April 2009 NABCEP Study Guide Questions 1-29 SolPowerPeople, Inc. Austin, TX March 8, 2012
Transcript
Page 1: #Solar mooc 2009 nabcep study guide solutions 1-29

April 2009 NABCEP Study

Guide Questions 1-29 SolPowerPeople, Inc.

Austin, TX

March 8, 2012

Page 2: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 1

Page 3: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 1

­  1. b. “as required by OSHA Subpart E.”

­  Seems to be an error in this answer. NABCEP indicates subpart “E”. OSHA indicates subpart “M”.

­  1926.501(b)(1) ­  "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface)

with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Page 4: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 1

Page 5: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 2

Page 6: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 2

­  2. b. reference OSHA Subpart E.

Page 7: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 3

Page 8: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 3

­  3. A. “See section 3.1.2” (of NABCEP Study Guide)

­  “The severity of the shock depends on the path of current flow through the body, the amount of current, and the duration of the exposure”

Page 9: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 4

Page 10: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 4

­  4. A. “See section 3.1.2” (of NABCEP Study Guide)

­  “Currents above 10 mA can paralyze or “freeze” muscles.”

Page 11: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 5

Page 12: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 5

­  5. D. “See section 3.1.2” (of NABCEP Study Guide)

­  “Currents of more than 75 mA ac can cause a rapid, ineffective heartbeat, and can result in death in minutes unless a defibrillator is used.”

Page 13: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 6

Page 14: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 6

­  6. A. “See section 3.1.2”

­  “Lockout and tagging is used to prevent unknowing individuals from energizing electrical circuits while they are being serviced or maintained.”

Page 15: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 7

Page 16: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 7

­  7. B. “See section 3.1.3” (of NABCEP Study Guide)

­  “Consequently, OSHA requires that fall protection be used for walkways and ramps, holes and excavations, roofs, and wall openings where an employee or worker can fall 6 feet or more.”

Page 17: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 8

Page 18: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 8

­  8. D. “See section 3.1.3” (of NABCEP Study Guide)

­  “Guardrails used to protect open-sided floors and platforms must have top rails between 39 and 45 inches tall, a mid rail, and toeboards at least 3-1/2 inches high.”

Page 19: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 9

Page 20: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 9

­  9. B. “See section 3.1.3”

­  “Guardrails used to protect open-sided floors and platforms must have top rails between 39 and 45 inches tall, a mid rail, and toeboards at least 3-1/2 inches high.”

Page 21: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 10

Page 22: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 10

­  10. D. “See section 3.1.3”

­  “Safety nets must be deployed no further than 30 feet below where work is performed, preferably closer.”

Page 23: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 11

Page 24: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 11

­  11. C. “See section 3.1.4”

­  “OSHA requires that a stairway or ladder be used at points of access where there is an elevation break of 19 inches or more on a jobsite.”

Page 25: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 12

Page 26: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 12

­  12. A. “See section 3.1.4”

­  “Stairways with four or more risers, or higher than 30 inches, must be equipped with at least one handrail, capable of withstanding a force of 200 pounds.”

Page 27: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 13

Page 28: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 13

­  13. B. “See section 3.1.4”

­  “Stairways with four or more risers, or higher than 30 inches, must be equipped with at least one handrail, capable of withstanding a force of 200 pounds.”

Page 29: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 14

Page 30: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 14

­  14. D. “See section 3.1.4”

­  “Stairs must be installed between 30 and 50 degrees, must have uniform riser height and tread depth, with less than a 1/4-inch variation.”

Page 31: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 15

Page 32: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 15

­  15. B. “See section 3.1.4”

­  “Stairways landings must be at least 30 inches deep and 22 inches wide at every 12 feet or less of vertical rise.”

Page 33: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 16

Page 34: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 16

­  16. B. “See section 3.1.4”

­  “Non-self-supporting ladders (those that lean against a wall or other support) must be positioned at an angle where the horizontal distance from the top support to the foot of the ladder is 1/4 the working length of the ladder.”

­  The working height is 20 feet. 1/4th of 20 is 5 feet.

Page 35: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 17

Page 36: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 17

L = (12)2 + (3)2 +3

L = 144+ 9 +3

L = 153 +3L =12.4+3L =15.4 feet

Page 37: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 17

12 feet

3 feet (i.e. ¼ of 12 as required by OSHA)

Unknown length

3 feet as required by OSHA

3.1.4 “When using a portable ladder for access to an upper landing surface, the side rails must extend at least 3 feet above the upper landing surface.”

L = (12)2 + (3)2 +3

L = 144+ 9 +3

L = 153 +3L =12.4+3L =15.4 feet

Page 38: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 18

Page 39: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 18

­  18. D. “See section 3.1.4” If using ladders where the employee or the ladder could contact exposed energized electrical equipment, such as transformers or overhead services, ladders must have nonconductive side rails such as wood or fiberglass.

Page 40: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 19

Page 41: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 19

­  19. D. “See section 3.1.6”

­  “Class B hardhats are intended for electrical and utility work, and protect against falling objects, as well as high-voltage shock and burns.” from NABCEP Study Guide.

Page 42: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 19

­  WRONG!: Hard hats are classified based on ANSI Z89.1. The 1986 revision had a Class B classification for high voltage. This classification changed in 1997 to Classes G & E.

Page 43: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 19

Page 44: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 20

Page 45: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 20

­  20. D. “See section 3.1.6” (of NABCEP Study Guide)

­  “Employee responsibilities include using PPE in accordance with training received and other instructions, and inspecting daily and maintaining in a clean and reliable condition.”

Page 46: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 21

Page 47: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 21

­  21. D. “See section 3.1.6”

­  “Eye protection must be provided to protect against hazards such as dust and other flying particles, corrosive gases, vapors, and liquids, and welding operations.”

Page 48: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 22

Note: NABCEP loves this question!

Page 49: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 22

­  22. C.

­  C is the best answer because (a) is not at the level of the workers, (b) may be distracted, and d is not at the level of the workers and not in communication with them while they work.

Page 50: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 22

"Safety monitoring systems." Safety monitoring systems [See 1926.501(b)(10) and 1926.502(k)] and their use shall comply with the following provisions: 1926.502(h)(1) The employer shall designate a competent person to monitor the safety of other employees and the employer shall ensure that the safety monitor complies with the following requirements: 1926.502(h)(1)(i) The safety monitor shall be competent to recognize fall hazards; ..1926.502(h)(1)(ii) 1926.502(h)(1)(ii) The safety monitor shall warn the employee when it appears that the employee is unaware of a fall hazard or is acting in an unsafe manner; 1926.502(h)(1)(iii) The safety monitor shall be on the same walking/working surface and within visual sighting distance of the employee being monitored; 1926.502(h)(1)(iv) The safety monitor shall be close enough to communicate orally with the employee; and 1926.502(h)(1)(v) The safety monitor shall not have other responsibilities which could take the monitor's attention from the monitoring function.

Page 51: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 23

Page 52: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 23

­  23. B. The module and wiring can withstand short-circuit current of the module, even if modules are connected in series or parallel. (Wiring must be sized accordingly.)

Page 53: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 23 ­  Consider this. Modules have a nameplate rating for Isc

(short-circuit current) under STC (standard test conditions) which is an irradiance of 1,000 watts per square meter

Page 54: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 23

­  Now consider that all modules have a “series fuse rating” which is an indication of the ampacity of the device, as in how much current the device can handle.

Page 55: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 23

­  This implies that in order for the module to produce current greater than the ampacity of the module itself, it would been to be exposed to an irradiance level of 3,200 watts per square meter which you would never see with terrestrial irradiation.

Isc@1,000watts /m2 = 6.2520amps / 6.25amps = 3.23.2×1,000W /m2 = 3,200W /m2

Page 56: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 24

Page 57: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 24

­  24. C. Multiply the open-circuit voltage by 1.18. B

­  Be sure to use the −20°C correction factor from NEC Table 690.7.

Page 58: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 24

Page 59: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 25

Page 60: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 25

­  25. B. The GFP is designed to provide fire protection. The GFCI protects people from shock.

Page 61: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 25

­ From 3.5.4.1: The 2008 NEC, in article 690.5 requires that all grounded PV arrays must incorporate a ground-fault protection device to reduce fire hazards.

Page 62: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 26

Page 63: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 26

­  26. C. The module maximum power voltage decreases at the rate of -0.5%/°C (rule of thumb) for module temperatures above 25°C.

­  Hence, at 60°C, the module voltage will have decreased by 0.5×(60−25) = 17.5%, resulting in Vmp = 14.1 V.

Page 64: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 27

Page 65: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 27

­  27. A. See NEC 480.9(A). Note that option (c) represents an implementation of (a), but is not exact NEC wording.

Page 66: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 27

Page 67: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 28

Page 68: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 28

­  28. C. “See instructions from equipment and battery manufacturers.” ­  “When vented lead-acid batteries are used, they should not be located

beneath any electronic components. The corrosive vapors from the batteries can degrade the circuitry in the electronic equipment causing premature failures.”

­  The answer implies all of the other battery types listed produced outgassing that can damage electronic equipment.

Page 69: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 29

Page 70: #Solar mooc 2009 nabcep study guide solutions 1-29

Problem 29

­  29. B. See any instructions from manufacturers of storage batteries or equipment that uses storage batteries.

­  From section 3.1.9: “If batteries are used outdoors in cold climates, the electrolyte freezing temperature increases as the batteries discharge. If the electrolyte freezes, DO NOT CHARGE THE BATTERY. Let it thaw slowly in a place where, if it should rupture, the electrolyte will be contained. Do not attempt to accelerate the thawing process with anything that might be capable of igniting any gases that may be liberated.”