Pacific Gas and Electric Company Lawrence F. Womack Diablo Canyon Power Plant Vice President P.O. Box 56 Nuclear Technical Services Avila Beach, CA 93424 December 15, 1999 805.545.6000 PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Special Report 99-05, Supplement 1. Emergency Response Data System (ERDS) Data Point Library Up-grade Dear Commissioners and Staff: As requested by NRC's letter requesting supplemental data dated September 20, 1999, and clarification from ERDS Project Officer, Mr. John Jolicoeur, per teleconference on October 7, 1999, this supplement to Special Report 99-05 is submitted to provide additional information regarding data points provided via PG&E Letter DCL-99-086, dated June 18, 1999. The ERDS system was installed as documented in PG&E Letter No. DCL-91-261, "Emergency Response Data System Implementation Plan," dated October 25, 1991. The Safety Parameter Display System (SPDS) system was installed in response to NUREG-0737, Action Plan Item I.D.2, and NUREG-0696 (circa 1980). PG&E upgraded the SPDS computer system during 1996 (reference DCL-98-136, "10 CFR 50.59 Report of Facility Changes, Tests, and Experiments for the Report Period May 24, 1996 March 28, 1998"). The upgraded SPDS is Y2K compliant and has been further enhanced to provide the ERDS function. PG&E has enhanced the data points requested in NUREG-1394, Revision 1, dated May 1991, with clarification provided by the ERDS Project Officer, as "ERDS Data Point Library, Revision 2," enclosed. Sincerely, Lawrence F. Womack Enclosure cc: Steven D. Bloom John Jolicoeur, ERDS Project Officer (w/enclosure) 0 ilk Ellis W. Merschoff David L. Proulx NRC Ooeration Center VS)I:> J~ctc
Transcript
Page 1: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Pacific Gas and Electric Company

Lawrence F. Womack Diablo Canyon Power Plant Vice President P.O. Box 56 Nuclear Technical Services Avila Beach, CA 93424

December 15, 1999 805.545.6000

PG&E Letter DCL-99-161

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Special Report 99-05, Supplement 1. Emergency Response Data System (ERDS) Data Point Library Up-grade

Dear Commissioners and Staff:

As requested by NRC's letter requesting supplemental data dated September 20, 1999, and clarification from ERDS Project Officer, Mr. John Jolicoeur, per teleconference on October 7, 1999, this supplement to Special Report 99-05 is submitted to provide additional information regarding data points provided via PG&E Letter DCL-99-086, dated June 18, 1999.

The ERDS system was installed as documented in PG&E Letter No. DCL-91-261, "Emergency Response Data System Implementation Plan," dated October 25, 1991. The Safety Parameter Display System (SPDS) system was installed in response to NUREG-0737, Action Plan Item I.D.2, and NUREG-0696 (circa 1980). PG&E upgraded the SPDS computer system during 1996 (reference DCL-98-136, "10 CFR 50.59 Report of Facility Changes, Tests, and Experiments for the Report Period May 24, 1996 March 28, 1998"). The upgraded SPDS is Y2K compliant and has been further enhanced to provide the ERDS function. PG&E has enhanced the data points requested in NUREG-1394, Revision 1, dated May 1991, with clarification provided by the ERDS Project Officer, as "ERDS Data Point Library, Revision 2," enclosed.

Sincerely,

Lawrence F. Womack

Enclosure

cc: Steven D. Bloom John Jolicoeur, ERDS Project Officer (w/enclosure) 0 ilk Ellis W. Merschoff David L. Proulx NRC Ooeration Center

VS)I:> J~ctc

Page 2: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

AX FD FL 1

FTSOA

SG 1-1 AFW FLOW FT-S0

Stm Gen 1 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

SENS

1

POLY

Down

None

10

stream of Level Control Valves

N/A

N/A

Low

None

Wet

N/A

Page 1 of 52

Ai

ERDS Data Point Library (Rev 2)

Page 3: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

AX FD FL 2

FT77A

SG 1-2 AFW FLOW FT-77

Stm Gen 2 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

unique system Desc:

SENS

1

POLY

Down

None

N/A

N/A

LOW

None

Wet

N/A

10

stream of Level Control Valves

Page 2 of 52

ERDS Data Point Ubrary (Rev 2)

Page 4: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Di gi tal :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

AX FD FL 3

FT78A

SG 1-3 AFW FLOW FT-78

Stm Gen 3 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

unique System Desc:

SENS

1

POLY

Down

None

10

stream of Level control Valves

N/A

N/A

LOW

None

Wet

N/A

Page 3 of 52

ERDS Data Point Library (Rev 2)

Page 5: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:.

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

AX FD FL 4

FT79A

SG 1-4 AFW FLOW FT-79

Stm Gen 4 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

SENS

1

POLY

Down

None

N/A

N/A

Low

None

Wet

N/A

10

stream of Level Control Valves

Page 4 of 52

ERDS Data Point Library (Rev 2)

Page 6: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-t)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

124-0-1999

DC1

SPDS

H2 CONC

H2CONC

CONTAINMENT HYDROGEN CONCENTRATION

Containment Hydrogen Concentration

ANALOG

PCT

Volume - Percent

0

10

Revision 8

N/A

PROC

2

HMAX

Containment

N/A

N/A

N/A

Low

N/A

N/A

Standby service

Page 5 of 52

ERDS Data Point Ubrary (Rev 2)

Page 7: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG LEVEL 1

L0403A

SG 1-1 WIDE RANGE LEVEL

Steam Generator 1 Water Level

ANALOG

PCT

2.1%/Ft

0

100

Revision 12

3Ft above tube sheet

SENS

1

POLY

S/G 1

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 6 of 52

ERDS Data Point Ubrary (Rev 2)

Page 8: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG LEVEL 2

L0423A

SG 1-2 WIDE RANGE LEVEL

Steam Generator 2 Water Level

ANALOG

PCT

2.1%/Ft

0

100

Revision 9

3Ft above tube sheet

SENS

1

POLY

S/G 2

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 7 of 52

ERDS Data Point Ubrary (Rev 2)

Page 9: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG LEVEL 3

L0443A

SG 1-3 WIDE RANGE LEVEL

Steam Generator 3 Water Level

ANALOG

PCT

2. 1%/Ft

0

100

Revision 9

3Ft above tube sheet

SENS

1

POLY

S/G 3

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 8 of 52

ERDS Data Point Library (Rev 2)

Page 10: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG LEVEL 4

L0463A

SG 1-4 WIDE RANGE LEVEL

Steam Generator 4 Water Level

ANALOG

PCT

2.1%/Ft

0

100

Revision 12

3Ft above tube sheet

SENS

1

POLY

S/G 4

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 9 of 52

ERDS Data Point Library (Rev 2)

Page 11: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

COND A/E RAD

RM15A

S3AE GAS MON RE-15

condenser Air Ejector Radioactivity

ANALOG

CPM

N/A

10

1000000

Revision 11

N/A

SENS

1

SALG

A/E discharge to Plant Vent.

1000

N/A

N/A

Low

N/A

N/A

HALM SetPt. Based on 50 GPD Pri/Sec Leakage. Actual plant setting changes, but should be within 100 - 1000 CPM.

Page 10 of 52

ERDS Data Point Library (Rev 2)

Page 12: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion;

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG BD RAD

RM19A

SG BLOWDOWN RAD MON RE-19

Stm Gen Blowdown Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 6

N/A

SENS

1

SALG

S/G Blowdown sample common header

DC1 = 700, DC2 = 2500

N/A

N/A

Low

N/A

N/A

N/A

Page 11 of 52

ERDS Data Point Library (Rev 2)

Page 13: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

MAIN SL 1

RM71A

SG 1-1 STEAM LEAD RAD MON RE-71

Stm Gen 1 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 9

N/A

SENS

1

SALG

outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 12 of 52

ERDS Data Point Library (Rev 2)

Page 14: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

MAIN SL 2

RM72A

SG 1-2 STEAM LEAD RAD MON RE-72

Stm Gen 2 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 9

N/A

SENS

1

SALG

outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 13 of 52

ERDS Data Point Ubrary (Rev 2)

Page 15: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Anal og/Di gi tal:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12 -10-1999

DC1

SPDS

MAIN SL 3

RM73A

SG 1-3 STEAM LEAD RAD MON RE-73

Stm Gen 3 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 9

N/A

SENS

1

SALG

outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 14 of 52

ERDS Data Point Library (Rev 2)

Page 16: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point XD:

Plant Spec Point Desc:

Generic/Cond Desc:

Anal og/Digi tal :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

MAIN SL 4

RM74A

SG 1-4 STEAM LEAD RAD MON RE-74

Stm Gen 4 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 9

N/A

SENS

1

SALG

Outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 15 of 52

ERDS Data Point Ubrary (Rev 2)

Page 17: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Anal og/Digi tal :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

CL TEMP 1

T0406A

RCS LOOP 1-1 TCOLD

Stm Gen 1 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 14

N/A

SENS

1

POLY

RCP 1 Discharge

None

N/A

N/A

Low

N/A

N/A

N/A

Page 16 of 52

ERDS Data Point Ubrary (Rev 2)

Page 18: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA .POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

HL TEMP 1

T0419A

RCS LOOP 1-1 THOT

Stm Gen 1 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 12

N/A

SENS

1

POLY

Loop 1 Hot Leg

None

N/A

N/A

Low

N/A

N/A

N/A

Page 17 of 52

ERDS Data Point Library (Rev 2)

Page 19: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

CL TEMP 2

T0426A

RCS LOOP 1-2 TCOLD

Stm Gen 2 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 14

N/A

SENS

1

POLY

RCP 2 Discharge

None

N/A

N/A

LOW

N/A

N/A

N/A

Page 18 of 52

ERDS Data Point Ubrary (Rev 2)

Page 20: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

HL TEMP 2

T0439A

RCS LOOP 1-2 THOT

Stm Gen 2 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 12

N/A

SENS

1

POLY

Loop

None

2 Hot Leg

N/A

N/A

Low

N/A

N/A

N/A

Page 19 of 52

ERDS Data Point Ubrary (Rev 2)

Page 21: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCI

SPDS

CL TEMP 3

T0446A

RCS LOOP 1-3 TCOLD

Stm Gen 3 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 14

N/A

SENS

1

POLY

RCP 3 Discharge

None

N/A

N/A

LOW

N/A

N/A

N/A

Page 20 of 52

ERDS Data Point Ubrary (Rev 2)

Page 22: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

HL TEMP 3

T0459A

RCS LOOP 1-3 THOT

Stm Gen 3 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 13

N/A

SENS

1

POLY

Loop

None

N/A

N/A

Low

N/A

N/A

N/A

3 Hot Leg

Page 21 of 52

ERDS Data Point Library (Rev 2)

Page 23: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

CL TEMP 4

T0466A

RCS LOOP 1-4 TCOLD

Stm Gen 4 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 13

N/A

SENS

1

POLY

RCP 4 Discharge

None

N/A

N/A

LOW

N/A

N/A

N/A

Page 22 of 52

ERDS Data Point Library (Rev 2)

Page 24: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

HL TEMP 4

T0479A

RCS LOOP 1-4 THOT

Stm Gen 4 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 12

N/A

SENS

1

POLY

Loop

None

N/A

4 Hot Leg

N/A

Low

N/A

N/A

N/A

Page 23 of 52

ERDS Data Point Ubrary (Rev 2)

Page 25: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SUB MARGIN

T2805A

SUB COOLED MARGIN MONITOR

Saturation Temperature - Highest CET

ANALOG

DEGF

N/A

-40

200

Revision 12

N/A

SENS

1

POLY

N/A

LO =

N/A

N/A

Low

N/A

N/A

N/A

30 degF, LO-LO = 20 degF

Page 24 of 52

ERDS Data Point Library (Rev 2)

Page 26: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Gene ri c/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

PRZR LEVEL

X00003

PZR LVL - MIDDLE OF THE SCALE VALUES

Primary System Pressurizer Level

ANALOG PCT

N/A

0

100

Revision 9

Top of Heaters = 17%

PROC

3

SMID

PZR

HI = 70%, LO (letdown ISO) = 17%

N/A

N/A

LOW

N/A

Wet

Median signal of three Xmitters.

Page 25 of 52

ERDS Data Point Library (Rev 2)

Page 27: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-I)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

HOW Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

TEMP CORE EX

X00008

INCORE T/C MAX - HOTTEST TRAIN

Highest Temperature at the Core Exit

ANALOG

DEGF

N/A

0

2300

Revision 11

N/A

PROC

65

HMAX

Top of Rx Core

700 degF

N/A

N/A

Low

N/A

N/A

N/A

Page 26 of 52

FRDS Data Point Library (Rev 2)

Page 28: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

minimum Instr Range:

maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

REAC VES LEV

X00012

REACTOR VESSEL LEVEL

Reactor Vessel Water Level

ANALOG

PCT

N/A

0

120

Revision 10

Bottom of Vessel

PROC

2

EXTR

Reactor Vessel

Dependent on number of running RCP's

N/A

N/A

Low

Yes

Wet

100% = Top of vessel plus flow head.

Page 27 of 52

ERDS Data Point Ubrary (Rev 2)

Page 29: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or.SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

CTMNT PRESS

X00025

CONTAINMENT WR MAX PRESSURE

Containment Pressure

ANALOG

PSIG

N/A

-5

200

Revision 9

N/A

PROC

2

HMAX

Inside containment

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 28 of 52

ERDS Data Point Library (Rev 2)

Page 30: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-I)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCI

SPDS

NI POWER RNG

X00028

MAXIMUM POWER RANGE FLUX

Nuclear Instruments, Power Range

ANALOG

PCT

N/A

0

120

Revision 6

N/A

PROC

4

EXTR

4 quadrants surrounding Rx vessel

109%

N/A

N/A

Low

N/A

N/A

N/A

Page 29 of 52

ERDS Data Point Library (Rev 2)

Page 31: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-I)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

NI INTER RNG

X00031

MAXIMUM INTERMEDIATE RANGE AMPS

Nuclear Instruments, Intermediate Range

ANALOG

AMP

N/A

0.00000000001

0.001

Revision 7

N/A

PROC

2

EXTR

opposite sides of Rx vessel

Reactor Trip 0 25%

N/A

N/A

Low

N/A

N/A

N/A

Page 30 of 52

ERDS Data Point Library (Rev 2)

Page 32: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

NI SOURCE RNG

X00035

MAXIMUM SOURCE RANGE COUNTS

Nuclear Instruments, Source Range

ANALOG

CPS

counts per second

1

1000000

Revision 6

N/A

PROC

2

HMAX

opposite sides of Rx Vessel

Reactor Trip G 100000

1.1E-10 (P6 Setpoint)

6E-11 (P6 Reset)

Low

N/A

N/A

N/A

Page 31 of 52

ERDS Data Point Ubrary (Rev 2)

Page 33: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

CTMNT RAD

X00039

MAXIMUM CONTAINMENT HI RAD

Radiation Level in the containment

ANALOG

MR/HR

N/A

0.1

10000

Revision 6

N/A

PROC

1

EXTR

Containment Interior wall at access leve

21

N/A

N/A

Low

N/A

N/A

N/A

Page 32 of 52

ERDS Data Point Ubrary (Rev 2)

Page 34: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Anal og/Di gital :

Engr Units/Dig States:

Engr Units Conversion:

minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

EFF GAS RAD

X00045

MAX PLANT VENT GAS

Radioactivity of Released Gases

ANALOG

uCi/cc

N/A

0.22

Revision 9

N/A

PROC

2

HMAX

Plant Vent sample discharge

0.00091

N/A

N/A

Low

N/A

N/A

Inst. Range and indication calculated based on detector's MEl and 1E7 CPM output.

Page 33 of 52

ERDS Data Point Library (Rev 2)

Page 35: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG PRESS 1

X00056

SG 1-1 STEAM PRESS

Steam Generator 1 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 1

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 34 of 52

ERDS Data Point Library (Rev 2)

Page 36: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Anal og/Di gi tal :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG PRESS 2

X00057

SG 1-2 STEAM PRESS

Steam Generator 2 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 2

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 35 of 52

ERDS Data Point Library (Rev 2)

Page 37: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

SG PRESS 3

X00058

SG 1-3 STEAM PRESS

Steam Generator 3 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 3

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 36 of 52

ERDS Data Point Library (Rev 2)

Page 38: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-l)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCZ

SPDS

SG PRESS 4

X00059

SG 1-4 STEAM PRESS

Steam Generator 4 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 4

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 37 of 52

ERDS Data Point Ubrary (Rev 2)

Page 39: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

CTMNT SMP WR

X00063

CONTAINMENT WR LEVEL

Containment Sump wide Range Level

ANALOG

FT EL

N/A

64

98

Revision 4

Bottom of Rx cavity Sump

PROC

2

HMAX

Containment Sump

None

N/A

N/A

LOW

None

Dry

N/A

Page 38 of 52

ERDS Data Point Ubrary (Rev 2)

Page 40: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

RCS CHG/MU

x00069

CHARGING FLOW

Primary system charging or Makeup Flow

ANALOG

GPM

N/A

0

1000

Revision 6

N/A

PROC

1

EX'R

Downstream of CCP's

None

N/A

N/A

Low

None

N/A

N/A

Page 39 of 52

ERDS Data Point Ubrary (Rev 2)

Page 41: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

12-10-1999

DC1

SPDS

BWST LEVEL

X00072

MINIMUM RWST LEVEL

Borated Water Storage Tank Level

ANALOG PCT

INWC dP - PCT

0

100

Revision

N/A

PROC

2

HMIN

RWST

RHR Pump

8

Trip G 33% Level

N/A

N/A

Low

None

Level Reference Leg:

Unique System Desc:Dry

A minimum contained borated water volume of 400,000 gals.

Page 40 of 52

ERDS Data Point Library (Rev 2)

Page 42: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

RCS PRESSURE

X00092

RCS PRESSURE

Reactor Coolant System Pressure

ANALOG

PSIG

N/A

0

3000

Revision 4

N/A

PROC

2

HAVE

Hot Leg 3/4

None

N/A

N/A

LOW

N/A

N/A

N/A

Page 41 of 52

ERDS Data Point Library (Rev 2)

Page 43: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

MN FD FL 1

X00165

SG 1-1 FEED FLOW

Stm Gen 1 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector PowerSupply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

6

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

Low

None

N/A

N/A

Page 42 of 52

ERDS Data Point Library (Rev 2)

Page 44: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

MN FD FL 2

X00166

SG 1-2 FEED FLOW

Stm Gen 2 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision 6

N/A

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

LOW

None

N/A

N/A

Page 43 of 52

ERDS Data Point Library (Rev 2)

Page 45: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-l)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

MN FD FL 3

X00167

SG 1-3 FEED FLOW

Stm Gen 3 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision 6

N/A

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

Low

None

N/A

N/A

Page 44 of 52

ERDS Data Point Library (Rev 2)

Page 46: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unlt-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

MN FD FL 4

X00168

SG 1-4 FEED FLOW

Stm Gen 4 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - ibm/Hr

0

4200000

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

6

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

Low

None

N/A

N/A

Page 45 of 52

ERDS Data Point Ubrary (Rev 2)

Page 47: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

CORE FLOW

X00241

NUMBER OF RCPS RUNNING

Total Reactor Coolant Flow

ANALOG

NONE

N/A

0

4

Revision 6

N/A

PROC

2

EXTR

N/A

N/A

N/A

N/A

LOW

N/A

N/A

Point Pumps

indicates number of Reactor Coolant Running

Page 46 of 52

ERDS Data Point Library (Rev 2)

Page 48: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DCl

SPDS

HP SI FLOW

X00250

TOTAL SAFETY INJECTION FLOW

High Pressure Safety Injection Flow

ANALOG

GPM

INWC - GPM

0

1600

Revision 4

N/A

PROC

1 EXTR

Upstream of SI Xtie

N/A

N/A

N/A

Low

None

N/A

N/A

Page 47 of 52

ERDS Data Point Ubrary (Rev 2)

Page 49: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

HOW Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

LP SI FLOW

X00251

TOTAL RHR FLOW

Low Pressure Safety Injection Flow

ANALOG

GPM

INWC - GPM

0

10000

Revision 4

N/A

PROC

1

EXTR

Hot Leg Inj. Downstream of RHR HX's

None

N/A

N/A

Low

None

N/A

Residual Heat Removal Flow

Page 48 of 52

ERDS Data Point Ubrary (Rev 2)

Page 50: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-1)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations.:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999 DC1

SPDS

CTMNT TEMP

Y07OIA

CONTAINMENT TEMPERATURE

Containment Temperature

ANALOG

DEGF

N/A

0

400

Revision 10

N/A

SENS

2

POLY

N/A

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 49 of 52

ERDS Data Point Ubrary (Rev 2)

Page 51: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

HoW Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1

SPDS

WIND SPEED

UWINDSPD

BEST ERDS WIND SPEED

wind speed at the Reactor Site

ANALOG

M/S

mph - M/S

0

44.7

Revision 3

N/A

PROC

2

EXTR

N/A

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 50 of 52

ERDS Data Point Library (Rev 2)

Page 52: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-i)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point .Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC1 SPDS

WIND DIR

UWINDDIR

BEST ERDS WIND DIRECTION

wind Direction at the Reactor Site

ANALOG

DEG

N/A

0

360

Revision 3

True North = 0/360

PROC

2

EXTR

Met Tower 0 10M and 76M

N/A

N/A

N/A

Low

N/A

N/A

wind is FROM this direction

Page 51 of 52

ERDS Data Point Library (Rev 2)

Page 53: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-l)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC1

SPDS

STAB CLASS

UWINDSTB

BEST ERDS STABILITY

Air stability at the Reactor Site

ANALOG

standard

0

8

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

Stability Class A-G = 1-7

1

PROC

2

EXTR

N/A

N/A

N/A

N/A

LOW

N/A

N/A

vertical stability deviation from dT and standard deviation of wind direction. Standard Pasquill stability class A-G = 1-7.

Page 52 of 52

ERDS Data Point Ubrary (Rev 2)

Page 54: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

AX FD FL 1

FT5OA

SG 2-1 AFW FLOW FT-50

Stm Gen 1 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

SENS

1

POLY

Down

None

16

stream of Level Control Valves

N/A

N/A

Low

None

Wet

N/A

Page 1 of 52

ERDS Data Point Ubrary (Rev 2)

Page 55: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

AX FD FL 2

FT77A

SG 2-2 AFW FLOW FT-77

Stm Gen 2 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

SENS

1

POLY

Down

None

N/A

N/A

Low

None

Wet

N/A

13

stream of Level Control Valves

Page 2 of 52

ERDS Data Point Ubrary (Rev 2)

Page 56: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

AX FD FL 3

FT78A

SG 2-3 AFW FLOW FT-78

Stm Gen 3 Auxiliary FW Flow

ANALOG

GPM

INWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

.Unique System Desc:

SENS

1

POLY

Down

None

13

stream of Level Control Valves

N/A

N/A

Low

None

Wet

N/A

Page 3 of 52

ERDS Data Point Library (Rev 2)

Page 57: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

AX FD FL 4

FT79A

SG 2-4 AFW FLOW FT-79

Stm Gen 4 Auxiliary FW Flow

ANALOG

GPM

iNWC dP - GPM

0

320

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

SENS

1

POLY

Down

None

13

stream of Level Control valves

N/A

N/A

Low

None

Wet

N/A

Page 4 of 52

ERDS Data Point Library (Rev 2)

Page 58: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

H2 CONC

H20ONC

CONTAINMENT HYDROGEN CONCENTRATION

Containment Hydrogen Concentration

ANALOG PCT

Volume - Percent

0

10

Revision 4

N/A

PROC

2

HMAX

Containment

N/A

N/A

N/A

LOW

N/A

N/A

Standby service

Page 5 of 52

ERDS Data Point Library (Rev 2)

Page 59: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG LEVEL 1

L0403A

SG 2-1 WIDE RANGE LEVEL

Steam Generator 1 Water Level

ANALOG PCT

2.1%/Ft

0

100

Revision 13

3Ft above tube sheet

SENS

1

POLY

S/G 1

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 6 of 52

ERDS Data Point Library (Rev 2)

Page 60: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG LEVEL 2

L0423A

SG 2-2 WIDE RANGE LEVEL

Steam Generator 2 Water Level

ANALOG

PCT

2.1%/Ft

0

100

Revision 12

3Ft above tube sheet

SENS

1

POLY

S/G 2

None

N/A

N/A

Low

None

Wet

Top of S/G tubes = 69%

Page 7 of 52

ERDS Data Point Library (Rev 2)

Page 61: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG LEVEL 3

L0443A

SG 2-3 WIDE RANGE LEVEL

Steam Generator 3 Water Level

ANALOG PCT

2.1 /Ft

0

100

Revision 12

3Ft above tube sheet

SENS

1

POLY

S/G 3

None

N/A

N/A

LOW

None

Wet

Top of S/G tubes = 69%

Page 8 of 52

ERDS Data Point Ubrary (Rev 2)

Page 62: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG LEVEL 4

L0463A

SG 2-4 WIDE RANGE LEVEL

Steam Generator 4 Water Level

ANALOG

PCT

2.1%/Ft

0

100

Revision 15

3Ft above tube sheet

SENS

1

POLY

S/G 4

None

N/A

N/A

Low

None

Wet

Top of S/G tubes = 69%

Page 9 of 52

ERDS Data Point Ubrary (Rev 2)

Page 63: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

COND A/E RAD

RM15A

S3AE GAS MON RE-15

condenser Air Ejector Radioactivity

ANALOG

CPM

N/A

10

1000000

Revision 12

N/A

SENS

1

SALG

A/E discharge to Plant Vent.

1000

N/A

N/A

Low

N/A

N/A

HALM SetPt. Based on 50 GPD Pri/Sec Leakage. Actual plant setting changes, but should be within 100 - 1000 CPM.

Page 10 of 52

Diablo Canyon Power Plant (Unit-2) ERDS Data Point Library (Rev 2)

Page 64: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG BD RAD

RM19A

SG BLOWDOWN RAD MON RE-19

Stm Gen Blowdown Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 11

N/A

SENS

1

SALG

S/G Blowdown sample common header

DC1 = 700, DC2 = 2500

N/A

N/A

Low

N/A

N/A

N/A

Page 11 of 52

ERDS Data Point Library (Rev 2)

Page 65: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MAIN SL 1

RM71A

SG 2-1 STEAM LEAD RAD MON RE-71

Stm Gen 1 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 12

N/A

SENS

1

SALG

outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 12 of 52

ERDS Data Point Library (Rev 2)

Page 66: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MAIN SL 2

RM72A

SG 2-2 STEAM LEAD RAD MON RE-72

Stm Gen 2 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 12

N/A

SENS

1

SALG

Outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 13 of 52

ERDS Data Point Library/(Rev 2)

Page 67: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MAIN SL 3

RM73A

SG 2-3 STEAM LEAD RAD MON RE-73

Stm Gen 3 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 12

N/A

SENS

1

SALG

Outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 14 of 52

ERDS Data Point Library (Rev 2)

Page 68: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MAIN SL 4

RM74A

SG 2-4 STEAM LEAD RAD MON RE-74

Stm Gen 4 Steam Line Rad Level

ANALOG

CPM

Counts per Minute

10

1000000

Revision 12

N/A

SENS

1

SALG

outside containment near steam lead

1000

N/A

N/A

Low

N/A

N/A

N/A

Page 15 of 52

ERDS Data Point Library (Rev 2)

Page 69: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CL TEMP 1

T0406A

RCS LOOP 2-1 TCOLD

Stm Gen 1 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 16

N/A

SENS

1

POLY

RCP 1 Discharge

None

N/A

N/A

Low

N/A

N/A

N/A

Page 16 of 52

ERDS Data Point Ubrary (Rev 2)

Page 70: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12 -10-1999

DC2

SPDS

HL TEMP 1

T0419A

RCS LOOP 2-1 THOT

Stm Gen 1 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 15

N/A

SENS

1

POLY

Loop

None

1 Hot Leg

N/A

N/A

Low

N/A

N/A

N/A

Page 17 of 52

ERDS Data Point Ubrary (Rev 2)

Page 71: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CL TEMP 2

T0426A

RCS LOOP 2-2 TCOLD

Stm Gen 2 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 16

N/A

SENS

1

POLY

RCP 2 Discharge

None

N/A

N/A

Low

N/A

N/A

N/A

Page 18 of 52

ERDS Data Point Library (Rev 2)

Page 72: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unlt-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

HL TEMP 2

T0439A

RCS LOOP 2-2 THOT

Stm Gen 2 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 15

N/A

SENS

1

POLY

Loop

None

2 Hot Leg

N/A

N/A

LOW

N/A

N/A

N/A

Page 19 of 52

ERDS Data Point Library (Rev 2)

Page 73: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CL TEMP 3

T0446A

RCS LOOP 2-3 TCOLD

Stm Gen 3 Outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 16

N/A

SENS

1

POLY

RCP 3 Discharge

None

N/A

N/A

Low

N/A

N/A

N/A

Page 20 of 52

ERDS Data Point Ubrary (Rev 2)

Page 74: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

HL TEMP 3

T0459A

RCS LOOP 2-3 THOT

Stm Gen 3 Inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 16

N/A

SENS

1

POLY

Loop

None

3 Hot Leg

N/A

N/A

Low

N/A

N/A

N/A

Page 21 of 52

ERDS Data Point Ubrary (Rev 2)

Page 75: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CL TEMP 4

T0466A

RCS LOOP 2-4 TCOLD

Stm Gen 4 outlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 15

N/A

SENS

1

POLY

RCP 4 Discharge

None

N/A

N/A

Low

N/A

N/A

N/A

Page 22 of 52

ERDS Data Point Library (Rev 2)

Page 76: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

HL TEMP 4

T0479A

RCS LOOP 2-4 THOT

Stm Gen 4 inlet Temperature

ANALOG

DEGF

N/A

0

700

Revision 15

N/A

SENS

1

POLY

Loop

None

N/A

N/A

Low

N/A

N/A

N/A

4 Hot Leg

Page 23 of 52

ERD$ Data Point Ubrary (Rev 2)

Page 77: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS .SUB MARGIN

T2805A

SUB COOLED MARGIN MONITOR

Saturation Temperature - Highest CET

ANALOG

DEGF

N/A

-40

200

Revision 13

N/A

SENS

1

POLY

N/A

LO = 30 degF, LO-LO - 20 degF

N/A

N/A

LOW

N/A

N/A

N/A

Page 24 of 52

ERDS Data Point Library (Rev 2)

Page 78: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For' D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

PRZR LEVEL

X00003

PZR LVL - MIDDLE OF THE SCALE VALUES

Primary System Pressurizer Level

ANALOG

PCT

N/A

0

100

Revision 9

Top of Heaters = 17%

PROC

3

SMID

PZR

HI = 70%, LO (letdown ISO) = 17%

N/A

N/A

Low

N/A

Wet

Median signal of three xmitters.

Page 25 of 52

ERDS Data Point Library (Rev 2)

Page 79: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

TEMP CORE EX

X00008

INCORE T/C MAX - HOTTEST TRAIN

Highest Temperature at the Core Exit

ANALOG

DEGF

N/A

0

2300

Revision 9

N/A

PROC

65

HMAX

Top of Rx Core

700 degF

N/A

N/A

Low

N/A

N/A

N/A

Page 26 of 52

ERDS Data Point Library (Rev 2)

Page 80: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

REAC VES LEV

X00012

REACTOR VESSEL LEVEL

Reactor Vessel Water Level

ANALOG

PCT

N/A

0

120

Revision 8

Bottom of Vessel

PROC

2

EXTR

Reactor Vessel

Dependent on number of running RCP's

N/A

N/A

Low

Yes

Wet

100% = Top of vessel plus flow head.

Page 27 of 52

ERDS Data Point Ubrary (Rev 2)

Page 81: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CTMNT PRESS

X00025

CONTAINMENT WR MAX PRESSURE

Containment Pressure

ANALOG

PSIG

N/A

-5

200

Revision 9

N/A

PROC

2

HMAX

Inside containment

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 28 of 52

ERDS Data Point Library (Rev 2)

Page 82: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Anal og/Di gi tal :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

NI POWER RNG

X00028

MAXIMUM POWER RANGE FLUX

Nuclear Instruments, Power Range

ANALOG

PCT

N/A

0

120

Revision 4

N/A

PROC

4

EXTR

4 quadrants surrounding Rx Vessel

109%

N/A

N/A

Low

N/A

N/A

N/A

Page 29 of 52

ERDS Data Point Ubrary (Rev 2)

Page 83: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

NI INTER RNG

X00031

MAXIMUM INTERMEDIATE RANGE AMPS

Nuclear Instruments, Intermediate Range

ANALOG

AMP

N/A

0.00000000001

0.001

Revision 5

N/A

PROC

2

EXTR

opposite sides of Rx vessel

Reactor Trip 0 25%

N/A

N/A

Low

N/A

N/A

N/A

Page 30 of 52

ERDS Data Point Ubrary (Rev 2)

Page 84: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

NI SOURCE RNG

X00035

MAXIMUM SOURCE RANGE COUNTS

Nuclear Instruments, Source Range

ANALOG

CPS

Counts per Second

1

1000000

Revision

N/A

PROC or SENS:

Number of Sensors:

HOW Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

4

PROC

2

HMAX

Opposite sides of Rx Vessel

Reactor Trip G 100000

1.1E-10 (P6 Setpoint)

6E-11 (P6 Reset)

Low

N/A

N/A

N/A

Page 31 of 52

ERDS Data Point Library (Rev 2)

Page 85: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CTMNT RAD

X00039

MAXIMUM CONTAINMENT HI RAD

Radiation Level in the containment

ANALOG

MR/HR

N/A

0.1

10000

Revision 6

N/A

PROC

1

EXTR

Containment Interior wall at access leve

21

N/A

N/A

LOW

N/A

N/A

N/A

Page 32 of 52

ERDS Data Point Ubrary (Rev 2)

Page 86: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr. Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

HOW Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

EFF GAS RAD

X00045

MAX PLANT VENT GAS

Radioactivity of Released Gases

ANALOG

uci/cc

N/A

0.000000022

0.22

Revision 8

N/A

PROC

2

HMAX

Plant Vent sample discharge

0.00091

N/A

N/A

Low

N/A

N/A

Inst. Range and indication calculated based on detector's MEl and 1E7 CPM output.

Page 33 of 52

ERDS Data Point Library (Rev 2)

Page 87: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG PRESS 1

X00056

SG 2-1 STEAM PRESS

Steam Generator 1 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 1

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 34 of 52

ERDS Data Point Library (Rev 2)

Page 88: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unlt-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:'

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG PRESS 2

X00057

SG 2-2 STEAM PRESS

Steam Generator 2 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 2

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 35 of 52

ERDS Data Point Library (Rev 2)

Page 89: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level :

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

SG PRESS 3

X00058

SG 2-3 STE.AM PRESS

Steam Generator 3 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

s/G 3

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 36 of 52

ERDS Data Point Ubrary (Rev 2)

Page 90: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12 -10-1999

DC2

SPDS

SG PRESS 4

X00059

SG 2-4 STEAM PRESS

Steam Generator 4 Pressure

ANALOG

PSIG

N/A

0

1200

Revision 6

N/A

PROC

2

HAVE

S/G 4

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 37 of 52

ERDS Data Point Library (Rev 2)

Page 91: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CTMNT SMP WR

X00063

CONTAINMENT WR LEVEL

Containment Sump Wide Range Level

ANALOG

FT EL

N/A

64

98

Revision 4

Bottom of Rx Cavity Sump

PROC

2

HMAX

Containment Sump

None

N/A

N/A

Low

None

Dry

N/A

Page 38 of 52

ERDS Data Point Library (Rev 2)

Page 92: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

RCS CHG/MU

X00069

CHARGING FLOW

Primary System charging or Makeup Flow

ANALOG

GPM

N/A

0

1000

Revision 4

N/A

PROC

1

EXTR

Downstream of CCP's

None

N/A

N/A

Low

None

N/A

N/A

Page 39 of 52

ERDS Data Point Library (Rev 2)

Page 93: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

BWST LEVEL

X00072

MINIMUM RWST LEVEL

Borated Water Storage Tank Level

ANALOG

PCT

INWC dP - PCT

0

100

Revision 8

N/A

PROC

2

HMIN

RWST

RHR Pump Trip 0 33% Level

N/A

N/A

LOW

None

Dry

A minimum contained borated water volume of 400,000 gals.

Page 40 of 52

ERDS Data Point Library (Rev 2)

Page 94: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital :

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

RCS PRESSURE

X00092

RCS PRESSURE

Reactor Coolant System Pressure

ANALOG

PSIG

N/A

0

3000

Revision 4

N/A

PROC

2

HAVE

Hot Leg 3/4

None

N/A

N/A

LOW

N/A

N/A

N/A

Page 41 of 52

ERDS Data Point Ubrary (Rev 2)

Page 95: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MN FD FL 1

X00165

SG 2-1 FEED FLOW

Stm Gen 1 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision 6

N/A

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

LOW

None

N/A

N/A

Page 42 of 52

ERDS Data Point Library (Rev 2)

Page 96: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

MN FD FL 2

X00166

SG 2-2 FEED FLOW

Stm Gen 2 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - ibm/Hr

0

4200000

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

6

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

Low

None

N/A

N/A

Page 43 of 52

ERDS Data Point Library (Rev 2)

Page 97: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

MN FD FL 3

X00167

SG 2-3 FEED FLOW

Stm Gen 3 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

6

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

LOW

None

N/A

N/A

Page 44 of 52

ERDS Data Point Ubrary (Rev 2)

Page 98: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

MN FD FL 4

X00168

SG 2-4 FEED FLOW

Stm Gen 4 Main Feedwater Flow

ANALOG

LB/HR

INWC dP - lbm/Hr

0

4200000

Revision 6

N/A

PROC

2

AVE

Downstream of FWRV's

N/A

N/A

N/A

Low

None

N/A

N/A

Page 45 of 52

ERDS Data Point Ubrary (Rev 2)

Page 99: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unlt-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CORE FLOW

X00241

NUMBER OF RCPS RUNNING

Total Reactor Coolant Flow

ANALOG

NONE

N/A

0

4

Revision 4

N/A

PROC

2

EXTR

N/A

N/A

N/A

N/A

Low

N/A

N/A

Poi nt Pumps

indicates number of Reactor Coolant Running

Page 46 of 52

ERDS Data Point Library (Rev 2)

Page 100: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

HP SI FLOW

X00250

TOTAL SAFETY INJECTION FLOW

High Pressure safety Injection Flow

ANALOG

GPM

INWC - GPM

0

1600

Revision 4

N/A

PROC

1

EXTR

Upstream of SI Xtie

N/A

N/A

N/A

Low

None

N/A

N/A

Page 47 of 52

EROS Data Point Library (Rev 2)

Page 101: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

LP SI FLOW

X00251

TOTAL RHR FLOW

Low Pressure safety Injection Flow

ANALOG

GPM

INWC - GPM

0

10000

Revision 4

N/A

PROC

1

EXTR

Hot Leg

None

Inj. Downstream of RHR HX's

N/A

N/A

Low

None

N/A

Residual Heat Removal Flow

Page 48 of 52

ERDS Data Point Ubrary (Rev 2)

Page 102: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

CTMNT TEMP

Y0701A

CONTAINMENT TEMPERATURE

Containment Temperature

ANALOG

DEGF

N/A

0

400

Revision 12

N/A

SENS

2

POLY

N/A

N/A

N/A

N/A

LOW

N/A

N/A

N/A

Page 49 of 52

ERDS Data Point Library (Rev 2)

Page 103: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12-10-1999

DC2

SPDS

WIND SPEED

UWINDSPD

BEST ERDS WIND SPEED

Wind Speed at the Reactor Site

ANALOG

M/S

mph - M/S

0

44.7

Revision 6

N/A

PROC

2

EXTR

N/A

N/A

N/A

N/A

Low

N/A

N/A

N/A

Page 50 of 52

ERDS Data Point Library (Rev 2)

Page 104: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure Mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

12 -10-1999

DC2

SPDS

WIND DIR

IMINDDIR

BEST ERDS WIND DIRECTION

Wind Direction at the Reactor Site

ANALOG

DEG

N/A

0

360

Revision 4

True North = 0/360

PROC

2

EXTR

Met Tower 0 10M and 76M

N/A

N/A

N/A

Low

N/A

N/A

wind is FROM this direction

Page 51 of 52

ERDS Data Point Ubrary (Rev 2)

Page 105: Special Report 99-05, Supplement 1, Emergency Response ... · PG&E Letter DCL-99-161 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket

Diablo Canyon Power Plant (Unit-2)

PWR DATA POINT LIBRARY REFERENCE FILE

Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Reference Point Notes:

Zero Point Reference:

12-10-1999

DC2

SPDS

STAB CLASS

UWINDSTB

BEST ERDS STABILITY

Air Stability at the Reactor Site

ANALOG

Standard

0

8

Revision

N/A

PROC or SENS:

Number of Sensors:

How Processed:

sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cutoff Power Level:

NI Detector Power Supply Turnon Level:

Instrument Failure mode:

Temperature Compensation For D/P Transmitters:

Level Reference Leg:

Unique System Desc:

Stability Class A-G = 1-7

3

PROC

2

EXTR

N/A

N/A

N/A

N/A

Low

N/A

N/A

Vertical stability deviation from dT and standard deviation of wind direction. Standard Pasquill stability class A-G = 1-7.

Page 52 of 52

ERDS Data Point Ubrary (Rev 2)