2829
2021
20 21
17 16
N 1/2 OF NE 1/4
S 1/2 OF NE 1/4
LESSW 261'
NE 1/4NW 1/4SE 1/4
N 1/2NE 1/4SE 1/4
S 1/2NE 1/4SE 1/4
SE 1/4SE 1/4
SE 1/4NW 1/4SE 1/4
E 1/2NE 1/4SW 1/4SE 1/4
SW 1/4NW 1/4SW 1/4
NW 1/4SW 1/4SW 1/4
NE 1/4SW 1/4SW 1/4
N 1/2NW 1/4SW 1/4
SE 1/4NW 1/4SW 1/4
S 1/2SW 1/4SW 1/4
N 1/2NW 1/4NW 1/4
N 44' OF S 12 OF NW 14 OF NW 1/4
PROPOSED 660' SETBACK
FOR EAGLE NEST AREA
APPROXIMATE LOCATION
EXISTING EAGLE NEST AREA
PROPOSED
PROJECT SUBSTATION
ER2
AR5
AC
AR5
AC
AC
AR
AR
AR
DC
DC
PROPOSED
SITE ENTRANCE/DRIVEWAY
AR
AR
R1
R2
AR
R4
DC
PROPOSED
SITE ENTRANCE/DRIVEWAY
FRAZEE HILL ROAD
BLA
NT
ON
R
OA
D
RUFFING ROAD
RA
MS
EY
R
OA
D
PLATT ROAD
BLA
NT
ON
R
OA
D
S
T
A
T
E
R
O
A
D
4
1
E E E
EE
EE
EE
E
E E
X
X X
XX
XX
XX
X
XXX
XX
XX
X
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
25' BUFFER
PER LANDSCAPE PLAN
PROPOSED
25' BUFFER
PER LANDSCAPE PLAN
PROPOSED
25' SETBACK
PROPOSED
50' SETBACK
PROPOSED
50' SETBACK
PROPOSED
25' SETBACK
PROPOSED
50' SETBACK
PROPOSED
25' SETBACK
PROPOSED 50' SETBACK
EEEE
E
X
X
X
X
XX
X
XX
X
X X X X X
XX
X
X
XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
PROPOSED
15' BUFFER
PER LANDSCAPE PLAN
PROPOSED
15' SETBACK
PER LANDSCAPE PLAN
PROPOSED
25' BUFFER
PER LANDSCAPE PLAN
PROPOSED
50' SETBACK
PROPOSED
37' MIN. SETBACK
FOR SUBSTATION FENCE
PROPOSED
62' MIN. SETBACK FOR SUBSTATION FENCE
EXISTING
69 kV GENERATION TIE-LINE
C:\U
sers\F
S104849\M
ountain V
iew
\P
D-100-S
P - 032318.dw
g F
S104849 M
ar 23, 2018 - 4:13pm
©
FIRST SOLAR, INC.
135 MAIN STREET, 6TH FLOOR
SAN FRANCISCO, CALIFORNIA 94105
PHONE: (415) 935-2500
WWW.FIRSTSOLAR.COM
MO
UN
TA
IN
V
IE
W S
OLA
R
R
NORTH
11
PROJECT BOUNDARY
EXISTING 69 kV GENERATION TIE-LINE
PROPOSED PERIMETER ROAD
PROPOSED PERIMETER FENCE
X
PROPOSED PV ARRAY
PROPOSED 25' WIDE LANDSCAPE BUFFER
PROPOSED TEMPORARY
CONSTRUCTION STAGING AREA
EXISTING DELINEATED WETLANDS W/ 25 FEET SETBACK
PROPOSED 15' WIDE LANDSCAPE BUFFER
PROPOSED GEN-TIE
E PROPOSED 34.5 kV UNDERGROUND COLLECTION LINE
NOTES
LEGEND
PROPOSED SETBACK
1. NOT FOR CONSTRUCTION.
2. SITE CAPACITY, ARRAY CONFIGURATION, PERIMETER FENCE ALIGNMENT,
INTERNAL ROAD DESIGN, ETC. TO BE DETERMINED DURING DETAILED
DESIGN.
3. THE PROJECT SHALL HAVE NO IMPACT TO WETLANDS AND SHALL COMPLY
WITH THE MINIMUM 25' WETLAND SETBACK IN ACCORDANCE WITH THE
REQUIREMENTS OF THE FDEP AND PASCO COUNTY.
4. 6' FENCING FOR ENTIRE SITE TO BE LOCATED INSIDE OF LANDSCAPING.
5. NO CURRENT OR FUTURE DEVELOPMENT WITHIN THE EAGLE NEST SETBACK.
6. LIGHTNING MAST AND ADDITIONAL UTILITY EQUIPMENT WITHIN THE
SUBSTATION SITE MAY HAVE A TOTAL HEIGHT GREATER THAN 15 FEET.
ADDITIONAL SETBACKS TO SUBSTATION FENCING SHALL BE PROVIDED AS
SHOWN, PER PASCO COUNTY LAND DEVELOPMENT CODE, SECTION 530.
7. NO STRUCTURES OUTSIDE OF THE SUBSTATION BOUNDARY WILL HAVE A
HEIGHT GREATER THAN 15 FEET.