Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology 4 February 2003
Transcript
Page 1: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Statistical analysis of cardiac activity and processes

maintaining human stability using force plate

Jan Kříž

Kochi University of Technology 4 February 2003

Page 2: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Program of the seminar

• What is the force plate? • Postural control • Cardiac activity and hemodynamics• Known results

• Mathematical models of postural control• Our approach• Illustration of data analysis• Conclusions

Page 3: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

What is the force plate?

4 load transducers

piezoelectric (Kistler)

strain gauge (Bertec)

Data are mixed by Wheatstone bridges

6 signals

linear cross talks => calibration matrix

Page 4: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

What is the force plate?

Only 5 independent signals

Fx , Fy ... shear forces

Fz ... vertical force

x = - My / Fz

... coordinates of COP

y = Mx / Fz

Page 5: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Postural Requirements

• Quiet standing

- support head and body against gravity

- maintain COM within the base of support

Page 6: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Postural Control Inputs

• Somatosensory systems

- cutaneous receptors in soles of the feet

- muscle spindle & Golgi tendon organ information

- ankle joint receptors

- proprioreceptors located at other body segments• Vestibular system

- located in the inner ear

- static information about orientation

- linear accelerations, rotations in the space• Visual system

- the slowest system for corrections (200 ms)

Page 7: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Motor Strategies

- to correct human sway

- skeletal and muscle system• Ankle strategy

- body = inverted pendulum

- latency: 90 – 100 ms

- generates vertical corrective forces

Page 8: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Motor Strategies

• Hip strategy

- larger and more rapid

- in anti-phase to movements of the ankle

- shear corrective forces

• Stepping strategy

Page 9: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Postural Control

- central nervous system• Spinal cord

- reflex ( 50 ms )- fastest response - local

• Brainstem / subcortical- automatic response (100 ms)- coordinated response

• Cortical- voluntary movement (150 ms)

• Cerebellum

Page 10: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Why to study the postural control?

• Somatosensory feedback is an important component of the balance control system.

• Older adults, patients with diabetic neuropathy ... deficit in the preception of cutaneous and proprioceptive stimuli

• Falls are the most common cause of morbidity and mortality among older people.

Page 11: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Cardiac activity and hemodynamics

Page 12: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Cardiac activity and hemodynamics

Hemodynamics = dynamics of blood circulation

- forces generated by heart and resulting blood motion

Page 13: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Cardiac activity and hemodynamics

Total blood circulation:

veinsr.atriumr.ventriclepulmonary a.lungspulmonary v.l.atriuml.ventricleaortabranching to capillares veins

Page 14: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Cardiac activity and hemodynamics

Page 15: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Known results

• Measurements• quiet standing (different conditions, COP

displacements, Fz – cardiac activity, relations between COP and COM)

• perturbations of upright stance ( relations between the perturbation onset and EMG activities)

• Results• two components of postural sway (slow 0.1 – 0.4 Hz,

fast 8 –13 Hz; slow ~ estimate of dynamics, fast ~ translating the estimates into commands)

• corrections in anterio-posterior direction: ankle; in lateral direction: hip

Page 16: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Known results

• suppressing of some receptors -> greater sway• stochastic resonance: noise can enhance the

detection and transmission of weak signals in some nonlinear systems ( vibrating insoles, galvanic vestibular stimulation)

• Models of postural sway• Inverted pendulum model • Pinned polymer model

Page 17: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Inverted pendulum modelEurich, Milton, Phys. Rev. E 54 (1996),

6681 –6684.

I’’ + ’ – mgR sin f(t-

m ... mass

g ... gravitational constant

I ... moment of inertia

... damping coefficient

... tilt angle (=0 for upright)

f ... delayed restoring force

R ... distance of COM

Page 18: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Pinned polymer modelChow, Collins, Phys. Rev. E 52 (1994), 907 –912.

posture control – stochactically driven mechanics driven by phenomenological Langevin equation

t2y + ty = T z

2y – K y + F(z,t)

z ... height variable

y=y(t,z) ... 1D transverse coordinate

... mass density

... friction coefficient

T ... tension

K ... elastic restoring constant

F ... stochastic driving force

Page 19: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Our approach- signals = information of some dynamical system, we

do not need to know their physical meaning- we are searching for processes controlling the

dynamical system by studying the relations between different signals

- Power spectrum (related to Fourier transform)

frequency sampling ...

ation,autocorrel ...

s

kkkk

s

N

tkk

skk

f

txtxR

tf

iftR

ffP

)()()(

,2

exp)(1

)(1

Page 20: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Our approach – balance control- Correlation, Covariance

- Coherence

.)()()(

,)()()(

llkkkl

lkkl

txtxC

txtxR

.2

exp)(1

)(

,)()(

)()(

1

tf

iftR

ffP

fPfP

fPfK

N

tkl

skl

llkk

klkl

Page 21: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Measured signals

Page 22: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Power spectrum

Page 23: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

COP positions

Page 24: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Lowpass filtering

Page 25: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Lowpass filtering: Power spectrum

Page 26: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Lowpass filtering: COP positions

Page 27: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Highpass filtering

Page 28: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Highpass filtering: Power spectrum

Page 29: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Highpass filtering: COP positions

Page 30: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Heart rate

Page 31: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaging

Page 32: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Rescaling: Power Spectrum

Page 33: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged COP positions

Page 34: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged COP positions

Page 35: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Comparison of COP positions and total load force projection

Page 36: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 37: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 38: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 39: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 40: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaging without rescaling

Page 41: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaging without rescalingBlood flow in coeliac organs 400 ms after systole

Šrámek, Valenta, Klimeš: Biomechanics of the cardiovascular system.

Page 42: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 43: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 44: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force

Page 45: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Averaged load force 400-900 ms

Page 46: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Projections of av. load force 400-900 ms

Page 47: Statistical analysis of cardiac activity and processes maintaining human stability using force plate Jan Kříž Kochi University of Technology4 February.

Conclusions

- we have data from an interesting dynamical system

- we are searching for the processes controlling the system

- results (if any) can help in diagnostic medicine