Micrologix 1000 Features Preconfigured 1K programming and data memory — help ease configuration (bit, integer, timers, counters, etc) Fast processing — allows for typical throughput time of 1.5 ms for a 500- instruction program Built-in EEPROM memory — retains all of your ladder logic and data if the controller loses power, eliminating the need for battery back-up or separate memory module RS-232 communication channel — allows for simple connectivity to a personal computer for program upload, download and monitoring using multiple protocols, including DF1 Full Duplex RTU slave protocol support — use DF1 Half-Duplex Slave, which allows up to 254 notes to communicate with a single master using radio modems, leased-line modems or satellite uplinks Product Design The MicroLogix 1000 controller contains the power supply, processor, and all its I/O circuits packaged in a single unit. Four I/O sizes (10, 16, 25, and 32) cover many applications.
Transcript
Page 1: Some stuff  Regarding PLC Micrologix 1000 & 1100

Micrologix 1000Features

Preconfigured 1K programming and data memory — help ease configuration (bit, integer, timers, counters, etc)

Fast processing — allows for typical throughput time of 1.5 ms for a 500-instruction program

Built-in EEPROM memory — retains all of your ladder logic and data if the controller loses power, eliminating the need for battery back-up or separate memory module

RS-232 communication channel — allows for simple connectivity to a personal computer for program upload, download and monitoring using multiple protocols, including DF1 Full Duplex

RTU slave protocol support — use DF1 Half-Duplex Slave, which allows up to 254 notes to communicate with a single master using radio modems, leased-line modems or satellite uplinks

Product Design

The MicroLogix 1000 controller contains the power supply, processor, and all its I/O circuits

packaged in a single unit.

Four I/O sizes (10, 16, 25, and 32) cover many applications.

Various electrical configurations of digital I/O offer you a controller that meets your electrical requirements:

o 24V DC inputs and relay outputs with a 24V DC

power supply.o 24V DC inputs and 24V DC FET and relay outputs

with a 24V DC power supply.

Page 2: Some stuff  Regarding PLC Micrologix 1000 & 1100

o 24V DC inputs and relay outputs with a

120/240V AC power supply.o 24V AC inputs and relay outputs with a

120/240V AC power supply.o 120V AC inputs and relay outputs with a

120/240V AC power supply.o 120V AC inputs and triAC and relay outputs with

a 120/240V AC power supply. Isolated relay contact outputs (at least two per

controller). Allow outputs on the same unit to switch different control voltages.

The 25-I/O models include 4 analog inputs and an analog output in addition to the 12 digital inputs and the 8 digital (contact) outputs.

Communication

Point-to-Point—RS-232 communication port configurable for direct connection to your programming device.

DH-485—RS-232 communication port configurable for DH-485 communication through an AIC+ (1761-NET-AIC) converter. Lets you communicate with SLC 500 processors, other MicroLogix controllers, operator interfaces, or programming devices in a DH-485 network.

EtherNet/IP—RS-232 communication port configurable for EtherNet/IP communication through an EtherNet/IP-to-RS-232 interface (1761-NET-ENI). The 1761-NET-ENI supports program monitoring and upload/download, data collection from PCs or mainframes, and controller peer-to-peer communication. It can also send e-mail messages via SMTP (Simple Mail Transfer Protocol), and can display status and configuration information through a built-in Internet server.

DeviceNet—RS-232 communication port configurable for communication through a DeviceNet interface (1761-NET-DNI) lets the controller function as a slave node in a DeviceNet network or as a peer to other controllers also using the 1761-NET-DNI interface.

DF1, half-duplex—RS-232 communication port configurable for DF1 half-duplex slave protocol for connection to a modem in SCADA applications.

Page 7: Some stuff  Regarding PLC Micrologix 1000 & 1100

Specifications

General Specifications

24V DC Sensor Power 200 mA max. with 200 F capacitive load max. (for 1761-L10BWA, -L16NWA, -L16BWA, -L20BWA-5A, and -L32BWA only)

Power Cycles 50,000 minimum

Temperature, operating

Horizontal mounting 0…55 °C (32…131 °F)

Vertical mounting 0…40 °C (32…104 °F)

Temperature, nonoperating -40…85 °C (-40…185 °F)

Humidity 5…95% (without condensation)

Shock, operating 10 g peak acceleration (7.5g DIN rail mounted)  (11±1 ms duration), 3 times each direction, each axis

Shock, nonoperating 20 g peak acceleration (11±1 ms duration), 3 times each direction, each axis

Vibration 5 Hz to 2 kHz, 0.381 mm (0.015 in) peak-to-peak / 2.5 g panel mounted , 1hr per axis

Page 8: Some stuff  Regarding PLC Micrologix 1000 & 1100

Vibration, Non-Operating 5 Hz to 2 kHz, 0.762 mm (0.030 in) peak-to-peak / 5 g panel mounted, 1hr per axis

Terminal Screw Torque 0.9 N-m maximum (8.0 pound-inch)

Electrostatic Discharge IEC801-2 @ 8 KV

Radiated Susceptibility IEC801-3 @ 10V/m, 27…1000 MHz3V/m, 87…108 MHz, 174…230 MHz, and 470…790 MHz

Fast Transient IEC801-4 @ 2 KV Power Supply, 1 KV I/O

Isolation 1500V AC

Memory Type EEPROM

Memory Size 1K words (approximately 737 instruction words, 437 data-table words)

Timers/Counters, Max. 40 timers; 32 counters (fixed)

Program Scan Time/Kword, Typical

2 ms

I/O Scan Time, Typical 0.21 ms

Communication Port RS-232-C (Can be configured for communication through 1761-NET-AIC in a DH-485 network)

  

 Relays are derated an additional 2.5g on 32 I/O controllers. DIN rail mounted controller is 1g.

MicroLogix 1000 Controllers

Cat. No. I/O

Digital Inputs

AnalogInputs

Digital Outputs

Analog Outputs

Real Input Power

Apparent Input Power

Transformer Load

1761-L10BWA 10 6 inputs24V DC sink/source

0 4 contact outputs

0 13W @ 120V AC14W @ 240V AC

24 VA @ 120V AC32 VA @ 240V AC

33 VA @ 120V AC35 VA @ 240V AC

1761-L10BWB 10 6 inputs24V DC sink/source

0 4 contact outputs

0 5W @ 24V DC

— —

1761-L10BXB 10 6 inputs24V DC sink/source

0 2 contact outputs2 source

0 5W @ 24V DC

— —

Page 9: Some stuff  Regarding PLC Micrologix 1000 & 1100

24V DC outputs

1761-L16AWA 16 10 inputs120V AC

0 6 contact outputs

0 7W @ 120V AC8W @ 240V AC

15 VA @ 120V AC21 VA @ 240 AC

18 VA @ 120V AC20 VA @ 240V AC

1761-L32AWA 32 20 inputs120V AC

0 12 contact outputs

0 9.1W @ 120V AC10.6W @ 240V AC

19 VA @ 120V AC25 VA @ 240V AC

23 VA @ 120V AC27 VA @ 240V AC

1761-L16BWA 16 10 inputs24V DC sink/source

0 6 contact outputs

0 14W @ 120V AC15W @ 240V AC

26 VA @ 120V AC33 VA @ 240V AC

35 VA @ 120V AC38 VA @ 240V AC

1761-L16NWA 16 10 inputs24V DC sink/source or 24V AC

0 6 contact outputs

0 14W @ 120V AC15W @ 240V AC

26 VA @ 120V AC33 VA @ 240V AC

35 VA @ 120V AC38 VA @ 240V AC

1761-L32BWA 32 20 inputs24V DC sink/source

0 12 contact outputs

0 15W @ 120V AC16W @ 240V AC

29 VA @ 120V AC36 VA @ 240V AC

38 VA @ 120V AC40 VA @ 240V AC

1761-L32AAA 32 20 inputs120V AC

0 10 triAC outputs, 120/240V AC2 contact outputs

0 7W @ 120V AC9W @ 240V AC

16 VA @ 120V AC22 VA @ 240V AC

18 VA @ 120V AC23 VA @ 240V AC

1761-L16BWB 16 10 inputs24V DC sink/source

0 6 contact outputs

0 5W @ 24V DC

— —

1761-L16NWB 16 10 inputs24V DC

0 6 contact outputs

0 5W @ 24V DC

— —

Page 10: Some stuff  Regarding PLC Micrologix 1000 & 1100

sink/source or24V AC

1761-L32BWB 32 20 inputs24V DC sink/source

0 12 contact outputs

0 7W @ 24V DC

— —

1761-L16BBB 16 10 inputs24V DCsink/source

0 4 source 24V DC outputs 2 contact outputs

0 5W @ 24V DC

— —

1761-L32BBB 32 20 inputs24V DC sink/source

0 10 source 24V DC outputs2 contact outputs

0 7W @ 24V DC

— —

1761-L20AWA-5A

25 12 inputs120V AC

2 voltage (±10V) 2 current (0…20 mA)

8 contact outputs

1 voltage/current(0…10V, 4…20 mA)

12W @ 120V AC13W @ 240V AC

20 VA @ 120V AC27 VA @ 240V AC

30 VA @ 120V AC33 VA @ 240V AC

1761-L20BWA-5A

25 12 inputs24V DC sink/source

2 voltage (±10V) 2 current (0…20 mA)

8 contact outputs

1 voltage/current(0…10V, 4…20 mA)

18W @ 120V AC19W @ 240V AC

30 VA @ 120V AC38 VA @ 240V AC

45 VA @ 120V AC48 VA @ 240V AC

1761-L20BWB-5A

25 12 inputs24V DC sink/source

2 voltage (±10V) 2 current (0…20 mA)

8 contact outputs

1 voltage/current(0…10V, 4…20 mA)

7W @ 24V DC

— —

  

Analog Input Specifications

Voltage Range ±10.5V -1LSB

Current Range 0…20 mA -1LSB

Page 11: Some stuff  Regarding PLC Micrologix 1000 & 1100

Data Format Natural binary 16-bit signed integer

Voltage Input Impedance

210 kW

Current Input Impedance

160 kW

Resolution 16 bits 

Overall Accuracy 0…55 °C

±0.7% of full scale

  

 Also a function of the input filter selection.

Analog Output Specifications

Voltage Range 0…10V -1LSB

Current Range 4…20 mA -1LSB

Data Format Natural binary 16-bit signed integer

Step Response 2.5 ms @ 95%

Load Range 0…500

Current Output Coding (4…20 mA -1LSB, 0…10V -1LSB)

0…32,767

Resolution 15 bits

Overall Accuracy 0…55 °C ±1.0% of full scale

  

System Overview

Page 12: Some stuff  Regarding PLC Micrologix 1000 & 1100

The MicroLogix 1000 family provides

small, economical programmable

controllers. They are available in

configurations of 10 digital I/O (6

inputs and 4 outputs), 16 digital I/O

(10 inputs and 6 outputs), 25 I/O (12

digital inputs, 4 analog inputs, 8 digital

outputs, and 1 analog output), or 32

digital I/O (20 inputs and 12 outputs) in

multiple electrical configurations of digital I/O. The I/O options and electrical configurations

make them ideal for many applications.

Benefits

Compact design—Lets the MicroLogix 1000 controller thrive in limited panel space.

Choice of communication networks—An RS-232-C communication port is configurable for: DF1 protocol for direct connection to a programming device or operator interface; DH-485 networking through a 1761-NET-AIC converter; DeviceNet networking through a 1761-NET-DNI interface; EtherNet/IP networking through a 1761-NET-ENI interface; or for half-duplex slave protocol in SCADA applications.

Simple programming with your choice of programming device—You can program these controllers in familiar

ladder logic with MicroLogix 1000 A.I. Series Software®, PLC 500 A. I. Series Programming Software, RSLogix 500™ Windows Programming Software, or the MicroLogix Hand-Held Programmer (1761-HHP-B30). This symbolic programming language is based on relay ladder wiring diagrams that simplify the creation and troubleshooting of your control program.

Comprehensive instruction set—Over 65 instructions including simple bit, timer, and counter instructions, as well as instructions for powerful applications like sequencers, high-speed counter, and shift registers.

Page 13: Some stuff  Regarding PLC Micrologix 1000 & 1100

Fast—Execution time for a typical 500-instruction program is only 1.56 ms.

Choice of languages—Software and documentation are available in 5 languages. The hand-held programmer has 6 languages built in.

RSLogix 500 Software

The RSLogix family of ladder logic programming packages helps you maximize performance,

save project development time, and improve productivity. This family of products has been

developed to operate on Microsoft Windows operating systems. Supporting the Allen-Bradley

SLC 500 and MicroLogix families of processors, RSLogix 500 was the first PLC programming

software to offer unbeatable productivity with an industry-leading user interface. RSLogix 5

supports the Allen- Bradley PLC-5 family of programmable controllers. RSLogix 5000

provides support for the Logix5000 Highly Integrated Motion functionality. RSLogix offers

reliable communications, powerful functionality, and superior diagnostics.

RSLogix 500 Selection

Cat. No. Description

Page 14: Some stuff  Regarding PLC Micrologix 1000 & 1100

9324-RL0100ENE RSLogix 500 Starter Edition Programming Software for SLC 500 and MicroLogix controller families. (CD-ROM)

9324-RL0300ENE RSLogix 500 Standard Edition Programming Software for SLC 500 and MicroLogix controller families. (CD-ROM)

9324-RL0700NXENE

RSLogix 500 Professional Edition. CD-ROM also includes RSLogix Emulate 500, RSNetWorx for DeviceNet and RSNetWorx for ControlNet.

  

RSLogix Emulate 500 Software

Test and debug all of your ladder logic programs prior to commissioning and startup. RSLogix Emulate 5, RSLogix Emulate 500 and RSLogix Emulate 5000 are Microsoft Windows-based software packages that emulate one or more PLC-5, SLC 500 or Logix5000 processors, respectively. You determine which PLC-5, SLC 500, Logix5000 ladder programs you want to run, and RSLogix Emulate scans the ladder logic like an actual processor. In addition, RSLogix Emulate 5000 has built-in support for all RSLogix 5000 supported languages such as ladder logic, function block, sequential function chart and structured text.

1763 MicroLogix 1100 Controllers

With online editing and a built-in 10/100 Mbps EtherNet/IP port for peer-to-

peer messaging, the MicroLogix 1100 controller adds greater connectivity

and application coverage to the MicroLogix family of Allen-Bradley

controllers. This next generation controller's built-in LCD screen displays

controller status, I/O status, and simple operator messages; enables bit and

integer manipulation; offers digital trim pot functionality, and a means to

make operating mode changes (Prog / Remote / Run).

Page 15: Some stuff  Regarding PLC Micrologix 1000 & 1100

With 10 digital inputs, 2 analog inputs and 6 digital outputs, the MicroLogix

1100 can handle a wide variety of tasks. The MicroLogix 1100 controllers

also support expansion I/O. Up to four 1762 I/O modules (also used on the

MicroLogix 1200 and 1400) may be added to the embedded I/O, providing

application flexibility and support of up to 80 digital I/O.

Features

Built-in 10/100 Mbps EtherNet/IP port for peer-to-peer messaging — offers users high speed connectivity between controllers, with the ability to access, monitor and program from anywhere an Ethernet connection is available

Online editing functionality — modifications can be made to a program while it is running, making fine tuning of an operating control system possible, including PID loops. Not only does this reduce development time, but it aids in troubleshooting

Embedded Web server — allows a user to custom configure data from the controller to be displayed as a web page

Isolated RS-232/RS-485 combo port — provides a host of different point-to-point and network protocols

Embedded LCD screen — allows user to monitor data within the controller, optionally modify that data, and interact with the control program. Displays status of embedded digital I/O and controller functions, and acts as a pair of digital trim pots to allow a user to tweak and tune a program

Page 16: Some stuff  Regarding PLC Micrologix 1000 & 1100

Cat. No. Function Communication Interface

Communication RatesSupported (bit/s)

Current Load

1761-NET-AIC AIC+ Advanced Interface Converter

Lets you connect a MicroLogix controller (or other DH-485 protocol-capable RS232-C device) to the DH-485 network. This allows the controller to initiate or respond to communication with any other device (SLC 500 processors, other MicroLogix controllers, operator interfaces, or programming devices) on the network. With the ability to initiate communication, the MicroLogix controller can act as a single initiator (also referred to as a master or parent) on the network.

3 ports:• 2 RS-232• 1 DH-485

DH-485 protocol on all ports for networking

• 600• 1200• 2400• 4800• 9600• 14400• 19200

• 120 mA @ 24V DC• 200 mA inrush at power turn-on

1761-NET-DNI

DeviceNet RS-232-C Interface

Lets you connect a MicroLogix controller (or other DF1 Full-duplex addressable RS-232-C device) to the DeviceNet network. This allows the controller to function as a DeviceNet slave node to provide 16 words of input data and 16 words of output data that can be exchanged with the DeviceNet scanner. This also allows peer-to peer messaging between controllers. Lets you connect a PC-compatible computer to the DeviceNet network for peer-to-peer messaging, for programming, and for on-line monitoring.

Dual-shielded twisted pair (DeviceNet network)

DF1 Full-duplex protocol on RS-232 port

DeviceNet- selectable• 125k• 250k• 500k

RS-232-C selectable• 1200• 2400• 4800• 9600• 19200• 38400

• DeviceNet:   0…200 mA   (@ 11…25V)

1761-NET-ENI EtherNet/IP Lets you connect a 10/100 Base-T EtherNet/ RS-232-C 100 mA @

Page 17: Some stuff  Regarding PLC Micrologix 1000 & 1100

RS-232-C Interface

MicroLogix controller (or other DF1 full-duplex addressable RS-232-C device) to the EtherNet/IP network. This module supports:• program monitoring and upload/download.• data collection from PCs or mainframe computers.• controller peer-to-peer communication.• sending e-mail messages via SMTP.• access to configuration reference information via the Internet through built-in web-page server.

(RJ45) Port with embedded LEDs

DF1 Full-duplex protocol on RS-232 port

IP10/100 MHz

selectable• 2400• 4800• 9600• 19200• 38400

24V DC

1761-NET-ENIW

EtherNet/IP RS-232-C Interface

Lets you connect a MicroLogix controller (or other DF1 full-duplex addressable RS-232-C device) to the EtherNet/IP network. This module supports:• program monitoring and upload/download.• data collection from PCs or mainframe computers.• controller peer-to-peer communication.• sending e-mail messages via SMTP.• access to configuration reference information via the Internet, and offers built-in user-configurable web-page server with read/write capability.

10/100 Base-T (RJ45) Port with embedded LEDs

DF1 Full-duplex protocol on RS-232 port

EtherNet/IP10/100 MHz

RS-232-C selectable• 2400• 4800• 9600• 19200• 38400

100 mA @ 24V DC

  

Page 18: Some stuff  Regarding PLC Micrologix 1000 & 1100

HAND-HELD PROGRAMMER

Overview

The Hand-Held Programmer (1761-HHP-B30) lets you create

and modify programs for your MicroLogix Controller, and

monitor programs through features such as textual fault

messages, trace, and multi-point monitoring.

Benefits

Optional EEPROM memory modules—Offer you two convenient and safe ways to store or transfer eight programs (maximum of 64K bytes) between MicroLogix 1000 Programmable Controllers. The memory module is located in the back of the HHP. The 1761-HHMK08 memory module has 8K bytes. The 1761-HHMK64 memory module has 64K bytes.

Trace function—You can quickly find faulty input elements that prevent an output from turning on or off, which saves valuable troubleshooting time.

Multi-point monitor—Lets you monitor your most crucial bit addresses at the same time. All 16 addresses are stored with the controller.

Simple user interface—Reduces your keystrokes when entering and monitoring programs.

Small size—Makes the Hand Held Programmer unit easy for you to carry around and store.

Global programmer—You can program in English, French, German, Italian, Spanish, and Japanese through a six language multilingual display.

Page 19: Some stuff  Regarding PLC Micrologix 1000 & 1100

Textual fault messages—Gives fault code and messages in any of six languages making troubleshooting easier to perform.

Graphic display—Lets you program using the familiar basic ladder logic programming symbols.

Rung-based navigation. Permits easy movement through your program.

Specifications

Power Supply Loading 83 mA @ 24V DC (1.99W)

Temperature, operating 0…50 °C (32…122 °F)

Temperature, nonoperating

-20…60°C (-4…140 °F)

Humidity 5…95% (without condensation)

Display Type 2 line x 16 character (LCD)

Keypad 30 Rubber/carbon-based keys

Weight 0.3 kg (0.6 lb)

  

Dimensions


Recommended