Status quo IEQ in schools, health & learning performance effects Dr. Atze Boerstra REHVA vice-president & managing director BBA IEQ Consultancy email: [email protected]
Transcript
Page 1: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Status quo IEQ in schools,

health & learning

performance effects

Dr. Atze Boerstra

REHVA vice-president & managing director BBA IEQ Consultancy

email: [email protected]

Page 2: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

REHVA

REHVA is:

• Federation of European Heating, Ventilation and Air Conditioning Associations

• representing network of > 100.000 engineers from 27 countries

REHVA’s mission is:

• to develop and disseminate economical, energy efficient and healthy technology for mechanical services of building

• to serve its members and the field of building engineering (heating, ventilation and air conditioning) by facilitating knowledge exchange, supporting the development of related EU policies and their national level implementation.

For more information, see: www.rehva.eu

Page 3: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

My roots

Page 4: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Back in 1999…

‘Indoor Air Quality in

Schools is bad, we

should invest in better

ventilation systems!’‘CRAZY GUY!

NOBODY WANTS TO

INVEST IN THAT!!’

Page 5: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

What triggered our politicians…

• Hundreds of studies about Sick Building Syndrome in offices and no-one is paying attention to Indoor Air Quality at school??

• Air Quality in prisons is way better than Air Quality in prisons, can somebody explainthat??

• Voters don’t care aboutchildren, health and learningperformance??

Schools Offices Prisons

Page 6: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

NL / EU situation

Page 7: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

• Around 2005: Insufficient ventilation in > 80% of Dutch schools

• Improvement in last 10 years!

CO2-concentrations in schools

Van Dijken (TU/e), 2004BNA survey newly built schools

i.s.m. BBA Binnenmilieu, 2010

1200

ppm

Page 8: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Why is good IAQ@school so important?

Direct effect:

• discomfort (for example odor, health)

• headache, tiredness and drowsiness

• mucosa irritation (‘dry air’)

• transmission of infectious diseases

Resulting in:

• olfactory discomfort

• absenteeism students & teachers

• poorer learning performance

• hidden costs

Page 9: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Ventilation & olfactory comfort

Source: Fanger & Berg-Munch, 1983

More fresh air means

better smelling air

Page 10: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Ventilation, infectious diseases

& absenteeism

More fresh air means

less kids ill at home

Source: Milton et al., 1999

Page 11: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Some field study results

Kolarik et al., 2015:

• 635 children in 20 Danish daycare centers

• decrease of absenteeism with 12% when

ventilation rate is increased by a.e.r of 1.

Shendell et al., 2004:

• 434 classrooms in 22 American schools

• in classrooms with CO2-concentration

>1000 ppm above outside concentration

-> 10 to 20% more absenteeism of students

Page 12: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Ventilation & learning performance effects

TNO (De Gids, 2006):

• Comparison between learning performances in classroom with

sufficient ventilation (CO2-controlled) & classroom with ‘standard’

ventilation (CO2 concentration 1600 vs 800 ppm)

• Effect on learning performances strongest for MATH TESTS

• At 800 ppm 6% less mistakes on language tests and 23% less

mistakes for math testst

800 ppm 1600 ppm

More fresh air means

better learning!

Page 13: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Good news: it is improving!

New NL classrooms have substantial higher ventilation rates:

0

200

400

600

800

1000

1200

1400

Bouwvoor 2003

Renovatie na 2003

Bouw2003-2012

Bouwna 2012

Ven

tilat

ied

ebie

t per

loka

al [m

3/u

ur]

Page 14: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

India situation

Page 15: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Context quite different e.g.

Outdoor Air Quality

..

Page 16: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Fine particles (PM2.5)

1616

Source: Delhi Pollution Control Committee (four monitors); U.S. Embassy in Beijing (one monitor); Joshua S. Apte, University of Texas at Austin

Page 17: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Field study TUe / Jill Vervoort

IEQ 5 schools in Delhi (with Santrupti)

Jill Vervoort, TU/e

Page 18: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

CO2 concentrations (avg. 2 hrs)

1818

0

200

400

600

800

1000

1200

1400

1600

1800

11:02 11:16 11:31 11:45 12:00 12:14 12:28

CO

2 level [p

pm

]

Time

Classroom 1.E carbondioxide concentration

0

200

400

600

800

1000

1200

1400

1600

1800

10:04 10:33 11:02 11:31 12:00

CO

2 level [p

pm

]

Time

Classroom 5.A carbondioxide concentration

AZ7755 -indoor

AZ7755 -outdoor

Source: Eindhoven University of Technolgy, 2017

Page 19: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

PM2.5 concentrations

(indoors & outdoors)

1919

2510

0 0.2 0.4 0.6 0.8 1 1.2

0

50

100

150

200

250

300

350

07:12:00 19:12:00 07:12:00 19:12:00 07:12:00PM

2.5

level [µ

g/m

3]

Time

Classroom 1.A particulate matter

Measured indoor

Measured outdoor

WHO daily average

WHO yearly average

Source: Eindhoven University of Technolgy, 2017

Page 20: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Conclusions field study

• IAQ in Indian schools totally DIFFERENT than IAQ in European schools

• Often NO WINDOWS (just shutters, bars etc) – therefore indoor fine particle concentration = momentary outdoor concentration

• High PM 2.5 concentrations (> 10 times WHO limit) therefore serious health risk! And possibly learning performance effect too

• CO2 concentrations generally LOWER than in Europe

• Limited use of mechanical systems (apart from ceiling fans)

• Thermal comfort esp overheating risk needs attention too

• Need for improved ventilation / facade systems that keep ‘bad’ outdoor air out – huge OPPORTUNITY for HVAC sector

Page 21: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

What’s next?

• ISHRAE-REHVA cooperation

• Kickoff: this seminar

• Concept paper

• New, joint version of school guidebook

• Coordinated action to createawareness at the political, schoolboard, community side

• ….

Page 22: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

REHVA-ISHRAE concept paper

2222

Page 23: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Just a dream?

"You have to dream

before your dreams

can come true.“

Abdul Kalam

Page 24: Status quo IEQ in schools, health & learning performance ... · ventilation (CO2 concentration 1600 vs 800 ppm) • Effect on learning performances strongest for MATH TESTS • At

Let’s do this. Thank you.


Recommended