Share this document with a friend
22
ENGINEERING AND INDUSTRIAL S T U D I E S SERVING DESIGNERS, MANUFACTURERS AND OPERATORS
Transcript

ENGINEER ING AND INDUSTRIAL S T U D I E S SERVING DESIGNERS, MANUFACTURERS AND OPERATORS

Relevant solutions, more than 30 years of experience

PRESENTATION :Aentec is an engineering office created nearly 10 years ago, specia-

lized in the execution and detail study, in the fields of boiler making,

piping and pressure vessels. Here, our expertise ranges from the rea-

lization of drawings to calculation notes according to the main codes

recognized on the market. Our field experience acquired with manu-

facturers enables us to carry out studies that meet the specific needs

of manufacturing as well as operators, which makes all the difference.

ETS engineering, a company founded 33 years ago was integrated

into the group in 2016. This company is specialized in general ins-

tallation, 3D model, piping, steel frame, boiler making. Thanks to its

experience, it has successfully carried out large-scale projects in both

project management and execution.

Our international expansion has led us to establish AENTEC MIDDLE

EAST in the UnitedArab Emirates to meet the needs of the Middle

East and Africa, in large part, by bringing its skills and professiona-

lism.

To date, other offices have been opened, in India, AENTEC INDIA

and in Nigeria, AENTEC AFRICA showing a strong desire to develop

the group in the world.

8 competency centers

GENERAL INSTALLATION

BOILER-MAKING

INDUSTRIAL PIPING

STEEL STRUCTURE

CALCULATION

DIMENSIONAL MEASUREMENTS BY 3D LASER SCANNING

PMII (MODERNISATION PLAN FOR INDUSTRIAL INSTALLATIONS)

PARTNERSHIP :Aentec and ETS engineering are sports partners and a taste for effort

and high standards are values shared by our teams in their daily work.

STORAGE TANK DIMENSIONAL MEASUREMENTS

STB LE HAVRE HBO (Handball Octeville)

HAC FOOTBALL AERIAL SPORTS

PATRICK MALANDAIN ultrarunner

1

2

3

4

5

6

7

8

RALLY DES GAZELLESAICHA

OUR VALUES

• Reliable

• Reactivity

• Availability

• Competitiveness (thanks to our

different locations)

• Trust

• Confidentiality

• Synergy and complementarity

between the different companies

Aentec and ETS

FOLLOW-UP PROTOCOLQUALITY / SECURITY

• Self checking of documents

• Cross-checkings

• Daily backup of data on centra-

lized server

• Internal coordination meeting /

customer

• Project model review / PID review

• Report and follow-up of the deci-

sions for the projects

• Application of HSE reference

documents (MASE and OH-

SAS18001)

TOTAL FRANCE / TOTAL EP / TRAPIL / AIRBUS / LUBRIZOL France / ALKION / EDF / DRESSER RAND

/ EXXON MOBIL / CHEVRON ORONITE / YARA FRANCE / NORGAL / OMNOVA / ECOMOTION / ENDEL

SUEZ / SHMPP / STX-Chantier Atlantique / CIM / PORT AUTONOME DU HAVRE / CARGILL / NESTLE /

ORIL / AGRIANDRE / FOURE LAGADEC / CMP / PONTICELLI / LAB / SOTUMEC / LOCAMA

OUR REFERENCES

Project progress

3D LASER SCAN OF THE INSTALLATION

IMPLANTATION STUDY / FEASIBILITY STUDY

3D CLIENT MODEL REVIEW

EXECUTION STUDY

MONITORING OF PLANNING OF WORK AND PHASING

DELIVERY AS BUILT FILES

THREE-DIMENSIONAL MEASUREMENTS BY 3D LASER SCANNING

SCANNER FARO Focus S 150 PrecisionVersatile, long-range, high-precision scanner

• Type: Laser Scanner Class 1• Scan Speed: High Speed, 976,000 pts / sec• Range: Up to 150m• Fields of acquisition: 300 ° x 360 °• Precision: +/- 1mm• Optional levelling system: biaxial compensation• Applications: Long-range, High density• Operating temperature -20 ° to + 55 °• Photo resolution: 165 megapixels

Processing softwares

• Real Works• Scene• Cyclone modeller• Autocad• Bricscad

OUR FIELD OF EXPERTISE

• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy• Building• Engineering structure• BIM• Heritage conservation• Ship repair• Crime scene and accident

OUR STRENGTHS

• Realization of fast, accurate and true to reality measurements

• National and international mobility• Reactivity• Competitiveness• The quality of the work

provided• Serious• Already more than 10 years of

experience in the integration of the 3D laser scan dimensional measurements in our studies

• Digitization in challenging envi-ronments

INTERNATIONAL WORK ONSHORE AND OFFSHORE

• Martinica• Congo• Gabon• Morocco• Australia• England• United Arab Emirates• India

COMPETENCY CENTER

Dimensional measurements by 3D laser scanning

Martinica wharf

3D wharf model

Point Cloud

Scan on a oil plateform

1

COMPETENCY CENTER

Dimensional measurements by 3d laser scanning

EXAMPLE OF A STUDY CARRIED OUTPoint cloud real view Point Cloud by colour scan position

3D model of the existing site 3D model after study

Mesures taken from the Plublisher

COMPETENCY CENTER

Measurements on offshore siteEXAMPLE OF A STUDYOFFSHORE OIL FIELD - CONGO

Point Cloud

3D model

Scan

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Measurements on offshore site

QUANT. DIAM. SERIE SPEC. MATIEREDESIGNATION

MATERIEL DE FABRICATION

MATERIEL DE MONTAGE

CODE

Oui Non

NonOui

Oui Non

Plaq. d'ident.

Rep. Poinçon

Trait. Therm.

Points Zéro Oui Non

Fluide :Liquide

Materiaux :IIII4.3

Réglementation DESP

IICatégorie de risques :

Inspection :

CHANTIER

ATELIER

Tenant / Aboutissant :

°C

°C

bar

bar

bar

T°C de calcul :

T°C maxi admis. :

Press maxi serv :

Press de calcul :

Press d'épreuve :

Autres :

Ressuage(s)Radio(s)CND :

Trait. Interne :

Trait. Externe :

Trait. thermique :

Groupe de fluides :

Unité :Plan de référence :

NONOUICalcul :

ClasseEpaisseurDiamètreBloc : Section :

DiamNb :Type:

Calorifuge :

DiamNb :Type:

Traçage :Série : GazFluide:

Rev Date Designation Nom Visa

N° ISO :

Resp. chantier :

Affaire N° :Ep

Ep

Ep

Ep

N1 PIPE, SMLS, SCH STD, ASTM A106 GR B3002.8 m 3002 PIPE, SMLS, SCH STD, ASTM A106 GR B2502.9 m3 PIPE, SMLS, SCH STD, ASTM A106 GR B2001.5 m4 TEE RED, SCH STD, ASTM A234 GR WPB300X25015 RED ECC, SCH STD, ASTM A234 GR WPB250X20016 90 LR ELL, SCH STD, ASTM A234 GR WPB25017 90 LR ELL, SCH STD, ASTM A234 GR WPB20038 FLG WELD NECK, 300LB, SCH STD, ASTM A10530029 FLG WELD NECK, 300LB, SCH STD, ASTM A105250210 FLG WELD NECK, 300LB, SCH STD, ASTM A105200211 GASKET, 300LB, 1/8" THK300112 GASKET, 300LB, 1/8" THK250113 GASKET, 300LB, 1/8" THK200114 FLG BLIND, 300LB, ASTM A1053001

8 11

722DN300X250

659

9

9 12

2304

EL +88739

1087

178

DN250X20027mm OFFSET

563

10 13

1141

VOIR SUITEISO 2

1221

DN300X200STUB IN

526

EL +86300

610

1310

EL +87610

626

10

1163

1585

8606

14

1DN300

4

22

6

2 5

3

3

7

7

3

7

3

DN200

1

300300300300300300300300300300300300300

QUANT. DIAM. SERIE SPEC. MATIEREDESIGNATION

MATERIEL DE FABRICATION

MATERIEL DE MONTAGE

CODE

Oui Non

NonOui

Oui Non

Plaq. d'ident.

Rep. Poinçon

Trait. Therm.

Points Zéro Oui Non

Fluide :Liquide

Materiaux :IIII4.3

Réglementation DESP

IICatégorie de risques :

Inspection :

CHANTIER

ATELIER

Tenant / Aboutissant :

°C

°C

bar

bar

bar

T°C de calcul :

T°C maxi admis. :

Press maxi serv :

Press de calcul :

Press d'épreuve :

Autres :

Ressuage(s)Radio(s)CND :

Trait. Interne :

Trait. Externe :

Trait. thermique :

Groupe de fluides :

Unité :Plan de référence :

NONOUICalcul :

ClasseEpaisseurDiamètreBloc : Section :

DiamNb :Type:

Calorifuge :

DiamNb :Type:

Traçage :Série : GazFluide:

Rev Date Designation Nom Visa

N° ISO :

Resp. chantier :

Affaire N° :Ep

Ep

Ep

Ep

2DN200

3

1

4

1

4

1

4

1

4

1

4

1

4

1

4

1DN

250

N1 PIPE, SMLS, SCH STD, ASTM A106 GR B25017.4 m 3002 PIPE, SMLS, SCH STD, ASTM A106 GR B2000.2 m3 RED ECC, SCH STD, ASTM A234 GR WPB250X20014 90 LR ELL, SCH STD, ASTM A234 GR WPB25075 FLG WELD NECK, 300LB, SCH STD, ASTM A10525016 FLG WELD NECK, 300LB, SCH STD, ASTM A10520017 GASKET, 300LB, 1/8" THK2001

VOIR SUITEISO 1

6 7

299

178

DN250X20027mm OFFSET

908EL +88793

3958

EL +92751

7604

965

EL +91786

3917

1098

EL +90688

2922

1459

5

318

300300300300300300

Maquette d’étude

Extraction of a pipe line

Point Cloud

BENEFITS :

• Scaffolding unnecessary• No need any contact with the

installations• Reduced on-site measurement time• Limited number of people

• Comprehensive measurements• Provision of a publisher (Panoramic photo allowing the

taking of measures)• Very short deadlines for the realization of the 3D models

of your installations, for example the time required for this 3D model: - 2 days of on-site measurements - 1 month for the realization of the 3D model

Realization of isometrics from the 3D model

CAD Model

COMPETENCY CENTER

General installation

OUR FIELD OF EXPERTISE• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy• Building• Engineering structure

OUR STRENGTHS• Reliable• Reactivity• Competitiveness• An experience of more

than 30 years• Our employees come from a

variety of backgrounds, a gua-rantee of flexibility that allows us to intervene in most of the sectors of activity that we en-counter in our businesses.

OUR TOOLS• SCANNER LASER 3D• AUTOCAD• BRICSCAD• INVENTOR• SOLID WORKS• CADWORX• ROBOT STRUCTURAL

ANALYSIS• TEKLA• CAESAR II• AUTOPIPE VESSEL (Microprotol)• NX NASTRAN• MS PROJECT

OUR MEANS• 3D Laser Scan Report• A section :

- General installation - Piping - Steel Structure - Boiler making - Calculation

• Using the codes of construction : - CODAP - CODRES - CODETI - DESP 2014 / 68.CE - ASME - API 650 - ASME B31.3

OUR EXPERTISE• Feasibility study• Preleminary draft / Final draft report• Hydraulic calculation• Realization or modification PID• 3D model• 2D / 3D drawings, piping drawings and isometric

ETS has all the skills required to operate in sectors as diverse as the refining industry, petrochemicals, aeronautics, food processing, the environment and industry in general....

These skills enable us to carry out design studies for the installation of equipment and piping in new or existing environments, taking into account technical, environmental and financial constraints.

Thanks to our expertise, at ETS we offer to assist you throughout your project regarding technical assistance and project management.

With more than 30 years of industry experience, we organize and follow each action of the project in order to meet the deadlines and the required quality by managing the interfaces between the various trades.

Pumping - Hydrocarbon storage

2

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

General installation

Installation of a new ship loa-ding arm and modification of the piping network

Estener factory

Instalation of heated product storage

Processing unit of vents

Moving a LPG pumping

Modification of a biofuel wharf

COMPETENCY CENTER

CalculationOUR FIELD OF EXPERTISE

• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy• Building• Engineering structure

OUR TOOLS

• AUTOPIPE VESSEL (Microprotol)• SICAP• CAESAR II• NX NASTRAN • CASTOR CONCEPT• ROBOT STRUCTURAL

ANALYSIS

OUR MEANS

• A team of experienced calcu-lators in the fields of pressure vessels, piping and steel structure

• Specific calculation by finite element analysis for all designs not covered by conventional codes

OURVOCATION• Be the partner of engineering firms• Be the outscourced consulting en-

gineering company for manufacturers• Provide a local service to operators

OUR SERVICES• Preliminary Design (APS)• Creation of DATASHEET• Realization of calculation note of

pressure vessels• Modification of installation• Fatigue calculation• Creep calculation• Vibration calculation• Hydraulic calculation:

- Network dimensioning - Hydraulic loss

• Taking into account external loads: - Snow / wind / earthquake - Nozzle loads - Lifting, handling - Sea and road transportation

OUR PRACTICE OF CALCU-LATION CODES AND ASSO-CIATED REGULATIONS

• French : CODAP Div. 1 and Div. 2 CODETI Div. 1 and Div. 2 CODRES CM66 NFE 32100 COVAP Snow and wind regulations NV 65 rev 2009 Earthquake rules PS 92. Ministerial Order of March 15, 2000

• American : ASME VIII Div.1 et Div.2 ASME B 31.3 API 650 API 653 TEMA EJMA Nozzle loads WRC 107 / 297 UBC 2015

• European : European directive PED2014/68EC EN 13445 EN 1998-1 EN 1991-1-4 Eurocodes 1- 3 - 8 - 9

• English : BS PD 5500 EEMUA 159 BSI CP3

• Australian : AS1210

• German : AD-Merkblätter

• Dutch : Stoomwezen

• Russian : GOST

3

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Calculation

Calculation by finite element analysis of a clamp for offshoreBody flange with toggle bolt

Nozzle loads calculation

Dust collector duct

Flexibility calculation

Tubesheet calculation

COMPETENCY CENTER

Industrial piping

OUR FIELD OF EXPERTISE• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy• Ship repair

OUR STRENGTHS• An experience of more than 30

years• Reactivity• Competitiveness• The quality of work provided• Reliable• Trained staff• Management and administra-

tion of material databases and piping class

• CADWORKS administrator

OUR TOOLS• AUTOCAD• BRICSCAD• CADWORKS• SOLIDWORKS• INVENTOR• TEKLA

OUR MEANS• A piping team that is well versed

in the specifications of piping work and interfaces with various sorts of specialised work.

• Collaboration with our team of calculators

• Expert in the various calculation codes- CODETI- ASME B 31 3

• Finite element analysis• Flexibility / stress calculation• Under-pressure vessels

calculation

OUR EXPERTISE• Complete feasibility study• Preliminary draft / Final draft report• 3D drawings / 3D model • Budget estimate• Supply Specifications

(List of material supply, quantity surveys...)• Technical assistance :

- Enquiry stage - Technical and financial stage

• New installation• Revamping• Skid• Expertise in Modernisation plan of industrial installations• Isometric with bill material

(according to our drawings or your documents)• Automatic isometric extraction according to the customer specifications

Pig launcher installation

4

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Industrial piping

Désignation :

71 Rue Jules SIEGFRIED76600 LE HAVRE

Fax : 02.35.55.80.28Tel : 02.35.55.79.44

00103217 13 ISO

Désignation :

ISO 00113217 03

71 Rue Jules SIEGFRIED76600 LE HAVRE

Fax : 02.35.55.80.28Tel : 02.35.55.79.44

Truck loading station - 3D model

«Carousel» manifold

Pipeline isometric Pipeline - 3D model

Realisation on site

COMPETENCY CENTER

Steel StructureOUR FIELD OF EXPERTISE

• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy• Building• Engineering structure

OUR STRENGTHS

• An experience of more than 30 years

• Reactivity• Competitiveness• The quality of work provided• Reliable• Trained staff

OUR TOOLS

• ROBOT STRUCTURE ANALYSIS

• TEKLA• NX NASTRAN• AUTOCAD• BRICSCAD

OUR MEANS

• A team highly experienced in the specifications of steel structure and interfaces with different trades

• Collaboration with our team of «general installation»

• Expert in the various calculation codes

• Finite element calculation

OUR EXPERTISE• Existing installation expertise• Modelization• Calculation of structure :

- Calculation notes- Analysis of displacement constraints- Lifting calculation- Snow, wind, earthquake calculation - Connnexions calculation- Calculation of the anchor bolts

• 3D Drawings / 3D Models• Realization of a guide drawing• Realization of a manufacturing detailed drawing:

- Tracking sheet- Assembly sheet

• Creation of quantity surveys and lists of material supply• Expert in building codes• Integration of new structure in an existing environment• Budget estimate

Steel structure• Building and industrial installation• Storage warehouse• Racks• Means of access• Superstructure• Skid

5

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Steel Structure

Page :142

CALCUL DES STRUCTURES ACIER ----------------------------------------------------------------------------------------------------------------------------------------

NORME: CM66

TYPE D'ANALYSE: Vérification des familles

----------------------------------------------------------------------------------------------------------------------------------------

FAMILLE: 11 Poutres - HEA180

PIECE: 881 POINT: 1 COORDONNEE: x = 0.00 L = 0.000 m

----------------------------------------------------------------------------------------------------------------------------------------

CHARGEMENTS: Cas de charge décisif: 14 EFF /210/ 1*1.00 + 2*1.00 + 3*1.00 + 4*1.00 + 10*1.75 + 13*0.83 + 6*1.00

----------------------------------------------------------------------------------------------------------------------------------------

MATERIAU: ACIER fy = 23.50 daN/mm2

----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: HEA 180

ht=171.0 mm

bf=180.0 mm Ay=3420.00 mm2 Az=1026.00 mm2 Ax=4525.14 mm2

ea=6.0 mm Iy=25102900.00 mm4 Iz=9246050.00 mm4 Ix=142000.00 mm4

es=9.5 mm Wely=293601.17 mm3 Welz=102733.89 mm3

----------------------------------------------------------------------------------------------------------------------------------------

CONTRAINTES: SigN = -79.51/4525.14 = -0.02 daN/mm2

SigFy = -3361.42/293601.17 = -11.45 daN/mm2

SigFz = -11.99/102733.89 = -0.12 daN/mm2

----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT: z=1.00 B=1.00 D=1.10 Sig D=16.74 daN/mm2

lD_inf=1.600 m C=2.77 kD=1.00

----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE FLAMBEMENT:

en y: en z:

----------------------------------------------------------------------------------------------------------------------------------------

FORMULES DE VERIFICATION: SigN + kD*SigFy + SigFz = -0.02 + 1.00*-11.45 + -0.12 = | -11.58 | < 23.50 daN/mm2 (3.731)

1.54*Tauy = |1.54*-0.00| = |-0.01| < 23.50 daN/mm2 (1.313)

1.54*Tauz = 1.54*4.12 = 6.34 < 23.50 daN/mm2 (1.313)

----------------------------------------------------------------------------------------------------------------------------------------

Profil correct !!!

Agri-Food - coffee grounds extraction line Stairwell

Test of a loading gantry

Truck loading station

Monorail support structure

COMPETENCY CENTER

Boiler-makingOUR FIELD OF EXPERTISE

• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy

OUR STRENGTHS

• An experience of more than 30 years

• Reactivity• Competitiveness• The quality of work provided• Reliable• Trained staff

OUR MEANS

• A team highly experienced in the specifications of Boiler making and interfaces with different trades

• Collaboration with our team of «general installation»

• Expert in the various calculation codes

• Finite element calculation• Under-pressure vessels

calculation

OUR TOOLS

• AUTOCAD• BRICSCAD• SOLIDWORKS• INVENTOR• AUTOPIPE VESSEL (Microprotol)• SICAP• CASTOR CONCEPT• NX NASTRAN

OUR EXPERTISEThanks to our experience of manufacturers, we are able to carry out studies adapted to the needs of manufacturing, as we are aware of the reality of the problems related to it.• DIMENSIONAL MEASUREMENTS BY 3D LASER SCANNING of existing equipment

for modification or construction, just the way it was.• Realization of production drawings

- General arrangement drawing- Detailled drawing

• Realization of calculation notes following codes and regulations associated with each country

• Realization of a guide drawing / data sheet• Boiler equipment study of any size up to 150mm for the shell thickness for high

pressure vessel• Assistance for the quotation of pressure vessel

OUR STUDIES ARE ABOUT• COLUMNS• REACTORS : single or double envelope• HEAT EXCHANGERS : BEM, AES, AET, BKU, BEU, CEU, NEN ...• AEROSCONDERS• MP and HP VESSELS: vertical and horizontal, on a stand, skirt or cradle• STORAGE TANK• SKID• FRAMEWORKS and means of access

Boiler

6

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Boiler makingGeneral arrangement drawing HP vessel Detailled drawing of a self renforcing nozzle Absorption column - Australia

Inside diameter: 4350 mmHeight: 60,000 mm

Material: INOX 304NWeight: 375 tons

Nitric acid processCode: AS1210 + ASME VIII Div.1

Lifting study - Weight 110 tons

Hydraulic Guard - 3D model

Reactor for Indonesia

COMPETENCY CENTER

Storage tanksdimensional measurements

OUR EXPERTISE• Storage tanks study according to API 650 / API 653 / CODRES / EEMUA 159• Verification of roundness, verticality, settlement:

- Outdoor dimensional measurements are used to determine the roundness and verticality of the storage tanks- In addition, interior measurements allow to determine the settlement of the shell and of the bottom

• Calculation of the volumes of the storage tank• Calculation of the retention volumes• Determination of the point of overflow • Determination of the volumes and tables of linearity of the tanks and vertical and

horizontal vessel

OUR FIELD OF EXPERTISE

• Petrochemistry• Refining• Offshore• Agri-Food• Pharmacy

OUR STRENGTHS

• Reliable• Reactivity• International mobility• Competitiveness• An experience of more

than 30 years• Trained staff

OUR TOOLS

• REALWORKS• SCENE• TANKS• AUTOCAD• AUTOPIPE VESSEL (Microprotol)• NX NASTRAN

OUR MEANS

• 3D Laser Scan Report• Competency center :

- Dimensional control- General installation- Calculation- Piping- Boiler making- Steel Structure

• Using the codes of construc-tion :- API 650- CODRES- API 653- EEMUA

Automatic cleaning of the tank and different equipment.Automatic segmentation of the shell, floor, roof, interior equipment.

Tank measurement on stand with scanner Faro Focus S 150. External and internal measurements.

7

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

Storage tanks

Rapport de verticalité Station 1 & Station 5

Station 1

Virole A partir de l'arête

Altitude(m) Tolérance utilisée(m)

Écart(m) Accepté/Refusé

Virole 5 Soudure 6 -0.300 m 8.3752 0.1100 0.0195 ACCEPTÉ

Virole 5 Soudure 5 +0.300 m 7.1112 0.1100 0.0220 ACCEPTÉ Virole 4 Soudure 5 -0.300 m 6.5112 0.1100 0.0228 ACCEPTÉ

Virole 4 Soudure 4 +0.300 m 5.0998 0.1100 0.0223 ACCEPTÉ

Virole 3 Soudure 4 -0.300 m 4.4998 0.1100 0.0210 ACCEPTÉ

Virole 3 Soudure 3 +0.300 m 3.1415 0.1100 0.0159 ACCEPTÉ Virole 2 Soudure 3 -0.300 m 2.5415 0.1100 0.0193 ACCEPTÉ

Virole 2 Soudure 2 +0.300 m 1.1819 0.1100 0.0262 ACCEPTÉ

Virole 1 Soudure 2 -0.300 m 0.5819 0.1100 0.0252 ACCEPTÉ

Virole 1 Soudure 1 +0.300 m -1.2524 0.1100 0.0027 ACCEPTÉ

Station 5 Virole A partir de

l'arête Altitude(m) Tolérance

utilisée(m) Écart(m) Accepté/Refusé

Virole 5 Soudure 6 -0.300 m 8.3752 0.1100 0.0046 ACCEPTÉ Virole 5 Soudure 5 +0.300 m 7.1112 0.1100 0.0049 ACCEPTÉ

Virole 4 Soudure 5 -0.300 m 6.5112 0.1100 0.0017 ACCEPTÉ

Virole 4 Soudure 4 +0.300 m 5.0998 0.1100 -0.0162 ACCEPTÉ

Virole 3 Soudure 4 -0.300 m 4.4998 0.1100 -0.0183 ACCEPTÉ Virole 3 Soudure 3 +0.300 m 3.1415 0.1100 -0.0154 ACCEPTÉ

Virole 2 Soudure 3 -0.300 m 2.5415 0.1100 -0.0122 ACCEPTÉ

Virole 2 Soudure 2 +0.300 m 1.1819 0.1100 -0.0141 ACCEPTÉ

Virole 1 Soudure 2 -0.300 m 0.5819 0.1100 -0.0110 ACCEPTÉ

Virole 1 Soudure 1 +0.300 m -1.2524 0.1100 -0.0025 ACCEPTÉ

Rapport de circularité Virole 1: Soudure 1 +0.300 m

Station Différence de

rayon(m) Accepté/Refusé

0.0381m

1 -0.0104 ACCEPTÉ 2 0.0003 ACCEPTÉ

3 0.0048 ACCEPTÉ

4 -0.0047 ACCEPTÉ

5 -0.0057 ACCEPTÉ 6 -0.0079 ACCEPTÉ

7 0.0007 ACCEPTÉ

8 0.0094 ACCEPTÉ

Distance à la robe(m)

Altitude(m) Altitude depuis la référence(m)

0.0000 -1.5607 0.0098

0.1000 -1.5604 0.0100

0.2000 -1.5570 0.0133 0.3000 -1.5618 0.0085

0.4000 -1.5604 0.0098

0.5000 -1.5591 0.0111

0.6000 -1.5572 0.0128 0.7000 -1.5573 0.0127

0.8000 -1.5581 0.0118

0.9000 -1.5596 0.0103

1.0000 -1.5606 0.0092 1.1000 -1.5622 0.0076

1.2000 -1.5640 0.0056

1.3000 -1.5653 0.0043

1.4000 -1.5657 0.0039

1.5000 -1.5660 0.0035 1.6000 -1.5655 0.0039

1.7000 -1.5662 0.0032

1.8000 -1.5662 0.0031

2.8000 -1.5768 -0.0082 3.8000 -1.5708 -0.0027

4.8000 -1.5662 0.0012

5.3183 -1.5609 0.0061

Station Altitude(m) Affaissement hors-plan(m)

Déflexion hors-plan(m)

Dépasse 0.0103m?

1 -1.5607 0.0047 0.0069 Non 2 -1.5638 0.0010 -0.0021 Non 3 -1.5635 0.0014 0.0058 Non 4 -1.5756 -0.0099 -0.0155 Oui 5 -1.5569 0.0098 0.0156 Oui 6 -1.5691 -0.0017 -0.0066 Non 7 -1.5673 0.0000 0.0035 Non 8 -1.5718 -0.0053 -0.0077 Non

• Determination of the number of verticals and shells courses• Determination of the step for the study of the sagging of the shell and of the

bottom

Calculation of the retention volume with determi-nation of the overflow point

Field of the deformations of the shell

Verticality reportStation 1 & Station 5

Circularity reportFerrule 1: weld 1 +0.300 m

Bottom settlement report Shell settlement reportMaximum possible out of plane deflection (bassed on API 653)

(L².Y.11) / (2.E.H) = 0.0103m

Point of overflow

Rapport de circularité Virole 1: Soudure 1 +0.300 m

Station Différence de

rayon(m) Accepté/Refusé

0.0381m

1 -0.0104 ACCEPTÉ 2 0.0003 ACCEPTÉ

3 0.0048 ACCEPTÉ

4 -0.0047 ACCEPTÉ

5 -0.0057 ACCEPTÉ 6 -0.0079 ACCEPTÉ

7 0.0007 ACCEPTÉ

8 0.0094 ACCEPTÉ

Station Altitude(m) Affaissement hors-plan(m)

Déflexion hors-plan(m)

Dépasse 0.0103m?

1 -1.5607 0.0047 0.0069 Non 2 -1.5638 0.0010 -0.0021 Non 3 -1.5635 0.0014 0.0058 Non 4 -1.5756 -0.0099 -0.0155 Oui 5 -1.5569 0.0098 0.0156 Oui 6 -1.5691 -0.0017 -0.0066 Non 7 -1.5673 0.0000 0.0035 Non 8 -1.5718 -0.0053 -0.0077 Non

COMPETENCY CENTER

PMIIOUR STRENGTHS

• 3D laser scan dimensional measurements

• Creation of a 3D model of the facilities that can be used for studies

• To diagnose possible disorders and find technical solutions to fix it

OUR MEANS

• CND / PV measurement control

• Full implementation of PMII with associated document management

• Plan for inspection and control • Calculation of the minimum

thicknesses• Pipes replacement program• Supporting and framework

analysis

TECHNICAL SOLUTIONS

• 3D model of your site for an inventory of the pipelines and installations

• Calculation of the minimum pipe thicknesses

• Calculation of the boiler equipment

• Calculations of the racks and supports

• Study and technical recommendations

MODERNISATION PLAN OF INDUSTRIAL INSTALLATIONSThe Modernization Plan of Industrial Installations (PMII) initiated at the beginning of 2010 by the French Environment Ministry is implemented by the «arrêté of 4 october 2010».

Under this decree and based upon technical guides, operators will:• Make an accurate inventory of all equipment that present a risk of

pollution• Establish an initial state of these equipments• Develop and implement inspection plans

May we suggest:

Either the full implementation of the PMII

on your site

Or an improvement of the PMII already in place

on your site

N° ligne: 80 CLF 806 A rév Date Modifié Approuvé par

Venant de : Ligne de chargement C3 Allant à : 16" 0 26/02/2014 ETS X-Picton5,50 mm

Pression service/calcul (bar) : 35 bar (s) 35 bar (s) FTemp.service/Calcul (°C) : -45 ° C 50 ° C CL 1285 NADate de mise en service :

Repère L1 L2 L3 R4 C5 T6Diamètre nominal 80 80 80 80 80 80Côte nominale 5,50 5,50 5,50 5,50 5,50 5,50CalorifugéAccessibilitéPoint particulier- 5,50 5,50 5,50 5,50 5,50 5,5024/04/2012 3.3 3.3 3.3 NORGAL07/03/2014 2,70 2,60 2,50 3,10 3,30 6,90 PM2I CONTROL

Epaisseur de remplacement 2,123 2,123 2,123 2,123 2,123 2,123% perte ######## ######## ######## #NOMBRE! ######### ######## #NOMBRE! #NOMBRE! #NOMBRE! ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ########Vit. Corrosion en mm/an ######## ######## ######## #NOMBRE! ######### ######## #NOMBRE! #NOMBRE! #NOMBRE! ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ########

Date de remplacement de la tuyauterie ######## ######## ######## #NOMBRE! ######### ######## #NOMBRE! ######### #NOMBRE! ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ######## ########

Produit :

INSPECTIONS PERIODIQUES AVEC ANALYSE CRITIQUE DES RESULTATS

Valeur exclue LEGENDE

NON ACCESSIBLE-

C3 Epaisseur théoriqueCalorifuge/Frigorifuge

Numéro d'iso

Etablissement

Intitulé

Source E.T.S-PM2I CONTROL PROJET INSPECTION DES LIGNES PM2I-Calcul corrosion-Ligne -80-CLF-0806-A.xlsxDN80

N

1 1

07/03/2014

Classe A 150#

DES NAVIRES TS1 OU CW

ISO 01CL0877

400-CLF-0800-A

VERS TK1

80-CLF-0806-A 01CL1285

100-CL-0700-AISO 01CL1283

DE E01 / DES P02

LIMITE CALO

-45 / +5035b

35bPropane Commercial50

Date:

A B C D E F G H DN valeurmini

L1 3,3 NA NA NA 80 3,3L2 NA 3,3 NA NA 80 3,3L3 3,3 NA NA NA 80 3,3

NA: Non Accessible 24/04/2012

MESURES REALISEES PAR NORGAL

Date:

A B C D E F G H DN valeurmini

L1 3,4 2,7 2,9 2,7 80 2,7L2 2,8 2,6 2,6 2,8 80 2,6L3 2,8 2,5 2,6 2,9 80 2,5R4 3,6 3,4 3,1 3,5 80 3,1C5 3,6 3,6 3,5 3,4 3,5 3,6 3,3 3,8 80 3,3T6 9,0 8,7 8,6 8,5 7,3 6,9 80 6,9

NA: Non Accessible 07/03/2014

OUI

Inspection sheet

Isometric inspection

8

www.aentec-normandie.frwww.ets-industries.fr

COMPETENCY CENTER

PMII

GLOBAL VISION OF THE PROJECTPROCEDURE FOR THE ESTABLISH-MENT OR IMPROVEMENT OF THE PMII

PMII1st stage

Dimensional measurements and 3D model

2nd stageMeasurement of the thicknesses of all submitted pipings and equipments (report - sheet inspection)

3rd stagePlan for the pipeline inspection (lists the anomalies highlighted by the inspection)

4th stageCalculation of the replacement date (critical analysis of the results)

5th stageProgram for replacement and pipes inspection

6th stageFile with the note calculations REPORT OF EQUIPEMENT, PIPES, SUPPORTS

7th stagePhoto files:Inspections of the supports / racks

8sht stageMatrix for calculating the criticality of supports

Rapport 2130608

Date 26/08/2014

Client

Page 1/3

DETAILS DES ELEMENTS CONTROLES

100-ALA-0704-A N° DAO : 01CL1101-1DT96 Plan : 1 sur 12130608Acier carbone

Etat de surface :Température de la pièce : serviceSituation : Isolant: Frigorifuge

MATERIEL UTILISE

Appareil :Marque : Ge Inspection technologie N° série : 11105098Type : DMS GO Date de dernière vérification : 18 Juin 2014

Valable jusqu'au : 18 Juin 2015Palpeur :Marque : GE Inspection N° série : 13H01KY5Type : TC-560 Diamètre du palpeur : 15mm

Fréquence : 5 MHz

Produit de couplant :

Cale d' étalonnage :N° de cale : Pm2iUT002 Nuance : Acier carboneDimensions : 2,5 à 12,5mm

CONSTAT DE VERIFICATION : N°AR16358 5 (GE Inspection technologie)

conditions d'exécution :DT96 (Guide Technique Professionnel Pour l'Inspection des tuyauteries en exploitation)

26/08/2014 UT/PT B02-012574

VISA

PV DE MESURES D' EPAISSEURS PAR ULTRASONS

CONCLUSION

DATE CONTROLEUR CERTIFICATION VISA VERIFICATEUR

Les valeurs sont détaillées en page 3/3.

Ligne :Procédure utilisé :

Affaire N° :Nuance :

Détails de l'inspection visuelle en page 2/3.

Brut Brossé MeuléUsiné

Huile Eau Autre :Graisse Gel de couplage

Peinte

Contrôle interne Contrôle externe

Dimensional measurements of the storage tank

Corroded pipe

LPG Storage

Report of the ultrasound measure

Hydrocarbon Storage

www.aentec-normandie.fr

86 rue Jules Lescene - 76600 Le HavreTEL. +33 (0)9 53 06 23 08

PO BOX 30835 - Ras Al Khaimah - UAETEL. +971 54 400 5239

Plot No: 11, Gupta Layout,Opposite Cricket Stadium, PM Palem,Visakhapatnam, Andhra Pradesh - 530041TEL. +91 9704141177

Plot 327 Akhigbe Road,Trans Amadi Industrial Layout Phase II, Port Harcourt, Rivers state, NigeriaTEL. +234.902.42.00.007

www.ets-industries.fr

LE HAVRE71 rue Jules Siegfried - 76600 Le HavreTEL. +33 (0)2 35 55 79 44

SAVENAYZA des acaciasVoie B – chemin des dames44260 SAVENAYTEL. +33 (0)2 40 03 79 98

Operating areas ETS locations AENTEC locations


Recommended