What Makes the SSI ECT 70 T ube Diffuser s a world wide choice ? SSI’s ECT70 tube diffusers are designed to offer high oxygen transfer efficiency, low pressure loss, and a simple installation. Our new ECD70 diffusers are available with a variety of membrane materials including our patented PTFE membranes, designed to use less energy and require minimal maintenance. Strong Polypropelyene body makes handling during installation easy, provides temperature resistance up to 190 0 F (90 0 C), and is environmentally friendly. ECT diffusers feature a channel style support body which extends membrane life in on/off applications. SSI ECT70 Tube Diffuser 4 Tucker Drive Poughkeepsie, New York 12603 USA www.sssiaeration.com tel: +1 (845) 454-8171 email: info@ssiaeratio n.co m fax: +1 (845) 454-8094 l o 85" (2165mm) B 2165
Transcript
Page 1: SSI ECT 70 Tube Diffusers · ECT di˜user functions similar to a panel di˜user resulting in a higher SOTE rate. Intelligent Upgrade Options P SSI’s patented PTFE membrane barrier

What Makes the SSI ECT 70 Tube Diffusersa world wide choice ?SSI’s ECT70 tube diffusers are designed to offer high oxygen transfer efficiency, low pressure loss, and a simple installation. Our new ECD70 diffusers are available with a variety of membrane materials including our patented PTFE membranes, designed to use less energy and require minimal maintenance. Strong Polypropelyene body makes handling during installation easy, provides temperature resistance up to 1900 F (900 C), and is environmentally friendly. ECT diffusers feature a channel style support body which extends membrane life in on/off applications.

SSI ECT70 Tube Diffuser

4 Tucker DrivePoughkeepsie, New York 12603 USAwww.sssiaeration.com tel: +1 (845) 454-8171email: info@ssiaeratio n.co m fax: +1 (845) 454-8094

lo

85" (2165mm)

B

2165±

Page 2: SSI ECT 70 Tube Diffusers · ECT di˜user functions similar to a panel di˜user resulting in a higher SOTE rate. Intelligent Upgrade Options P SSI’s patented PTFE membrane barrier

Unique System StrengthsComplete product line – creating the system that �ts your needs

, tube di�user ,products on a wide range of piping materials including PVC, CPVC, PP and Stainless steel. We have

provide retrievable systems or �xed grids, and systems in kit form or mostly factory assembled. We try to understand and anticipate your needs, and �t our recommendations to your situation.

Piping system integrity – thicker wall pipe and double anchors for fewer breakages Our piping is 38% thicker and has double rod support stands as standard – two anchors for each support

temperature and water velocity. SSI locates two anchors where support is needed most, helping to increase product longevity.

SSI provides full design services, including biological and mixing calculations, process simulations and

assist with speci�cations and CAD drawings. Our service and installation crew can hold your hand during

satisfaction.

SSI ECT70 Tube

www.s siaeration .com

Why choose the SSI ECT Di�user?SSI developed the ECT tube di�user to bring a quality tube di�user at an a�ordable price to the wastewater market. In low air�ow rates the bottom part of a conventional 360 di�user is inactive. The ECT di�user functions similar to a panel di�user resulting in a higher SOTE rate.

Intelligent Upgrade OptionsP SSI’s patented PTFE membrane barrier properties not only reduce plasticizer extraction, shriking, and membrane hardening but also limit dynamic changes that can result from swell, such as creep. Compared with uncoated products that are more susceptible to increases in DWP due tomore aggressive fouling and changes in physical properties and weight, the PTFE coated membrane improves consistency of DWP (Headloss) values over the product life. This directly impactslong-term power costs and the ability of the system to distribute air uniformly across the tank �oor.

Per Meter Per Meter

Average Operating Conditionper Meter

Flow Range of Di�user per Meter

Active Surface Area per Meter

Weight per SetECT70

1 - 8 SCFM1.7 - 13.5 Sm3/hr

0 - 12 SCFM0 - 20.4 Sm3/hr

1 ft2

0.1m26.3 lbs3.7kg

* All di�users can operate at low �ow rates close to zero in such conditions air distribution may not be uniform at higher rates fouling are possible so routine bumping / �exing may be appropriate.

toofer

%p

TEOS

mer

%p

TEOS

eter

1.5 3.5 5 7 8.5 10 12 13.5 15 17 18.5

1 2 3 4 5 6 7 8 9 10 11

Heshc

ins

-s

lodea

H.G

.W

mm

s -

slo

ead

70

60

50

40

30

20

10

0

1780

1520

1270

1015

760

510

255

0

1 2 3 4 5 6 7 8 9 10 11

1.5 3.5 5 7 8.5 10 12 13.5 15 17 18.5

2.5

2.0

1.5

1.0

0.5

0

10.5

9.5

8.0

6.5

5.0

3.0

1.5

0.0

Conventional Tube vs ECT Tube Di�usersSSI’s ECT di�user is capable of producing a higher SOTE compared to conventional tube di�users. ECT di�users are more e�ective at lower air�ow rates when conventional tubes would only be partially activated.


Recommended