Spirometry
Sleep diagnosis & therapy
Audiometry
www.sibelmed.com
“Close to you since1980”
añosyears
35
“Close to you since 1980”
“We are a team of more than 50 people. Since 1980 we have designed, manufactured and sold medical equipment for SPIROMETRY, AUDIOMETRY and SLEEP DIAGNOSIS & THERAPY.We adapt ourselves to the current demands of the market and healthcare professionals to contribute to the improvement of the sector.”
Sibelmed
Our identity
Our achievementsIn the health industry since 1980
More than 35 products designed
2 international patents
More than 55,000 medical devices sold
Participation in 26 research projects
Presence in more than 90 countries
Distribution network over 700 partners
6Models
3Models
spirometrydesktop spirometer
Primary Care · Occupational Health Primary Care · Occupational HealthRespiratory Units
Turbine transducerFVC, VC, MVV, BronchodilationSpirometry quality control programHospital and home modeOptional module SpO2W20s software included (C model)
EthernetBluetoothUSB HL7 Spain
HL7
DATOSPIR MICRO portable spirometer
BluetoothUSB HL7 Spain
HL7
SEPAR · ERS · KNUDSON · CRAPO · ZAPLETAL · MORRIS · AUSTRIA · GUTIERREZ · CASTRO-PEREIRA · POLGAR-WENG · HANKINSON-NHANES III · PEREZ–PADILLA · CRUZ-MORALES · GOLSHAN · GARCIA RIO · CANDELA · PLATINO ·THAI 2000
Disposable, turbine or fleisch transducerFVC, VC, MVV, Bronchodilation
Spirometry quality control programW20s software included
Internal printerSpO2, PIM-PEM, Sniff, internal battery (optional)
Electronic Weather Station*Bronchoconstriction* *Easy model optional
DATOSPIR TOUCH EASY DATOSPIR TOUCH DIAGNOSTIC DATOSPIR MICRO
DATOSPIR
GLI/QUANJER · SEPAR · ERS · KNUDSON · CRAPO · ZAPLETAL · MORRIS · AUSTRIA · GUTIERREZ · CASTRO-PEREIRA · POLGAR-WENG · HANKINSON-NHANES III PÉREZ–PADILLA · CRUZ-MORALES · GOLSHAN · GARCÍA RÍO · CANDELA · PLATINO · THAI 2000
W20s
Transducers fleisch, disposable and turbineTemperature sensor integratedAuto-shutdownW20s software included
More than 40 parametersFVC, VC, MVV, BronchodilationSpirometry quality controlQuanjer 2012-GLI with LLN and Z-score reference valuesManagement of different databasesCompatible with Windows XP, 7, 8.1 and 10.
3Models
computerized spirometer software
BluetoothUSB HL7 Spain
HL7
W20s + W20sLink
Interoperability compatible with CDA of spirometry
DATOSPIR
HL7link
HIS
Calibration Syringe Peak flow Mouthpieces, filters, paper...S-3000 Datospir PEAK-10 Consumable
It has the W20sLink optional module for the interoperability
with the HIS (HIS).
External ExG module for EEG, EMG, EOG, ECG tests (optional only for Sleep&GO)
sleep diagnosis & therapySAHS Screening cardiorespiratory polygraph
Turbine transducerFVC, VC, MVV, BronchodilationSpirometry quality control programHospital and home modeOptional module SpO2W20s software included (C model)
SomniLab
SOMNILAB
Positional device Software
Signals: Body position Actigraphy Stimulus intensityCompliance and trends reportCompatible with Windows XP, 7, 8.1 and 10
Reduces apnea and snoring indexIncreases blood oxygen saturationImproves high blood pressureImproves sleep quality and daytime sleepinessImproves quality of lifeImproves bed partner’s restSomniLab software includedSomnibel model for patient
More than 40 parametersFVC, VC, MVV, BronchodilationSpirometry quality controlQuanjer 2012-GLI with LLN and Z-score reference valuesManagement of different databasesCompatible with Windows XP, 7, 8.1 and 10.
software
Easy, user friendly operationColor graphics screen
Signals view in real time on screenOn-screen signal quality control
Programmable from a PC and the equipment itselfMicroSD memory cardSuitable for pediatrics
RESPIRATORY FLOW · SPO2 · PULSE (BPM) · SNORING · CHEST EFFORT · POSITION · ACTIVITY
ABDOMINAL EFFORT · THERMOCOUPLE · NIVEL CPAP · LIMB MOVEMENT · PULSE WAVE
De 1 to 8 channels (7 simultaneous) 8 to 16 channels (15 simultaneous)
BitmedLab
BITMEDLABScreen&Go Sleep&Go
Software
IAH severity graph Customizable automatic analysis Customizable viewComplete reportsTest exporting in ASCII and EDFIntegrated database Compatible with Windows XP, 7, 8.1 and 10
Bluetooth Micro SDMicro SD
audiometry
Compatible with all the audiometers of the market
W50 software
Speculum
6Models
5Models 10
Models
SCREENING DIAGNOSTIC CLINICAL
digital audiometer
audiometric test booth audiometric test booth audiometric test booth
SIBELSOUND 400
S-BASIC S-40 S-PREMIUM
USB
2 channelsAir conduction11 frequencies from 125 to 8000 HzContinuous and pulse tone
Great noise attenuation, 41 dBQuick and easy assemblyEconomical
2 channelsBone consuctionAir conductionMasking11 frequencies from 125 to 8000 HzContinuous and pulse tone
Great noise attenuation, 50 dBQuick and easy assemblyInterchangeable panelsDeluxe option 100% washableTailor-made projects
2 channelsBone consuctionAir conductionMasking11 frequencies from 125 to 8000 HzContinuous and pulse toneIntermediate frequenciesFrequency modulationSuprathreshold testsLogo-audiometrySoftware included
Great noise attenuation, 41 dBElegant and innovative designPatented mounting systemAssembly in less than 7 minutesWithout screwsSpecial measureCustomizable
It is compatible with all Sibelmed audiometers and
with the different versions of Windows XP, 7, 8.1 y 10.
SIBEL, S.A.U.Rosellón 500 bajos, 08026 BARCELONA (Spain)
Sales: Tel. +34 93 436 00 07 e-mail: [email protected] service. Tel. +34 93 433 54 50 e-mail: [email protected]
Fax: +34 93 436 16 11
www.sibelmed.com
BARCELONA
FG16
02_E
N -
Cat
álog
o G
ener
al -
V.1
.1 -
07/
2018