www.sikora.net SPARK 2000 BS SPARK 2000 BS High-voltage spark tester for cable production lines
Transcript
Page 1: SPARK 2000 BS EN -   · PDF file  SPARK 2000 BS SPARK 2000 BS High-voltage spark tester for cable production lines

www.sikora.net

SPARK 2000 BS

SPARK 2000 BSHigh-voltage spark testerfor cable production lines

Page 2: SPARK 2000 BS EN -   · PDF file  SPARK 2000 BS SPARK 2000 BS High-voltage spark tester for cable production lines

SIKORA AGHeadquartersBruchweide 228307 BremenGermanyPhone+49 421 48900 [email protected]

SIKORA ASIA CORPFuzhou, P.R. [email protected]

SIKORA BRASILSão Paulo, [email protected]

SIKORA INDIANew Delhi, [email protected]

SIKORA ITALIAVicenza, [email protected]

SIKORA KOREASeoul, [email protected]

SIKORA RUSSIAMoscow, [email protected]

SIKORA UKRAINEVinnitsa, [email protected]

SIKORA INTERNATIONAL CORPPeachtree City, [email protected]

www.sikora.net

GD

/HB/

KB/8

00/0

4/08

Typical Features

• Controlled output voltage• Bead chain electrode for reliable, non destructive wire/

cable testing• RS 485/Profibus DP/analog interfaces• RS 232 diagnosis interfaces• Highest safety level• Fulfills important test standards (UL, VDE, CENELEC, BS,

AS, CS etc.) and safety regulations (DIN/VDE 0800, IEC479-1)

High-voltage spark tester

SPARK 2000 BSWith the SPARK 2000 BS SIKORA fulfils essential require-ments that are demanded for a Spark Tester today. Equipped with a robust bead chain electrode the SPARK 2000 BS pre-cisely detects defects in the insulation during the production. This innovative spark tester was specially developed for lar-ger cable diameters up to 200 mm and is mostly used for the high-voltage cable production. The test voltage ranges from 1.6 to 25 kV.

The solid electrode and the electronic box of the SPARK 2000 BS form one integral unit. Optionally, the display and control device REMOTE 2000 can be fully integrated. The spark tester conforms to approved test standards (UL, VDE, CENELEC, BS, AS, CS) and safety regulations (as demanded by DIN/VDE 0800, IEC 479-1).

ISO 9001

QUALITY

SIKORA

Certified according toDIN EN ISO 9001:2000

SPARK 2000 BS in the stand-alone version

TECHNICAL DATA SPARK 2000 BS

Product diameter

Test voltage range

Test frequency

Max. line speed

Contact outputs

Power supply

1 to 200 mm

1.6-25 kV (Optionally 30, 35 kV)

50 Hz, Sinus

380 m/min

Electrically isolated

100-230 V, ± 10 %

Technical data is subject to change