Stephenson Environmental Management Australia ANNUAL EMISSION SURVEY 2019 - FURNACE STACK (EPA ID #1) BITUMINOUS PRODUCTS PTY LTD REVESBY, NSW PROJECT NO.: 7005/F/S25399/19 DATES OF SURVEY: 26 JULY 2019 DATE OF ISSUE: 21 AUGUST 2019
Transcript
Page 1: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

Stephenson Environmental Management Australia

ANNUAL EMISSION SURVEY 2019 - FURNACE STACK (EPA ID #1)

BITUMINOUS PRODUCTS PTY LTD

REVESBY, NSW

PROJECT NO.: 7005/F/S25399/19

DATES OF SURVEY: 26 JULY 2019

DATE OF ISSUE: 21 AUGUST 2019

Page 2: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

Stephenson Environmental Management Australia Peter W Stephenson & Associates Pty Ltd

ACN 002 600 526 (Incorporated in NSW)

ABN 75 002 600 526

52A Hampstead Road

Auburn NSW 2144 Australia

Tel: (02) 9737 9991

E-Mail: [email protected]

ANNUAL EMISSION SURVEY 2019 - FURNACE STACK (EPA ID #1)

BITUMINOUS PRODUCTS PTY LTD

REVESBY, NSW

PROJECT NO.: 7005/F/S25399/19

DATE OF SURVEY: 26 JULY 2019

DATE OF ISSUE: 21 AUGUST 2018

P W STEPHENSON

J WEBER

M KIMBER

Page 3: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA TOC I 7005/F/S25399/19

TABLE OF CONTENTS

1 INTRODUCTION .......................................................................................................1

2 LICENCE AND REGULATORY LIMITS .............................................................................2

3 PRODUCTION CONDITIONS .......................................................................................3

4 EMISSION TEST RESULTS .............................................................................................4

4.1 INTRODUCTION ............................................................................................................... 4

4.2 TOTAL SOLID PARTICULATE MATTER (TSP) ........................................................................ 4

4.3 OXIDES OF NITROGEN (NOX) .......................................................................................... 4

4.4 SULFUR TRIOXIDE/SULFURIC ACID MIST (SO3/H2SO4) ...................................................... 4

4.5 VOLATILE ORGANIC COMPOUNDS (VOCS) ................................................................... 4

5 CONCLUSIONS ........................................................................................................6

6 TEST METHODS ........................................................................................................7

6.1 EXHAUST GAS VELOCITY AND TEMPERATURE .................................................................... 7

6.2 CONTINUOUS GASEOUS ANALYSIS .................................................................................. 7

6.3 SULFUR TRIOXIDE/SULFURIC ACID MIST (SO3/H2SO4) ...................................................... 7

6.4 TOTAL SOLID PARTICULATES (TSP) ................................................................................... 7

6.5 VOLATILE ORGANIC COMPOUNDS (VOCS) ................................................................... 8

6.6 ACCURACY ................................................................................................................... 8

APPENDIX A – EMISSION TEST RESULTS .................................................................................... I

APPENDIX B – NATA EMISSION TEST REPORT INCLUDING CERTIFICATES OF ANALYSIS .................... I

APPENDIX C – CALIBRATION DETAILS ..................................................................................... I

APPENDIX D – SAMPLE LOCATIONS ........................................................................................ I

TABLE OF TABLES

TABLE 2-1 EPA ID POINT 1 MONITORING REQUIREMENTS AND EMISSION CONCENTRATION LIMITS ................. 2

TABLE 4-1 AVERAGE EMISSION CONCENTRATION TEST RESULTS –FURNACE STACK EPA ID 1 ......................... 5

TABLE 6-1 ESTIMATION OF MEASUREMENT UNCERTAINTY .............................................................................. 8

TABLE OF TABLES – APPENDICES

TABLE A-1 DETAILED EMISSION TEST RESULTS – FURNACE STACK - TSP & SO3/H2SO4 ..................................... II

TABLE C-1 INSTRUMENT CALIBRATION INFORMATION .................................................................................... II

TABLE OF FIGURES – APPENDICES

FIGURE D-1 SAMPLE LOCATION – EPA ID POINT 1 ...................................................................................... II

Page 4: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 1 7005/F/S25399/19

1 INTRODUCTION

Stephenson Environmental Management Australia (SEMA) was requested by Bituminous Products Pty Ltd to assess the emission from the Furnace and Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW).

The facility is licensed by the Office of Environment and Heritage (OEH) under Environment Protection Licence (EPL) No. 5267.

The objectives of the tests were:

To monitor the emission from the stack, EPA ID Point 1 (Furnace Stack) in accordance with Condition M2.1 in EPL 5267,

Determine whether the emission concentrations are in compliance with the concentration limits as outlined in Condition L3.3,

Report the findings of the survey in a report.

Refer to Section 2 for further details on the monitoring requirements and concentration limits under the EPL.

The stack emission was assessed for the following components:

Exhaust Gas Velocity, Volume and Temperature

Total Solid Particulate Matter (TSP)

Sulfur Trioxide/Sulfuric Acid Mist (SO3/H2SO4)

Oxides of Nitrogen (NOx) (as Nitrogen Dioxide (NO2))

Volatile Organic Compounds (VOCs).

The emission tests were undertaken on 26 July 2019 on the discharge stack serving the EPA ID Point 1.

Page 5: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 2 7005/F/S25399/19

2 LICENCE AND REGULATORY LIMITS

The stacks at Bituminous Products Pty Ltd are licensed by the NSW OEH under EPL No. 5267 which specifies the monitoring requirements and concentration limits from the stacks. Table 2-1 summarises the EPL monitoring requirements and the concentration limits for EPA ID Point 1. The reference conditions pertaining to the concentration limits are specified in Condition L3.3 of the EPL and are outlined under the respective concentration limit tables.

TABLE 2-1 EPA ID POINT 1 MONITORING REQUIREMENTS AND EMISSION CONCENTRATION LIMITS

Parameter Units Frequency Sampling Method

100 Percentile Concentration

Limit (ID 1)

Nitrogen Oxides mg/m3 Annual TM-11 350

Solid Particles mg/m3 Annual TM-15 50

Sulfuric Acid Mist and Sulfur Trioxide

mg/m3 Annual TM-3 100

Volatile Organic Compounds mg/m3 Annual TM-34 40

Dry gas density kg/m3 Annual TM-4 --

Moisture % Annual TM-23 --

Molecular weight of stack gases g/g.mole Annual TM-23 --

Oxygen % Annual TM-25 --

Temperature oC Annual TM-2 --

Velocity m/s Annual TM-2 --

Volumetric Flow rate m3/s Annual TM-2 --

Reference Conditions:

Nitrogen Oxides, Solid Particles, SO3/H2SO4, VOCs: Dry 273oK, 101.3 kPa, 3% O2

Key:

mg/m3 = milligrams per cubic metre @ 0oC and 1 atmosphere

kg/m3 = kilograms per cubic metre

% = percent

g/g.mole = grams per gram mole

oC = degrees Celsius

m/s = metres per second

m3/s = cubic metres per second

-- = no limit in EPL

TM = Test method

SO3/H2SO4 = Sulfuric Acid Mist and Sulfur Trioxide

VOC = Volatile Organic Compounds

kPa = kilopascals

K = Kelvin

Page 6: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 3 7005/F/S25399/19

3 PRODUCTION CONDITIONS

Bituminous Products Pty Ltd personnel considered the facility was operating under typical conditions on the day of testing.

The production data supplied to SEMA for the day of testing on 26 July 2019 was:

Production was normal activities, with the blowing plant containing Industrial Grade Bitumen 60/18.

Page 7: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 4 7005/F/S25399/19

4 EMISSION TEST RESULTS

4.1 INTRODUCTION

SEMA completed the sampling for all tested parameters and analysis of flow, temperature, moisture, SO3/H2SO4, NOx and TSP. SEMA is NATA accredited for this sampling and analysis, Accreditation No. 15043. Refer to SEMA’s Emission Test Report No. 7005/F, Appendix B, for a summary of results and associated certificates of analysis including SEMA Particle Test Report No. 2136.

Analysis for VOCs was performed by the NATA accredited (NATA No. 3726) TestSafe Laboratories, Report No 2019-3488. Analysis for SO3/H2SO4 was performed by the NATA accredited (NATA No. 825) ALS Environmental Newcastle, Report No. EN1905275.

The stack emission test results are summarised in Table 4-1 and detailed in Appendix A. Appendix C details the calibration of measurement instruments. Refer Appendix D for sample locations.

4.2 TOTAL SOLID PARTICULATE MATTER (TSP)

The measured Furnace Stack TSP emission concentrations, corrected to 3% O2, were 9.2 milligrams per cubic metre (mg/m3) for Run 1 and 9.5 mg/m3 for Run 2. The average TSP emission concentration (corrected to 3% O2) was 9.4 mg/m3. Refer to Appendix A for detailed results.

4.3 OXIDES OF NITROGEN (NOX)

The Furnace Stack one-hour average NOx (expressed as NO2) emission concentration (corrected to 3% O2) was 114 ppm (234 mg/m3) during the sampling period. Refer Table 4-1.

4.4 SULFUR TRIOXIDE/SULFURIC ACID MIST (SO3/H2SO4)

The measured Furnace Stack SO3/H2SO4 emission concentrations, corrected to 3% O2, were less than the limit of detection for the analytical method of 4.6 mg/m3 for run 1 and less than 4.8 mg/m3 for run 2, thus the average SO3/H2SO4 emission concentration was less than 4.7 mg/m3. Refer Table 4-1 and Appendix A for details.

4.5 VOLATILE ORGANIC COMPOUNDS (VOCS)

There were nil detections of VOCs emission concentrations measured in the Furnace Stack with all analysis recording below the level of detection for the analytical method.

Page 8: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 5 7005/F/S25399/19

TABLE 4-1 AVERAGE EMISSION CONCENTRATION TEST RESULTS –FURNACE STACK EPA ID 1

Parameter Units of Measure

Average Emission Conc. EPA ID 1

EPL Conc. Limit

26 July 2019

Nitrogen Oxides mg/m3@ 3% O2 234 350

Solid Particles mg/m3@ 3% O2 9.4 50

Sulfuric acid mist/Sulfur trioxide mg/m3@ 3% O2 <4.7 100

Volatile Organic Compounds * mg/m3@ 3% O2 <4.0 40

Dry gas density kg/m3 1.32 --

Moisture % 3.2 --

Molecular weight of stack gases g/g.mole 29.6 --

Oxygen % 9.3 --

Temperature oC 681 --

Velocity m/s 9.3 --

Volumetric exhaust gas flow-rate m3/s 0.19 --

Key:

EPL = Environment Protection Licence

Conc. = concentration

VOCs = Volatile Organic Compounds

* = The POEO (Clean Air) Regulation requires VOCs to be reported as n-propane equivalent. All measured VOC emissions are reported as n-propane equivalent unless otherwise stated.

-- = No limit

< = Less than the limit of detection for the analytical method

% = percent

ou = odour units oC = degrees Celsius

g/g.mole = grams per gram mole

kg/m3 = kilograms per cubic metre

mg/m3 = milligrams per cubic metre @ 0oC and 1 atmosphere

m/s = metres per second

m3/s = cubic metres per second

Page 9: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 6 7005/F/S25399/19

5 CONCLUSIONS

From the data presented and test work conducted during typical production cycles, the following conclusions can be drawn:

FURNACE STACK – EPA ID POINT 1

All emission parameters measured were in compliance with the EPL emission concentration limits set out in Condition L3.3 of EPL 5267.

Particulate matter emission concentration (TSP) averaged 9.4 mg/m3 at 3% O2 which was in compliance with the EPL limit of 50 mg/m3.

The NOx emission concentration one-hour average was 234 mg/m3 at 3% O2, expressed as NO2, which was in compliance with the EPL Limit of 350 mg/m3.

The SO3/H2SO4 emission concentration averaged less than 4.7 mg/m3 at 3% O2, which was in compliance with the EPL limit of 100 mg/m3.

The VOC emission concentration averaged less than 4.0 mg/m3 (the limit of detection for the analytical method) at 3% O2 which was in compliance with the EPL limit of 40 mg/m3 (expressed as n-propane).

Page 10: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 7 7005/F/S25399/19

6 TEST METHODS

6.1 EXHAUST GAS VELOCITY AND TEMPERATURE

(OEH NSW TM-1 & 2)

Velocity profiles were obtained across the stack utilising an Airflow Developments Ltd. S-type pitot tube and manometer. The exhaust gas temperature was measured using a Digital thermometer (0-1200oC) connected to a chromel/alumel (K-type) thermocouple probe.

6.2 CONTINUOUS GASEOUS ANALYSIS

(OEH NSW TM- 4 & 11)

Sampling and analysis of exhaust gas were performed using a Stephenson Environmental Management Australia mobile combustion and environmental monitoring laboratory. Emission gases were distributed to the analysers via a manifold. Flue gas from the stack was pumped continuously. The following components of the laboratory were relevant to this work:

Oxides of Nitrogen Testo 350XL

Oxygen Testo 350XL

Calibration BOC Special Gas Mixtures relevant for each analyser. Instrument calibrations were performed at the start and finish of sampling at each location.

QA/QC Calibration (Zero/Span) checks

Sample line integrity calibration check

6.3 SULFUR TRIOXIDE/SULFURIC ACID MIST (SO3/H2SO4)

(OEH NSW TM- 3)

SO3/H2SO4 were sampled isokinetically and drawn through a glass probe into four Greenburg Smith impingers in series. The first and second impingers in the train contained 100 ml of 80% isopropanol; the third was empty and the fourth contained silica gel. The impinger train was mounted in an ice water bath. Analysis was performed by the NATA accredited laboratories of ALS Environmental.

6.4 TOTAL SOLID PARTICULATES (TSP)

(OEH NSW TM- 15)

The Alundum Thimble Filtration Method of utilising filtration equipment manufactured by Saint Gobain Ceramics was used for the particulate matter sampling. Samples were collected at isokinetic rates from multipoint traverses across the discharge stack, in accordance with Australian Standard (AS) 4323, 1995 Parts 1 & 2 and OEH NSW Test Method 15.

Page 11: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA PAGE 8 7005/F/S25399/19

6.5 VOLATILE ORGANIC COMPOUNDS (VOCS)

(OEH NSW TM-34)

A sample of stack air is drawn onto a carbon tube and analysed using Gas Chromatography/Mass Spectrometry (GC/MS) performed by the NATA accredited laboratory TestSafe Australia, accreditation number, 3726.

6.6 ACCURACY

All results are quoted on a dry basis. SEMA has adopted the following (Table 6-1) uncertainties for various stack testing methods.

TABLE 6-1 ESTIMATION OF MEASUREMENT UNCERTAINTY

Pollutant Methods Uncertainty

Moisture AS4323.2, TM-22, USEPA 4 25%

Nitrogen Oxides TM-11, USEPA 7E 15%

Oxygen and Carbon Dioxide TM-24, TM-25, USEPA 3A 1% actual

Particulate > 20 mg/m3 TM-15, AS4323.2, USEPA 5 & 17 15%

Particulate < 20 mg/m3 TM-15, AS4323.2, USEPA 5 & 17 50%

Sulfur Trioxide/Sulfuric Acid Mist (SO3/H2SO4)

TM-3, USEPA 8 20%

Velocity AS4323.1, TM-2, USEPA 2 5%

Volatile Organic Compounds (adsorption tube)

TM-34, USEPA 18 25%

Key:

Unless otherwise indicated the uncertainties quoted have been determined @ 95% level of Confidence level (i.e. by multiplying the repeatability standard deviation by a co-efficient equal to 1.96) (Source – Measurement Uncertainty)

Sources:

Measurement Uncertainty – implications for the enforcement of emission limits by Maciek Lewandowski (Environment Agency) & Michael Woodfield (AEAT) UK

Technical Guidance Note (Monitoring) M2 Monitoring of stack emissions to air Environment Agency Version 3.1 June 2005.

Note:

ISO 9096 is for 20-1000 mg/m3- which AS4323.2 is based on. Note DSEN 13284-1 testing for < 5 mg/m3 correlates to 5 mg/m3 with most quoted uncertainties of + 5.3 mg/m3 @ 6.4 mg/m3. From Clean Air Engineering in the United States the lowest practical limit of USEPA M5 is 5 mg/m3 under lab conditions.

Page 12: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX A-I 7005/F/S25399/19

APPENDIX A – EMISSION TEST RESULTS

Glossary:

% = percent oC = Degrees Celsius

am³/min = cubic metre of gas at actual conditions per minute

Normal Volume (m³) = cubic metre at 0°C and 760 mm pressure and 1 atmosphere

am³ = cubic metre of gas at actual conditions

g/g mole = grams per gram mole

g/s = grams per second

hrs = hours

kg/m3 = kilograms per cubic metre

kPa = kilo Pascals

m2 = square metre

m/s = metre per second

m³/sec = cubic metre per second at 00C and 1 atmosphere

mg = milligrams

mg/ m³ = milligrams per cubic metre at 0ºC and 1 atmosphere

O2 = Oxygen

Abbreviations of Parameters

PM10 = Particulate Matter less than 10 microns

SO3/H2SO4 = Sulfur Trioxide/ Sulfuric Acid Mist

TSP = Total Solid Particulates

Abbreviations of Personnel

PWS = Peter W Stephenson

JW = Jay Weber

Page 13: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX A-II 7005/F/S25399/19

TABLE A-1 DETAILED EMISSION TEST RESULTS – FURNACE STACK - TSP & SO3/H2SO4

Emission Test Results TSP TSP SO3/H2SO4 SO3/H2SO4

Project Number 7005 7005 7005 7005

Project Name Bituminous Bituminous Bituminous Bituminous

Test Location Furnace Furnace Furnace Furnace

Date 26-Jul-19 26-Jul-19 26-Jul-19 26-Jul-19

RUN 1 2 1 2

Sample Start Time (hrs) 10:08 11:28 10:08 11:28

Sample Finish Time (hrs) 11:08 12:28 11:08 12:28

Sample Location (Inlet/Exhaust) Exhaust Exhaust Exhaust Exhaust

Stack Temperature (oC) 654 707 654 707

Stack Cross-Sectional area (m2) 0.076 0.076 0.076 0.076

Average Stack Gas Velocity (m/s) 9.1 9.3 9.1 9.3

Actual Gas Flow Volume (am3/min) 41 42 41 42

Total Normal Gas Flow Volume (m3/min)

12 11 12 11

Total Normal Gas Flow Volume (m3/sec)

0.2 0.19 0.2 0.19

Total Stack Pressure (kPa) 102.1 102.1 102.1 102.1

Analysis TSP TSP SO3/H2SO4 SO3/H2SO4

Method TM-15 TM-15 TM-3

(USEPA M8) TM-3

(USEPA M8)

SEMA Lab Number 727576 727577 727580 727581

Mass In Sample (mg) 4.03 4.0 < 2 < 2

Air Volume Sampled (am3) 0.706 0.686 0.696 0.677

Normal Sample Volume (m3) 0.672 0.654 0.663 0.64

Concentration at Stack O2 (mg/m3) 5.99 6.15 < 3 < 3.1

Concentration at 3% O2 (mg/m3) 9.2 9.5 < 4.6 < 4.8

Mass Emission Rate (g/s) 0.00120 0.00120 < 0.0006 < 0.00059

Moisture Content (% by volume) 2.5 3.7 2.6 4.1

Molecular Weight Dry Stack Gas (g/g-mole)

29.7 29.7 29.7 29.7

Dry Gas Density (kg/m3) 1.33 1.33 1.33 1.33

EPL Limit (mg/m3) 50 50 100 100

Isokinetic Sampling Rate (%) 102 103 100 101

Sample Storage Period 3 months 3 months Consumed in Analysis

Consumed in Analysis

Sampling Performed by JW, PWS JW, PWS JW, PWS JW, PWS

Sample Analysed by (Laboratory) SEMA SEMA ALS ALS

Calculations Entered by JW JW JW JW

Calculations Checked by PWS PWS PWS PWS

Page 14: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-I 7005/F/S25399/19

APPENDIX B – NATA EMISSION TEST REPORT INCLUDING CERTIFICATES OF

ANALYSIS

Page 15: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-II 7005/F/S25399/19

Page 16: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-III 7005/F/S25399/19

Page 17: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-IV 7005/F/S25399/19

Page 18: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-V 7005/F/S25399/19

Page 19: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-VI 7005/F/S25399/19

Page 20: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-VII 7005/F/S25399/19

Page 21: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-VIII 7005/F/S25399/19

Page 22: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-IX 7005/F/S25399/19

Page 23: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-I 7005/F/S25399/19

Page 24: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-II 7005/F/S25399/19

Page 25: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-I 7005/F/S25399/19

Page 26: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-II 7005/F/S25399/19

Page 27: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-III 7005/F/S25399/19

Page 28: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX B-IV 7005/F/S25399/19

Page 29: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX C-I 7005/F/S25399/19

APPENDIX C – CALIBRATION DETAILS

Page 30: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX C-II 7005/F/S25399/19

TABLE C-1 INSTRUMENT CALIBRATION INFORMATION

SEMA Asset No.

Equipment Description Date Last

Calibrated Calibration Due

Date

704 Stopwatch 05-Jul-19 05-Jan-20

872 Gas Meter 14-Mar-19 14-Mar-20

908 Gas Meter 21-Mar-17 14-Jun-20

857 Digital Temperature Reader 04-Jul-19 04-Jan-20

720 Thermocouple 04-Jul-19 04-Jan-20

815 Digital Manometer 21-Jan-19 21-Jan-20

613 Barometer 21-Jan-19 21-Jan-20

427 Nozzle TSP Swagelok 2 04-Mar-19 04-Mar-20

407 Nozzle USEPA Metals Set Glass 17-Jan-19 17-Jan-20

726 Pitot 23-Jul-19 23-Jul-2020

Visually inspected On-Site before use

927 Balance Response Check with SEMA Site

Mass

929 Calibrated Site Mass 14-Mar-19 14-Mar-20

946 combustion analyzer 09-Jul-19 09-Jan-20

835 Personal Sampler 14-Mar-19 14-Mar-20

764 TSI THERMAL MASS FLOWMETER 09-Apr-19 09-Sep-19

Gas Mixtures used for Analyser Span Response

Conc. Mixture Cylinder No. Expiry Date

400 ppm 400 ppm 401 ppm

Nitric Oxide Total Oxide Of Nitrogen In Nitrogen Sulphur Dioxide In Nitrogen

ALWB6150 05-May-20

262 ppm 263 ppm 249 ppm

Nitric Oxide Total Oxide Of Nitrogen In Nitrogen Sulphur Dioxide In Nitrogen

ALWB 4441 23-Jun-21

0.099% 9.8%

10.1%

Carbon Monoxide Carbon Dioxide Oxygen In Nitrogen

ALWB 5361 17-Jul-21

Page 31: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX D-I 7005/F/S25399/19

APPENDIX D – SAMPLE LOCATIONS

Page 32: Stephenson - Bituminous Products...Scrubber discharge stacks at their Bituminous Products facility in Revesby, New South Wales (NSW). The facility is licensed by the Office of Environment

BITUMINOUS PRODUCTS PTY LTD FURNACE STACK EMISSION SURVEY

REVESBY, NSW JULY 2019

STEPHENSON ENVIRONMENTAL MANAGEMENT AUSTRALIA APPENDIX D-II 7005/F/S25399/19

FIGURE D-1 SAMPLE LOCATION – EPA ID POINT 1

In the absence of cyclonic flow activity ideal sampling plane conditions will be found to exist at 6-8 duct diameters downstream and 2-3 duct diameters upstream from a flow disturbance. The sampling plane does meet this criterion.

The sampling plane does not comply with the minimum number of access points required. The minimum requirement for the above stack diameter is two four (4) inch access points at 90 degrees to each along the same sampling plane. Additional sample points were used in compliance with AS4323.1 as the sampling plane was non-ideal.

The location of the sampling plane complies with AS4323.1 criteria for temperature, velocity and gas flow profile and therefore is satisfactory for gas flow sampling.

Sampling Plane

Disturbance is a Bend (Reducer)

Disturbance is the Stack Exit/Exhaust

Sample Plane Downstream of Disturbance is 1.5m which is

≥ 6 Duct Diameters

Sample Plane Upstream of Disturbance is 3.0m which is

≥ 2 Duct Diameters

Total Number of Sampling Points is

8

SEMA adopted a total of 12 points

Duct Diameter 0.31m

Flow


Recommended