www.leufen-medical.de creating stability
stents Made in Germany
aixstent ® oesophagus 4oesophagus leakage 5 oesophagus ues 6oesophagus cardia umbrella 7duodenum colon 8biliary duct 9biliary duct laser cut 10 biliary duct percutaneous 11 biliary duct hilus 12 pancreatic 13 pseudocyst 14 colon rectum 15colon rectum anastomosis 16 guide wire 0.021 inch 17 aerstent ® trachea bronchus 18 y carina 19 j carina 20 guide wire 0.035 inch 21 precision up to the finest detail 22
Made in Germany
With our product lines aixstent® and aerstent® you can expect a high quality product made in Germany which meets all of your ambitious requirements fully.There are three sectors in which Leufen Medical is acting as a role model and stent pioneer
• innovative development• precise manufacture• patient specific product distribution
We go the extra mile for you
Ideas that inspire. Quality that convinces. Advice that leaves no question unanswered. Leufen Medical, the Aachen-based medical technology company, has been supplying self-expanding stents for gastroenterology and pneumology since 2003. Our high standards of quality and functionality have not just earned us the trust of doctors and patients, but have also made us the market leader in pneumological stents. Our stents are valued by doctors in Germany and beyond. Due to high international demand, we have established a branch in France and work with certified trading companies throughout Europe. For us, expansion means being on-site. Personal, professional. But expansion also means driving innovation, developing new ideas and bringing visions to life. At conferences, we present the latest developments in the field of medical technology and in clinical practice, in collaboration with our partners. We place particular emphasis on the therapeutic use of stents. So even today we are helping shape the future.
Sincerely yoursChristoph Leufen
creating stability 4
aixstent®
www.leufen-medical.de
Leufen Medical offers a huge variety of self-expandable oesophageal stents with diameters of 20 and 24 mm and lengths from 60 to 140 mm. The special end design and the strong radial force keep the stents in position and avoid stent migration. All oesophageal stents are pre-mounted on the reloadable delivery system. For correction of the stent position, the stent can be charged into the delivery system during the procedure. The excellent radiopacity of the tantalum markers makes the stents clearly visible in fluoroscopy.
• Stent with partial or complete silicone cover• Atraumatic ends• High tensile, dark colored extraction threads on both ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Reloadable delivery system
Length 700 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aixstent · oesophagus · partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends102-20-060 60 30 20 26102-20-080 80 50 20 26102-20-100 100 70 20 26102-20-120 120 90 20 26102-20-140 140 110 20 26102-24-080 80 50 24 30102-24-100 100 70 24 30102-24-120 120 90 24 30102-24-140 140 110 24 30
aixstent · oesophagus · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends103-20-080 80 80 20 26103-20-100 100 100 20 26103-20-120 120 120 20 26103-20-140 140 140 20 26103-24-080 80 80 24 30103-24-100 100 100 24 30103-24-120 120 120 24 30103-24-140 140 140 24 30
oesophagus
5
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
To cover tracheo- or broncho-oesophageal fistulas or in case of spon-taneous or iatrogenic ruptures (such as Boerhaave syndrome), Leufen Medical offers a 80, 100 and 120 mm stent with a diameter of 28 mm. The special design of the stent ends and the stable expansion force hold the stent in its foreseen position, thus preventing stent migration. The oesophagus leakage stent is pre-mounted on the new reloadable delivery system. For a precise positioning, the stent can be retracted into the delivery system during the procedure. The excellent radiopacity of the tantalum markers makes the stents clearly visible in fluoroscopy.
• Stent with complete silicone cover• Atraumatic ends• High tensile, dark colored extraction threads on both ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Reloadable delivery system
Length 700 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aixstent · oesophagus leakage · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends103-28-080 80 80 28 34103-28-100 100 100 28 34103-28-120 120 120 28 34
oesophagus leakage
creating stability 6
aixstent®
www.leufen-medical.de
oesophagus ues
High-seated oesophageal strictures near the transition to the pharynx require precise stent placement. The proximal to distal release and the design of the stent-ends offer the best adaption to this demand.
The upper oesophagus stent is preloaded on the delivery system for proximal release. For exact positioning, the stent is released with a thread system from proximal to distal after retracting the outer sheath. The excellent radiopacity of the tantalum markers makes the stents clearly visible in fluoroscopy.
• Stent with complete polyurethane (PU) cover• Atraumatic ends• High tensile, dark colored extraction threads on both ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Delivery system with proximal release
Length 700 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aixstent · oesophagus ues · complete PU cover
REF Total Length Length Cover Ø Middle Ø Ends133-20-080 80 80 20 26133-20-100 100 100 20 26133-20-120 120 120 20 26133-24-080 80 80 24 30133-24-100 100 100 24 30133-24-120 120 120 24 30
7
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
aixstent · cardia umbrella · partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends122-24-100 100 85 24 30 / 50122-24-120 120 105 24 30 / 50
aixstent · cardia umbrella · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends123-24-100 100 100 24 30 / 50123-24-120 120 120 24 30 / 50
Oesophageal strictures close to the cardia require a specific stent design. The cardia umbrella stents have an umbrella designed distal end which significantly reduces irritations at the greater curvature of the stomach and prevent an in- or overgrow of tumor into the stent. All cardia umbrella stents are pre-mounted on the reloadable delivery system. For correction of the stent position the stent can be reloaded into the delivery system during the procedure. The excellent radiopacity of the tantalum markers makes the stents clearly visible in fluoroscopy.
• Proximal partial or complete silicone cover• Atraumatic ends• Distal end umbrella design• High tensile extraction thread on proximal end• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Reloadable delivery system
Length 700 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
cardia umbrella
creating stability 8
aixstent®
www.leufen-medical.de
The self-expandable Nitinol stents to bridge strictures in the duodenum and colon are preloaded on the new braided TTS (through-the-scope) delivery system. The guidance stability of this delivery system guarantees a precise and reliable stent placement under endoscopic view and under x-ray control. The high flexibility of the stent follows perfectly the anato-mic specification in the duodenum and colon which reduces the risk of migration.
• Duodenum stent without and with partial silicone cover• Colon stent without cover• Atraumatic ends• Special tulip design prevents migration • Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Delivery system
Length 2300 mm, TTS Ø 3.3 mm / 10 French Accepts guide wire 0.035 inch
aixstent · duodenum · no cover and partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends201-20-060 60 without 20 26201-20-080 80 without 20 26201-20-100 100 without 20 26202-20-060 60 40 20 26202-20-080 80 60 20 26
aixstent · colon · no cover
REF Total Length Length Cover Ø Middle Ø Ends411-25-080 80 without 25 30411-25-100 100 without 25 30
duodenum colonintestinal – TTS
9
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
aixstent · biliary duct · no cover
REF Total Length Length Cover Ø Middle Ø Ends301-10-040 40 without 10 10301-10-060 60 without 10 10301-10-080 80 without 10 10
aixstent · biliary duct · partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends302-10-040 40 30 10 10302-10-060 60 50 10 10302-10-080 80 70 10 10
aixstent · biliary duct · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends303-10-040 40 40 10 10303-10-060 60 60 10 10303-10-080 80 80 10 10
The self-expandable Nitinol stents are used to bridge benign and malig-nant strictures in the biliary ducts. The high guiding stability of the new braided TTS (through-the-scope) delivery system guarantees a precise and reliable stent placement under endoscopic view and under x-ray control. The biliary duct stents are available without, with partial and complete silicone cover.
• Stent without, with partial or complete silicone cover• Atraumatic ends• Memory effect of Nitinol material – high radial force and flexibility• Radiopaque tantalum markers• Delivery system
Length 1800 mm, TTS Ø 2.8 mm / 8.5 French Accepts guide wire 0.035 inch
biliary duct
creating stability 10
aixstent®
www.leufen-medical.de
The self-expandable Nitinol stents with laser cut design are used to bridge malignant stenoses in the biliary duct. The biliary duct stents are preloaded on the TTS (through-the-scope) delivery system and are placed through the working channel of the endoscope. The delivery system is introduced into the biliary duct through the papilla under visual and x-ray control. The special laser cut design of the stent guarantees a precise handling and allows an accurate release without stent shortening. The transparent material of the delivery system allows a precise and reliable stent placement under endoscopic view. Three tantalum radiopaque markers on each stent end provide a good over-view and security for the stent release.
• Laser cut design - exact positioning without stent shortening• Defined high radial force at stent center, soft ends• Stent without cover• Radiopaque tantalum markers• Delivery system
Length 1800 mm, TTS Ø 2.8 mm / 8.5 French Accepts guide wire 0.035 inch
aixstent · biliary duct · laser cut design · no cover
REF Total Length Length Cover Ø Middle Ø Ends381-10-040 40 without 10 10381-10-060 60 without 10 10381-10-080 80 without 10 10381-10-100 100 without 10 10
biliary duct laser cut
11
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
aixstent · biliary duct · percutaneous · no cover
REF Total Length Length Cover Ø Middle Ø Ends311-10-040 40 without 10 10311-10-060 60 without 10 10311-10-080 80 without 10 10
aixstent · biliary duct · percutaneous · partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends312-10-040 40 30 10 10312-10-060 60 50 10 10312-10-080 80 70 10 10
aixstent · biliary duct · laser cut · percutaneous · no cover
REF Total Length Length Cover Ø Middle Ø Ends391-10-040 40 without 10 10391-10-060 60 without 10 10391-10-080 80 without 10 10
In some cases the retrograde approach to the biliary duct (ductus choledochus) via the papilla is not possible. To address this indication, we developed a delivery system which enables a stent placement via a percutaneous technique. A prior performed percutaneous cholangiography informes about the position and the extent condition of the stenosis in the biliary duct system. The guiding stability of the new braided delivery system guarantees a precise and reliable stent placement under endoscopic view and in fluoroscopy. The self-expandable Nitinol stents for the biliary duct in percutaneous technique are available without and with partial silicone cover.
• Stent without and with partial silicone cover• Stent design wire woven – atraumatic ends• Stent design laser cut – precise stent positioning• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Percutaneous delivery system
Length 500 mm, OTWØ 2.8 mm / 8.5 FrenchAccepts guide wire 0.035 inch
biliary duct percutaneous
creating stability 12
aixstent®
www.leufen-medical.de
aixstent · hilus biliary duct · laser cut design · no cover
REF Total Length Length Cover Ø Middle Ø Ends321-08-080 80 without 8 8321-08-100 100 without 8 8321-08-120 120 without 8 8
guidewire · Nitinol
REF Total Length Diameter901-21-400 4000 0,021“
The self-expandable Nitinol laser cut stent is used to drain stenoses in the area of the hilus by Klatskin tumour. The hilus biliary duct stents are preloaded on the TTS (through-the-scope) 5 French delivery system so that two stents can be introduced simultaneously into the biliary hilum area through the papilla under visual and x-ray control. The braided material of the new 5 French delivery system guarantees a precise handling and allows an accurate and reliable stent placement under fluoroscopy.
• Exact positioning without stent shortening• Defined high radial force at stent center, soft ends• Stent without cover• Laser cut stent design• Radiopaque tantalum markers• Delivery system
Length 1800 mm, TTS Ø 1.67 mm / 5 French Accepts guide wire 0.021 inch
hilus biliary duct laser cut – 5 F catheter
13
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
The self-expandable Nitinol stents with laser cut design are used to bridge malignant stenoses in the pancreatic ducts. The pancreatic duct stents are preloaded on the new 5 French TTS (through-the-scope) delivery system and are placed through the working channel of the endoscope. The delivery system is introduced into the pancreatic duct through the papilla under visual and x-ray control. The special laser cut design of the stent guarantees a precise handling and allows an accu-rate release without stent shortening. The guiding stability of the new braided 5 French delivery system guarantees a precise and reliable stent placement. Three tantalum markers at each stent end provide a good overview and security for the stent release.
• Exact positioning without stent shortening• Defined high radial force at stent center, soft ends• Stent without cover• Laser cut stent design• Radiopaque tantalum markers• Delivery system
Length 1800 mm, TTS Ø 1.67 mm / 5 French Accepts guide wire 0.021 inch
aixstent · pancreatic duct stent · laser cut design · no cover
REF Total Length Length Cover Ø Middle Ø Ends341-06-040 40 without 6 6341-06-060 60 without 6 6341-08-040 40 without 8 8341-08-060 60 without 8 8
guidewire · Nitinol
REF Total Length Diameter901-21-400 4000 0,021“
pancreatic ductlaser cut – 5 F catheter
creating stability 14
aixstent®
www.leufen-medical.de
The new pancreas-pseudocyst stents are used to drain liquid out of the pseudocyst into the stomach. The diabolo design of the stent prevents a migration into the stomach or the pseudocyst.The pseudocyst stents are preloaded on the new developed braided 10 French TTS (through-the-scope) delivery system and are placed through the working channel of the endoscope. The three radiopaque tantalum markers at each end of the pseudocyst stent assure an excel-lent visibility under radiologic control.
• Stent with complete silicone cover• Diabolo design with atraumatic ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Delivery system
Length 2300 mm, TTS Ø 3.3 mm / 10 French Accepts guide wire 0.035 inch
aixstent · pseudocyst · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends333-10-030 30 30 10 25333-15-030 30 30 15 25
pseudocyst
15
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
aixstent · colon rectum · no cover
REF Total Length Length Cover Ø Middle Ø Ends401-30-080 80 without 30 36401-30-100 100 without 30 36
aixstent · colon rectum · partial silicone cover
REF Total Length Length Cover Ø Middle Ø Ends402-30-080 80 50 30 36402-30-100 100 70 30 36
The self-expandable Nitinol stents for the bridging of colon and rectum strictures are preloaded on the OTW (over-the-wire) delivery system. The special adapted stent form corresponds perfectly to the anatomy of the colon and rectum, which reduces the risk of stent migration. The colon and rectum stents are pre-mounted on the reloadable delivery system. For a precise positioning, the stent can be retracted into the delivery system during the procedure and thus re-positioned. The excellent radiopacity of the tantalum markers makes the stent clearly visible in fluoroscopy.
• Stent without and with partial silicone cover• Atraumatic ends• Special tulip design prevents migration• High tensile, dark colored extraction threads on both ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Reloadable delivery system
Length 1100 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
colon rectumintestinal – OTW
creating stability 16
aixstent®
www.leufen-medical.de
The self-expandable Nitinol stents for dilation of anastomotic strictures in the colon and rectum are preloaded on the OTW (over-the-wire) delivery system. Their special adapted form corresponds perfectly to the anatomy of the colon and rectum, which reduces the risk of stent migration. The anastomosis colon and rectum stents are pre-mounted on the reloadable delivery system. For a precise positioning, the stent can be retracted into the delivery system during the procedure and thus re-positioned. The excellent radiopacity of the tantalum markers makes the stent clearly visible in fluoroscopy.
• Stent with complete silicone cover• Atraumatic ends• Special tulip design prevents migration• High tensile, dark colored extraction threads on both ends• Memory effect of Nitinol material – high radial force• Radiopaque tantalum markers• Reloadable delivery system
Length 1100 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aixstent · colon rectum anastomosis · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends403-20-060 60 60 20 26403-30-060 60 60 30 36
colon rectum anastomosis
17
aixstent®
Errors and technical modification subject to change. All dimensions in mm.
The 0.021 inch single use guide wire is used to complement the new 5 French stent delivery systems for the hilum and the pancreatic duct stents. The Teflon-coating reduces considerably the frictional resistance. The high guiding stability is achieved by an inner core made of a Nitinol monofilament. The distal wire tip is formed as a flexible, atraumatic coil, which is characterized by an excellent radiopacity. The 0.021 inch guide wire is preloaded into a spiral dispenser. The lubricity of the guide wire can be further significantly improved when the dispenser is flushed with sterile saline solution and thus covering the guide wire completely with liquid.
• Kink and guiding stability by Nitinol core• Very good gliding properties of PTFE-coating• Highly flexible, radiopaque tip• Individually sealed in a sterile peel-pack• Supplied in a dispenser with an inserter
guide wire0.021“
aixstent · guide wire
REF Description Ø Length Unit901-21-400 Nitinol color black 0.021 inch / 0,53 mm 4000 mm 01 pc
creating stability 18
aerstent®
www.leufen-medical.de
Leufen Medical offers a huge variety of self-expandable tracheal and bronchial stents with diameters from 10 to 22 mm and lengths from 20 to 80 mm. The special end design and the strong radial force keep the stents in position and avoid migration. All tracheal and bronchial stents are pre-mounted on the reloadable delivery system. For a precise positioning, the stent can be retracted into the delivery system during the procedure.
• Stent with complete silicone cover• Atraumatic ends• Memory effect of Nitinol material – high radial force and flexibility• Reloadable delivery system
Length 600 mm, OTW Ø 6 mm / 18 French (stents-Ø 10, 12 and 14 mm) Ø 8 mm / 24 French (stents-Ø 16, 18, 20 and 22 mm) Accepts guide wire 0.035 inch
aerstent · trachea bronchus · complete silicone cover
REF Total Length Length Cover Ø Middle Ø Ends503-10-020 20 20 10 12503-10-030 30 30 10 12503-12-020 20 20 12 14503-12-040 40 40 12 14503-14-020 20 20 14 16503-14-030 30 30 14 16503-14-040 40 40 14 16503-16-030 30 30 16 18503-16-040 40 40 16 18503-16-050 50 50 16 18503-16-060 60 60 16 18503-16-080 80 80 16 18503-18-030 30 30 18 20503-18-040 40 40 18 20503-18-050 50 50 18 20503-18-060 60 60 18 20503-18-080 80 80 18 20503-20-040 40 40 20 22503-20-060 60 60 20 22503-20-080 80 80 20 22503-22-060 60 60 22 24
trachea bronchustrachea bronchus
19
aerstent®
Errors and technical modification subject to change. All dimensions in mm.
The new y carina stent is used to bridge benign or malignant stenosis in the trachea and in the right or left bronchus. The delivery system is equipped with a one-threat mechanism for delivery. In addition to the 16 and 20 mm diameters, you can now find more configurations in 18 mm diameter with a bronchus in 12 or 14 mm. The y carina stent is preloaded on a 24 F / 8 mm delivery system. For the implantation of the y carina the use of a rigid intubation using a tracheoscope or a bronchoscope with an inner diameter of minimum 10 mm is recommended.
• Stent with complete PU cover, except right bronchus 5 mm without cover
• Atraumatic ends• Anatomical correct conical design• Memory effect of Nitinol material – high radial force and flexibility• Radiopaque tantalum markers• Delivery system
Length 600 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aerstent · y carina · complete PU cover (except right bronchus 5 mm without cover)
REF Trachea Bronchus right Bronchus left512-16-040 Ø 16 L 40 Ø 12 L 20 Ø 12 L 30512-18-040 Ø 18 L 40 Ø 12 L 20 Ø 12 L 30512-18-050 Ø 18 L 50 Ø 14 L 20 Ø 14 L 30512-20-050 Ø 20 L 50 Ø 14 L 20 Ø 14 L 30522-16-040 Ø 16 L 40 Ø 12 L 15 Ø 12 L 30522-18-040 Ø 18 L 40 Ø 12 L 15 Ø 12 L 30522-18-050 Ø 18 L 50 Ø 14 L 15 Ø 14 L 30522-20-050 Ø 20 L 50 Ø 14 L 15 Ø 14 L 30
y carina
creating stability 20
aerstent®
www.leufen-medical.de
The j carina stent is used to bridge an anastomotic leakage after pneu-monectomy. Because of the matter of urgency we offer you different sizes of the j carina stents. The j carina stent is pre-mounted on the reloadable delivery system. For correction of the stent position the stent can be reloaded into the delivery system during the procedure.
• Stent with complete silicone cover• Atraumatic ends• Memory effect of Nitinol material – high radial force and flexibility• Radiopaque tantalum markers• Reloadable delivery system
Length 600 mm, OTW Ø 8 mm / 24 French Accepts guide wire 0.035 inch
aerstent · j carina · complete silicone cover
REF Trachea Ø Trachea Length Bronchus Ø Bronchus Length533-16-030 16 30 12 30533-18-040 18 40 14 30533-20-050 20 50 14 30
j carina
21
aerstent®
Errors and technical modification subject to change. All dimensions in mm.
The 0.035 inch single use guide wire is used to complement the delivery systems of the aerstents® product line. For the distinction of the right and left main bronchus during the procedure, the guide wires are color-coded. The high guiding stability is achieved by an inner core made of a Nitinol monofilament. The distal wire tip is formed as a flexible, atrau-matic coil, which is characterized by an excellent radiopacity. The 0.035 inch guide wire is preloaded into a spiral dispenser. The lu-bricity of the guide wire can be further significantly improved when the dispenser is flushed with sterile saline solution and thus covering the guide wire completely with liquid.
• Kink and guiding stability by Nitinol core• Very good gliding properties of PTFE-coating• Highly flexible, radiopaque tip• Individually sealed in a sterile peel-pack• Supplied in a dispenser with an inserter
guide wire0.035“
aerstent · guide wire
REF Description Ø Length Unit901-35-180 Nitinol color black 0.035 inch / 0,89 mm 1800 mm 01 pc902-35-180 Nitinol color black / white 0.035 inch / 0,89 mm 1800 mm 01 pc
22
Precision up to the finest detail
Each patient has his own history. Each and every diagnosis is just as individual.That‘s why Leufen Medical offers a wide range of stents in different lengths and diameters.At our head office in Aachen, we are constantly developing new products and optimizing designs and materials. We also emphasize perfection for certification and quality control.As a result, all our products are of highest workmanship: Quality, made in Germany.
www.leufen-medical.de creating stability
stents Made in Germany
Leufen Medical GmbH · Wilhelmstraße 79 · D - 52070 Aachen Fon +49 (0)2 41 55 96 77 00 [email protected] +49 (0)2 41 55 96 77 11 www.leufen-medical.de Stat
us 1
1 / 1
2 E