DATE-20TH MARCH 2019
Sr. No. DESCRIPTION AMOUNT PER SQFT
Area in SQFT 10,090
A INTERIOR FIT OUT WORKS
A1 CIVIL & INTERIOR WORKS - 0
A2 TOILET WORKS - 0
A3 MODULAR FURNITURES ( Indian Make) - 0
A4 CHAIRS & SOFA's ( Indian Make) - 0
A5 CARPET ( Nylon) - 0
A6 CENTRAL ZONE - 0
B ELECTRICAL WORK
B1 ELECTRICAL WORKS - 0
B2 LIGHT FIXTURE - 0
B3 DECORATIVE LIGHT - 0
C SECURITY SYSTEM
C1 FIRE ALARM SYSTEM - 0
C2 PA SYSTEM - 0
C3 CCTV SYSTEM (8 Nos of Camera) - 0
C4 ACCESS CONTROL SYSTEM - 0
C6 FIRE EXTINGUISHER - 0
C8 SPRINKLER SYSTEM - 0
D HVAC
D1 HVAC HIGH SIDE - 0
D2 HVAC LOW SIDE - 0
E NETWORKING WORK
STRUN/R0
AT VISHWAROOP BUILDING - Vashi
PROPOSED INFRASTRUCTURE DEVELOPMENT FOR
STAR UNION DAI-ICHI- 4 TH FLOOR
E1 PASSIVE COMPONENTS - 0
TOTAL COST IN INR - -
EXCLUSION
A MATHADI CHARGES
B DEVELOPER SCOPE OF WORK - 0
C HVAC HIGH SIDE ( AHU) - 0
D NETWORKING WORK ( Redudunt point for each workstation &
fiber cable )- 0
TOTAL OF EXCLUSION - - PAGE 1 OF 2
Note:
1 Owner/client to provide free of cost electricity/water/security
2
3
4
5
6
7
Payment Terms:
1 25% Advance along with PO/LOI
2 25% on Delivery of materials of 25% of the Work
3 25% on completion of 50% of the Work
4 15% on completion of 80% of the Work
5 5% on Prefinal bill
6 5% on Retention
NOTE :- Following is not included in the BOQ
1SERVER RACKS/ METER / UPS/ AHU/EXTERIOR
FAÇADE WORKS
2
3
4 REFUGE AREA GLASS FILM
5 EXCLUDING LIFT LOBBY BEAUTIFICATION
6 BTU meter to be supplied & installed by base builder.
THANKING YOU
WHITE GOODS / BAIN MARIE /SHREDDERS /
Eelevator to be permitted for materials loading & unloading site floor.
ACTIVE COMPONENTS/SWITCHES AND NETWORK ROUTERS/
Owner/client to provide dedicated area for loading/unloading material
Materials loading & unloading through staircase will be extra
The costing as projected here above shall change as per the changes
above cost conisder for normal working hrs 9 am to 6 pm if work need
the above cost may vary as per the actual measurements on site, as
Nos ITEM SPECIFICATION LOCATION UNIT QTY RATE AMOUNT
1.00 PEST CONTROL
1.01 PEST CONTROL
Providing Pest control and Anti-termite treatment by appointing a specialized agency as per the specifications
mentioned by the Bureau of Indian Standards and Agencies specifications (whichever is higher), for General Civil,
Plumbing/ Drainage and timber/ Carpentry works, Gypsum related work, including a 5-year guarantee under suitable
undertaking on stamp paper etc., complete as directed. ( Mode of measurement to be on carpet-area of floor and not
the area of surface treated.)
ENTIRE OFFICE SFT 8,400
2.00
DEMOLISHING &
PLASTERING
EXISTING WALLS
2.01DEMOLISHING
OF EXISTING
FLOORING
Demolishing of Existing FLOORING PASSAGE SFT -
2.02REMOVING OF
DEBRISDisposal of Debris from site to an identified location by client ENTIRE OFFICE Nos 8
3.00MASONARY
WORK
3.01
AERATED LIGHT
WEIGHT WALL
OF 100 MM
Providing and constructing Aerated light weight bock masonry wall of 100 mm thick ( Block size ) in cement and
sand mortar in a ratio of 1 : 4 including M-15 Reinforced concrete lintels of 100 x 100 mm size with 4 Nos. 6 mm
rods and 6 mm stirrups @ 600 mm c/c at an equal vertical distance of 1200 mm, raking out joints, curing,
scaffolding, cleaning, etc.
WASH ROOM / SERVER
ROOM & RECPTION BACK
DROP
SFT 1,200
3.02 RCC LINTEL
Providing, laying, compacting and laying in position RCC lintels upto 3'-6" wide & 4" to 6" ht. cast in concrete in 1:2:4
cement concrete with 4 Nos of 8mm TOR steel reinforcement with stirrups of 8mm dia TOR steel at 200mm c/c
,complete.
WASH ROOM / SERVER
ROOM & RECPTION BACK
DROP
Nos 4
3.03
POLYMER
WATERPROOFIN
G
Providing, supplying, mixing and applying two coats of approved ROFF HYSEAL or approved equivalent
waterproofing compound, as per the directions below. Surface preparation should include cleaning the surface of all
dust, oil, grease.
SFT -
3.04 P.C.C WORK
Providing and laying up to 100mm thick cement concrete flooring with cement, sand and aggregate properly mixed in
a ratio of 1 : 2 : 4 or 1 : 21/2 : 31/2. The Cement concrete laid to proper level and slope in alternate bays including
compactions, filling of joints or as directed, etc. complete as per architects instructions. Finished in Smooth cement
Mortar 1:1 of sufficient minimum thickness to give a smooth & even surface and curing etc. complete as per architects
instructions. Cost should be inclusive of hacking the floor so that IPS Adhere to the existing floor The cost shall
inclusive the preparation of the surface rough by chiseling etc for adhering the PCC.
ENTIRE OFFICE SFT 8,200
3.05 IPS FLOOR P/f of IPS flooring SFT -
4.00WALL
PREPARATION
4.01CEMENT
PLASTER
Providing internal cement plaster of 12 mm -15 mm thick in a single coat of cement sand mortar in a ratio of 1 : 4 to
concrete and masonry surfaces in all positions including of hacking of RCC/ wall surfaces, preparing surface before
applying plaster, proper curing, scaffolding, etc. complete. The rate to be inclusive of providing and fixing GI chicken
mesh at the junction of RCC and masonry works with nails, etc. scrapping of surface for plastering.
WASH ROOM / SERVER
ROOM & RECPTION BACK
DROP
SFT 3,200
4.02POP PUNNING
UP TO 13MM THK
Providing and applying punning up to 13 mm thick layer of super fine Plaster of Paris ( anhydrous gypsum ) applied
over selected existing plastered surface on walls and columns finished smooth, surface prepared by hacking, sand
papering and applying a coat of cement slurry if required including all incidentals, making grooves as directed, pattas,
sills, etc. complete. The finished surface should be smooth and in perfect level so as to avoid unevenness and ready
to take on paint. The Rates are inclusive of making Grooves if any
ENTIRE OFFICE SFT 5,000
5.00FLOORING &
CLADDING
5.01EXPANSSION
JOINT FILINGRFT -
5.02ITALIAN MARBLE
FLOORING
Providing and doing with machine cut and machine high pre-polished best quality approved colour Italian Marble slab
of thickness not less than 16 mm thk.,
Rate shall include for preparation of base surface, cleaning, chamfering, edge polishing, with tin-oxide / high gloss
factory polish, provision of 'V' shaped notch cuts along the horizontal and vertical joints of specified size as detailed in
the drawing protection with Gypsum/POP layer over plastic sheet etc. complete, as directed.
BASIC COST OF ITALIAN MARBLE : RS 350/SFT-
RECEPTION AREA / DY CEO
CABIN & MD CABIN AREASFT 900
5.03
2ND QULAITY
TILE BELOW
CARPETS
(CERAMIC )
Ceramic second qulaity tile mulitple colours as available for below carpet. BELOW CARPET SFT 6,300
5.04VITRIFIED TILE
FLOORING
Providing and laying flooring with 600 mm x 600 mm Vitrified Tiles of approved make and sample in pattern as per
detailed drawings on up to 25 mm thick bed of cement sand mortar in a ratio of 1 : 6, including surface preparation,
applying neat cement float, giving necessary slopes, cleaning joints and grouting them in neat white cement paste
with pigmented additives to match shade of the tile. etc. complete. Cost should be inclusive of cement screed in case
the bedding thickness increase beyond 25 mm, it should also include the cost of hacking the existing IPS Floor.(
Basic rates 70 Rs/sqft)
PANTRY AREA & ANTI
CHAMNBER AREASFT 300
5.05 KOTA FLOORING
Providing and laying 19 mm thk slab of machine cut & machine polished 1st grade kota stone of approved shade
and first quality including cutting to any shape as per detailed drawings and set in minimum 12 mm thick cement and
sand mortar of 1:3 including surface preparation, giving necessary slopes, cleaning joints and grouting them in neat
white cement paste with pigmented additives to match shade of the tile etc. complete. Cost should be inclusive of
cement screed in case the bedding thickness increase beyond 25 mm, it should also include the cost of hacking the
existing IPS Floor.
ELECTRICAL ROOM SFT 100
5.06
WOODEN
RAISED
PLATFORM
Providing & Fixing Raised flooring with wooden frame work of size 50mm x 50mm plaed 2'-0" c/c with 19mm thk
marine ply and making in line and level as per design and directed by the architect.SFT -
5.07
FLAMED
GRANITE
FLOORING
Providing and cladding Flammed Granite Skirting of approved make and approved sample in pattern as per detailed
drawings. 100 mm High Skirting shall be fixed in 12 mm thk. bed of C.M 1:3. . The rate should be inclusive of
cleaning joints and grouting them with neat white cement paste with pigmented additives to match shade of the tile
Skirting to be fixed flush with finished surface of wall in line & level and 6 mm wide groove to be made in wall at the
junction of skirting & finished surface of wall etc complete.
SFT -
5.08 Decorative tiles Providing & Fixing of Decorative tiles for flooringEXECUTIVE
LUNCH ROOMSFT 425
6.00SKIRTING &
TRIMS
6.01ITALIAN MARBLE
SKIRTING
Providing and fixing of italiam marble on tread and riser of max 300 mm wide and ,mode of measurement will be
separate for riser and treadRECEPTION AREA RFT 150
6.01GRANITE
SKIRTINGSame as above but in granite finish BREAKOUT AREA RFT -
6.02 KOTA SKIRTING
Providing and cladding 100 mm high Kota Stone for Skirting of approved make and approved sample in pattern as
per detailed drawings. The Skirting shall be fixed in 12 mm thk. bed of C.M 1:3. . The rate should be inclusive of
cleaning joints and grouting them with neat white cement paste with pigmented additives to match shade of the tile
Skirting to be fixed flush with finished surface of wall in line & level and 6 mm wide groove to be made in wall at the
junction of skirting & finished surface of wall etc. complete.
ELECTRICAL ROOM RFT 45
6.03
VITRIFIED TILE
50MM THK
SKIRTING
Providing and cladding 50 mm high vitrified tile of approved make and sample for skirting in pattern as per detailed
drawings in cement paste on a backing coat of cement mortar in ratio of 1 : 3. The rate should be inclusive of cleaning
joints and grouting them with neat white cement paste with pigmented additives to match shade of the tile. Skirting to
be fixed flush with finished surface of wall in line and level and 6 mm wide groove to be made in wall at the junction of
skirting and finished surface of wall etc. complete matching to flooring.
EXECU- PANTRY AREA RFT 60
7.00 COUNTERS
7.01PANTRY
COUNTER
Providing and constructing counters 600 mm wide and 800 mm high fabricated from granite top based fixed on
kadappa on cement mortars.Moulding, beading/lipping, edge and corner molding etc. all complete with cutout in the
slab for fixing the Tap / basin / sink (Basic cost of Granite : Rs. 180 /- sq.ft)
PANTRY COUNTERS RFT 12
CIVIL & INTERIOR WORK
8.00 FALSE CEILING
8.01GYPSUM FALSE
CEILING
Providing and fixing Gypsum False Ceiling of Gypsum which includes G.I. Perimeter Channels of size 0.55 mm thick
( having One Flange of 20 mm. and another flange of 30 mm and a web of 27 mm ) along with perimeter of ceiling,
screw fixed to brick wall / partition with the help of Nylon sleeves and screws at 610 mm centers. Then suspending
G.I. intermediate channels of size 45 mm ( 0.9 mm thick with 2 flanges of 15 mm each ) from the soffit at 1220 mm
centers with ceiling angle of width 25 mm X 10 mm X 0.55 mm thick fixed to soffit with G.I. cleat and steel expansion
fasteners. Ceiling section of 0.55 mm thick having knurled web of 51.5 mm and 2 flanges of 26 mm each with lips of
10.5 mm are then fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to
the intermediate channel at 450 mm centers.rate including of cutout of gypsum for services
OVER ALL STAFF AREA SFT 5,400
8.02COVE GYPSUM
CEILING FACIA
Providing and Fixing Gypsum board cove ceiling as per detail drawing and direction of the architects. With provision
and cutouts for fixing light fittings, cable, conduits etc. running internally, AC grill fixing etc.OVER ALL STAFF AREA RFT 500
8.03GYPSUM 2"-6"
FACIA
Providing and Fixing Gypsum board cove ceiling as per detail drawing and direction of the architects. With provision
and cutouts for fixing light fittings, cable, conduits etc. running internally, AC grill fixing etc same as above but 2'-6"
high
RFT -
8.04LAMINATE FINISH
CEILING
Providing and fixing wooden ceiling with framework in 50mm x 35mm approved seasoned hardwood section @
600mm c/c both ways suspended from RCC slab. Panels consisting of 12mm thick plywood finished with 1mm thik
Laminate of approved shade and sample as per drawings. The panels to be finished in approved melamine polish
with grooves as shown in the drawings.
SFT 100
PARTITION
8.07GYPSUM
PARTITION P/G Gypsum partition on g.i.frame with 12.5mm thk.gyp board on both side ENCLOSED AREA SFT 2,850
8.08GLASS WOOL
INSULATION
Providing and filling Rock wool insulation of density 48 kg per cum, of TWEGA make ( 600 X 600 ) size of thickness
40 mm as per manufacturer's specificationsENCLOSED AREA SFT 2,500
8.09ABOVE CEILING
PARTITION
Providing and fixing full height framework with seasoned salwood grid frame work of finished size 2" X 1-1/2" @ max
2'-0" c/c, Every vertical member would extend upto & be anchored to the true ceilingThe skinning shall be of 12 mm
thk commercial ply on both side finished with 1mm thk laminate as per approved sample screwed to the erected
fra.The rate shall include providing additional supports, bracing wherever needed as per the design & making of
sleives/ cutouts wherever required and including of all necessary hardware, scaffolding etc. complete as per
instruction & design of the architect.
ENCLOSED AREA SFT 800
9.00PANELING &
BOXING
9.01LAMINATE
PANELING
Providing and Fixing paneling made out of 19 mm thk commercial ply framework @ 600 mm c/c distance cladded
with 12 mm thk commercial ply finished with 1st quality of approved shade, color of 1.0 mm thk laminate etc. all
complete as per detailed drawing given by the Architect. (Basic Rate of Laminate is Rs 35 per Sft. )
COLUMN PANELING SFT 300
9.02VENEER
PANELING
Providing and Fixing cladding made out 1" X 1" thk sal wood frame work wherever applicable cladded in 12 mm thk
commercial ply & finished in 4 mm thk approved shade of veneer finished with Melamine polished as per detailed
drawing given by the Architect. Basic (Basic Rate of Veneer is Rs 75 per Sft. )
BOARD ROOM &
CONFERENCE ROOMSFT 120
9.03PROJECT
SCREEN PELMET
Providing and fixing pelmets to house projection screen made of 19mm thick commercial plywood of approved make,
having clear internal dimensions as 150 x 200mm, finished in approved shade laminate, supported from RCC ceiling
slab by necessary framework.OPEN OFFICE AREA RFT 20
9.04 PELMET
Providing and fixing pelmets of size 150 mm x 200 mm, or as per site conditions with verticals made of 19 mm thk ply
and horizontal in 19 mm thk ply along the walls and partitions with necessary Salwood support upto 1mtr, joint
between the Ply pelmet & the gypsum to be cladded with L-section 75 mm X 10 mm Aluminum angle finished in
white powder coating as per detail complete. The rate to be inclusive of all accessories required for fixing pelmets
complete.
GLAZING AREA RFT 135
9.05
COLOURED
GLASS
PANELING
p/f Back painted Glass 6mm thk. For writing board in meeting Room & CabinsENCLOSED MEETING &
COLOMN AREASFT 600
9.06
RAW BOXING
WITH FRAME
WORK AND PLY
FIXING
Providing & Fixing of 6 mm ply skining With Necessary Wooden Support / Aluminium Support as per directed ENCLOSED MEETING &
COLOMN AREASFT 600
9.07BRICK PATTERN
TEXTUREProviding and fixing of brick pattern texture as per design approved by Architect SFT -
9.08CEMENT SHEET
PANELING
Providing and fixing of 12mm thk. Cement sheet panel as per selection Complete with All necessary Support as per
directed. SFT 100
9.09MDF PANELLING
FOR RECEPTION
Providing & Fixing of Mdf panelling design Hexgon pattern for Reception area with Necessary Support required for
the same.RECEPTION AREA SFT 120
9.10TINTED GLASS
PANELLING Providing & Fixing of Tinted Glass panelling for Reception area as per approved shade by architect SFT 100
10.00 SHUTTERS
10.01DB BOXING &
SHUTTER
Providing and fixing DB shutters in 25 mm thick Block board finished in 1.0mm thk approved shade laminate
externally with 12 mm thk teak wood beading and ply framework of19 mm, inside face of shutter to be finished in
approved shade .08mm thk laminate inclusive of providing & fixing of Aluminum Perforated Grill of size 450 mm x 225
mm or as per the Architect finished in approved shade powder coating for ventilation, approved handle, 225 mm tower
bolts, Locks, etc complete as directed.
FOR DB AREA SFT 175
10.02TRAP DOOR IN
PLY
Providing and fixing Trap door in the false ceiling for HVAC in 19mm thick plywood finished in approved laminate on
the exposed side and exposed side of shutter in approved shade laminate and other in balancing laminate, inclusive
of 19mm thk marine plywoodOFFICE AREA SFT 550
11.00 DOOR
11.01SOLID DOOR (
OPEN DOOR Same as above but 35mm thk.size 750 X 2400 ( both side Laminate with OPEN DOOR CLOSER TOILET DOORS Nos 3
11.02VISION PANEL
DOOR
Providing and fixing 35 mm Commercial flush door with approved shade of Laminate as mentioned in below on both
side or otherwise specified, with 10mm thk. Clear Glass vision panel of required size as per design, with Concealed
Door Clouser
CUT OF LOBBY, PANTRY
EXECUTIVE, STORE ROOM
& CXO SEC CABINS
Nos 4
11.03 DOOR FRAME
Providing and fixing Salwood frame for doors of approximate size 100mm X 75mm as approved by Architect. The
Junction of wall / partition to be covered by Architrave/ molding as approved by the architect or any other option as
proposed by the architect
CUT OF LOBBY Nos 1
11.04LAMINATE SHAFT
SHUTTER DOORlaminating finished of shaft door with frame 1200mm
STORAGE DOOR NEAR
CONFERENCE ROOM Nos 1
12.00LOOSE
FURNITURE
12.01 SOFT BOARDProviding and fixing Fabric wrapped soft board panels 12mm thick of size and profile as per detail i. The rate should
include approved fabric (basic price Rs. 250/rmt), as per approved specification with necessary hardware.ALL CABIN AREAS SFT 230
12.02RECEPTION
TABLE
Providing and Fixing Reception Table for as per Detail Drgs. Of size 3500mm X 800mm deep & 1050mm ht finish in
Laminate & Corian including pedestal unit RECEPTION AREA Nos 1
12.03RUNNING
COUNTER
Providing and constructing running counter of 600mm wide, as described below, work top in 19mm thick ply with
edge finished in approved laminate. The underside of the table to be prefinished in approved balancing laminate. HT
750MM
RFT -
12.04 Library UnitProviding and Fixing Of Library Unit with 19mm thick ply and 6mm ply at back complete with all hardware and labor
as per design and as instructed by architect
BREAKOUT AREA &
LIBRARY AREASFT 200
13.00 STORAGES
13.01FULL HT
LAMINATE FINISH
STORAGE
p/f full/Low height laminate finish storage from inside n outside deep 450mm STORE ROOM STORAGE SFT 40
13.02COUNTER
BELOW SHUTTER
Providing and constructing shutter below counter of basin size as per drawings, with19mm thick marine grade
plywood, back in 8mm thick marine ply, intermediate in 19mm thick marine grade plywood,PANTRY AREA SFT 60
13.03OVERHEAD
STORAGE
Providing and constructing overhead storage of width 450mm and size as per drawings, with top, sides and bottom in
19mm thick commercial grade plywood, back in 8mm thick commercial ply, intermediate in 19mm thick commercial
grade plywood.PANTRY AREA SFT 40
13.04 AV STORAGES
Providing and constructing AV storages as per detailed drawings. finished in Laminate. All exposed edges to be
finished in approved T.W binding finished in approved melamine polish. Rate to include hardware such as approved
locks, auto closing hinges for s
BOARD ROOM &
CONFERENCE ROOMSFT 50
13.05JANITORE
STORAGEp/f janitor storage in Marine ply finish in laminate from inside & outside TOILET AREA SFT 40
14.00 PAINTING WORK
14.01
PLASTIC
ACRYLIC
EMULSION
Providing and applying three coats of Plastic emulsion paint of Asian / ICI / Berger make to all internal walls / ceilings,
of approved color over a coat of water based primer including preparation of surface by thorough cleaning and wetting
and applying ready made putty of "Altek" or "Wall Care" or equivalent as per manufacturer specification fully to give a
smooth and even surface before painting and curing as per manufacturers specifications and as directed.
OFFICE AREA SFT 9,500
14.02GREY COLOR
PAINT FOR p/a 3 coat of dust free paint on open ceiling area OFFICE AREA SFT 1,000
14.03 TEXTURE PAINT
Providing and applying two coats pigmented surface texture of desired shade at all heights to give an even and
uniform shade as per manufacturers specification from approved make or its equivalent. Rate shall include
preparation of base surface, watering
SFT 560
14.04LUSTER (
ENAMEL PAINT )
Providing and applying three coats of Luster paint of desired shade, of Asian / Berger / ICI paints or equivalent on
internal wall surfaces wherever required at all heights to give an even and uniform shade, applied over a coat of primer
and putty "Altek" or "Wall care" or approved equivalent as per manufacturer specification fully to give a smooth and
even surface including thoroughly brushing the surface free from water / mortar dropping and other foreign matter
and sand papered smooth, complete per manufacturers specifications and as directed.
OFFICE AREA SFT 7,850
14.05OPEN DUCT
PAINTINGOil base paint for ducting DUCT PAINT Job 1
15.00MISCELLANIOUS
WORK
15.01
PLANTER
BOXING
FINISHED IN
As per design Minimum ht of 300mm vertical Panelling and 180 mm wide top BEAKOUT AREA SFT 50
15.02HOUSE KEEPING
CHARGES
Providing unskilled man power for General house keeping works at all floors during construction work including all
required tool and tackles.FULL OFFICE AREA SFT 10,100
15.03 KEY HIVES p/f Glass with Glass shutter finish in laminate with " J" Hook Nos 1
Nos ITEM SPECIFICATION LOCATION UNIT QTY RATE AMOUNT
1.01OPEN CELL
CEILING
Providing and fixing in true horizontal level Open cell Aluminium lay-in ceiling tiles with border panels forming flush-
tegular/board edge of size 600mmx600mmx35mm having Humidity Resistance of 99% RH, and having Fire
Performance CLASS 0/Class 1 (BS 476). The tile of ‘global white’ colour with cell size of 200mm.
The grid should be of approved make with 15mm wide T - section flanges colour white having rotary stitching on all T
sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying
capacity of 14.0 Kgs/M2. The T Sections have a Galvanizing of 90 grams per M2.
The Tile & Grid system used together should carry a 10 year warrantee.
(ONLY PLAN AREA CONSIDERED FOR MEASUREMENTS)
SFT -
1.02 BAFFLE CEILING
Supply and Installation of METAL Linear Baffle suspended ceiling of approved make. Panel size 100mm deep x
25mm width using 0.7mm thick, panel length as per architect requirement, coil coated on a continuous paint line,
anchor fastner height atleast 100 mm
RECEPTION & BREAKOUT
AREASFT 200
1.03SLOTTED ANGLE
RACKSHUB ROOM SFT 100
1.04 COMPACTORS SFT -
2.00 FLOORING
2.01
ACCESS
FLOORING -HPL
PANELS-300 MM
HIGH
Providing & fixing stringer based raised access floor of approved make metal cladded system finished in Anti-Static
laminate of approved shade consisting of : Panel Construction: Panels of size 600 mm X 600 mm are manufactured
from pressed form corrosion resistant galvanized steel. The above hollow panel shall have an infill of light weight
cementatious material. The entire panel shall be coated with epoxy coating on the exposed surface. Pedestal
construction shall be all steel construction, zinc plated and consisting of anti vibration head cap with cruciform up
stands and four panel locating studs, positively clipped to the steel top plate . Pedestal shall be screwed to floor.
Uniformly distributed load shall be 12 kN/m2 Concentrate point load : 4.0 kN over 25 sqmm. Floor void should be 300
mm minimum from underside of raised floor pan to finish slab. Provision should made for satisfactory earthing for all
floor tiles. ( Height-300mm)
SERVER ROOM SFT 115
2.02
ACCESS
FLOORING -BARE
PANELS-450MM
HIGH
Providing & fixing stringer of access floor but the panels shall be BARE with out STRINGER and the overall height of
the raised floor system shall be 450 mm : Panel Construction: Panels of size 600 mm X 600 mm are manufactured
from pressed form corrosion resistant galvanized steel.
SFT -
2.03WOODEN
FLOORINGProviding & fixing Laminated Flooring with all required accessories complete LIBRARY ROOM SFT 435
3.00 TOILET CUBICLE
3.01 TOILT CUBICLEStandard toilet modular partitions – floor anchored. Impervious to moisture, rust proof, power washable. Matrix /
Innerspacec TOILET AREA NOS 6
4.00SKIRTING &
TRIMS
4.01GLASS
PARTITIONProviding and fixing 10 mm thick toughened glass full height Glass Partition with aluminium frame of size 28x25 mm FOR ENCLOSED AREA SFT 2,500
4.02
ALLUMINIUM
PROFILE
SKIRTING 50MM
HT
Providing and fixing Aluminum skirting of 50 mm of approved make with rubber beading fixed on screwing slot on
partitions and walls etc. all complete as per architects instructions. The rate to be inclusive of all accessories required
for fixing of skirting complete. OVER ALL OFFICE AREA RFT 1,000
4.03 DOUBLE DOOR Suupply & Installation of Toughened Glass Door with patch fitting
( Size :1500mm X 2400mm ) ENTRANCE DOOR Nos 1
4.00 DOORS
4.04 GLASS DOOR Suupply & Installation of Toughened Glass Door with patch fitting
a ( Size :1200mm X 2400mm )ENT. DOOR FROM
CONFERENCE ROOM SIDENos 1
b ( Size :900mm X 2400mm ) ENCLOSED AREA DOORS Nos 25
4.05MODULAR
ALLUMINIUM Providing & Fixing of Aluminum door frame CRITICAL AREAS Nos 26
4.06Door stopper for
Glass DoorsNos 27
5.00 FALSE CEILING
5.01
MODULAR
MINERAL FIBER
CEILING
(600x600)
Providing and fixing modular ceiling systems WITH SELECT GRID with mineral fiber board ceiling tiles as per
following specifications. Rate to include all fastening accessories with approved finishes. Ceiling tiles shall be
approved make regular edge tiles ( Armstrong/AMF /USG make ), of size 600 mm x 600 mm of approved color. Tile
shall render a NRC level of ( 0.6 ). Suspension system shall be manufacturer specific stitched (Turlock or any other if
known ) Installation to comprise of main runners spaced at 1200 mm centers securely fixed to the structural soffit by
approved hangers at 1200 mm maximum centers & not more than 150 mm from spliced joints. The last hanger at the
end of each main runner should not be greater than 600 mm from the adjacent wall. 0.7 NRC. anchor fastner height
atleast 100 mm
STAFF SEATING ABOVE SFT 2,800
5.02 METAL CEILING
Providing and fixing modular metal ceiling systems with metal tiles as per following specifications. Rate to include all
fastening accessories with approved finishes. Ceiling tiles shall be approved make regular edge tiles ( Armstrong /
Ecophone / AMF make ), of size 600 mm x 600 mm of approved color. Suspension system shall be manufacturer
specific stitched ( Turlock or any other if known ) Select grid system . Installation to comprise of main runners spaced
at 1200 mm centers securely fixed to the structural soffit by approved hangers at 1200 mm maximum centers & not
more than 150 mm from spliced joints. The last hanger at the end of each main runner should not be greater than
600 mm from the adjacent wall.
TOILET AREA SFT 250
5.03 Axiom 100mm high Axiom RFt -
6.00SLIDING
FOLDING
6.01SLIDING &
FLODING Providing & Fixing of Sliding & folding partition in traning rooms in fabric finish SFT -
7.00FIRE RATED
DOOR
7.01METAL FIRE
RATED DOOR
SINGLE LEAF
P/F of 2 Hrs Fire rated door for server room finish in laminate single leaf ( 900 X 2400mm)UPS & SERVER ROOM
AREANos 2
8.00MISCELLANIUOS
WORK
8.01 ROLLER BLINDSSupply and Installation of Roller Blinds with head channel, traversing cord, and warranty etc. as per manufacturer's
specifications. Fabric to be as per approved sample.GLAZING SIDE ONLY SFT 945
9.00 FROSTED FILM
9.01FROSTED FILM
ON GLASSSupply & Installation of Frosted / Dusted effect, Self-adhesive, bubble-free installation to be done on clean glass. SFT 1,300
9.02DECORATIVE
FILMSupply of Decorative Flims
INTERNAL PARTITION
AREA ONLYSFT
10.00WALL PAPER &
GRAPHICS
10.01 WALL PAPER Supplying and fixing of wall paper (Basic cost - Rs. 70 sq.ft) OVER ALL AREA SFT 650
10.02 GRAPHICS Supplying and fixing of Decorative Graphics/ ARTWORK AS PER DESIGN OVER ALL AREA SFT 700
11.00 SIGNAGES
11.01NAME PLATES
FOR WORK P/f of acrelique name plate for workstations Nos -
11.02PUSH / PULL
SIGNAGEPush/Pull ( 3" x 3") in S.S PLATE AS PER DOORS Nos 40
11.03ROOM
IDENTIFICATIONRoom Identification / General (6" x 6") IN S.S plate AS PER CABINS Nos 30
11.04FIRE EXIT
SIGNAGEFire exit signage's ( self glowing letters- 1'-3" x 6" ) in acrylic board OVER ALL OFFICE AREA Nos 12
11.05MAIN LOGO FOR
RECEPTIONMain Logo for Reception area RECEPTION AREA Nos 1
11.06FIRE
EVACUATION Fire Evacuation Plan ( Size of 18" x 12") -Steel finish with self engraved ,in acrylic board OVER ALL OFFICE AREA Nos 4
TOTAL -
INTERIOR SUPPLY ITEM
DEVELOPER SCOPE OF WORK
1.00CEMENT
PLASTER
Providing internal cement plaster of 12 mm -15 mm thick in a single coat of cement sand mortar in a ratio of 1 : 4 to
concrete and masonry surfaces in all positions including of hacking of RCC/ wall surfaces, preparing surface before
applying plaster, proper curing, scaffolding, etc. complete. The rate to be inclusive of providing and fixing GI chicken
mesh at the junction of RCC and masonry works with nails, etc. scrapping of surface for plastering.
EXISTING WALLS SFT 4,000
2.00
DEMOLISHING
OF EXISTING
FLOORING
Demolishing of Existing FLOORING PASSAGEAS PER RACEWAY
REQUIREMENTSFT 8,000
3.00DEMOLISHING
OF BBCDemolistion of existing BBC ( 400 mm deep) ONLY IN TOILET AREA SFT 300
TOTAL -
Nos. ITEM DESCRIPTION OF ITEMS UNIT QTY RATE AMOUNT
A CIVIL WORK
1.00 Vitrified Tiles ( 600 x 600 mm)
Providing and fixing Vitrified tiles ( Antiskid) for Flooring as per approved design with vitrified tiles of approved
colour & make fixed with 1:4 cement mortar, including providing & laying 12mm thk plaster bed in , fixed with neat
cement slurry joined with matching. ( Basic cost of vitrified tiles flooring 55/- per sft )
SFT 225
2.00 Vitrified Tiles ( 600 x 600 mm) DADO
Providing and fixing Vitrified tiles for Dado as per approved design with vitrified tiles of approved colour & make fixed
with 1:4 cement mortar, including providing & laying 12mm thk plaster bed in , fixed with neat cement slurry joined
with matching. ( Basic cost of vitrified tiles flooring 55/- per sft )
SFT 900
3.00 Vitrified Tiles ( 600 x 600 mm)
Providing and fixing Vitrified tiles ( Antiskid) for Flooring as per approved design with vitrified tiles of approved
colour & make fixed with 1:4 cement mortar, including providing & laying 12mm thk plaster bed in , fixed with neat
cement slurry joined with matching. ( Basic cost of vitrified tiles flooring 80/- per sft )
SFT 70
4.00 dado Same as above but on wall dado SFT 280
5.00 Grouting RFT 650
6.00 Brick Bat Coba
Providing & laying brick bat coba with Cement concrete (1:2:4), with P & L cement based water proofing as per M/s
India Water proofing Co.'s specifications / Roffe chemical over concrete slab flooring with 10 year guarantee
including screedingcuring etc. the level as specified in the drawing or instructed by the architect. ( Avg Ht-200mm
ht)
SFT 295
7.00 Siporex Filing up to 450 mm
Providing & laying Siporex Filing up to 450 mm with Cement concrete (1:2:4), with P & L cement based water
proofing as per M/s India Water proofing Co.'s specifications / Roffe chemical over concrete slab flooring with 10
year guarantee including screedingcuring etc. the level as specified in the drawing or instructed by the architect
SFT 0
8.00 Water Proofing
Providing waterproofing treatment to floors and walls , by cleaning the surface, identifying and filling the cracks by a
paste of cement and waterproofing compound as manufactured by ROFF / Fosroc or equivalent make as per the
manufacturer’s specifications then applying cement slurry along with waterproofing compound all over the surface
before laying brick bats in one layer sandwiched between two layers of 20 mm thick in cement mortar 1:4 along with
approved waterproofing compound from ROFF / Fosroc equivalent make as per the manufacturer’s specifications
and finishing smooth with jute fibers mixed at the rate of 0.9 kg per cement bag in necessary slope including finishing
with 300 mm height of wall in cement mortar 1:4 with waterproofing compound and curing the same by preparing
watta for 14 days complete all carrying a guarantee of 5 years.
SFT 500
9.00 Granite JambP & F straight edge granite slab for jamb & Sill lining upto 9" wide ( or as per site requirement) as instructed,
complete with level, polish, edge polish etc.) RFT 36
10.00 Granite Threshold
Providing and fixing thresholds of 19mm thick polished granite slab of approved shade fixed along the doors (it shall
be provided flush with finished edges of the wall) on 1:4 cement mortar, as per detailed design and as directed and
shall be provided flush with adjoining flooring levels.
RFT 10
11.00 Granite Window FrameP & F straight edge granite slab for window frame lining upto 9" wide ( or as per site requirement) as instructed,
complete with level, polish,edge polish etc.) RFT 0
12.00 Hand wash Counter ( Granite)Providing and fixing of Granite Finish counter with 19mm thk marine ply finish Granite of approved color and shade
and with ply boxing below as per design and directed by the architect.RFT 16
14.00 Urinal Divider Providing & fixing Corian Finish Urinal Divider 1'-6"' wide with nessacry support NOS 3
B PLUMBING & FIXTURE
1.00 Internal Plumbing
Internal Concealed plumbing work for Providing & Laying CPVC & PVC pipe for plumbing all fittings, including
injection molded fittings where required e.g. tees, bends, solvent , couplings and adapters , connection brass make
and jointing with adhesive approved by fittings manufactures including necessary MS clamps thick flat, cutting
chases holes in brick
Internal Concealed plumbing work for Gents Toilet Lumsum 1
Internal Concealed plumbing work for Ladies Toilet Lumsum 1
Internal Concealed plumbing work for Executive Toilet NOS 1
Internal Concealed plumbing work for Café handwash - (BASIN- 3) NOS 0
Internal Concealed plumbing work for Cafeteria Pantry NOS 1
2.00 Sanitary Fixture
Supply & Fixing of Wash Basin . NOS 5
Supply of W.C . NOS 6
Urinals. NOS 4
Two Way bib cock with spray NOS 6
Tissue paper dispenser NOS 6
Soap Dispenser & Holder with frosted glass bottle in polished Chrome- NOS 3
Plastic Tissue paper dispenser (ASKON / KIMBERLY CLARK make) NOS 3
Hand Dryer (single blower with FRP cover) (make:- Askon) NOS 3
Pillar Cock- Singulier Tail Pillar Cock NOS 5
S / P TRAP FOR BASINS AND URINALS NOS 9
Angle Valve G 1/2" in Polished Chrome NOS 7
Concealed in-line Stop Valve G1/2" connection in polished Chrome NOS 3
Floor traps cockroach proof chilly make NOS 10
Urinal Sensors. NOS 4
Sink cock NOS 5
Flush valve for WC NOS 6
handicap set NOS 0
3.00 Mirror panelling Providing and fixing 50 mm thick Marine ply boxing with 6mm thk.clear Mirror on it SFT 55
TOTAL -
TOILET WORK
Sr. No. ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.00 LINEAR WORK STATION
Providing & Fixing of Linear workstation with 25mm pvc edge banded top.Desking system with Conical legs at
open passage ends and 50 by 50 MS square intermediate legs recessed between tops Frameless SB Fabric
screen above top of 350mm ht.Single cable carrier below top with internal 50mm high separator for data and
electricals Modesty panel below tops : 300mm high from the floor Prelam Flap with brush Vertical MS box for
cables to rise from floor as required. ( Size : 1200 mm X 600 mm ). Cost is including With Pedestal & Key
board Tray
NOS 61
2.00LINEAR WORK STATION
WITHOUT PARTITON
Providing & Fixing of Linear workstation with 25mm pvc edge banded top.Conical legs at open passage ends
and 50 by 50 MS square below top with internal 50mm high separator for data and electricals Modesty panel
below tops : 300mm high from the floor Prelam Flap with brush Vertical MS box for cables to rise from floor as
required. ( Size : 1050 mm X 600 mm ). Cost is including With Pedestal & Key board Tray
NOS 7
3.00 SVP CABIN & CXO SECY TABLE
Providing & Fixing of Linear Cabin Table Top & side finish in veneer with laminate finish appron & Side
creadenza with top in veneer & shutter in laminate the provision one openable shutter & 3drawer . Table
provision with openable Flap .( Size of Table 1650 x 600 x750 & Side creadenza Size of 1200 x 450 x700
mm )
NOS 6
4.00 VP CUBICLE
Providing & Fixing of Linear Cabin Table With powder coated Apron & M.s legs provision & Side creadenza
with the provision one openable shutter & 3drawer . Table provision with openable Flap . Size of Table 1600
x 600 x 750 & Side creadenza Size of 900 x 450 x 700 mm .
NOS 4
5.00 CXO & CEO CABIN TABLE
Providing & Fixing of Linear Cabin Table Top & side finish in veneer with laminate finish appron & Side
creadenza with top in veneer & shutter in laminate the provision one openable shutter & 3drawer . Table
provision with openable Flap .( Size of Table 2100 x 750 & Side creadenza Size of 1600 x450 x 700 mm )
NOS 11
6.00 MD CABIN TABLE
Providing & Fixing of Linear Cabin Table Top & side finish in veneer & Side creadenza with top & shutter
finish in veneer the provision one openable shutter & 3drawer . Table provision with openable Flap .( Size of
Table 2400 x 8000 & Side creadenza Size of 1600 x450 x 700 mm )
Nos. 1
7.00 STORAGE ( CABIN)Providing & Fixing storage of ht 700mm with veneer fiish top & shutter & inside storage finish in laminate with
all nessary hardware & locksSQFT 280
8.00 MEETING TABLE
Providing & Fixing of Table top of 25 mm thk. VENEER finish table top with edge banding & Provision of Pop
up box as per Product selection . Table should have the provision of Openable shutter for services for wire
manager . ( Size of Table - 3000 x 1050)
Nos. 1
9.00 4PAX MEETING TABLE
Providing & Fixing of Round Table top: 25mm thick PLPB table top with matching edgebanding & Aluminum
Flipup provision.Size: 450mm(W)x120mm(D).. Understructure: 45Dia Slanted legs (Q33 Model - Standared
color is white) considerd for supporting table top. Wire management: MS-Powder coated wire tray Vertical duct
considerd for cable management. Meeting Table Specifications ( Size of 1200 MM Dia )
Nos. 2
10.00 STORAGE Provding & Fixing of 400 deep Storage as per directed Sq..ft 100
11.00 EXECUTIVE LUNCH TABLEP/f Executive Lunch table finish in 50mm thk.top finish in Corian & M.s. Powder coated leags supports ( size-
5400 X 900 X 1050 )Nos 1
TOTAL OF MODULAR 0
MODULAR FURNITURE
S.NO. PARTICULARS DESCRIPTION UNITS TOTAL RATE AMOUNT
1.00 MID BACK CHAIR
Q-Mesh Mid Back - with 5 Prongs Crome base, Twin wheel nylon castors,
syncro single point locking mechanism, fixed T arms, Nylon mesh on the
back with front & Back moving adjustable lumber support, gas lift moulded
Seat with Injected PU foam.
Nos 91
2.00 HIGH BACK CHAIR
Q-HIGH Back chairs -With Head rest & with 5 Prongs Crome base, Twin
wheel nylon castors, syncro single point locking mechanism, fixed T arms,
Nylon mesh on the back with front & Back moving adjustable lumber
support, gas lift moulded Seat with Injected PU foam.
Nos 9
3.00 HIGH BACK CHAIRS
High Back Mesh Back ,Cushion Headrest & KT Mechanism Fixed Armrest
Gaslift for seat height adjustment standard 5-prong Nylon Base, Fixed
Handle Nos 10
4.00MEDIUM BACK CHAIRS
Mid Back Synchronized Mechanism with Multiple Locking Adjustable
Armrest with Leather Padding Gaslift for Seat height adjustment Standard 5-
prong Nylon Base Nos 30
3 MD & CFO ChairSONOMA - LEATHER FINISH (HIGH BACK)
Nos 2
4 MD & CFO visitor ChairSONOMA - LEATHERITE FINISH (MEDIUM BACK)
Nos 5
5.00 HIGH BACK CHAIRS
High Back Mesh Back ,Cushion Headrest & KT Mechanism Fixed Armrest
Gaslift for seat height adjustment standard 5-prong Nylon Base, Fixed
Handle Nos 28
2.00 SINGLE SEATER SOFA CHAIRS SoFA Chairs Nos 2
3.00 BREAK OUT CHAIRS Providing of Breakout Chair as per approved shade by the architect. Nos 12
4.00 POUFFEESProviding of Pouffee for breakout area made in core / fiber / foam finished
with leatherite as per design approved by the architect.Nos 8
5.00 L SHAPE AREA Nos. 2
6.00 CAFETERIA CHAIRSProviding & Fixing of Café Chair finished in Nylon as approved by the
architect with MS Powder coated legs.Nos 0
7.00 MEDIA SCAPE CHAIRProviding of Media Chair for media scape table as per approved shade by
the architect.Nos 16
9.00 CENTER TABLE FOR MD CABIN & DY CEO AREA Providing of Center Table as approved by the architect. Nos 2
TOTAL FOR CHAIR & SOFA 0
CHAIR & SOFA
S.NO ITEM SPECIFICATION UNIT TOTAL RATE AMOUNT
1 Tile Carpet flooring Supply & Installation 18 to 20 oz. tile carpet formed flooring of Approved
make and of approved shade as per manufacture specification in Nylon
Construction: Tufted / Textured / Graphic Loop Pile
Tufting Guage: 1/12
Usage Type: Medium- Heavy duty for Commercial applications.
Yarn System: 100% Nylon 6,Nylon 6.6, Nylon Antron.
Dye Method: Solution Dyed / Printed
Pile Weight: 20 TO 24 oz per yard
Pile Height: 9.0mm
Sustainability: Low VOC. CRI Certified.
Radiant Panel: ASTM E 648 / CLASS I
Primary Backing:
Must be non-woven. Woven primary backings not allowed.Backing material
to be Environment friendly, Recyclable, PVC Free, with high recycled
content.
Secondary Backing:
Fiberglass Reinforced Thermoplastic Composite containing not less than
39% post consumer and/or post industrial material content. Secondary
backing must be 100% recyclable at the end of its useful life. Certification is
required for recycle content.
Atic StockThe rate should include 3% of attic stock to be handed over to the client at
the completion of the project with properly covered.
Soil Stain Protection: Approved Stain Protection / Soil guard treatment.
Antimicrobial:
(AATCC 171 Washed) (AATCC 174 Parts 2&3). Must pass both Part 2 and
Part 3 of AATCC 174 with a minimum of 90% reduction both gram negative
and gram positive bacteria and no macroscopic growth against the fungi.
Anti-Static properties as per manufacturer's specs
Size 600 x 600 mm. (or as per manufacturer)
Carpet cover & maintenance
The rate shall include covering of the laid carpet with 1mm. Thk plastic
sheets, with proper taping of the joints.The onus of maintaining the carpet
dust , stain & damage free would be solely on the vendor. The rate shall
include whatever necessary for doing so.
ShampooingThe rate shall include shampooing of the carpet prior to handover as per
instruction & satisfaction of the architect.
Quantity Certification
The quantity mentioned in the BOQ is the approximate laid quantity and
hence the vendor needs to take the exact quantity as per the auto-cad
drawing shared .
Actual quantities will be certified as per carpet laid on the site. Wastage
must be factored in the cost.
Guarantee/Warranty At least 10 years
cost include with plastic protection
1 Tile Carpet flooring TYPE -01 Sq.Ft. 4500
colour carpet Sq.Ft. 3500
TOTAL FOR CARPET FLOORING 0
CARPET FLOORING
Nos ITEM SPECIFICATION UNIT QNTY RATE AMOUNT
1.00 PEST CONTROL
1.01 PEST CONTROL
Providing Pest control and Anti-termite treatment by appointing a specialized agency as per
the specifications mentioned by the Bureau of Indian Standards and Agencies specifications
(whichever is higher), for General Civil, Plumbing/ Drainage and timber/ Carpentry works,
Gypsum related work, including a 5-year guarantee under suitable undertaking on stamp
paper etc., complete as directed. ( Mode of measurement to be on carpet-area of floor and
not the area of surface treated.)
S.Ft. 1,700
2.00 DEMOLISHING
2.02 REMOVING OF DEBRIS Disposal of Debris from site to an identified location by client Nos 2
3.00 MASONARY WORK
3.01AERATED LIGHT WEIGHT WALL
OF 100 MM
Providing and constructing Aerated light weight bock masonry wall of 100 mm thick ( Block
size ) in cement and sand mortar in a ratio of 1 : 4 including M-15 Reinforced concrete lintels
of 100 x 100 mm size with 4 Nos. 6 mm rods and 6 mm stirrups @ 600 mm c/c at an equal
vertical distance of 1200 mm, raking out joints, curing, scaffolding, cleaning, etc.
S.Ft. 320
3.03 SIPOREX FILLING 450MM P/F Siporex filling upto 450mm high S.Ft. 350
3.02 PCC
Providing and laying up to 100mm thick cement concrete flooring with cement, sand and
aggregate properly mixed in a ratio of 1 : 2 : 4 or 1 : 21/2 : 31/2. The Cement concrete laid to
proper level and slope in alternate bays including compactions, filling of joints or as directed,
etc. complete as per architects instructions. Finished in Smooth cement Mortar 1:1 of
sufficient minimum thickness to give a smooth & even surface and curing etc. complete as
per architects instructions. Cost should be inclusive of hacking the floor so that IPS Adhere to
the existing floor The cost shall inclusive the preparation of the surface rough by chiseling etc
for adhering the PCC.
S.Ft. 1,400
4.00 WALL PREPARATION
4.01 CEMENT PLASTER
Providing internal cement plaster of 12 mm -15 mm thick in a single coat of cement sand
mortar in a ratio of 1 : 4 to concrete and masonry surfaces in all positions including of hacking
of RCC/ wall surfaces, preparing surface before applying plaster, proper curing, scaffolding,
etc. complete. The rate to be inclusive of providing and fixing GI chicken mesh at the junction
of RCC and masonry works with nails, etc. scrapping of surface for plastering.
S.Ft. 400
5.00 FLOORING & CLADDING
5.01 Flamed Granite flooring P/f Flamed Granite flooring ( basic rates of granite-180Rs/sqft) S.Ft. 1,200
5.02 Laminated flooring p/f laminated flooring S.Ft. -
5.03 Wall cladding p/f Shera Board wall claddingon Alu frame S.Ft. 450
5.04 Railing s.s railing RFT -
10.00 CARPENTRY WORK
10.01 WOODEN RAISED PLATFORM
Providing & Fixing Raised flooring with wooden frame work of size 50mm x 50mm plaed 2'-0"
c/c with 19mm thk marine ply and making in line and level as per design and directed by the
architect.
S.Ft. -
10.02 AMPHITHEATER STEP SEATINGProviding and fixing of running Amphitheater Steps Seating in ply including all the boxing
making niches finished in Rubber wood etc. RFT 150
9.02RAW BOXING WITH FRAME
WORK AND PLY FIXING
Providing & Fixing of 6 mm ply skining With Necessary Wooden Support / Aluminium
Support as per directed S.Ft. 200
10.03 SOFT CUSION SEATINGProviding & Fixing of Ledge seating in Fabric finish as per approved by the architect. Size : (
2100mm X 600mm ) Nos 2
11.00 MISCELLANIOUS WORK
11.01 GLASS PARTITIONProviding and fixing 10 mm thick toughened glass full height Glass Partition with aluminium
frame of size 28x25 mm S.Ft. 1,100
11.02 STRETCH FABRIC CEILING S.Ft. 200
11.03 BAFFLE CEILING
Supply and Installation of METAL Linear Baffle suspended ceiling of approved make. Panel
size 100mm deep x 25mm width using 0.7mm thick, panel length as per architect
requirement, coil coated on a continuous paint line, anchor fastner height atleast 100 mm
SFT 300
11.04ART WORK FOR BREAKOUT
AREA Nos 1
TOTAL -
CENTRAL ZONE CIVIL & INTERIOR WORK
SR. NO. DESCRIPTION QTY UNIT RATE TOTAL
SECTION - A : POWER PANELS & DBs
1 Supply, Installation, Testing, Commissioning of MAIN POWER PANEL-4F as follows : Refer SLD - 1 No
Incommer:
a 1 Nos. 200A, TPN, 35kA, MCCB with Thermal Magnetic releases & with 1NO+1NC as follows :
i. Over load release
ii. Short circuit release
iii. Earth Fault release with CBCT
iv. Shunt release under Fire
v. Rotary operating handle
vi. Indication lamps for R,Y,B and Breaker ON/OFF/Trip
b Dual Load Manager suitable for MD, I, V, KVA, KW, KWH, with required CTs & BMS Port - 1 Sets
c 1 No. CT 200/5A for APFCR.
d Tinned & Sleeved Aluminium Busbar - TPN, 35kA, 200A
Outgoing:
e MCCBs, 35kA, Thermal magnetic adustable releases as follows (with 1NO+1NC):
i. Over load release
ii. Short circuit release
iii. Rotary operating handle
iv. Indication lamps for R,Y,B
1. 80A/100A, TPN, 35kA, MCCB - 5 Nos
f Load Manager suitable for MD, I, V, KVA, KW, KWH, with required CTs & BMS Port - 2 Sets
g MCB, 10kA, C-Curve as follows :
1. 40/63A, 3P, MCB - 3Nos.
2. 16/20/25/32A, 3P, MCB - 9Nos
3. 16/20/25/32A, 1P, MCB -3 Nos
h 40kA, 4 Pole voltage Surge protection - 1 No
i40 KVAR APFCR Panel Section: 3 Phase delta connected APP self healing Cap Banks, Auto Manual Switching, 4 Stage
Intelligent APFC Relay, Timers, Auxiliary relays etc.
The rate shall be including all required Busbar & control wiring. The GA & control circuits shall be first approved, before
fabrication.
The above complete with all accessories
2 Supply, Installation, Testing, Commissioning of 2 x 30KVA UPS O/P Panel, follows : Refer SLD 1 No
Incommer:
a 2 No. 80A, TPN, 25kA, MCCB with Thermal magnetic adustable releases & with 1NO+1NC as follows :
i. Over load release
ii. Short circuit release
iii. Rotary operating handle
iv. Indication lamps for R,Y,B
b Tinned & Sleeved Copper Busbar - 4P, 25kA, 100A
Outgoing:
c MCB, 10kA, D-Curve as follows :
1. 40/63A, 3P, MCB - 5Nos.
2. 16/20/25/32A, 3P, MCB - 0Nos
3. 16/20/25/32A, 1P, MCB -3 Nos
The above complete with all accessories
3
Supply, Installation, Testing & Commissioning of Distribution Boards complete with MCBs/Isolators/ Bus bars and
interconnections. Prefarably standard DB's of specified makes as per list of materials shall be used (DOUBLE DOOR
IP42)
a ETPN DB as follows : RPDB 2 Nos
Incommer 40A TP MCB-- 1 No.
Incommer 40A, 100mA, 2P RCCB- 3 Nos.
Outgoing 16A, SP, MCBs - 30 Nos
Separate Nuetral Bus for Each Phase to be given
b ETPN DB as follows : LDBs 0 Nos
Incommer 25A TP MCB-- 1 No.
Incommer 25A, 100mA, 2P RCCB- 3 Nos.
Outgoing 10A, SP, MCBs - 24 Nos
Separate Nuetral Bus for Each Phase to be given
c ETPN DB as follows : LDBs 2 Nos
Incommer 25A TP MCB-- 1 No.
Incommer 25A, 100mA, 2P RCCB- 3 Nos.
Outgoing 10A, SP, MCBs - 18 Nos
Separate Nuetral Bus for Each Phase to be given
d ETPN DB as follows : UPSDBs 2 Nos
Incommer 32A TP MCB-- 1 No.
Incommer 32A, 2P MCB- 3 Nos.
Outgoing 16A, SP, MCBs - 18 Nos
Separate Nuetral Bus for Each Phase to be given
e ETPN DB as follows : SERVER UPSDBs 2 Nos
Incommer 40A TP MCB-- 1 No.
Outgoing 20/32A, SP, MCBs - 6 Nos
Separate Nuetral Bus for Each Phase to be given
f SPN DB as follows : SECURITY DB 1 Nos
Incommer 25A, DP, MCB-- 1 No.
Outgoing 10/16A SP MCBs -6 Nos.
g SPN DB as follows : ELDB 1 Nos
Incommer 20A, DP, MCB-- 1 No.
Outgoing 10A SP MCBs -6 Nos.
h SPN DB as follows : ACDB 0 Nos
Incommer 32A, DP, 100mA, RCBO-- 1 No.
Outgoing 10/16A SP MCBs -12 Nos.
SECTION - B: LT CABLES
1Supply and laying of Aluminium/Copper Armoured (XLPE FRLS) 1.1KV grade, fixed to walls, ceilings or laid in ready-
made trench or tied to cables trays with cable ties as follows:
a3.5 Core 95 sq. mm. Aluminium Armoured cable. (Main Incoming cable from existing floor elect room to elect/UPS
room)50 Mtrs
b 3.5 Core 50 sq. mm. Aluminium Armoured cable. 0 Mtrs
c 3.5 Core 35 sq. mm. Aluminium Armoured cable. 60 Mtrs
d 4 Core 16 sq. mm. Armoured Aluminium cable with twin 10 SWG GI earth 0 Mtrs
e 4 Core 16 sq. mm. Armoured Copper cable with twin 10 SWG GI earth 0 Mtrs
f 4 Core 10 sq. mm. Armoured Copper cable with twin 12 SWG GI earth 0 Mtrs
g 4 Core 6 sq. mm. Armoured Copper cable with twin 12 SWG GI earth 450 Mtrs
h 4 Core 4 sq. mm. Armoured Copper cable with twin 14 SWG GI earth 0 Mtrs
i 4 Core 2.5 sq. mm. Armoured Copper cable with twin 14 SWG GI earth 100 Mtrs
j 3 Core 6 sq. mm Armoured Copper cable. (For ACDB) 0 Mtrs
k 3 Core 4 sq. mm Armoured Copper cable. 20 Mtrs
l 3 Core 2.5 sq. mm Armoured Copper cable. (for AHUs & APFCR under DG signal) 150 Mtrs
ELECTRICAL LT WORK
2Termination of the above cables with Heavy duty double compression Brass cable glands & copper heavy duty lugs
with bi metallic rings. (4c/3.5c/3c)
a 3.5 Core 95 sq. mm. Aluminium Armoured cable. 2 Nos
b 3.5 Core 50 sq. mm. Aluminium Armoured cable. 0 Nos
c 3.5 Core 35 sq. mm. Aluminium Armoured cable. 2 Nos
d 4 Core 16 sq. mm. Armoured Aluminium cable. 0 Nos
e 4 Core 16 sq. mm. Armoured Copper cable. 0 Nos
f 4 Core 10 sq. mm. Armoured Copper cable 0 Nos
g 4 Core 6 sq. mm. Armoured Copper cable 22 Nos
h 4 Core 4 sq. mm. Armoured Copper cable 0 Nos
i 4 Core 2.5 sq. mm. Armoured Copper cable 4 Nos
j 3 Core 6 sq. mm Armoured Copper cable. 0 Nos
k 3 Core 4 sq. mm Armoured Copper cable. 2 Nos
l 3 Core 2.5 sq. mm Armoured Copper cable. 4 Nos
3Supply & Laying flexible Copper Cables for UPS / Inverter Input & Output Connections in flexible PVC conduits
including terminations with copper lugs:
a Single Core 35 Sqmm Copper cable - 40.0 KVA UPS I/P & O/P 0 Mtrs
Single Core 25 Sqmm Copper cable - 40.0 KVA UPS I/P & O/P 120 Mtrs
b Single Core 4 Sqmm Copper cable - 2.0 KVA INVERTER I/P & O/P 20 Mtrs
SECTION - C: CABLE TRAY & RACEWAYS
1
Supply & installations of Pre Galvanised 40 microns, 2.0mm Thick, 75mm height, readymade Mild Steel Ladder Type
cable trays complete with couplers, bends etc. The rate to include vertical supports of 40x40mmx3mm of angles
fixed with 6mm Anchor fasteners to ceiling. The vertical support shall be placed at interval of not more than 1.5 Metrs &
at all bends.All Vertical supports shall be spary painted with red oxide treatment.
a 450mm wide (In Electrical Room) 10 Mtrs.
b 300mm wide 0 Mtrs.
2
Supply & installations of Pre Galvanised 40 microns, 2.0mm Thick, 75mm height, readymade Mild Steel Ladder Type
cable trays complete with couplers, bends etc. The rate to include supports of 25x25mmx3mm of angle with 10mm
verticle rods fixed with 6mm Anchor fasteners. The vertical support shall be placed at interval of not more than 1.5
Metrs & at all bends.
a 450mm wide 0 Mtrs.
b 300mm wide 20 Mtrs.
c 150mm wide 100 Mtrs.
3
Supply & installations of Pre Galvanised 40 microns, 2.0mm Thick, 50mm height, readymade Mild Steel Perforated
Type cable trays complete with couplers, bends etc. The rate to include supports of 25x25mmx3mm of angle with
10mm verticle rods fixed with 6mm Anchor fasteners. The vertical support shall be placed at interval of not more than
1.5 Metrs & at all bends.
a 150mm wide (For Data backbone from Data Shaft to Server Room) 60 Mtrs.
4
Supply & installations of Pre Galvanised 40 microns, 2.0mm Thick, 60mm height, readymade Mild Steel Perforated
type cable trays, complete with couplers, bends etc.The Cable tray shall be fixed to the Floor with GI C- Clamps of
50mm x 5mm thk, on which the Cable tray shall be fixed. The clamps shall be fixed to floor with 6mm anchore Bolts .
The rate to include all materials & labour. (In Server Room / Hub Room)
a 450mm wide 5 Mtrs.
b 300mm wide 3 Mtrs.
c 150mm wide 0 Mtrs.
5
Preparation of trenches upto 20" wide by carefully removing the floor tiles & malwa below the tiles for laying
Raceways/conduits for power, Data, voice etc. The depth of the trenches shall be atleast 60mm from the finished floor
level or upto RCC of the slab. The rate shall include filling the trenches with rich mix of 1 : 2 PCC after laying of the
Raceway/conduits for smooth finish upto original tile level. The rate shall not include the cost of the Raceways/conduits.
500 Mtrs.
6
Supply and laying Raceways/Conduits in the trenches as detailed above or through partitions with all accessories,
bends, pull wire separately. The metal conduits / Raceways shall be earth. The rate include all accessories but
excluding the floor mounted junction boxes which shall be paid. the rate shall include bends, couplers etc.
a 150mm x 50mm Aluminium Section,2.0mm Thk. 140 Mtrs.
b 100mm x 50mm Aluminium Section,2.0mm Thk. 90 Mtrs.
c 75mm x 50mm Aluminium Section, 1.60mm Thk. 40 Mtrs.
d 63mm x 38mm Aluminium Section, 1.60mm Thk. 100 Mtrs.
e 32mm HMS PVC Conduits 0 Mtrs.
f 25mm HMS PVC Conduits 500 Mtrs.
g 25mm MMS PVC Conduits (For Wi-Fi, AV etc. on Wall / Ceiling) 500 Mtrs.
7
Supply & installations of MS Powder coated, Junction Boxes made of 2.0 mm thk/1.6mm thk, with removal MS Top
Cover 2.0mm thk, all side entries for raceways, complete with all accessories. The rate to include fixing the juncrtion
box on the floor Trenches or floor described above. Sample junction box to be approved first.
a 450mm x 450mm wide x 60mm ht-2.0mm thk 12 Nos.
b 375mm x 375mm wide x 60mm ht-2.0mm thk 4 Nos.
c 300mm x 300mm wide x 60mm ht-2.0mm thk 8 Nos.
d 250mm x 250mm wide x 60mm ht-1.6mm thk 14 Nos.
e 200mm x 200mm wide x 60mm ht-1.6mm thk 14 Nos.
f 150mm x 150mm wide x 60mm ht-16.mm Thk 65 Nos.
SECTION - D : POWER OUTLETS & WIRING
1 Supply and fixing of computer power outlets, Modular type (shuttered) switch sockets.
aSet of 3 nos of 6A Multistandard Socket controlled by 16A Switch. The switch sockets shall be mounted in modular
furniture with face plate & without back box as directed. 100 Nos
aiSet of 3 nos of 6A Multistandard Socket controlled by 16A Switch. The switch sockets shall be mounted in Wall /
partition with face plate & Metal back box as directed. 10 Nos
bSet of 2 nos of 6A Multistandard Socket controlled by 16A Switch. The switch sockets shall be mounted in modular
furniture with face plate & without back box as directed. 15 Nos
biSet of 2 nos of 6A Multistandard Socket controlled by 16A Switch. The switch sockets shall be mounted in Wall /
partition with face plate & Metal back box as directed. 5 Nos
c1Nos 6A Multistandard Socket & 6A Switch. The switch sockets shall be mounted in modular furniture with face plate
& without back box as directed. 110 Nos
ci1Nos 6A Multistandard Socket & 6A Switch. The switch sockets shall be mounted in Wall / partition with face plate &
Metal back box as directed. 10 Nos
d1Nos 6A Socket & 6A Switch. The switch sockets shall be mounted in Wall / partition with face plate & Metal back box
as directed. 40 Nos
e1Nos 6/16A, Socket & 16A Switch. The switch sockets shall be mounted in modular furniture with face plate & without
back box as directed. 0 Nos
ei1Nos 6/16A, Socket & 16A Switch. The switch sockets shall be mounted in Wall / partition with face plate & Metal back
box as directed. 45 Nos
h1Nos 6A Socket. The Sockets shall be mounted in Wall / partition with face plate & Metal back box as directed. (For
VAVs/MFD)0 Nos
i TV out let socket with face plate & metal back box (In Café & Open Workstation area) 10 Nos
j 6W / 8W Splitter fot TV cables 2 Nos
2Supply, installation of RG6 Co-axial cable for TV with PVC Conduits 25mm/32 mm fixed to walls/Ceiling with Spacers &
saddles.400 Mtrs.
3Supply & Laying flexible Copper Cable ( FRLS) for Power sockets for UPS Power /Raw Power through already laid
Raceways/conduits/Cable Trays etc.
a 3 Core 2.5 Sqmm Copper cable. 980 Mtrs.
4Supply & Laying flexible Copper cables ( FRLS) for Power sockets in Sever Room/Hubrooms through already laid
Raceways/conduits/Cable Trays etc.
a 3 Core 6.0 sq. mm Copper cable. 20 Mtrs.
b 3 Core 4.0 sq. mm Copper cable. 0 Mtrs.
5 Supply, installation, testing & comissioning of MCB's in Metal boards, as follows:
a 40/63A, TPN, MCB in Metal boards in IP42 enclosure 0 Nos
b 40/63A, TPN, MCB in Metal boards in IP55 enclosure 0 Nos
c 16/25A/32A, TPN, MCB in Metal boards in IP42 enclosure 2 Nos
d 16/25A/32A, TPN, MCB in Metal boards in IP55 enclosure 0 Nos
e 16/25A/32A, DP, MCB in Metal boards in IP42 enclosure 1 Nos
f 16/25A/32A, DP, MCB in Metal boards in IP55 enclosure 0 Nos
g 16/25A/32A, SP, MCB in Metal boards in IP42 enclosure 0 Nos
h 20A, 2P+E, Reyrol Plug & Socket with 16/20A SP MCB in IP42 Metal enclosure. 0 Nos
i 32A, 2P+E, Reyrol Plug & Socket with 25A SP MCB in IP42 Metal enclosure. 0 Nos
j 20A, 2P+E, IEC, Interlockable Plug & Socket with IP42 Enclosure of SCAME Make (For Server / IT & Network Racks) 6 Nos
k 32A, 2P+E, IEC, Interlockable Plug & Socket with IP42 Enclosure of SCAME Make (For Server / IT & Network Racks) 2 Nos
l 25/32A, 4P, RCBO, 300mA in Metal boards in IP55 enclosure (For VRV ODUs) 2 Nos
m 40/63A, 4P, RCBO, 300mA in Metal boards in IP55 enclosure (For VRV ODUs) 0 Nos
SECTION - E : POINT WIRING
1
Point wiring through MMS 25mm/20mm FR PVC Conduits with 3 Nos of 1.5 sqmm (Phase, Neutral & Earth), PVC
Insulated Copper Conductors FRZH Grade, controlled from MCB in DB . The Light Points from Switch Board/Sensor to
First/Primary Point shall be with 3 Nos of 1.5sqmm. Looped Points from primary to secondary shall also be with
3x1.5sqmm FRZH grade copper wires. Note that the indirect lighting points shall be considered as one single point & no
secondary point will be allowed. Similarly Line Light connections shall be internal & shall not be considered for
secondary point. The Point wiring shall be directly terminated in the fitting through PVC Flexible conduit & coupling
(from ceiling to fitting). The cost for circuit wiring (3x2.5Sqmm) from DB to Switch board & Switch board to
switch board shall be included in the point wiring.
a For primary light points controlled from Switch boards with 6A Modular switches. 120 Nos
b For Secondary light points looped from primary points 250 Nos
c For Secondary light points looped from Sensor to Sensor. 10 Nos
d For primary light points - From DB to 1st Light point/sensor point 25 Nos
e For Exhaust Fan Points with 6A Socket near Fan & 6A Switch on nearest Lighting Switchboard. 0 Nos
2Supply & Laying Circuit Mains for Power sockets/DBs through 25 mm. FR PVC conduits, MMS as follows: (The rate
shall include the cost of conduits & all accessories). Wires FRZH
a 3 Nos.of 1.5 sq. mm. PVC insulated copper conductors. (For VAVs & Fire Dampers) 0 Mrts.
b 3 Nos.of 2.5 sq. mm. PVC insulated copper conductors. (For Service Sockets & Cafe loads) 700 Mrts.
c 2 Nos. of 4 sq. mm + 2.5 sq. mm. PVC insulated copper conductors. 0 Mrts.
SECTION - F : EARTHING SYSTEM
1
Supply and installation of “Chemical Earthing elecrode 80mm dia,Type-39 (Special), burried in ground at depth of
3.0M from ground level with Chemical compound filling. A brick work chamber with plaster to be provided of
300x300x300 Deep with cast Iron cover 10mm thk. with frame and lockable facility. A Test link shall be provided in the
Chamber for Testing Purpose. Make Ashlok or Equivalent
2 Nos
Server Dedicated Earth - 2 nos
2
Supply and laying of earthing strips from earthing chamber to varoius Power Panels and terminating the same. Strip to
be laid through cable trenches/cables trays with required clamping arrangement. The portion on building wall & upto the
main panel shall be fixed with spacers and saddles. Joints shall be lap welded/souldered & coated with bitumen. The
rates shall include cost of all materials & accessories.
a 25mm x 3mm GI earthing strip 0 Mtrs.
b50mm x 6 mm GI earthing strip (To be tapped from Base builder Body Earth Strips running inside floor Electrical
shaft) 100 Mtrs.
3Supply & laying of single core flexible PVC insulated Copper conductor through PVC conduits of suitable sizes thro'
ducts,trays etc. The rates shall include cost of all materials & accessories including termination.
bSingle Core 50 Sqmm Copper cable (For Server Dedicated Earth) Assumed Single length of 125 mtr from
dedicated Earth Pit to 4th floor Server Room250 Mtrs
c Single Core 35 Sqmm Copper cable 0 Mtrs
d Single Core 25 Sqmm Copper cable 0 Mtrs
e Single Core 16 Sqmm Copper cable (For 40KVA UPS Body/Battery Earth) 60 Mtrs
f Single Core 4 Sqmm Copper cable without Conduit (For Rack & False floor Earth) 20 Mtrs
4Supply, Installation, Testing, Commissioning of Earth Bus of following sizes inside powder coated MS fabricated box to
be mounted on insulator as follows:
b 25mm x 6mm x 300mm Long Copper Bus (For Server room) 1 Nos
c 25mm x 3mm x 200mm Long Copper Bus 0 Nos
SECTION - G : MISCELLENOUS
1Supply & Installation of 2 KVA Invertor, 1Phase input & 1 Phase output with 90.0 Minutes Battery back up time
SMF batteries with overload, short circuit protection.1 Nos
2 Supply & Installation of 1.1KV Grade Rubber Mats. 6 Sqm
3 Supply & Installation of Danger Notice Board etc 2 Job
4
Arranging temporary Power & Lighting for all agencies to work including suitable protection through
MCBs/ELCBs/MCCBs & wiring & cabling. Each Floor shall have 3 Locations with switch Boards containing 4 Nos of
6A/16A Switch sockets plus two nos of Metal Clad sockets ( Single Phase ) & one 3 Phase 16A, 5 Pin Metal socket or
16A 3Phase MCB at each location. The Temporary Lighting shall have an average of 150 to 200 Lux at all places
maintained. Temporary Power required is approx 20 Kw per floor, which shall be coordinated with Developer
for required Tap-off arrangement at each floor
1 Job
The rate shall include statutary aproval from Local Electrical Inspectorate & other required satatutary bodies,
Preparation of AS-BUILT drawings, Testing of the installation & preparaition of test report as required by statutary
bodies.
5 Supply & Installtion of Occupancy Sensor for closed Rooms & toilets only 30 Nos.
Make & Model : LRM1071 of Philips or equivalent
TOTAL OF ELECTRICAL -
2 SECTION H : LIGHT FIXTURES 10090 Sq.ft
3 DECORATIVE LIGHT 10090 Sq.ft
Sr. No. DESCRIPTION UNIT QTY RATE AMOUNT
1
Supply & Installation Testing, commissioning of Analouge Addressable Main Fire
Alarm Panel with 1 LOOP PANEL Power supply & battery backup complete as
per following features:
Set 1
Loop Capacity to accomodate the following detectors and devices with 20% spare
LCD display minimum 160 Character
Shall integrate Control,Monitor,Relay modules,Duct Detectors,Beam
Detectors,Flame detectors.
Battery of 48 hrs backup in normal condition,+ 1 hr backup with 25% Loop under fire
condition.
2Addressable type MUILTISENSOR with 9 settable algorithms, base & MS powder
coated Junction boxNos. 3
3Addressable type OPTICAL smoke detector with sensitivity range of 0.5% to 2.35%
per foot with baseNos. 35
4Addressable type OPTICAL smoke detector with sensitivity range of 0.5% to 2.35%
per foot with base & MS Powder coated Junction Box Nos. 44
5
Addressable type Heat detector of rate of rise temperature detection of 15 degree F
to 20 degree F per minute or Fixed temerature with base & MS Powder coated
Junction Box.
Nos. 1
6 Remote response indicator having twin LED flush mounted on false ceiling/wall Nos. 35
7 Addressable Manual Pull station with Reset Lock & Key arrangment with back box. Nos. 6
8 Addressable Sounders 85 DB minimum at 10 feet. Nos. 6
9 Fault Isolator Module,in suitable ABS Plastic glossy Box. Nos. 4
10 Monitor Module Nos. 3
11 Control Module Nos. 6
12
Active Repeater Panel with minimum160 character display for monitoring &
controlling other Panels on the network loop with Power supply. Peer To Peer
Networked with all main panels, such that the status of the entire system shall be
available on individual Annunciator.
Nos. 0
13
Control Cables : 2C x 1.5 mm2, Stranded Copper conductor,Type AST 1 PVC
insulated,Armoured FRLS Cable 650 V as per IS 1554, with GI saddle spacers
every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes
(wherever required ), terminals,Ferruling complete.
MTR 1000
TOTAL
FIRE ALARM SYSTEM
Sr. No. DESCRIPTION QTY UNIT RATE AMOUNT
MAKE: BOSCH
B PUBLIC ADDRESS SYSTEM
1
Metallic Grill, high quality type music speakers to be fixed flushed with false
ceiling with line matching transformer for direct connecting to 100/70 V output
line.
6 Watt Output 40 Nos
1.1 Junction box for Open ceiling Speakers 25 Nos
2 Metal Cabinet Speakers Wall mounted - 6 Watts output 0 Nos
(Non False Ceiling Areas )
3
Volume control - cum - ON - OFF switch flush mounted on wall along with
other electrical switches with size & regulating knob matching the electrical
fittings,upto 25 Watts
35 Nos
4 8 zone controller with Voice Evacuation system 0 Nos
58 zone Mic Goose neck Microphone to be connected peer to peer with the
ampilifier0 Nos
6
Control Cables : 2C x 1.0 mm2, Stranded Copper conductor,Type AST 1
PVC insulated, Armoured FRLS Cable 650 V as per IS 1554, with GI saddle
spacers every 0.3 mtr with Single compression Cable Glands, ABS Junction
Boxes (wherever required), terminals, Ferruling complete.
1300 Mtr
Century/Supercab/RR
7 Main amplifier 240 watt 1 set
8 Booster Amplifier -480 Watt 0 R/0
TOTAL 0
PA SYSTEM
Sr. No. DESCRIPTION UNIT QTY RATE AMOUNT
D CCTV SURVEILLANCE SYSTEM
Supply, Installation,Testing Commissioning of Standalone
CCTV System comprising of following:
11/3" format IP -IR Color Camera with 1 MP , 0.001 lux , 3.6mm
Fixed lens suitable to operate at day and nightNos 16
HIKVISION/CP PLUS/Dahua
2 CAT 6 Cables Mtrs 900
Century/Supercab/RR
3
Medium Grade - 25mm FRPVC Conduit with fittings ISI
Marked with GI saddle & spacers at every 0.3 Mtr and flexible
conduits for all drops above false ceiling.
Mtrs 0
4Monitor,19" high perfomance LCD TFT 100-230 VAC 50
Hz.24x7 with wall mounted swivel standNos 1
5 Wall Mount Bracket for Monitor Nos 1
6 16 Port POE switch Nos 1
7 8 port LAN Switch Nos 0
HIKVISION
8 NetworkDigital Video Recorder
Embedded linux/Windows, MPEG4 compression
LAN/TCP/IP, Networked Pentaplex operation
Schedule/Motion/Alarm sensor recordings / continuous
Server to Server configuration
Upto 16 Alarm input & 8 Relay output
Alarm notification via email
Smart search, Post & pre alarm recording
Water marking, PTZ control, Password protection
Minimum 1000 GB HDD or 30 days storage whichever is on
higher side, 1 TB memory, expandable with builtin DVD
Writer.
Upto 16 simultaneous views from different DVRS on same
LAN on single screen
Network bandwidth trottling from 128 Kbps to 10 Mbps
16 port -Display 400 fps, Recording 200 fps Nos 1
HIKVISION/CP PLUS/CNB
9 2TB HDD Nos 1
TOTAL OF CCTV 0
CCTV SYSTEM
Sr. No. DESCRIPTION QTY UNIT RATE AMOUNT
C CARD ACCESS CONTROL SYSTEM:
1Network Intelligent 32 BIT Native Onboard IP Access Control panels for Smart Card or a
group of Panels capable of controlling all the Card Readers as spec`s below:
Intelligent embedded network device for access control and alarm monitoring.
Firmware stored in flash memory that is easy to update on LAN Network.
Multiple card reading technologies supported, Proximity, Smart card, Biometric
Variable card formats supported.
Multiple facility codes supported
Remote database administration
Remote alarm monitoring
Inbuilt database backup to facilitate offline use
Local, Global, Soft, Hard Anti-pass back supported
Automatic locking & unlocking of the doors
Doors Considered - Main door , Locker room,
4 Door/8 Reader Set 1
2 Door / 4 reader Set 0
SPECTRA
2 Smart Card Reader - 3" Read Range No 8
HID
3Fingerprint Biometric with builtin Smart card Reader, Power supply with wiegand output
fully networkable.No 0
(To include 1 set of Biometric enrolling kit complete )
L1 Identity OR EQV.
5 Electromagneitc Lock with builtin Magnetic contacts, L & U brackets 600 lbs capacity No 4
ALGATEC
6 Egress Switch - Proximity based No 2
9 Magnetic contacts and piezo sounders for Fire Exits No 1
10 Panic bar for Fire Exits No 1
DORMA/SB/INGERSOLRAND
11 Access Control Enterprise version Server Software with following features: No 1
Muilticity,Muilti client
Distributed intelligence for central & remote configuration.
unlimited expansion
Supports IP Series (Ethernet ready) controllers.
Windows based Operator work stations.
ODBC Compliant
Broadcast feature for central control on controllers & equipments
Full reporting capabilities and custom reports
Support upto 32 Clients
with 1 Client License Software FOR 300 USERS
SPECTRA
12 Emergency Release Switch in Green Polycarbonate housing,push to breakglass type. No 3
13 Smart Cards.-BLANK - HID No 300
14 AB Copper flexible Cable PVC insulated, shielded FRLS Sheathed layed in below conduit
a 8 c x 0.75 Sq.mm Mtrs 300
b 4c x 0.75 Sq.mm Mtrs 200
c 2c x 0.75 Sq.mm Mtrs 200
Century/Supercab/RR
15Medium Grade - 25mm FRPVC Conduit with fittings ISI Marked with GI saddle & spacers
at every 0.3 Mtr and flexible conduits for all drops above false ceiling.Mtrs 300
TOTAL of ACCESS 0
ACCESS CONTROL SYSTEM
SR.NO DESCRIPTION UNIT QTY RATE AMOUNT
B. FIRE EXTINGUISHERS
Supplying, installing and commissioning Portable Fire extinguishers of following type
& capacity.
1.00
ABC type fire extinguisher of 6 kgs. Capacity, Brand new seamless cylinder with
powder coated finish, made out of Manganese steel, with wheel type valve,
discharge nozzle, bend & horn, with floor stand and Triangle type auto glow fire
extinguisher sign board, etc. complete, confirming to IS 15683 with floor stands as
per New BIS and as per technical specification with all mounting accessories
complete as required.
Nos. 20.00
2.00 CO2 Fire extinguisher 4.5 kg Nos 1.00
3.00 FOAM EXTINGUISHER 9 Ltr Nos -
4.00 6 KG Clean Agent Nos 1.00
TOTAL OF FIRE EXTINGUISHER -
FIRE EXTINGUISHER
SR.NO DESCRIPTION UNIT QTY RATE AMOUNT
Supply, Installation, Pressure and leak Testing with required equipment &
Commissioning of the following as per technical Specifications with all mounting
accessories ( Angles, High tech rods , fasters, clamps etc.) , painting the pipes , water
pressure testing to the industry standards vendors shall consider all required
accessories to complete the functionality of the system
A SPRINKLER SYSTEM
1
Providing & laying GI C class heavy duty pipes fittings screwed ends which shall stand
300lbs pressure conforming to IS-1239.The item includes tees, elbows, reducers, union,
flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor /
wall /ceiling with clamps, hangers (using anchor fasteners) as per specification. G.I. pipe
sleeve of suitable higher size shall be provided.
a 150mm NB Mtrs 18
b 100mm NB Mtrs 18
c 80mm NB Mtrs 24
d 65mm NB Mtrs 36
e 50mm NB Mtrs 45
f 40mm NB Mtrs 72
g 32mm NB Mtrs 110
h 25mm NB Mtrs 300
2
Providing, fixing & testing of Pendent Type fire sprinklers with 15mm dia & Quick Response
Type with cover plate, on the piping at correct location & level as directed. The sprinkler shall
consist of glass bulb, bulb cap,frame,deflectors, rosette plates, etc. suitable for working
temperature of 68°C. The sprinkler should withstand test pressure of 12kg /Sq. cm. The
Sprinkler frame, bulb cap and deflector shall be made up of bronze .The rate shall include all
the necessary supports, fittings
a Concealed type Pendent sprinkler Nos.
b Pendent Type with rosette caps Nos. 55
c Upright type Nos 110
d Side Throw type
3
Flexible drop of 1000mm long (UL Listed) as per the specification (stainless steel unbraided
metallic outer jacket with stainless steel internal bellows) with Cross bar supports to hold the
sprinkler flexible drop as per technical specification with all mounting accessories complete as
required.
Nos
4
Flexible drop of 1500mm long (UL Listed) as per the specification (stainless steel braided
metallic outer jacket with stainless steel internal bellows) with Cross bar supports to hold the
sprinkler flexible drop as per technical specification with all mounting accessories complete as
required.
Nos 45
5
Flexible drop of 2000mm long (UL Listed) as per the specification (stainless steel unbraided
metallic outer jacket with stainless steel internal bellows) with Cross bar supports to hold the
sprinkler flexible drop as per technical specification with all mounting accessories complete as
required.
Nos
6Supplying, installing, testing and commissioning OF 150mm BFV as per technical
specification with all mounting accessories complete as required.Nos. 1
7Supplying, installing, testing and commissioning OF 80mm BFV as per technical specification
with all mounting accessories complete as required.Nos.
8Supplying, installing, testing and commissioning OF Flow switches as per technical
specification with all mounting accessories complete as required.Nos. 1
9Supply, Installation, Testing & Commissioning of Drain valve as per site requirement and as
per technical specification with all mounting accessories complete as required.No 1
10
Supply, Installation, Testing & Commissioning of Special Fitting for below AC Units / Duct as
per site condition and as per technical specification with all mounting accessories complete as
required.
Nos
12 Pressure Gauge No 1
Make- H-Guru
13 Flow Switch No 1
Make - Honeywell
14 Modification charges NO -
TOTAL OF SPRINKLER 0
SPRINKLER-MAKE JINDAL /SAFEX/NEWAGE
S. NO. DESCRIPTION TOTAL QTY UNIT RATE TOTAL ADDITONAL QTY AMOUNT
BOQ Considerations :
1. The BOQ is based on Data Matrix dated 22.01.2019
2. Data & voice separate system
3. Patch Cords for Active Data Nodes at Both End (Desk & Rack End)
4. Patch Cords for Active Voice Nodes at Rack End
5. Voice cable Termination on Patch Panel & Switch connectivity
6. 24 Port Straight Jack panel
7. Cat-6 Cabling for Data/Voice
8. Open Frame network Racks for Data & Voice
9. Avg. length for Cat-6 Cabling = 48 Mtr.
10. Dual Fiber from 4th floor to 16th floor server room & 4th floor to 11th floor server room
11. Make : Systemax
COLOUR CODES FOR INFORMATION OUTLET AT DESK & RACK END & PATCH CORDS.
1. Active Data - Blue
2. Redundant Data - Orange
3. Active Voice - Red
A HORIZONTAL CABLING COMPONENT FOR DATA
1 CATEGORY-6, 4PAIR UTP CABLE 44 BOX 22 -
2 CAT-6, INFORMATION OUTLET 274 NOS 137 -
3 CAT-6, 24 PORT LOADED JACK PANEL STRAIGHT- FOR ACTIVE DATA 7 NOS 0 -
4 CAT-6, 24 PORT LOADED JACK PANEL STRAIGHT- FOR RED. DATA 6 NOS 6 -
5 CAT-6, 7FT PATCH CORD - AT RACK END - FOR ACTIVE DATA 146 NOS
6 CAT-6, 7FT PATCH CORD - AT WORKSATION END FOR ACTIVE DATA 146 NOS
B HORIZONTAL CABLING COMPONENT FOR VOICE
1 CATEGORY-6, 4PAIR UTP CABLE 18 BOX
2 CAT-6, INFORMATION OUTLET 111 NOS
3 CAT-6, 24 PORT LOADED JACK PANEL STRAIGHT - FOR VOICE 5 NOS
5 CAT-6, 7FT PATCH CORD - AT RACK END - FOR VOICE 111 NOS
C FACE PLATES & METAL BACK BOXES FOR DATA & VOICE
1 FACE PLATE DUAL/QUAD - FOR DATA & VOICE 133 NOS
2 2 MODULE SURFACE MOUNTED METAL BACK BOX - ON WALLS ETC. 10 NOS
D BACK BONE - FROM SERVER ROOM TO HUB ROOMS
1 6 CORE 50/125 U MM ARMOURED FIBER CABLE 300 MTRS 300 -
2 600 G2 SHELF 3 NOS 3 -
3 600 G2 LC 24 DUPLEX PANEL 3 NOS 3 -
4 ROLO SPLICE TRAY 3 NOS 3 -
5 LC DUPLEX ADAPTER 12 NOS 12 -
6 LC 50/125 U MM, PIGTAILS 24 NOS 24 -
7 Duplex, LC-LC, 50/125 U MM FIBER OPTIC PATCH CORD, 5 MTR 8 NOS 8 -
8 Duplex, LC-LC, 50/125 U MM FIBER OPTIC PATCH CORD, 10 MTR 0 NOS -
F ANALOGUE VOICE COMPONENTS & RISER CABLES
1 20+20 PAIR KRONE BOX, WITH CABLE MANAGERS ETC. 1 NOS
2 1 PAIR JUMPER WIRE - REEL OF 1000 FEET 0 REEL
3 25 PAIR ARMOURED RISER CABLE (For Service provider) 50 MTRS
G NETWORK RACK
1
45U OPEN FRAME RACK FOR STRAIGHT JACK PANELS WITH DUAL POWER STRIP
(16A, IEC SOCKETS) & COMPLETE WITH CABLE MANAGERS, REQUIRED SUPPORTS,
ETC. : NETWORK RACKS (1 DATA RACK+1 VOICE RACK)
2 NOS
H SCANNING, CERTIFICATION, DOCUMENTATION, LABELLING & ASBUILT DRAWINGS. 1 LS
TOTAL - -
NETWORKING WORK
REDUDUNT DATA POINT
Data
Active
Data
Red.Voice
Data
Active
Data
Red.Voice
1 General Workstations 73 1 1 1 73 73 73
2 Cabins 16 1 1 1 16 16 16
3 Interview Room : 2 Seater 1 1 1 1 1 1 1
4 Meeting Room : 4 Seater 1 2 1 1 2 1 1
5 Conference Room : 9 Seater 1 4 4 2 4 4 2
Conference Room : 9 Seater : AV/VC 12 1
2 0 1
6 Board Room : 18 Seater 1 10 5 2 10 5 2
Board Room : 18 Seater : AV/VC 1 2 1 2 0 1
7 Anti Chamber 1 1 1 1 1 1 1
8 Reception 1 1 1 1 1 1 1
9 Repro Counter 2 2 1 4 0 2
10 Library : VC 2 2 1 4 0 2
11 Pantry Area 2 1 1 1 2 2 2
12 Server Room 1 1 1 1 1 1 1
13 LCD TV Points at Columns 8 1 1 8 8 0
14 Wifi Point 5 1 1 5 5 0
15 Security System/Misc. 1 10 10 5 10 10 5
Total 118 146 128 111
4TH FLOOR, VISHWAROOP IT PARK, VASHI
Sr.
No.Location
User
Head
Data & Voice Outlets
Per Head Total
DATA MATRIX
SR.NO DESCRIPTION UNIT QTY RATE AMOUNT
1.10 INLINE FANS:
The inline fans shall be complete with centrifugal fan, unit casing access door, electrical connections canopy fan shall
be suitable for installation A/C contractor to include all accessories for installation of inline fan.
a 2000 cfm and 25mm static - Fresh air fan Nos. 1
b 800 cfm and 20mm static - Toilet Exhaust Nos. 1
1.11 Battery Room Exhaust Fan
Supply, Installation, Testing & commissioning of Ceiling Suspended DIDW Cabinet type fans shall be complete with
centrifugal fan, frame work, EEF Class 1motor, belt, electrical connections , elect. Panel fan shall be suitable for indoor
installation A/C contractor to include all accessories
Local BMS compatible Control Panel for UPS / battery Room Exhaust fan with DOL Starter & 24Hrs Digital
programmable timer & 24V Transformer with PLA Relays for Fire system & Hydrogen Sensor system to be included
a 150 CFM, 25MM static, Nos. RO
1.12 300 mm dia. Propeller fan suitable for 220±6% volts 50 cycles, 1 phase AC supply. Nos. RO
a Supply, installation, testing and commissioning of cubicle type fully compartmentalized totally sheet steel enclosed LT
panel suitable for 415V, 50 Hz.
(i) Panel for Ceiling Suspended CSUs with star/ delta starter complete with cabling upto CSU motor Nos. 2
Supply and laying of Necessary Cabling from panel to AHU,
Unless specified the voltage grade of all LT Power and Control cables shall be rated for 1100 Volts.
Vendor shall consider necessary clamping and tagging of cables as part of cable laying work. The cable laying shall be
on cable trays as the case may be.
Vendor shall consider Double compression glands.Terminating Lugs - Aluminum lugs for aluminum conductor cables
and copper lugs for copper conductor cables.
XLPE Insulated, steel round / flat armored, copper conductor cables - multi core
b 4C x 4 Sq.mm Rmt RO
c End Termination - Supply & Installation Nos. RO
d 3C x 2.5 Sq.mm Rmt 30
e End Termination - Supply & Installation Nos. 6
f Supply and Laying of 150 mm wide Ladder Type cable trays for Laying of cables / Earthling (1.6 mm thick) Rmt 20
g Supply and Laying of 25 x 3 Earthing strip Rmt 25
h Supply and Laying of 8SWG Earthling wire copper Rmt 25
2 CHILLED WATER PIPING WITH VALVES & ACCESSORIES
2.1
Supply & erection of the following factory rolled MS 'C' class pipes with specified wall thickness cut to required lengths
and installed with all welded joints, Providing and fixing in position necessary fittings like bends, elbows, tees, reducers,
mating flange joints. With 2 Coats of primer & one coat of enamel paint before installing.
100mm dia. Rmt 5
80mm dia. Rmt 20
65mm dia. Rmt 15
50mm dia. Rmt 60
40mm dia. Rmt 25
32mm dia. Rmt 5
25mm dia. Rmt 30
2.2 Chilled Water Piping Insulation: ( Nitrile Rubber)
Supply, installation, testing & commissioning of insulation for chilled water piping. 25mm thick Nitrile Rubber covered
with Woven Glass Fibre Covering for Mechanical & UV Protection as per specifications.
100mm dia. Rmt 5
80mm dia. Rmt 20
65mm dia. Rmt 15
50mm dia. Rmt 60
40mm dia. Rmt 25
32mm dia. Rmt 5
25mm dia. Rmt 30
2.3
Supply, installation, testing & commissioning of following sizes of butterfly valve with lug type construction, bolts,
supports complete with insulation covered with woven Glass Fibre Covering for Mechanical Protection as per
specifications etc.
50mm dia. Nos. 4
40mm dia. (Ball valve) Nos. 4
25mm dia. (Ball valve) Nos. 8
2.4
Supply, installation, testing & commissioning of following sizes of Double regulating valve / Balancing Valve with
matching flanges, bolts, supports complete with insulation covered with woven Glass Fibre Covering for Mechanical
Protection as per specifications etc.
50mm dia. Nos. 1
40mm dia. Nos. 1
25mm dia. Nos. 2
2.5
Supply, installation, testing & commissioning of following sizes of Motorized 2/3 way motorized modulating control
valve with actuator, thermostat & other accessories including matching flanges, bolts, supports complete with insulation
covered with woven Glass Fibre Covering for Mechanical Protection as per specifications etc.
43.2 GPM (18.0 TR) Nos. 1
24.0 GPM (10 TR) Nos. 1
6.0 GPM (2.5 TR) Nos. 1
HVAC LOW SIDE
2.6Supply, installation, testing & commissioning of following sizes of Y strainer with matching flanges, bolts, supports
complete with insulation covered with woven Glass Fibre Covering for Mechanical Protection as per specifications etc.
50mm dia. Nos. 1
40mm dia. Nos. 1
25mm dia. Nos. 1
2.7 Providing and fitting Auto Vent Valves.
1 " dia. Nos. 2
3/4 " dia. Nos. 5
2.8 Necessary pressure gauges and thermometers
Pressure gauges with Brass/SS syphon and petcock Nos. 2
Thermometers Nos. 2
Thermowells Nos. 10
BTP- Binders test point Nos. 10
Drain cock 25mm dia Nos. 8
3 REFRIGERANT PIPING AND CONTROL CABLING
Supply and laying of copper piping with necessary imported fittings, Y-joints and headers etc.,
3.1 FOR VRV UNITS
Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber type tubular insulation
between indoor & outdoor units as per approved shop drawing and technical specifications . All piping inside the room
shall be properly supported with hanger and all external piping shall run in covered cable tray. The copper piping should
be align properly when running in the ceiling. The quote should also includes the pressure testing of copper pipe &
necessary fittings, Y-joints and headers etc.
3.1.1 41.3mm OD (insulation = 19mm thick) RMT 5
34.9mm OD (Insulation = 19mm thick) RMT 25
28.6mm OD (insulation = 19mm thick) RMT 10
22.2mm OD (insulation = 19mm thick) RMT 45
19.1mm OD (insulation = 19mm thick) RMT 50
15.9mm OD (insulation = 19mm thick) RMT 20
12.7mm OD (insulation = 19mm thick) RMT 10
9.5mm OD (insulation = 19mm thick) RMT 30
22.2mm OD (insulation = 13mm thick) RMT 5
19.1mm OD (insulation = 13mm thick) RMT 25
15.9mm OD (insulation = 13mm thick) RMT 10
12.7mm OD (insulation = 13mm thick) RMT 50
9.5mm OD (insulation = 13mm thick) RMT 20
6.4mm OD (insulation = 13mm thick) RMT 40
3.1.2 SITC of refnet joints for above units & distribution Nos. 35
3.2 Control cabling with necessary conduiting between VRV indoor and outdoor units. RMT 200
3.3 Supply, installation, testing and commissioning of Protective layer for exposed copper piping. Self adhesive Woven
fibre glass cloth shall be 7mm thick and 200 gsm and shall be wrapped around copper piping tubular insulation by using
UV paint. RMT 25
3.4 Provide adequate size enclosed GI cable tray to cover and protect the exposed refrigerant pipes and cabling for all the
VRF/DX Split units.. RMT 25
3.5 Supply wire between VRV indoor unit to the socket RMT 62
3.6 Three pin tops for VRV indoor units NOS. 31
3.7 Supply cable between individual outdoor unit to the isolators, near outdoor units along with termination using armoured
copper cable laid in GI traysRMT 20
3.8 Electrical Distribution Panel for outdoor units. IP-55 protection suitable for outdoor installation for VRV outdoor units.
incomer : 160A TP+NL MCCB 25ka O/C + S/C adjustable thermal for outdoor HP. Outgoing: 3 Nos. upto 63A pole
MCB+ELCB, sensitivity 100mA,MCB rated at 10kA with terminals and wiring upto cable alley. Final rating for MCB shall
be as per unit HP.
Note: Outdoor panel shall be design as per incoming power and outgoing to nos of outdoor unit based on the system
design and shall be approved by the consulatant before execution.
Nos. 1
3.9 Supply, laying and connection of copper earthing of following sizes:
50 x 10 mm GI Strip RMT 5
25 x 3 mm GI strip RMT 15
8 SWG copper wire RMT 15
10 SWG copper wire RMT -
12 SWG copper wire RMT -
3.10 INSULATED DRAIN PIPING
SITC of drain piping complete with PVC, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves,
hangers, supports, anchors and insulation using tubular 9 mm nitrile rubber.The piping shall be connected to the
nearest drain pipe at site.
a 25mm dia RMT 15
b 32mm dia RMT 90
c 40mm dia RMT 35
d 50mm dia RMT 20
4.0 AIR DISTRIBUTION
4.1
Supply, Fabrication, installation, testing & commissioning of Factory fabricated GSS ducting complete with splitter
dampers, turning vanes, access doors, supports, etc. as per approved drawings Ducting to be as per SMACNA
standards. Galvanizing shall be class VII-light coating of zinc,nominal 120 gm/sq.m and lock forming quality prime
material.
b 24 G GI Ducting Sqm 85
c 22 G GI Ducting Sqm 40
d 20 G GI Ducting Sqm 10
4.2 FACTORY FABRICATED FLAT OVAL DUCTING
Supply, installation, testing and balancing of factory fabricated OVAL ducts using GI Sheets. The price shall include T-
joints(Branch piece) flanges, turning vanes, supports (factory fabricated Wire Rope Hangers & Supports (Gripple / Tie
rod Supports) complete with end fixing), sealent (neoprene gasket), hangers etc. The joints shall be 100% leak proof.
The duct should be factory fabricated & painted with 2 coats powder coated from factory itself. Ducts should
brought to site with proper covering. Colour shall be confirmed later by architect. The color shade shall be
approved by architect.
a Upto 600mm- 24 G Ducting Sqm 130
b 600mm-1200mm- 22 G Ducting Sqm 55
c 1200mm and above 20 G Ducting Sqm 30
4.3 DAMPERS
4.3.1
Supply, Installation, testing Commissioning and Balancing of UL listed and CBRI approved fire dampers with fusible
link for atleast 120 mins rating. The dampers shall be made out of high quality galvanized sheet with spring holder,
steel springs, suitable links, with UL listed fusible links as per approved shop drawings.
a Dampers Sqm 1
b Fusible Link Nos. 4
4.3.2
Supply, Installation, testing Commissioning and Balancing of UL listed and CBRI approved fire dampers with motorized
actuator for atleast 120 mins rating. The dampers shall be made out of high quality galvanized sheet with spring holder,
steel springs, suitable links, with UL listed actuator as per approved shop drawings.
a Dampers Sqm RO
b Motorized Actuator Nos. RO
4.3.3
Supply, installation, testing and commissioning of multi blade opposed blade GSS dampers for ducts to be provided
with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air
distribution system.
Sqm 1
4.3.4
Supply, installation, testing and balancing of GSS Volume Control Oval shape Dampers with operating handle for
Supply air duct branches in accordance with the approved shop drawings and specifications as per the sizes
mentioned in drawings.
Sqm 3
4.3.5
Supply , installation and testing commissioning of black multi blade type box dampers of Al. construction for ducts
collars to be provided with suitable links, vertical blades, levers and quadrants for manual control of volume of air flow
and for proper balancing of the air distributions system.
Sqm 1
4.3.6.1 SITC of Fire retardant Flexible canvass/Reksin connections for above CSU, Ductable Nos. 3
4.3.6.2 SITC of Fire retardant Flexible canvass/Reksin connections for FCU equipment Nos. 28
4.3.7 SITC of Fresh air cowl connection with bird screen and volume control dampers Sqm 1
4.3.8 Supply, Installation, testing & commissioning of Gravity louvered damper (back draft damper). Sqm 1
4.4 GRILLS / DIFFUSERS
4.4.1
Supply, installation ,testing and balancing of tiled square supply air diffusers as per the approved shop drawing and
specifications. Each diffuser shall be equipped with fixed air distribution grid, removable core for proper balancing of air
distribution system a.Powder coated extruded aluminium diffusers of approved colour and shade of size 600mm x
600mm suitable for installation in modular ceiling with sizes of active sections given below. The diffusers to be full tile
with the non- active portions blanked Off from above.All diffusers to look alike when viewed from below irrespective of
the sizes.
a 450 x 450 Nos. 2
b 375 x 375 Nos. 3
c 300 x 300 Nos. 3
d 225 x 225 Nos. 1
4.4.2
Supply, installation ,testing and balancing of tiled square return air diffusers without collar dampers as per the
approved shop drawing and specifications. Each diffuser shall be equipped with fixed air distribution grid removable
core for proper balancing of air. a.Powder coated extruded aluminium diffusers of approved colour and shade of size
600mm x 600mm suitable for installation in modular ceiling with sizes of active sections given below. The diffusers to
be full tile with the non- active portions blanked Off from above.All diffusers to look alike when viewed from below
irrespective of the sizes.
a 450 x 450 Nos. 2
b 375 x 375 Nos. 3
c 300 x 300 Nos. 3
d 225 x 225 Nos. 1
4.4.3
Supply, installation, testing and commissioning of Spill Air Plenum / Mixing boxes made of 24G G.I sheet with
necessary spigot connection & Spigot damper for fixing flexible duct and suitable collar for connecting to various neck
diffuser. The box should be internally insulated with 6mm thick nitrile rubber. And with necessary chains for
supporting and anchor fasten in accordance with the approved shop drawings and technical specifications of following
sizes.
a 450 x 450 Nos. 2
b 375 x 375 Nos. 3
c 300 x 300 Nos. 3
d 225 x 225 Nos. 1
4.4.4
Supply, installation ,testing and balancing of Extruded Aluminium powder coated circular supply air diffusers with
damper as per the approved shop drawings and specifications. Each diffuser shall be equipped with fixed air
distribution grid, removable core for proper balancing of air distribution system
a 300mm dia Nos. 1
b 250mm dia Nos. 1
4.4.5
Supply, installation ,testing and balancing of Extruded Aluminium powder coated circular return air diffusers without
damper as per the approved shop drawings and specifications. Each diffuser shall be equipped with fixed air
distribution grid, removable core for proper balancing of air distribution system
a 300mm dia Nos. 1
b 250mm dia Nos. 1
4.4.6Supply, testing, commissionig and balancing of one way blow Aluminium extruded powder coated continuous Linear
grilles for supply and return air with 4 side flanges and as per approved colour shade by the architect.
a 100 mm wide Rmt 130
b 150 mm wide Rmt 10
c 200 mm wide Rmt 10
4.4.7
Supply, testing, commissionig and balancing of one way blow Aluminium extruded powder coated Curved Linear
grilles to suite the oval duct as per shop drawings for supply air with 4 side flanges and as per approved colour
shade by the architect.
a 100 mm wide with dampers Rmt. 30
b 150 mm wide with dampers Rmt. 10
4.4.8
Supply, Installation, testing and commissioning of multi slot supply air diffuser complete with flanges. Diffusers shall
be provided with adjustable pattern adjustment. The pattern controllers shall be positive positioning when providing a
horizontal air path. Constant static pressure shall be maintained at a fixed volume under all positions of pattern
adjustment.Diffusers shall be suitable for positive screw type installation to provide a blemish free appearance. Vendor
to include costing for hit & miss dampers and supply air plenum box as per specifications
a 3 slot, 20 mm slot (With Hit & miss collar dampers for Supply Air) Rmt 2
b 3 slot, 20 mm slot (Without collar dampers) Rmt 5
4.4.9Supply, testing, commissionig and balancing of Aluminium extruded powder coated grilles for exhaust air with 4
side flanges and as per approved colour shade by the architect.
a 150 x 150 with collar damper Nos. 12
4.5Insulated Flexible duct connection to supply air diffuser of plenums. Flexible ducts to be made of aluminium foil both
inside and outside encapsulating a steel wire helix (UL 181 class1).
a 150 mm dia Rmt 5
b 200 mm dia Rmt 15
c 250 mm dia Rmt 10
d 300 mm dia Rmt 10
e 350 mm dia Rmt 5
4.6Factory fabricated Z type Cross Talk Silencer (area calculation : (400x300) Supply and Fixing of Cross Talk silencer
fabricated using 22G GI Sheets with internal 25mm thick fiberglass Twiga insulation.Nos. RO
4.7
Supply, Installation, Testing and Commissioning of the Air Volume Flow Limiter of approved make suitable for duct
installation at any orientation and to be precise to +/- 10% to regulate the airflow relative to the specified maximum air
flow.
0- 50 cfm Nos. 25
5 INSULATION
5.1
Supply, Installation, testing and Commissioning of Acoustic lining of duct work with 25mm thick bitumen fiberglass
stick using shalikote primer hot and mechanically fastened, covered with RP tissue and 30G aluminum perforated sheet
as per specs. Acoustic lining shall be rigid board.
Sqmtrs 40
5.2Supply Installation, Testing and commissioning of Supply Duct insulation 9mm thick closed cell elastomeric nitrile
foam rubber insulation class O stuck to duct as per specifications. (For Outside Duct Insulation)Sqmtrs 110
5.3Supply Installation, Testing and commissioning of Supply Duct insulation 9mm thick closed cell elastomeric nitrile
foam rubber insulation class O stuck to duct as per specifications. (The duct should be internally insulated)Sqmtrs 200
TOTAL OF LOW SIDE -
SR.NO DESCRIPTION UNIT QTY RATE AMOUNT
[A] HVAC System HIGH SIDE
1.0 EQUIPMENTS
1.2
Supply of Ceiling Suspended Chilled Water Fan Coil Type Units, complete with 3/4 Row Chilled Water Coils with
max working pressure of 8 Bar, coils to be tested for 21 bar max, dynamically balanced low noise type centrifugal
section, multi speed single phase fan motor with permanent capacitor, automatic thermal protector with standard
opening on the winding, resilient mounts , washable type filters with filtering efficiency of 60% or EU-1 filter levels. Unit
casing shall be of Galvanized corrosion resistant / powder coated with internal insulation of 10mm insulating foam,
External insulation of 3mm thick insulating foam, 4 way diffusion with adjustable blades. Fresh air intake opening of
minimum 100mm dia with self adjusting damper module, inbuilt condensate drain pump, insulated drain tray with
injected polystyrene for leakage prevention etc. Units shall be factory fitted with valve package comprising of 2/3
way motorized valve Siemens (Landis & Staefa), Sauter, Belimo, make or equivalent make with Cooling Thermostat,
ball valve with 'Y' strainer at inlet & ball valve at outlet and necessary copper coil piping connections. Unit capacities
are as mentioned below.
1.5 TR / 600 cfm Nos. 1
1.3
Supply of Variable Refrigerant Volume Inverter driven type air-conditioning system with wide range of indoor and
outdoor units, with longer actual and total piping length and with high external static pressure. The system consists of
multiple indoor units ranging from high wall, fancoil, ducted type, etc.. connected to a single or multiple modular type
outdoor units with individual controllers to each indoor unit, refrigerant piping, control cabling and also centralized
controller. The specifications and details are as below:
Supply, Installation, Testing & Commissioning of Variable Refrigerant Volume / Flow (VRV/VRF) modular type
outdoor air-conditioning system which consists of Inverter compressors, condenser fan, motor & condenser coils,
control panel it should also include high & lower pressure switch, fuses, fusible plug for condensing unit in accordance
with the approved shop drawings and technical specifications. The vendor can select their configuration based on the
models available and their unit performance. However, the selection capacity of the outdoor unit should be in line with
the specification and concept briefed in the tender document/drawing. The quote should also include outdoor
connecting kit and power cable from isolator provided by others to out door unit. The Vendor should select the
equipment as per Thane condition. The VRV unit should be compatible with third party BMS system through
Bacnet output protocal.a 32 HP - Top Discharge Nos. 1
b 8 HP - Side Discharge Nos. 2
1.4 Supply and installation of MS Structure for ODU's with non-corrosive paint Nos. 3
1.5Supply, Installation, Testing & Commissioning of following VRV Indoor unit with evaporation coil expansion valve and
corded / cordless remote in accordance with the approved shop drawings and technical specifications.
a 8.0 TR High Static Ductable Unit Nos. -
b 4.0TR Ductable Unit - For Server Room Nos. 2
c 2.6TR Ductable Unit Nos. -
d 2.0TR Ductable Unit - For UPS Room Nos. 2
f 2.0 TR Slim Duct FCU Nos. 7
g 1.5 TR Slim Duct FCU Nos. 4
h 1.3 TR Slim Duct FCU Nos. 1
i 0.8 TR Slim Duct FCU Nos. 15
j 0.6 TR Slim Duct FCU Nos. RO
1.6 SITC of corded remote / thermostat for Indoor Units Nos. 31
1.7 Additional Charge of gas and oil for VRF units Lot 1
1.8 Central Remote controller for VRV Units. Nos. -
1.9 Sequential Controller for AC unit to programme the run hours of compressor.
a For Server & UPS Room Nos. 2
TOTAL OF HIGH SIDE -
HVAC HIGH SIDE
SR.NO DESCRIPTION UNIT QTY RATE AMOUNT
1.0 EQUIPMENTS
1.1
Supply, installation, testing & commissioning of DOUBLE SKIN, CEILING SUSPENDED AHU, with supply air
aluminium damper, sectionalized construction, draw through type air handling unit (AHU) of 0.8mm thk GI sheet metal
cabinet type (outer skin) & 0.8 mm thk GI PLAIN (inner skin) and imported fans equipped with 50 mm thick, 40 kg/cum
polyurethane foam sandwiched between panels complete with pre filter of MERV 8-90% efficiency down to 10 microns
with Fan section with DIDW centrifugal forward / backward curved fan of non-overloading characterstics & Motor (IE2)
shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply, Multi Row coil section with copper header,
removable type Cooling coil section, insulated SS drain pan of double wall construction with 13 mm thick nitrile foam
insulation.
NOTE : THE UNIT NOISE LEVEL SHOULD NOT EXCEED 55 DB.
EACH UNIT SHOULD BE PROVIDED WITH THE GI TRAY BOTTOM OF THE UNIT, COVERING VALVES & DRAIN
OUTLET
Contractor shall design the chilled water coil according to the following conditions:
a. ADP - 13 +/- 1.0 deg C
b. Chilled water temperature entering 7.5 deg C/ 45.5 deg F
CFM TR Ex.SP TYPE
a) 7000 cfm, 18TR 25mm (Ceiling Suspended) Nos. 1
b) 1000 cfm 2.5TR 15mm (Ceiling Suspended) Nos. 1
c) 4000 cfm 10 TR 25mm (Ceiling Suspended) Nos. 1
Note: Fan Outlet Velocity 8 m/sec
Coil face velocity 2.5 m/sec
Filter velocity 2 m/sec
TOTAL OF AHU -
AHU
ITEMS MAKE / BRAND / SPECIFICATION INTERIOR
1 Ply wood "ISI" marked brands such as ANCHOR/KIPLY/SAMRAT
2 Wood For Frame Work 2" X 1 1/2" thk.Sal wood ( Seaeoned ) with 2 coat of wood preservative.
3 Wooden Skirting/Molding,Lipping/Beading T.W ( BG Grade)
4 BWP Ply / Block Board True Wood
5 Laminate 1.00mm thk. Greenlam or Merino / century / royal/ national / euro/bloom
6 0.08MM THK laminate Local make for internal use of storages
7 Venner As selectd by Architect / Client / euro / green /anchor /samrat
8 Adhesive Fevicol SH ( Pidilite)/ jivanjor
9 Door Closer Hemco/Enox /Dorma/Ozone/STANLEY,equivalent
10 Floor Spring Hemco/Enox /Dorma/Ozone/STANLEY,equivalent
11 Door Lock Godrej / Doorset or Equivalent
12 Drawer Lock Godrej / Doorset or Equivalent
13 Sun control Flim Graware / Llumar / 3 M
14 Soft Board / Display Jolly Board
15 Paints Asian / Berger /NIPPON/ Nerolac
16 Ceramic Tiles Nitco/ Somany/ Kajaria/JOHNSON/Asian/ swastik tiles / elica / veritaas
17 Vitrified Tiles Nitco/ Somany/ Kajaria/JOHNSON/Asian/ swastik tiles / elica / veritaas
18 POP on walls Dimond POP/ Rajsthan super white
19 Glass Modi Guard / Saint Gobain /Asahi
20 G.I Pipes for plumbing Tata ,Jindal
21 PVC / CPVC/ UPVC Pipes Prince / finolax / astral
22 WC JAQUAR / HINDWARE / parryware
23 Sensors Urninal ( post use flusihing ) JAQUAR /HINDWARE /ASKON
24 Sainatary Fixture JAQUAR / HINDWARE / parryware
25 Hand Dryer Askon, JAQUAR
26 Soap Dispencer Kimberly -Clark, PARK/ jaquar
27 C Fold tissue paper Holder Kimberly -Clark, PARK/ jaquar
28 Roller Blind MAC/VISTA/EQUIVALLENTS/GALEECHA/bharat furnishing
29 Glass wool UP Twiga, Minwool
30 Cement Ultratech,Ambuja, ACC, JK
31 Gypsum Ceiling sheets India Gypsum / lafarg india / elephant / saintgobin
32 False ceiling frames / sections JSW/ Essar steel / Dimond frames
33 Modular Ceiling ARMSTRONG / AMF /USG / SAINTGOABIAN
34 Glue Fevicol
35 Screws GKW
36 SINK Nirali
37 NYLON CARPET MILIKEN/ INTERFACE/ CCIL/ MR/ MODULESS
ITEMS MAKE / BRAND / SPECIFICATIONELECTRICAL
1 Access Control System HID/GE/HONEYWELL/JOHNSON CONTROLS
(Attendance cum access control)
2 CABLES POLYCAB / HAVELL'S / RR KABEL / KEI / ANCHOR
3 CONTROL FUSES L & T, SIEMENS, MERLIN GERIN
4 CONTROL SWITCHES KAYCEE.
5 CTS & PTS AE / INDCOIL.
6 DECORATIVE FITTINGS PHILIPS / TROLL / ABBY
7 Light Fixtures PHILIPS / PANASONIC / WIPRO /TULIP / ARRYSTORM
8 ELCB / ELMCB Siemens
9 Flexible conduit ISI
10 Glands Braco
11 HRC FUSES & FUSE BASE L & T, SIEMENS.
12 INDICATING LAMPS TECHNIC / CONCORD.
LIST OF MAKE
13 Industrial Socket outlet Siemens
14 Lugs Dowells
15 MCBS & DB LEGRAND / SCHNEIDER / SIEMENS / MERLIN GERIN
16 PVC CONDUITS & ACCESSORIES PRECISION.
17 Structured Cabling AMP/SYSTIMAX/3M
18 SWITCH - SOCKET L&TCRABTREE
19 SWITCHES L & T, SIEMENS.
20 TELEPHONE WIRES / CABLES. DELTON, POLYCAB / FINOLEX / HAVELL'S / DLINK / TYCO AMP
21 TERMINALS ELEMEX / ESSEN.
22 WIRES POLYCAB / HAVELL'S / RR KABEL / KEI / ANCHOR
23 PA System Philips / Ahuja/BOSCH
SECURITY AND FIRE SAFETY MAKE / BRAND / SPECIFICATION 1 Fire sprinkler MS Pipes Class C As per IS 1239
2 Fire Alarm system Zicom / GE / HONEYWELL / MORLEY /APOLLO/EST
3 CCTV HONEYWELL/ HIKVISION / DHAWA/ CP PLUS
4 Fire Extinguisher Cease Fire /CROSSFIRE/SAFAX
5 Access Control HID /GE/HONEYWELL/ NITGEN
ITEMS MAKE / BRAND / SPECIFICATION
HVAC1 Cables Polycab /KEI / RR CABLES
2 Damper COSMOS /Air Flow, or eq. ISI MARK
3 G I Sheets Jindal, Essar, Uttam or eq.
4 4 Grills/Diffusers Air Flow, or eq. COSMOS/ Air Flow, or eq. ISI MARK
5 Insulation material. Owens Corning, U P Twiga, Kimco / KFLAX
6 AHUs ZECO / BLUESTAR / VOLTAS/ VTS
8 Split Units BLUE STAR/ LG/ VOLTAS /MITUBUISHE
MODULAR FURNITURE MAKE / BRAND / SPECIFICATION WORKSTATION DANCO /SPACEWOOD
STORAGES DANCO /SPACEWOOD
COMPACTORS SPACE PLANNERS
CHAIRS AMARDEEP/LILA DÉCOR