Description:
Stave Irradiation. See setup on next page Before irradiation IR imaging done with water coolant at 20.6 0 C, flow rate of 1 liter/min, 7.1 W/module First irradiation Stave in vessel with nitrogen atmosphere. Module #1(M1) end closest to source Stave in vertical position in ring source - PowerPoint PPT Presentation
Popular Tags:
15
Stave Irradiation See setup on next page Before irradiation IR imaging done with water coolant at 20.6 0 C, flow rate of 1 liter/min, 7.1 W/module First irradiation Stave in vessel with nitrogen atmosphere. Module #1(M1) end closest to source Stave in vertical position in ring source Maximum dose is 50 Mrad but varies along stave - how much is TBD. IR imaging done with water coolant at 20.8 0 C, 1 liter/min, 7.1 W/module Before and after images follow Paint quality varies(some bubbles). This affects thermography. Room temperature can vary by up to 2C, which affects measurement Error on comparison measurement around 2C(guess)
Transcript
Page 1: Stave Irradiation

Stave Irradiation• See setup on next page• Before irradiation

– IR imaging done with water coolant at 20.60C, flow rate of 1 liter/min, 7.1 W/module• First irradiation

– Stave in vessel with nitrogen atmosphere.– Module #1(M1) end closest to source– Stave in vertical position in ring source– Maximum dose is 50 Mrad but varies along stave - how much is TBD.– IR imaging done with water coolant at 20.80C, 1 liter/min, 7.1 W/module– Before and after images follow– Paint quality varies(some bubbles). This affects thermography.– Room temperature can vary by up to 2C, which affects measurement– Error on comparison measurement around 2C(guess)

Page 2: Stave Irradiation

Stave and Holder

InletOutlet

1 13

Page 3: Stave Irradiation

Module 1 - Before Module 2 - Before

Module 1 - After Module 2 - After

Page 4: Stave Irradiation

Module 3 - Before Module 4 - Before

Module 3 - After Module 4 - After

Page 5: Stave Irradiation

Module 5 - After Module 6 - After

Module 5 - Before Module 6 - Before

Page 6: Stave Irradiation

• Conclusions after first irradiation• Max temperature rise is <40C

comparing hottest points• Size of warmer regions increases

after irradiation• There is already large spread in

temperature on module before irradiation..

Module 7 - Before

Module 7 - After

Page 7: Stave Irradiation

Thermography After 2nd Irradiation• Modules 7-13 only• Operating conditions

– Water temperature 20.7C– Water flow 1.02 l/min– Power per module about 7.00.1W– Other modules are masked off except one viewed.

• In the next pages, three thermograms are shown - original(before any irradiation), after 1st irradiation, after 2nd irradiation.

• Order is shown on next page

Page 8: Stave Irradiation

Before Irradiation

After 1st irradiation After 2nd irradiation

Page 9: Stave Irradiation

Module 7

Page 10: Stave Irradiation

Module 8

Page 11: Stave Irradiation

Module 9

Page 12: Stave Irradiation

Module 10

Page 13: Stave Irradiation

Module 11

Page 14: Stave Irradiation

Module 12

Page 15: Stave Irradiation

Module 13