1.5m, and the centre lineof the topmost connection is notmore than 2.5m above the invertlevel of the drain or branch discharge pipe. See diagram opposite.

Stub Stack

Base of Stack

Bend and branch connections at base of discharge stacks

i) Preferable arrangement ii) Alternative arrangement

L ≥ 450 mm (for single houses up to three storeys high)or L ≥ 740 mm (for multi-storey systems up to five storeys high)or L≥ one storey height (for multi-storey systems higher than five storeys) i.e. no connections on ground floor levelR is as large as possible (twice internal diameter (ID x 2)

Termination of Vent Stack

Termination of stack vents and ventilating stacks

Discharge from stub stacks

Page 41: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

39

TechnicalInformation

Coloursg=greyb=blackw=white

Pip

ework

Siz

ing

BS 5572 and Building RegulationsTechnical Document H require that thecapacity of the sanitary system should belarge enough to carry the expected flowat any point. The flow depends on thetype, number and grouping of appliancesand on the frequency of use of thoseappliances.

The Discharge Unit Method detailed inBSEN 12056:2000, Parts 1 to 5 pro-vides a system of determining the dis-charge stack and branch discharge pipesizes required where a large number ofappliances discharge into individualstacks. The value for each appliance isestablished, depending on its frequency of use. The unit values for allsanitary appliances discharging into thestack or branch discharge pipe shouldbe added and the appropriate dischargepipe size chosen from the pipe sizingtables following.

Single WC’s: 100mm WC branches do not normallyrequire venting whatever the length or the number ofbends included in the run. Bends, however, should haveas large a radius as possible to prevent blockage.

Range of WC’s: 100mm branch pipes serving rangesof WC’s will usually not need branch venting. Lengthand slope are not critical but venting may be necessarywhere there are several bends in the branch pipe ormore than eight WC’s are connected.

Discharge Unit Values and Flow Rates for Common AppliancesType of Appliance Minimum Interval Discharge Units

of DischargeWC with 9 litres high 20 7or low level cistern 10 14

5 27WC with 7.5 litres 20 6high or low level cistern 10 12

5 24WC with 7.5 litres 20 4close coupled cistern 10 7

5 14Urinal add 0.15 l/s per unitWashbasin 20 1

10 35 5

Spray Tap Basin add 0.06 l/s per tapBath 75 (domestic) 7

30 (congested) 17Shower add 0.15 l/s per headSink 20 7

10 185 26

Automatic Washing 250 (domestic) 3Machine 4 (commercial/congested) 18One group consisting of: one WC (7.5L), one bath, 14one or two basins, one sink and a washing machine

Maximum Capacity and Number of DischargeUnits for Vertical StacksSize mm Approximate Capacity Approximate number

of Stack L/S of discharge Units50 1.2 10 (no WC’s)75 3.4 200100 7.2 750150 21.7 5500

General Guide for the Size of VentilatingPipes and StacksSize of Branch Discharge Size of Branch Ventilating Pipe or Discharge Stack D Pipe or Stack Less than 75mm 2/3 D (25mm min.)75mm and above 1/2 D

Maximum Number of Discharge Units Allowedon Branch Discharge Pipes

Discharge UnitsSize mm Gradient 1/2° Gradient 11/4° Gradient 21/2°

9mm/M 22mm/M 45mm/M32 1 140 2 850 10 2675 100 230100 230 430 1050150 2000 3500 7500

Note 1: Maximum number of discharge units permitted for a 150mm verti-cal stack is 5500

Note 2: Discharge pipes sized in this way give the minimum size necessaryto carry the expected flow load

Note 3: Ventilating pipes may be required and sizes are shown in table below.

Pipe Sizing Using Discharge Unit Method

* some proportion of the total may be assumed to be in simultaneous operation if considered appropriate Note: Unless otherwise stated, the frequencies given above represent the following

20 min corresponds to peak domestic use, 10 min corresponds to peak commercial use, 15 min corresponds to congested use in public toilets, schools etc.

Note: Ventilating stacks may be required and sizes are shown in table right.

Page 42: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

TechnicalInformation

40

Coloursg=greyb=blackw=white

Sys

tem

Connec

tions

System Connections

Boss connectionsThree types of boss fittings are available as alternative methods of connecting small diameter sanitarypipework to the vertical stack.

Bossed UpstandsBoss Branch UpstandsStrap-on Boss

Bossed upstandsSome fittings in the 110 mm range aresupplied with single boss connections at 87.5°, complete withprelocated multi-fit ‘T’ seals in eachsmall diameter socket to receive 32mm and 40 mm PVCu and polypropylene small diameter waste pipes.

Boss branchesPlain boss upstands are moulded at 90°to the axis of the main body. Theseshort sockets are of the same diameteracross the range of 82, 110 and 160mm fittings, designed for conversion to32, 40 and 50 mm pipe by using theappropriate mult-fit boss connector.

Boss branches allow multi-point con-nection of branch pipes to the centralstack via preformed boss upstands asdetailed on pages 6-9. The most versatile branch for bathroom design is the uPVC five bossbranch used in conjunction with theKBK35, KBK25 knuckle bends. Thereare four different permitted connectionsinto the branch’s side bosses, as illus-trated opposite. The rear boss may beused with any of these combinations asrequired, but staggered connectionsinto the branch are not permitted.

Strap-on BossThe strap-on boss allows connection ofsmall diameter pipework to the stack atany point (subject to BuildingRegulations requirements). The strap-on boss has a multi-fit ring seal fordirect connection to 32, 40 or 50 mmPVCu, polypropylene pipework.

Branch connections to stacks

Note: In cases where boss sockets are supplied unperforated, these may be opened using a standard51 mm hole cutter or, alternatively, by drilling a number of small interconnecting holes aroundthe circumference and removing rough edges with a half round file.

SW415/SW41ring sealboss branch32 or 40 mm pipe

SWS4150/410/420strap on boss32, 40 or 50 mm pipe

SWS41/415Solvent sockeyboss branch32 or 40 mm pipe

SW40ring sealboss branch32, 40 or 50 mm pipe

Branch connections to stacks

Page 43: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

41

TechnicalInformation

Coloursg=greyb=blackw=white

Fir

e P

rote

ctio

nThe Marley Pipe Wrap consists of a flexible intumescentstrip sealed in a protective sleeve, making the PipeWraps quick and easy to install.Wall Construction. The Pipe Wrap can be used with-in brick, block or concrete walls to provide up to 4hours fire resistance. Single or double Pipe Wraps maybe required, depending on the wall thickness and fire protection required.

Floor Construction. For vertical pipes through floors,Pipe Wraps can be easily installed within the depth ofthe floor slab, providing up to four hours’ fire resistance,dependant on pipe size and method of installation.

The Marley Fire Sleeve consists of two half shells ofpowder coated sheet steel filled with a heat reactiveintumescent material and joined around the pipe by side clasps.In the event of a fire, the intumescent material expandsinwards blocking off the pipe and providing an effectiveseal against flames and hot gases, so maintaining compartment walls and floors.Where a pipe penetrates through a wall construction theFire Sleeve should be fixed to the wall on the side atrisk from the fire attack. Where the direction of fire riskis not known, a Fire Sleeve should be fixed to both sidesof the wall. Where the pipe penetrates through a floor construction, the Fire Sleeve should be fixed to theunderside only.Fire Sleeves are supplied complete with four masonryanchor bolts for fixing direct to brick, block or concretewalls. Where access is restricted, it is acceptable to useonly three anchor bolts.Fire Sleeves are normally fixed to relatively smooth surfaces. However, where the surface is very rough, it is possible to improve the smoke tightness of the seal bywelding it onto a bead of Intumescent Gap Mastic (SFM 400).

Marley Fire Protection Products stop the spread of fire via PVCu pipework passing through fire compartment walls andfloors, providing up to four hours fire resistance. Marley fire protection products have been fully tested at independentlaboratories to BS476: part 20: 1987, for up to 4 hours fire resistance.

Leaflet with further information and details available on request.

Fire Protection Range

Up to 4 hour rating

Marley Pipe Wrap

Wall Seals (forthickness up to150mm)

CementSurround Wall Seals (for

thickness over150mm)

Marley Pipe Wrap

Up to 4 hour rating

Universal Fire CollarThe UFC1 universal fire collar provides a new approach tothe traditional fire sleeve. The product comes supplied asan Intumescent, metal backed roll which can be cut to formany diameter fire collar from 50mm up to 160mm. Thisgives the installer the flexibility of keeping just one productto meet all pipe diameter requirements. The universal firecollar is supplied in a dispensing carton, including a tapemeasure, knife and fixings to allow surface mounting.

The table below outlines the fire rating for the UniversalFire Collar when used in either wall or floor.

Pipe outside

diameter

Wall or Floor Pipe Diameter Fire RatingWall Up to 110mm 120minsFloor Up to 110mm 240minsFloor 110mm & 160mm 180mins

Page 44: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

42

TechnicalInformation

Pip

e S

up

port

This system comprises the uPVCbarrel pipe clip and the PVCcoated mild steel socket clip and

is generally used with the largerdiameters (82-160mm) sanitarypipework (for full componentdetials, see page 11).

The barrel pipe clip is suitable foruse as an intermediate guidebracket between anchor points,allowing the pipe to move withoutdistortion as it responds to temperature changes. The socketclip is available as a supportingmetal anchor bracket. The metalsocket clip may be adapted to suitthe outside diameter of the pipe byinserting a barrel clip collar. Alljoint ring sockets have an anchorrib so that clips may be securelyand accurately fitted into place(see opposite).

Table opposite indicates the maximum distances between pipesupports, taking account of thethermal movement of plastic.

The MFP Pipe Support System hasbeen developed to meet the require-ments of suspended sanitary pipework.It is suitable for internal use only.

Three methods of supporting low gra-dient PVCu pipes have been devel-oped to provide a robust, lightweightsystem suitable for most situations.

1. Single supportSuitable for pipework from 32 mmto 160 mm diameters within 500mm of the floor soffit (600 mm withside bracing).

2. Continuous channel supportSuitable for exposed pipework from32 mm to 160 mm within 750 mmof the floor soffit (or 1.0 m withside bracing).

2. 32 mm, 40 mm and 50 mm pipeworkis installed as shown in methods 1.and 2. without additional anglebrace connections.

Pipe clip system

Nominal pipe Horizontal Vertical size mm support (M) support (M)

32 0.50 1.2040 0.50 1.2050 0.60 1.2082 0.90 1.80110 0.90 1.80160 1.20 1.80200 1.20 1.80250 1.20 1.80

Anchor brackets required at 3M centres.

Branch connections to stacks

SC621barrel pipe clipcollar

SC35/45barrel pipe clip

SC31/41/61socket pipe clip

SC31/41/61socket pipe clip

Pipe support system

1. Single support

2. Continuous channel support

Page 45: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

43

TechnicalInformation

Pip

e S

up

port

Pipe support system

3. Double support

Double support large diameters 4. Side bracing

Vertical Pipes

Branches

Vertical pipesA change in direction from verticalto low gradient pipework should beachieved by using two 45° bendsor a 90° long radius bend. Theseshould be fully supported.

A change of direction from low gradient to vertical pipeworkshould be achieved by using a 45°branch and an adjustable bend.

Small diameter connectionConnections for small diameterpipework should be 45°, andwhere possible dipped into themain run. The SWS3135 32 mmand SWS4135 40 mm BossBranch give the required angle.

Access pointsThe system design should incorporate access points to allowunobstructed access for testingand maintenance. The pipe supportsystem can also be used to construct support frames for vertical pipework in enclosedducts. Other services may also besecured to these frames.

Components in pipe support system are covered by RegisteredDesign No. 967040 and patentapplication No. 36610-73.

3. Double supportSuitable for pipework from 82mm to 250 mm within 1.0 m ofthe floor soffit (1.2 m with sidebracing). Larger 200 mm and250 mm diameters require theuse of channel strip angles(JCA1) and 90° angle cleats(JAC1) to attach the anchorbracket and angle brace to thefloor soffit.

4. Side bracingUse of side bracing increasesthe maximum distance of thepipework from the floor soffit.

4. On long runs with no horizontalbranch connection, side bracingis required at 6 m centres.

Page 46: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

44

TechnicalInformation

SV42 vent terminal

SV43 weathering collar

SC45 barrelpipe clip

SY400 equal branch

basin

bath

Four boss upstands moulded at 90˚ to the collarboss have been designed to accept the rangeof boss adaptors to allow 32, 40 and 50 mmsmall diameter waste connections, high underthe swept entry of the WC branch connectionto the vertical stack.

A10V anti-syphon bottle trapWC

Single stack system incorporating the collar boss

Bathset 1 bath trap and overflowMK31/90

WC connectorKBA12KT21 tee

UB490 long radus bend

KB22 bend SC12 tubular swivel trap

SFS41 access

SWS41 bossbranch

SCB41 collar boss

Page 47: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Notes

Page 48: Soil & Waste Systems - MFPmfp.ie/wp-content/uploads/2016/11/SOIL_WASTE.pdf · Soil & Waste Systems CI/SfB July 2003 (52.6) In6. ... BS EN 12056: 2000, ... to BS EN 1329-1:2000 4 Colours

Leaders in PVCu building products

MFP Sales Ltd.Lucan, Co. Dublin, Ireland. Tel: +353 (0)1 630 2500 Sales Hotline:+353 (0)1 630 2600

Fax: +353 (0)1 628 1119Dargan Road, Belfast BT3 9JU. Tel: 028 9077 4790 Fax: 028 9077 4716Website: www.mfp.ie Email: [email protected]


Recommended