Spot Coolers
SUPERIOR
PORTABLE
COOLING
AND
HEATING
Portable Air Conditioning and Heating
144577 Spot Coolers Reference Guide 2014.indd 1 5/21/14 12:11 PM
Trust Your Portable Cooling
and Heating Needs
to Spot Coolers...
We opened the doors of Spot Coolers in 1985 brimming with ideas and energy. Since then we’ve focused our efforts on developing portable cooling and heating products to serve industry, business, manufacturing, education and health care.
We brought high quality, cost-effective portable cooling to the marketplace and we continue to develop new products to meet demanding conditions and specific needs. Our mission is to find the best temperature control solutions for a constantly changing world.
With our help you'll never have to worry about excessive heat creating problems for your people, your products or your business. Our goal is achieve absolute customer satisfaction.
With plenty of hard work and the help of many motivated, capable people working together.
People are, and will always be, the backbone of our organization. Knowledgeable, skilled and focused on your satisfaction, they will help you find what you need whether its portable heating or cooling. Finding the right solution to your particular need is our goal.
Whether you face a critical hospital emergency, a server room meltdown or an over-heated production line - trust the team at Spot Coolers to be there for you when you need us!
How do we earn your business?
Cool People! Cool Service! Cool Products!
144577 Spot Coolers Reference Guide 2014.indd 2 5/21/14 12:12 PM
How do we earn your business?
Cool People! Cool Service! Cool Products!
Don’t Put the Safety and Security of Your Facility at Risk...
MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation.
We know the value of peace of mind... and we ensure
that your facility and staff are safe and secure.
You can trust that Spot Coolers personnel
are trained, qualified and reliable!
...Spot Coolers is the Source for Immediate,
Dependable, Emergency Service!
• All portable cooling companies aren’t alike... As a member of a Fortune 50 company Spot Coolers holds
the highest standards for business ethics, safety and security.
We comply with OSHA and all federal and state regulations to
ensure customer, employee, and community well-being.
• Trust our reputation...it speaks for itself! When you partner with Spot Coolers you enjoy peace of mind
knowing that all of our people are experienced, knowledgeable
and carefully screened. Our reputation is built on the
consistency of our performance.
• Excellent equipment, excellent service... Whether you rent or buy, Spot Coolers offers units from
1-12 tons available whenever you need them. We can service
your facilities from one of our 37 locations nationwide.
Our commitment is absolute.
We take the risk out of renting or buying
Why use anybody else?
144577 Spot Coolers Reference Guide 2014.indd 3 5/21/14 12:12 PM
Office Pro, Classic and Classic Plus
THE OFFICE PRO
For indoor environments such as computer and telecom
rooms or offices that contain heat-generating electronics,
use our Office Pro Portable Air Conditioner Series.
This line of self-contained, portable units from 12,000
to 60,000 Btu/hr is simple to install: just roll it in, plug
it in, and turn it on for instant spot cooling.
The Office Pro’s programmable digital controls make it
perfect for automatic after-hours and weekend operations.
THE CLASSIC and CLASSIC PLUS
For versatility within offices or factories, use our original
line of MovinCool units in the Classic Portable Air
Conditioner Series. Ranging in sizes from 10,000
to 60,000 Btu/hr, there’s a size to meet any requirement
or application. If you need more precise temperature
control, the Classic Plus Series of portable cooling units
offers the same benefits as the Classic Series, plus
digital temperature controls.
The Classic and Classic Plus portable air conditioners
are designed to work in the hottest environments
such as production lines, manufacturing processes,
injection molding, and metal forming. They require
little or no installation, allowing for immediate cooling
when and where it’s needed.
144577 Spot Coolers Reference Guide 2014.indd 4 5/21/14 12:12 PM
Office Pro, Classic and Classic Plus
Ceiling Mounted Cooling
The Newest, Award-Winning Product from
MOVINCOOL
The CM Series
The CM series are ceiling-mounted
packaged air conditioners.
Featuring the shortest top-to-bottom
profile in the industry, the CM series
fits into virtually any drop ceiling,
making it the perfect cooling solution
for any room with limited floor space.
MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation
CM 12• 10,500 Btu/h at 80ºF 50% RH (Evaporator) 95ºF 40% RH (Condenser)• 7,000 Btu/h at 72ºF 50% RH• 115V, 15 amps – no special electric required• No floor space needed• Can fit into tight ceiling spaces
CM 25• 25,000 Btu/h at 80ºF 50% RH (Evaporator) 95ºF 40% RH (Condenser)• 18,900 Btu/h at 72ºF 50% RH• 208/230V, 20 amps • No floor space needed• Can fit into tight ceiling spaces
CMW 30• 29,400 Btu/h at 80ºF 50% RH (Evaporator) 95ºF 40% RH (Condenser)• 22,000 Btu/h at 72ºF 50% RH• 208/230V, 20 amps • No floor space needed• Can fit into tight ceiling spaces
KEY FEATURES
Inverter Compressor*Warning Signals & Audible Alarms for Condensation Overflow
Built-in Flanges
Detachable Flanges Enable Easy Installation**
Wide Operating RangeVibration Isolator Included*
Inverter Fan Motors*
*CM25 & CMW30 only**CM25 only
Built-in Mounting Brackets Designed for Off-the-Shelf Hardware
Connects toBuilding ControlSystem
Wall Mount Controller
144577 Spot Coolers Reference Guide 2014.indd 5 5/21/14 12:12 PM
The Heat Pump Series
COOLING MODE
room air
hot air exhaust
room air
cool air output
HEAT MODE
room air
cool air exhaust
room air
warm air output
APPLICATIONS/USES
• Supplemental heat for spaces where the system is inadequate -cold or drafty offices, lobbies, warehouses, school rooms, daycare centers, retail spaces, nursing homes - any place where additional heat is needed.
• Spot heating of an office or facility when the main heating system is being serviced - a necessity for facility management companies, multi-unit facilities, hospitals, schools and universities.
• Heating of trouble spots in buildings where duct work cannot be installed. (Many of these same spaces will require cooling during the summer months).
FEATURES
• E lectronic Control - Automatic temperature control with adjustable fan speeds. HEAT/COOL/AUTO selection with automatic change-over and fan speed control
• H ot Gas Bypass Valve - allows heat pump operation in cool temperatures without coil freeze-up
• E lectrostatic Air Filter for both the evaporator and condenser air
ACCESSORIES
• Du ct Kit - For discharging condenser air above a drop ceiling
• N ozzle Kit - Dual nozzles direct the air to an intended target
• Di scharge Duct Adapter - Allows for supply air to be ducted through a round duct
• Re turn Air Plenum - Plenum that allows for a round duct to be used to return room air to the unit
• C ondenser Plenum - Plenum that allows for round duct to be used to return air to the condenser
The Oceanaire Heat Pump Series is designed to provide comfort to any space during cooling and heating seasons. In most applications, heat pumps generate more heat than comparable electric heaters with the same power.
The electronic controller can be set to heat, cool or automatically moderate the space temperature and air flow.
The heat pump is a portable heating and cooling unit, that can provide year-round comfort in almost any application.
144577 Spot Coolers Reference Guide 2014.indd 6 5/21/14 12:12 PM
APPLICATIONS/USES
• Supplemental heat for spaces where the system is inadequate -cold or drafty offices, lobbies, warehouses, school rooms, daycare centers, retail spaces, nursing homes - any place where additional heat is needed.
• Spot heating of an office or facility when the main heating system is being serviced - a necessity for facility management companies, multi-unit facilities, hospitals, schools and universities.
• Heating of trouble spots in buildings where duct work cannot be installed. (Many of these same spaces will require cooling during the summer months).
FEATURES
• Electronic Control - Automatic temperature control with adjustable fan speeds. HEAT/COOL/AUTO selection with automatic change-over and fan speed control
• Hot Gas Bypass Valve - allows heat pump operation in cool temperatures without coil freeze-up
• Electrostatic Air Filter for both the evaporator and condenser air
ACCESSORIES
• Duct Kit - For discharging condenser air above a drop ceiling
• Nozzle Kit - Dual nozzles direct the air to an intended target
• Discharge Duct Adapter - Allows for supply air to be ducted through a round duct
• Return Air Plenum - Plenum that allows for a round duct to be used to return room air to the unit
• Condenser Plenum - Plenum that allows for round duct to be used to return air to the condenser
The Oceanaire Heat Pump Series is designed to provide comfort to any space during cooling and heating seasons. In most applications, heat pumps generate more heat than comparable electric heaters with the same power.
The electronic controller can be set to heat, cool or automatically moderate the space temperature and air flow.
The heat pump is a portable heating and cooling unit, that can provide year-round comfort in almost any application.
Water-Cooled Cooling
OWC
DISCHARGEDUCTADAPTER
NOZZLEKIT
RETURN AIRPLENUM
HOSE KIT
DELUXE ELECTRONICCONTROL
ELECTROSTATICFILTER
water source connection
water in
water out
condensate drain
Water-cooled portables are a very efficient source of cooling that allows you to cool areas where air-cooled equipment will not. By using municipal water, the water-cooled portables provide air conditioning to out-of-the-way building areas where condenser air is not available, such as electrical rooms, laboratories, and small offices. An added benefit: the OWC will cool a space without exchanging air in surrounding areas. This feature makes the unit a preferred choice for medical locations such as surgical suites and confinement areas. The OWC is a self-contained air conditioner, equipped with a regulating valve (for water usage control), a condensate pump, high pressure reset (for loss of water) and a deluxe electronic control system. Roll it in, hook it up with the optional hose kit and begin cooling.
FEATURES
Condensate Pump - automatically removes condensate while cooling
High Pressure Cut-out - shuts down the unit if water supply is interrupted
Electrostatic Air Filter for both the evaporator and condenser air
Electronic Control - automatic temperature control with adjustable fan speeds. Cooling display can be remote mounted
Water Regulating Valve - regulates condenser water flow, and cuts off water when the compressor is OFF
Hose Kits - for connecting to water source and for draining the unit
ACCESSORIES
Hose Kit - for connecting the OWC unit, hose kits are available in 10, 25 and 40 foot lengths
Nozzle Kit - dual nozzles direct the cool air to an intended target
Discharge Duct Adapter - allows for the OWC supply to be ducted through a round duct
Return Air Plenum - plenums that allow for a round duct to be returned to the OWC unit
144577 Spot Coolers Reference Guide 2014.indd 7 5/21/14 12:12 PM
Spot Coolers Rents And Sells Severe-Duty Cart-Mounted Units In 5 & 12 Ton Capacities
Large Capacity, Trailer-Mounted Cooling
No standard equipment provides "one size fits all" performance. Our cart mounted series was designed for those applications where standard equipment isn't appropriate.
These compact portables provide the solution when large capacity cooling is required indoors or outdoors. Small enough to wheel inside office buildings and other institutional spaces, our cart mounted series is ideal for short or long term cooling requirements. Light and compact, they provide big capacity. They provide the needed interim cooling in computer and equipment rooms when dedicated A/C units must be shut down for repair or service.
On construction sites or during maintenance intervals, these rugged units provide continous and reliable operation outdoors in any weather. Powerful blowers support long duct runs to direct cool air where it's needed. Special built-in features allow for continous operation even when ambient temperatures are extreme.
Heavy Duty Cooling To Go!
144577 Spot Coolers Reference Guide 2014.indd 8 5/21/14 12:12 PM
800.367.8675 www.spot-coolers.com
Spot Coolers Is Your Resource For Custom Designed Solutions
To Tough Cooling Problems
Standard portable air conditioning equipment was designed for interior use. But some situations require heavy duty equipment that functions in extreme conditions. That’s why Spot Coolers created its Transportable Temperature Systems custom build division. Transportable Temperature System's model line of compact cart and trailer mounted equipment is built to industrial grade standards. All TTS equipment is rugged, designed to function seamlessly, regardless of weather conditions. These custom-built units will run continuously, indoors or outdoors providing years of reliable operation.
When “off-the-shelf equipment” won't cut it, you need a solution specifically designed to meet your needs; something that out-performs everything else. In those situations, we offer turn-key design, production, and fabrication capabilities. Whether you need compact design, higher static capability, low ambient operation, or a specific configuration, Transportable Temperature Systems can build equipment to meet any exacting specifications.
Custom Cooling Design
Talk To Us... We're Listening!
144577 Spot Coolers Reference Guide 2014.indd 9 5/21/14 12:12 PM
Portable Air Cooled Air Conditioners
All specifications subject to change without notice. Standard warranty includes 12 months on entire unit and 36 months on the compressor. Call for details on Spot Cooler’s new Extended Warranty Program. All models feature compressor overload relay and fan
motor protection. All models also feature compressor short-cycle protection, return air thermostat, automatic restart and accommodate a condensate pump kit. All models are 50 Hertz (Hz) compatible with a slight performance decrease from specifications listed above.
MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation.
SPECIFICATIONS OFFICE PRO 12
OFFICE PRO 18
OFFICE PRO 24
OFFICE PRO 36
OFFICE PRO 60
OFFICE PRO63
Cooling Capacity (95ºat 60% RH) (Btu/Hr)
1 Ton 12,000
1.5 Ton 16,800
2 Ton 24,000
3 Ton 36,000
5 Ton 60,000
5 Ton 60,000
Electronic Features (Control Panel/Thermostat Control) Programmable Programmable Programmable Programmable Programmable Programmable
Air Flow Evaporator (CFM, High/Low) 410/380 540/500 630/545 990/825 1940/1770 1940/1770
Air Flow Condenser (CFM, High/Low) 820/715 770/710 870/760 1490/1060 2830/2650 2830/2650
Operating Conditions (Min-Max)(at 50% RH) 65º-95ºF 65º-95ºF 65º-95ºF 65º-95ºF 65º-105ºF 65º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/1 460/3
Min-Max Voltage 105-125 105-125 198-250 198-250 198-250 440/480
Power Consumption (KW) 1.3 1.7 2.9 4.3 6.6 6.6
Current Consumption (AMPS) 11.9 15.6 13.2 19.6 29 9.5
Circuit Breaker Size (AMPS) 15 20 20 30 50 20
NEMA Plug Configuration 5-15 5-20 6-20 6-30 6-50 L16-20
Power Cord (Gauge/Length) 14 AWG (3-core)/10 ft
12 AWG(3-core)/10 ft
12 AWG (3-core)/6 ft
12 AWG (3-core)/6 ft
6 AWG (3-core)/6 ft
12AWG(4core)/6 ft
Dimensions W x D x H (IN) 21 x 27 x 44 21 x 27 x 44 21 x 27 x 49 30 x 44 x 52 30 x 52 x 65 30 x 52 x 65
Weight (Net Weight/Shipping Weight) (LBS) 151/182 170/201 216/253 432/509 623/753 705/835
Humidity Removed at 60% RH (GAL/HR) 0.58 0.96 1.25 2.17 3.04 3.04
Drain Tank Capacity (GAL) 5 5 5 2 @ 2.5 gal Auto Pump Auto Pump
Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A
Sound Level w/Duct (db(A), High/Low) 52/50 61/59 63/61 65/62 69/67 69/67
Max. Duct Length (Cold Duct Hose/Hot Duct Hose) 30 ft/60 ft 25 ft/100 ft 50 ft/45 ft 40 ft/60 ft 40 ft/100 ft 40 ft/100ft
FIELD-INSTALLED ACCESSORIES
Hot Duct Flange INCLUDED 12" INCLUDED 12" INCLUDED 12" INCLUDED 16" INCLUDED 16" INCLUDED 16"
2 x 2 Ceiling Tile w/Hose CT-12 CT-12 CT-12 CT-16 CT-16 CT-16
Condenser Return Air Plenum DAP DAP DAP DAP DAP DAP
Condensate Pump 115 volt 115 volt 230 volt 230 volt INCLUDED INCLUDED
www.spot-coolers.com
CLASSIC PLUS 14
CLASSIC PLUS 26
CLASSIC 10
CLASSIC 40
CLASSIC 60
1 Ton 13,200
2 Ton 24,000
1 Ton 10,000
3.25 Ton 39,000
5 Ton 60,000
Programmable Programmable Digital Digital Digital
440/380 708/600 265 1060 1580
880/760 1680/1190 740 2650 3800
70º-113ºF 70º-113ºF 70º-105ºF 75º-115ºF 75º-115ºF
115/1 208-230/1 115/1 220/3 460/3
105-125 198-250 105-125 198-250 440-480
1.3 204 1.1 4.2 5.9
11.9 10.8 10 14 8.8
15 20 15 25 20
5-15 6-20 5-15 L15-30 N/A
14 AWG(3-core)/10 ft
12 AWG(3-core)/6 ft
14 AWG (3-core)/10 ft
12 AWG (4-core)/6 ft N/A
19 x 26 x 41 19 x 29 x 47 19 x 26 x 41 26 x 43 x 38 32 x 49 x 42
166/197 199/270 156/194 344/396 474/566
0.67 1.38 0.63 2.5 3.84
5 5 5 2@ 5 gal (optional) N/A
R-410A R-410A R-410A R-410A R-410A
57/55 66/64 55 72 w/o duct 72 w/o duct
30 ft/60 ft 60 ft/45 ft 40 ft/60 ft Varies/40 ft Varies /40 ft
12" 12" 12" INCLUDED INCLUDED
CT-12 CT-12 CT-12 N/A N/A
MAP MAP MAP N/A N/A
115 volt 230 volt 115 volt N/A N/A
* CLASSIC 40 and CLASSIC 60 units not optimum for office or computer room use
144577 Spot Coolers Reference Guide 2014.indd 10 5/21/14 12:12 PM
All specifications subject to change without notice. Standard warranty includes 12 months on entire unit and 36 months on the compressor. Call for details on Spot Cooler’s new Extended Warranty Program. All models feature compressor overload relay and fan
motor protection. All models also feature compressor short-cycle protection, return air thermostat, automatic restart and accommodate a condensate pump kit. All models are 50 Hertz (Hz) compatible with a slight performance decrease from specifications listed above.
MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation.
SPECIFICATIONS OFFICE PRO 12
OFFICE PRO 18
OFFICE PRO 24
OFFICE PRO 36
OFFICE PRO 60
OFFICE PRO63
Cooling Capacity (95ºat 60% RH) (Btu/Hr)
1 Ton 12,000
1.5 Ton 16,800
2 Ton 24,000
3 Ton 36,000
5 Ton 60,000
5 Ton 60,000
Electronic Features (Control Panel/Thermostat Control) Programmable Programmable Programmable Programmable Programmable Programmable
Air Flow Evaporator (CFM, High/Low) 410/380 540/500 630/545 990/825 1940/1770 1940/1770
Air Flow Condenser (CFM, High/Low) 820/715 770/710 870/760 1490/1060 2830/2650 2830/2650
Operating Conditions (Min-Max)(at 50% RH) 65º-95ºF 65º-95ºF 65º-95ºF 65º-95ºF 65º-105ºF 65º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/1 460/3
Min-Max Voltage 105-125 105-125 198-250 198-250 198-250 440/480
Power Consumption (KW) 1.3 1.7 2.9 4.3 6.6 6.6
Current Consumption (AMPS) 11.9 15.6 13.2 19.6 29 9.5
Circuit Breaker Size (AMPS) 15 20 20 30 50 20
NEMA Plug Configuration 5-15 5-20 6-20 6-30 6-50 L16-20
Power Cord (Gauge/Length) 14 AWG (3-core)/10 ft
12 AWG(3-core)/10 ft
12 AWG (3-core)/6 ft
12 AWG (3-core)/6 ft
6 AWG (3-core)/6 ft
12AWG(4core)/6 ft
Dimensions W x D x H (IN) 21 x 27 x 44 21 x 27 x 44 21 x 27 x 49 30 x 44 x 52 30 x 52 x 65 30 x 52 x 65
Weight (Net Weight/Shipping Weight) (LBS) 151/182 170/201 216/253 432/509 623/753 705/835
Humidity Removed at 60% RH (GAL/HR) 0.58 0.96 1.25 2.17 3.04 3.04
Drain Tank Capacity (GAL) 5 5 5 2 @ 2.5 gal Auto Pump Auto Pump
Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A
Sound Level w/Duct (db(A), High/Low) 52/50 61/59 63/61 65/62 69/67 69/67
Max. Duct Length (Cold Duct Hose/Hot Duct Hose) 30 ft/60 ft 25 ft/100 ft 50 ft/45 ft 40 ft/60 ft 40 ft/100 ft 40 ft/100ft
FIELD-INSTALLED ACCESSORIES
Hot Duct Flange INCLUDED 12" INCLUDED 12" INCLUDED 12" INCLUDED 16" INCLUDED 16" INCLUDED 16"
2 x 2 Ceiling Tile w/Hose CT-12 CT-12 CT-12 CT-16 CT-16 CT-16
Condenser Return Air Plenum DAP DAP DAP DAP DAP DAP
Condensate Pump 115 volt 115 volt 230 volt 230 volt INCLUDED INCLUDED
Portable Air Cooled Air Conditioners
www.spot-coolers.com
CLASSIC PLUS 14
CLASSIC PLUS 26
CLASSIC 10
CLASSIC 40
CLASSIC 60
1 Ton 13,200
2 Ton 24,000
1 Ton 10,000
3.25 Ton 39,000
5 Ton 60,000
Programmable Programmable Digital Digital Digital
440/380 708/600 265 1060 1580
880/760 1680/1190 740 2650 3800
70º-113ºF 70º-113ºF 70º-105ºF 75º-115ºF 75º-115ºF
115/1 208-230/1 115/1 220/3 460/3
105-125 198-250 105-125 198-250 440-480
1.3 204 1.1 4.2 5.9
11.9 10.8 10 14 8.8
15 20 15 25 20
5-15 6-20 5-15 L15-30 N/A
14 AWG(3-core)/10 ft
12 AWG(3-core)/6 ft
14 AWG (3-core)/10 ft
12 AWG (4-core)/6 ft N/A
19 x 26 x 41 19 x 29 x 47 19 x 26 x 41 26 x 43 x 38 32 x 49 x 42
166/197 199/270 156/194 344/396 474/566
0.67 1.38 0.63 2.5 3.84
5 5 5 2@ 5 gal (optional) N/A
R-410A R-410A R-410A R-410A R-410A
57/55 66/64 55 72 w/o duct 72 w/o duct
30 ft/60 ft 60 ft/45 ft 40 ft/60 ft Varies/40 ft Varies /40 ft
12" 12" 12" INCLUDED INCLUDED
CT-12 CT-12 CT-12 N/A N/A
MAP MAP MAP N/A N/A
115 volt 230 volt 115 volt N/A N/A
* CLASSIC 40 and CLASSIC 60 units not optimum for office or computer room use
144577 Spot Coolers Reference Guide 2014.indd 11 5/21/14 12:12 PM
Low Temperature Portable Air Cooled Air Conditioners
SPECIFICATIONS 2OAC 1211
2OAC 1811
2OAC 2412
2OAC 3612
2OAC 3632
2OAC 3634
2OAC 6012
2OAC 6032
2OAC 6034
Cooling Capacity (Btu/Hr)@ ARI 80ºF – 67º at 52% relative humidity
1 Ton 11,800
1.5 Ton/ 16,800
2 Ton/ 24,020
3 Ton/ 36,050
3 Ton/ 36,050
3 Ton/ 36,050
5 Ton/ 60,050
5 Ton/ 60,050
5 Ton/ 60,050
Electronic Features Control Panel/Thermostat Control
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Air Flow Condenser (CFM) 580 930 1010 1390 1390 1390 2200 2200 2200
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 10.4 14.1 14.9 18.1 17.2 8.7 32.0 20.4 14.8
NEMA Plug Configuration 5-15P 5-20P 6-20P 6-30P L15-30P L16-20P 6-50P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
12/3 10 ft
10/4 10 ft
10/4 10 ft
8/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 25 x 37 24 x 30 x 46 24 x 30 x 46 28 x 35 x 51 28 x 35 x 51 28 x 35 x 51 28 x 39 x 53 28 x 39 x 53 28 x 39 x 53
Weight (LBS) 180 260 260 365 365 380 485 485 515
Humidity Removedat 60%RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
Drain Tank Capacity (GAL) 5 5 5 5 5 5 Auto Pump Auto Pump Auto Pump
410A Charge (OZ) 18 40 37 66 66 66 80 80 80
Sound Level w/Duct (dB(A)) 54 60 65 69 69 69 78 78 78
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-1 AC-2 AC-2 AC-6 AC-6 AC-6 AC-6 AC-6 AC-6
Heresite Coated Coils HC-1 HC-2 HC-2 HC-6 HC-6 HC-6 HC-6 HC-6 HC-6
FIELD-INSTALLED ACCESSORIES
Nozzle Kit 2NK-1 2NK-2 2NK-2 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3
Ceiling Kit 2 x 2 CK-12 CK-12 CK-12 CK-16 CK-16 CK-16 CK-16 CK-16 CK-16
Cond. Return Air Plenum 2DCP-1 2DCP-2 2DCP-2 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5
Evap. Return Air Plenum DEP-10 2DEP-12 2DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Condensate Pump 2DPC-1 2DPC-1 2DPC-2 2DPC-2 2DPC-2 2DPC-2 STD STD STD
Duct Adapter 2DDA-6 2DDA-10 2DDA-10 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16
SPECIFICATIONS 2OACH 1211
2OACH 1811
2OACH 2412
2OACH 3612
2OACH 3632
2OACH 3634
2OACH 6012
2OACH 6032
2OACH 6034
Cooling Capacity (Btu/Hr) @ARI 80º - 67º at 52% relative humidity
1 Ton/ 11,800
1.5 Ton/ 16,800
2 Ton/ 24,020
3 Ton/ 36,050
3 Ton/ 36,050
3 Ton/ 36,050
5 Ton/ 60,050
5 Ton/ 60,050
5 Ton/ 60,050
Heating Capacity (Btu/Hr)@ ARI 70ºF – 60º at 60% relative humidity
11,000 15,600 24,020 32,500 32,500 32,500 53,500 53,500 53,500
Electronic Features(Control Panel/Thermostat Control)
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Air Flow Condenser (CFM) 580 930 1010 1390 1390 1390 2200 2200 2200
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 10.4 14.1 14.9 18.1 17.2 8.7 32.0 20.4 14.8
NEMA Plug Configuration 5-15P 5-20P 6-20P 6-30P L15-30P L16-20P 6-50P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
12/3 10 ft
10/4 10 ft
10/4 10 ft
8/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 25 x 37 24 x 30 x 46 24 x 30 x 46 28 x 35 x 51 28 x 35 x 51 28 x 35 x 51 28 x 39 x 53 28 x 39 x 53 28 x 39 x 53
Weight (LBS) 180 260 260 365 365 380 485 485 515
Humidity Removedat 60% RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
Drain Tank Capacity (GAL) 5 5 5 5 5 5 Auto Pump Auto Pump Auto Pump
410A Charge (OZ) 18 40 37 66 66 66 80 80 80
Sound Level w/Duct (dB(A)) 54 60 65 69 69 69 78 78 78
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-1 AC-2 AC-2 AC-6 AC-6 AC-6 AC-6 AC-6 AC-6
Heresite Coated Coils HC-1 HC-2 HC-2 HC-6 HC-6 HC-6 HC-6 HC-6 HC-6
FIELD-INSTALLED ACCESSORIES
Nozzle Kit 2NK-1 2NK-2 2NK-2 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3
Ceiling Kit 2 x 2 CK-12 CK-12 CK-12 CK-16 CK-16 CK-16 CK-16 CK-16 CK-16
Cond. Return Air Plenum 2DCP-1 2DCP-2 2DCP-2 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5
Evap. Return Air Plenum DEP-10 2DEP-12 2DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Condensate Pump 2DPC-1 2DPC-1 2DPC-2 2DPC-2 2DPC-2 2DPC-2 STD STD STD
Duct Adapter 2DDA-6 2DDA-10 2DDA-10 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16
144577 Spot Coolers Reference Guide 2014.indd 12 5/21/14 12:12 PM
Low Temperature Portable Air Cooled Air Conditioners
SPECIFICATIONS 2OAC 1211
2OAC 1811
2OAC 2412
2OAC 3612
2OAC 3632
2OAC 3634
2OAC 6012
2OAC 6032
2OAC 6034
Cooling Capacity (Btu/Hr)@ ARI 80ºF – 67º at 52% relative humidity
1 Ton 11,800
1.5 Ton/ 16,800
2 Ton/ 24,020
3 Ton/ 36,050
3 Ton/ 36,050
3 Ton/ 36,050
5 Ton/ 60,050
5 Ton/ 60,050
5 Ton/ 60,050
Electronic Features Control Panel/Thermostat Control
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Air Flow Condenser (CFM) 580 930 1010 1390 1390 1390 2200 2200 2200
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 10.4 14.1 14.9 18.1 17.2 8.7 32.0 20.4 14.8
NEMA Plug Configuration 5-15P 5-20P 6-20P 6-30P L15-30P L16-20P 6-50P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
12/3 10 ft
10/4 10 ft
10/4 10 ft
8/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 25 x 37 24 x 30 x 46 24 x 30 x 46 28 x 35 x 51 28 x 35 x 51 28 x 35 x 51 28 x 39 x 53 28 x 39 x 53 28 x 39 x 53
Weight (LBS) 180 260 260 365 365 380 485 485 515
Humidity Removedat 60%RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
Drain Tank Capacity (GAL) 5 5 5 5 5 5 Auto Pump Auto Pump Auto Pump
410A Charge (OZ) 18 40 37 66 66 66 80 80 80
Sound Level w/Duct (dB(A)) 54 60 65 69 69 69 78 78 78
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-1 AC-2 AC-2 AC-6 AC-6 AC-6 AC-6 AC-6 AC-6
Heresite Coated Coils HC-1 HC-2 HC-2 HC-6 HC-6 HC-6 HC-6 HC-6 HC-6
FIELD-INSTALLED ACCESSORIES
Nozzle Kit 2NK-1 2NK-2 2NK-2 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3
Ceiling Kit 2 x 2 CK-12 CK-12 CK-12 CK-16 CK-16 CK-16 CK-16 CK-16 CK-16
Cond. Return Air Plenum 2DCP-1 2DCP-2 2DCP-2 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5
Evap. Return Air Plenum DEP-10 2DEP-12 2DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Condensate Pump 2DPC-1 2DPC-1 2DPC-2 2DPC-2 2DPC-2 2DPC-2 STD STD STD
Duct Adapter 2DDA-6 2DDA-10 2DDA-10 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16
Portable Heat Pump Air Conditioners
800.367.8675 www.spot-coolers.com
SPECIFICATIONS 2OACH 1211
2OACH 1811
2OACH 2412
2OACH 3612
2OACH 3632
2OACH 3634
2OACH 6012
2OACH 6032
2OACH 6034
Cooling Capacity (Btu/Hr) @ARI 80º - 67º at 52% relative humidity
1 Ton/ 11,800
1.5 Ton/ 16,800
2 Ton/ 24,020
3 Ton/ 36,050
3 Ton/ 36,050
3 Ton/ 36,050
5 Ton/ 60,050
5 Ton/ 60,050
5 Ton/ 60,050
Heating Capacity (Btu/Hr)@ ARI 70ºF – 60º at 60% relative humidity
11,000 15,600 24,020 32,500 32,500 32,500 53,500 53,500 53,500
Electronic Features(Control Panel/Thermostat Control)
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
low voltage solid state
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Air Flow Condenser (CFM) 580 930 1010 1390 1390 1390 2200 2200 2200
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 10.4 14.1 14.9 18.1 17.2 8.7 32.0 20.4 14.8
NEMA Plug Configuration 5-15P 5-20P 6-20P 6-30P L15-30P L16-20P 6-50P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
12/3 10 ft
10/4 10 ft
10/4 10 ft
8/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 25 x 37 24 x 30 x 46 24 x 30 x 46 28 x 35 x 51 28 x 35 x 51 28 x 35 x 51 28 x 39 x 53 28 x 39 x 53 28 x 39 x 53
Weight (LBS) 180 260 260 365 365 380 485 485 515
Humidity Removedat 60% RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
Drain Tank Capacity (GAL) 5 5 5 5 5 5 Auto Pump Auto Pump Auto Pump
410A Charge (OZ) 18 40 37 66 66 66 80 80 80
Sound Level w/Duct (dB(A)) 54 60 65 69 69 69 78 78 78
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-1 AC-2 AC-2 AC-6 AC-6 AC-6 AC-6 AC-6 AC-6
Heresite Coated Coils HC-1 HC-2 HC-2 HC-6 HC-6 HC-6 HC-6 HC-6 HC-6
FIELD-INSTALLED ACCESSORIES
Nozzle Kit 2NK-1 2NK-2 2NK-2 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3 2NK-3
Ceiling Kit 2 x 2 CK-12 CK-12 CK-12 CK-16 CK-16 CK-16 CK-16 CK-16 CK-16
Cond. Return Air Plenum 2DCP-1 2DCP-2 2DCP-2 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5 DCP-5
Evap. Return Air Plenum DEP-10 2DEP-12 2DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Condensate Pump 2DPC-1 2DPC-1 2DPC-2 2DPC-2 2DPC-2 2DPC-2 STD STD STD
Duct Adapter 2DDA-6 2DDA-10 2DDA-10 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16 2DDA-16
144577 Spot Coolers Reference Guide 2014.indd 13 5/21/14 12:12 PM
Portable Water Cooled Air Conditioners
SPECIFICATIONS OWC 1211
OWC 1811
OWC 2412
OWC 3612
OWC 3632
OWC 3634
OWC 6012
OWC 6032
OWC 6034
Cooling Capacity (Btu/Hr)@ ARI 80ºF – 67º at 52% relative humidity
1 Ton/ 12,000
1.5 Ton/ 18,000
2 Ton/ 23,950
3 Ton/ 36,100
3 Ton/ 36,100
3 Ton/ 36,100
5 Ton/ 60,100
5 Ton/ 60,100
5 Ton/ 60,100
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 8.1 11.3 9.9 12.0 9.3 4.7 23.7 16.5 6.3
NEMA Plug Configuration 5-15P 5-15P 6-20P 6-20P L15-20P L16-20P 6-30P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
14/3 10 ft
14/4 10 ft
10/4 10 ft
10/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 13 x 32 25 x 13 x 38 25 x 13 x 38 27 x 18 x 51 27 x 18 x 51 27 x 18 x 51 29 x 39 x 53 29 x 39 x 53 29 x 39 x 53
Weight (LBS) 110 150 160 240 240 270 460 460 520
Humidity Removedat 60% RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
410A Charge (OZ) 14 18 16 24 24 24 52 52 52
Sound Level (dB(A)) 52 57 60 62 62 62 69 69 69
Condensate Pump Lift (FT) 20 20 20 20 20 20 20 20 20
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-3 AC-4 AC-4 AC-5 AC-5 AC-5 AC-5 AC-5 AC-5
Heresite Coated Coils HC-3 HC-4 HC-4 HC-5 HC-5 HC-5 HC-5 HC-5 HC-5
FIELD-INSTALLED ACCESSORIES
Nozzle Kit NK-1 NK-2 NK-2 2NK-3 2NK-3 2NK-3 NK-3 NK-3 NK-3
Evap. Return Air Plenum DEP-10 DEP-12 DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Hose Kit 10 ft. HK-1 HK-1 HK-1 HK-3 HK-3 HK-3 HK-3 HK-3 HK-3
Hose Kit 25 ft. HK-2 HK-2 HK-2 HK-4 HK-4 HK-4 HK-4 HK-4 HK-4
Hose Kit 40 ft. HK-5 HK-5 HK-5 HK-6 HK-6 HK-6 HK-6 HK-6 HK-6
Duct Adapter DDA-6 DDA-10 DDA-10 2DDA-16 2DDA-16 2DDA-16 DDA-16 DDA-16 DDA-16
Specialty Coolers
*
SPECIFICATIONS CAC 1211 CM12 * CM25 * CMW30 * OPW20 * TTS3200
Cooling Capacity (95º at 60% RH) (Btu/Hr) 12,000 10,500 25,000 29,400 15,700 28,000
Air Flow Evaporator(CFM, High/Low) 400/320 324/228 950/800 1060/840 565/540 944
Voltage 115/1 115/1 208-230/1 208-230/1 115/1 208-230/1
Min-Max Voltage 105-125 105-125 198-250 198-250 105-125 187-253
Power Consumption (KW) 1.18 1.23 2.9 1.99 1.27 4.2
Current Consumption (AMPS) 12.0 11.2 12.6 8.9 11.7 21.0
Circuit Breaker Size (AMPS) 15 15 20 20 15 30
NEMA Plug Configuration 5 - 15P N/A N/A N/A 5-15P 6-30P
Dimensions W x D x H (IN) 17.25 x 24 x 25 35 x 23 x 16 57 x 36 x 20 49 x 35 x 20 21 x 27 x 41.5 34 x 15 x 50
Weight (Net Weight/Shipping Weight) (LBS) 135/160 123/137 310/353 236/271 178/209 280
Thermostat Standard Not Included Standard Standard Standard Standard
SPECIFICATIONS 5T 208-1ph
5T 208-3ph
5T 460-3ph
12TS 208-3ph
12TS 460/3ph
12T 208-3ph
12T 460-3ph
Cooling Capacity (BTU) 5 Ton/63,500 5 Ton/63,500 5 Ton/63,500 12 Ton 143,000
12 Ton 143,000
12 Ton 144,000
12 Ton 144,000
Heating Capacity (BTU) Optional Optional Optional Optional Optional Optional Optional
Air Flow Evaporator (CFM) 2,000 2,000 2,000 4,000 4,000 4,800 4,800
Voltage 208-230/60/1
208-230/60/3 460/60/3 208/230/3 460/60/3 208-
230/60/3 460/60/3
Power Consumption (KW) 7.7 9.3 9.3 18.2 20.2 20 22.9
Current Consumption (AMPS) 53 35 16 59.6 30.4 74 36
Circuit Breaker Size (AMPS) 60 50 30 90 45 100 60
NEMA Plug Configuration Camlock Camlock Camlock Camlock Camlock Camlock Camlock
Dimensions W x D x H (IN) 34 x 57 x 43 34 x 57 x 43 34 x 57 x 43 34.5 x 78 x 71 34.5 x 78 x 71 46 x 68 x 59 46 x 68 x 59
Weight (LBS) 675 675 675 1,450 1,200 1,200 1,200
144577 Spot Coolers Reference Guide 2014.indd 14 5/21/14 12:12 PM
SPECIFICATIONS OWC 1211
OWC 1811
OWC 2412
OWC 3612
OWC 3632
OWC 3634
OWC 6012
OWC 6032
OWC 6034
Cooling Capacity (Btu/Hr)@ ARI 80ºF – 67º at 52% relative humidity
1 Ton/ 12,000
1.5 Ton/ 18,000
2 Ton/ 23,950
3 Ton/ 36,100
3 Ton/ 36,100
3 Ton/ 36,100
5 Ton/ 60,100
5 Ton/ 60,100
5 Ton/ 60,100
Air Flow Evaporator (CFM) 400 600 810 1200 1200 1200 1950 1950 1950
Operating Conditions (Min-Max) 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF 55º-105ºF
Voltage 115/1 115/1 208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Min-Max Voltage 105-125 105-125 187-253 187-253 187-253 414-506 187-253 187-253 414-506
Current Consumption (AMPS) 8.1 11.3 9.9 12.0 9.3 4.7 23.7 16.5 6.3
NEMA Plug Configuration 5-15P 5-15P 6-20P 6-20P L15-20P L16-20P 6-30P L15-30P L16-20P
Power Cord (Gauge/Length) 14/3 10 ft
14/3 10 ft
14/3 10 ft
14/3 10 ft
14/4 10 ft
10/4 10 ft
10/3 10 ft
10/4 10 ft
10/4 10 ft
Dimensions W x D x H (IN) 20 x 13 x 32 25 x 13 x 38 25 x 13 x 38 27 x 18 x 51 27 x 18 x 51 27 x 18 x 51 29 x 39 x 53 29 x 39 x 53 29 x 39 x 53
Weight (LBS) 110 150 160 240 240 270 460 460 520
Humidity Removedat 60% RH (GAL/HR) 0.85 1.1 1.7 2.2 2.2 2.2 4.1 4.1 4.1
410A Charge (OZ) 14 18 16 24 24 24 52 52 52
Sound Level (dB(A)) 52 57 60 62 62 62 69 69 69
Condensate Pump Lift (FT) 20 20 20 20 20 20 20 20 20
FACTORY-INSTALLED ACCESSORIES
Acrylic Coated Coils AC-3 AC-4 AC-4 AC-5 AC-5 AC-5 AC-5 AC-5 AC-5
Heresite Coated Coils HC-3 HC-4 HC-4 HC-5 HC-5 HC-5 HC-5 HC-5 HC-5
FIELD-INSTALLED ACCESSORIES
Nozzle Kit NK-1 NK-2 NK-2 2NK-3 2NK-3 2NK-3 NK-3 NK-3 NK-3
Evap. Return Air Plenum DEP-10 DEP-12 DEP-12 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16 DEP-16
Hose Kit 10 ft. HK-1 HK-1 HK-1 HK-3 HK-3 HK-3 HK-3 HK-3 HK-3
Hose Kit 25 ft. HK-2 HK-2 HK-2 HK-4 HK-4 HK-4 HK-4 HK-4 HK-4
Hose Kit 40 ft. HK-5 HK-5 HK-5 HK-6 HK-6 HK-6 HK-6 HK-6 HK-6
Duct Adapter DDA-6 DDA-10 DDA-10 2DDA-16 2DDA-16 2DDA-16 DDA-16 DDA-16 DDA-16
Portable Trailer-Mounted Air Conditioners
Specialty Coolers
MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation
*
800.367.8675 www.spot-coolers.com
SPECIFICATIONS CAC 1211 CM12 * CM25 * CMW30 * OPW20 * TTS3200
Cooling Capacity (95º at 60% RH) (Btu/Hr) 12,000 10,500 25,000 29,400 15,700 28,000
Air Flow Evaporator(CFM, High/Low) 400/320 324/228 950/800 1060/840 565/540 944
Voltage 115/1 115/1 208-230/1 208-230/1 115/1 208-230/1
Min-Max Voltage 105-125 105-125 198-250 198-250 105-125 187-253
Power Consumption (KW) 1.18 1.23 2.9 1.99 1.27 4.2
Current Consumption (AMPS) 12.0 11.2 12.6 8.9 11.7 21.0
Circuit Breaker Size (AMPS) 15 15 20 20 15 30
NEMA Plug Configuration 5 - 15P N/A N/A N/A 5-15P 6-30P
Dimensions W x D x H (IN) 17.25 x 24 x 25 35 x 23 x 16 57 x 36 x 20 49 x 35 x 20 21 x 27 x 41.5 34 x 15 x 50
Weight (Net Weight/Shipping Weight) (LBS) 135/160 123/137 310/353 236/271 178/209 280
Thermostat Standard Not Included Standard Standard Standard Standard
SPECIFICATIONS 5T 208-1ph
5T 208-3ph
5T 460-3ph
12TS 208-3ph
12TS 460/3ph
12T 208-3ph
12T 460-3ph
Cooling Capacity (BTU) 5 Ton/63,500 5 Ton/63,500 5 Ton/63,500 12 Ton 143,000
12 Ton 143,000
12 Ton 144,000
12 Ton 144,000
Heating Capacity (BTU) Optional Optional Optional Optional Optional Optional Optional
Air Flow Evaporator (CFM) 2,000 2,000 2,000 4,000 4,000 4,800 4,800
Voltage 208-230/60/1
208-230/60/3 460/60/3 208/230/3 460/60/3 208-
230/60/3 460/60/3
Power Consumption (KW) 7.7 9.3 9.3 18.2 20.2 20 22.9
Current Consumption (AMPS) 53 35 16 59.6 30.4 74 36
Circuit Breaker Size (AMPS) 60 50 30 90 45 100 60
NEMA Plug Configuration Camlock Camlock Camlock Camlock Camlock Camlock Camlock
Dimensions W x D x H (IN) 34 x 57 x 43 34 x 57 x 43 34 x 57 x 43 34.5 x 78 x 71 34.5 x 78 x 71 46 x 68 x 59 46 x 68 x 59
Weight (LBS) 675 675 675 1,450 1,450 1,200 1,200
144577 Spot Coolers Reference Guide 2014.indd 15 5/22/14 11:39 AM
Copyright©2014 • Spot Coolers is a division of United Technologies
800.367.8675www.spot-coolers.com
With 37 locations around the country
Spot Coolers is in your neighborhood wherever you are!
We provide instant relief from the heat when you need it,
where you need it, seven days a week!
San Francisco
Denver
Sacramento
Los Angeles
Orange County
Phoenix
DetroitCleveland
PittsburghChicago
IndianapolisCincinnatti
Nashville
St. Louis
Minneapolis
Kansas City
Oklahoma City
New Orleans
Houston
Austin
Dallas
Boston
New York
Philadelphia
BaltimoreWashington
Charlotte
Birmingham
Jacksonville
Orlando
Boca Raton
Miami
Tampa
Atlanta
S P O T C O O L E R S C O U N T R Y
Portable Air Conditioning and Heating
Memphis
Raleigh
Totowa
144577 Spot Coolers Reference Guide 2014.indd 16 5/21/14 12:13 PM