+ All Categories
Home > Documents > Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98...

Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98...

Date post: 18-Jan-2021
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
19
भारत सरकार अंत�रक �वभाग अंत�रक उपयोग क� �(इसरो) आंबावाड� �वसतार पप.ओ. अहमदाबाद – 380 015 (भारत) दूरभाषः +91-79-2691 3051/98 फै कस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE APPLICATIONS CENTRE (ISRO) Ambawadi Vistar P.O. Ahmedabad – 380 015 (INDIA) Telephone : +91-79 – 2691 3051/98 Fax No. : +91-79 – 2691 5835 / 02 /48 Email: [email protected] ईओआई सूचना सं. : सैक / ईओआई / 05 / 2015-16 EOI Notice No.: SAC / EOI / 05 / 2015-16 भारत के रा�पित के िलए और उनक� ओर से, व�र. �धान, �य एवं भंडार,अंत�रक उपयोग क� �, अहमदाबाद , िनमनिलल�त के िलए इचछक �व�ेता से अिभभिच क� अिभिय� (ईओआई) आमं��त करते ह �। For and on behalf of the President of India, Sr. Head, Purchase & Stores, Space Applications Centre, Ahmedabad invites Expression of Interest (EOI) from interested vendors for the following. संलक �ववरण Brief Description िनयत ितिथ (अपरा� 3 बजे तक) Due Date (Up to 3:00 pm) Establishment of Device Modeling Setup at SAC, Ahmedabad 29-02-2016 कृ पया अपने �वसतृत �यछतर मोहरबंद िलफाफे म� िनयत ितिथ 29-02-2016 (15.00 Hrs. IST) तक या इससे पूवर अधोहसताकर� को भेज�। Please submit detailed response to the undersigned on or before due date 29-02-2016 (15.00 Hrs. IST) in sealed cover. व�र.�धान, �य एवं भंडार Sr. Head, Purchase & Stores
Transcript
Page 1: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

भारत सरकार

अतं�रक �वभाग

अतं�रक उपयोग क� �(इसरो) आंबावाड� �वसतार पप.ओ.

अहमदाबाद – 380 015 (भारत)

दरूभाषः +91-79-2691 3051/98

फैकस नं. : +91-79-2691 5835/02/48

Government of India

Department of Space

SPACE APPLICATIONS CENTRE (ISRO) Ambawadi Vistar P.O.

Ahmedabad – 380 015 (INDIA)

Telephone : +91-79 – 2691 3051/98

Fax No. : +91-79 – 2691 5835 / 02 /48 Email: [email protected]

ईओआई सूचना सं.: सैक / ईओआई / 05 / 2015-16 EOI Notice No.: SAC / EOI / 05 / 2015-16 भारत के रा�पित के िलए और उनक� ओर से, व�र. �धान, �य एवं भंडार,अतं�रक उपयोग क� �, अहमदाबाद , िनमनिलल�त के िलए इच छ् क �व�ेता से अिभभिच क� अिभिय�्

(ईओआई) आमं��त करते ह�। For and on behalf of the President of India, Sr. Head, Purchase & Stores, Space Applications Centre, Ahmedabad invites Expression of Interest (EOI) from interested

vendors for the following.

सलंक् �ववरण Brief Description

िनयत ितिथ (अपरा� 3 बजे तक) Due Date (Up to 3:00 pm)

Establishment of Device Modeling Setup at SAC, Ahmedabad 29-02-2016

कृपया अपने �वसततृ ��यछतर मोहरबंद िलफाफे म� िनयत ितिथ 29-02-2016 (15.00 Hrs.

IST) तक या इससे पूवर अधोहसताकर� को भेज�। Please submit detailed response to the undersigned on or before due date 29-02-2016 (15.00 Hrs. IST) in sealed cover.

व�र.�धान, �य एवं भंडार Sr. Head, Purchase & Stores

Page 2: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

1

Request for

EXPRESSION OF INTEREST For

Establishment of device modeling setup at SAC,Ahmedabad

SPACE APPLICATIONS CENTRE

INDIAN SPACE RESEARCH ORGANISATION

GOVERNMENT OF INDIA

AHMEDABAD - 380 015

INDIA

Page 3: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

2

CONTENTS

Sr. No.

Description Page No.

1. Introduction, Scope 3

2. Specifications: Overall requirement 4-5

3. Device modeling software specifications 5-7

4. Parametric analyzer specifications 7-9

5. Vector Network analyzer specifications 10-13

6. Device Modeling Setup Installation and Training 14-15

7. General guidelines to the vendor 15-16

8. Annexure-1 (Summit 9000 probe station details) 17-18

Page 4: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

3

Device characterization and modeling setup

Introduction: Space Applications Centre (SAC) is setting up Device characterization and modeling setup for developing models for in-house developed devices as well as devices made at outside foundries. Types of devices for which modeling is planned are GaAs HEMT, GaN HEMT and Graphene FET etc. Cascade Microtech’s Summit 9K Probe station is already available at SAC. Expression Of Interest (EOI) is invited from interested parties for establishing device modeling setup at SAC. The proposed tools shall be compatible for future upgrades of standard probe stations also. The setup shall be a turn key solution consisting of device modelling software, Parametric Analyzer, Vector Network Analyzer, integration hardware etc. to make the complete integrated setup. SAC reserves the right to create a list of competent vendors based on vendors’ response to this EOI and only these identified vendors shall be eligible to participate in the final RFP. Scope: The offered solution shall have capability of characterization and extraction of measurement based model parameters using proposed device model set-up. Vendor shall provide complete flow of device model parameter extraction. Both linear and non-linear models are to be covered under the scope. It should be possible to export the extracted models to the microwave design softwares like ADS or Microwave office (MWO) and should able to simulate the circuit using these models in order to complete the purpose. The vendor may be required to demonstrate complete system as a part of technical evaluation of offer within India (preferably on site i.e. at SAC,Ahmedabad).

Page 5: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

4

Specifications:

(1) Overall requirement

Sr. No. Specifications Compliance

Y /N

Exact

specification with

values

1.1

The entire setup for Device Modeling and Characterization should consist of

Device Modeling software and Instrumentation as given below.

Minimum setup configuration

(1) Device modelling software

(2) Parametric analyzer

(3) Vector network analyzer (10 MHz to 67GHz)

(4) Hardware and accessories for integration

1.2

During technical evaluation of the responses received against EOI, if required,

SAC may ask the vendor to give demonstration at SAC,Ahmedabad, of the

proposed models with all the options and accessories required to meet the tender

specifications, with the prior intimation of nominally thirty days. Demonstration

of instrument shall not be considered as final acceptance of the bid. Vendor to

bring all above instrument, software along with controller as per the compliance

to demonstrate the device Modelling flow, SAC will provide the devices, its

details and Probe station (Annexure-1).

1.3 It will be responsibility of the vendor to integrate the complete system setup at

SAC, Ahmedabad with existing Cascade Probe station (Annexure-1).

1.4 It will be responsibility of the vendor to demonstrate the complete modeling

flow using the software and instruments independently at SAC, Ahmedabad.

Page 6: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

5

(2) Device modeling software Specifications

1.5 The integrated setup should provide the capability for complete DC and RF

characterization, extraction and modeling of a semiconductor device like GaAs

or GaN HEMT.

1.6 Using extracted models it should be possible to do linear and non-linear

simulation for circuits like mixer, power amplifier etc. in microwave design

softwares like ADS or MWO.

1.7

Vendor needs to demonstrate the complete measurement and modeling flow

with this setup for the GaAs HEMT devices available with SAC. For which

SAC will provide device layout and actual devices only. Details of the device

and range over which models are to be developed is given below.

Device Type 130nm mHEMT

Frequency range DC to 65 GHz

Device gate bias range (Vg) -1 V to 0 V

Device drain bias range (Vd) 0 V to 3.5 V

Type of model Linear, non-linear, transient

Input RF Power range -60 dBm to +5 dBm

1.7

All accessories and components required to integrate parametric analyzer,

Vector network analyzer, Device modelling software with existing probe station

(Annexure-1) should be part of the proposal.

Sr. No. Specifications Compliance

Y /N

Exact

specification

with values

2.1 Device modeling software should be capable of extracting the device model

Page 7: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

6

parameters using measured DC and RF data through Parametric Analyzer and

Vector Network Analyzer respectively. It is preferable that all these

measurements should be made in single connection.

2.2

Modeling packages

Software should extract High frequency FET model parameters from a

combination of DC and S-parameter measurements. Software should able to

extract both linear and non-linear models.

Software should include high frequency FET and HEMT modeling packages.

Extraction for standard models like EEHEMT1, Angelov (or equivalent

suitable for GaAs and GaN HEMT) is required.

It should be possible to export the extracted models to commercial microwave

design softwares like ADS or Microwave office for simulation of circuits.

2.3

Design Environment

It should be possible to create and manage measurement and modeling related

projects using the software.

It should be possible to read and display data using window displays.

2.4

Scripting Language

Software should allow use of scripting language to develop new extraction

modules and modify existing extraction modules.

2.5

Data management

Device modeling software should allow import/export of data in formats like

.S2P, ASCII, .CSV etc.

2.6

Optimizers

For model fitting powerful optimization algorithms should be part of the

software.

Page 8: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

7

(3) Parametric analyzer (for DC characterization) specifications

Sr. No. Specifications Compliance

Y /N

Exact

specification

with values

3.1 Parametric Analyzer having capability of measuring/providing Gate current &

voltage and Drain current & voltage together. It is also preferred if in addition to

above it can measure/provide current & voltage for Source and Substrate

simultaneously for complete characterization of device. For above requirement

Optimizers should able to fit large numbers of model parameters using large

number of data sets.

2.7

Instrument connectivity

It should support DC and AC instrument drivers. It is preferable that software

supports CV, Time domain and Noise instrument drivers also. Using these

drivers software should able to control and automate the measurement

instruments required to characterize device or circuit.

2.8

Operating System

Device modeling software should support Windows 7 or higher version.

2.9

License Support

Vendor should provide perpetual license. Vendor to provide 3 year upgrade and

support for the software. Vendor should show his willingness for 2 year

extended support as optional.

2.10

Localized support

The EDA vendor shall offer strong regional support.

Technical support should be provided both remotely and locally.

Page 9: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

8

Medium Power Source Measurement Units, High Power Source Measurement Units

are to be provided with their specifications as mentioned below. Detailed

requirement for Pulse I/V unit and multi frequency capacitance measurement unit is

also mentioned below.

3.2 Medium Power Source

Measurement Units(2 Numbers)

Range

Resolution

Range up to 100 mA/100V(up to 2W Power)

Resolution of 10fA / 1uV or better

3.3 High Power Source Measurement

Units (2 Numbers)

Range

Resolution

Range up to 1A/200V (up to 20W Power)

Resolution of 10fA / 2uV or better

3.4 Ground Unit

Sink current

Output Voltage

> 4 A

0V ±100µV

3.5 Sweep Measurements User should able to sweep current/voltage

through software.

Source measurement units should support range

management feature that can prevent damage of

sensitive devices when making sweep

measurements.

3.6 Capacitance Measurement

It should be possible to perform measurements

like

Capacitance versus Voltage (up to ±100V),

Capacitance versus Frequency (range 1kHz to

5MHz or more),

Capacitance versus Time.

3.7 Pulse IV system

Source & Measure unit

Pulse IV system should able to generate and

measure pulse with following specifications.

Pulse Amplitude: up to ±40 V.

Pulse width: ≤ 5µs

3.8 Current versus Voltage (IV) and

Capacitance versus Voltage (CV)

Switching unit should able to switch between

Source Measurement Unit & Capacitance

Page 10: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

9

measurement switching

Measurement Unit, to do IV & CV

measurement without physically changing the

connection with the required accessories to

perform the measurements.

3.9 Application Libraries Application libraries for testing FET, HEMT

etc. are to be provided.

3.10 Operating System Should support Windows 7 or higher version

3.11 User Interface Options USB, LAN, GPIB interfaces.

USB keyboard & mouse.

12 inch or more display preferred.

3.12 Device Modeling software

support and integration with

Vector Network Analyzer

Hardware should support device modeling

software. It should be possible to integrate the

parametric analyzer with Vector Network

Analyzer which is used for the RF

measurement.

3.13 Adaptors & Accessories All standard cables, adaptors and other

necessary accessories which are required to

perform device modeling are to be provided.

3.14 Future upgradability It should be possible to upgrade for high

voltage (1KV or more), high current (30A or

more), options for existing set up.

3.15 Power supply 240V ± 10%, 50 Hz operation

3.16 Operating temperature range 20° C to 28° C

3.17 Warranty 3 years min. (5 years optional)

Page 11: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

10

(4) Vector Network Analyzer Specifications

Sr No Parameter Specification Compliance

Y /N

Exact

specification

with values

4.1 Frequency Range 10 MHz to 67GHz

4.2 Number of independent internal sources 1 min.

4.3 Number of test ports with internal bias tees 2 min.

4.4 Instrument test port connector type 1.85 mm coaxial

4.5 Test port impedance 50 ohms

4.6

Maximum Source Output Power (for all ports)

50 MHz to 20 GHz > +4 dBm

20 GHz to 50 GHz > 0 dBm

50 GHz to 67 GHz > 0 dBm

4.7 Frequency Reference Aging Rate ± 0.5 ppm/year or better

4.8 IF Bandwidth 1 Hz to 1 MHz (min.)

4.9 Directivity (over full band) ≥ 30 dB

4.10 Source and load match (over full band) ≥ 28 dB

4.11 Reflection and transmission tracking

(over full band) ≤ ± 0.2 dB

4.12

Transmission measurement accuracy

for +5 dB to -30 dB over,

50 MHz to 30 GHz Magnitude < 0.3 dB

Phase < 2 degrees

30 GHz to 67 GHz Magnitude < 0.3 dB

Phase < 2 degrees

Page 12: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

11

4.13 Dynamic Range beyond 100MHz ≥ 90 dB

4.14 Damage input power level ≥ +20 dBm

4.15 Sweep type Frequency: linear, segmented, CW; Power

4.16 No. of measurement points per trace ≥ 32,000

4.17 No. of channels ≥ 16

4.18 No. of traces in each channel ≥ 10

4.19

Calibration kits:

(1) E-cal kit with suitable interface cable One, for full band

(2) Mechanical Cal Kit w/o sliding load One set, for full band

4.20

Standard test port flexible cables compatible to

meet equipment specifications of length ≥ 2 feet

with 1.85 mm connector type at both instrument

and DUT ports.

1 for each of the instrument ports

4.21

Suitable 1.85 mm precision calibration grade

adapters for measurement of DUTs with 1.85

mm (female) ports

1 for each of the cables in item 20

4.22

Suitable 1.85 mm to 2.92 mm precision

calibration grade adapters for measurement of

DUTs having 2.92 mm (female) ports

1 for each of the cables in item 20

4.23 Measurement requirements

S-Parameter Measurements

Measurement of all four S-parameters (mag

and phase), group delay for entire operating

frequency range.

All necessary hardware options, test

accessories & application software required

for above measurements should be provided.

Pulsed RF Measurements

Pulsed RF measurement over entire

operating frequency range, with pulse

widths below 500ns.

All necessary hardware options, test

accessories & application software required

Page 13: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

12

for above measurements should be provided.

4.24 S-parameter Embedding/De-embedding feature Required

4.25 Interfaces 4 X USB 2.0 or higher , GPIB, LAN

4.26 Built in colour display 8” or larger (desirable)

4.27 Supply Voltage 230 V, 50 Hz (nom. op.)

4.28 Operating Temperature range 20° C to 28° C

4.29 Other required accessories

1. Spanner for fixing cables to VNA port,

one set

2. Compatible torque wrench sets for both

1.85 mm and 2.92 mm connectors

3. Compatible keyboard and mouse

4.30 Compatibility to Device modeling &

characterization applications

The above mentioned 67GHz VNA

configuration should be compatible to

semiconductor device measurement and

device modeling applications.

It should have seamless connectivity with

equipments like parametric analyzer and

industry standard device modeling software.

4.31 Upgradability of VNA to 110GHz Measurement

setup

The above mentioned 67GHz VNA

configuration should be upgradable to

millimeter wave frequency band (upto 110

GHz) in single sweep mode at user end.

Vendor to provide a list of accessories

and/or software options required for this

upgradation.

4.32 Warranty 3 years min. (5 years optional)

4.33 Optional Requirements

(1) Noise Figure Measurements

Fully corrected noise figure measurement

upto 50GHz.

(2) Gain compression test capability

Gain Compression measurements with

support of associated compression

Page 14: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

13

parameters like Input Power, Output Power

and Gain at Compression Point.

(3) Intermodulation distortion test capability

Inter-modulation spectrum (IMD)

measurements on amplifiers for entire

frequency range. Instrument should have

capability to generate & combine internally,

two calibrated and leveled tones for IMD

measurements.

(4) Internal source/generator attenuators for

each of the ports

Vendor should optionally give details for

step attenuators for each of the ports.

All necessary hardware options, test

accessories & application software required

for above measurements should be provided.

VNA configuration should be able to do all

measurements: S-parameters, noise figure,

IMD, gain compression in a single session

without disconnecting the DUT.

Page 15: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

14

(5) DEVICE MODELING SETUP INSTALLATION AND ON-SITE TRAINING 5 DEVICE MODELLING TRAINING Compliance

Y /N

Exact

specification with

values

5.1 Vendor should be able to provide specific training & extraction of device

modeling on the following device which will be provided by SAC.

Device : 130nm mHEMT (Ft= 150 GHz)

Model parameters for 130nm mHEMT are to be extracted over following range.

Frequency range: DC to 65 GHz

Device gate bias range (Vg): -1 V to 0 V

Device drain bias range (Vd): 0 V to 3.5 V

Type of model: Linear, non-linear, transient

Input RF Power range: -60 dBm to +5 dBm

5.2 SAC will provide above device layout and actual devices only. Vendor

should take measurements data as required by the modeling software using the established device modeling setup at SAC.

5.3 Extract EEHEMT model parameters for SAC’s device. The Model extracted should be directly usable in microwave design softwares like ADS or MWO.

5.4 Deliver the training using parameter extraction results and modeling

software for minimum 2 days at SAC which include;

Modeling training for measurement part

Modeling training for extraction part

Complete training material is to be provided to SAC by the vendor.

Page 16: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

15

5.5 Following should be the final deliverables to SAC: i. Extraction Report(should be available to SAC within 6 weeks after taking measurements) ii. EEHEMT (or equivalent suitable for GaAs HEMT) Model parameters (should be directly usable in ADS or MWO software) iii. EEHEMT Modeling Package. iv. 2-days of Onsite training should be provided to SAC covering: - EEHEMT model training for measurement part - EEHEMT model training for extraction part

GENERAL GUIDELINES TO THE VENDOR

The vendor is requested to acknowledge the receipt of this EOI and his willingness/ability to respond against this EOI.

The vendor is requested to examine the EOI thoroughly and offer compliance/non-compliance point by point. In case of

non-compliance, the deviation from the specified parameter shall be furnished and for complied parameters the vendor

specification (better or same) shall be provided. Vendors are also advised to give their comments with proper

justification if some parameter details are to be highlighted by the vendor.

Vendor should provide point by point compliance to the requirements along with reference to the corresponding page

number of the data sheet/product literature. Specifications for which no data is available in data sheet, vendor has to

provide certificate of compliance along with measurement results to satisfy the technical requirement.

Response to EOI should be supplied either directly by the manufacturer or their authorized Indian representatives

(authorization certificate to be enclosed).

Operation, programming, calibration and service manual must be provided with the instruments.

Page 17: Sr. Head, Purchase & Stores · 2016. 1. 26. · दरभाषःू +91-79-2691 3051/98 फैकस नं. : +91-79-2691 5835/02/48 Government of India Department of Space SPACE

16

Warranty and post warranty service should preferably be available in India.

Service and spares support should be available for minimum 10 years after satisfactory installation.

It will be the responsibility of supplier to provide all the essential accessories to make system fully functional.

Installation and training/demonstration at site for minimum three days should be provided for the setup including

software at free of cost.

Technical support for one year for complete system including device modeling flow.

The requirement is for only new equipment.

Vendor must submit block diagrams for the measurement test setup. The block diagram should clearly show all the

accessories/ options etc. needed for these measurements