+ All Categories
Home > Documents > Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS)...

Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS)...

Date post: 19-Apr-2020
Category:
Upload: others
View: 41 times
Download: 0 times
Share this document with a friend
84
www.dlinkmea.com Structured Cabling Solutions
Transcript
Page 1: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.com

Structured Cabling

Solutions

Page 2: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.com

STRUCTURED CABLING

A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific set of standards.

Structured cabling falls into six subsystems

• Entrance Facilities is where the building interfaces with the outside world.• Equipment Rooms houses equipment which serves the users inside the building or campus.• Telecommunications Rooms connects between the backbone cabling and horizontal cabling subsystems.• Backbone Cabling connects between the entrance facilities, equipment rooms and telecommunication rooms.• Horizontal Cabling connects telecommunications rooms to individual outlets on the floor.• Work-Area Components connects end-user equipment to outlets of the horizontal cabling system

Structured cabling design and installation is governed by a set of standards that specify wiring data centres, offices, and apartment buildings for data or voice communications using copper, fibre cabling and accessories. These standards define how to lay the cabling in various topologies in order to meet the needs of the customer.

Structured Cabling Standards

TIA/EIA-568-A: Commercial Building CablingTIA/EIA-568-A-3: Bundled CablesTIA/EIA-568-A-5: Cat 5e Cabling TIA/EIA-568-BTIA/EIA-568-B.1: Cat 6 CablingTIA/EIA-568-B.2-10: Cat 6A CablingTIA/EIA-568-B.3: Optical Fiber CablingTIA/EIA-569A: Pathways & SpacesTIA/EIA-606: Labelling and RecordingTIA/EIA-607: Grounding & BondingTSB-67: Field TestingTSB-72: Centralized FiberTSB-75: Open Office WiringTSB-95: Additional Guidelines for Cat5e CablingTIA/EIA 568–C: Commercial buildings, and between buildings in campus environments.

Page 3: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.com

COPPER SOLUTIONS

Cat5e UTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Cat5e UTP Keystone Jacks . . . . . . . . . . . . . . . . . . 8

Cat5e UTP Patch Cords . . . . . . . . . . . . . . . . . . . . . 9

CAT5e UTP Loaded Patch Panels. . . . . . . . . . . . 10

CAT5e FTP Cables . . . . . . . . . . . . . . . . . . . . . . . . . 11

CAT5e FTP Outdoor Cables . . . . . . . . . . . . . . . . . 13

CAT5e SFTP Cables. . . . . . . . . . . . . . . . . . . . . . . . 15

CAT5e Shielded Patch Panels. . . . . . . . . . . . . . . 17

CAT6 UTP 23 AWG Cables . . . . . . . . . . . . . . . . . . 18

CAT6 UTP 24 AWG Cables . . . . . . . . . . . . . . . . . . 20

CAT6 UTP Keystones . . . . . . . . . . . . . . . . . . . . . . 22

CAT6 UTP Patch Cords. . . . . . . . . . . . . . . . . . . . . 23

CAT6 UTP Patch Panels . . . . . . . . . . . . . . . . . . . . 24

CAT6 0.5U Loaded Patch Panels. . . . . . . . . . . . . 25

CAT6 Loaded Angled Patch Panels . . . . . . . . . . 26

CAT6 FTP 23 AWG Cables . . . . . . . . . . . . . . . . . . 27

CAT6 FTP 24 AWG Cables . . . . . . . . . . . . . . . . . . 29

CAT6 FTP Double Sheath Outdoor Cables . . . . 31

CAT6 SFTP Cables. . . . . . . . . . . . . . . . . . . . . . . . . 33

CAT6 FTP Keystone Jacks . . . . . . . . . . . . . . . . . . 35

CAT6 STP Patch Cords . . . . . . . . . . . . . . . . . . . . . 36

CAT6 Shielded Patch Panels. . . . . . . . . . . . . . . . 37

CAT6a UTP Cables . . . . . . . . . . . . . . . . . . . . . . . . 38

CAT6a UTP Keystone Jacks . . . . . . . . . . . . . . . . 40

CAT6a UTP Patch Cords. . . . . . . . . . . . . . . . . . . . 41

CAT6a UTP Patch Panels. . . . . . . . . . . . . . . . . . . 42

CAT6a Shielded Cables . . . . . . . . . . . . . . . . . . . . 43

CAT6a FTP Keystone Jacks. . . . . . . . . . . . . . . . . 45

CAT6a Shielded Patch Cords . . . . . . . . . . . . . . . 46

CAT6a Shielded Patch Panels. . . . . . . . . . . . . . . 47

Unloaded Patch Panels . . . . . . . . . . . . . . . . . . . . 48

Voice Patch Panels. . . . . . . . . . . . . . . . . . . . . . . . 49

TABLE OF CONTENTSFaceplates & Modular Inserts . . . . . . . . . . . . . . 50

Keystone Boxes. . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Back Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Modular Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Cable Managers . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Network Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Network LAN Tester . . . . . . . . . . . . . . . . . . . . . . . 56

Velcro Cable Tie . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Cable Stripper . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

FIBER SOLUTIONS

Optic Fiber Cables - Armoured . . . . . . . . . . . . . . 60

Optic Fiber Cables - Unarmoured. . . . . . . . . . . . 61

Optic Fiber Cables - Tight-Buffered . . . . . . . . . . 62

Optic Fiber Cables - FTTH . . . . . . . . . . . . . . . . . . 63

Fiber Patch Cords - Simplex & Duplex . . . . . . . 64

Fiber Optic Components - Pigtails . . . . . . . . . . . 66

Fiber Optic Components | FC Connectors . . . . . 67

Fiber Optic Components | LC Connectors . . . . . 68

Fiber Optic Components | SC Connectors. . . . . 69

Fiber Optic Components | ST Connectors. . . . . 70

Fiber Optic Components | FC Adapters . . . . . . . 71

Fiber Optic Components | LC Adapters . . . . . . . 72

Fiber Optic Components | SC Adapters. . . . . . . 73

Fiber Optic Components | ST Adapters . . . . . . . 74

Fiber Optic Components | Adapter Panels . . . . 75

Fiber Optic Components | LIU Fixed 1U/2U . . . . 76

Fiber Optic Components | LIU Wall Mount . . . 77

Fiber Optic Components | LIU Sliding 1U/2U . . 78

Micro ODF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

PLC Splitter - Rack Mount . . . . . . . . . . . . . . . . . . 80

Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

D-Link Certified Cabling Expert (DCCE) . . . . . . . 82

Technical Services & Support . . . . . . . . . . . . . . 83

Page 4: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.com

Founded in 1986, D-Link is a global leader in the design, manufacture and marketing of advanced networking, broadband, digital, voice and data communications solutions. Following our company motto, "Building Networks for People", D-Link continually meets the global networking and connectivity needs of digital home consumers, small office professionals, small- to medium-sized businesses, and enterprise environments.

A major contributor to our success is our established and expanding network of global distribution and delivery channels that brings products to more than 100 countries every day. We do more than meet the growing demand for computer networking and communications solutions - we fuel it. Our development of global distribution channels in more than 100 countries has resulted in double-digit growth every year for 20 years. D-Link surpassed the $1 billion revenue milestone in 2005, driven by record sales in every geographic region of the world.

INTERTEK

LISTED

CM

US

THIRD

PARTY TESTING

3P

C U US® L

LISTED

ETL is a mark provided by Intertek and ETL Semko. Intertek (www.intertek-etlsemko.com) is a global leader in testing inspection and certification services. They are a Nationally Recognized Testing Laboratory and tests products to UL, CSA and CE standards.

3P Third Party Testing is an independent testing laboratory serving the international cabling and electronic industries. Its main product is certification testing of components for communication cabling, i.e. cables, connecting hardware, patch cords, and permanent links and channels.

Underwriters Laboratories Inc. (www.ul.com) is an independent, nonprofit organization that writes testing standards and tests products for safety and certifies them. UL has developed more than 800 standards for safety, and millions of products and their components are tested to UL’s safety standards.

Benefit from D-Link's 25-years performance warranty applicable to all D-Link Cabling products*.

Copper SolutionsComplete Your Network Infrastructure

with D-Link Structured Cabling Solutions

4 www.dlinkmea.com

Page 5: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.com

Copper Solutions

UTP CABLES

KEYSTONE JACKS

PATCH CORDS

PATCH PANELS

FTP CABLES

CABLE MANAGERS

NETWORK TOOLS

NETWORK LAN TESTER

VELCRO CABLE TIES

CABLE STRIPPER

FACEPLATES & MODULAR INSERTS

KEYSTONE BOXES

BACK BOXES

MODULAR PLUGS

www.dlinkmea.comwww.dlinkmea.com 5

Page 6: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

6

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

CAT5e UTP CABLE

Enhanced performance cable for transmission of high-speeddata, digital and analogue voice and video (RGB)signals on LANs. Supports Gigabit Ethernet (1000 baseT)standard. Operates at bandwidth up to 100MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801Approval:

• Comply with Cat5e specifications• 4-pair unshielded twisted pair (UTP) cable• 24 AWG solid copper conductor• PE insulation• FR PVC Jacket• Packaged in an easy to pull reel in a box for easier installation

SPECIFICATIONS

ORDERING INFORMATION

COLOUR CODE

ELECTRICAL PROPERTIES

KEY FEATURES

Category: 5e UTP Solid cableConductor: 24 AWG Multicore (Solid)Conductor: Bare CopperInsulation: HD-PEMaterial: FR PVCHeat-resistant: 75 degree C maximum (Temperature limited) Cable Diameter: 5 mm nominal

NCB-5EUGRYR-305NCB-5EUBLUR-305

1-23-64-57-8

Characteristic Impedance: Conductor Resistance: Mutual Capacitance: Resistance Unbalance:Capacitance Unbalance:Delay Skew: NVP:

CAT5e UTP 24AWG Solid:305m, GreyCAT5e UTP 24AWG Solid:305m, Blue

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

100±15Ω≤ 9.38Ω/100m<5.6nF/100m5% Max330pF/100m<45ns69%

PART CODE

PAIR NO

DESCRIPTION

COLOUR

PVC SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Page 7: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 7

Cat5

e So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 4 x cable diameter at -20°C ± 1°CPulling Force: 9.5kgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801

Available in easy-pull reel in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS

(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 65.3 62.3 63.8 60.8 63.3 60.3

4 4.1 23.0 56.3 53.3 51.8 48.8 52.2 49.2

8 5.8 24.5 51.8 48.8 45.7 42.7 46.0 43.0

10 6.5 25.0 50.3 47.3 43.8 40.8 43.8 40.8

16 8.2 25.0 47.2 44.2 39.7 36.7 39.0 36.0

20 9.3 25.0 45.8 42.8 37.8 34.8 36.5 33.5

25 10.4 24.3 44.3 41.3 35.8 32.8 33.9 30.9

31.25 11.7 23.6 42.9 39.9 33.9 30.9 31.2 28.2

62.5 17.0 21.5 38.4 35.4 27.9 24.9 21.4 18.4

100 22.0 20.1 35.3 32.3 23.8 20.8 13.3 10.3

Page 8: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

8

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

CAT5e UTP KEYSTONE JACKS

D-Link Category 5e keystone jacks are RJ45 8P 8C 50u’ jackssuitable for 22-26 AWG stranded and solid wire, compatiblewith both 110 & Krone punch down tools. They are availablein universal labels Colour coded for T568A and T568B wiringschemes and fit in high density keystone patch panel. Itsupports IEC 60603-7-4 and complied with ANSI/TIA EIA-568-C.2 standard.

SPECIFICATIONS

ORDERING INFORMATION

RJ45 Jack: Housing: PC, UL94V-0 with Option Color Contact Bracket: PC, UL94V-0 Transparent ColourRJ45 Jack Contact: Material: Phosphor Bronze with Nickel Plated Finish: 50 micro-inch Gold plated on Plug Contact areaIDC: Housing: PC, UL94V-0 Terminal: Phosphor Bronze with Tin plated IDC CAP: PC, UL94V-0PCB: FR4, UL 94V-0

NKJ-5EWHI1B21NKJ-5EBLU1B21NKJ-5ERED1B21NKJ-5EGRN1B21NKJ-5EYEL1B21

Cat5e UTP Keystone Jack-WhiteCat5e UTP Keystone Jack-BlueCat5e UTP Keystone Jack-RedCat5e UTP Keystone Jack-GreenCat5e UTP Keystone Jack-Yellow

PART CODE DESCRIPTION

• RJ45 8P 8C 50u’ Jack• Terminating 4 pairs, 23-24 AWG cable• Universal labels Colour-coded for T568A and T568B wiring schemes • Fitting 1U 24 port High-Density Keystone panel

KEY FEATURES

Page 9: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 9

Cat5

e So

lutio

n Pr

oduc

ts

CAT5e UTP PATCH CORDS

D-Link CAT5e UTP Patch Cords are high-quality four-pair twistedstranded cables terminated with RJ45 modular plugs at boththe ends. It is as per the TIA/EIA-568-C.2 standard. These patch cords are appropriate for high speed data transmission.

• 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T (IEEE802.3)• 100VG-AnyLAN (IEEE802.12)• 500MHz Broadband Video• Voice,T1, ISDN • 155/622 Mbps ATM • Power over Ethernet (PoE)

APPLICATION

NCB-5EUGRYR1-05NCB-5EUBLUR1-1NCB-5EUBLUR1-2NCB-5EUBLUR1-3NCB-5EUGRYR1-5NCB-5EUGRYR1-10NCB-5EUGRYR1-15

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

MODULAR CONNECTOR / PLUG

Conductor: 24 AWG, Multi-strandsConductor Metal: Bare CopperInsulation Material: High Density PolyethyleneMaterial: PVC UL94V-0Heat Resistance: 60°C minimum (Temperature limited)Flame Property: The purpose of the vertical lame test is to screen out flammable wires. It follows the VW-1 (UL) and FT-1 (GA) standardsInsertion Cycles: 750 times

Cat5e UTP 24AWG Patch Cord, 0.5m, GreyCat5e UTP 24AWG Patch Cord, 1m, BlueCat5e UTP 24AWG Patch Cord, 2m, BlueCat5e UTP 24AWG Patch Cord, 3m, BlueCat5e UTP 24AWG Patch Cord, 5m, GreyCat5e UTP 24AWG Patch Cord, 10m, GreyCat5e UTP 24AWG Patch Cord, 15m, Grey

Material: Phosphor Bronze with Nickel PlatedFinish: 50 micro-inch Gold platedTemperature Range: -10 ~ 80°CDielectric withstanding voltage: 500V ACInsulation Resistance: 35M Ohm (max.)

RJ45 JACK CONTACT

DESCRIPTION

Page 10: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

10

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

CAT5e UTP LOADED PATCH PANELS

D-Link Category 5e patch panels are six port RJ45 modulesapplied and suitable for 22-26AWG stranded and solid wire,compatible with both 110 & Krone punch down tools. D-LinkCat5e patch panels have improved Cable Management withoptional Cable Management bar terminating 4 pairs UTPcable. They are complied with the TIA/EIA-568-C.2standard.

• Six-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with Krone tool• Terminating 4 pairs, 22-26 AWG, unshielded cable• Improved cable management with an optional cable management bar (Simple type, or "T" slot type)• Universal labels Colour-coded for T568A and T568B wiring schemes

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

I.D. Plate: PVC, Transparent Color PaperPanel: SPCC. 1.5 mm thickness with Black (RAL 9005) Colour paintedRJ45 Jack: Housing: ABS, UL94V-0 Contact Bracket: PC, UL 94V-2. Transparent ColourRJ45 Jack Contact: Material: Phosphor Bronze with Nickel plated Finish: 50 micro-inch Gold plated on Plug contact areaIDC: Housing: PC+Glass Fiber, UL 94V-2 Terminal: Phosphor Bronze with Tin plated Jack Bracket Set: ABS, UL 94V-0Support Bar: SPCC, 1.5 mm thickness with Black (RAL 9005) Colour painted

NPP-5E1BLK241NPP-5E1BLK481

Cat5e UTP 24 Port Loaded Patch PanelCat5e UTP 48 Port Loaded Patch Panel

PART CODE DESCRIPTION

Page 11: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 11

Cat5

e So

lutio

n Pr

oduc

ts

CAT5e FTP CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 100MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat5e specifications• 4-pair shielded twisted pair (FTP) cable• 24 AWG solid copper conductor for superior conductivity• PE insulation• FR PVC Jacket• Pairs are wrapped in aluminum foil with drain wire• Packaged in MDF spool in a box

KEY FEATURES

NCB-5ESGRYR-305-24

NCB-5ESBLUR-305

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Cat5e FTP 24 AWG PVC Solid Cable-305m/Roll,Grey ColourCat5e FTP 24 AWG PVC Solid Cable-305m/Roll,Blue Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100m Mutual Capacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Conductor: 24 AWG Solid bare Copper (4 pair) Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: FR PVCShield: Aluminum /Polyester FoilCable Diameter: 6.0 mm nominal

Foil ShieldPVC SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Drain Wire

Page 12: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

12

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 4x cable diameter at -20°C ± 1°CPulling Force: 9.5kgOperating Temperature Range: -20°C to +70°CStorage Temperature Range : 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 65.3 62.3 63.8 60.8 63.3 60.3

4 4.1 23.0 56.3 53.3 51.8 48.8 52.2 49.2

8 5.8 24.5 51.8 48.8 45.7 42.7 46.0 43.0

10 6.5 25.0 50.3 47.3 43.8 40.8 43.8 40.8

16 8.2 25.0 47.2 44.2 39.7 36.7 39.0 36.0

20 9.3 25.0 45.8 42.8 37.8 34.8 36.5 33.5

25 10.4 24.2 44.3 41.3 35.8 32.8 33.9 30.9

31.25 11.7 23.3 42.9 39.9 33.9 30.9 31.2 28.2

62.5 17.0 20.7 38.4 35.4 27.9 24.9 21.4 18.4

100 22.0 19.0 35.3 32.3 23.8 20.8 13.1 10.3

Available in MDF spool in a box of guaranteed 305m length

Page 13: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 13

Cat5

e So

lutio

n Pr

oduc

ts

CAT5e FTP OUTDOOR CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 100MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat5e specifications• 4-pair shielded twisted pair (FTP) cable• 24 AWG solid copper conductor for superior conductivity• PE insulation• UV PVC Outer Jacket• Pairs are wrapped in aluminum foil with drain wire• Packaged in MDF spool in a box

KEY FEATURES

NCB-5EFOBLR-305

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Cat5e FTP 24 AWG UV PVC Outdoor Cable-305m/Roll, Black Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Conductor: 24 AWG Solid bare Copper (4 pair) Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: UV PVC Outer sheathShield: Aluminum/Polyester FoilCable Diameter: 6.3 mm nominal

UV-Rated PVC SheathTinned Cu Drain WireRip CordCopper ConductorColoured InsulationInsulation with Colour StripeAluminum Foil Mylar

Page 14: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

14

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 4x cable diameter at -20°C ± 1°C Pulling Force: 9.5KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 65.3 62.3 63.8 60.8 63.3 60.3

4 4.1 23.0 56.3 53.3 51.8 48.8 52.2 49.2

8 5.8 24.5 51.8 48.8 45.7 42.7 46.0 43.0

10 6.5 25.0 50.3 47.3 43.8 40.8 43.8 40.8

16 8.2 25.0 47.2 44.2 39.7 36.7 39.0 36.0

20 9.3 25.0 45.8 42.8 37.8 34.8 36.5 33.5

25 10.4 24.2 44.3 41.3 35.8 32.8 33.9 30.9

31.25 11.7 23.3 42.9 39.9 33.9 30.9 31.2 28.8

62.5 17.0 20.7 38.4 35.4 27.9 24.9 21.4 18.4

100 22.0 19.0 35.3 32.3 23.8 20.8 13.3 10.3

Page 15: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 15

Cat5

e So

lutio

n Pr

oduc

ts

CAT5e SFTP CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard.Operates at bandwidth of 100MHz. Tinned Copper Screeninggives Protection against EMI and avoid signal loss. BetterMechanical Properties of Cable. This cable well exceeds therequirements of TIA/EIA-568.C.2

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat5e specifications• 4-pair screened foil twisted pair Cable• 24 AWG solid copper conductor• Pairs are wrapped in polyester tape and alumi num foil with drain wire• High Density Polyethylene Insulation• FR PVC Jacket• Tinned Copper braiding for mechanical strength• Packaged in MDF spools in a box

KEY FEATURES

SPECIFICATIONS

ELECTRICAL PROPERTIES

Conductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5%MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45ns

COLOUR CODE

1-23-64-57-8

NCB-5ESFGRR-305

PART CODE

ORDERING INFORMATION

CAT5e SFTP 24AWG Solid: 305m, Grey Colour

DESCRIPTION

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Category: Cat5e SFTP Solid cableConductor: 24 AWG Solid bare Copper (4 pair)Insulation: HD-PEShield: Aluminum / Polyester Foil Tinned Copper BraidingCable Diameter: 6.3mm nominal

SheathRip Cord

Copper ConductorColoured Insulation

Insulation with Colour Stripe

AL Foil Mylar

Tinned Copper Braiding

Page 16: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

16

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

www.dlinkmea.com

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 8x cable diameter at -20°C ± 1°C Pulling Force: 9.5KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS

(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 65.3 62.3 63.8 60.8 63.3 60.3

4 4.1 23.0 56.3 53.3 51.8 48.8 52.2 49.2

8 5.8 24.5 51.8 48.8 45.7 42.7 46.0 43.0

10 6.5 25.0 50.3 47.3 43.8 40.8 43.8 40.8

16 8.2 25.0 47.2 44.2 39.7 36.7 39.0 36.0

20 9.3 25.0 45.8 42.8 37.8 34.8 36.5 33.5

25 10.4 24.2 44.3 41.3 35.8 32.8 33.9 30.9

31.25 11.7 23.3 42.9 39.9 33.9 30.9 31.2 28.2

62.5 17.0 20.7 38.4 35.4 27.9 24.9 21.4 18.4

100 22.0 19.0 35.3 32.3 23.8 20.8 13.3 10.3

Page 17: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.comwww.dlinkmea.comwww.dlinkmea.com

Cat6

Sol

utio

n Pr

oduc

tsCa

t6a

Solu

tion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.com 17

Cat5

e So

lutio

n Pr

oduc

ts

CAT5e SHIELDED PATCH PANELS

D-Link Category 5e shielded patch panels are eight portRJ45 modules applied and suitable for 22-26AWG strandedand solid wire, compatible with Krone punch down tools. D-Link patch panels have improved Cable Management with optional Cable Management bar terminating 4 pairs UTP cable. They are complied with the ANSI/TIA/EIA-568-C.2 standard.

• Eight-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with Krone tool• Terminating 4 pairs, 22-26 AWG, shielded cable• Friendly installation, right angle between IDCs and RJ45 Keystone jacks• Jack shutter to keep dust away• Hand screw,easy to open cover

KEY FEATURES

SPECIFICATIONS

NPP-5E2BLK241NPP-5E2BLK481

PART CODE

ORDERING INFORMATION

Cat5e Shielded 24 Port Loaded Patch PanelCat5e Shielded 48 Port Loaded Patch Panel

DESCRIPTION

Identification: I.D. Plate: PVC. Transparent Colour PaperPanel: SPCC. 1.2 mm thickness with Black (RAL 9005) Colour paintedRJ45 Jack: Housing: PBT+15%GF, UL 94V-0.RJ45 Jack Contact: Material: Phosphor Bronze Finish: 3mm 50 micro-inch Gold plated over nickel platedIDC: Terminal: Phosphor Bronze with Tin platedDust Cover: PC, UL 94V-0, Transparent Black (RAL 9004) colourGround wire: 18AWG wire, with green/yellow striped colour, length 40cm

Page 18: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

18 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 UTP 23 AWG CABLE

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT)standard.Operates at bandwidth of 250MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat 6 specifications• 4-pair unshielded twisted pair (UTP) cable• 23 AWG solid copper conductor for superior conductivity• PE insulation• PE central cross• FR PVC /LSZH Jacket• Verified compliant with EIA/TIA standards by ETL & UL-listed• Packaged in an easy-to-pull reel in a box for easier installation

KEY FEATURES

NCB-C6UGRYR-100NCB-C6UBLUR-100NCB-C6UGRYR-305NCB-C6UGRNR-305NCB-C6UORGR-305NCB-C6UVLTR-305NCB-C6UGRYR-305-LS

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Conductor: 23 AWG Solid bare Copper (4 pair)Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: FR PVC/LSZHCable Diameter: 6.0 mm nominal

Cat6 UTP 23 AWG PVC Solid Cable-100m/Roll - Grey ColourCat6 UTP 23 AWG PVC Solid Cable-100m/Roll - Blue ColourCat6 UTP 23 AWG PVC Solid Cable-305m/Roll - Grey ColourCat6 UTP 23 AWG PVC Solid Cable-305m/Roll - Green ColourCat6 UTP 23 AWG PVC Solid Cable-305m/Roll - Orange ColourCat6 UTP 23 AWG PVC Solid Cable-305m/Roll - Violet ColourCat6 UTP 23 AWG LSZH Solid Cable-305m/Roll - Grey Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOURPVC SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Page 19: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 19

Cat6

a So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 4*Cable Diameter at -20°C ± 1°C Pulling Force: 11.5 KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2 and ISO/IEC 11801 Class E

Available in easy-pull reel in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.25 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 20: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

20 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 UTP 24 AWG CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat 6 specifications• 4-pair unshielded twisted pair (UTP) cable• 24 AWG solid copper conductor for superior conductivity• PE insulation• PE central cross• FR PVC Jacket• Packaged in an easy-to-pull reel in a box for easier installation

KEY FEATURES

NCB-C6UGRYR-305-24

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Conductor: 24 AWG Solid bare Copper (4 pair)Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: FR PVCCable Diameter: 5.8 mm nominal

Cat6 UTP 24 AWG PVC Solid Cable-305m/Roll- Grey Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100m MutualCapacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

PVC SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Page 21: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 21

Cat6

a So

lutio

n Pr

oduc

ts

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100m MutualCapacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 25.4mm at -20°C ± 1°CPulling Force: 11.5 KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801 Class E

Available in easy-pull reel in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 22: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

22 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 UTP KEYSTONES

D-Link Category 6 keystone jacks are RJ45 8P 8C 50u jacks suitable for 22-26 AWG stranded and solid wire, compatible with both 110 & Krone punch down tools. They are available in universal labels Colour coded for T568A and T568B wiring schemes and fit in high density keystone patch panel. It supports IEC 60603-7-4 and complied with ANSI/TIA/ EIA-568-C.2 standard.

• RJ45 8P 8C 50u" Jack• Terminating 4 pairs, 22-26 AWG cable• Universal labels Colour-coded for T568A and T568B wiring schemes • Fitting 1U 24 port High-Density Keystone panel• 3P/ETL verified unshielded EIA/TIA/ connecting hardware

KEY FEATURES

NKJ-C6WHI1B21NKJ-C6BLU1B21NKJ-C6RED1B21NKJ-C6GRN1B21NKJ-C6YEL1B21

PART CODE

ORDERING INFORMATION

Cat6 UTP Keystone Jack, WhiteCat6 UTP Keystone Jack, BlueCat6 UTP Keystone Jack, RedCat6 UTP Keystone Jack, GreenCat6 UTP Keystone Jack, Yellow

DESCRIPTION

SPECIFICATIONS

RJ45 Jack: Housing: PC, UL94V-0 with Option Color Contact Bracket: PC, UL94V-0 Transparent ColourRJ45 Jack Contact: Material: Phosphor Bronze with Nickel Plated Finish: 50 micro-inch Gold plated on Plug Contact areaIDC: Housing: PC,UL94V-0 Terminal: Phosphor Bronze with Tin plated IDC CAP: PC, UL94V-0

Page 23: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 23

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 UTP PATCH CORDS

D-Link Cat6 patch cords are high-quality four pair twistedstranded cable terminated with RJ45 modular plugs at boththe ends. It complies to the TIA/EIA-568-C.2 standard. These patch cords are appropriate for high-speed data transmissions.

• 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T• 100VG-AnyLAN (IEEE802.12)• 500MHz Broadband Video• Voice, T1, ISDN• 155/622 Mbps ATM• Power over Ethernet (PoE)

APPLICATION

NCB-C6UGRYR1-05NCB-C6UGRYR1-1NCB-C6UGRYR1-2NCB-C6UGRYR1-3NCB-C6UGRYR1-5NCB-C6UGRYR1-10NCB-C6UGRYR1-15

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

MODULAR CONNECTOR / PLUGConductor: 24 AWG Multi-strandsConductor Metal: Bare CopperInsulation: High Density PolyethyleneMaterial: PVC Heat Resistance: 60°C minimum (Temperature Limited) Flame Property: The purpose of the vertical flame test is to screen out flammable wires. It follows the VW-1(UL)and FT-1 (CSA) InsertionCycles: 750 times

Cat6 UTP 24AWG Patch Cord, 0.5mCat6 UTP 24AWG Patch Cord, 1mCat6 UTP 24AWG Patch Cord, 2mCat6 UTP 24AWG Patch Cord, 3mCat6 UTP 24AWG Patch Cord, 5mCat6 UTP 24AWG Patch Cord, 10mCat6 UTP 24AWG Patch Cord, 15m

Material: Copper Alloy with Nickel PlatedFinish: 50 micro-inch Gold platedTemperature Range: -40° ~ 125°CDielectric withstanding voltage: 1000V DC/min, <0.5AInsulation Resistance: >500M Ohm, 1000V DC/min

RJ45 JACK CONTACT

DESCRIPTION

*1, 2 and 3 meters are also available in red, blue, green and yellow colours

*0.5 meters are also available in blue and yellow colours

Page 24: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

24 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 UTP PATCH PANELS

D-Link Category 6 patch panels are six port RJ45 modulesapplied and suitable for 22-26AWG stranded and solid wire, compatible with both 110 & Krone punch down tools. D-Link patch panels have improved Cable Management with optional Cable Management bar terminating 4 pairs UTP cable. They are complied with the ANSI/TIA/EIA-568-C.2 standard.

• Six-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with 110 & Krone tool• Terminating 4 pairs, 22-26 AWG, unshielded cable• Improved cable management with an optional cable management bar (Simple type, or "T" slot type)• Universal labels Colour-coded for T568A and T568B wiring schemes

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

Identification: I.D. Plate: PC, Transparent color with paperPanel: SPCC. 1.6 mm thickness with Black (RAL 9005) Colour paintedRJ45 Jack: Housing: PBT+ Glass Fiber UL94V-0 Contact Bracket: PBT+Glass Fiber, UL94V-0, Black Color RJ45 Jack Contact: Material: Phosphor Bronze with Nickel plated Finish: 50 micro-inch Gold plated on Plug contact areaIDC: Housing: PC, UL94V-0 Terminal: Phosphor Bronze with Tin platedJack Bracket Set: ABSSupport Bar: SPCC, 1.6 mm thickness with Black (RAL 9005) Colour painted

NPP-C61BLK241NPP-C61BLK481

Cat6 UTP 24 Port Loaded Patch PanelCat6 UTP 48 Port Loaded Patch Panel

PART CODE DESCRIPTION

Page 25: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 25

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 0.5U LOADED PATCH PANELS

D-Link Category 6 0.5U patch panels are eight port RJ45modules applied and suitable for 22-26AWG stranded andsolid wire, compatible with both 110 & Krone punch downtools. D-Link patch panels have improved CableManagement with optional Cable Management barterminating 4 pairs UTP cable. They are complied with theANSI/TIA/EIA-568-C.2 standard.

• Eight-port RJ45 modules applied• High Density 24 port 0.5U patch panel• IDC compatible with 110 & Krone tool• Terminating 4 pairs, 22-26 AWG, stranded and solid wire• Ideal for limited rack space solutions

KEY FEATURES

Panel:RJ45 Jack: RJ45 Jack Contact:

IDC: Dust Cover:

SPCC. 1.5 mm thickness with Black (RAL 9005) Colour paintedHousing: PBT+GF,UL 94V-0, Contact brackets: PBT+GF,UL94V-2Material: Phosphor Bronze with nickel plating Finish: 50 micro-inch Gold plated on plug contact areaHousing:PC+GF,UL94V-2, Terminal: Phosphor Bronze with Tin platedPC, UL 94V-0

SPECIFICATIONS

NPP-C61BLK243

PART CODE

ORDERING INFORMATION

Cat6 Unshielded 24 Port Loaded Patch Panel-0.5U

DESCRIPTION

Page 26: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

26 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 LOADED ANGLED PATCH PANELS

D-Link Category 6 angled patch panels are six port RJ45modules applied and suitable for 22-26AWG stranded andsolid wire, compatible with both 110 & Krone punch downtools. D-Link patch panels have improved CableManagement with optional Cable Management barterminating 4 pairs UTP cable. They are complied with theANSI/TIA/EIA-568-C.2 standard.

• Six-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with 110 & Krone tool• Terminating 4 pairs, 22-26 AWG, stranded and solid wire• Designed to easily route cables into vertical cable managers• Reduces the need for horizontal, front cable management bars

KEY FEATURES

SPECIFICATIONS

Identification: Panel: RJ45 Jack: RJ45 Jack Contact:

IDC: Back Cover: Support wire:

I.D. Plate: PVC. Transparent Colour PaperSPCC. 1.5 mm thickness with Black Colour paintedHousing: PBT + GF,UL 94V-0.Material: Phosphor Bronze with Nickel plated Finish: 50 micro-inch Gold plated over nickel platedHousing: PC +GF,UL 94 V-2,Terminal: Phosphor Bronze with Tin platedABS, UL 94V-0SPCC,1.5mm thickness,painted in black

NPP-C61BLK242

PART CODE

ORDERING INFORMATION

Cat6 Unshielded Angled 24 Port Loaded Patch Panel

DESCRIPTION

Page 27: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 27

Cat6

a So

lutio

n Pr

oduc

ts

I.D. Plate: PVC. Transparent Colour PaperSPCC. 1.5 mm thickness with Black Colour paintedHousing: PBT + GF,UL 94V-0.Material: Phosphor Bronze with Nickel plated Finish: 50 micro-inch Gold plated over nickel platedHousing: PC +GF,UL 94 V-2,Terminal: Phosphor Bronze with Tin platedABS, UL 94V-0SPCC,1.5mm thickness,painted in black

CAT6 FTP 23 AWG CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250MHz. The shield acts as a Faraday cage to reduce electrical noise from affecting the signals, and to reduceelectromagnetic radiation that may interfere with other devices.This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801.

• Comply with Cat 6 specifications• 4-pair shielded twisted pair (FTP) cable• 23 AWG solid copper conductor for superior conductivity• PE insulation• PE central cross• FR PVC Jacket• Packaged in MDF spool in a box

KEY FEATURES

NCB-C6SGRYR-305

NCB-C6SGRYR-305-LS

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Conductor: 23 AWG Solid bare Copper (4 pair)Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: FR PVC/LSZHShield: Aluminum /Polyester FoilCable Diameter: 7.0 mm nominal

Cat6 FTP 23 AWG PVC Solid Cable -305m/Roll-Grey Colour

Cat6 FTP 23 AWG LSZH Solid Cable -305m/Roll-Grey Colour

Characteristic Impedance: 100± 15ΩConductor Resistance: ≤ 9.38Ω/100m Mutual Capacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Foil ShieldPVC/LSZH SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Drain Wire

Page 28: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

28 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 8*Cable Diameter at -20°C ± 1°C Pulling Force: 11.5 KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801 Class E

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 29: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 29

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 FTP 24 AWG CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250MHz. The shield acts as a Faraday cage to reduce electrical noise from affecting the signals, and to reduce electromagnetic radiation that may interfere `with other devices. This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801.

• Comply with Cat 6 specifications• 4-pair shielded twisted pair (FTP) cable• 24 AWG solid copper conductor for superior conductivity• PE insulation• PE central cross• FR PVC Jacket• Pairs are wrapped in aluminum foil with drain wire• Packaged in MDF spool in a box

KEY FEATURES

NCB-C6SGRYR-305-24

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Conductor: 24 AWG Solid bare Copper (4 pair) Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: FR PVCShield: Aluminum /Polyester FoilCable Diameter: 6.8 mm nominal

Cat6 FTP 24 AWG PVC Solid Cable-305m/Roll - Grey Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100m MutualCapacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP: 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Foil ShieldPVC SheathRip CordCopper ConductorColoured Insulation

Insulation with Colour Stripe

Drain Wire

Page 30: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

30 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: 8*Cable Diameter at -20°C ± 1°CPulling Force: 11.5 KgOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801 Class E

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 31: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 31

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 FTP DOUBLE SHEATH OUTDOOR CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250MHz. The shield acts as a Faraday cage to reduce electrical noise from affecting the signals, and to reduce electromagnetic radiation that may interfere with other devices. This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801.

• Comply with Cat 6 specifications• 4-pair shielded twisted pair (FTP) cable• 23 AWG solid copper conductor for superior conductivity• PE insulation• PE central cross• Double layer PVC/UV PVC Outer Jacket• Pairs are wrapped in aluminum foil with drain wire• Packaged in MDF spool in a box

KEY FEATURES

NCB-C6FOBLR-305

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Conductor: 23 AWG Solid bare Copper (4 pair)Insulation: High Density PolyethylenePairs: 2 Insulated conductors twisted togetherSheath: Double Sheath, (PVC Inner Sheath, UV PVC, Outer Sheath)Shield: Aluminum/Polyester FoilCable Diameter: 8.3 mm nominal

Cat6 FTP 23 AWG PVC/UV PVC Outdoor Cable-305m/Roll, Black Colour

Characteristic Impedance: 100±15ΩConductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45nsNVP 69%

DESCRIPTION

COLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

Outer Sheath - UV PVCInner Sheath PVCRip CordCopper ConductorColoured InsulationInsulation with Colour StripeSeparatorAluminum / Polyester FoilDrain Wire

Page 32: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

32 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: > 10 x Cable Diameter at -20°C ± 1°CPulling Force: 11.5 KgsOperating Temperature Range: -20°C to +70°CStorage Temperature Range: 0°C to +50°C

Compatible with all common systems according to TIA/EIA 568-C.2and ISO/IEC 11801 Class E

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 33: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 33

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 SFTP CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (1000 baseT) standard.Operates at bandwidth of 250MHz. Tinned Copper Screeninggives Protection against EMI and avoid signal loss. BetterMechanical Properties of Cable. This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801

• Comply with Cat6 specifications• 4-pair screened foil twisted pair Cable• 23 AWG solid copper conductor• Pairs are wrapped in polyester tape and aluminum foil with drain wire• High Density Polyethylene Insulation• FR PVC Jacket• Tinned Copper braiding for mechanical strength• Packaged in MDF spools in a box

KEY FEATURES

NCB-C6SFGRR-305

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

ELECTRICAL PROPERTIES

Category: Cat6 SFTP Solid cableConductor: 23 AWG Solid bare Copper (4 pair)Conductor: Bare CopperInsulation: HD-PEShield: Aluminum / Polyester Foil Tinned Copper BraidingCable Diameter: 7.6 mm nominal

CAT6 SFTP 23AWG Solid: 305m,Grey Color

Conductor Resistance: ≤ 9.38 Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5%MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45ns

DESCRIPTIONCOLOUR CODE

1-23-64-57-8

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

PAIR NO. COLOUR

SheathRip Cord

Copper ConductorColoured Insulation

Insulation with Colour StripeAL Foil Mylar

Tinned Copper Braiding

Page 34: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

34 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

MECHANICAL PROPERTIES

CONNECTION SYSTEM

PACKING

Bending Radius: < 8 x Cable Diameter at -20°C ± 1°CPulling Force: 11.5KgsTemperature Range: -20°to +70°C

Compatible with all common systems according to TIA/EIA 568-C.2

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

INSERTION LOSS(dB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ELFEXT(dB)

PSELFEXT(dB)

ACR(dB)

PSACR(dB)

1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3

4 3.8 23.0 65.6 63.3 55.8 52.8 61.5 59.5

8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5

10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3

16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6

20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3

25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8

31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2

62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0

100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5

200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8

250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Page 35: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 35

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 FTP KEYSTONE JACKS

D-Link Category 6 keystone jacks are RJ45 8P 8C 50u jackssuitable for 22-26 AWG stranded and solid wire, compatiblewith both 110 & Krone punch down tool. They are capable ofre-termination. They are available in universal labels Colourcoded for T568A and T568B wiring schemes and fit in highdensity keystonepatch panel. It supports IEC 60603-7- 4 andcomplied with ANSI/TIA/EIA-568-C.2 standard.

Contact Resistance: 100 milliohms

• RJ45 8P 8C 180º 50u Punch Down Jack• Terminating 4 Pairs, 22-26 AWG Cable, stranded and solid wire• Universal labels colour-coded for T568A and T568B wiring schemes• Fitting high density keystone panel

KEY FEATURES

NKJ-C6SMET2B21

PART CODE

ORDERING INFORMATION

Cat6 FTP 180° Tool Less Keystone Jack-Metallic

DESCRIPTION

SPECIFICATIONS

RJ45 Jack Shield: Zinc AlloyRJ45 Jack: Housing: Zinc Alloy Contact Bracket: PC, UL 94V-2 Transparent ColourRJ45 Jack Contact: Material: Phosphor Bronze with Nickel Plated Finish: 50 micro-inch Gold plated on Plug Contact areaIDC: Housing: PC, UL94V-2 Terminal: Phosphor Bronze with Tin platedIDC CAP: Zinc Die-Casting, Nickel-Plated

Page 36: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

36 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 STP PATCH CORDS

D-Link Cat6 STP patch cords are high quality four pair shielded twisted stranded cable terminated with RJ45 modular plugs at both the ends. It is TIA/EIA 568C.2 stan-dard. The shielded cables helps to complete a proper ground connection and allows longer runs with less effect of Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). These patch cords are appropriate for high speed data transmission.

• 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T,• 100VG-AnyLAN (IEEE802.12)• 500MHz Broadband Video• Voice, T1, ISDN 155/622 Mbps ATM• Power over Ethernet (PoE)

APPLICATION

NCB-C6SGRYR1-1NCB-C6SGRYR1-2NCB-C6SGRYR1-3

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

MODULAR CONNECTOR / PLUG

Conductor: 26 AWG Multi-strandsConductor Metal: Bare CopperInsulation Material: High Density PolyethyleneDrain Wire: 28 AWGMaterial: PVCColour Code: GreyHeat Resistance: 60°C minimum (Temperature Limited)Flame Property: The purpose of the vertical flame test is to screen out flammable wires. It follows the VW-1(UL) and FT-1 (CSA).

Cat6 STP 26AWG Patch Cord, 1mCat6 STP 26AWG Patch Cord, 2mCat6 STP 26AWG Patch Cord, 3m

Material: Copper Alloy with Nickel PlatedFinish: 50 micro-inch Gold platedTemperature Range: -40° ~ 125°CDielectric withstanding voltage: 1000V DC/min, <0.5AInsulation Resistance: >500M Ohm, 1000V DC/min

RJ45 JACK CONTACT

DESCRIPTION

Page 37: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 37

Cat6

a So

lutio

n Pr

oduc

ts

CAT6 SHIELDED PATCH PANELS

D-Link Category 6 Shielded patch panels are eight ports RJ-45modules applied and suitable for 22-26 AWG stranded andsolid wire, compatible with Krone punch down tools. D-Link patch panels terminate 4 pairs STP cable and are rack mounted. They are complied with the ANSI/TIA/EIA 568C.2-1 standard

• Hand screw, easy to open cover• Eight port RJ45 modules applied• Jack shutter to keep dust away• Friendly installation, right angle between IDCs and RJ45 jacks• ID stripes for identifying port allocations• IDC: suitable for 22-26 AWG stranded and solid wire, compatible with Krone punch down tools

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

Identification: ID plate PVC, transparent Colour with paper ID Bracket: ABS + PC, UL 94V-0 Panel: SECC, 1.2mm thickness with optional Colour paintedRJ45 Jack: Housing: PBT + Glass fiber, UL-94V-0 Contact Brackets: PBT + Glass fiber, UL-94V-0RJ45 Jack Contact: Material: Phosphor bronze with nickel plated Black (RAL 9005) Colour painted Finish: 50 micro-inches Gold plated on plug contact area RJ45 Jack Shield: Bronze with nickel platedDust Cover: PC, UL94V-2IDC: Housing: PC+ glass fiber, UL 94V-2 Terminal: Phosphor bronze with tin plated Ground Wire: 18 AWG wire with Green/Yellow Striped colour

NPP-C62BLK241NPP-C62BLK481

Cat6 24 Port Shielded Loaded Patch PanelCat6 48 Port Shielded Loaded Patch Panel

PART CODE DESCRIPTION

Page 38: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

38 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a UTP CABLES

Enhanced performance cable for transmission of high speeddata, digital and analogue voice and video (RGB) signals onLANs. Supports Gigabit Ethernet (10GbaseT)standard.Operates at bandwidth of 500MHz.

This cable well exceeds the requirements of TIA/EIA-568-C.2 Category 6A ISO 11801-2 cot Class E. Exceeds all requirements for IEE 802.3at.

• Comply with Cat 6a specifications• 4-pair unshielded twisted pair (UTP) cable• 23 AWG solid copper conductor with a frequency of 500 MHZ • HD-PE insulation, PE central cross• FR PVC Jacket• Packaged in MDF spool in a box

KEY FEATURES

NCB-6AUGRYR-305

1 -23-64-57-8

PART CODE

PAIR NO.

ORDERING INFORMATION

COLOUR CODE

CAT6A UTP 23AWG Solid: 305m/Roll,Grey Colour

White/Orange Stripe and Orange White/Green Stripe and GreenWhite/Blue Stripe and Blue White/Brown Stripe and Brown

DESCRIPTION

COLOUR

SPECIFICATIONS

ELECTRICAL PROPERTIES

Category: 6a UTP Solid cableConductor: 23 AWG (Solid)Conductor Metal: Bare CopperInsulation Material: High Density PolyethyleneSheath: FR PVCCable Diameter: 8.0mm Nominal

Conductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: <5.6nF/100mResistance Unbalance: 5%MaxDelay Skew: < 45nsNVP%: 68.2

PVC SheathRip Cord

ColouredInsulationCopper ConductorInsulation with StripeSeparator

Page 39: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 39

Cat6

a So

lutio

n Pr

oduc

ts

CONNECTION SYSTEM

PACKING

Compatible with all common systems according to TIA/EIA 568-C.2 and ISO / IEC 11801 Class E

Available in MDF spool in a box of guaranteed 305m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

MAX ATTENUATION

(DB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ACR(dB)

PSACRF(dB)

1 2.1 20.0 74.3 72.3 67.8 64.8

4 3.8 23.0 65.3 63.3 55.8 52.8

10 5.9 25.0 59.3 57.3 47.8 44.8

16 7.5 25.0 56.2 54.2 43.7 40.7

20 8.4 25.0 54.8 52.8 41.8 38.8

31.25 10.5 23.6 51.9 49.9 37.9 34.9

62.5 15 21.5 47.4 45.4 31.9 28.9

100 19.1 20.1 44.3 42.3 27.8 24.8

200 27.6 18.0 39.8 37.8 21.8 18.8

250 31.1 17.3 38.3 36.3 19.8 16.8

300 34.3 16.8 38.1 35.1 18.3 15.3

500 45.3 15.2 34.8 31.8 13.8 10.8

Page 40: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

40 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

• RJ45 8P 8C 50u, dual function:tool-free & punch down• Terminating 4 Pairs, 23-26 AWG stranded and solid Cables• Universal labels colour-coded for T568A and T56 8B wiring schemes• Compatible with both 110 & Krone punch down tools• Tool-less when using the IDC Cap for wire management• Fitting high density keystone panel

KEY FEATURES

SPECIFICATIONS

D-Link Category 6a keystone jacks are RJ45 8P 8C 50u jacks suitable for 22-26 AWG stranded and solid wire, compatible with both 110 & Krone punch down tools. They are available in universal labels Colour coded for T568A and T568B wiring schemes and fit in high density keystone patch panel. It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard.

ORDERING INFORMATION

NKJ-6AWHI1B21NKJ-6ABLU1B21NKJ-6ARED1B21NKJ-6AGRN1B21NKJ-6ABLK1B21

Cat6a 10G UTP Keystone JackCat6a 10G UTP Keystone JackCat6a 10G UTP Keystone JackCat6a 10G UTP Keystone JackCat6a 10G UTP Keystone Jack

WhiteBlueRedGreenBlack

PART CODE DESCRIPTION COLOUR CODE

CAT6a UTP KEYSTONE JACKS

RJ45 Jack: Housing: ABS+PC, UL 94V-0, Black Colour Contact Bracket: PC, UL 94V-2, transparent ColourRJ45 Jack Contact: Material: phosphor bronze with nickel plated Finish: 50 micro-inch gold plated on plug contact areaIDC: Housing: PC + glass fiber, UL 94V-2 Terminal: Phosphor bronze with tin platedIDC CAP: PC + glass fiber, UL 94-V2, white Colour

Page 41: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 41

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a UTP PATCH CORDS

D-Link Cat6a patch cords are high quality four pair twistedstranded cable terminated with RJ45 modular plugs at boththe ends. It is TIA/EIA-568-C.2 standard.These patch cords are appropriate for high speed data transmission.

• 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T, 10GBASE-T (IEEE802.3)• 100VG-AnyLAN (IEEE802.12)• 500MHz Broadband Video• Voice, T1, ISDN• 155/622 Mbps ATM• Power over Ethernet (PoE)

APPLICATION

NCB-6AUGRYR1-1NCB-6AUGRYR1-2NCB-6AUGRYR1-3

PART CODE

SPECIFICATIONS

ORDERING INFORMATION

MODULAR CONNECTOR / PLUG

Conductor: 24 AWG Multi-strandsConductor: Bare CopperInsulation: HD-PEMaterial: PVCColour Code: GreyHeat Resistance: 60°C minimum (Temperature limited)Flame Property: The purpose of the vertical flame test is to screen out flammable wires. It follows the VW-1 (UL) and FT-1 (CSA) standardsCycles: 750 times

Cat6a UTP 24AWG Patch Cord, 1m, GreyCat6a UTP 24AWG Patch Cord, 2m, GreyCat6a UTP 24AWG Patch Cord, 3m, Grey

Material: Copper Alloy with Nickel PlatedFinish: 50 micro-inch Gold platedTemperature Range: -40° ~ 125°CDielectric withstanding voltage: 1000V DC/min, <0.5AInsulation Resistance: >500M Ohm, 1000V DC/min

RJ45 JACK CONTACT

DESCRIPTION

Page 42: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

42 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a UTP PATCH PANELS

D-Link Category 6A patch panels are eight port RJ45modules applied and suitable for 22-26AWG stranded and solid wire, compatible with both 110 & Krone punch down tools. D-Link patch panels have improved Cable Management with optional Cable Management bar terminating 4 pairs UTP cable. They are complied with the ANSI/TIA/EIA-568-C.2 standard.

• Eight-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with 110 & Krone tool• Terminating 4 pairs, 22-26 AWG, unshielded cable• Improved cable management with an optional cable management bar (Simple type, or "r slot type)• Universal labels Colour-coded for T568A and T568B wiring schemes

KEY FEATURES

SPECIFICATIONS

Identification:Panel:RJ45 Jack:RJ45 Jack Contact:

IDC:Jack Bracket Set:Support Bar:

Silk Printing in White Color on Black PanelSPCC. 1.6 mm thickness with Black (RAL 9005) Colour paintedHousing: PBT+ Glass Fiber UL94V-0; Contact Bracket: PBT+Glass Fiber, UL94V-0, BlackMaterial: Phosphor Bronze with Nickel plated Finish: 50 micro-inch Gold plated on Plug contact areaHousing: PC, Terminal: Phosphor Bronze with Tin platedABSSPCC, 1.6 mm thickness with Black (RAL 9005) Colour painted

NPP-6A1BLK242NPP-6A1BLK481

PART CODE

ORDERING INFORMATION

Cat6a UTP 24 Port Loaded Patch PanelCat6a UTP 48 Port Loaded Patch Panel

DESCRIPTION

Page 43: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 43

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a SHIELDED CABLES

KEY FEATURES

NCB-6ASGRYR-500-LS

1-23-64-57-8

PART CODE

PAIR NO.

ORDERING INFORMATION

COLOUR CODE

Cat6a 10G U/FTP 23AWG LSZH Solid Cable-500M/Roll - Grey Colour

White/Orange Stripe and OrangeWhite/Green Stripe and GreenWhite/Blue Stripe and BlueWhite/Brown Stripe and Brown

DESCRIPTION

COLOUR

SPECIFICATION

ELECTRICAL PROPERTIES

Enhanced performance cable for transmission of high speed data, digital and analogue voice and video (RGB) signals on LANs. It supports Gigabit Ethernet (10GbaseT) standard and operates at bandwidth of 500MHz. This cable well exceeds the requirements of ANSI/TIA-568-C.2. The shield acts as a Faraday cage to reduce electrical noise from affecting the signals, and to reduce electromagnetic radiation that may interfere with other devices.

Conductor Resistance: ≤ 9.38Ω/100mMutual Capacitance: < 5.6nF/100mResistance Unbalance: 5% MaxCapacitance Unbalance: 330pF/100mDelay Skew: < 45ns

• Comply with Cat6a specifications• 4-pair shielded twisted pair cable• 23 AWG solid copper conductor• Pairs are wrapped in polyester tape and aluminum foil with drain wire • High Density Polyethylene Insulation• FR PVC Jacket• Verified compliant with EIA/TIA standards • Packaged in MDF spool in a box for easier installation

LSZH Sheath

ColouredInsulationDrain Wire

Copper Conductor

Aluminium Foil

Conductor: 23 AWG Solid bare Copper (4 pair)Insulation: Foam Skin PEPairs: 2 Insulated conductors twisted together Sheath: LSZHIndividual Pair Shield Aluminum/Polyester FoilShield: Tinned Copper drain wireCable Diameter: 7.6 mm nominal

Page 44: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

44 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CONNECTION SYSTEM

PACKING

Compatible with all common systems according to ANSI/TIA-568-C.2

Available in MDF spool of guaranteed 500m length

TRANSMISSION CHARACTERISTICS PER 100M

FREQUENCYMHZ

MAX ATTENUATION

(DB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ACR(dB)

PSACRF(dB)

1 2.1 20.0 74.3 72.3 67.8 64.8

4 3.8 23.0 65.3 63.3 55.8 52.8

10 5.9 25.0 59.3 57.3 47.8 44.8

16 7.5 25.0 56.2 54.2 43.7 40.7

20 8.4 25.0 54.8 52.8 41.8 38.8

31.25 10.5 23.6 51.9 49.9 37.9 34.9

62.5 15 21.5 47.4 45.4 31.9 28.9

100 19.1 20.1 44.3 42.3 27.8 24.8

200 27.6 18.0 39.8 37.8 21.8 18.8

250 31.1 17.3 38.3 36.3 19.8 16.8

300 34.3 16.8 38.1 353.1 18.3 15.3

500 45.3 15.2 34.8 31.8 13.8 10.8

Page 45: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 45

Cat6

a So

lutio

n Pr

oduc

ts

FREQUENCYMHZ

MAX ATTENUATION

(DB/100M)

RL(dB)

NEXT(dB)

PSNEXT(dB)

ACR(dB)

PSACRF(dB)

1 2.1 20.0 74.3 72.3 67.8 64.8

4 3.8 23.0 65.3 63.3 55.8 52.8

10 5.9 25.0 59.3 57.3 47.8 44.8

16 7.5 25.0 56.2 54.2 43.7 40.7

20 8.4 25.0 54.8 52.8 41.8 38.8

31.25 10.5 23.6 51.9 49.9 37.9 34.9

62.5 15 21.5 47.4 45.4 31.9 28.9

100 19.1 20.1 44.3 42.3 27.8 24.8

200 27.6 18.0 39.8 37.8 21.8 18.8

250 31.1 17.3 38.3 36.3 19.8 16.8

300 34.3 16.8 38.1 353.1 18.3 15.3

500 45.3 15.2 34.8 31.8 13.8 10.8

CAT6a FTP KEYSTONE JACKS

D-Link Category 6A FTP keystone jacks are RJ45 8P 8C 50u Jacks suitable for 22-24 AWG stranded and solid wire, compatible with both 110 & Krone punch down tools. They fit in high density keystone patch panel. Compliant with TIA/EIA 568A and B.

KEY FEATURES

SPECIFICATIONS

NKJ-6ASMET2B21

PART CODE

ORDERING INFORMATION

Cat6a FTP 180° Tool-Less Keystone Jack-Metallic

DESCRIPTION

• RJ45 8P 8C 180º 50u Punch Down Jack• Terminating 4 Pairs, 22-26 AWG Cable, stranded and solid wire• Universal labels colour-coded for T568A and T568B wiring schemes• Fitting high density keystone panel

RJ45 Jack Shield: Zinc AlloyRJ45 Jack: Housing: Zinc Alloy Contact Bracket: PC, UL 94V-2 Transparent Co lourRJ45 Jack Contact: Material: Phosphor Bronze with Nickel Plated Finish: 50 micro-inch Gold plated on Plug Contact areaIDC: Housing: PC, UL94V-2 Terminal: Phosphor Bronze with Tin platedIDC CAP: Zinc Die-Casting, Nickel-Plated

Page 46: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s

46 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a SHIELDED PATCH CORDS

D-Link Cat6a shielded patch cords are high quality four pair twisted stranded cable terminated with RJ45 modular plugs at both the ends. It is compliant to the TIA/EIA 568C.2 standard. These patch cords are appropriate for high speed data transmission.

• 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T, 10GBASE-T (IEEE802.3)• 100VG-AnyLAN (IEEE802.12)• 500MHz Broadband Video• Voice, T1, ISDN• 155/622 Mbps ATM• Power over Ethernet (PoE)

ORDERING INFORMATION

APPLICATION

SPECIFICATIONS

Conductor: 26 AWG, Multi-coresConductor Metal: Bare CopperInsulation Material: HD-PEMaterial: PVCColour Code: GreyHeat Resistance: 60°C minimum (Temperature limited)

NCB-6ASGRYR1-1NCB-6ASGRYR1-2NCB-6ASGRYR1-3

Cat6a Shielded 26AWG Patch Cord, 1m, GreyCat6a Shielded 26AWG Patch Cord, 2m, GreyCat6a Shielded 26AWG Patch Cord, 3m, Grey

PART CODE DESCRIPTION

MODULAR CONNECTOR / PLUG

Gold Plated: 50U"Contact Blade Copper AlloyDielectric withstanding voltage: 1000V DC/min, <0.5AInsulation Resistance: >500M Ohm, 1000V DC/minUL Applications: UL94-V-2

RJ-45 8P FOR TRANSPARENT COLOUR

Page 47: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

ts

www.dlinkmea.comwww.dlinkmea.com 47

Cat6

a So

lutio

n Pr

oduc

ts

CAT6a SHIELDED PATCH PANELS

D-Link Category 6A shielded patch panels are eight portRJ45 modules applied and suitable for 22-26AWG strandedand solid wire, compatible with Krone punch down tools. D-Link patch panels have improved Cable Management with optional Cable Management bar terminating 4 pairs UTP cable. They are complied with the ANSI/TIA/EIA-568-C.2 standard.

• Eight-port RJ45 modules applied• ID stripes for identifying port allocations• IDC compatible with Krone tool• Terminating 4 pairs, 22-26 AWG, shielded cable• Friendly installation,right angle between IDCs and RJ45 Keystone jacks • Jack shutter to keep dust away• Hand screw,easy to open cover

KEY FEATURES

SPECIFICATIONS

Identification:Panel:RJ45 Jack:RJ45 Jack Contact: IDC:Dust Cover:Ground wire:

I.D. Plate: PVC. Transparent Colour PaperSECC. 1.2 mm thickness with Black (RAL 9005) Colour paintedHousing: PBT+GF,UL 94V-0.Material: Phosphor Bronze with nickel plating, Finish: 50 micro-inch Gold plated on plug contact areaHousing: PC+GF,UL94V-2,Terminal: Phosphor Bronze with Tin platedPC, UL 94V-218AWG wire, with green/yellow striped colour, length 40cm

NPP-6A2BLK241NPP-6A2BLK481

PART CODE

ORDERING INFORMATION

Cat6aShielded 24 Port Loaded Patch PanelCat6a Shielded 48 Port Loaded Patch Panel

DESCRIPTION

Page 48: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

48 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

UNLOADED PATCH PANELS

D-Link Unloaded Patch Panel 24/48 port RJ45 modulesapplied and suitable for Cat 5e, Cat 6 and Cat 6A. D-Link patch panel have improved cable management with optional cable management bar terminating 4 pairs UTP cable.

• With cable management bar for improved management • Staggered 24 port panel in 1U• Mounts in standard 19 inch racks• Feasible solution for lower interference and eliminate alien crosstalk

KEY FEATURES

SPECIFICATIONS

Cat6a Unloaded PanelPanel: PC + glass fiber, UL 94V-0, black ColourSupport Bar: PC + glass fiber, UL 94V-0, black Colour

Cat5e/Cat6 Unloaded Panel Support Bar: SPCC, 1.5 mm thickness with black colour paintedPanel: SPCC 1.5 mm thickness with black colour paintedInsert: ABS, UL 94V-0

Available in 1U and 2U patch panel

NPP-AL1BLK241NPP-AL1BLK481NPP-6A1BLK241

PART CODE

ORDERING INFORMATION

24-Port Unloaded Patch Panel for UTP Cat5e/Cat6 Keystone Jacks48-Port Unloaded Patch Panel for UTP Cat5e/Cat6 Keystone Jacks24-Port Unloaded Patch Panel for UTP Cat6a Keystone Jacks

DESCRIPTION

Page 49: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com 49

Cat6

a So

lutio

n Pr

oduc

ts

VOICE PATCH PANELS

D-Link Voice patch panels are high density patch panelwith 50 RJ45 ports on 1U applied and suitable for22-26AWG stranded and solid wire, compatible with both110 & Krone punch down tools. D-Link patch panels haveimproved Cable Management with optional CableManagement bar terminating 4 pairs UTP cable. They arecomplied with the FCC Part 68 sub part F standard.

• 50 RJ45 ports on 1U• Numeral marking of ports on front of the panel• IDC compatible with 110 & Krone tool• Terminating 4 pairs, 22-26 AWG, shielded cable• High reliability and superior performance• Built in rear cable management

KEY FEATURES

Entire high-carbon steel outer frame with plastic powder coatingRJ45 jack frame material: PBT, 8 pin of the RJ45 jack.Punching Duration: 200 timesFCC ports inserting duration: 750 timesIDC:6-3 & 504 LSA-plus typeComplies with TIA/EIA-568-B-2 standard for Category 3 transmission

SPECIFICATIONS

NPP-5V1BLK501

PART CODE

ORDERING INFORMATION

50-Port Voice Patch Panel

DESCRIPTION

Page 50: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

50 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

FACEPLATES & MODULAR INSERTS

D-Link offers a range of high quality, stylish designed Faceplates for professional installations, fully compliant for copper cabling systems. The Faceplates are inbuilt with shutters which are compatible with any standard coloured keystones jacks. The Faceplates are available in one, two and four port variants.

• Stylish design to mount on the wall• Available in one, two and four port variants• ID stripes for easy identification• Compatible with Cat5e/Cat6/Cat6a keystone jacks

KEY FEATURES

SPECIFICATIONS

UK style with shutter against dust and labeling plateID Plate: PC, Transparent ColourFaceplate: ABS with White ColourDust Cover: ABS with White ColourScrew: M3.5XL25.0mmFrench Style with shutter against dustFlush Mount Plate Faceplate: ABS, UL-94HB, with white Colour.Bracket: Metal, blue zine platedScrew: M3.5 X 25.0mm X 7.0mmModular InsertsDust Cover: ABS, UL-94HBFront Bracket: ABS, UL-94HBBack Bracket: ABS, UL-94HBSpring: SUS

Angled Floor Module HolderPlate: ABS White ColourID Plate: ABSDust Cover: ABSBack Insert: ABSSpring: Stainless SteelOperating Temperature: -10°C to +60°CAngle: 45°

NFP-0WHI11NFP-0WHI21NFP-0WHI22 NFP-0WHI41NFF-01WHINMI-11WHI01B2NMI-11WHI01B3 NMI-12WHI01B1

PART CODE

ORDERING INFORMATION

86*86 mm, Single UK Faceplate accepts one keystone jack86*86 mm, Dual UK Faceplate accepts two keystone jacks86*86 mm, Dual Angled UK Faceplate accepts two keystone jacks146*86 mm, Quad UK Faceplate accepts four keystone jacks80*80mm, Flush-Mounted French Faceplate Frame45x45mm, Modular Insert for French Faceplate22.5x45mm, Modular Insert for French FaceplateAngled Floor Module Holder

DESCRIPTION

Page 51: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com 51

Cat6

a So

lutio

n Pr

oduc

ts

KEYSTONE BOXES

D-Link offers a range of high quality, stylish designedkeystone boxes for professional installations, fullycompliant for copper cabling systems. The Keystone boxesare inbuilt with shutters which are compatible with anystandard Coloured keystones jacks. They are available in oneand two port variants.

• Stylish Design to mount on wall or other surfaces• ID stripes for identifying port allocations• Compatible with RJ45 Keystone jacks

KEY FEATURES

ID Plate:Box:Insert:Dust Cover:Screw:

Surface Mount Box, accepting Keystone Jacks (including CAT5e and CAT6)PC, UL94V-2 transparent ColourABS, UL 94V-0, with white ColourABS, UL 94V-0ABS+PC, UL 94V-00.4X14mm

SPECIFICATIONS

NKB-1WHI11NKB-1WHI21

PART CODE

ORDERING INFORMATION

Single port keystone box with shutter, 37x65x30mmDual ports keystone box with shutter, 63x65x30mm

DESCRIPTION

Page 52: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

52 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

BACK BOXES

D-Link Backboxes are available suitable for bothsingle, dual and quad Faceplates.

• Single and dual gang configuration• Suitable for flat and angled faceplates• Breakaway cable entries

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

For UK/EU Style Faceplate, White ColourBox: ABS, with White ColourScrew Nut: 3.5x5x6mmScrew: 3.5x25mm

For French Style Faceplate, White ColourBox: ABS, UL94-HB, with White ColourScrew Nut: 5.5x6.5mmScrew: M3.5X17.6x6.6 mmScrew: M3.5X19.0X7.5mm

NBB-011NBB-111NBB-211

86 x 86x 37mm Back Box for Single and Dual UK Faceplate146 x 86 x 32mm Back Box for rectangular Quad Faceplate80x 80 mm Back Box for Single and Dual French Faceplate

PART CODE DESCRIPTION

Page 53: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com 53

Cat6

a So

lutio

n Pr

oduc

ts

MODULAR PLUGS

D-Link Category 6 Modular Plugs are suitable for both 24-26 AWG stranded and solid cables. This modular design means they can be used for a wide range of networking needs that span across a whole business system, eliminating the need to constantly switch between plugs when cabling. Compatible with standard RJ45 Wire network crimping tools, D-Link CAT6 modular plugs fit seamlessly into any well-established standard operating procedure, making cable assembly easy.

• Fits 24-26 AWG• Reliable and fast connection• 50 micro-inch thick gold plating• Polycarbonate housing

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

UTP Modular Plugs RJ45 Jack Housing & Insert: PC, UL94V-2RJ45 Jack Contact Terminal Material: Phosphor bronzeRJ45 Jack Contact Terminal Finish: 50 micro-inch gold platingOperating Temperature: -40 °C to 80°C FTP Modular Plugs: RJ45 Jack Housing & Insert: PC, UL94V-2 RJ45 Jack Contact Terminal Material: Phosphor bronze with 100 micro-inch nickel plating on contact areaRJ45 Jack Contact Terminal Finish: 50 micro-inch gold platingInsertion Cycles: 2000 timesRJ45 Jack Shield: Bronze with Nickel platingOperating Temperature: -40°C to 125°C

NPG-5E1TRA501-100NPG-C61TRA501-100NPG-C61MET502-100

Cat5e UTP Modular Plugs (100 Units/Pack)Cat6 UTP Modular Plugs (100 Units/Pack)Cat6 FTP Modular Plugs (100 Units/Pack)

PART CODE DESCRIPTION

Page 54: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

54 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

CABLE MANAGERS

A range of cable management bars designed to fit instandard 19” racks and cabinets.It mounts on standardcabinets to provide a clean,beautiful and simple means oforganizing from small bundles to large bundles of cablesand patch cords.The cable managers are available withmetal rings type, brush manager type and metal cablemanagement bar with cover.

• Available in metal and brush type• Neat management of patch cables• Horizontal cable management• Mounts on 19” racks or cabinets

SPECIFICATIONS ORDERING INFORMATION

KEY FEATURES

19” 1U Metal cable management with ringsSPCC cold rolled steel1.2 - 1.8mm thickness (Body-1.2 mm, Ring-1.8 mm)483 * 44.45 * 63.12 mm

19” 1U Brush ManagerSPCC cold rolled steel + PA Brush1.5mm thickness483 * 44.3 * 9 mm

19” 1U Metal Cable Management with Cover19” Rack InstallationAluminium Alloy Body482.6mm x 70mm x 1U

19” 1U CCS-Type Metal Cable Management with Cover

19” Rack InstallationCold-Rolled Steel Body482.6mm x 50mm x 1U

NCM-B01NCM-M01NCM-M02NCM-M03

19” 1U Brush Manager19” 1U Metal cable management with rings19” 1U Metal cable management with cover19” 1U CCS-Type Metal Cable Management with Cover

PART CODE DESCRIPTION

Page 55: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com 55

Cat6

a So

lutio

n Pr

oduc

ts

NETWORK TOOLS

The D-Link Modular Plug Crimper is suitable for the crimping of RJ45, RJ11 and RJ12 modular plugs. It fits 22-26 AWG wires.

The Punch Down Tool helps with the termination of twisted pair cables to the keystone jacks. The colour-coded yellow handle on the cut side of the tool reduces the chance for termination errors. The simplified internal impact mechanism eliminates jamming for longer, trouble-free service.

Modular Plug Crimper

Punch-Down Tool

PUNCH-DOWN TOOL• Adjustable low and high impact force settings allow the punch-down tool to be set according to the user’s preference

• Blades are made from heat-treated, high- carbon tool steel with a black-oxide, rust-resistant finish and a precision-ground cutting surface for long life

MODULAR PLUG CRIMPER

• D-Link crimping tools have all-steel handles (with padding)

• Built-in cable stripper with stop to ensure correct strip length continuity tester

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

• 7.3 inch steel construction body• Weight: 130 gms

NTP-001NTC-001

Punch Down ToolModular Plug Crimper

PART CODE DESCRIPTION

• 7.5 inch steel construction body• Weight: 280 gms• Suitable for 22-26 AWG wires

Page 56: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

56 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

NETWORK LAN TESTER

The D-Link LAN Tester can be used for testing RJ45 cables, RJ11 telephone cables and network cables. It keeps your network running smoothly by testing wrong connection, short circuit and open circuit. the two-part unit can be separated for remote closet testing.

• Visible LED status display.• Check the RJ11& RJ45 Cable quickly. • Automatically runs all tests and checks for continutiy, open,shorted and crossed wire pairs. • Slow and fast test switch.

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

Main Function: Verify RJ11, RJ45 cables Tracking Type: RJ11 & RJ45Power: 9V Alkaline battery (battery not included)

NTL-CT-001 Cable Tester - Detected Cable Type: RJ11, RJ45

PART CODE DESCRIPTION

Page 57: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com 57

Cat6

a So

lutio

n Pr

oduc

ts

VELCRO CABLE TIE

The perfect, re-usable solution shortening, bundling or simply securing a multitude of items. The cut-to-length role ensures you get the right amount of tape for the job.

• Simply wrap and press to secure• Self-attaching hook-and-loop tape• Easy to install, resuable, flexible and superior strength• Available in a wide variety of sizes • Help to keep your cables tidy and easy to identify; Perfect for Computer applicance, electronic cord organization, wire management and storage

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

• Color: Black • Width: 10mm • Material: 100% Nylon • Length: 5 Meters • Weight: 30g/bag

• Color: Black • Width: 25mm • Material: 100% Nylon • Length: 5 Meters • Weight: 55g/bag

NVC-010 NVC-025

Velcro Cable Tie - Width: 10mm Length: 5m (Black Colour) with PE BagVelcro Cable Tie - Width: 25mm Length: 5m (Black Colour) with PE Bag

PART CODE DESCRIPTION

NVC-010 NVC-025

Page 58: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

ucts

Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

58 www.dlinkmea.com

Cat6

a So

lutio

n Pr

oduc

ts

• Size: 9.3cm (length) x 3cm (wide) x 0.55cm (high)• Material: PP+ Mn65 (knife blade) • Color: Yellow • Weight: 11g

• Size: 10.9cm (length) x 5.7cm (wide) x 1.5cm (high)• Material: PA+ Mn65 (knife blade) • Color: Gray • Weight: 36g

CABLE STRIPPER

This stripper is easy and safe to use, punch down wires on modular connectors. Strip twisted-pair UTP/STP data cables and wires and terminates wires into 110 blocks. It's great for CAT-5e, and CAT-6 data cables. This wire stripper is small and exquisite, which is very convenient and practical. It cuts cables with different thickness and cuts very clean and takes only few seconds small and simple tool for cable or wire stripping.

• For round and flat cable• Strips computer cable, power and speaker cable, bell wire• twisted pair data/telecom wire• Multi-function• Features adjustable capacity and spring-assisted opening

• Adjustable stripping blade for different insulation thickness

• Easy to adjust with thumb screw and cable cutter

SPECIFICATIONS

ORDERING INFORMATION

KEY FEATURES

NTS-001 NTS-002

Cable Stripper - PE Bag (5 units)Cable Stripper with Adjustable Bolt

PART CODE DESCRIPTION

NTS-001 NTS-002

Fiber Solutions

Page 59: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Fiber Solutions

OPTIC FIBER CABLES

FIBER PATCH CORDS

FIBER PIGTAILS

FC CONNECTORS

LC CONNECTORS

SC CONNECTORS

ST CONNECTORS

ADAPTERS

FC ADAPTERS

LC ADAPTERS

SC ADAPTERS

ADAPTER PANELS

FIBER LIU

MICRO ODF

PLC SPLITTERS

59www.dlinkmea.comwww.dlinkmea.com

Page 60: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

60 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• Central Loose tube with jelly compound• Glass yarns in between Steel tape & loose tube• Corrugated, armoured Steel tape

DESCRIPTION

STANDARDS

MECHANICAL & ENVIRONMENT CHARACTERISTICS

OPTICAL FIBER CHARACTERISTICS

APPLICATIONS

COLOUR CODE

• ISO 11801• IEC 60793-1/60794-1-2• ITU-T REC G.652D• Telcordia GR-20-core • Suitable for Indoor / Outdoor Local Area network System.

• Excellent crush resistant performance, light weight, compact

BL-BLUE OR-ORANGE GR-GREEN BR-BROWN GY-GREY WH-WHITERD-RED BK-BLACK YE-YELLOW PU-PURPLE PI-PINK AQ-AQUA

24**- Core contains two bundles of 12F in Blue & Orange Colour bundle

* Effective Modal Bandwidth at 850nm for OM3

OPTIC FIBER CABLES - ARMOURED

Operating Temperature: -20°C to +70°C Storage Temperature: -40°C to +70°C Jacket Material: LSZH/HDPE

Fiber Type 9/125µm (SM) 62.5/125µm (OM1) 50/125µm (0M2) 50/125µm (OM3)

Operational Wavelength 1310nm 1550nm 850nm 1300nm 850nm 1300nm 850nm 1300nm

Maximum Attenuation (dblkm) 0.36 0.22 3.5 1.5 3.5 1.5 2.7 0.8

Minimum Bandwidth (Mhz—km) — — 200 600 500 550 1500/2000* 500

OUTER SHEATH (H.D.P.E./L.S.Z.H)

CORRUGATED STEEL TAPE

OPTICAL FIBREFILLING JELLYRIP CORDGLASS YARN REINFORCEMENT

LOOSE TUBE WITH FIBRES

STEEL WIRE

HDPE – High Density Polyethylene

Single Mode Multimode 62.5µm (OM1) Multimode 50µm (OM2) Multimode 50µm (OM3)

4 Fibers NCB-FS09O-AUHD-04 NCB-FM62O-AUHD-04 NCB-FM50O-AUHD-04 NCB-FM51O-AUHD-04

6 Fibers NCB-FS09O-AUHD-06 NCB-FM62O-AUHD-06 NCB-FM50O-AUHD-06 NCB-FM51O-AUHD-06

12 Fibers NCB-FS09O-AUHD-12 NCB-FM62O-AUHD-12 NCB-FM50O-AUHD-12 NCB-FM51O-AUHD-12

24 Fibers NCB-FS09O-AUHD-24 NCB-FM62O-AUHD-24 NCB-FM50O-AUHD-24 NCB-FM51O-AUHD-24

LSZH – Low Smoke Zero Halogen

4 Fibers NCB-FS09O-AULS-04 NCB-FM62O-AULS-04 NCB-FM50O-AULS-04 NCB-FM51O-AULS-04

6 Fibers NCB-FS09O-AULS-06 NCB-FM62O-AULS-06 NCB-FM50O-AULS-06 NCB-FM51O-AULS-06

12 Fibers NCB-FS09O-AULS-12 NCB-FM62O-AULS-12 NCB-FM50O-AULS-12 NCB-FM51O-AULS-12

24 Fibers NCB-FS09O-AULS-24 NCB-FM62O-AULS-24 NCB-FM50O-AULS-24 NCB-FM51O-AULS-24

Page 61: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

61

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

Fiber Type 9/125µm (SM) 62.5/125µm (OM1) 50/125µm (0M2) 50/125µm (OM3)

Operational Wavelength 1310nm 1550nm 850nm 1300nm 850nm 1300nm 850nm 1300nm

Maximum Attenuation (dblkm) 0.36 0.22 3.5 1.5 3.5 1.5 2.7 0.8

Minimum Bandwidth (Mhz—km) — — 200 600 500 550 1500/2000* 500

HDPE – High Density Polyethylene

Single Mode Multimode 62.5µm (OM1) Multimode 50µm (OM2) Multimode 50µm (OM3)

4 Fibers NCB-FS09O-AUHD-04 NCB-FM62O-AUHD-04 NCB-FM50O-AUHD-04 NCB-FM51O-AUHD-04

6 Fibers NCB-FS09O-AUHD-06 NCB-FM62O-AUHD-06 NCB-FM50O-AUHD-06 NCB-FM51O-AUHD-06

12 Fibers NCB-FS09O-AUHD-12 NCB-FM62O-AUHD-12 NCB-FM50O-AUHD-12 NCB-FM51O-AUHD-12

24 Fibers NCB-FS09O-AUHD-24 NCB-FM62O-AUHD-24 NCB-FM50O-AUHD-24 NCB-FM51O-AUHD-24

LSZH – Low Smoke Zero Halogen

4 Fibers NCB-FS09O-AULS-04 NCB-FM62O-AULS-04 NCB-FM50O-AULS-04 NCB-FM51O-AULS-04

6 Fibers NCB-FS09O-AULS-06 NCB-FM62O-AULS-06 NCB-FM50O-AULS-06 NCB-FM51O-AULS-06

12 Fibers NCB-FS09O-AULS-12 NCB-FM62O-AULS-12 NCB-FM50O-AULS-12 NCB-FM51O-AULS-12

24 Fibers NCB-FS09O-AULS-24 NCB-FM62O-AULS-24 NCB-FM50O-AULS-24 NCB-FM51O-AULS-24

OPTIC FIBER CABLES - UNARMOURED

• Central Loose tube with jelly compound• E - glass strength members• Sequential Meter Marking

DESCRIPTION

STANDARDS

MECHANICAL & ENVIRONMENT CHARACTERISTICS

OPTICAL FIBER CHARACTERISTICS

APPLICATIONS

COLOUR CODE

• ISO 11801• IEC 60793-1/60794-1-2• ITU-T REC G.652D• Telcordia GR-20-core • Suitable for Indoor & Outdoor (duct), pipeline

• Lightweight, Small, Compact cable size

BL-BLUE OR-ORANGE GR-GREEN BR-BROWN GY-GREY WH-WHITERD-RED BK-BLACK YE-YELLOW PU-PURPLE PI-PINK AQ-AQUA

24C - Core contains two bundle of 12F in Blue & Orange Colour bundle

* Effective Modal Bandwidth at 850nm for OM3

Operating Temperature: -20°C to +70°C Storage Temperature: -40°C to +60°C Jacket Material: HDPE/LSZH

Fiber Type 9/125µm (SM) 62.5/125µm (0M1) 50/125µm (0M2) 50/125µm (OM3)

Operational Wavelength 1310nm 1550nm 850nm 1300nm 850nm 1300nm 850nm 1300nm

Maximum Attenuation (dblkm) 0.36 0.22 3.5 1.5 3.5 1.5 2.7 0.8

Minimum Bandwidth (Mhz—km) — — 200 600 500 550 1500/2000* 500

OUTER SHEATH (L.S.Z.H / H.D.P.E)

RIP CORD

GLASS YARN

FRP ROD

FILLING JELLYLOOSE TUBE WITH FIBRES

HDPE – High Density Polyethylene

Single Mode Multimode 62.5µm (OM1) Multimode 50µm (OM2) Multimode 50µm (OM3)

4 Fibers NCB-FS09X-UUHD-04 NCB-FM62X-UUHD-04 NCB-FM50X-UUHD-04 NCB-FM51X-UUHD-04

6 Fibers NCB-FS09X-UUHD-06 NCB-FM62X-UUHD-06 NCB-FM50X-UUHD-06 NCB-FM51X-UUHD-06

12 Fibers NCB-FS09X-UUHD-12 NCB-FM62X-UUHD-12 NCB-FM50X-UUHD-12 NCB-FM51X-UUHD-12

24 Fibers NCB-FS09X-UUHD-24 NCB-FM62X-UUHD-24 NCB-FM50X-UUHD-24 NCB-FM51X-UUHD-24

LSZH – Low Smoke Zero Halogen

4 Fibers NCB-FS09X-UULS-04 NCB-FM62X-UULS-04 NCB-FM50X-UULS-04 NCB-FM51X-UULS-04

6 Fibers NCB-FS09X-UULS-06 NCB-FM62X-UULS-06 NCB-FM50X-UULS-06 NCB-FM51X-UULS-06

12 Fibers NCB-FS09X-UULS-12 NCB-FM62X-UULS-12 NCB-FM50X-UULS-12 NCB-FM51X-UULS-12

24 Fibers NCB-FS09X-UULS-24 NCB-FM62X-UULS-24 NCB-FM50X-UULS-24 NCB-FM51X-UULS-24

Page 62: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

62 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• Tight Buffered fiber without jelly compound• Aramid yarn strength members• Round construction and termination can be made standard

DESCRIPTION

STANDARDS

MECHANICAL & ENVIRONMENT CHARACTERISTICS

APPLICATIONS

COLOUR CODE

• ISO 11801• IEC 60793-1/60794-1-2• ITU-T REC G.652D• Telecordia GR-20-core • Suitable for pipeline, bracket lying

• Suitable for indoor use• Light weight

BL-BLUE BR-BROWN RD-RED PU-PURPLE OR-ORANGE GY-GREYBL-BLACK PI-PINK GR-GREEN WH-WHITE YL-YELLOW AQ-AQUA

OPTIC FIBER CABLES - TIGHT-BUFFERED

Operating Temperature: -10°C to + 60°C Storage Temperature: -20°C to +85°C

Tight Buffer Material: PVC / LSZH Jacket Material: HDPE / LSZH

HDPE-High Density Polyethylene

Single Mode Multimode 62.5µm (OM1) Multimode 50µm (OM2) Multimode 50µm (OM3)

4 Fibers NCB-FS09I-UTHD-04 NCB-FM62I-UTHD-04 NCB-FM50I-UTHD-04 NCB-FM51I-UTHD-04

6 Fibers NCB-FS09I-UTHD-06 NCB-FM62I-UTHD-06 NCB-FM50I-UTHD-06 NCB-FM51I-UTHD-06

12 Fibers NCB-FS09I-UTHD-12 NCB-FM62I-UTHD-12 NCB-FM50I-UTHD-12 NCB-FM51I-UTHD-12

LSZH- Low Smoke Zero Halogen

4 Fibers NCB-FS09I-UTLS-04 NCB-FM62I-UTLS-04 NCB-FM50I-UTLS-04 NCB-FM51I-UTLS-04

6 Fibers NCB-FS09I-UTLS-06 NCB-FM62I-UTLS-06 NCB-FM50I-UTLS-06 NCB-FM51I-UTLS-06

12 Fibers NCB-FS09I-UTLS-12 NCB-FM62I-UTLS-12 NCB-FM50I-UTLS-12 NCB-FM51I-UTLS-12

OPTICAL FIBER CHARACTERISTICS

Fiber Type 9/125µm (SM) 62.5/125µm (0M1) 50/125µm (0M2) 50/125µm (OM3)

Operational Wavelength 1310nm 1550nm 850nm 1300nm 850nm 1300nm 850nm 1300nm

Maximum Attenuation (db/km) 0.36 0.22 3.5 1.5 3.5 1.5 2.7 1.0

Minimum Bandwidth (Mhz—km) — — 200 600 500 550 1500/2000* 500

OUTER SHEATH (L.S.Z.H / H.D.P.E)

TIGHT BUFFEREDOPTICAL FIBRES

ARAMID YARD

62

Page 63: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

63

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

HDPE-High Density Polyethylene

Single Mode Multimode 62.5µm (OM1) Multimode 50µm (OM2) Multimode 50µm (OM3)

4 Fibers NCB-FS09I-UTHD-04 NCB-FM62I-UTHD-04 NCB-FM50I-UTHD-04 NCB-FM51I-UTHD-04

6 Fibers NCB-FS09I-UTHD-06 NCB-FM62I-UTHD-06 NCB-FM50I-UTHD-06 NCB-FM51I-UTHD-06

12 Fibers NCB-FS09I-UTHD-12 NCB-FM62I-UTHD-12 NCB-FM50I-UTHD-12 NCB-FM51I-UTHD-12

LSZH- Low Smoke Zero Halogen

4 Fibers NCB-FS09I-UTLS-04 NCB-FM62I-UTLS-04 NCB-FM50I-UTLS-04 NCB-FM51I-UTLS-04

6 Fibers NCB-FS09I-UTLS-06 NCB-FM62I-UTLS-06 NCB-FM50I-UTLS-06 NCB-FM51I-UTLS-06

12 Fibers NCB-FS09I-UTLS-12 NCB-FM62I-UTLS-12 NCB-FM50I-UTLS-12 NCB-FM51I-UTLS-12

OPTIC FIBER CABLES - 2-CORE FTTH

• Single Mode Optical Fiber• Maximum Cabled Fiber Attenuation dB/Km at 1310nm: 0.38 dB/Km & at 1550nm: 0.28 dB/Km • Embedded Strength Member: Dielectric strength member• Sheathing: Low Smoke Zero Halogen • Colour Code: White/Black

DESCRIPTION

SPECIFICATIONS

• Flat drop cable is very light and easy to install and strip• Industry standard connectors can be used for direct termination because standard 250 µm fiber size• Coloured fiber for easy identification• Low Smoke Zero Halogen compound as outer jacket• Better for internal use

Fiber Count(Numbers)

Sheath Colour Fiber ColourWeight of Cable

Nominal (kg/km ± 10%)

Cable Size(Height : +0.2 mm, Width:

+0.2mm)2 White/Black Blue & Orange 8kg/km 2.0mm x 3.0mm

4 White/Black Blue, Orange, Green & Brown 8kg/km 2.0mm x 3.0mm

Test Test Standard Testing Value Acceptance Criteria

Tensile Strength IEC-60794-1-2-E1 100N

Change in attenuation <0.05 db/km, No crack, no brake in fiber

Temperature Cycling IEC-60794-1-2-F1 -20°C to + 70°C

Cable Bend Radius IEC-60794-1-2-E11 15D

Crush Test IEC-60794-1-2-E3 500N/100mm

Part Number Description Colour

NCB-FS09X-FDLS-02 02 Core Single Mode Flat Drop FTTH Indoor Fiber Cable - LSZH Sheath White

NCB-FS09X-FBLS-02 02 Core Single Mode Flat Drop FTTH Indoor Fiber Cable - LSZH Sheath Black

NCB-FS09X-FDLS-04 04 Core Single Mode Flat Drop FTTH Indoor Fiber Cable - LSZH Sheath White

NCB-FS09X-FBLS-04 04 Core Single Mode Flat Drop FTTH Indoor Fiber Cable - LSZH Sheath Black

D-Link FTTH Fiber Cable is an enhanced performance FTTH solution, constructed with single mode/bend sensitive fibers (ITU-TG657A/G652D), protected by two strength member having a final LSZH jacket, used for FTTX/FTTH application between the apartment’s central communication room and the apartment/office point. Cable enclosed a 0.250mm fiber, and it’s suitable for standard connector of industry.

Page 64: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

64 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• Adopts high precision ceramic ferrule with good concentricity• Good geometrical characteristics of apex offset, radius of curvature & fiber height• Compact & strong crimping offers exceptional tensile strength in cable assemblies• 100% inspected for optical characteristics & fiber end-face finish• Low insertion loss & return loss, clean and scratch-free end faces• Good performance endurance under changing circumstances• Strength member-aramid yarn

KEY FEATURES

FIBER PATCH CORDS - SIMPLEX & DUPLEX

Connector Type SC/ ST/ FC/ LC/ MTRJ

Optical FiberSingle-modeG652D, G657A, G657B

Multimode0M1, 0M2, 0M3, 0M4

Cable TypePVC & LSZH on request0.9mm/ 2.0mm/ 3.0mm Simplex & Duplex

Cable Colour, LengthYellow for Single-mode & Orange for Multi-mode & Aqua for 0M31 m, 2m & 3m. Other lengths on request.

Optical Specification

Insertion LossTypical: ≤ 0.2dB, Max. 0.3dB(MTRJ: Max. 0.5dB)

Typical: ≤ 0.2dB, Max. 0.3dB(MTRJ: Max. 0.5dB)

Return LossPC ≥ 45dB, UPC ≥ 50 dB,APC ≥ 60dB

≥30dB

Mechanical Specification

Connector Ferrule Ceramic, (MTRJ: PS- Polyphenylene Sulphide)

Apex Offset < 50um

Fiber Height ± 100nm

End-face Radiusof Curvature

7mm < R < 25mm (Excluding MTRJ)

Repeatability ≤ 0.2dB 1,000 times mating cycles

Working Temperature -40°C ~ + 85°C

Storage Temperature -40°C ~ + 85°C

D-Link offers standard simplex & duplex patch cords in a variety of con-nectors & cables configurations. D-Link patch cords are available with full standard optical specifications, precise length tolerances. All assemblies are 100% inspected for optical characteristics and fiber end face finish. The optical fiber patch cords are suitable for data communication, telecommunication applications. The terminated connectors in assemblies are designed to and are compatible with industry standards (EIA/TIA, IEC, ANSI, NTT and Telcordia). D-Link can deliver customized patch cords as per requirement.

Page 65: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

65

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

ORDERING INFORMATION

The above patch cords are available in 2M and 3M length, other lengths are available on request. Patch cords are available in APC versions also.

NCB -X-X-XX-X-XXXX-X/XXFAMILY

CATEGORY TYPEF (Fiber)

LENGTH1, 2, 3, 5, 10, 20, 40 Meters other lengths available on request

FIBER TYPESM (Multimode)S (Single Mode)

CONNECTOR TYPEST-ST SC-FC MT-MTST-SC LC-LC MT-STSC-SC LC-ST MT-SCST-FC LC-SC

CABLE THICKNESS62.5 (OM1)50 (OM2)51/52/53 (OM3)09 (Single Mode)

CABLE TYPES (Simplex)D (Duplex)

PRODUCT NOMENCLATURE - FIBER PATCH CORDS

Type-Length Single Mode(09um-OS 1)

Multi Mode( 62.5 um-0M1)

Multi Mode(50um-0M2)

Multi Mode(51um-0M3)

Simplex-1m

NCB-FS09S-STSC-1NCB-FS09S-STST-1NCB-FS09S-SCSC-1NCB-FS09S-LCSC-1NCB-FS09S-LCLC-1

NCB-FM62S-STST-1NCB-FM62S-STSC-1NCB-FM62S-SCSC-1NCB-FM62S-LCST-1NCB-FM62S-LCSC-1NCB-FM62S-LCLC-1

NCB-FM50S-STST-1NCB-FM50S-STSC-1NCB-FM50S-SCSC-1NCB-FM50S-LCSC-1NCB-FM50S-LCLC-1NCB-FM50S-LCST-1

NCB-FM51S-STST-1NCB-FM51S-STSC-1NCB-FM51S-SCSC-1NCB-FM51S-LCSC-1NCB-FM51S-LCLC-1

Duplex-1m

NCB-FS09D-STST-1NCB-FS09D-SCSC-1NCB-FS09D-STSC-1NCB-FS09D-STFC-1NCB-FS09D-SCFC-1NCB-FS09D-LCST-1NCB-FS09D-LCSC-1NCB-FS09D-LCLC-1

NCB-FM62D-STST-1NCB-FM62D-STSC-1NCB-FM62D-SCSC-1NCB-FM62D-MTST-1NCB-FM62D-MTSC-1NCB-FM62D-MTMT-1NCB-FM62D-LCST-1NCB-FM62D-LCSC-1NCB-FM62D-LCLC-1

NCB-FM50D-STST-1NCB-FM50D-STSC-1NCB-FM50D-SCSC-1NCB-FM500-MTST-1NCB-FM50D-MTSC-1NCB-FM50D-MTMT-1NCB-FM50D-LCSC-1NCB-FM50D-LCLC-1NCB-FM50D-LCST-1

NCB-FM51D-STST-1NCB-FM51D-STSC-1NCB-FM51D-SCSC-1NCB-FM51D-MTST-1NCB-FM51D-MTSC-1NCB-FM51D-MTMT-1NCB-FM51D-LCSC-1NCB-FM51D-LCLC-1

Page 66: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

66 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

Type-Length Single Mode(09µm)

Multi Mode( 62.5µm-0M1)

Multi Mode(50µm-0M2)

Multi Mode(51µm-0M3)

Simplex1m

NCB-FS09S-FC1 NCB-FS09S-SC1NCB-FS09S-ST1 NCB-FS09S-LC1

NCB-FM62S-LC1NCB-FM62S-SC1NCB-FM62S-ST1

NCB-FM50S-LC1NCB-FM50S-ST1NCB-FM50S-SC1

NCB-FM51S-LC1NCB-FM51S-SC1

SimplexLSZH-1m

NCB-FS09S-FC1-LSNCB-FS09S-SC1-LSNCB-FS09S-ST1-LSNCB-FS09S-LC1-LS

NCB-FM62S-LC1-LSNCB-FM62S-SC1-LSNCB-FM62S-ST1-LS

NCB-FM50S-LC1-LSNCB-FM50S-ST1-LSNCB-FM50S-SC1-LS

NCB-FM51S-LC1-LSNCB-FM51S-SC1-LS

• Adopts high precision ceramic ferrule with good concentricity• Advanced termination facilities & process, deliver good geometrical characteristics of apex offset, radius of curvature & fiber height.• 100% inspected for optical characteristics & fiber end face finish• Low insertion loss & return loss, clean and scratch-free end faces• Good performance endurance under changing circumstances

KEY FEATURES

FIBER OPTIC COMPONENTS – PIGTAILS

D-Link offers quality optical fiber pigtails which are single ended with connectors. D-Link pigtails come with good endface geometry, full standard optical specifications, precise length & tolerances. The pre-polished pigtail assemblies give the quality, confidence & convenience to be installed & spliced in the field.

STANDARDS

ORDERING INFORMATION

Connector Type SC/ ST/ FC/ LC

Optical FiberSingle-modeG652D, G657A, G657B

Multimode0M1, 0M2, 0M3, 0M4

Cable TypePVC & LSZH on request0.9mm/ 2.0mm/ 3.0mm Simplex & duplex

Cable Colour, LengthYellow for Single-mode & Orange for Multi-mode & Aqua for 0M31m, 2m & 3m. Other lengths on request.

Optical SpecificationInsertion Loss Typical: ≤ 0.2dB, Max. 0.3dB Typical: ≤ 0.2dB, Max. 0.3dB

Return Loss PC ≥ 45dB, UPC ≥ 50 dB, APC ≥ 60dB ≥30dB

Mechanical Specification

Connector Ferrule Ceramic

Apex Offset < 50um

Fiber Height ± 100nm

End-face Radiusof Curvature

7mm < R < 25mm (Excluding MTRJ)

Repeatability ≤ 0.2dB 1,000 times mating cycles

Working Temperature -40°C ~ + 85°C

Storage Temperature -40°C ~ + 85°C

The above pigtails are available in 2M and 3M length. The pigtails are available in APC versions also.

Page 67: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

67

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• High Precision Ceramic Ferrule• High Precision Nickel plated brass housing• 900µm and 3mm strain relief boot

KEY FEATURES

FIBER OPTIC COMPONENTS | FC CONNECTORS

D-Link adopts high precision equipments in fiber connector product line providing the highest levels of reliability and performance. Each FC simplex optical fiber con-nector has a 2.5mm ceramic ferrule which is housed in a nickel plated brass housing. Available in both Singlemode and Multimode, connectors come with a 900µm and 3mm strain relief boot. Good for use with pigtail and buffered fiber cables.

ORDERING INFORMATION

SPECIFICATIONS

Measure FC Connector

Insertion Loss dB (Single and Multi Mode): < 0.3 Return Loss: > 55dB UPC Style Ferrule > 60dB APC Style FerrulePigtail Boot: 900 µm black (Multi mode) blue (Single mode)Cable Boot: 3mm black (Multi mode), blue (Single mode) 2mm upon requestMating Cycle: Up to 1000 timesFerrule Diameter: 2.5mm ± 0.001Ferrule Tolerance Single Mode: 126 ± 0.5 µm internalFerrule Tolerance Multi Mode: 127 ± 0.5 µm internalFinish: Pre-radiused PC end, radius 10 to 25mmOperating Temperture: - 40°C to + 85°CMeet Standard: IEC61754-20 Optical Fiber Connector InterfaceDurability: IEC61300-2-2 Fiber Optic Interconnecting DevicesPerformance IEC61753-1 Optical Fiber interconnecting devices and passive components performance standard

NCO-FSSFCXX

PART CODE

Connector SM FC/PC type

DESCRIPTION

Page 68: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

68 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• High Precision Ceramic Ferrule• High Precision Polymer housing• Simplex or Duplex at your choice• Beige for Multi mode and Blue for Single mode• APC Green Polymer housing with 900µm and 3mm strain relief boot

KEY FEATURES

FIBER OPTIC COMPONENTS | LC CONNECTORS

D-Link adopts high-precision equipments in fiber connector product line providing the highest levels of reliability and performance. Each LC simplex optical fiber connector has a 1.25mm ceramic ferrule which is housed in a colour-coded polymer frame. Available in both Singlemode and Multimode, connectors come with a 900µm and 3mm strain relief boot. Good for use with pigtail and buffered fiber cables.

ORDERING INFORMATION

SPECIFICATIONS

Measure LC Connector

Insertion Loss dB (Single and Multi Mode): < 0.3Return Loss: > 55dB UPC Style Ferrule > 60dB APC Style FerruleCable Boot: 2mm white, 3mm upon requestMating Cycle: Up to 1000 timesFerrule Diameter: 1.25mm ± 0.001Ferrule Tolerance Single Mode: 126 ± 0.5 µm internalFerrule Tolerance Multi Mode: 127 ± 0.5 µm internalFinish: Pre-radiused PC end, radius 10 to 25mmOperating Temperature: – 40°C to + 85°CMeet Standard: IEC61754-20 Optical Fiber Connector InterfaceDurability: IEC61300-2-2 Fiber Optic Interconnecting DevicesPerformance: IEC61753-1 Optical Fiber interconnecting devices and passive components performance standard

NCO-FSSLCXXNCO-FMSLC20

PART CODE

Connector SM LC StyleConnector MM LC Style

DESCRIPTION

Page 69: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

69

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• High Precision Ceramic Ferrule• High Precision Polymer housing• Quick conversion to duplex with a joint clip• Beige for Multi mode and Blue for Single mode• APC Green Polymer housing with 900µm and 3mm strain relief boot

KEY FEATURES

FIBER OPTIC COMPONENTS | SC CONNECTORS

D-Link adopts high precision equipments in fiber connector product line providing the highest levels of reliability and performance. Each SC simplex optical fiber connector has a 2.5mm ceramic ferrule which is housed in a Colour coded polymer frame. Special design allow quick conversion to a duplex style connector by the use of a simple jointing clip.

Available in both Single mode-blue housing and Multi mode-beige housing, connectors come with a 900µm and 3mm strain relief boot. Good for use with pigtail and buffered fiber cables.

ORDERING INFORMATION

SPECIFICATIONS

Measure SC Connector

Insertion Loss dB (Singlemode and Multimode): < 0.3Return Loss: > 50dB UPC Style Ferrule > 60dB APC Style FerrulePigtail Boot: 900µm beige (Multi mode) blue (Single mode)Cable Boot: 3mm beige (Multi mode), blue (Single mode) 2mm upon requestMating Cycle: Up to 1000 timesFerrule Diameter: 2.5mm ± 0.001Ferrule Tolerance Single Mode: 126 ± 0.5 µm internalFerrule Tolerance Multi Mode: 127 ± 0.5 µm internalFinish: Pre-radiused PC end, radius 10 to 25mmOperating Temperature: – 40°C to + 85°CMeet Standard: IEC61754-20 Optical Fiber Connector InterfaceDurability: IEC61300-2-2 Fiber Optic Interconnecting DevicesPerformance: IEC61753-1 Optical Fiber interconnecting devices and passive components performance standard

NCO-FSSSC09NCO-FMSSC09

PART CODE

Connector SM SC typeConnector MM SC type

DESCRIPTION

Page 70: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

70 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• High Precision Ceramic Ferrule• High Precision Nickel Plated Brass housing• Come with a 900µm and 3mm strain relief boot

KEY FEATURES

FIBER OPTIC COMPONENTS | ST CONNECTORS

At D-Link, we adopt high precision equipments in fiber connectorsproduct line providing the highest levels of reliability andperformance. Each connector has a 2.5mm ceramic ferrule which ishoused in a nickel plated brass housing. Available in both Single andMulti mode, connectors come with a 900µm and 3mm strainrelief boot. Good for use with pigtail and buffered fiber cables.

ORDERING INFORMATION

SPECIFICATIONS

Measure ST Connector

Insertion Loss dB (Single and Multi Mode): < 0.3Return Loss: > 50dB UPC Style FerrulePigtail Boot: 900µm black (MM) yellow (SM)Cable Boot: 3mm black, 2mm upon requestMating Cycle: Up to 1000 timesFerrule Diameter: 2.5mm ± 0.001Ferrule Tolerance Single Mode: 126 ± 0.5 µm internalFerrule Tolerance Multi Mode: 127 ± 0.5 µm internalFinish: Pre-radiused PC end, radius 10 to 25mmOperating Temperature: – 40°C to + 85°CMeet Standard: IEC61754-20 Optical Fiber Connector InterfaceDurability: IEC61300-2-2 Fiber Optic Interconnecting DevicesPerformance: IEC61753-1 Optical Fiber interconnecting devices and passive components performance standard

NCO-FMSST09NCO-FSSST09

PART CODE

Connector MM ST StyleConnector SM ST Style

DESCRIPTION

Page 71: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

71

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• Compact design• Telcordia, TIA/EIA, IEC compliance• High precision alignment• Low insertion and return loss• Screw-type locking stable and reliable• Square Type design

KEY FEATURES

FIBER OPTIC COMPONENTS | FC ADAPTERS

D-Link offers high quality FC adapters that have compact design & high precision, which perform well under various circumstances & maintain good plug retention strength. The female-female threaded adapter provides extremely accurate key alignment to enhance connector loss performance, fully compliant to TIA/EIA, IEC standards. All these FC adapters are with metal housing and zirconia sleeves.

SPECIFICATIONS

Insertion Loss: ≤ 0.20dB for Zirconia SleeveSleeve/Ferrule Withdrawal Force: 2.0N ~ 5.9N

ORDERING INFORMATION

NAD-FSSFCFC

PART CODE

SINGLE MODE

ADAPTER FC SM SIMPLEX

DESCRIPTION

APPLICATIONS

• Telecommunication networks• LAN• Data communications• Optical equipments• Fiber-To-The-Home• Premises distribution

Page 72: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

72 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

KEY FEATURES

FIBER OPTIC COMPONENTS | LC ADAPTERS

D-Link offers a full range of LC adapters with high precision alignment sleeves for improved reliability and better reconnectability. The LC adapters feature a self-adjusting mechanism designed to accommodate panels of thickness. Duplex LC fiber adapters are with SC footprint. D-Link LC Adapter is designed to work together with the complete LC product family to offer an optimal, high- density solution for your network. The LC adapters come with zirconia sleeves for both single mode and multimode use.

SPECIFICATIONS

Insertion Loss: ≤0.20dB for Zirconia SleeveSleevelFerrule Withdrawal Force: 1.0N — 2.5N

ORDERING INFORMATION

ORDERING INFORMATION

NAD-FSSLCLCNAD-FSDLCLCNAD-FSDLCLC-APC

NAD-FMSLCLCNAD-FMDLCLC

PART CODE

PART CODE

SINGLE MODE

MULTI MODE

ADAPTER LC SM SIMPLEXADAPTER LC SM DUPLEXADAPTER LC/APC SM DUPLEX

ADAPTER LC MM SIMPLEXADAPTER LC MM DUPLEX

DESCRIPTION

DESCRIPTION

APPLICATIONS

• Telecommunication networks• LAN• Data communications• Optical equipments• Fiber-To-The-Home• Premises distribution

• Compact design• Telcordia, TIAIEIA, IEC compliance• High precision alignment• Low insertion and return loss• Self-adjusting metal panel clips• Duplex adapters are with SC footprint

Page 73: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

73

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• Compact design• Telcordia, TIAIEIA, IEC compliance• High precision alignment• Low insertion and return loss

KEY FEATURES

FIBER OPTIC COMPONENTS | SC ADAPTERS

D-Link offers a full range of SC adapters that have compact design & high precision, which perform well under various circumstances & maintain good plug retention strength. Simplex and duplex adapters are available. The sleeves are basically recommended zirconia split type, the phosphor bronze split.

SPECIFICATIONS

Insertion Loss: ≤0.20dB for Zirconia SleeveSleeve/Ferrule Withdrawal Force: 2.0N — 5.9N

ORDERING INFORMATION

ORDERING INFORMATION

NAD-FSSSCSCNAD-FSDSCSCNAD-FSSSCSC-APCNAD-FSDSCSC-APC

NAD-FMSSCSCNAD-FMDSCSC

PART CODE

PART CODE

SINGLE MODE

MULTI MODE

ADAPTER SC SM SIMPLEXADAPTER SC SM DUPLEX ADAPTER SC/APC SM SIMPLEXADAPTER SC/APC SM DUPLEX

ADAPTER SC MM SIMPLEXADAPTER SC MM DUPLEX

DESCRIPTION

DESCRIPTION

APPLICATIONS

• Telecommunication networks• LAN• Data communications• Optical equipments

Page 74: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

74 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• Compact design• Telcordia, TIA/EIA, IEC compliance• High precision alignment• Low insertion and return loss• Threaded with nuts or snap-in coupling• Body zinc alloy for long life

KEY FEATURES

FIBER OPTIC COMPONENTS | ST ADAPTERS

D-Link offers a full range of ST adapters which are comprised of metal outer body and inner assembly fitted with a precision alignment mechanism. The ST adapters set the standard for optical fiber interconnects. These come with a D-Hole profile and retaining nut, which prevents accidental disconnection. The combination of a zirconia alignment sleeves and precision metal housing provides consistent long-term mechanical and good optical performance.

SPECIFICATIONS

Insertion Loss: ≤0.20dB for Zirconia SleeveSleeve/Ferrule Withdrawal Force: 2.0N ~ 5.9N

ORDERING INFORMATION

ORDERING INFORMATION

NAD-FSSSTST

NAD-FMSSTST

PART CODE

PART CODE

SINGLE MODE

MULTI MODE

ADAPTER ST SM SIMPLEX

ADAPTER ST MM SIMPLEX

DESCRIPTION

DESCRIPTION

APPLICATIONS

• Telecommunication networks• LAN• Data communications• Optical equipments• Fiber-To-The-Home• Premises distribution

Page 75: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

75

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• Cold rolled steel materials• Available in 4-24 holes (according to the type of adapters)• Offer type of 175,109 size module panels, other dimension and type according to customers' request• Suitable for FC, LC, SC, ST adapters• Panel fastener to hold adapter panels securely in place• Ideal for simple moves, adds and changes

KEY FEATURES

FIBER OPTIC COMPONENTS | ADAPTER PANELS

D-Link offers comprehensive range of adapter panel which enhanceinstallation flexibility and convenience. The panel is pre-loaded withadapters and can snap in for installation and can be removed easilyfor future changes. Blank fiber adapter panels reserve fiber adapterpanel space for future use. All fiber adapter panels snap quickly intothe front of fiber optic patch panels and enclosures for easy networkdeployment or moves, adds and changes.

SPECIFICATIONS

ORDERING INFORMATION

APPLICATIONS

• Installation and management of fiber optic patch cords and pigtails• Used with rack mount, both fixed and sliding fiber optic patch panel and wall mount distribution box • High-density fiber optic network application

Part Code Description

NPL-FXXSC-06 Blank Adapter Panel to be loaded with 6 Simplex SC/6 Duplex LC Adapters

NPL-FXXLC-06 Blank Adapter Panel to be loaded with 6 Simplex LC Adapters

NPL-FXXSC-12 Blank Adapter Panel to be loaded with 12 Simplex SC/12 Duplex LC Adapters

NPL-FXXFC-12 Blank Adapter Panel to be loaded with 12 Simplex FC Adapters

NPL-FXXST-12 Blank Adapter Panel to be loaded with 12 Simplex ST Adapters

NPL-FXDSC-03 Blank Adapter Panel to be loaded with 3 Duplex SC Adapters

NPL-FXDSC-06 Blank Adapter Panel to be loaded with 6 Duplex SC Adapters

NPL-FXDSC-12 Blank Adapter Panel to be loaded with 12 Duplex SC Adapters

Page 76: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

76 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• Aluminum base material with powder coating for light mounting• Slim 1U & 2U Unit Mounting Height• Front-mounted cable saddles for jumper management• Can manage both splices and terminations• Pre-assembled shelves in multiple configurations• Can include adapter panels for maximum 48 LC, 48 SC, 36 ST or 36 FC terminations• Rubber fiber slotted bracket built-in, plastic splice shelf to protect the fibers• 2 fiber spools built-in for 900µm tight buffered fiber storing • Capable of storing up to 3 meters of 900µm tight buffered fiber per adapter • Snap-in locker design, easy to change adapter panels for various connector patching • Removable front and rear covers for better access to interior of LIU • Removable rubber grommet allows for pre-terminated fiber trunk installation, protects cable and minimizes dust build-up

• Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube

KEY FEATURES

FIBER OPTIC COMPONENTS | LIU FIXED 1U / 2U

D-Link 19-inch Fixed Optical Fiber Interconnection Units are the smaller basic patch panels & cabinets used in interconnecting, cross- connecting, or splicing applications in LANs at a premise location. The LIU (optical fiber interconnecting unit) is modular and suitable for optical cable installation, bare fibers splicing & protection, pigtails storage & management. The number of fibers determines which LIU is appropriate for the application. The D-Link 1U & 2U Series Combination Shelves help you save time & money to manage your cable resources efficiently. By using these shelves to terminate and splice fibers, you can rearrange cabling quickly and keep track of your fiber resources. Efficient fiber management also helps save on maintenance and replacement costs.

SPECIFICATIONS

ORDERING INFORMATION

Parts Material Dimension Remarks

Metal Shelf Alum., 1.2mm Thickness 410x310x43.5mm (DxWxH) 1U, Black or Beige | 2U, Black

Metal Mounting Ear Steel, 2.0mm Thickness 105x36.43.5mm (DxWxH) 2 Pieces, Black or Beige

Splice Tray Plastic 220x89x18mm (DxWxH) 12/24 Fibers, 1 Tray, 2 Trays Max

Cable Plugs Rubber 28mm Diameter For 4 Cable Entries

Adapter Panel Steel, 1.5mm Thickness 175x37mm (WxH) 2 Panels, Black or Beige | 2U - 4 Panels, Black

Product Code Description

NLU-FXXUXXR-06 LIU 6 PORT Rack Mount - Unloaded

NLU-FXXUXXR-12 LIU 12 PORT Rack Mount - Unloaded

NLU-FXXUXXR-24 LIU 24 PORT Rack Mount - Unloaded

NLU-FXXUXXR-48 LIU 48 port Rack Mount Unloaded

NLU-FMSLSCR-12 LIU 12 PORT Rack Mount - Loaded (SC) MM

NLU-FMDLSCR-24 LIU 24 PORT Rack Mount - Loaded (SC) MM

NLU-FMSLLCR-12 LIU 12 PORT Rack Mount - Loaded (LC) MM

Product Code Description

NLU-FMDLLCR-24 LIU 24 PORT Rack Mount - Loaded (LC) MM

NLU-FSSLSCR-12 LIU 12 PORT Rack Mount - Loaded (SC) SM

NLU-FSDLSCR-24 LIU 24 PORT Rack Mount - Loaded (SC) SM

NLU-FSSLLCR-12 LIU 12 PORT Rack Mount - Loaded (LC) SM

NLU-FSDLLCR-24 LIU 24 PORT Rack Mount - Loaded (LC) SM

Page 77: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

77

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• Suitable for interconnect in cables distribution or between cables and optical equipments• Space saving with its compact & small design of enclosure• Front door design is easy for operation & fibers expansion • Can manage both splices and terminations• Can include adapter panels for maximum 24 ports LC/SC and 12 ports ST/FC terminations

• Snap-in locker design, easy to change adapter panels for flexible configuration & easy installation

• Top & bottom cable entry is easy with rubber plug

KEY FEATURES

FIBER OPTIC COMPONENTS | LIU WALL MOUNT

The D-Link Wall Mount LIU is a modular enclosure that provides cross-connect and interconnect capabilities for splicing and terminating fiber cables & FTTH drop cables in fiber access network. It integrates three main functions of fiber splicing, cable winding & storing, and interface management. The enclosure adopts good quality metal sheets & surface electrostatic spray technique, which is offering safety & good endurance performance. It is the ideal design for building & campus networking.

SPECIFICATIONS

ORDERING INFORMATION APPLICATION

NLU-FXXUXXW-06NLU-FXXUXXW-12NLU-FXXUXXW-24

PART CODE

LIU 6 PORT Wall Mount - UnLoadedLIU 12 PORT Wall Mount - UnLoadedLIU 24 PORT Wall Mount - UnLoaded

DESCRIPTION • Optical fiber access network• Local area networks• Fiber to the premises• Small-count splice applications

Parts Material Dimension Remarks

Metal Shelf Alum., 1.2mm Thickness 320x250x30mm (LxWxH) Black, Beige

Splice Tray Plastic 140x102x12.5mm (LxWxH) 12/24 fibers/Tray, 2 trays Max.

Adapter Panel Steel, 1.5mm Thickness 175x37mm (WxH) 1 Panel, Black or Beige

Cable Plug Rubber 28mm Diameter For 4 Cable Entries

Page 78: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

78 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

• 1.2mm steel sheet for strong housing• Slim 1 Unit Mounting Height• Ball bearing slid rails with positive stop• Sliding design is easy to work for patching the connectors • Hinged front panel is easy to be turned over & be fixed by snap-in locker• Front-mounted cable saddles for jumper management• Can manage both splices and terminations• Pre-assembled shelves in multiple configurations• Can include adapter panels for up to 48LC, 48 SC, 36 ST or 36 FC terminations• High density splice tray contains 24 fiber maximum in one tray• Clear plastic cover to protect the fibers• 4 fiber saddles built-in for 900µm tight buffered fiber winding & storing

• Capable of storing up to 3 meters of 900µm tight buffered fiber per adapter

• Snap-in locker design, easy to change adapter panels for various connector patching

• Removable rubber grommet allows for pre-terminated fiber trunk installation, protects cable and minimizes dust build-up

• Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube

KEY FEATURES

FIBER OPTIC COMPONENTS |LIU SLIDING 1U/2U

D-Link 19-inch Sliding Optical Fiber Interconnection Units are the smaller basic patch panel & cabinet used in interconnecting, cross connecting, or splicing applications in LANs at a premise location. The LIU (optical fiber interconnecting unit) is modular and suitable for optical cable installation, bare fibers splicing & protection, pigtails storage & management. The number of fibers determines which LIU is appropriate for the application.

The D-Link 1U Series Combination Shelves help you save time & money to manage your cable resources efficiently. By using these shelves to terminate and splice fibers, you can rearrange cabling quickly and keep track of your fiber resources. Efficient fiber management also helps save on maintenance and replacement costs. The 1U sliding LIU utilize easy glide ball bearing slide rails for smooth pullout & push in with a positive stop feature.

SPECIFICATIONS

ORDERING INFORMATION

Part Code Description

NLU-FXXUXXR-06S LIU 6 PORT Rack Mount-Sliding-Unloaded

NLU-FXXUXXR-12S LIU 12 PORT Rack Mount-Sliding-Unloaded

NLU-FXXUXXR-24S LIU 24 PORT Rack Mount-Sliding-Unloaded

NLU-FXXUXXR-48S LIU 48 PORT Rack Mount-Sliding-Unloaded

NLU-FMSLSCR-12S LIU 12 PORT Rack Mount-Sliding-Unloaded(SC)MM

NLU-FMDLSCR-24S LIU 24 PORT Rack Mount-Sliding-Unloaded(SC)MM

Part Code Description

NLU-FMSLLCR-12S LIU 12 PORT Rack Mount-Sliding-Loaded(LC)MM

NLU-FMDLLCR-24S LIU 24 PORT Rack Mount-Sliding-Loaded(LC)MM

NLU-FSSLSCR-12S LIU 12 PORT Rack Mount-Sliding-Loaded(SC)SM

NLU-FSDLSCR-24S LIU 24 PORT Rack Mount-Sliding-Loaded(SC)SM

NLU-FSSLLCR-12S LIU 12 PORT Rack Mount-Sliding-Loaded(LC)SM

NLU-FSDLLCR-24S LIU 24 PORT Rack Mount-Sliding-Loaded(LC)SM

Page 79: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

79

Cat6

Sol

utio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Copp

er S

olut

ion

Prod

uct A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

sCa

t5e

Solu

tion

Prod

ucts

www.dlinkmea.comwww.dlinkmea.com

• Inner slack storage area ensures minimum bend radius• Inner tray for splice sleeve• Suitable for SC or LC adapters• Compact size: Takes less wall space

DESCRIPTION

SPECIFICATIONS

APPLICATIONS

ORDERING INFORMATION

Size (L*W*H) (mm): 86*86*20 / 100.6*80.6*28.8Adapter Type: SC, Duplex LCNo. of Adapter: 2/4Storage of Fibers: G.657 or G.652 fiber appliedMax. Cable Diameter (mm): 3 – 6No. of Cable Entry: 5 (Up, down, left, right, rear)Splice Method: Fusion Splice (40mm sleeve applied)Colour : WhiteMaterial: Impact Plastic

Widely used in FTTH access Network

NFO-FXDXX02NFO-FXSSC02NFO-FXDLC02NFO-FXDXX04

Blank OutletFibre Optic Micro ODF with 02 Simplex SC/APC AdaptersFiber Optic Micro ODF with 2Nos Duplex LC/APC Adapter4-Port Blank Micro ODF

PART CODE DESCRIPTION

MICRO ODF

Fiber Optic Outlet is used in FTTH indoor application. It enables termination of fiber optic cables within residence and commercial buildings. The bend radius of the individual fibers does not fall below 15mm, thereby minimize the signal transmission losses.

Page 80: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

80 www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

Sol

utio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

t Acc

esso

ries

Fibe

r Opt

ic C

able

sFi

ber O

ptic

Com

pone

nts

APPLICATIONS

• FTTX (FTTP, FTTH, FTTN, FTTC)• Passive Optical Networks (PON)• Local Area Networks (LAN)• Test Equipment• Monitoring system

ORDERING INFORMATION

NFS-FSSSC2-32-APC 2 x 32 PLC Splitter Module with SC/APC Adapters

PART CODE DESCRIPTION

• Quartz substrate integrated waveguard• Good Uniformity and low insertion loss• Low Polaration Dependent Loss• Excellent Environmental Stability• High Reliability• Channel-to-Channel uniformity• Small size

KEY FEATURES

PLC SPLITTER - RACK MOUNT

SPECIFICATIONS

Parameter 1 x 2 1 x 4 1 x 8 1 x 16 1 x 32 1 x 64 2 x 2 2 x 4 2 x 8 2 x 16 2 x 32 2 x 64

Wavelength (nm) 1260-1650

Max. Insertion Loss (dB)

3.8/4.1 7.0/7.4 10.0/10.3 13.5/ 13.7 16.5/ 16.9 21 4.1/4.3 7.3/7.6 10.3/10.5 13.7/ 13.9 16.8/ 17.2 21.5

Max. LossUniformity (dB)

0.6 0.6 0.8 1.2 1.5 2.5 0.8 0.8 1.5 2.0 1.5 2.5

Max. PDL (dB) 0.2 0.2 0.3 0.3 0.3 0.4 0.2 0.2 0.4 0.4 0.4 0.4

Return Loss (dB) ≥50

Directivity (dB) ≥55

Pigtail Length (m) 1.2 (± 0.1), customer specified

Fiber Type Corning SMF-28e, customer specified

OperatingTemperature (˚C)

-40 – +85

Planar Light Circuit (PLC) splitters exhibit uniform signal splitting for FTTH and PON network. It is fabricated using silica optical waveguide technology. Splitters come with SC adapter. It meets GR-1209 and GR-1221 standard for performance and reliability.

Page 81: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Cat5

e So

lutio

n Pr

oduc

ts

CERTIFICATIONS

3/5/2015 DUZX.E350461 ­ Communications Cable

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=DUZX.E350461&ccnshorttitle=Communications+Cable&objid=10820275… 1/1

DUZX.E350461Communications Cable

Page Bottom

Communications Cable

See General Information for Communications Cable

D­LINK (INDIA) LTD E350461KALPATARU SQUARE, 2ND FL, UNIT­24KONDIVITA LANE, OFF ANDHERI KURLA RDANDHERI (EAST)MUMBAI, 400059 INDIA

Type(s) CM, CMR, CMX, CMX Outdoor, CMX Outdoor­CM, CMX Outdoor­CMR

Last Updated on 2014­12­30

Questions? Print this page Terms of Use Page Top

© 2015 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environmentdatabase for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow­Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­UpService. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directorywith permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice inthe following format: "© 2015 UL LLC".

3/12/2015 DUXR.E470881 ­ Communications­, Audio/Video­, Data­ and Other Signaling­circuit Accessories

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=DUXR.E470881&ccnshorttitle=Communications­,+Audio/Video­,+Data­… 1/1

DUXR.E470881Communications­, Audio/Video­, Data­ and Other Signaling­circuit Accessories

Page Bottom

Communications­, Audio/Video­, Data­ and Other Signaling­circuit Accessories

See General Information for Communications­, Audio/Video­, Data­ and Other Signaling­circuit Accessories

D­LINK (INDIA) LTD E470881KALPATARU SQUARE, 2ND FL, UNIT­24KONDIVITA LANE, OFF ANDHERI KURLA RDANDHERI (EAST)MUMBAI, 400059 INDIA

CAT.6 Patch Cord, Model(s) NCB­C6UXR1­Y ($)

CAT.6A Patch Cord, Model(s) NCB­6AUXR1­Y ($)

Keystone jacks, Model(s) NKJ­C6WHI1B21, NKJ­5EWHI1B21, NKJ­6AWHI1B21

($) ­ X can be two or three letters indicating Cable color, and Y represents length of the Patch Cord, Y can be 0 to 10000

Last Updated on 2015­03­04

Questions? Print this page Terms of Use Page Top

© 2015 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environmentdatabase for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow­Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­UpService. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directorywith permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice inthe following format: "© 2015 UL LLC".

3933 US Route 11Cortland, New York 13045 USAPhone Number: (800) 345-3851Fax Number: (607) 758-6637Web: www.intertek.com

Kathy Heath, Program Coordinator

Taipei TWN 114, Taiwan

No. 289, Xinhu 3rd Road

Product Tested:

Continuing compliance to this specification is monitored through production testing, quarterly inspections by Intertek at the production facility and random sample testing.

Approved By:

7/30/2011

3-Connector Channel

ANSI/TIA-568-C.2 Category 6 with the applicable electrical transmission characteristics

Date Verified:

Product(s) Literature May Include:

Applicant:D-Link Corporation

Neihu District

On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the time the tests were carried out.

ETL Verified Certificate of Conformance Number: 100455538CRT-001a

Contact:

Manufacturer:

Verification/Report Number: 100060793CRT-001c

Mr. Joe Chou

8/23/2011Date Revised:

This verification supersedes all previous verifications with the noted Verification/Report number(s) dated before this verification notice.

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

NOTE: This verification is part of the full test report(s) and should be read in conjunction with it.

Antoine Pelletier, Engineer

Standard(s)/Specification:

ETL Verified 3-Connector Channel to ANSI/TIA-568-C.2 Category 6, along with channel illustration, and parts numbers.

Taipei TWN 114, Taiwan

No. 289, Xinhu 3rd RoadD-Link Corporation

Neihu District

Contact: Mr. Joe Chou

Component ID1234567

ManufacturerD-LinkD-LinkD-LinkD-LinkD-LinkD-LinkD-Link

Part NumberNCB-C6UGRYR1-xNPP-C61BLK242NCB-C6UGRYR-xxxNKB-0WHIx2NCB-C6UGRYR1-xNKJ-C6xxx1B21NCB-C6UGRYR1-x

DescriptionPatch CordPatch PanelHorizontal CableMounted BoxPatch CordKeystone JackPatch Cord

3933 US Route 11Cortland, New York 13045 USAPhone Number: (800) 345-3851Fax Number: (607) 758-6637Web: www.intertek.com

John Cash, Associate Engineer

Andheri (East), Mumbai - 400059, India

Unit 24, 2nd Floor, Kalpataru Square

Product Tested:

Continuing compliance to this specification is monitored through production testing, quarterly inspections by Intertek at the production facility and random sample testing.

Approved By:

12/5/2013

Model(s) and or Brand Name: NCB-C6UGRYR-305

4 pair, 23 AWG, UTP, CMR, Non-Plenum Riser, Horizontal (solid) Cable.

ANSI/TIA-568-C.2 and ISO/IEC 11801 Category 6 with the applicable electrical transmission characteristics

Date Verified:

Jacket marking shall include:

Applicant:D-Link (India) Limited

Kondivita Lane, Off Kurla Road

On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the time the tests were carried out.

ETL Verified Certificate of Conformance Number: 101450856CRT-001b

Contact:

Manufacturer:

Verification/Report Number: 3143722CRT-002c

Mr. Raj Jadhav

This verification supersedes all previous verifications with the noted Verification/Report number(s) dated before this verification notice.

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

NOTE: This verification is part of the full test report(s) and should be read in conjunction with it.

Antoine Pelletier, Team Leader

Standard(s)/Specification:

ETL Verified to ANSI/TIA-568-C.2 and ISO/IEC 11801 Category 6.

Andheri (East), Mumbai - 400059, India

Unit 24, 2nd Floor, Kalpataru SquareD-Link (India) Limited

Kondivita Lane, Off Kurla Road

Contact: Mr. Raj Jadhav

81www.dlinkmea.comwww.dlinkmea.com

Page 82: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

The ‘D-Link Certified Cabling Expert’ (DCCE) program has been established with the objective of imparting enhanced knowledge on structured cabling to the engineers & technicians of its System Integrators.

This 2-day DCCE program is conducted by a team specialized in the structured cabling domain and with decades of experience from D-Link, which provides participants with in-depth information on the technical aspects of the subject, evaluates trends for both Copper and Fiber products, and trains them to design, install and conduct post implementation testing of D-Link passive networking components for infrastructure projects.

After the 2-day DCCE program, participants have to undergo an exam, and once certified as DCCE will be in a position to validate projects where-in D-Link Structured Cabling products are implemented with 25-year performance warranty.

D-Link Certified Cabling Expert (DCCE)

82 www.dlinkmea.com

D-Link Certified Cabling Expert

CERTIFICATE

This is to certify that

has successfully undergone the D-Link Certified Cabling Expert Training

held on in

Mr. Prasanna KodolikarPrincipal Trainer

Mr. Gary YangVice President D-Link Middle East, India & AfricaPresident D-Link Middle East, India & Africa

Page 83: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

Technical Services & Support

UAE: +971 4 880 9033 | [email protected]

KSA: +966 1121 70009 | [email protected]

Morocco: +212 700 131 415 | [email protected]

Egypt: +20 2267 38470 | [email protected]

Pakistan: +92 21 3454 8310 | [email protected]

Kuwait: +965 2245 3939 | [email protected]

Qatar: +974 441 43774 | [email protected]

Bahrain: +973 1333 2904 | [email protected]

Oman: +968 2448 0482 | [email protected]

Cyprus: +357 2231 9226 | [email protected]

Nigeria: [email protected]

Place an eTicket

E-Ticket: www.dlinkmea.com/techsupport

Register your products

Product Registration: www.dlinkmea.com/register

At D-Link we take your technical requirements very seriously, and our regional

established technical support centers are happy to help you whenever there is need.

We are just one call away.

83www.dlinkmea.comwww.dlinkmea.com

Page 84: Structured Cabling Solutions · 2018-10-25 · STRUCTURED CABLING A Structured Cabling System (SCS) is an organized way of cabling and installing passive components following a specific

www.dlinkmea.com

Version 1810C

Authorized Partner

D-Link Middle East & Africa Offices

MIDDLE EAST & AFRICA (DUBAI)

P.O. Box 18224 Jebel Ali Free Zone - South Dubai - United Arab Emirates TEL: +971-4-880-9022 FAX: +971-4-880-9069 TECHNICAL SUPPORT: [email protected] +971-4-880-9033 URL: www.dlinkmea.com

KINGDOM OF SAUDI ARABIA

Office #84, Al Khaleej Building Opp. King Fahd Road, Olaya Riyadh, Saudi Arabia TEL: +966-11-217-0008 +966-11-216-5813 TECHNICAL SUPPORT: +966-11-217-0009 EMAIL: [email protected] URL: www.dlinkmea.com

EGYPT

1, Makram Ebeid Street City Light Building - Floor 5 Nasrcity - Cairo, Egypt TEL: +20-2-2352-1593, +20-2-2352-0852 EMAIL: [email protected] URL: www.dlinkmea.com

PAKISTAN

D-147/1 KDA Scheme # 1 Karsaz Road Karachi – Pakistan TEL: +92-21-3454-8158, +92-21-3430-5069 +92-21-3454-8310 E-Mail: [email protected] FAX: +92-21-3437-5727 www.dlinkmea.com

MOROCCO

Sidi Maarouf Bussiness Centre 1100 Bd El Qods Casanearshore 1 Casablanca 20270, Morocco TEL: +212-700-131-415 EMAIL: [email protected] URL: www.dlinkmea.com

NIGERIA

Novel House Plot 3, Otunba Jobi Fele Way Central Business District Alausa, Ikeja Lagos TEL: +234-0-8030-4050-55 E-Mail: [email protected] URL: www.dlinkmea.com

KENYA

Park Suites 3rd Floor, Suite 15 Parklands Road, Parklands Nairobi, Kenya E-Mail: [email protected] URL: www.dlinkmea.com

Cat5

e So

lutio

n Pr

oduc

tsCa

t6 S

olut

ion

Prod

ucts

Cat6

a So

lutio

n Pr

oduc

tsCo

pper

Sol

utio

n Pr

oduc

ts A

cces

sorie

sFi

ber O

ptic

Cab

les

Fibe

r Opt

ic C

ompo

nent

s


Recommended