Attributes Advantages
1. Semi-concealed fastener panel 1. Attractive architectural application2. Unique side lap feature 2. Conceals panel side laps for aesthetically
pleasing appearance3. Continuous eave to sill to 32' length 3. Eliminates end laps and improves appearance4. Fire Rating 4. The panel is classified by UL® for 1 & 2 hour
fire resistance 5. Signature® 200 Colors 5. 25-year finish warranty6. Signature® 300 Colors option 6. 25-year premium paint finish warranty with
ultimate resistance to chalking and color changes
Gauge 26 gauge (standard) 24 gauge
LengthMaximum length of 32'-0"
Dimensions36" wide by 1" high
Usage Wall panel, liner panel and façade panel
Finish Galvalume Plus® Signature® 200 Colors Signature® 300 Colors
Fasteners Semi-concealed, self drilling fasteners, long life coated to match wall color
DescriptionStarMark is a functional 36" wide wall panel that provides aesthetics and cost efficiency. An architecturally sculptured shadow panel is achieved with 1" deep ribs to help conceal fasteners. Major corrugations on 12" center not only provide panel strength and integrity, they enhance the panel’s aesthetically pleasing sculptured look as well.
StarMark Wall System
Roof and Wall
Systems
Standing Seam
Roof Systems
Insulated Panel System
s
The engineering data contained herein is for the expressed use of customers and design professionals.
Along with this data, it is recommended that the design professional have a copy of the most current
version of the North American Specification for the Design of Cold-Formed Steel Structural Members
published by the American Iron and Steel Institute to facilitate design. This specification contains the
design criteria for cold-formed steel components. Along with the specification, the designer should
reference the most current building code applicable to the project jobsite in order to determine
environmental loads. If fur ther information or guidance regarding cold-formed design practices is
desired, please contact the manufacturer.
EFFECTIVE JULY 22, 2010SUBJECT TO CHANGE WITHOUT NOTICE
Galvalume Plus® is a registered trademark of BIEC International, Inc.
Signature® is a registered trademark of the NCI Group.
Properties Notes:1. Section proper ties have been calculated
in accordance with the 1986 AISI Cold-Formed Specification with 1989 addendum.
2. Steel thickness was used in determining section properties. Coated thickness includes galvanized or zinc-aluminum coating.
Allowable Uniform Loads Notes:1. Top values are based on stress.
¹/3 for wind load is included.
2. Bottom values are based on deflection of L/120 for 10 year wind (L/90 for 50 year wind).
3. Standard fastener pullover allowable is 222 lbs. including 1.3 increase for wind (#12 fastener without washer).
Allowable Load (PSF) For Nominal Purlin Spacing
StarMark - Section Properties
StarMarkWall System
NEGATIVE BENDING POSITIVE BENDING
PANEL GAUGE
Ap (IN2/FT.)
G' (#/IN.)
Ix (IN.4/FT.)
Sx (IN.3/FT.)
Ix (IN.4/FT.)
Sx (IN.3/FT.)
Fb (KSI)
26 0.752 0.03748 0.05073 0.03552 0.05763 30
24 0.927 0.04551 0.06160 0.04313 0.06998 30
26 Gauge
SPANTYPE
LOADCONDITION
PURLIN SPACE
5' 6' 7'
SIMPLE
PRESSURE 54.0052.42
37.5030.34
27.5519.10
SUCTION 61.3549.68
42.6028.75
31.3018.10
2-SPAN
PRESSURE 61.35123.09
42.6071.23
31.3044.86
SUCTION 54.00123.09
37.5071.23
27.5544.86
3-SPAN
PRESSURE 76.6996.33
53.2555.75
39.1335.10
SUCTION 67.5096.33
46.8855.75
34.4435.10
24 Gauge
SPANTYPE
LOADCONDITION
PURLIN SPACE
5' 6' 7'
SIMPLE
PRESSURE 65.5863.65
45.5436.83
33.4623.20
SUCTION 74.5060.32
51.7334.91
38.0121.98
2-SPAN
PRESSURE 74.50149.46
51.7386.49
38.0154.47
SUCTION 65.58149.46
45.5486.49
33.4654.47
3-SPAN
PRESSURE 93.12116.97
64.6767.69
47.5142.63
SUCTION 81.97116.97
56.9267.69
41.8242.63