SOTECH OPTIMA CLIP ON COPINGSSecret Fix Coping SystemComplete Secret Fixed | Fully Independently CWCT Tested and Certified | Extremely Robust
S O T E C H O P T I M A X P C
Only the top cutout of eachpanel fully engages the carrierhook.
Panel security screw.
Datum
Top of slot
5mm
5mm
Lower hooks on same panelare spaced to leave a 5mmexpansion gap.
For s
lots
/hoo
ks c
trs s
ee n
otes
bel
owD
imD
im
Fac
e H
eigh
t
Top of slot
Face Height 951mm+ 100mm down from top of panel face150mm up from bottom of panel faceAdditionally equally spaced intermediate holes max 700cts
Face Height 401>950 100mm down from top of panel face150mm up from bottom of panel face
Face Height 251>400 50mm down from top of panel face100mm up from bototm of panel face
Only the top hole of each panel makes contact with a support hook, all other hooksare 5mm lower to allow for expansion.
Typical Slot Setout Info.
Hook Centres.3mm Solid Aluminium - 400mm ctrs.
(ACM is shown in the details above which also apply to 3mm solid Aluminium.)
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHook Arrangement
FC-01 08.04.16
1:4 A
Sotech Optima XPC | Solid Aluminium System Details
Contents
3. Horizontal Panel Joints......................................................4. Vertical Panel Joints..........................................................5. Vertical Window Interface Detail........................................6. Window Jamb Detail..........................................................7. Horizontal Panels On Top Hats Fixed To SIPs...................8. Corner Detail - Vertical Rails..............................................9. Corner Detail - Horizontal Rails..........................................10. Movement Joint Detail........................................................
2
(XP-EP01)(XP-EP02)(XP-EP03)(XP-EP04)(XP-EP05)(XP-EP06)(XP-EP07)(XP-EP08)
Sotech Optima XPC | Solid Aluminium System Details
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
1
12
14
15
13
16
Cladding Zone
To Suit U Value
Facade Substrate & Weather Line
SFS to suit loads
Bkt
Mod
ule
Sub
ject
To C
alcs
ClosedJoint
OpenJoint
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
2
456
7
Tek Fixing - type to suit substrate material. By Others.
8 9
10
11
10
3
2
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankHorizontal Panel Joints
XP-EP01 08.04.16
1:3 A
2 3
(XP-EP01)(XP-EP02)(XP-EP03)(XP-EP04)(XP-EP05)(XP-EP06)(XP-EP07)(XP-EP08)
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Panel ModulePanel Module
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
8
16
1
121415 13
2
4 5 6
7
8 9
10
11
3
16
Optional Coloured Pressing.16
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankVertical Panel Joints
XP-EP02 08.04.16
1:3 A
4
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
1
456
8 9
Indicative Window System
16
Cladding Zone
To Suit U Value
Facade Substrate & Weather Line
SFS to suit loads
1
12
14
15
13
11
16
Aluminium Pressing.16
17
EPDM or Similar. By Others.17
7
16
17
2
3
10
5
8
Sika Structural Bond. By Others.18
18
18
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankVertical Window Interface Detail
XP-EP03 08.04.16
1:3 A
54
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
16
1
121415 13
4 5 6
89
Optional Coloured Pressing. 16
Indicative Window System
3
17
Aluminium Pressing. By Others.17
10 11 7
18
EPDM or Similar. By Others.18
2
5
8
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankWindow Jamb Detail
XP-EP04 08.04.16
1:3 A
6
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SIPS Insulated Panel. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
Optional Coloured Pressing.16Aluminium Pressing.17EPDM or Similar. By Others.18
1 12
15
13
16
Cladding Zone Facade Substrate & Weather Line
SIPS Panel
OpenJoint
2
89
16
Cladding Zone
102
ClosedJoint
Horizontal Panels onHorizontal Top Hats
Horizontal Panels onVertical Top Hats
10
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankHorizontal Panels On Top Hats Fixed To SIPs
XP-EP05 08.04.16
1:3 A
76
To Suit U ValueSFS to suit loads
Cladding Zone
Top Hat
Facade Substrate & Weather Line
Panel ModulePanel Module
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
1
121415 13
2
456
7
8 9
10
11
3
Optional Coloured Pressing.16
Pan
el M
odul
eP
anel
Mod
ule
Routed Panel ToForm Corner
16
8 Typical
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankCorner Detail - Vertical Rails
XP-EP06 08.04.16
1:3 A
8
To Suit U ValueSFS to suit loads
Cladding Zone
Top Hat
Facade Substrate & Weather Line
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
1
121415 13
2
4 5 6
7
8 9
10
11
3
Optional Coloured Pressing. 16
Routed Panel ToForm CornerPanel Module
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankCorner Detail - Horizontal Rails
XP-EP07 08.04.16
1:3 A
8 9
12345678
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13
Internal Finish. By Others.14 Insulation - If required. By Others.15
Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Fixing - type to suit substrate material. By Others.Isolator.
Extruded Aluminium "T".
Tek Fixing - type to suit substrate material. By Others.
Optional Coloured Pressing.16
8
5
To Suit Movement
Loop in breathermembrane
Loop in VCLmembrane
General annotationas per Drg XP-EP02
Pressing to suitreq'd detail.
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima X PlankMovement Joint Detail
XP-EP08 08.04.16
1:3 A
10