STARDEX SISU 2016 USER INTERFACE DESCRIPTION, INSTRUCTION MANUAL As all other Stardex products, our software we create by ourselves. We like it and we are sure - you will also like our convenient, intuitive, easy to use and reliable interface. All Stardex original software was and will be free for our clients. No fees for updates or prolongation of the license. All updates are available on our website free. STARDEX OY LTD HELSINKI, FINLAND 2016 www.stardex.fi
Transcript
Page 1: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX SISU 2016 USER INTERFACE

DESCRIPTION, INSTRUCTION MANUAL

As all other Stardex products, our software we create by ourselves. We like it and we are sure - you will also like our convenient, intuitive, easy to use and reliable interface.

All Stardex original software was and will be free for our clients. No fees for updates or prolongation of the license. All updates are available on our website free.

STARDEX OY LTD

HELSINKI, FINLAND 2016

www.stardex.fi

Page 2: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

2 STARDEX LTD OY FINLAND

Table of contents

Chapter Title Page

What’s new 3

Sections 4

Main Section 5

The Test Bench Management Section 8

The Regulators Control Section 10

The Injectors Control Section 11

Categories of the additional section: „FLOW”

12

“CODING” 13

“PUMP” 14

“VOLTAGE” 15

“DELAY” 16

“INFO” 17

“SETTINGS” 18

“REPORT” 19

Pump testing 20

Injector testing 22

Page 3: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 3

What’s new

Universal user interface for simulators STARDEX 0304, 0305, 0402, DIMAS

Compatible with flow meters STARDEX 0102, 0103, 0104

Compatible with test bench STARDEX 0803 и STARDEX DIMAS

Support of STARDEX 0502

Improved support of widescreen monitors

Wide range of screen resolutions from 1024x768 to Full HD

Simple operation that facilitates the work for beginners

Extensive additional functionality for advanced users

Extended tips for each component

Multi-language support

The ability to insert the test report, company logo and details

Save the report in PDF format

Improved support of color printers

A huge database of CR injectors and pumps of the world's major manufacturers

Easily create your own test plans from a template or from scratch

Ability to create and save your own current-voltage profiles

Free software with free and easy to install updates for all users of STARDEX

Delphi C2I, Bosch IMA and Denso coding

A lot of useful additional information

Page 4: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

4 STARDEX LTD OY FINLAND

Sections

1. The main section.

2. The test bench management section.

3. The high-pressure control section.

4. The injectors control section.

5. Additional section.

6. Status bar.

Page 5: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 5

Main section

Pumps Test Mode Injectors Test Mode

Manufacturers

Number of

Manufacturer or OEM

Filter

Selected product

Coding mode

Semi-automatic test

mode

Manual test mode

Auto test mode

List of tests

Save readings of flow

meter

Resetting the flow

meter

Save the test plan

Create the test plan

Print a report

Add / Remove test

Changing the test plan

Enable timing

Stabilization time

Measuring time

Start/Stop

Page 6: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

6 STARDEX LTD OY FINLAND

Work on the device starts with the main section. Here, the user first determines what

will be tested - the pump or injector. Then, he chooses the manufacturer and serial

number. For a quick search in our database, you can use the filter. It is enough to

enter a part of the serial number and the list of relevant results will be displayed.

TESTING THE INJECTORS COMMON RAIL:

When choosing injectors, the system, using the number, determines itself, which,

electromagnetic or piezoelectric injector is selected by the user, and activates the

corresponding indicator (coil or piezo) in the injectors control section.

Selecting the test mode.

With manual testing “MANUAL” - the user sets all test parameters itself. In this

mode, there is no test plan and there is no report on the results of testing. Current-

voltage characteristics of the control signal for the injectors are installed by default

from the database. This mode is recommended for advanced users only.

In semiautomatic mode “TESTPLAN” - the user makes the test, following the test

plan. In each step of the test, all the set and measured parameters are preset.

Navigating the tests carried out in the list of tests. The user has the ability to modify

most of the settings on his own.

In the automatic mode “AUTO” - the user does not have the ability to change test

parameters, and navigate through the tests. All the tests automatically go from the

beginning to the end without any participate of the operator.

Coding mode “CODING” is similar to the automatic test mode, but it involves a lot

more tests and therefore takes more time. At the end of the process, in the

additional section, in the «Coding» section will be new repair injector codes.

The buttons «New» «Edit» «Save» «+» «-» are used by advanced users to create

their own test plans.

«Store» button saves the current value of the supply or return flow into the report.

«Reset» button resets the current supply or the return value of the drain and allows

to start re-flow measurement at any time. If the timer is activated by checking the

Page 7: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 7

appropriate box, then injectors performance measurement will be strictly on time.

During the stabilization the user is given the opportunity to estimate the flow, but

the final accurate measurement will be displayed and automatically saved in the

report only at the end of the measurement time. Using the timer increases the

accuracy and repeatability of test results.

«Print» button opens an additional window, in which you can print out the test

results, save the report to PDF, change the company logo and details on the form,

enter the customer's data.

Button «Start / Stop» is used to start / stop the test in Auto and Coding mode. In

Manual and Test-plan mode, the start/stop button enable / disable the motor control

section (only when working with a test bench Stardex), regulators and injectors.

Sections are turned on one by one. The injectors are activated upon reaching a

predetermined pressure.

Page 8: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

8 STARDEX LTD OY FINLAND

Test bench Management Section

This section is available for users of complexes on the basis of the test benches

STARDEX 0801, 0802, 0803 и STARDEX DIMAS.

Here is a motor control and test bench's supply pump control, as well as control of

the temperature and pressure in the arteries of the test bench, the level of fuel in the

tank and the cooling fans control.

Before starting the work on the test bench, you must install the motor rotation

direction (left / right) in accordance with the established pump in the test bench.

And turn on the supply pump or switch it in automatic mode.

To activate the supply pump it is needed to press on supply pump indicator, pressing

it again will lead to the switching the supply pump to the automatic mode. Another

press will turn off the supply pump. In automatic mode, the supply pump turns on

simultaneously with the start of rotation of the test bench engine.

Left / Right

rotation

The

target

speed

Temperature

sensor 2

readings

Pressure

sensor 1

readings

Temperature

sensor 1

readings

Pressure sensor

2 readings

Indicator of

the fans

Charge pump

indicator

The fuel

level in the

tank

Actual speed

On / Off

section

Page 9: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 9

To start test bench motor rotation, press on/off switch of the section, or START

button in the main section. The engine seamlessly picks up the target speed. To stop,

press on/off switch of the section or STOP.

Page 10: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

10 STARDEX LTD OY FINLAND

The pressure regulators control section

In this section is the management of pressure regulators. Current tire pressure is also

displayed here.

If the regulator is activated, at inclusion of the section, the signal needed to achieve

the target value will be sent. The target value may be amperage, duty cycle, the

pressure.

The target

pressure Amperage

Duty cycle Activation of the

regulator 1

Amperage

Duty cycle

Activation of the

regulator 2

Activation of the

regulator 3

Current

pressure

On / Off

sections

Page 11: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 11

The injectors management section

In this section the user controls the injectors.

The signal at the injector is characterized by length, frequency, and voltage-current

profile. It is important not to be mistaken with the type of tested injectors. In the

piezo-regime, the voltage is very high and can damage the injector with solenoid

valve!

It is very easy to check the type of injector. You need to measure the resistance

between the injector contacts with a tester. The resistance of the solenoid valve is no

more than several Ω Ohms. The piezo resistance is over several hundred Ω KOhms.

To get started, activate necessary injectors by clicking on the corresponding

numbered LEDs. When you press the power button section, the signal will be fed to

the activated injectors.

Pulse

length

Pulse

frequency

Injectors type

indicators

Injectors work

indicators

On / Off

sections

Page 12: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

12 STARDEX LTD OY FINLAND

Additional section. Measuring injectors delivery.

This section serves to measure delivery and backflow of injectors.

When using STARDEX 0102, 0103, 0104, 0305, DIMAS, the measurements will be

made automatically. If the e-measuring system is not present, then the measurement

should be carried out in glasses, and the results must be entered directly in the flow

value field. For the convenience of working at different measuring systems and test

benches, units can be changed from mL/min to mL/100 cycles, mL/200 cycles,

mL/1000 cycles, l / h.

If Test-plan mode or Auto mode selected, upper and lower flow limit for this test will

be displayed on the glasses.

Units of delivery

measurement

Upper

limit

Units of backflow

measurement

Lower

limit

Delivery

value

Delivery

value

Page 13: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 13

Additional section. Coding.

Upon completion of the encoding process, new repair codes can be viewed in this

section.

Injectors coding function is available only with an electronic measuring system

STARDEX 0102, 0104, 0305, DIMAS!

Repair injectors codes

Page 14: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

14 STARDEX LTD OY FINLAND

Additional section. Pump delivery flow meter.

This section serves to measure pump delivery and backflow.

When using STARDEX 0102, 0103, 0104, 0305, DIMAS, the measurements will be

made automatically. If the e-measuring system is not present, then the measurement

should be carried out in glasses, and the results must be entered directly in the flow

value field. For the convenience of working at different measuring systems and test

benches, units can be changed from mL/min to l / h.

In the information field is the description of the procedures and test parameters.

Units of delivery

measurement

Units of backflow

measurement

Delivery

value Backflow value Information field

Page 15: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 15

Additional section. The graph of amperage and voltage-current

characteristics of the signal.

Injectors current graph serves as an additional tool for the analysis of injector failure.

Abnormal graph may indicate shorted turns in the electromagnet or breakdown of

injector's piezo element.

On the right are the basic parameters of the current-voltage profile. Signal voltage,

the first and second phase current value (the pushing and holding phase), and the

first phase duration in microseconds. Change of the profile settings is recommended

for advanced users only. In rare cases, incorrect values of currents and voltages can

cause failure of the injector or simulator!

Current of first phase

Length of 1 phase Voltage

Current of second phase Set defaults

Current graph

Page 16: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

16 STARDEX LTD OY FINLAND

Additional section. Injection delay.

This function is active, when using our devices Stardex Dimas or Stardex 0502. By the

end of the test in these fields injection delay in microseconds (μs) appears.

Page 17: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 17

Additional section. Information.

Additional information section may include information about the applicability of the

product, cross references, number of spare parts, as well as information on the

assembly moves, dimensions and clearances.

For the majority of Bosch injectors, there is a detailed description of the location and

purpose of shims. This window is opened by clicking the Show details button.

Page 18: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

18 STARDEX LTD OY FINLAND

Additional section. Settings.

As a rule, a user enters settings a time, when he first sets up the device.

Pressure sensor type should be selected according to the pressure transducer

mounted on the fuel rail.

The regulators configuration is necessary to establish the amount of pressure

regulators used in accordance with the simulator. Their amount may be from one to

three.

In the configuration, you must install the injectors number, in accordance with the

simulator, you use. Their number can be from one to six.

The main language in the program is English, but the tooltips for the components can

be displayed in different languages. Simply select the desired language from the

corresponding list.

Pressure sensor

type

Autoreset Fast coding

Regulators

configuration

Language of tooltips

Injectors

configuration

Page 19: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 19

Additional section. Report.

During the injectors test in the Auto or Test-plan mode, or during the pump test, the

report on the results is formed.

The report contains the names of the tests, the permissible ranges of values and

values, obtained from tests.

Page 20: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

20 STARDEX LTD OY FINLAND

Pump test

Connection example for STARDEX 0803 + STARDEX 0304 + STARDEX 0104

Set Common Rail system pump and fuel rail as shown in the diagram above at the test

bench. Connect test bench STARDEX 0803 and STARDEX 0104 flow meter by USB cable

to the simulator STARDEX 0304. In STARDEX SISU program, select the manufacturer

and serial number of the tested pump. Install the direction of rotation of the pump in

accordance with the set pump, in the program. Switch charge pump in Auto mode or

ON mode. On an additional panel, go to the "Pump" section and follow the instructions

in the information field.

Page 21: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 21

To begin testing, you need to select a test and then click "Start" in the main section. To

save the test results to the report, click "Store" button in the main section.

Printing a report, saving to PDF, entering company data and customer data is carried

out in an additional window that appears when you press the "Print" button in the

main section.

When working on a test bench with high pressure, it is needed to use protective

cover, to prevent human injury in case of emergency situations!

Page 22: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

2016 STARDEX GUI | NEW FEATURES |ENG

22 STARDEX LTD OY FINLAND

Injectors test

Connection example for STARDEX 0803 + STARDEX 0304 + STARDEX 0104

Set Common Rail system pump and fuel rail and tested injectors as shown in the

diagram above at the test bench. Connect test bench STARDEX 0803 and STARDEX

0104 flow meter by USB cable to the simulator STARDEX 0304. In STARDEX SISU

program, select the manufacturer and serial numbers of the tested injectors. Choose

the test mode. Install the direction of rotation of the pump in accordance with the set

pump, in the program. Switch supply pump in Auto mode or ON mode.

Activate the connected injectors, according to the numbered cable. Open the "Flow"

section in the additional section. Press "Start" in the main section.

Page 23: STARDEX SISU 2016 USER INTERFACE · 2019. 9. 23. · Free software with free and easy to install updates for all users of STARDEX Delphi C2I, Bosch IMA and Denso coding A lot of useful

STARDEX GUI | NEW FEATURES |ENG 2016

STARDEX LTD OY FINLAND 23

In AUTO or CODING mode, tests will be carried out from the beginning to the end,

one by one, without user intervention. At the end of the process, it will generate a

report or new injectors' codes.

In TESTPLAN mode, the user chooses tests from a list and launches them. Test results

are stored in the report by pressing the STORE button or automatically at the end of

the "Measuring time".

Manual mode is only for experienced users who know what they are doing and why.

It is used to make exotic test conditions. Saving the results in a report is not available.

Printing a report, saving to PDF, entering company data and customer data is carried

out in an additional window that appears when you press the "Print" button in the

main section.

When working on a test bench with high pressure, it is needed to use protective

cover, to prevent human injury in case of emergency situations!


Recommended