+ All Categories
Home > Documents > Sound Transmission Class for Masonry Walls. 2 Standard Method for Determining the Sound Transmission...

Sound Transmission Class for Masonry Walls. 2 Standard Method for Determining the Sound Transmission...

Date post: 17-Dec-2015
Category:
Upload: ruth-oconnor
View: 298 times
Download: 6 times
Share this document with a friend
Popular Tags:
25
Sound Transmission Class for Masonry Walls
Transcript

Sound Transmission Class for Masonry

Walls

2

Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls(TMS 0302)

3

TMS 0302

1.0 Scope

2.0 Referenced Standards

3.0 Notations

4.0 Definitions

5.0 Materials

6.0 Construction

7.0 Quality Assurance

8.0 Sound Transmission Class (STC) Rating

4

TMS 03021.0 SCOPE

• Minimum requirements for STC

• Field or laboratory standard test methods, or

• Calculation procedure

5

TMS 03024.0 DEFINITIONS

Sound Transmission Class, STC• Single number rating – ASTM E413

6

Shall comply with the following ASTM standards:

• C34, C55, C56, C62, C73, C90, C126, C129, C212, C216, C652, or C744

TMS 03025.1 MASONRY UNITS

7

Shall comply with ASTM C270

TMS 03025.2 MORTAR

8

Shall comply with ASTM C476

TMS 03025.3 GROUT

9

Shall conform to the requirements:

•General building code

• Standard

TMS 03026.0 CONSTRUCTION

10

Hollow units – face shell mortared head and bed joints

Solid units – full mortared head and bed joints

TMS 0302 6.1 PLACING MORTAR AND

MASONRY UNITS

11

Completely seal through-wall openings.

Prior to sealing fill gaps with:• Foam

•Cellulose fiber

•Glass fiber

•Ceramic fiber

•Mineral wool

TMS 03026.2.1 SEALING OPENINGS AND

JOINTS

12

Completely seal partial-wall penetration openings and inserts.

TMS 03026.2.2 SEALING OPENINGS AND

JOINTS

13

Seal the following w/elastomeric joint sealants (ASTM C920):•Control joints

• Expansion joints

• Top of walls and roof

•Roof assemblies

TMS 03026.2.3 SEALING OPENINGS AND

JOINTS

14

Fill joint space behind sealant with:•Mortar

•Grout

• Foam

•Cellulose fiber

•Glass fiber

•Mineral wool

TMS 03026.2.3 SEALING OPENINGS AND

JOINTS

15

TMS 0302 (Commentary)FIG. 6.2.1 ACOUSTICAL LEAKS

16

TMS 0302 (Commentary)FIG. 6.2.2 SEALING AROUND

PENETRATIONS AND FIXTURES

17

Determine in accordance with: 8.1 Laboratory testing – ASTM E 90

8.2 Field testing – ASTM E413

8.3 Calculation

TMS 03028.0 SOUND TRANSMISSION CLASS

RATING

18

For walls greater than 3 inches

STC = 0.18W + 40 (Eq.1)

W = Wall Weight, psf

TMS 03028.3 CALCULATION

19

TMS 0302 (Commentary)

20

TMS 0302 (Commentary)FIG 8.3-1 WALL WEIGHT VS. STC

21

TMS 0302TABLE 8.3-1

22

TMS 0302 (Commentary)TABLE 8.3-2 – CALCULATED STC RATINGS

FOR CONCRETE MASONRY WALLS

23

EXAMPLE

Given:

W = wall weight = 41 psf

STC = 0.18W + 40

STC = 0.18(41) + 40

STC = 47.4

24

NCMA TEK 13-2

25

NCMA TEK 13-2


Recommended