Specialised Fire Resistant
Door Hardware
Cl/SfB
(32.5) Ro8 (K2)
protecting against
smoke and fire
Contents
Fire and Smoke – Life Threatening Forces 2
Product Selector 4
Edge Protector 5
Letterplates 6 – 9
Wide Angle Viewer 10
Intumescent Protection Kits (locks, latches and hinges) 11
Concealed Door Closer Protection Kits 12
Additional Information 13
Comprehensive Support 14 – 15
Fire and smoke protection measures are an essential, life- saving precaution in a building. What’s more, they protect the property from the devastating consequences of the fire itself, and the damaging effects of hot and cold smoke. So it’s essential to get the product selection right, every time.
02/14
Lorient has a respected reputation for
designing and manufacturing a wide range
of products for fire and smoke containment.
Products are also designed with acoustic,
thermal and weather containment in mind,
as well as accessibility – so you can be
assured that a Lorient system provides an
integrated, cost-effective solution.
With 35 years’ experience and accumulated
knowledge, we pride ourselves on offering
ground-breaking innovations, underpinned by
technical excellence and exceptional quality.
Our dedicated R&D centre not only generates
successful product developments for Lorient;
it also allows us to work in partnership with
customers to develop and test their own
products too. Our indicative fire test furnace
is particularly popular, giving customers real
insight into their own products’ performance
and helping to save substantial testing costs.
Always keen to keep raising the bar, we are
committed to gaining third party certification
for our products wherever a suitable scheme
exists. Many products hold CERTIFIRE
certification, and we also hold approvals
from both the BBA and IFC.
We embrace the highest management
standards too, and hold both
BS EN ISO 9001:2008 and
BS EN ISO 14001:2004 certificates for
our quality and environmental management
systems. Achieving ISO 14001 is just one
part of our ongoing commitment to operate
in a sustainable way: many initiatives are
planned and already underway to reduce
materials and energy usage, as well
as waste.
In addition to our UK and Europe head office,
we have a number of operations around
the world; in North America, Hong Kong,
Singapore and Australia. Furthermore, we
have strong links in India and the Middle
East, which means that we’re able to deliver
the right solutions locally to our customers
throughout the world. By keeping abreast
of technical developments and changes to
codes, regulations and standards across
the continents, we can ensure we’re always
providing the highest level of expertise.
From advice to testing, new product
development to manufacture – we work best
in partnership with you.
2 SPECIALISED FIRE RESISTANT DOOR HARDWARE
On average 311 people are killed and 11,100 are injured* in fires each year in the UK alone. Many of the casualties are attributable to breathing the toxic products of combustion from a remote fire.
Fire and smoke also cause extensive damage to building fabric and contents. £2.52 billion* per annum is the estimated total of fire-related losses. The majority of these deaths, injuries and losses occur in buildings where fire and smoke protection measures have been inadequate.
Design Needs and Regulatory Requirements
When fire breaks out in a building the
threat is twofold. Firstly, there is the fire
itself and the hot smoke generated in the
immediate vicinity. Secondly, there is cold
smoke which will spread rapidly through
the building, threatening people and
property some distance from the fire.
The Building Regulations take both these
threats into account, and supporting
documents give criteria for how they
can be managed. Details can be found in
Approved Document B (England & Wales),
Technical Booklet E (N Ireland), and
Technical Handbook Section 2 (Scotland).
The Regulations require large buildings
to be divided into smaller fire and smoke
resistant ‘compartments’, to reduce the
risk of damage to the building as a whole
and also to save lives in the case of a fire.
Building a fire resistant wall or floor to
make a compartment is relatively simple.
However, building design becomes much
more complex when the compartments
need to be linked in some way – essential
to make the building usable. Every time an
aperture is cut into one of the compartment
boundaries (for example, to install a door
in a fire resistant wall, or to pass ductwork
through a wall or ceiling) the aperture
must be filled with something that will
preserve the fire and smoke integrity of the
compartment. That’s the role of Lorient’s
products – to work with the surrounding
elements of the building to ensure the fire
and smoke resistant compartments are
maintained. Our fire and smoke seals can
be fitted into fire rated doors; our glazing
products can be fitted into doors, screens
or fire rated partitions; our air transfer grilles
can be installed into doors, walls and ducts.
Fire and smoke protection products must
be tested to prove their performance –
and indeed, separate tests are required
for fire and smoke. Our products are all
extensively tested, and our test reports are
freely available on request. Just call our
Technical Services team on 01626 834252.
Fire Resistant Door Hardware
Fire rated doors often need additional items
of hardware installed to make them work
– locks, letterplates, door closers, security
viewers – as well as products to protect
them from damage. This brochure shows
our products that can safely be installed
into fire rated doors, without compromising
the fire and smoke integrity of the doorset.
Featured products include:
a range of door hardware items which
offer security and protection against
smoke and fire;
universal intumescent protection kits
available for door closers and other
ironmongery items;
durable door leaf edge protectors with
built-in acoustic, smoke and fire seals.
Relevant Standards
There are several British Standards which
relate to the products and solutions featured
in this brochure. They include:
BS 476 Pt. 22: 1987: Methods for
determination of the fire resistance of
non-loadbearing elements of construction;
BS 476 Pt.31.1: 1983: Methods for
measuring smoke penetration through
doorset and shutter assemblies;
BS 9999: 2008: Code of practice for fire
safety in the design, management and use
of buildings.
Fire and Smoke – Life Threatening Forces
Use of symbols
indicates that the product
detail shown provides protection
against fire
indicates that the product
detail shown provides protection
against cold smoke
indicates that the product featured
provides acoustic benefits
indicates in minutes the fire
protection provided by the product
*Source: Communities and Local Government Website 2012.
3SPECIALISED FIRE RESISTANT DOOR HARDWARE
Specialised Fire Resistant Door Hardware
product solutions
A
C
C
C
B
C
C
C
D
F
E
4 SPECIALISED FIRE RESISTANT DOOR HARDWARE
We’ve provided guidance throughout the product range for the different types of door hardware protection, along with the duration of protection achieved.
Internal Door Leaf
A Door Closer Protection Kits
30 and 60 minutes fire protection (see page 12)
B Edge Protector 30 and 60 minutes fire and smoke protection (see page 5)
C Hinge Protection Kits
30 and 60 minutes fire protection (see page 11)
C Hinge Protection Kits
30 and 60 minutes fire protection (see page 11)
D Wide Angle Viewer 30 minutes fire and smoke protection (see page 10)
E Lock and Latch Protection Kits
30 and 60 minutes fire and smoke protection (see page 11)
F Letterplates
Up to 60 minutes fire and smoke protection plus security features
(see pages 6 – 9)
Product Selector
External or Apartment Entry / Hotel Door Leaf
5SPECIALISED FIRE RESISTANT DOOR HARDWARE
Edge Protector
Some doors suffer severe damage to the leading edge due to
heavy volumes of pedestrian and wheeled traffic. New test evidence
means that our Edge Protector now incorporates the innovative
DS seal. Together they offer superior combined protection against
damage, fire, smoke, sound and germs.
Key benefits Protects door edges against impact damage, to retain
the door’s appearance.
Cost effective – it reduces the need to replace the door:
easy to fit to new or existing doors.
Fire resistance provided for 30 to 60 minute applications:
successfully fire and smoke tested to BS 476 Pt. 22: 1987
and BS 476 Pt. 31.1: 1983.
Superior acoustic performance is provided by the unique
dual fins on the DS seal – meeting the requirements of
Approved Document E.
Low frictional elastomeric fins of the DS seal enable ease
of door operation – meeting the requirements of Approved
Document M.
Hygienic – easy to wipe clean.
Low maintenance.
Our Door Edge Protectors are manufactured from heavy duty,
impact resistant vinyl material, with a textured finish to reduce
scuff marks. Available in two finishes, Hessian (textured) and
Falmouth (smoother with light stippling).
LP1504DS acoustic,
smoke and fire seal
Patented
Door leaf
TECHNICAL DETAILS
Door thickness: nom. 44mm and 54mm
Also incorporates a margin for inevitable
variations in door thicknesses up to 62mm
Standard leg lengths: from 32mm to 50mm
Max length: 2.4m
Edges: radius or square
double swing type also available
Use with: laminated softwood or hardwood, flaxboard or
particleboard or solid homogeneous particleboard doors
For pairs of doors, one door leaf should be fitted with a fire seal
only Edge Protector and the other should be fitted with a DS seal
Edge Protector. Brush type fire and smoke seals are also available.
Matching items can be supplied, including push plates, kick plates
and door panels.
RJ 4432R
32mm
12mm
44
mm
RJ 4432S
32mm
12mm
44
mm
RJ 5432S RJ 5432R12mm
32mm
54
mm
12mm
32mm
54
mm
DS door Edge Protector
Falmouth finish
6 SPECIALISED FIRE RESISTANT DOOR HARDWARE
Letterplates
Doors from common passageways to flats, apartments and offices are frequently required to be fire and smoke resistant. They may also need to be fitted with a letterplate. Fitting a ‘normal’ letterplate assembly would completely negate the fire and smoke resisting properties of a door.
We supply two fire and smoke resistant letterplate models. Our integrated fire/security letterplate can be fitted with a range of optional security devices.
Lorient fire and smoke resistant letterplates:
provide protection against fire and smoke at all temperatures
when fitted to previously tested door sets;
provide protection against cold smoke in line with the
requirements of BS 9999: 2008 and Approved Document B
to the Building Regulations.
Firemaster Fire and Smoke
Resistant Letterplate
RJS 29063
High Performance Fire, Smoke
and Security Letterplate
7SPECIALISED FIRE RESISTANT DOOR HARDWARE
312mm Overall Size
60
mm
80
mm
290mm
267mm
8mm250 x 40mm Sleeve Aperture
304mm Overall Size
55
mm
70
mm
285mm
271mm
5mm254 x 36mm Sleeve Aperture
RJ 8042F
RJ 8042S
RJ 8047F
RJ 8047S
RJ 8052F
RJ 8052S
This letterplate assembly has been tested in accordance with
the principles of BS 476: Pt. 20/22: 1987 and provides in excess
of 30 minutes fire resistance.
Like other letterplate designs in our range, the intumescent liner
is telescopic, making it suitable for different thicknesses of door.
Key benefits
Robust aluminium construction.
Tested with positive pressure and can be located in any area
of the door.
Nylon brush seals fitted to prevent vision through the letterplate
and provided draught proofing.
Security cowl is available to prevent vision through the letterplate
when open, and to inhibit manipulation of locks and bolts.
Firemaster Fire and Smoke
Resistant Letterplate
CF219
Letterplate manufactured by Paddock Fabrications Ltd.
Security Cowl RJ 290X063C
334mm
303mm
73m
m
TECHNICAL DETAILS
Max/min door thickness: 40mm – 70mm
External height: 70mm
External width: 304mm
Door aperture size: 285mm x 55mm
Finishes: silver anodised, polished silver or polished gold
Acoustic Performance
Under test conditions it has been demonstrated that the Firemaster letterplate does not cause any significant reduction to the overall acoustic performance of the solid core fire door to which it is fitted. For more detailed information please contact our Technical Services team on 01626 834252.
60m
m
Acoustic Performance
Under test conditions it has been demonstrated that the
Firemaster letterplate does not cause any significant
reduction to the overall acoustic performance of the solid
core fire door to which it is fitted. For more information please
contact our Technical Services team on 01626 834252.
9SPECIALISED FIRE RESISTANT DOOR HARDWARE
This high performance letterplate assembly has been tested
in accordance with BS 476: Pt. 22 1987 and provides more
than 60 minutes fire protection.
The letterplate assembly is internally sealed so that the unit will
not compromise the smoke integrity of the door when tested in
accordance with BS 476: Pt. 31: 1: 1983. It can also be supplied
with a range of optional security devices. Several models of this
letterplate are available to suit different thicknesses of door.
High Performance Fire, Smoke
and Security Letterplate
TECHNICAL DETAILS
Max/min door thickness: 42mm – 47mm: RJ 8042F or RJ 8042S
47mm – 52mm: RJ 8047F or RJ 8047S
52mm – 57mm: RJ 8052F or RJ 8052S
note: Suffix F indicates fire protection
Suffix S indicates fire and smoke protection
External height: 80mm
External width: 312mm
Door aperture size: 270mm x 60mm
Letter flaps: For 30 mins, silver or gold anodised. For 60 mins,
brushed stainless, brass or *powder coated steel; other finishes are
also available. * For internal use only (applicable to powder coated steel).
CF255
Manufactured by Royde & Tucker Ltd.
Security Cowl LP10 Lockable Post-box LP12Internal security Latch LP11
322mm
410m
m in
clu
din
g s
cre
w fix
ing a
rea
122m
m
320mm
78m
m
Optional Security Features
These items may be fitted at the same time as the letterplate
or at a later date.
Security Cowl
Prevents people seeing through an open letterplate.
Stops people trying to manipulate locks and bolts through
a letterbox.
Reduces the risk of occupants being attacked through
a letterbox aperture.
Security Latch
Locks the inner flap.
Post-box
This item is constructed from steel with welded seams.
Collects the post and keeps it secure.
Prevents damage from flammable or harmful items posted
through a letterplate.
57m
m
10 SPECIALISED FIRE RESISTANT DOOR HARDWARE
Wide Angle Viewer
RJ 3745
A one-way viewer which allows occupants to see and identify
callers. The viewer is supplied with an integral intumescent liner.
Tests prove the viewer can be fitted to 30 minute fire resistant
doors without compromising fire safety.
Key benefits
Allows callers to be seen and identified without opening the door.
Projects an image of the caller onto an etched glass screen
which can be easily viewed from a convenient distance. It’s not
necessary to have the eye so close to the viewer that there is a
risk of penetration from sharp objects.
Allows occupants to see out but does not allow callers to see in.
Provides fire resistance of 30 minutes when fitted to full size door
assemblies and tested in accordance with BS 476: Pt. 22: 1987.
Is available in silver, white, gold, black or bronze.
A wide viewing angle of 160°.
24mm 45mm
37
mm
External aspect
Integral Lorient
intumescent liner
Viewer
Internal aspect
Etched glass screen,
38mm diameter on
internal face
11SPECIALISED FIRE RESISTANT DOOR HARDWARE
All door furniture must be fitted in a way which ensures
the fire resisting properties of a door aren’t compromised.
In many instances it’s advised that ironmongery is bedded
in intumescent mastic or paste.
A quicker, easier, cleaner and more accurate solution is to
use shaped pads of intumescent material. We offer a range
of kits designed for use with:
hinges;
locks and latches;
concealed hydraulic door closers (see page 12).
Intumescent Protection Kits Hinge Protection Kits
We supply intumescent protection kits for commonly specified hinges.
These kits provide fire resistance of 30 minutes or 60 minutes
when fitted to full size door assemblies and tested in accordance
with BS EN 1363: Pt. 1: 1999.
Lock and Latch Protection Kits
If the lock or latch of a fire resistant door is unprotected, it inevitably
reduces the door’s fire protection performance. Lorient provides a
universal lock kit which enables family groups of mortise locks to be
incorporated in fire resistant door leaves, as well as a lock kit which
is available to suit larger lock sizes.
These kits provide fire resistance of 30 minutes or 60 minutes
when fitted to full size door assemblies and tested in accordance
with BS EN 1363: Pt. 1: 1999.
Hinge protection kit Lock and latch protection kit
Integral Lorient
intumescent liner
Hinge
Lock
Lorient
intumescent
lock jacket
Door leaf
Lorient
intumescent
lock and
latch plate
12 SPECIALISED FIRE RESISTANT DOOR HARDWARE
Hydraulic closers concealed in the door leaf are increasingly
popular – but they must not be fitted to fire resistant doors without
appropriate protective measures being taken. This is because:
they require a large portion of the door to be cut away which
immediately reduces fire resistance;
many models contain flammable hydraulic oil;
the aluminium housings are likely to melt in intense heat
leading to a breach;
they are made from materials which are very good heat
conductors and take up much of the available door leaf thickness.
Our intumescent protection kits overcome these problems.
They consist of a thin, high performance intumescent sheet,
pre-cut and scored so that they can be easily fitted around door
closers. The kits are self-adhesive for straightforward installation.
When tested in accordance with BS 476: Pt. 20/22: 1987 it was
shown that our closer protection kits can provide up to 60 minutes
protection, even on 44mm thickness door leaves.
The low pressure intumescent action ensures the door leaf is not
split. Insulation against heat transfer is provided as soon as the
intumescent material is activated.
Concealed Door Closer
Protection Kits
Door leaf
Lorient
intumescent
liner
Door closer
Door closer
head rail
Lorient
intumescent
liner
Partition wall
Frame head
13SPECIALISED FIRE RESISTANT DOOR HARDWARE
Handling and Storage
No special precautions are required when handling our specialised fire
resistant door hardware products but they should always be treated
with care. Our products should be stored in a clean, dry, dust-free
area away from heat and at a storage temperature no less than 5˚C.
Maintenance
Periodic inspection/cleaning is recommended for all products.
Worn or damaged products should be replaced without delay.
Trade Associations
Lorient is a founder member of the Intumescent Fire Seals
Association (IFSA) and a member of the Association of Interior
Specialists (AIS).
Lorient is also a member of the British Woodworking Federation
(BWF) (Associate); the Architectural and Specialist Door
Manufacturers Association (ASDMA); the Guild of Architectural
Ironmongers (GAI); and is also an Approved Supplier to the
BWF CERTIFIRE Fire Door and Doorset Scheme.
Technical References
Lorient is quality assured under the disciplines
of BS EN ISO 9001:2008.
Accreditation to this standard is a guarantee
that we conduct our business to the complete
satisfaction of our customers with regard to
design solutions, manufacturing consistency
and management procedures.
In addition, this internationally recognised standard for quality
management generates customer confidence and eliminates the risk
of poor performance. Regular audits of our company procedures are
undertaken by qualified BSI staff to ensure ongoing compliance with
all aspects of the standard.
Lorient has attained BS EN ISO 14001:2004
accreditation for environmental management,
making us the first seal manufacturer to
have achieved this important award. This
internationally recognised standard represents
that we have demonstrated our commitment
to responsible environmental behaviour, including prevention of
pollution, control and reduction of waste, and ongoing monitoring
and improvement of its environmental performance. Achieving
ISO 14001 is just one part of our ongoing commitment to operate
in a sustainable way.
Lorient’s products can also make an important contribution to
sustainability within a building’s construction: our acoustic, smoke
and fire seals can additionally provide thermal containment benefits,
aiding efficient energy management in a building.
Founder Member of the Intumescent Fire Seals
AssociationAssociation of
Interior Specialists
ISO9001QualityManagement
BS EN ISO 9001:2008 Certificate No. Q6104
ISO14001EnvironmentalManagement
BS EN ISO 14001:2004 Certificate No. EMS 541906
additional information
Intellectual Property
© 2014 Lorient Polyproducts Ltd – this brochure is protected by copyright and neither the
drawings nor the text may be reproduced or transmitted in any form without prior consent
from Lorient. Lorient products described in this brochure are protected by patents and design
registrations in Great Britain and other countries.
We are committed to continually enhancing and improving our product range. We reserve
the right to change product specifications from time to time without prior notice. E&OE.
Architectural and Specialist Door Manufacturers
Association
14 SPECIALISED FIRE RESISTANT DOOR HARDWARE
Continuing Professional Development Seminars
Performance Door Design: The Basics of Sound Reduction
Effective acoustic containment helps to
improve the quality of the built environment,
preserving privacy as well as excluding
unwanted noise. With changing regulations,
it’s essential to be informed of the relevant
requirements and the implications for
door assemblies.
Our acoustic CPD seminar covers:
the nature of sound, examining
airborne transmission of sound;
regulatory requirements and
British Standards that relate
to acoustic performance;
test procedures and interpretation
of test reports;
effective design of door assemblies
for acoustic performance, including
door construction and the influence
of sealing systems;
design conflicts between acoustic
performance, durability and ease
of operation of the door;
independent accreditation.
The Role and Performance of Fire and Smoke-Resisting Door Assemblies
The importance of fire and smoke resisting
door assemblies is illustrated by the 311 annual deaths in fire tragedies in the UK
alone. Apart from the human toll, property losses each year approach £2.52 billion.
Our fire and smoke containment CPD
seminar covers:
hard facts concerning deaths, injuries
and property damage caused by fire
and smoke;
regulatory requirements for fire and
smoke resisting door assemblies;
the nature and behaviour of smoke;
effective design of door assemblies
for smoke containment, including the
threshold gap;
design conflicts between fire containment,
smoke containment, durability and ease
of operation of the door;
independent accreditation.
The Regulatory Reform (Fire Safety) Order 2005 and its implications for fire doors
The RRO consolidated 70 pieces of
legislation; shifted responsibility for fire
safety management; abolished the Fire
Safety Certificate; established the Fire Risk
Assessment and created major change in
legal liability.
Our RRO CPD seminar covers:
an overview of the RRO;
product solutions;
the dangers of fire and smoke;
the importance of fire doors – including
installation and maintenance.
Our CPD materials have been independently
verified and certified by the RIBA as CPD
approved. A certificate for 1 hour’s CPD
will be provided, which contributes to
Continuing Professional Development
requirements.
If you’re interested in booking either
seminar, please contact our Marketing
department or e-mail [email protected].
We offer three fully-accredited CPD seminars. Impartially presented by knowledgeable speakers, the seminars are structured to be technically informative, and give practical advice.
15SPECIALISED FIRE RESISTANT DOOR HARDWARE
comprehensive support
We continue to lead the way in research and development: As a company we have nearly 35 years’ experience, so our experts are well equipped to listen, help and advise you on your acoustic, smoke and fire containment needs.
01626 834252 Call our Technical Services team on
www.lorientuk.com
Technical Services
We’re happy to provide specialist advice
on acoustic, smoke and fire protection
for refurbishment and new build projects.
If you need assistance, you can call our
Technical Services team.
Alternatively, we can arrange a site visit
to get a clearer idea of your needs and how
we can help you. We also provide copies
of test reports and samples where needed
and can give guidance on how best to meet
Building Regulations and Standards.
Customisation
If you have a particular requirement
which isn’t covered by the applications
in this brochure, we may be able to supply
an existing non-standard item, or even
develop a customised solution for you.
Testing Services
Lorient’s Testing & Technical Services
centre offers a variety of specialist testing
services for manufacturers and designers
of assemblies including doorsets, windows,
glazing systems and door hardware to
name but a few. Whether you’re
investigating new materials, or developing
new or existing products, right through
to durability testing and benchmarking
performance – our team of experts will
support you throughout the process.
Lorient Polyproducts Ltd
Endeavour House
Fairfax Road
Heathfield Ind Estate
Newton Abbot
Devon TQ12 6UD UK
www.lorientgroup.com UK and EuropeTel: +44 (0) 1626 834252 Fax: +44 (0) 1626 833166 email: [email protected]
USATel: +1 859 252 7441 Fax: +1 859 381 1241 [email protected]
Hong KongTel: +852 2505 0328 Fax: +852 2505 0332 email: [email protected] Singapore
Tel: +65 6270 1279 email: [email protected]
DubaiTel: +9714 883 7206
Fax: +9714 883 7207email: [email protected]
Australia Tel: +61 (02) 99076221email: [email protected]
LorientPolyproducts
@LorientUK
Lorient