+ All Categories

sp10osb

Date post: 26-Jun-2015
Category:
Upload: sp10osb
View: 174 times
Download: 0 times
Share this document with a friend
Popular Tags:
93
VISUAL DICTIONARY BSCI 2300 4/26/10 Mwf 11-11:50
Transcript
Page 1: sp10osb

VISUAL DICTIONARYBSCI 2300

4/26/10Mwf 11-11:50

Page 2: sp10osb

Air Barrier Paper – an external membrane applied to the sheathing below the veneer which serves as a weather barrier and helps to prevent air infiltration into the home.

Page 3: sp10osb

Attic Ventilation

Attic Ventilation – Serves to allow water vapor to escape and to allow the hot attic air to escape by providing an intake at the eaves through the soffit vents which allows the warmer air to escape through the roof vents.

Page 4: sp10osb

Gable Vent – Allows hotter attic air to escape and prevents buildup of heat conducted through the roof of the structure

Page 5: sp10osb

Ridge Vent – Allows hot attic air to escape through a gap in the ridge decking

Page 6: sp10osb

Roof Turbine – allows the air to escape by drawing it out through the roof like a fan

Page 7: sp10osb

Soffit Vent – Allows air into the attic so that the warmer air can be pushed out through the vents placed higher on the roof

Page 8: sp10osb

Backhoe – Heavy machinery used for excavation in smaller site clearing projects like tree removal and used to dig footings and some basement excavation. 18 inch bucket

Page 9: sp10osb

Batter Boards – A temporary frame built just outside the corners of a foundation excavation. They are used to make sure the structure is square and to also carry the lines of a footing from corner to corner.

Page 10: sp10osb

Radius Arch

Page 11: sp10osb

Segmented Arch

Page 12: sp10osb

Arch w / Keystone

Page 13: sp10osb

Centering

Page 14: sp10osb

Running Bond – Continuous row of stretchersRunning Bond – Continuous row of stretchers

Page 15: sp10osb

Flemish bond - one stretcher followed by a header and then repeated

Page 16: sp10osb

Soldier

Page 17: sp10osb

Sailor

Page 18: sp10osb

Stretcher Rowlock

Page 19: sp10osb

Header

Page 20: sp10osb

Rowlock

Page 21: sp10osb

Queen Size 3” w x 2 ¾” h x 7 5/8” l

Page 22: sp10osb

Modular 3”w x 2.75”h x 7 5/8L

Page 23: sp10osb

Bulldozer – heavy machinery used during site prep. It is used to level the dirt off by grading with the front blade and pushing dirt around small areas of the construction site.

Page 24: sp10osb

Brick Clad & Stone Clad – random ashlar

Page 25: sp10osb

Wood Board Clad

Page 26: sp10osb

EIFS

Page 27: sp10osb

Wood Shake – small shingle split from a block of wood, which gives a rough texture and uneven depthsWood Shingle – sawn shingle, typically more smooth and uniform; also larger in size

Page 28: sp10osb

Windows : minimum opening of 5.7 square feet (5.0 if sill is less than 44” AFF)Opening width 20” minimum & opening height 24” minimum.

Actual Measurements – 28” h x 33” w x 43.5” AFF.

Total Area : 6.41 sq. ft.

The window meets the code requirements

Page 29: sp10osb

Code requirements – Riser Height 7 ¾” maximum Tread Depth 10” nosing to nosingActual measurements – Riser Height of 7 5/8 tread depth 11 5/8” (less 1 ½ “ overhang) gives 10 1/8”. Therefore, the stair is in compliance with the code.

Page 30: sp10osb

Control Joint – a designed cut in concrete to weaken the slab at that point in an attempt to prevent cracking elsewhere in the concrete

Page 31: sp10osb

Isolation joints - separate concrete from objects or structures, and allow independent movement without any connection that could cause damage to either object. This joint separates the wall from the slab.

Page 32: sp10osb

CMU – a block of hardened concrete designed to be laid up like regular masonry brick. The hollow cores allow for the block walls to be filled with concrete for additional strength. CMU is more economical for foundation walls than cast concrete, and when laid by a proper mason, one course of block is equal to 3 courses of standard brick w/ a 3/8” mortar joint. A typical block is 8” x 8” x 16” with a 3/8” mortar joint.

Page 33: sp10osb

Two different size blocks one is a 8” x 8” x16” the other is a 8” x 12” x 16”

Page 34: sp10osb

Decorative CMU

Split Block

Page 35: sp10osb

Ribbed Block

Page 36: sp10osb

Flush Door

Page 37: sp10osb

Bottom Rail

Doors

Top Rail

Style

Panel

Lock Rail

Page 38: sp10osb

Transom – A small window directly over a door

Page 39: sp10osb

Sidelight – A tall, narrow widow running alongside a door

Page 40: sp10osb

Underground Transformer Box – Steps down the electricity from a few thousand volts to the 110v / 220v service needed for the home

Page 41: sp10osb

Service Head – Brings the electricity into the meter and isolates that particular residence through an in-line fuse which prevents the house wiring from interfering with other structures on the grid

Meter – Measures how much electricity is being used

Page 42: sp10osb

Service Panel – the point where the electricity enters the home. The panel distributes the electricity throughout the home through individual circuits.

Page 43: sp10osb

Duplex Receptacle – where the power is accessed in the home

Page 44: sp10osb

Framing Elements

# 1 Anchor bolt

#2 sill plate

Page 45: sp10osb

Framing Elements

# 3 Floor Joist

#4 Sub Floor

Page 46: sp10osb

Framing Elements

# 5sole plate

#6 Stud

#7 Top Plate

Page 47: sp10osb

Framing Elements

#8 Stringer

Page 48: sp10osb

#9 Ceiling Joist

#10 Rafter

#11 Roof decking

#12 Sheathing

Page 49: sp10osb

Front End Loader – used for transporting piles of dirt or other material across a jobsite. The hydraulic arms on the bucket allows the ability to place material at a raised elevation – useful for loading dump trucks and backfilling retaining walls. Unlike a bulldozer, a loader has the ability to scoop dirt out of the ground and move it to another location rather than spreading it around an area

Page 50: sp10osb

Gypsum Board – An interior finish board made from a gypsum core sandwiched between two paper faces.

Page 51: sp10osb

Compressor – compresses the refrigerant gas which gives off heat, thus cooling the air as it blows across the cooler coils at the air handler

One main disadvantage of the heat pump system is that it is noisy. One must take into account where to place the outside compressors to avoid noise intrusion into the home.

Page 52: sp10osb

Air Handler – Forces the air through the system with the use of a blower fan. Also, cooler air is blown across a heating element inside the air handler to warm it up before distributing it through the ductwork

One advantage of heat pump systems is that it is the most efficient way to heat and cool a home

Page 53: sp10osb

Batt Insulation

Insulation is used to create the thermal envelope for the house to reduce air infiltration/ heat loss in the home

Page 54: sp10osb

Loose Fill

Insulation

Page 55: sp10osb

Foamed Insulation

Insulation

Page 56: sp10osb

Rigid Board Insulation

Insulation

Page 57: sp10osb

Steel Lintel – A beam that carries the load of the wall across a door or window

Page 58: sp10osb

Flush Joint – This house used a 3/8” troweled joint with type ‘N’ mortar

Page 59: sp10osb

Rake joint – this house has a 3/8” tooled mortar joint with type N mortar

Page 60: sp10osb

OSB – a nonveneered panel made up of long strands of wood particles which are compressed and glued together in several layers, with each layer oriented opposite the direction of the previous layer for strength

Page 61: sp10osb

Lavatory – uses 1 1/2” drain pipe

Page 62: sp10osb

Water Closet – uses 3” pipe to drain

Page 63: sp10osb

Vent Through Roof – allows air to enter the plumbing system which lets the water drain from the pipes

Page 64: sp10osb

Drop in kitchen sink

Page 65: sp10osb

Plywood – manufactured by gluing thin veneers of wood together, rotating each layer 90 degrees so that the grain in the wood does not run the same in each layer. This provides greater strength and equalizes moisture movementVeneer – a thin layer or facing

Plywood

Page 66: sp10osb

Radiant BarrierA reflective foil placed adjacent to an airspace in a roof or wall

assemblies as a deterrent to the passage of infrared energy.

Page 67: sp10osb

#4 rebar (1/2” thickness) used here to tie the center of this wall to the footing in an attempt to curb differential settlement and add strength to the wall. Deformations are in the rebar to help the concrete hold on to the rebar.

Rebar

Page 68: sp10osb

Gutter – a channel which collects rainwater at the eave of a roofDownspout – A vertical pipe for conducting the rainwater from the gutter to a lower level discharge point

Page 69: sp10osb

Splashblock – a precast concrete block used to dissipate the water at the downspout’s discharge point

Page 70: sp10osb

Underlayment – A thin layer of waterproof material laid between the roof deck and roofing. It allows to get the house in the dry so progress will not be held up due to inclement weather and protects the building before the roofing is applied

Page 71: sp10osb

Clay Tile Roof

Page 72: sp10osb

Shingle – A water resistant material nailed in an overlapping pattern with other like materials to make the roof watertight.

Slate Shingle Roof

Page 73: sp10osb

Metal Panel RoofCopper

Page 74: sp10osb

Gable Roof

Page 75: sp10osb

Gambrel Roof

Page 76: sp10osb

Hip Roof

Page 77: sp10osb

Mansard Roof

Page 78: sp10osb

Eave – the level, low edge of the roof

Page 79: sp10osb

Ridge – the level intersection of roof planesValley – the sloping intersection of roof planes when water runs to it

Page 80: sp10osb

Rake – The Sloping edge of a steep roof

Page 81: sp10osb

Fascia – the exposed vertical face of the eave

Soffit – the undersurface of a roof overhang, installed to enclose the rafter tails

Page 82: sp10osb

No Fascia – house with exposed rafter tails

Page 83: sp10osb

Stone

Random Rubble Pattern

Page 84: sp10osb

Coursed Rubble Pattern

Stone

Page 85: sp10osb

Random Ashlar Pattern

Stone

Page 86: sp10osb

Coursed ashlar pattern

Page 87: sp10osb

Vapor Retarder – put in place to reduce the passage of air and water vapor through the building assembly to prevent condensation. It is usually placed to the inside of the building.

Page 88: sp10osb

Waterproofing – installed to prevent the passage of water through the CMU into a basement or crawlspace. This is an example of liquid applied

Page 89: sp10osb

Weep hole – a small opening in the brick veneer to allow accumulated water from the building to escape

Page 90: sp10osb

WWF – 6” x 6” grid

Page 91: sp10osb

Double Hung WindowVinyl Clad

Both the top & bottom sash open

Page 92: sp10osb

Casement WindowVinyl Clad

The window cranks out from a side hinge

Page 93: sp10osb

Single HungVinyl

Only the bottom sash is operable