+ All Categories
Home > Documents > Solutra n hemo l u t i o n Solutra n hemo BLOOD bags y o u ...€¦ · buffy-coat depleted red...

Solutra n hemo l u t i o n Solutra n hemo BLOOD bags y o u ...€¦ · buffy-coat depleted red...

Date post: 10-Dec-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
Via Della Piana 1 Tel. +39 0342 77 10 70 23030 Lovero V. (SO) - Italy Fax. +39 0342 77 10 71 meditaliasrl.com [email protected] Via Della Piana 1 Tel. +39 0342 77 10 70 23030 Lovero V. (SO) - Italy Fax. +39 0342 77 10 71 meditaliasrl.com [email protected] For human blood and blood components Summary table of performances of MEDITALIA blood bags for the collection of 450 ml of blood ITEM TEST RESULT Resistance to centrifugation (5,000 g x 10 min) No leakage, no distortion Resistance to stretch (20 N for 5 seconds) No breakage, no deterioration Leakage (67 kPa for 10 min) No loss in walls, seals and joints Emptying under pressure (40 kPa internal pressure) Completed in 40 sec (requirement <2 min) Speed of filling (9.3 kPa pressure) Completed in 2.5 min (requirement <8 min) Resistance to temperature variations (from -80 to +50 °C) Full compliance with tests for resistance to centrifugation, resistance to stretch, leakage, emptying under pressure and speed of filling Transparency (opalescent solution with absorbance = 0.4) Easy appreciation of turbidity Red cell hemolysis at the end of storage (42 days) ²0.3%; n=3 Optimal pH of platelets after 7 days of storage 6.88 - 7.12; n=3 Solutran ® hemo BLOOD bags by Meditalia your solution Solutran ® hemo BLOOD bags by Meditalia your solution
Transcript
Page 1: Solutra n hemo l u t i o n Solutra n hemo BLOOD bags y o u ...€¦ · buffy-coat depleted red blood cells, plasma and buffy-coat (which can be used to prepare platelets ) All configurations

Via Della Piana 1 Tel. +39 0342 77 10 7023030 Lovero V. (SO) - Italy Fax. +39 0342 77 10 71meditaliasrl.com [email protected]

Via Della Piana 1 Tel. +39 0342 77 10 7023030 Lovero V. (SO) - Italy Fax. +39 0342 77 10 71meditaliasrl.com [email protected]

For human blood and blood components

Summary table of performances of MEDITALIA blood bagsfor the collection of 450ml of blood

ITEM TEST RESULTResistance to centrifugation(5,000 g x 10 min)

No leakage, no distortion

Resistance to stretch (20 N for 5 seconds)

No breakage, no deterioration

Leakage (67 kPa for 10 min)

No loss in walls, seals and joints

Emptying under pressure (40 kPa internal pressure)

Completed in 40 sec (requirement <2 min)

Speed of filling (9.3 kPa pressure)

Completed in 2.5 min (requirement <8 min)

Resistance to temperaturevariations (from -80 to +50 °C)

Full compliance with tests for resistance to centrifugation,resistance to stretch, leakage, emptying under pressure andspeed of filling

Transparency (opalescentsolution with absorbance = 0.4)

Easy appreciation of turbidity

Red cell hemolysis at the end of storage (42 days)

²0.3%; n=3

Optimal pH of plateletsafter 7 days of storage

6.88 - 7.12; n=3

Solutran®hemoBLOOD bags

by Meditalia

your solution Solutran®hemoBLOOD bags

by Meditalia

your solution

Page 2: Solutra n hemo l u t i o n Solutra n hemo BLOOD bags y o u ...€¦ · buffy-coat depleted red blood cells, plasma and buffy-coat (which can be used to prepare platelets ) All configurations

Blood donor needleand needle protector• High quality and consistent performanceJapanese needle technology.

• Silicon coating on internal and externalsurface of cannula.

• Protection of the needle to reduce the riskof needle stick injury.

• Flexible blood collection tubes• Efficient transfer of blood componentsinto the different containers

Break off part• Easy clip-tip fracture

Color coded clampAllows the identification ofthe different kind of clamp.

Non reopening clampSafety system toguarantee the isolationof the sampling bagafter filling.

Safety sampling bagUseful container for thecollection of contaminationfree pre-donation samplingfor laboratory testing.

Vacuum bloodconnector needle• Reduces potentialexposure of thesampling needleduring the handling.

• The safety hingedcover isolates thesampling needle fromdirect exposure.

• Optimal flexibility andtransparency of theplastic material

• Excellent handlingcharacteristics.

Optimal gas permeabilityAverage oxygen permeability of Solutran Hemo® plastic bag forplatelet storage,O2 TR = 680 cc/m2•24h•atm; CO2 TR = 10205 cc/m2•24h•atm. Test carried out in compliance with the European Pharmacopoeia.

Label• PVC material• Tamper proof• Convenient to write on

Set for human blood and blood components collection

Single blood bagcontaining CPDA-1

Double blood bagcontaining CPDA-1

It can be used to prepare red blood cells and plasma

Triple blood bagcontaining CPD and SAG-MIt can be used to prepare red

blood cells,plasma and platelets

Quadruple blood bagcontaining CPD and SAG-M

It can be used to preparebuffy-coat depleted red blood cells,

plasma and buffy-coat (which can be used

to prepare platelets)

All configurations are available:- with or without a 40ml pre-donation

“safety sampling bag”- with or without needle protector

Content:ml 63 CPDA-1

Content:ml 63 CPDA-1

Content:ml 63 CPD

Content:ml 63 CPD

Emptytransfer bag

Emptytransfer bag

Content:ml 100 SAG-M

Emptytransfer bag

Emptytransfer bag

Content:ml 100 SAG-M

Solutran®hemoBLOOD bags

by Meditalia

your solution

CPDA-1: citrate, phosphate, dextrose, adenineCPD: citrate, phosphate, dextroseSAG-M: sucrose, adenine, glucose, mannitol


Recommended