+ All Categories
Home > Documents > Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF...

Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF...

Date post: 08-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
4
4/10/2019 HI-6122 Electric Field Probe http://www.ets-lindgren.com/datasheet/probes-monitors/emc-probes/electric-field-probes/9003/900305 1/4 ELECTRIC FIELD PROBES HI-6122 Electric Field Probe ETS-Lindgren's HI-6122 Electric Field Probe operates at a Frequency Range of 10 kHz to 1 GHz. ETS-Lindgren's Model HI-6122 RF Field Probe is a laser- powered probe that provides broadband EMF frequency coverage and wide dynamic range that satises the demands of most test requirements. To take advantage of this capability, the HI-6122 was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X, Y, Z) can be read individually or summed. Fiber optic signal and power lines link the Model HI-6122 eld probe to either the model HI-6100 Field Monitor, or as a direct connect to a PC with the HI-6113 Laser Data Interface and ProbeView™ Laser Software. The HI-6100 Field Monitor provides manual functions and programmed control via IEEE-488 and RS-232 Serial Data Interfaces. Readings from up to four probes can be displayed simultaneously. The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series eld probes as a Field Monitor in addition to its capability as a system level platform. The HI-6113 Laser Data Interface provides the laser power and communications for the HI-6122 Electric Field Probe. A USB connection to the PC allows for quick and easy data collection, using ProbeView Laser software. Key Features Laser Powered - Permits Extended Testing Laser Powered - Permits Extended Testing Frequency Range: 10 kHz to 1 GHz Frequency Range: 10 kHz to 1 GHz Dynamic Range 2.0 to 800 V/m (Single Dynamic Range 2.0 to 800 V/m (Single Range) Range) Provides Individual and Summed Axis Provides Individual and Summed Axis Values Values A2LA Accredited Calibration Report A2LA Accredited Calibration Report Suitable for MIL Standard Specs: Suitable for MIL Standard Specs: MIL-STD 461E Radiated Susceptibility (RS) MIL-STD 461E Radiated Susceptibility (RS) Suitable for Automotive Specs: Suitable for Automotive Specs: SAE J1113/27GMW 3091/3097/3103 SAE J1113/27GMW 3091/3097/3103 Suitable for Commercial Specs: Suitable for Commercial Specs: EN/IEC61000-4-3 EN/IEC61000-4-3 Radiated Immunity Radiated Immunity Operates with Most 3rd Party Immunity Operates with Most 3rd Party Immunity Software Software Specications
Transcript
Page 1: Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF frequency coverage and wide dynamic range that satises the demands of most test requirements.

4/10/2019 HI-6122 Electric Field Probe

http://www.ets-lindgren.com/datasheet/probes-monitors/emc-probes/electric-field-probes/9003/900305 1/4

ELECTRIC FIELD PROBES HI-6122 Electric Field Probe ETS-Lindgren's HI-6122 Electric Field Probe operates at a Frequency Range of 10 kHz to 1GHz.

ETS-Lindgren's Model HI-6122 RF Field Probe is a laser-powered probe that provides broadband EMF frequencycoverage and wide dynamic range that satis�es the demandsof most test requirements. To take advantage of this capability,the HI-6122 was designed to be single range reading so datacan be read continuously over the entire dynamic range. Datavalues for each axis (X, Y, Z) can be read individually orsummed.

Fiber optic signal and power lines link the Model HI-6122 �eldprobe to either the model HI-6100 Field Monitor, or as a directconnect to a PC with the HI-6113 Laser Data Interface andProbeView™ Laser Software.

The HI-6100 Field Monitor provides manual functions andprogrammed control via IEEE-488 and RS-232 Serial DataInterfaces. Readings from up to four probes can be displayedsimultaneously.

The EMCenter™ Modular RF Platform along with theEMSense™ interface card can be used with the HI-6000 series�eld probes as a Field Monitor in addition to its capability as asystem level platform.

The HI-6113 Laser Data Interface provides the laser power andcommunications for the HI-6122 Electric Field Probe. A USBconnection to the PC allows for quick and easy data collection,using ProbeView Laser software.

Key Features

Laser Powered - Permits Extended TestingLaser Powered - Permits Extended Testing

Frequency Range: 10 kHz to 1 GHz Frequency Range: 10 kHz to 1 GHz 

Dynamic Range 2.0 to 800 V/m (SingleDynamic Range 2.0 to 800 V/m (Single

Range)Range)

Provides Individual and Summed AxisProvides Individual and Summed Axis

Values Values 

A2LA Accredited Calibration ReportA2LA Accredited Calibration Report

Suitable for MIL Standard Specs:Suitable for MIL Standard Specs:

MIL-STD 461E Radiated Susceptibility (RS) MIL-STD 461E Radiated Susceptibility (RS) 

Suitable for Automotive Specs:Suitable for Automotive Specs:

SAE J1113/27GMW 3091/3097/3103 SAE J1113/27GMW 3091/3097/3103 

Suitable for Commercial Specs:Suitable for Commercial Specs:

EN/IEC61000-4-3 EN/IEC61000-4-3 

Radiated ImmunityRadiated Immunity

Operates with Most 3rd Party ImmunityOperates with Most 3rd Party Immunity

SoftwareSoftware

Speci�cations

Page 2: Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF frequency coverage and wide dynamic range that satises the demands of most test requirements.

4/10/2019 HI-6122 Electric Field Probe

http://www.ets-lindgren.com/datasheet/probes-monitors/emc-probes/electric-field-probes/9003/900305 2/4

Electrical Speci�cations

Detection:Detection: Isotropic (X, Y and Z Axis Readings) Frequency Response with Correction:Frequency Response with Correction: 10 kHz to 1 GHz ± 0.9 dB Frequency Range:Frequency Range: 10 kHz to 1 GHz Frequency Response: Frequency Response: 10 kHz to 30 kHz +0.5, -2.5 dB, 30 kHz to 1 GHz ± 1.0 dB Resolution:Resolution: 0.01 V/m Isotropic Deviation: Isotropic Deviation: ±0.5 dB @ 400 MHz dB Linearity: Linearity: ±0.5 dB    Sample Rate (Typical):Sample Rate (Typical): >70 Samples per Second Maximum    Overload Withstand:Overload Withstand: >1500 V/m CW

Physical Speci�cations

Physical Interface:Physical Interface: Duplex Optical Fiber (62.5 Micron Multimode)FC Connectors for Laser Cable, Integral 1m Optical CableST Connector for Transmitter Cable, Integral 1m Optical Cable

Operating Temperature Range: Operating Temperature Range: 10 to 40° C (50° to 104° F), 5 to 95% RelativeHumidity Non-condensingDimensions (Housing): Dimensions (Housing): 36 mm (1.42 in); 32 mm x 32 mm x 32 mm (1.26 in x 1.26 in x1.26 in) Mounting:Mounting: 1/4 in - 20 UNC Internal Thread

Other Speci�cations

ManualManualProbe AssemblyProbe AssemblyA2LA Traceable Calibration ReportA2LA Traceable Calibration Report10m Optical Cable10m Optical CableBulkhead Connector (2)Bulkhead Connector (2)Carrying CaseCarrying CaseFiber Cleaning Kit and SwabsFiber Cleaning Kit and Swabs

Page 3: Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF frequency coverage and wide dynamic range that satises the demands of most test requirements.

4/10/2019 HI-6122 Electric Field Probe

http://www.ets-lindgren.com/datasheet/probes-monitors/emc-probes/electric-field-probes/9003/900305 3/4

Product Charts

 

Page 4: Specications - MDL Technologies · 2019-04-10 · powered probe that provides broadband EMF frequency coverage and wide dynamic range that satises the demands of most test requirements.

4/10/2019 HI-6122 Electric Field Probe

http://www.ets-lindgren.com/datasheet/probes-monitors/emc-probes/electric-field-probes/9003/900305 4/4


Recommended