Date post: | 06-Apr-2018 |
Category: |
Documents |
Upload: | mesfin-derbew |
View: | 245 times |
Download: | 1 times |
of 35
8/3/2019 Steel Chap5 Ultimate Limit State
1/35
7/1/2011
1
CENG 6507-Steel Structures
CENG 6507 - Steel Structures
Course Instructor: Dr.-techn. Medhanye B.
STRUCTURAL ENGINEERING CHAIR
ETHIOPIAN INSTITUTE OF TECHNOLOGY
MEKELLE UNIVERSITY
5. Ultimate limit state of
buckling: beam-columns,
built-up members
Introduction
Limit state design requires the structure to satisfytwo principal criteria: the ultimate limit state (ULS)and the serviceability limit state (SLS).
A limit state is a set of performance criteria (e.g.
vibration levels, deflection, strength, stability,buckling, twisting, collapse) that must be met whenthe structure is subject to loads.
All engineering design criteria have a common goal:that of ensuring a safe structure and ensuring thefunctionality of the structure.
8/3/2019 Steel Chap5 Ultimate Limit State
2/35
7/1/2011
2
Ultimate Limit State
To satisfy the ultimate limit state, the structuremust not collapse when subjected to the peakdesign load for which it was designed.
A structure is deemed to satisfy the ultimate limitstate criteria if all factored bending, shear andtensile or compressive stresses are below thefactored resistance calculated for the sectionunder consideration.
Whereas Magnification Factor is used for theloads, and Reduction Factor for the resistance ofmembers.
Serviceability Limit State
To satisfy the serviceability limit state criteria, astructure must remain functional for its intendeduse subject to routine (everyday) loading, and assuch the structure must not cause occupantdiscomfort under routine conditions.
Examples: Deflection, Vibration, Crack widths inconcrete
8/3/2019 Steel Chap5 Ultimate Limit State
3/35
7/1/2011
3
ULS: TYPES OF STEEL FAILURE
Failure can happen because ofa) yielding of members
b) failure of connections- most common cause of steel buildingscollapse
c) buckling of members
- buckling of columns rarely has resultedin structural failure
Tension members are linear members inwhich axial forces act so as to elongate
(stretch) the member.
Tension members carry loads mostefficiently, since the entire cross section issubjected to uniform stress.
Unlike compression members, they do notfail by buckling
Tension MembersDesign consideration of tension members
Tension members are efficient structural elements but its
efficiency may be affected by:- End connection (e.g. Bolt holes reduce member section)
Reversal of load (buckling)
Bending moments
Design of Axially loaded Tension members (EBCS-3, 1995)
The design value of the axial tension force isWhere Nt,Rd is the design tension resistance capacity
of the x-section taken as the smaller of:
1. The design plastic resistance of the gross section is
2. The design ultimate resistance of the net section
at the bolt hole is
RdRdRdRdt,t,t,t,SdSdSdSdt,t,t,t,NNNNNNNN
1
,
M
y
Rdpl
AfN
=
2
,
9.0
M
ueff
Rdu
fAN
=
8/3/2019 Steel Chap5 Ultimate Limit State
4/35
7/1/2011
4
BUCKLING OF STEEL MEMBERS
Buckling of steel may happen in
a) members under compression
b) members under bending
c) members under combined loading:compression + bending
Local Buckling and Section Classification
Internal or outstand elementsinternal
are the webs of open beams or the flanges of boxes
outstand
are the flanges of open sections and the legs of angles
Outstand
Internal
Web
Flange
Web
Internal
Flange
(a) Rolled I-section (b) Hollow section
Flange
(c) Welded box section
InternalOutstand
InternalWeb
Local buckling
As the plate elements in structuralsections are relatively thin compared withtheir width, when loaded in compression
they may buckle locally
Local buckling within the cross-sectionmay limit the load carrying capacity of thesection by preventing the attainment ofyield strength.
8/3/2019 Steel Chap5 Ultimate Limit State
5/35
7/1/2011
5
Classes of cross-sections
Premature failure (arising from the effects oflocal buckling) may be avoided by limiting thewidth to thickness ratio - or slenderness- ofindividual elements within the cross section.
This is the basis of the section classificationapproach.
EBCS-3, 1995 defines four classes of cross-
sections. The class into which a particular cross-section
falls depends upon the slenderness of eachelement and the compressive stress distribution.
Four classes of cross-section are:-1. Class 1 or plastic cross-sections:-
Design of Steel Structures for plastic elements.
A plastic hinge can be developed with sufficient rotationcapacity to allow redistribution of moments within the structure.Only Class 1 section may be used for plastic design.
2. Class 2 or compact cross-sections:
The full plastic moments capacity can be developed but local
buckling may prevent development of a plastic hinge withsufficient rotation capacity to permit plastic design. Class 2sections can be used without restriction except for plasticdesign.
3. Class 3 or semi-compact sections:-
The stress at the extreme fibers can reach the design strengthbut local buckling may prevent the development of the fullplastic moment. Class 3 sections are subjected to limitationson their capacity.
4. Class 4 or thin-walled sections:-
Local buckling may prevent the stress in a thin-walled sectionfrom reaching the design strength. Design of Class 4 sectionsrequires special attention.
8/3/2019 Steel Chap5 Ultimate Limit State
6/35
7/1/2011
6
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
7/35
7/1/2011
7
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
8/35
7/1/2011
8
(b) Class 4 cross-sections - bending moment
(a) Class 4 cross-sections - axial force
Gross cross-section
Gross cross-section
Centroidal axis ofgross cross-section
Centroidal axis of
gross cross-section
Centroidal axis ofeffective cross-section
Non-effective zones
Non-effective zone
Non-effective zone
Centroidal axis
Centroidal axisCentroidal axis ofeffective section
e N
eM
e M
Centroidal axis ofeffective section
Effective cross-
sections for class4 in compressionand bending(class 4 x-section )
Stress distribution(compression positive)
Effective width beff
c
beff
1
2
1 0> :
beff= c
1
2
bt bc
beff
< 0 :
b b ceff c= = / ( )1
=2 1/
Buckling factor k
1
0,43
0
0,57
-1
0,85
1 1
0 5 7 0 2 1 0 07 2, , , +
c
beff
1
2
1 0> :
beff= c
beff
1
2
btbc
< 0 :
b b ceff c= = / ( )1
=2 1/
Buckling factor k
1
0,43
1 0> >
0578
0 34
,
, +
0
1,70
0 1> >
1 7 5 17 1 2, , +
-1
23,8
Effective widths ofoutstandcompressionelements
(EBCS-3, Tab. 4.4)
Stress distribution
(compression positive)Effective width b eff
be1 be2
1
2
b
= 1:
b = b - 3t
beff=b
be1 = 0,5 beff
be2 = 0,5 beff
be1 be2
1
2
b
1 0> > :
b = b - 3t
beff=b
be1 =2
5
beff
-
be2 = beff- be1
be1 be2
1
2
b
bc bt < 0:
b = b - 3t
b b beff c= = - / ( )1
be1 = 0,4b eff
be2 = 0,6b eff
=2 1/
Buckling
factor k
1
4,0
1 0> >
8 2
1 05
,
, +
0
7,81
0 1> > -
7 81 6 92 9 78 2, , ,- +
-1
23,9
- > > -1 2
598 1 2, ( )-
Alternatively, for 1 1-> > : k =
+ + - + +
16
1 0112 1 12 2 0 5[( ) , ( ) ] ( ),
Illustrated as rhs.
For other sections b = d for webs
b= b for internal flange elements (except rhs)
_
_ _
Effective widths of
internalcompressionelements
(EBCS-3, Tab. 4.3)
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
9/35
7/1/2011
9
Compression Members The strength of steel compression members is
usually limited by their tendency to buckle. If a 6mm diameter steel rod 1m long is placed in
a testing machine subjected to a pull, it will befound to carry a load of about 7KNbefore failureoccurs. If on the other hand this same rod hadbeen subjected to compression, then themaximum load, which would have been carried,would be about 0.035KN, a very big difference
Failure in the first test occurs by the fracture ofthe member, in the second it is due to bendingout of the line of action of the load.
The load at which a compression memberbecomes unstable is the buckling load.
The buckling load depends on the length, cross-section, and end conditions of the column andthe stiffness of the material.
Buckling Load
Pcr is the load at which the compressionmember becomes unstable
E is modulus of elasticity of steel
I is moment of inertia of the cross section
L is the length of the compression member
K is the effective length factor
2
2
2
2
)(KL
EI
L
EIP
e
cr
==
EFFECTIVE LENGTH OF COLUMNS
The effective length, Le, of a
member hinged at its ends is thedistance between the axes of thehinges.
K, is the ratio of the length (Le) ofthe equivalent column to the actuallength (L); and the length of theequivalent column is the distancebetween two consecutive points ofcontraflexure (points of zeromoment) in the actual column.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
10/35
7/1/2011
10
Effective Length FactorsBuckling of a column in a non sway frame
Buckling of a column in a sway frame COLUMNS OF NON-SWAY FRAMES
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
11/35
7/1/2011
11
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
12/35
7/1/2011
12
Design steps for Axially Compressed Members1. Determine the axial load, Nsd.2. Determine the buckling length,
3. Select a trial section (take into consideration economy, i.e.least weight per unit length).4. Determine the Class of the section according to Section
4.3.2 and Table 4.1. If the cross-section is classified asClass 4, determine Aeff according to Section 4.3.4 andTable 4.4 (Sec 4.5.4.3)
5. Determine the non-dimensional slenderness ratio(Section 4.5.4.3)
6. Determine the appropriate buckling curve, Table 4.11
7. Determine the value of . Interpolation must be used to
determine more exact values, Table.4.98. Calculate the design buckling resistance Nb,Rd of themember. Buckling about both principal axes must bechecked.
9. Check the computed buckling resistance against theapplied load. If the calculated value is inadequate or is toohigh, select another section and go back to Step 4.
y
zP
z
x
P
x
y
Example-1:The column B E on the Figure shown below is under theaction of NSd = 2800 kN. Both sides are pinned. Check theresistance of the column. Steel grade Fe 430 is used.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
13/35
13
Solution:
Step 1: Axial load NSd = 2800 kN.
Step 2:Buckling length L = 4000 mm (pinned endboth sides. Frame non-sway mode).
Step 3: The section is given.
Step 4:Determine the class of the cross-sectionand check for a local buckling. The sectionis subjected to uniform compression.
For the section to be classified as at least class 3, in order
to avoid any modification to the full cross sectional areadue to local buckling, the limiting width to thickness ratio for
class 3 section are (See Table 4.1 EBCS-3).
Outstand element of compression flange: c/tf 15 .
Web subject to compression only: d / tw 42 .
For Fe 430 steel grade fy = 275 N / mm2.Thus
This gives the following limiting values:
Outstand element of compression flange:
c / tf = (254/2) / 16.3 = 7.78 < 15 x 0.92 = 13.8 OK.
Web subject to compression only:
d/tw = (310-2(33))/9.1 = 26.8 < 42 x 0.92 = 38.64 OK.
Therefore, the section belongs to at least Class 3.Thus, A = 1.0
92.0275
235 ==
Step-5: Determine the non-dimensionalslenderness ratio.
For Fe 430 steel grade,
1 = 93.9 = 93.9 x 0.92 = 86.39
Slenderness ratio about y-axis:
y = L / iy = 4000/135 = 29.63
Slenderness ratio about z-axis:
z = L / iz = 4000/63.6 = 62.89
Hence, the non-dimensional slenderness ratio isdetermined as:
( )
( ) 73.0139.86
89.62
34.0139.86
63.29
1
1
==
=
==
=
Az
z
Ay
y
Step-6: Determine the appropriate column curves(Table 4.11 EBCS-3).
Use curve a for buckling about y-axis and curve bfor buckling about z-axis.
Step 7: Determine value of . Using Table 4.9 andinterpolating:
For y-axis: curve a for
For z-axis: curve b for
Therefore, buckling about the z-axis becomes critical.
403.1622.1254
310
8/3/2019 Steel Chap5 Ultimate Limit State
14/35
14
Step-8: Calculate the design buckling resistance.
Step 9: Because 2800 kN > 2117.5 kN, the column
do not resist.
N.B. Please note that even the plastic capacity ofthe section (2750 kN) is less than the applied load(2800 kN)
kNNxxxAf
NM
yA
Rdb 5.211721175001.1
27511000177.0
1
, ====
(Only to show the method!!) Add an additionalhinged support at mid-height to increase the
resistance about the minor axis.Go to Step 5.
Slenderness ratio about y-axis = 29.63 (doesnt vary)
Slenderness ratio about z-axis = 2000/63.6 = 31.45
Non dimensional slenderness ratio
(doesnt vary)
Values of :
y-axis: y = 0.97 doesnt vary
z-axis: Curve b for
Hence buckling about the z-axis becomes critical
34.0=y
( ) 36.01
39.86
45.31==z
94.036.0 == zz
resisttdoesnkNkNxx
N Rdb '.280025851.1
2751100094.0,
==
Example-2:Determine the design buckling resistance ofa 457 x 152 x 52 UB used as a pin-ended
column. The column is 3m long and its steelgrade is Fe 360.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
15/35
15
Solution:Step 1: buckling strength is required!
Step 2: Buckling length = 3000 mm.Step 3: The section is given.
Step 4: Determine the class of the cross-sectionand check for local buckling.
For Fe-360 steel grade fy = 235 N / mm2.
Thus,
These the limiting values for an I-section are:
Outstand element of compression flange: c/tf15=15
Web subject to compression only: d / tw 42 = 42
1235 ==yf
For the 457x152x52UB profile, the actual values are:
Outstand element of compression flange:
c / tf = (152.4 / 2) / 10.9 = 7 < 15 OK.Web subject to compression only:
d / tw =(449.8 2x10.9 2x10.2) / 7.6 = 53.60 > 42
Therefore, the flange satisfies the Class 3requirement, but the web is Class 4 section.Consequently, there must be a reduction in the
strength of the section to allow for the local bucklingwhich will take place in the web. Therefore, theeffective area, Aeffmust be determined for the web!
The effective width is beff = reduction factor x b = x b.
The method to calculate the effective area (Aeff) isexplained in section 4.3.4 of EBCS-3.
The reduction factor is given by,
a) = 1; if
b)
Where
In which: t is the relevant thickness.
k
is the buckling factor corresponding tothe stress ratio from Table 4.3 or 4.4as appropriate.
for webs.
673.0p
( )673.0
22.02 >
= p
p
p if
( ) kt
bp 4.28
=
db =
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
16/35
16
In this example, since the column is axially loadedthe stress distribution is uniform, i.e. 1 = 2.
Table 4.3 is used to calculate the effective width.Thus, 1/2 = 1 & k = 4.0 (see lower part of Table 4.3)
6.536.7
6.407
6.407
==
==
wtb
mmdb
( )( ) ( )
mmxbbAnd
xx
eff
p
p
p
2.3316.407812.0
812.0944.0
22.0944.022.0
673.0944.0
414.28
6.53
22
===
=
=
=
>==
Therefore the area that should be ignored at thecenter of the web is:
And then
Step 5: Determine the non-dimensional slendernessratio (axis-z govern).
Hence the non dimensional slenderness ratiobecomes
( )2
4.5816.72.3317.407 mmxA ==
( )913.0
66504.5816650
=
==A
AeffA
9.939.93
5.961.31
3000
1 ==
==
z
( )98.0913.0
9.935.96
1
==
= Azz
Step 6: Appropriate column curve:
For h/b = 449.8/152.4 = 2.95 > 1.2; & tf = 10.9 < 40 mm;
use curve b for buckling about z-axis.
Step 7: Determine the value of .
Using Table 4.9 and interpolating, z-axis: curve b for
Step 8: Design buckling resistance:
Answer:The design buckling resistance will then be
6034.098.0 == zz
NxxxAf
NM
yA
Rdb 7826601.1
2356650913.06034.0
1
, ===
.66.782, kNN Rdb =
Strength of flexural members are limited by: Local buckling of a cross section
Lateraltorsional buckling of the entire member
Development of a plastic hinge at a particularcross section
General Stability (Lateral torsional buckling)Stability Due to shear on the web.
Local Stability
Due to compressive stress onthe flange
Beams can be
Laterally restrained (supported)
Laterally non-restrained (unsupported)
Bending/Flexural Members
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
17/35
17
Restrained Beams: Beams which are unable to move laterally are
termed restrained. and are unaffected by out-of-plane buckling (lateral-torsional instability).
Beams may often be designed on basis ofbending moment resistance.
Moment resistance is dependent on sectionclassification.
Co-existent shear forces, affect momentresistance.
Restrained &unrestrained Beams Restrained Beams (Contd)
Beams may be considered restrained if
Full lateral restraint is provided by for example positiveattachment of a floor system to the top flange of a simplysupported beam
Adequate torsional restraint of the compression flange isprovided
Closely spaced bracing elements are provided such thatthe minor axis slenderness is low
Moment resistance
In a simple single span beam, failure occurs when thedesign value of the bending moment (Msd) exceeds thedesign moment resistance of the cross-section (MC,Rd) ,
The magnitude of which depends on the section shape,material strength and section classification
Resistance to bending moment
According to EBCS-3, for bending about oneaxis in the absence of shearing force, the designvalue of bending moment .
Resistance to shear
The design value of the shear force VSd at eachcross-section shall satisfy
RdcSd MM ,
RdplSd VV ,
Restrained Beams
The design moment resistance (Mc,Rd) may be taken as:For class 1 & 2 cross-sections, the design plasticresistance moment of the gross section
Mc.Rd= Mpl.Rd=
For a class 3 cross-section, the design elastic resistancemoment of the gross section
Mc.Rd= Mel.Rd=
For a class 4 cross-section, the design local bucklingresistance
Mc.Rd= Mo.Rd=Shear resistance
the plastic shear resistance, Vpl.Rd of a shear area (Av)
W fpl y
M
.
0
0
.
M
yelfW
1
.
M
yefffW
MO
y
vRdpl
fAV
)3/(. =
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
18/35
18
Resistance for bending and shear
The theoretical plastic resistance moment of a cross-section is reduced by the presence of the shear.
For small values of the shear force this reduction is notsignificant and may be neglected. However, when theshear force exceeds half of the plastic shear resistance,
allowance shall be made for its effect on plasticresistance moment.
That is, if the value of the shear force VSd does notexceed 50% of the design plastic shear resistance noreduction need be made in the resistance moments
When VSd exceeds 50% of Vpl the design resistancemoment of the cross-section should be reduced to Mv,Rdobtained as stated in EBCS Article 4.6.1.3 (3).
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
19/35
19
Local Stability
During bending, part of the web and at least one flange isunder compressive stress, therefore can be subjected to loss
of stability.
1) Shear buckling resistance: Near the support, where thereis a considerable acting shear force, the web of the beamcan lose its stability through the formation of web folds of
buckles.
This problem is prevented by providing transverse
stiffeners as shown in the figure below.
2. Flange induced buckling
As we can see in the figure below, the upperflange is under the action of the compressive
stress and may lose it local stability
Laterally Unrestrained Beams
Beams bent about the major axis may fail by buckling in amore flexible plane
This form of buckling involves both lateral deflection andtwisting - Lateral-torsional buckling
When the beam has a higher bending stiffness in the verticalplane compared with the horizontal plane, the beam can twistsideways under the action of the load as shown in the Figure
below. The applied moment at which a beam buckles by deflectinglaterally and twisting reached is the elastic criticalmoment
Dead weight
load applied
vertically
Buckled
position
Unloaded
position
Clamp at
root
slender cantilever beamloaded by a vertical end load.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
20/35
20
A reduction factorfor lateral torsional buckling, LT
is
used to determine the capacity
The design buckling resistance moment(Mb.Rd) of alaterally unrestrained beam is thus taken as:
5,0
2
2
2
2
+=
z
t
z
wzcr
EI
GIL
I
I
L
EIM
( )
( ) ( )
+
+
= g2
5.0
2g2
z2
t2
z
w
2
w2
z2
1cr zCzCEI
GIkL
I
I
k
k
kL
EICM
1,, / MyyplwLTRdb fWM =
The elastic critical moment(Mcr) for LTB is
EBCS-3,Section 4.6.3P(78-84)
The values of the imperfection factor LT for lateraltorsional buckling should be taken as:LT = 0,21 for rolled sectionsLT = 0,49 for welded sections
Refer to the same table like those of membersunder compression and with: for rolled sections:
curve a ( = 0,21) for welded sections:
curve c ( = 0,49)
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
21/35
21
The resistance of an unstiffened web to transverse forcesapplied through a flange, is governed by one of the followingmodes of failure:
1. Crushing of the web close to the flange, accompanied by plasticdeformation of the flange. See (a).
2. Crippling of the webin the form of localized buckling and crushingof the web close to the flange, accompanied by deformation of the
flange. See (b).3. Buckling of the webover most of the member. See (c).
Resistance of web to transverse forces
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
22/35
22
Example:Bending members
A simply supported beam 7.0 m span is laterallysupported at the third points and carriesunfactored uniform loads of 18.5 kN/m imposed
load and 9.4 kN/m permanent load. In addition, thebeam carries unfactored concentrated loads of 50kN permanent load and 50 kN imposed load at midspan . Find a universal beam of grade Fe 430.
Solution:Geometry, materials and loads
Factored loads:
Imposed loads: q = 1.6 x 18.50 = 29.60 kN/m
Q = 1.6 x 50.00 = 80.00 kN.
Permanent loads: g = 1.3 x 9.40 = 12.20 kN/m
G = 1.3 x 50.00 = 65.00 kN.
Fe 430; fy = 275 N/mm2
(assume t 40 mm)
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
23/35
23
Step 1: Maximum bending moment and shear
force:
Step 2: Required plastic modulus:
Try 533 x 210 x 92 UB.
( ) ( )
( ) ( )kN
xV
mkNxx
M
8.2182
6580
2
72.126.29max
8.5094
76580
8
72.126.29max
2
=+
++
=
=+
++
=
3
2
2
1
20391.1)/(5.27
)(108.509cm
cmkN
cmkNx
f
MW
My
el =
==
Step 3: Selection of the profile:
The relevant section properties are:
Class of section
The section is at least Class 2.
The relevant section properties are:
h = 533.1 mm w = 0.92 kN/m It = 76.2 cm4
d = 476.5 mm A = 118 cm2 Iw = 1.6 x 106 cm6
tf= 15.6 mm Iy = 55400 cm4
tw = 10.2 mm Iz = 2390 cm4
b = 209.3 mm Wel,y = 2080 cm3
Wpl,y = 2370 cm3
92.0275
235==
OKx
OKx
92.0837.462.10
5.476
92.01170.66.15
23.209
8/3/2019 Steel Chap5 Ultimate Limit State
24/35
24
Step 7: Check for lateral torsional buckling.
The section is Class 1 and
Determination of Mcr.
Lateral support to the beam is provided at the ends at thethird points. Therefore the effective buckling length is:
L = span/3 = 7000/3 = 2333 mm.
The critical moment for lateral-torsional buckling is:
Take C1 = 1.132; G = 80 Gpa
and
2.992.01070.66.15
3.209.1
,
, ====== LTandx
9250.0=LT
mkNmkNxxxxx
M Rdb >== 51754810
1.1
27510237019250.0 63
,
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
25/35
25
Beam-columns are defined as members subject tocombined bending and compression. In principle,all members in frame structures are actually beam-columns
Beam-Column members
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
26/35
26
Buckling Resistance of compressionmembers with moments.
The total stress due by the combined action of axial forceand bending moment is:
, then we can write
and finally:
Now, taking into account the problem of the loss of stability,
the design according with EBCS-3 is as follows:
1
,,
M
y
zMyMN
f
++
111
,
1
++My
Mz
My
yM
My
N
fff
1111
+
+ Myz
z
Myy
y
My fWM
fWM
fAN
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
27/35
27
Example:A 4.00 m pin-ended column supports a beamwith a reaction of 100 kN permanent load and 150 imposedload. Assuming the beam reaction to be applied 75 mmfrom the face of the flange. Check the adequacy of a 203 x203 x 46 UC grade 430 steel profile.
Table 4.1
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
28/35
28
Sec 4.5.4.3
Table 4.11 Tab.4.9
BM-Coln
Fig 4.13
BenMem
bding
Table4.12
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
29/35
29
Built-up compressionmembers
Build-up members, made
out by coupling two or moresimple profiles for obtainingstronger and stiffer sectionare very common in steelstructures, usually forrealizing members whichare usually undercompression.
Two of the most commonarrangements for built-upmembers are representedin the figure to the right.
Although the discrete nature of the connections betweenthe two members connected by lacings and/or battenings,the models that will be described in the following foranalyzing and checking built-up members are based on theassumption that the member is regular and smearedmechanical properties (such as, flexural stiffness) can be
assumed throughout the member axis and utilized incalculations.
Consequently, some regularity requirements are usuallyimposed in designing these members and can be listedbelow as a matter of principles:
- the lacings or battenings consist of equal modules with parallelchords;
- the minimum numbers of modules in a member is three.
The key models which can be utilized for the stability
check of this kind of members will be discussed in thissection.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
30/35
30
Shear Flexibility of members and critical load:
While shear flexibility can usually be neglected in memberswith solid sections, built-up members are hugely affectedby these parameters as a result of the axial deformation oflacings and out-of-plane flexural flexibility of the chordmembers.
Consequently, the critical load of built-up members have tobe evaluated taking into account the role of shear stiffnessSv. By definition, the shear stiffness, Sv, is the force
resulting in a unit value of the shear deformation .
Since imperfections play an even important role in bothstrength and stability checks of built-up members, aconventional eccentricity e0 is usually introduced forsimulating their effect in amplifying the axial action N
Sd. For
instance, EBCS-3, 1995 provides the following value ofeccentricity as a function of the member span length L:
Nevertheless, it is worth emphasizing the role of shearflexibility on the value of eccentricity to be adopted inverifications; indeed, since second order effects are usuallyof concern, the following magnified value of eccentricity hasto be considered to take into account its total value:
The expression of the magnification factor considered inthe above equation is based on consideration of the role ofshear flexibility.
As a matter of principle, the above eccentricity of the axialforce results in an external moment M which can bedefined as follows:
Then the compression in one of the two connected
members can be estimated as follows:
where h0 is the distance between the centroids of the two
chord members.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
31/35
31
Laced compression members:
Laced members are made out of two chords connected bya bracing system with inclined lacings, in which each
segment of longitudinal profile between two braced nodescan be regarded as an isolated beam-column, whoselateral slenderness is considerably reduced at leastthroughout the plane of lacings.
The stability check, along with all the structural verificationdealing with members and connections, have to be carriedout by assuming an accidental eccentricity due to
imperfections. Consequently the design action in the singlechord of a laced member with total axial force is NSd can be
derived according to the following equation:
The value of the critical load Ncr has to be determined byneglecting the shear flexibility influence. Consequently, theusual expression can be considered:
where the effective moment of inertia Ieff is defined for oneof the two axes which does not cross all the connectedchord sections:
Af being the area of the single chord section and h0 the distance
between their centroids.
A virtual shear force VS, for the strength check of the
connections can be determined as a function of the aboveeccentricity e
0
:
Moreover, the diagonal members have to be checkedconsidering the following value for axial force Nd:
v
sd
cr
sd
sdss
S
N
N
N
eN
LL
MV
=
=
10
Laced
compression
member
Example:
Let us consider the laced member shown below stressed incompression under an axial force whose design value isNSd=3500 kN. The member is 10 m high and simply hingedat its ends. Chord members
are IPE 450 profiles while
diagonals consists of
steel plates with 60x12 mm2
rectangular section both made
out of grade Fe-360 steel.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
32/35
32
Cross-Sectional Properties:
Solution:
Stability check according to EBCS-3 provisions:
Step #1: classifying the transverse section:Since the thicknesses of the elements are less than 40mm, theyield strength of the steel used is fy=235 Mpa and the value =1.
The following values of the length-to-thickness ratios can beevaluated for flange and web:
Finally, the profile IPE 450 made out of steel FE-360 is in class3 if loaded in compression.
Step #2: evaluating the design actions:
The eccentricity e0 which has to be considered for taking intoaccount the possible imperfection effects is:
The effective value of the moment of inertia of the built-up
section Ieff can be also calculated as:
The shear stiffness for the current configuration will be given by
The elastic critical load Ncr can be then easily evaluated as:
in which the overall effective length L=10000 mm has been
considered since the calculation is aimed at deriving the totaleffect of the eccentricity e0 on the beam-column as a whole.Indeed, the moment MS induced by the eccentricity e0 can beevaluated as follows:
taking into account the magnification effect due to second orderdisplacements.
Finally, the actions on the various members can be easilyderived as follows:
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
33/35
33
Step #3: performing the stability check of the chord members:
The reduction factor due to the slenderness
of the member has to be calculated by looking
after the possible instability in both the principal
direction y and z.
Step #3.1: calculation of y for instability in the z direction:
As far as the possible instability in the plane orthogonal to the y-axis (namely, buckling in z direction) is considered, the value ofthe effective length coincides with the overall span length of themember, since no lacings restraints buckling in the considereddirection, lying the diagonal members in a plane parallel to they-axis. Consequently Lo,y=10000 mm and the moment of inertiaof the single longitudinal chord member is Iy:
The non-dimensional slenderness can be derived as a functionof the elastic critical load Ncr,y as follows:
The profile follows the curve a and, consequently, the followingvalue of the reduction factor y can be evaluated:
Step #3.2: calculation of z for instability in the y direction:
On the contrary, as far as the possible instability in the plane
orthogonal to the z-axis (namely, buckling in y direction) isconsidered, the value of the effective length coincides with thediagonal spacing, since buckling in y direction is forced bylacings to develop only between two adjacent nodes.
Consequently L0,z=1000 mm and the moment of inertia of the
single longitudinal chord member is Iz, have to be determinedaccording to:
The non-dimensional slenderness can be derived as a function
of the elastic critical load Ncr,z as follows:
The profile follows the curve b and, consequently, the followingvalue of the reduction factor y can be evaluated as:
Step #3.3: calculating the axial bearing capacity :
Since y
8/3/2019 Steel Chap5 Ultimate Limit State
34/35
34
Battened members:
Battened members are widely utilized as a technologicalsolution for realizing beam-columns in industrial buildings.
Due to the significant flexural stiffness of battenings and therelated connections with the chord members, the nodes
between the longitudinal profiles and the horizontal battenings isusually assumed as completely fixed, rather than hinges asusually considered for laced members.
Consequently, the lateral shear flexibility of this kind of members
can be determined considering the following three contributions:- bending in longitudinal members;
- bending in battening;
- shear strains in battenings.
Since battenings are usually assumed infinitely stiff with respectto the chord sections, EBCS-3 provided a lower bound for theirmoment of inertia Ib with respect to one of the chord member
and other geometrical parameters:
..abeing the battening spacing.
The compressive force Nf,Sd
acting on the single chord membercan be determined as follows for taking into account the effectof eccentricity e0 due to imperfections:
where the moment Ms is defined as follows:
and the effective moment of inertia can be estimated as follows:
The parameter is basically defined as a function ofslenderness :
where the mentioned slenderness is defined as:
and
with I1 equal to Ieff assuming =1
The elastic critical load Ncr can be evaluated according to the
following expression:
In the general case, the shear stiffness Sv has to be evaluatedas follows:
The shear force to be considered in local verifications according
to the equilibrium conditions can be evaluated as alreadydescribed for laced members.
7/1/2011
8/3/2019 Steel Chap5 Ultimate Limit State
35/35
35
Finally, EBCS-3 classifies the battened members on the basis ofthe distance between the longitudinal chord members. Inparticular, for closely spaced members, the above provision
does not apply and the general procedure given for the usualmembers described in the previous chapters can be applied.
Examples of closely spaced battened members are representedin the figure below and considering different types oflongitudinal profiles.
CHAPTER
END!