Specific Applications Documents Derived from the GUM
The following citations are for information purposes but are not necessarily endorsed by the members of JCGM/WG 1. This compilation is not meant to be exhaustive.
1992 1993 1994 1995 1996 1997 1998 1999 2000 2001
2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012
1992
Propagation of Variance in Dew Point and Psychrometer Humidity Gauges
G.D. Chapman
National Research Council of Canada, Ottawa, Canada
Metrologia, 1992, 29, 379-387.
1993
Uncertainty Modelling in Mass Comparisons
W. Bich, M.G. Cox and P.M. Harris
Istituto di Metrologia "G. Colonnetti", Turin, Italy
Metrologia, 1993/94, 30, 495-502.
1994
Quality Assessment for Wind Tunnel Testing
AGARD Advisory Report 304, Fluid Dynamics Panel Working Group 15, July 1994, Advisory Group for Aerospace Research & Development, Neuilly-sur-Seine, France.
Traceable Calibration and Uncertainty of Measurements in Scanning Electron Microscopy
Halldór Guðmundsson and Tómas P. Rúnarsson
NT Techn Report 252, 1994, Strategy Group on Quality and Metrology, Nordtest, Espoo, Finland.
The Treatment of Uncertainty in EMC Measurements
NIS 81, 1994 Edition, NAMAS Executive, National Physical Laboratory, Teddington, UK.
1995
Uncertainty of pH Measurements
H. Jensen and L. Nielsen
NT Techn Report 284, 1995, Nordtest, Espoo, Finland.
Statistical Descriptors in Crystallography. II. Report of a Working Group on Expression of Uncertainty in Measurement
D. Schwarzenbach et al.
Working Group of the International Union of Crystallography Commission on Crystallographic Nomenclature
Acta Cryst. A, 1995, 51, 565-569.
1996
Uncertainty of Atomic Absorption Spectrometry: Application to the Determination of Lead in Blood
J. Kristiansen, J. M. Christensen and J. L. Nielsen
Mikrochim. Acta, 1996, 123, 241-249.
Uncertainties Associated with Imperfect Surfaces in Thermal Conductivity Measurements using Standard Hot-Plate Equipment
NIS 83, 1996 Edition, NAMAS Executive, National Physical Laboratory, Teddington, UK.
1997
Gauge Block Calibration by Optical Interferometry at the National Research Council Canada
Jennifer E. Decker and James R. Pekelsky
NRC Doc. No. 40002, 1997, Institute for National Measurements Standards, National Research Council Canada.
See also Metrologia, 1997, 34, 479 – 493.
Uncertainty Evaluation for the Measurement of Gauge Blocks by Optical Interferometry
Jennifer E. Decker and James R. Pekelsky
NRC Doc. No. 41374, 1997, Institute for National Measurements Standards, National Research Council Canada.
Calibration of Oscilloscopes
Document EA-10/07 (previously EAL-G30), June 1997, European co-operation for Accreditation.
Calibration and Uncertainty of XRF measurements in the SEM
Halldór Guðmundsson
NT Techn Report 351, 1997, Nordtest, Espoo, Finland.
Measurement Uncertainty of Radiated Emissions
David A. Hill and Motohisa Kanda
NIST Technical Note 1389, March 1997, National Institute of Standards and Technology, Boulder, USA.
Uncertainty Analysis of Three-Dimensional Coordinate Measuring Machines
Jiro Matsuda
National Research Laboratory of Metrology, Tsukuba, Japan
Journal of Robotics and Mechatronics, 1997, 9, No. 2, 140-145.
1998
Uncertainty Analysis for Angle Calibrations using Circle Closure
Tyler W. Estler
National Institute of Standards and Technology, Gaithersburg, USA
J. Res. Natl. Inst. Stand. Technol., 1998, 103, 141-151.
Uncertainties in NIST Noise-Temperature Measurements
J. Randa
NIST Technical Note 1502, March 1998, National Institute of Standards and Technology, Boulder, USA.
A Practical Model for Uncertainty Evaluation in Force Measurements
C. Xu
National Measurement Centre, Singapore
Meas. Sci. Technol., 1998, 9, 1831-1836.
1999
Expression of the uncertainty of measurement in the calibration of thermometers. Part I: Standard Platinum Resistance Thermometers
I. Lira et al.
Metrologia, 1999, 36, 107-111.
Expression of the uncertainty of measurement in the calibration of thermometers. Part II: Thermocouples
I. Lira and P.R. Santos
Metrologia, 1999, 36, 415-419.
2000
27 exemples d'évaluation d'incertitudes d'étalonnage
Bibliothèque Qualité, Collège Métrologie du Mouvement Français pour la Qualité, Nanterre, France.
The Development of a Six-component Force/moment Sensor Testing Machine and Evaluation of its Uncertainty
Gab-Soon Kim
Gyeongsang National University, Kyungnam 660-701, Republic of Korea
Meas. Sci. Technol., 2000, 11, 1377-1382.
Uncertainty Evaluation of a Primary Shock Calibration Method for Accelerometers
K. Ueda, A. Umeda and H. Imai
National Research Laboratory of Metrology, Umezono, Tsukuba, Japan
Metrologia, 2000, 37, 187-197.
2001
Calibration of Impedances by the Substitution Method: Numerical Uncertainty Evaluation
L. Callegaro and W. Bich
Istituto Elettrotecnico Nazionale Galileo Ferraris, Turin, Italy; Istituto di Metrologia Gustavo Colonnetti, Turin, Italy
Proceedings of the 11th IMEKO TC-4 Symp., Trends in Electrical Measurement and Instrumentation, September 2001, Lisbon, Portugal. ISBN 972-98115-4-7.
Uncertainty contributions from mismatch in microwave measurements
T. Guldbrandsen
Technical University of Denmark, Lyngby, Denmark
IEE Proc.-Microw. Antennas Propag., 2001, 148, No. 6, 393-397.
Uncertainty Evaluation and Software Development for the Density Determination by Hydrostatic Weighing
R. Juma et al.
Advanced Mathematical & Computational Tools in Metrology v, Series on Advances in Mathematics for Applied Sciences - Vol. 57, 2001, pp 220 - 223, P. Ciarlini et al. Ed., World Scientific Publishing Co., Singapore.
Description of a Generally Applicable Model for the Evaluation of Uncertainty of Measurement in Clinical Chemistry
J. Kristiansen
National Institute of Occupational Health, Copenhagen, Denmark.
Clin. Chem. Lab. Med., 2001, 39, No. 10, 920-931.
Calculation of Measurement Uncertainty for Multi-dimensional Machines, Using the Method of Surrogate Data
B.W.J.J.A. Van Dorp et al.
Advanced Mathematical & Computational Tools in Metrology v, Series on Advances in Mathematics for Applied Sciences - Vol. 57, 2001, pp 344 - 351, P. Ciarlini et al. Ed., World Scientific Publishing Co., Singapore.
2003
Ejercicios de Estimación de Incertidumbres en mediciones
Centro Nacional de Metrología
http://www.cenam.mx/publicaciones/gratuitas/default.asp
Error propagation in fixed-point ellipsometric inversions
T. Easwarakhanthan and P. Pigeat
Meas. Sci. Technol., 2003, 14, 516–522.
Least-squares analysis of time series data and its application to two-way satellite time and frequency transfer measurements
P. M. Harris, J. A. Davis, M. G. Cox, S. L. Shemar
Metrologia, 2003, 40(3), S342-S347.
Quality assurance of qualitative analysis in the framework of the European project ‘MEQUALAN’
A. Ríos et al.
The European Commission has supported the G6MA-CT-2000-01012 project on “Metrology of Qualitative Chemical Analysis” (MEQUALAN), which was developed during 2000-2002.
Accred. Qual. Assur., 2003, 8, No. 2, 68-77.
Propagation of uncertainty for non-linear calibration equations with an application in radiation thermometry
P. Saunders
Metrologia, 2003, 40(2), 93-102.
A comprehensive analysis of the uncertainty of a commercial ozone photometer
M. Zucco, S. Curci, G. Castrofino and M. P. Sassi
Meas. Sci. Technol., 2003, 14, 1683–1689.
2004
Estimation of hygrometry uncertainties by propagation of distributions
V. Carpentier et al.
Metrologia, 2004, 41(6), 432-438.
Whole-field strain uncertainty evaluation by a Monte Carlo method
R. R. Cordero and P. Roth
Meas. Sci. Technol., 2004, 15, 1885–1891.
Considerations for the Evaluation of Measurement Uncertainty in Interferometric Gauge Block Calibration Applying Methods of Phase Step Interferometry
J. E. Decker, R. Schödel, G. Bönsch
Metrologia, 2004, 41(3), L11-L17.
Quantifying uncertainty in nuclear analytical measurements
International Atomic Energy Agency
IAEA-TECDOC-1401, July 2004
Uncertainty associated with virtual measurements from computational quantum chemistry models
K. K. Irikura, R. D. Johnson III, R. N. Kacker
Metrologia, 2004, 41(6), 369-375.
Uncertainty analysis of positional deviations of CNC machine tools
I. Lira and G. Cargill
Precision Engineering, 2004, 28, 232-239.
The uncertainty of experimental derivatives: application to strain measurement
I. Lira, R. R. Cordero, M. François, C. Vial-Edwards
Meas. Sci. Technol., 2004, 15, 2381–2388.
Revision and uncertainty evaluation of a primary dewpoint generator
J. Nielsen and M. J. de Groot
Metrologia, 2004, 41(3), 167-172.
Uncertainty in audiometer calibration
M. A. Pedroso, S. N. Y. Gerges, A. A. Jr. Gonçalves
Metrologia, 2004, 41(1), 1-7.
2005
Quantitative magnetic resonance spectroscopy: Semiparametric modeling and determination of uncertainties.
C. Elster, F. Schubert, A. Link, M. Walzel, F. Seifert and H. Rinneberg (2005).
Magn. Reson. Med. 53, 1288-1296.
Analysis of the uncertainty in the measurement of electron densities in plasmas using the wave cutoff method
J.-H. Kim, K.-H. Chung, Y.-H. Shin
Metrologia, 2005, 42(2), 110-114.
Measurement error analysis and uncertainty reduction for period- and time-interval-to-digital converters based on microcontrollers
S. Y. Yurish, F. Reverter and R. Pallàs-Areny
Meas. Sci. Technol., 2005, 16, 1660–1666.
2006
Evaluation of the air density uncertainty: the effect of the correlation of input quantities and higher order terms in the Taylor series expansion
L. O. Becerra and I. Hernández
Meas. Sci. Technol., 2006, 17, 2545–2550.
SIE and OME as tools to estimate the uncertainty in the correction for the effect of impurities applied to metal-carbon eutectic systems
P. Bloembergen and Y. Yamada
Metrologia, 2006, 43(5), 371-382.
Analysis of uncertainties in thermophysical parameters of materials obtained from a periodic method
A. Boudenne, L. Ibos and Y. Candau
Meas. Sci. Technol., 2006, 17, 1870–1876.
Surface fitting taking into account uncertainty structure in coordinate data
A. B. Forbes
Meas. Sci. Technol., 2006, 17, 553–558.
Uncertainty evaluation associated with fitting geometric surfaces to coordinate data
A. B. Forbes
Metrologia, 2006, 43(4), S282-S290.
Uncertainties in source distribution temperature and correlated colour temperature
J. L. Gardner
Metrologia, 2006, 43(5), 403-408.
Uncertainties of exposure-related quantities in mammographic x-ray unit quality control
K.J. Gregory, J.E. Pattison, G. Bibbo
Med. Phys., 2006, 33(3), 687-698.
Uncertainty calculation for calibrators and controls of laboratory diagnostic assays
A. Konnert, C. Berding and S. Arends
Clin. Chem. Lab. Med., 2006, 44(10), 1175-1182.
The evaluation of uncertainties in [UTC – UTC(k)]
W. Lewandowski, D. Matsakis, G. Panfilo, P. Tavella
Metrologia, 2006, 43(3), 278-286.
Determination of the uncertainties for ITS-90 realization by SPRTs between fixed points
C. W. Meyer and D.C. Ripple
Metrologia, 2006, 43(5), 327-340.
Impulse spectrum amplitude uncertainty analysis
N. G. Jr. Paulter and D. R. Larson
Metrologia, 2006, 43(6), 477-485.
Exhaust gas analysers and optimised sampling, uncertainties and costs
L. R. Pendrill and H. Källgren
Accred. Qual. Assur., 2006, 11(10), 496-505.
A simplified approach to the estimation of analytical measurement uncertainty
S. Populaire and E. Campos Giménez
Accred. Qual. Assur., 2006, 10, 485-493.
Uncertainty evaluation in non-contact aperture area measurements
A. Razet and J. Bastie
Metrologia, 2006, 43(5), 361-366.
A study of systematic biases and measurement uncertainties in ozone mole fraction measurements with the NIST Standard Reference Photometer
J. Viallon, P. Moussay, J. E. Norris, F. R. Guenther, R. I. Wielgosz
Metrologia, 2006, 43(5), 441-450.
Construction and uncertainty evaluation of a calibration system for GPS receivers
T. K. Yeh, C. S. Wang, C. W. Lee, Y. A. Liou
Metrologia, 2006, 43(5), 451-460.
2007
Uncertainties in the determination of particle size distributions using a mini tunnel–SMPS system during Diesel engine testing
O. Armas et al.
Meas. Sci. Technol., 2007, 18, 2121-2130.
Calibration of Thermocouples
Document EURAMET/cg-08/v.01 (previously EA-10/08), July 2007, EURAMET Calibration Guides.
Measurement and Generation of Small AC Voltages with Inductive Voltage Dividers
Document EURAMET/cg-09/v.01 (previously EA-10/09), July 2007, EURAMET Calibration Guides.
EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Document EURAMET/cg-11/v.01 (previously EA-10/11), July 2007, EURAMET Calibration Guides.
EA Guidelines on the Calibration of Temperature Block Calibrators
Document EURAMET/cg-13/v.01 (previously EA-10/13), July 2007, EURAMET Calibration Guides.
Bayesian estimate of the Newtonian constant of gravitation
V. Dose
Meas. Sci. Technol., 2007, 18, 176–182.
COMMENT: Comments on ‘Bayesian estimate of the Newtonian constant of gravitation’ with an alternative analysis
R. Willink
Meas. Sci. Technol., 2007, 18, 2275–2280.
REPLY: Reply to the comment on ‘Bayesian estimate of the Newtonian constant of gravitation’
V. Dose
Meas. Sci. Technol., 2007, 18, 2281–2282.
Some considerations related to the evaluation of measurement uncertainty for complex-valued quantities in radio frequency measurements
Hall B.D. [MSL]
Metrologia, 2007, 44(6), L62-L67.
Model-based measurement uncertainty estimation in amperometric dissolved oxygen concentration measurement
L. Jalukse et al.
Meas. Sci. Technol., 2007, 18, 1877-1886.
The uncertainty of UV–Vis spectrophotometric and FAAS analysis for the determination of iron in pharmaceutical products
J. Jürgens, L. Paama, I. Leito
Accred. Qual. Assur., 2007, 12(11), 593-601.
Uncertainty budget for the NIST electron counting capacitance standard, ECCS-1
Keller M.W., Zimmerman N.M., Eichenberger A.L. [NIST, METAS]
Metrologia, 2007, 44(6), 505-512.
Bivariate uncertainty analysis for impact testing
H. S. Kim et al.
Meas. Sci. Technol., 2007, 18, 3565-3571.
Evaluation of measurement uncertainty in the determination of jasmonic acid in Lemna minor L. by liquid chromatography with fluorescence detection
J. Kristl, B. Krajnčič, D. Brodnjak-Vončina and M. Veber
Accred. Qual. Assur., 2007, 12(6), 303-310.
An expression for the uncertainty in the water vapour pressure enhancement factor for moist air
Lovell-Smith J. [MSL]
Metrologia, 2007, 44(6), L49-L52.
An evaluation of the uncertainty associated with the measurement of the geomagnetic field with a D/I fluxgate theodolite
S. Marsal et al.
Meas. Sci. Technol., 2007, 18, 2143-2156.
Uncertainty associated with the energy content in flow measurement of natural gas including real-time correction for fluid properties
Martins L., Frota M.N., Lira I. [Petrobras Chile, PUC Arg., PUC Chile]
Metrologia, 2007, 44(5), 350-355.
Two procedures for the estimation of the uncertainty of spectral irradiance measurement for UV source calibration
A.-F. Obaton, J. Lebenberg, N. Fischer, S. Guimier, J. Dubard
Metrologia, 2007, 44(2), 152-160.
Quantitative determination of the uncertainty arising from the inhomogeneity of thermocouples
J. V. Pearce
Meas. Sci. Technol., 2007, 18, 3489-3495.
Uncertainty vade-mecum in radioactivity measurement
Ratel G. [BIPM]
Metrologia, 2007, 44(4), S102-S117.
Characterization of the measurement uncertainty of a laboratory EUV reflectometer for large optics
F. Scholze, T. Böttger, H. Enkisch, C. Laubis, L. van Loyen, F. Macco and S. Schädlich
Meas. Sci. Technol., 2007, 18, 126-130.
Uncertainty of the result of TOC determination in water samples
B. Tepuš, M. Simonič
Accred. Qual. Assur., 2007, 12(7), 357-364.
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
D.-H. Yu, M. Weiss, T. E. Parker
Metrologia, 2007, 44(1), 91-96.
2008
Setting up a decision rule from estimated uncertainty: emission limit value for PCDD and PCDF incineration plants in Wallonia, Belgium
B. Bergmans, F. Idczak, P. Maetz, J. Nicolas, S. Petitjean
Accred. Qual. Assur., 2008, 13, 639–644.
Simple uncertainty evaluation method for an interferometric flatness measurement machine using a calibrated test flat
Bitou Y., Takatsuji T., Ehara K. [NMIJ/AIST]
Metrologia, 2008, 45(1), 21-26.
Quantification of measurement uncertainty in the sequential determination of 210Pb and 210Po by liquid scintillation counting and alpha-particle spectrometry
Chang-Kyu Kim, P. Martin, A. Fajgelj
Accred. Qual. Assur., 2008, 13, 691–702.
Revisiting type-A uncertainties relating to the measurement of mass fraction of lead using isotope-dilution inductively coupled plasma mass spectrometry: a way of improving measurement precision and expanded uncertainty
J. Chung Wah Lam, Yiu Chung Yip, Wai Fong Tong
Accred. Qual. Assur., 2008, 13(6), 311-319.
Uncertainty of experimental integrals: application to the UV index calculation
Cordero R.R., Seckmeyer G., Pissulla D., Labbe F. [Leibniz Univ, ESPL Ecuador, UTFSM Valparaiso]
Metrologia, 2008, 45(1), 1-10.
Uncertainty of Gauge Block Calibration by Mechanical Comparison: A Worked Example for Like Materials
J. E. Decker, A. Ulrich, J. R. Pekelsky
NCSL International Measure, 2008, 3(4), 30.
Performance of uncertainty evaluation strategies in a food proficiency scheme
S. L. R. Ellison, K. Mathieson
Accred. Qual. Assur., 2008, 13(4-5), 231-238.
On “statistics and measurement results in chemistry”
S. L. R. Ellison, A. Williams
Eurachem Measurement Uncertainty and Traceability Working Group
Accred. Qual. Assur., 2008, 13(2), 111-112.
Uncertainty evaluation of the NRC imaging diffractometer
B. J. Eves et al.
Meas. Sci. Technol., 2008, 19, 075103 (10pp).
Approaches to uncertainty evaluation based on proficiency testing schemes in chemical measurements
P. Fisicaro, S. Amarouche, B. Lalere, G. Labarraque, M. Priel
Accred. Qual. Assur., 2008, 13(7), 361-366.
An improved matrix method for evaluating UTC offset uncertainties in the presence of link noises
Greenhall C.A. [Jet Propulsion Lab]
Metrologia, 2008, 45(1), 27-34.
On the uncertainties in effective dose estimates of adult CT head scans
K.J. Gregory, G. Bibbo, J.E. Pattison
Med. Phys., 2008, 35 (8), 3501-3510.
A GUM-compliant uncertainty budget for the analysis of total carbon dioxide (TCO2) in equine plasma
D. B. Hibbert, A. Stenhouse, C. Murphy, M. Jarrett, R. Osborne, J. H. Vine, L. Glowacki, C. Russo
Accred. Qual. Assur., 2008, 13(9), 523-530.
Compliance uncertainty of diameter characteristic in the next-generation geometrical product specifications and verification
W. L. Lu et al.
Meas. Sci. Technol., 2008, 19, 105103 (8pp).
Uncertainty propagation of atomic weight measurement results
Meija J., Mester Z. [INMS/NRC]
Metrologia, 2008, 45(1), 53-62.
Uncertainty of the concentration of a copper calibration solution
O. Mestek, K. Mališová, R. Koplík, J. Polák, M. Suchánek
Accred. Qual. Assur., 2008, 13(6), 305-310.
Uncertainties on distance and chromatic dispersion measurement using optical low-coherence reflectometry
Obaton A.-F., Quoix A., Dubard J. [LNE]
Metrologia, 2008, 45(1), 83-92.
A real-time assessment of measurement uncertainty in the experimental characterization of sprays
M R O Panão and A L N Moreira Meas. Sci. Technol., 2008, 19, 095402 (10pp).
Operating ‘cost’ characteristics in sampling by variable and attribute
L. R. Pendrill
Accred. Qual. Assur., 2008, 13, 619–63.
Uncertainties when using dual-wavelength or single-wavelength spectrophotometry to monitor the course of hexavalent chromium reduction mediated by zero-valent iron
M. Rivero-Huguet, W. D. Marshall
Accred. Qual. Assur., 2008, 13, 711–716.
The influence of positional uncertainty in free-field microphone calibration
Rodríguez Molares A., Sobreira Seoane M.A.,Pena Giménez A., Torres Guijarro S. [Univ. Vigo, LOM Ourense]
Metrologia, 2008, 45(2), 168-177.
Estimation of measurement uncertainty in organic analysis: two practical approaches
P. Shegunova, O. Bercaru, B. Sejerøe-Olsen
Accred. Qual. Assur., 2008, 13(1), 11-18.
Uncertainty estimation for coordinate metrology with effects of calibration and form deviation in strategy of measurement
K. Takamasu et al.
Meas. Sci. Technol., 2008, 19, 084001 (5pp).
Estimation of the efficiencies and uncertainties of the extraction and cleanup steps of pesticide residue determination in cucumber using 14C-carbaryl
O. Tiryaki, D. Baysoyu
Accred. Qual. Assur., 2008, 13(2), 91-99.
Measurement uncertainty in testing for antimicrobial activity on textile materials
E. Torlak
Accred. Qual. Assur., 2008, 13(10), 563-566.
Comparison of models for estimation of measurement uncertainties. Determination of BOD5 in wastewaters using a manometric method,
M. A. Trancoso, S. C. S. Calisto
Accred. Qual. Assur., 2008, 13(1), 19-28.
2009
Uncertainty assessment of effective radiating area and beam non-uniformity ratio of ultrasound transducers determined according to IEC 61689:2007
Alvarenga A.V., Costa-Félix R.P.B.[INMETRO]
Metrologia, 2009, 46, n°3, 367-374.
Evaluation of measurement uncertainties for the determination of total metal content in soils by atomic absorption spectrometry
S. Alves, M. M. Correia dos Santos, M. A. Trancoso
Accred. Qual. Assur., 2009, 14, 87–93.
Uncertainty and reproducibility in measuring the data acquisition system immunity to conducted disturbances
G Betta, D Capriglione, C Landi and N Pasquino
Meas. Sci. Technol., 2009, 20, 055105 (8pp).
On the uncertainty in the correction for the size-of-source effect
Bloembergen P.[NMIJ-AIST]
Metrologia, 2009, 46, n°5, 544-553.
Bayesian estimate of the zero-density frequency of a Cs fountain
Calonico D., Levi F., Lorini L., Mana G. [INRIM]
Metrologia, 2009, 46, n°6, 629-636.
Improved methods and uncertainty analysis in the calibration of the spring constant of an atomic force microscope cantilever using static experimental methods
C. A Clifford and M. P Seah
Meas. Sci. Technol., 2009, 20, 125501 (11pp).
Comparison of measurement uncertainties in direct plasma low-density lipoprotein cholesterol method of measurement and indirect estimation according to Friedewald equation
X. Fuentes-Arderiu et al.
Accred. Qual. Assur., 2009, 14, 179–183.
Evaluation of uncertainty in viscosity measurements by capillary master viscometers
Fujita Y., Kurano Y., Fujii K. [NMIJ/AIST]
Metrologia, 2009, 46, n°3, 237-248.
Uncertainties in effective dose estimates of adult CT head scans: The effect of head size
K.J. Gregory, G. Bibbo, J.E. Pattison
Med. Phys., 2009, 36(9), 4121-4125
An application of uncertain numbers in radio frequency power measurement
Hall B.D.[MSL]
Metrologia, 2009, 46, n°3, 351-358.
Modelling uncertainty in a concentration range
J. Jimenez-Chacon, M. Alvarez-Prieto
Accred. Qual. Assur., 2009, 14, 15–27.
Characteristics of precision 1 Ω standard resistors influencing transport behaviour and the uncertainty of key comparisons
G R Jones, B J Pritchard and R E Elmquist
Metrologia, 2009, 46, n°5, 503-511.
The propagation of uncertainty for humidity calculations
Lovell-Smith J.[MSL]
Metrologia, 2009, 46, n°6, 607-615.
Analysis and mitigation of measurement uncertainties in the traceability chain for the calibration of photovoltaic devices
H. Müllejans, W. Zaaiman and R. Galleano
Meas. Sci. Technol., 2009, 20, 075101 (12pp).
Uncertainty evaluation for linking a bilateral key comparison with the corresponding CIPM key comparison
Ojanen M., Shpak M., Kärhä P., Leecharoen R., Ikonen E.[TKK, NIMT, MIKES]
Metrologia, 2009, 46, n°5, 397-403.
Considerations with regard to the calculation of key comparison reference values and uncertainties
U. Panne and W. Bremser,
Accred. Qual. Assur.,2009, 14, 281–287.
Uncertainty budget for the temperature realization with a triple-fixed-point blackbody
M. Schalles
Accred. Qual. Assur.,2009, 14, 313–317.
Uncertainty estimation of nanoparticle size distribution from a finite number of data obtained by microscopic analysis
Song N.W., Park K.M., Lee I.-H., Huh H.[KRISS, GIST]
Metrologia, 2009, 46, n°5, 480-488.
Measurement uncertainty of shikimic acid in red wines produced in Chile
C. Tessini, C. Mardones, L. Rivas and D. von Baer,
Accred. Qual. Assur., 2009, 14, 381–387.
A review of statistical modelling and inference for electrical capacitance tomography
D Watzenig and C Fox
Meas. Sci. Technol., 2009, 20, 052002 (22pp).
2010
On-line dynamic error compensation of accelerometers by uncertainty-optimal filtering.
S. Eichstädt, A. Link, T. Bruns and C.Elster
Measurement, 2010, 43, 708-713.
Practical application of an analytical method for calculating a coverage interval
Paweł Fotowicz
Meas. Sci. Technol., 2010, 21, 087001 (7pp).
Uncertainty evaluation of the caesium fountain clock PTB-CSF2
Gerginov V., Nemitz N., Weyers S., Schröder R., Griebsch D., Wynands R.[PTB]
Metrologia, 2010, 47, n°1, 65-79.
The uncertainty associated with the weighted mean frequency of a phase-stabilized signal with white phase noise
Lee W.K., Yu D.H., Park C.Y., Mun J.[KRISS]
Metrologia, 2010, 47, n°1, 24-32.
A theoretical and experimental analysis of frequency transfer uncertainty, including frequency transfer into TAI.
Panfilo G., Parker T.E.[BIPM, NIST]
Metrologia, 2010, 47, n°5, 552-560.
Uncertainty evaluation for measurement of LED colour by Monte Carlo simulations.
Pousset N., Rougié B., Razet A.[LNE-INM]
Metrologia, 2009, 46, n°6, 704-718. Erratum: Metrologia, 2010, 47, n°1, 112.
Uncertainty in measurement for x-ray-computed tomography using calibrated work pieces
R. Schmitt and C. Niggemann
Meas. Sci. Technol., 2010, 21, 054008 (9pp).
On dead-time corrections for estimating rates
R. Willink
Meas. Sci. Technol., 2010, 21, 015101 (7pp).
Using the Monte Carlo approach to study effects of power measurement uncertainties on six-port reflectometer performance
J J Yao and S P Yeo
Meas. Sci. Technol., 2010, 21, 025103 (7pp).
2011
Hidden contributors to uncertainty and accuracy of results of residue analysis
Árpád Ambrus, Andrea Zentai, Judit Sali and István Ficzere,
Accred. Qual. Assur., 2011, 16, 3–11.
Evaluation of measurement uncertainty components associated with results of radiochemical neutron activation analysis for determination of uranium traces
Ljudmila Benedik and Urška Repinc
Accred. Qual. Assur., 2011, 16, 637–642.
Uncertainty due to parasitic accelerations in absolute gravimetry
Bich W., D'Agostino G., Pennecchi F., Germak A.[INRIM]
Metrologia, 2011, 48, n°3, 212-218.
Uncertainty evaluation for three-dimensional scanning electron microscope reconstructions based on the stereo-pair technique
L Carli, G Genta, A Cantatore, G Barbato, L De Chiffre and R Levi
Meas. Sci. Technol., 2011, 22, 035103 (11pp).
Evaluation of uncertainty in grating pitch measurement by optical diffraction using Monte Carlo methods
Jennifer E Decker, B J Eves, J R Pekelsky and R J Douglas
Meas. Sci. Technol., 2011, 22, 027001 (6pp).
Calibration of Gauge Block Comparators
Document EURAMET cg-2 (previously EA-10/02 and EAL-G21), version 2.0, 2011, European Association of National Metrology Institutes.
Calibration of Pressure Balances
Document EURAMET cg3, version 1.0, 2011, European Association of National Metrology Institutes.
Uncertainty of Force Measurements
Document EURAMET cg-4 (previously EA-10/04 and EAL-G22), version 2.0, 2011, European Association of National Metrology Institutes.
Extent of Calibration for Cylindrical Diameter Standards
Document EURAMET cg-6 (previously EA-10/06 and EAL-G29), version 2.0, 2011, European Association of National Metrology Institutes.
Measurement uncertainty evaluation and in-house method validation of the herbicide iodosulfuron-methyl-sodium in water samples by using HPLC analysis
Andreja Drolc and Albin Pintar,
Accred. Qual. Assur., 2011, 16, 21–29.
Uncertainty estimation in analysis of particulate-bound mercury in different size fractions of PM10 in ambient air
D. G. Gajghate, V. V. Khaparde, T. M. Pustode, P. P. Pipalatkar and C. V. Chalapati Rao,
Accred. Qual. Assur., 2011, 16, 459–465.
Measuring value correction and uncertainty analysis for homodyne interferometers
T Hausotte, B Percle, E Manske, R Füßl and G Jäger
Meas. Sci. Technol., 2011, 22, 094028 (6pp).
Analysis of the uncertainty in the measurement of electron densities in plasmas using the phase-resolved cutoff method.
Kim J.-K., Kwon J.-H., You S.-J., Seong D., Shin Y.-H.[KRISS, Korea Advanced Institute of Science and Technology]
Metrologia, 2011, 48, n°5, 306-310.
Uncertainty propagation through polynomial fitting and integration procedures with GUM and Monte Carlo applied to x-ray streak camera yield measurements.
Meyer C., Hubert S., André R., Cazaubon L., Lissayou C., Mangeant M., Prévot V., Ribolzi J. [CEA-DAM]
Metrologia, 2011, 48, n°1, 16-27.
Practical estimation of the uncertainty of analytical measurement standards
Ruud J. B. Peters, Ingrid J. W. Elbers, Mirjam D. Klijnstra and Alida A. M. Stolker,
Accred. Qual. Assur., 2011, 16, 567–574.
Evaluation of uncertainties in femtoampere current measurement for the number concentration standard of aerosol nanoparticles
Hiromu Sakurai and Kensei Ehara
Meas. Sci. Technol., 2011, 22, 024009 (11pp).
Uncertainty analysis of the diffusion rate in the dynamic generation of volatile organic compound mixtures
G Sassi, A Demichelis and M P Sassi
Meas. Sci. Technol., 2011, 22, 105104 (7pp).
2012
Uncertainty in measurements by counting
Bich W., Pennecchi F.[INRIM]
Metrologia, 2012, 49, n°1, 15-19.
Determination of Pitch Diameter of Parallel Thread Gauges by Mechanical Probing
Document EURAMET cg-10 (previously EA-10/10), version 2.1, 2012, European Association of National Metrology Institutes.
Efficient implementation of a Monte Carlo method for uncertainty evaluation in dynamic measurements.
S. Eichstädt, A. Link, P. Harris and C. Elster
Metrologia, 2012, 49, n°3, 401-410.
Uncertainty evaluation for traceable dynamic measurement of mechanical quantities: A case study in dynamic pressure calibration, in "Advanced Mathematical & Computational Tools in Metrology and Testing IX",
T. Esward, C. Matthews, S. Downes, A. Knott, S. Eichstädt and C. Elster
Series on Advances in Mathematics for Applied Sciences, 2012, vol. 84, eds. F. Pavese, M. Bär, J.-R. Filtz, A. B. Forbes, L. Pendrill, K. Shirono. World Scientific New Jersey.
Analysis of magnetic field fluctuation thermometry using Bayesian inference.
G. Wübbeler, F. Schmähling, J. Beyer, J. Engert and C. Elster
Meas. Sci. Technol., 2012, 23, 125004 (9pp).