+ All Categories
Home > Documents > SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or...

SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or...

Date post: 06-Mar-2021
Category:
Upload: others
View: 9 times
Download: 0 times
Share this document with a friend
10
SOTECH OPTIMA CLIP ON COPINGS Secret Fix Coping System Complete Secret Fixed | Fully Independently CWCT Tested and Certified | Extremely Robust SOTECH OPTIMA XPC
Transcript
Page 1: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

SOTECH OPTIMA CLIP ON COPINGSSecret Fix Coping SystemComplete Secret Fixed | Fully Independently CWCT Tested and Certified | Extremely Robust

S O T E C H O P T I M A X P C

Page 2: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

Only the top cutout of eachpanel fully engages the carrierhook.

Panel security screw.

Datum

Top of slot

5mm

5mm

Lower hooks on same panelare spaced to leave a 5mmexpansion gap.

For s

lots

/hoo

ks c

trs s

ee n

otes

bel

owD

imD

im

Fac

e H

eigh

t

Top of slot

Face Height 951mm+ 100mm down from top of panel face150mm up from bottom of panel faceAdditionally equally spaced intermediate holes max 700cts

Face Height 401>950 100mm down from top of panel face150mm up from bottom of panel face

Face Height 251>400 50mm down from top of panel face100mm up from bototm of panel face

Only the top hole of each panel makes contact with a support hook, all other hooksare 5mm lower to allow for expansion.

Typical Slot Setout Info.

Hook Centres.3mm Solid Aluminium - 400mm ctrs.

(ACM is shown in the details above which also apply to 3mm solid Aluminium.)

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima FCHook Arrangement

FC-01 08.04.16

1:4 A

Sotech Optima XPC | Solid Aluminium System Details

Contents

3. Horizontal Panel Joints......................................................4. Vertical Panel Joints..........................................................5. Vertical Window Interface Detail........................................6. Window Jamb Detail..........................................................7. Horizontal Panels On Top Hats Fixed To SIPs...................8. Corner Detail - Vertical Rails..............................................9. Corner Detail - Horizontal Rails..........................................10. Movement Joint Detail........................................................

2

(XP-EP01)(XP-EP02)(XP-EP03)(XP-EP04)(XP-EP05)(XP-EP06)(XP-EP07)(XP-EP08)

Page 3: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

Sotech Optima XPC | Solid Aluminium System Details

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

1

12

14

15

13

16

Cladding Zone

To Suit U Value

Facade Substrate & Weather Line

SFS to suit loads

Bkt

Mod

ule

Sub

ject

To C

alcs

ClosedJoint

OpenJoint

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

2

456

7

Tek Fixing - type to suit substrate material. By Others.

8 9

10

11

10

3

2

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankHorizontal Panel Joints

XP-EP01 08.04.16

1:3 A

2 3

(XP-EP01)(XP-EP02)(XP-EP03)(XP-EP04)(XP-EP05)(XP-EP06)(XP-EP07)(XP-EP08)

Page 4: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

To S

uit U

Val

ueS

FS to

sui

t loa

ds

Cla

ddin

g Zo

ne

Top

Hat

Faca

de S

ubst

rate

& W

eath

er L

ine

Panel ModulePanel Module

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

8

16

1

121415 13

2

4 5 6

7

8 9

10

11

3

16

Optional Coloured Pressing.16

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankVertical Panel Joints

XP-EP02 08.04.16

1:3 A

4

Page 5: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

1

456

8 9

Indicative Window System

16

Cladding Zone

To Suit U Value

Facade Substrate & Weather Line

SFS to suit loads

1

12

14

15

13

11

16

Aluminium Pressing.16

17

EPDM or Similar. By Others.17

7

16

17

2

3

10

5

8

Sika Structural Bond. By Others.18

18

18

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankVertical Window Interface Detail

XP-EP03 08.04.16

1:3 A

54

Page 6: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

To S

uit U

Val

ueS

FS to

sui

t loa

ds

Cla

ddin

g Zo

ne

Top

Hat

Faca

de S

ubst

rate

& W

eath

er L

ine

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

16

1

121415 13

4 5 6

89

Optional Coloured Pressing. 16

Indicative Window System

3

17

Aluminium Pressing. By Others.17

10 11 7

18

EPDM or Similar. By Others.18

2

5

8

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankWindow Jamb Detail

XP-EP04 08.04.16

1:3 A

6

Page 7: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SIPS Insulated Panel. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

Optional Coloured Pressing.16Aluminium Pressing.17EPDM or Similar. By Others.18

1 12

15

13

16

Cladding Zone Facade Substrate & Weather Line

SIPS Panel

OpenJoint

2

89

16

Cladding Zone

102

ClosedJoint

Horizontal Panels onHorizontal Top Hats

Horizontal Panels onVertical Top Hats

10

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankHorizontal Panels On Top Hats Fixed To SIPs

XP-EP05 08.04.16

1:3 A

76

Page 8: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

To Suit U ValueSFS to suit loads

Cladding Zone

Top Hat

Facade Substrate & Weather Line

Panel ModulePanel Module

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

1

121415 13

2

456

7

8 9

10

11

3

Optional Coloured Pressing.16

Pan

el M

odul

eP

anel

Mod

ule

Routed Panel ToForm Corner

16

8 Typical

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankCorner Detail - Vertical Rails

XP-EP06 08.04.16

1:3 A

8

Page 9: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

To Suit U ValueSFS to suit loads

Cladding Zone

Top Hat

Facade Substrate & Weather Line

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

1

121415 13

2

4 5 6

7

8 9

10

11

3

Optional Coloured Pressing. 16

Routed Panel ToForm CornerPanel Module

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankCorner Detail - Horizontal Rails

XP-EP07 08.04.16

1:3 A

8 9

Page 10: SOTECH OPTIMA CLIP ON COPINGS SOTECH OPTIMA XPC...13 11 16 16 Aluminium Pressing. 17 17 EPDM or Similar. By Others. 7 16 17 2 3 10 5 8 18 Sika Structural Bond. By Others. 18 18 @A4

12345678

Insulation - thickness & type to suit specification. By Others.

Top Hat - material to suit span. By Others.9Breathable Membrane. By Others.10Cemetitious Board (or simiar), thickness to suit specification. By Others.11SFS Substrate - profile size & centres to suit loadings. By Others.12V.C.L. - if required. By Others.13

Internal Finish. By Others.14 Insulation - If required. By Others.15

Optima X-Plank Extruded Panel - finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).

Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.

Fixing - type to suit substrate material. By Others.Isolator.

Extruded Aluminium "T".

Tek Fixing - type to suit substrate material. By Others.

Optional Coloured Pressing.16

8

5

To Suit Movement

Loop in breathermembrane

Loop in VCLmembrane

General annotationas per Drg XP-EP02

Pressing to suitreq'd detail.

@A4

Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU

Title:

Drg No:

Rev:Scale: Checked By:

Date:Drawn By:

DD

Sotech

Tel: 0191 587 2287Fax: 0191 518 0703

www.sotech-optima.co.uk

Optima X PlankMovement Joint Detail

XP-EP08 08.04.16

1:3 A

10


Recommended