PRODUCE MORE. SPEND LESS. Energy Savings Using Variable Frequency Drives (VFDs) On Beam Pumps Bryan Lile, Texas Regional Manager
Transcript
Page 1: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Energy Savings UsingVariable Frequency Drives (VFDs)On Beam PumpsBryan Lile, Texas Regional Manager

Page 2: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

SPOC Automation: Who Are We?

• Oil and Gas • Leader in Oilfield Variable Speed Drives• Specialists in Optimizing Pump Control

with 200+ years of experience• 15+ Years in business• Family Owned• Based in Trussville, AL

Page 3: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Energy Savings Using a VFD

• VFD has Power Factor up to .97, eliminating penalties

Page 4: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Energy Savings Using a VFD•Power Factor up to .97 eliminates penalties

•Can use NEMA B motors to save 3-5% additional energy

Page 5: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Energy Savings Using a VFD

•Power Factor up to .97 eliminates penalties

•Can use NEMA B motors to save 3-5% additional energy

•VFDs eliminate regeneration

Page 6: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Energy Savings Using a VFD• VFD can eliminate regeneration

• When the heavier side of an unbalanced beam is moving up, the motor uses power

• When the heavier side of an unbalanced beam is moving down, the motor becomes a generator

• The generator sends power back into the electric grid

• The utility does not give credit for this generated “negative” power

Page 7: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Eliminating Wasted Energy in Regeneration

• Most Beam Pump VFDs use Dynamic Braking to deal with regeneration.

• Brake Resistors increase energy consumption 15-30%

• Iron Horse drives do not require resistors

Page 8: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Eliminating Wasted Energy in Regeneration

• The area in the green is typical lost as heat in a VFD with a brake resistor

• The area in the green is given back to the utility with a starter panel

Wasted Energy

Page 9: SPOC Automation Energy Savings Presentation DUG Eagleford

PRODUCE MORE. SPEND LESS.

Eliminating Wasted Energy in Regeneration

• Recent Well Test by SPOC Automation with Laredo Energy in Odessa, 7.1 SPM, 50HP motor

• With starter: 9.7KW of energy

• With VFD: 7.3KW of energy

25% reduction in energy cost$4000 per year savings