The Eighteenth KKCNN Symposium on Civil Engineering. Structural Vibration Control Using Semiactive Tuned Mass Damper. Han-Rok Ji , Graduate Student , KAIST, Korea Yeong-Jong Moon, Ph. D. Candidate , KAIST, Korea Chun-Ho Kim, Professor , Joongbu University, Korea - PowerPoint PPT Presentation
19
Structural Dynamics & Vibration Control Lab., KAIST Structural Dynamics & Vibration Control Lab., KAIST 1 Structural Vibration Control Using Semiactive Tuned Mass Damper Han-Rok Ji , Graduate Student, KAIST, Korea Yeong-Jong Moon, Ph. D. Candidate, KAIST, Korea Chun-Ho Kim, Professor, Joongbu University, Korea In-Won Lee, Professor, KAIST, Korea The Eighteenth KKCNN Symposium on Civil Engineering
Transcript
Page 1: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 1

Structural Vibration Control Using Semiactive Tuned Mass Damper

Han-Rok Ji, Graduate Student, KAIST, KoreaYeong-Jong Moon, Ph. D. Candidate, KAIST, KoreaChun-Ho Kim, Professor, Joongbu University, KoreaIn-Won Lee, Professor, KAIST, Korea

The Eighteenth KKCNN Symposium on Civil Engineering

Page 2: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 2

Introduction

Semiactive Tuned Mass Damper

Numerical Analysis

Conclusions

CONTENTS

Page 3: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 3

Introduction

Tuned Mass Damper ― widely used mechanical damping device― Simple and efficient vibration control system ― No external power, energy dissipation, inherent reliability― Restricted performance resulted from the fixed parameters

Semiactive Tuned Mass Damper ― Alternative device of conventional TMD ― Improved control performance with stability of TMD― High robustness and adaptability

Page 4: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 4

Objective

Analytical study on semiactive TMD using MR damper for mitigating the vibration of structures

Application of various semiactive control algorithms to MR damper

Robustness analysis for the semiactive TMD system

Page 5: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 5

Semiactive Tuned Mass Damper

m1

k1

c1

m2

c(t)

x1

x2

k2

m1

gxm

mxx

kkkkk

xx

ccccc

xx

mm

11

00

00

2

1

2

1

22

221

2

1

22

221

2

1

2

1

― Equation of Motion

(1)

SDOF system with semiactive TMD

– Controllable damping device is installed in the place of passive dashpot.– Produce the additional control effect to the primary structure.

Page 6: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 6

)Vu(uucc)u(cc

ucc)u(ccu)u(

)yx(kxczcc

y

)yx(Az)yx(zzyxz

)xx(kycf

ba

ba

ba

nn

0000

1111

0010

1

011

1

c0 c1 k1

k0

c1 c0 k0

k1

Modified Bouc-Wen Model

Bouc-Wen

― modified Bouc-Wen model (Spencer et al., 1997)

(2)

• Dynamic model of MR damper

Page 7: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 7

Semiactive Control Algorithms

― on-off velocity based groundhook control

― on-off displacement based groundhook control

― clipped optimal algorithm

― maximum energy dissipation algorithm

Page 8: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 8

maxVVthen,vvvif 0211

• On-off velocity based groundhook control (Koo et al. 2003)

― Based on velocity of primary system (v1 ) and TMD (v2 )

minVVthen,vvvif 0211

(3)

• On-off displacement based groundhook control (Koo et al. 2003)

(4)

― Based on velocity of primary system (v1 ) and TMD (v2 )

displacement of primary system (x1 )

maxVVthen,vvxif 0211

minVVthen,vvxif 0211

Page 9: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 9

― linear optimal controller and clipped algorithm

Fc : desired damper force by optimal controller

Fd : measured damper force

ddcmax FFFHVV

• Clipped optimal algorithm (Dyke et al, 1996)

(5)

)Fx(HVV dmax

• Maximum energy dissipation algorithm (Jansen and Dyke, 2000)

(6)

― Control voltage is determined so that the structure dissipates the maximum energy

Fd : measured damper force

Page 10: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 10

kg,

,,

M

500100050010005001

mN

.....

..K 610

12120122412

01224

msecN

.........

C

910425841025871528434108431163

gx

• Three-story shear building MR damper

mTMD = 150 kg , kTMD = 36,401 N/m

• Input earthquake excitations

― amplitude scaled El Centro, Hachinohe earthquakes

Numerical Analysis

Page 11: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 11

Value Value

coa 21.0 Nsec/cm a 140 N/cm

cob 3.50 Nsec/cmV b 695 N/cmV

ko 46.9 N/cm 363 cm-2

c1a 283 Nsec/cm 363 cm-2

c1b 2.95 Nsec/cmV A 301

k1 5.00 N/cm n 2

xo 14.3 cm 190 sec-1

• Parameters of MR damper (Spencer et al., 1997)

c0 c1 k1

k0

c1 c0 k0

k1

Modified Bouc-Wen model

Bouc-Wen

― maximum damper force : 1,500 N― minimum voltage : 0 V― maximum voltage : 2.25 V

Page 12: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 12

Response of building model

TMD passive off

passive on

on-offDBG

on-offVBG

clippedoptimal

MEDA

ScaledEl Centro

(PGA 0.10g)

J1 0.38 0.39 0.50 0.35 0.39 0.36 0.39

J2 0.37 0.37 0.52 0.33 0.34 0.32 0.34

J3 0.45 0.47 0.50 0.44 0.44 0.43 0.44

Scaled Hachinohe

(PGA 0.08g)

J1 0.35 0.36 0.51 0.35 0.40 0.36 0.40

J2 0.35 0.35 0.49 0.32 0.39 0.34 0.39

J3 0.38 0.41 0.47 0.36 0.37 0.35 0.37

J1 : normalized peak floor displacementJ2 : normalized peak interstory driftJ3 : normalized peak acceleration

Page 13: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 13

0.2

0.3

0.4

0.5

0.6

TMD passiveoff

passiveon

on-offDBG

on-offVBG

clippedoptimal

MEDA

J₁J₂J₃

0.3

0.35

0.4

0.45

0.5

0.55

TMD passiveoff

passive on on-offDBG

on-offVBG

cl ippedoptimal

MEDA

J₁J₂J₃

― El Centro earthquake ― Hachinohe earthquake

― The efficiency of semiactive TMD is slightly better than that of TMD.

― Passive on mode has the worst performance.

Nor

mal

ized

val

ue

Nor

mal

ized

val

ue

― Evaluation criteria under two earthquakes

Page 14: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 14

Robustness Analysis

• Response with stiffness matrix perturbation

1KK̂

: amount of perturbation

(-15%, -10%, -5%, +5%, +10% and +15%)

― Perturbed stiffness matrix

(7)

― Real structures can have structural uncertainties in many reasons.

― Control performance of TMD is restricted considerably due to off-tuning effect.— Stiffness perturbation is considered to verify the robustness of the semiactive TMD

Page 15: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 15

-0.6

-0.3

0

0.3

0.6

0 5 10 15 20

TMDon-off DBG

-3

-1.5

0

1.5

3

0 5 10 15 20

TMDon-off DBG

Time (sec)

Inte

rsto

ry d

rift

(cm

)A

ccel

erat

ion

(m/s

ec2 )

Time history with +15% stiffness perturbation under Hachinohe earthquake

― The maximum and RMS values with semiactive TMD are reduced compared with that of conventional TMD.

Page 16: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 16

0.2

0.4

0.6

0.8

1

1.2

-15% -10% -5% 0% 5% 10% 15%

TMDon-off DBGon-off VBGclipped optiamalMEDA

Nor

mal

ized

pea

k dr

ift (

J 2)

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

-15% -10% -5% 0% 5% 10% 15%

TMDon-off DBGon-off VBGclipped optiamalMEDA

Nor

mal

ized

pea

k ac

cele

ratio

n (J

3)― Overall performance of semiactive TMD is better than that of TMD.

― Efficient algorithm : on-off DBG control for interstory drift

clipped optimal control for acceleration

― Evaluation criteria under El Centro earthquake

Page 17: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 17

Nor

mal

ized

pea

k dr

ift (

J 2)

Nor

mal

ized

pea

k ac

cele

ratio

n (J

3)

0.2

0.3

0.4

0.5

0.6

0.7

0.8

-15% -10% -5% 0% 5% 10% 15%

TMDon-off DBGon-off VBGclipped optiamalMEDA

0.2

0.3

0.4

0.5

0.6

0.7

0.8

-15% -10% -5% 0% 5% 10% 15%

TMDon-off DBGon-off VBGclipped optiamalMEDA

― Semiactive TMD is superior to conventional TMD.

― On-off DBG and clipped optimal algorithm have sufficient robustness.

― Evaluation criteria under Hachinohe earthquake

Page 18: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 18

― Various semiactive control algorithms are adopted and the performance of each algorithm is evaluated.

― Semiactive TMD system shows slightly better performance than conventional TMD system.

― Analytical study on semiactive TMD with MR damper is performed.

Conclusions

Page 19: Structural Vibration Control  Using Semiactive Tuned Mass Damper

Structural Dynamics & Vibration Control Lab., KAISTStructural Dynamics & Vibration Control Lab., KAIST 19

― Sufficient robustness is obtained under the structural perturbation with semiactive TMD.

― The on-off displacement based groundhook theory and clipped optimal algorithm is appropriate algorithm for semiactive TMD system.


Recommended