COVER SHEET PV0.1 SYSTEM SUMMARY SHEET LIST SITE MAP SUNDA REFERENCE DESIGN 1,050KWAC, 1,500VDC REV DATE DESCRIPTION NRECA SUNDA REFERENCE DESIGN 1,050KWAC, 1,500VDC TITLE: PROJECT: 1609 HERITAGE COMMERCE CT WAKE FOREST, NC 27587 POWERSECURESOLAR.COM THIS LINE SHOULD MEASURE ONE INCH DATE: SHEET: 04.06.2017 CONFIDENTIAL & PROPRIETARY PRELIMINARY NOT FOR CONSTRUCTION OF 18 ELECTRICAL PV0.1 COVER SHEET PV0.2 GENERAL NOTES AND SYMBOLS PV1.0 SINGLE LINE DIAGRAM PV1.1 PV SCHEDULES PV1.2 PV LABELS PV2.0 SITE PLAN - ARRAY LAYOUT PV2.1 SITE PLAN - FENCE LAYOUT PV2.2 SITE PLAN - MEDIUM VOLTAGE ROUTING PV2.3 SITE PLAN - COMBINER LAYOUT PV2.4 SITE PLAN - DC FEEDER ROUTING PV2.5 SITE PLAN - AC AND COMMUNICATION FEEDER ROUTING PV2.6 SITE PLAN - ARRAY GROUNDING PV3.0 PARTIAL PLAN - STRINGING LAYOUT NORTH PV3.1 PARTIAL PLAN - STRINGING LAYOUT SOUTH PV4.0 PARTIAL PLAN - EQUIPMENT PAD DIMENSIONS PV4.1 PARTIAL PLAN - EQUIPMENT PAD AC AND COMMUNICATION FEEDER ROUTING PV4.2 PARTIAL PLAN - EQUIPMENT PAD GROUNDING PV5.0 FENCE GROUNDING DETAIL 1 AC SYSTEM SIZE: 1,050.0 KW AC DC SYSTEM SIZE: 1,474.2 KW DC STRING SIZE: 30 STRING COUNT: 156 INVERTER: (1) POWER ELECTRONICS HEC-USFS1050CU15 DC VOLTAGE: 1,500V AC VOLTAGE: 565V, 3ɸ IC VOLTAGE: 12,470V, 3ɸ ARRAY AZIMUTH: 180° ARRAY TILT: 25°
Transcript

COVE

R SH

EET

PV0.1

SYSTEM SUMMARY

SHEET LIST

SITE MAP

SUNDA REFERENCE DESIGN1,050KWAC, 1,500VDC

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

ELECTRICALPV0.1 COVER SHEETPV0.2 GENERAL NOTES AND SYMBOLSPV1.0 SINGLE LINE DIAGRAMPV1.1 PV SCHEDULESPV1.2 PV LABELSPV2.0 SITE PLAN - ARRAY LAYOUTPV2.1 SITE PLAN - FENCE LAYOUTPV2.2 SITE PLAN - MEDIUM VOLTAGE ROUTINGPV2.3 SITE PLAN - COMBINER LAYOUTPV2.4 SITE PLAN - DC FEEDER ROUTINGPV2.5 SITE PLAN - AC AND COMMUNICATION FEEDER ROUTINGPV2.6 SITE PLAN - ARRAY GROUNDINGPV3.0 PARTIAL PLAN - STRINGING LAYOUT NORTHPV3.1 PARTIAL PLAN - STRINGING LAYOUT SOUTHPV4.0 PARTIAL PLAN - EQUIPMENT PAD DIMENSIONSPV4.1 PARTIAL PLAN - EQUIPMENT PAD AC AND COMMUNICATION FEEDER ROUTINGPV4.2 PARTIAL PLAN - EQUIPMENT PAD GROUNDINGPV5.0 FENCE GROUNDING DETAIL

1

AC SYSTEM SIZE: 1,050.0 KW ACDC SYSTEM SIZE: 1,474.2 KW DCSTRING SIZE: 30STRING COUNT: 156INVERTER: (1) POWER ELECTRONICS

HEC-USFS1050CU15DC VOLTAGE: 1,500VAC VOLTAGE: 565V, 3ɸIC VOLTAGE: 12,470V, 3ɸARRAY AZIMUTH: 180°ARRAY TILT: 25°

PV0.2

A AMPS

AC ALTERNATING CURRENT

AL ALUMINUM

ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING

ENGINEERS

C CELSIUS

CT CURRENT TRANSFORMER

CU COPPER

DB DRY BULB

DC DIRECT CURRENT

DIA DIAMETER

DISC DISCONNECT

DWG DRAWING

EGC EQUIPMENT GROUNDING CONDUCTOR

EMT ELECTRICAL METALLIC TUBING

ETL ELECTRICAL TESTING LABS

GALV GALVANIZED

GEC GROUNDING ELECTRODE CONDUCTOR

GFI GROUND FAULT INTERRUPTER

GND GROUND

IMC INTERMEDIATE METALLIC CONDUIT

IMP MAXIMUM POWER CURRENT

INV INVERTER

ISC SHORT CIRCUIT CURRENT

KW KILOWATT

KV KILOVOLT

KA KILOVOLT AMPS

KVM KEYBOARD, VIDEO, MOUSE

LFMC LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT

LFNC LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT

MAX MAXIMUM

MCB MAIN CIRCUIT BREAKER

MIN MINIMUM

MLO MAIN LUG ONLY

MPP MAXIMUM POWER POINT

MV MEDIUM VOLTAGE

NEC NATIONAL ELECTRIC CODE

NEG NEGATIVE

NEU NEUTRAL

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NRTL NATIONALLY RECOGNIZED TESTING LABORATORY

OCPD OVER CURRENT PROTECTION DEVICE

PC PERSONAL COMPUTER

PCC POINT OF COMMON COUPLING

PLC PROGRAMMABLE LOGIC CONTROLLER

POS POSITIVE

PT POTENTIAL TRANSFORMER

PV PHOTOVOLTAIC

PVC POLYVINYL CHLORIDE

RMC RIGID METALLIC CONDUIT

RTU REMOTE TERMINAL UNIT

SCADA SUPERVISORY CONTROL AND DATA ACQUISITION

SCH SCHEDULE

STC STANDARD TEST CONDITIONS

TEMP TEMPERATURE

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLT/VOLTS

VAC VOLTS AC

VDC VOLTS DC

VMP MAXIMUM POWER VOLTAGE

VOC OPEN CIRCUIT VOLTAGE

XFMR TRANSFORMER

1. THE CONTRACTOR IS RESPONSIBLE FOR MEETING ALL OSHA REGULATIONS AND SAFETY PRECAUTIONS ON SITE. THE ENGINEER IS NOT RESPONSIBLE FORSPECIFIC WORKING HAZARDS.

2. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR READING AND UNDERSTANDING ALL EQUIPMENT MANUALS AND DRAWINGS PRIOR TO INSTALLING ANDENERGIZING EQUIPMENT.

3. ALL SYSTEM COMPONENTS SHALL BE LISTED BY A THIRD PARTY TESTING AGENCY (UL, NRTL, ETL, ETC.). ALL EQUIPMENT SHALL HAVE A MINIMUM RATING OFNEMA 3R UNLESS LOCATED INDOORS.

4. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A CERTIFIED ELECTRICIAN AND APPRENTICES UNDER THE SUPERVISION OF A LICENSED ELECTRICALCONTRACTOR.

5. PV STRINGS SHALL BE CONNECTED AND LABELED AS DETAILED IN THE DRAWING SET.

6. THE SYSTEM SHALL BE INSTALLED PER NEC 2014 AND SHALL ADHERE TO ALL LOCAL CODES AND STANDARDS.

7. THE PV SYSTEM SHALL BE GROUNDED AND BONDED PER NEC ARTICLE 690 SECTION V AND ARTICLE 250. ANY DEVIATIONS FROM THE DRAWINGS SET WILLNEED TO BE APPROVED BY THE ENGINEER.

8. SYSTEM SIGNAGE SHALL BE INSTALLED AND LABELED PER NEC ARTICLE 690 SECTION VI.

9. WORKING CLEARANCES AROUND ALL EQUIPMENT SHALL CONFORM TO NEC 110.26.

10. ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 3 OF THE NEC.

11. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER PRIOR TO MAKING ANY CHANGES. APPROVED CHANGES SHALLREQUIRE A DRAWING REVISION TO MAINTAIN VERSION CONTROL.

12. ACTUAL LOCATION OF OVERHEAD AND UNDERGROUND UTILITIES SHALL BE FIELD VERIFIED AND DOCUMENTED PRIOR TO THE EXECUTION OF ANY WORK.THE ENGINEER OF RECORD SHALL BE NOTIFIED OF ANY DISCREPANCIES TO EXISTING CONDITIONS.

13. ALL CONDUCTORS AND EQUIPMENT SHALL BE CONSIDERED "ENERGIZED" UNLESS CHECKED, AND CHECKED AGAIN. LOCKOUT - TAGOUT PROCEDURES SHALLBE EMPLOYED BEFORE ANY WORK IS DONE ON ELECTRICAL EQUIPMENT.

14. THE CONTRACTOR SHALL MAKE AN EFFORT TO CAUSE AS LITTLE DISTURBANCE AS POSSIBLE AND PROTECT THE NATURAL ENVIRONMENT AND RESOURCESOF THE FACILITY DURING THE COURSE OF THE WORK. ALL DISTURBED AREAS SHALL BE RETURNED TO THEIR PRE-CONSTRUCTION STATE OR BETTER. AREASWHICH ARE SEEDED OR SODDED WITH ESTABLISHED GRASS SHALL BE SEEDED AS SOON AS POSSIBLE AFTER COMPLETION OF THE WORK IN THAT AREA.

15. THE CONDUIT LAYOUT DEPICTED IN THE DRAWING SET IS FOR DIAGRAMMATIC PURPOSES ONLY UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ROUTECONDUIT TO BEST SUIT SITE CONDITIONS AND PROVIDE ACCURATE AS-BUILTS.

16. CONNECTORS, TERMINATIONS AND EQUIPMENT HARDWARE SHALL BE TORQUED PER DEVICE LISTING OR INSTALLATION DOCUMENTATION.

17. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ON THE DRAWINGS INCLUDING EXISTING STRUCTURES. THE ENGINEER SHALL BE NOTIFIED OFANY DISCREPANCIES IN THE DRAWINGS AND/OR EXISTING SITE CONDITIONS.

18. DC VOLTAGE IS ALWAYS PRESENT FROM THE ARRAY DURING DAYLIGHT HOURS. THERE IS A POTENTIAL FOR VOLTAGE TO BE PRESENT AT THE TERMINALS OFTHE DC DISCONNECT, COMBINER BOX AND AT THE DC TERMINALS ON THE INVERTER. ALL PERSONNEL SHOULD BE NOTIFIED OF THIS POTENTIAL HAZARDAND SHOULD TAKE PRECAUTIONS TO PREVENT ACCIDENTAL SHOCK OR INJURY.

19. ALL EQUIPMENT SHALL BE MOUNTED PER MANUFACTURER'S SPECIFICATIONS.

20. THE CONTRACTOR SHALL SUPPLY EQUIPMENT/MATERIAL SUBMITTALS PRIOR TO ORDERING. APPROVAL BY POWERSECURE SOLAR FOR ALL EQUIPMENT ISMANDATORY.

ABBREVIATIONS SYMBOLSGENERAL NOTES

GEN

ERAL

NO

TES

AND

SYM

BOLS

DETAIL TAGXXX-X

#

A

#

R#

EQUIPMENT TAG

FEEDER TAG

KEYED NOTE TAG

REVISION TAG

MODULE

COMBINER

CONTACTOR RECOMBINER

INVERTER

METER

FUSE

CIRCUIT BREAKER

THREE-WINDING TRANSFORMER

TWO-WINDING TRANSFORMER

FUSED DISCONNECT

SWITCH

FUSED SWITCH

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

XXXA

XXXA

X#XXXA

XXXA

XXXA

LA

15A

15A

15A

X#

RATIO

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 182

AutoCAD SHX Text
M

SPD

LA

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

SINGLE LINE DIAGRAMSCALE: NONE1

GENERAL NOTES:

1. PROVIDE LABELS TO EACH INCOMING CIRCUIT IN THE INVERTER.

2. PROVIDE IRREVERSIBLE BONDS AT ALL GROUNDING ELECTRODE CONDUCTORS.

LINE TYPE LEGEND:

DC FEEDERS

AC FEEDERS

MEDIUM VOLTAGE FEEDER

EQUIPMENT

MODULES

PROVIDED BY MANUFACTURE/ OTHERS

COMMUNICATIONS

SIN

GLE

LIN

E DI

AGRA

M

PV1.0

ARRAY156 STRINGS OF 30 MODULES

MODULE, TYP OF 4,6801

SYSTEM SUMMARY

AC SYSTEM SIZE: 1,050.0 KW ACDC SYSTEM SIZE: 1,474.2 KW DCSTRING SIZE: 30STRING COUNT: 156INVERTER: (1) POWER ELECTRONICS

HEC-USFS1050CU15DC VOLTAGE: 1,500VAC VOLTAGE: 565V, 3ɸIC VOLTAGE: 12,470V, 3ɸARRAY AZIMUTH: 180°ARRAY TILT: 25°

MV-TRANSFORMER1050KVA12.47/7.2KV PRIMARY,565V SEC

AUXILIARY DISCONNECT30A FRAME, 15A FUSENEMA 3R

AUX TRANSFORMER5KVA565V PRIMARY240/120V SECONDARY

AUXILIARY POWER PANEL100A BUS, 30A MCB240/120V, 1ɸ,3WIRE, NEMA 3R

16

MV FUSED SWITCHN.C.

MV SWITCH N.C.

CONNECTED TO UTILITY

A

3

20A

,1P

30A

,2P

A1

A2

A3

A4

A5

A6

28 STRINGS OF 30 MODULES

28 STRINGS OF 30 MODULES

28 STRINGS OF 30 MODULES

24 STRINGS OF 30 MODULES

24 STRINGS OF 30 MODULES

24 STRINGS OF 30 MODULES

2000A

2

2

2

3

3

3

4

5

20A

,1P

20A

,1P

20A

,2P

INVERTER

DC CABINET

6

7

8

9

10

1112

13

14

15

B

C

D

D

I

H

EE

F

G

I

J

PV MONITORING SYSTEM

PV METEOROLOGICALSTATION

1500:5

5:1

AutoCAD SHX Text
M

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

PV S

CHED

ULE

S

PV1.1

4

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

PV L

ABEL

S

PV1.2

6

INVERTER

PV PRODUCTION MONITORING SYSTEM

WHITE LETTERING ON BLACK BACKGROUND. TYPICAL OF 1

WHITE LETTERING ON BLACK BACKGROUND.TYPICAL OF 1

TRANSFORMERWHITE LETTERING ON BLACK BACKGROUND. TYPICAL OF 1

PV SERVICE

WHITE LETTERING ON RED BACKGROUND

VOLTAGE: XXX V

AVAILABLE FAULT CURRENT XXX A

CALCULATED: XX/XX/XXXX

OCPD AIC RATING XXX,XXX A

12,470VAC WIREA PHASE BROWNB PHASE ORANGEC PHASE YELLOWNEUTRAL WHITE OR GRAYGROUND GREEN OR BARE

WHITE LETTERING ON BLACK BACKGROUNDPROVIDE WARNING SIGNAGE AT EACH JUNCTION BOX OR ANY OTHERDEVICE WHERE ENERGIZE THAT CONTAINS 12470VAC WIRE.

AC OUTPUT CURRENT 1,285 A

NOMINAL AC VOLTAGE 565 V

DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOADSIDE MAY BE ENERGIZED IN THE OPEN POSITION.

WHITE LETTERING ON RED BACKGROUNDTYPICAL OF 1.

INVERTER AC OUTPUT ANDDISCONNECT

WARNINGTHIS EQUIPMENT IS FED BY MULTIPLE SOURCES

(UTILITY AND PHOTOVOLTAIC)

28 STRINGSRATED MPP CURRENT 235.20 A

RATED MPP VOLTAGE 1,125.0 V

MAX SYSTEM VOLTAGE 1,492.34 V

MAX CIRCUIT CURRENT 312.55 A

WARNINGINTERNAL WIRING MAY BE ENERGIZED AT ANY TIME.

DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOADSIDE MAY BE ENERGIZED IN THE OPEN POSITION.

WHITE LETTERING ON RED BACKGROUNDTYPICAL OF 3: A1-A3

PHOTOVOLTAIC DC COMBINER BOX

XX

5.0KVA AUXILIARYPOWER TRANSFORMER

565:240/120V, 1φWHITE LETTERING ON BLACK BACKGROUND

AUXILIARY POWER PANEL240/120V, 1φ

100A BUS, 30A MCBWHITE LETTERING ON BLACK BACKGROUND

PHOTOVOLTAIC POWERSOURCE

WHITE LETTERING ON RED REFLECTIVE BACKGROUND. TEXT SHALL BE AMINIMUM OF 3/8". THIS LABEL IS REQUIRED ON EXPOSED RACEWAY, CABLETRAY, ENCLOSURES AND CONDUIT BODIES CONTAINING PHOTOVOLTAICCIRCUITS. SPACING AND LOCATION OF LABEL AS SPECIFIED PER NEC690.31(G)(3) & (4).

1500VDC WIRE

WHITE LETTERING ON BLACK BACKGROUNDPROVIDE WARNING SIGNAGE AT EACH JUNCTION BOX, COMBINER BOX,DISCONNECT, AND ANY OTHER DEVICE WHERE ENERGIZE THAT CONTAINS1500VDC WIRE.

POSITIVE BLACKNEGATIVE WHITEGROUND GREEN OR BARE

120/240VAC WIREL1 BLACKL2 REDNEUTRAL WHITE OR GRAYGROUND GREEN OR BARE

WHITE LETTERING ON BLACK BACKGROUNDPROVIDE WARNING SIGNAGE AT EACH JUNCTION BOX OR ANY OTHERDEVICE WHERE ENERGIZE THAT CONTAINS 120/240VAC WIRE.

565VAC WIREA PHASE BROWNB PHASE ORANGEC PHASE YELLOWGROUND GREEN OR BARE

WHITE LETTERING ON BLACK BACKGROUNDPROVIDE WARNING SIGNAGE AT EACH JUNCTION BOX OR ANY OTHERDEVICE WHERE ENERGIZE THAT CONTAINS 360VAC WIRE.

WHITE LETTERING ON BLACK BACKGROUND.

AUXILIARY POWER DISCONNECTMV FUSED SWITCHWHITE LETTERING ON BLACK BACKGROUND. TYPICAL OF 1

PV PRODUCTIONMETEOROLOGICAL STATION

WHITE LETTERING ON BLACK BACKGROUND. TYPICAL OF 1

PV PRODUCTIONMETER

24 STRINGSRATED MPP CURRENT 201.60 A

RATED MPP VOLTAGE 1,125.0 V

MAX SYSTEM VOLTAGE 1,492.34 V

MAX CIRCUIT CURRENT 267.90 A

WHITE LETTERING ON RED BACKGROUNDTYPICAL OF 3: A4-A6

PHOTOVOLTAIC DC COMBINER BOX

XX

28 STRINGSRATED MPP CURRENT 235.20 A

RATED MPP VOLTAGE 1,125.0 V

MAX SYSTEM VOLTAGE 1,492.34 V

MAX CIRCUIT CURRENT 312.55 A

WHITE LETTERING ON RED BACKGROUNDTYPICAL OF 3: DC RECOMBINER A1-A3

INVERTER DC INPUT

XX

24 STRINGSRATED MPP CURRENT 201.60 A

RATED MPP VOLTAGE 1,125.0 V

MAX SYSTEM VOLTAGE 1,492.34 V

MAX CIRCUIT CURRENT 267.90 A

WHITE LETTERING ON RED BACKGROUNDTYPICAL OF 3: DC RECOMBINER A4-A6

INVERTER DC INPUT

XX

WHITE LETTERING ON BLACK BACKGROUND.TYPICAL OF 1

DC CABINETWHITE LETTERING ON BLACK BACKGROUND. TYPICAL OF 1

! WARNINGAPPROPRIATE PPE REQUIRED

ARC FLASH AND SHOCK HAZARD

XXX cal/cm2 Incident Energy at

XXX in Working Distance

XXX in Arc Flash Boundary

XXX kV AC System Voltage

XXX Glove Class

X ft X in Limited Approach Boundary

X ft X in Restricted Approach Boundary

XXX Equipment Label

Arc Flash Study Performed on XX/XX/XXXX

! DANGERNO SAFE PPE EXISTS

ARC FLASH AND SHOCK HAZARD

XXX cal/cm2 Incident Energy at

XXX in Working Distance

XXX in Arc Flash Boundary

XXX kV AC System Voltage

XXX Glove Class

X ft X in Limited Approach Boundary

X ft X in Restricted Approach Boundary

XXX Equipment Label

Arc Flash Study Performed on XX/XX/XXXX

WARNING TEXT SHALL BE BLACK LETTERING ONORANGE BACKGROUND. OTHER TEXT SHALL BEBLACK LETTERING ON WHITE BACKGROUND.TYPICAL OF XX. PROVIDE LABEL ON XX.

DANGER TEXT SHALL BE BLACK LETTERING ONRED BACKGROUND. OTHER TEXT SHALL BEBLACK LETTERING ON WHITE BACKGROUND.TYPICAL OF XX. PROVIDE LABEL ON XX.

IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WARNING: ELECTRIC SHOCK HAZARD

WARNINGINTERNAL WIRING MAY BE ENERGIZED AT ANY TIME.

DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOADSIDE MAY BE ENERGIZED IN THE OPEN POSITION.

IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WARNING: ELECTRIC SHOCK HAZARD

WARNINGINTERNAL WIRING MAY BE ENERGIZED AT ANY TIME.

DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOADSIDE MAY BE ENERGIZED IN THE OPEN POSITION.

IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WARNING: ELECTRIC SHOCK HAZARD

WARNINGINTERNAL WIRING MAY BE ENERGIZED AT ANY TIME.

DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOADSIDE MAY BE ENERGIZED IN THE OPEN POSITION.

IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WARNING: ELECTRIC SHOCK HAZARD

WARNING: ELECTRIC SHOCK HAZARD

IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WARNING: ELECTRIC SHOCK HAZARDIF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED

CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.

WHITE LETTERING ON RED BACKGROUND.PROVIDE LABEL ON PV METER, BREAKER...690.5(C)

WARNING: ELECTRIC SHOCK HAZARD

WARNING: ELECTRIC SHOCK HAZARD

WARNING: ELECTRIC SHOCK HAZARD

WARNING: ELECTRIC SHOCK HAZARD

WARNING: ELECTRIC SHOCK HAZARD

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

ARRA

Y LA

YOU

T

PV2.0

1PV4.0

1PV4.1

1PV4.2

SCALE: 1/32"=1'-0"SITE PLAN - ARRAY LAYOUT1

PV MODULE (TYPICAL OF 4,680)SECURITY FENCE

EQUIPMENT PADTRANSFORMER

POLE MOUNTED COORDINATED SWITCH

BACK OF MODULE TEMPERATURE SENSOR

24' VEHICLE ACCESS GATE

4' PEDESTRIAN ACCESS GATE

CONSTRUCTION LAY DOWN AREA

GENERAL NOTES:

1. REFER TO SINGLE LINE DIAGRAM ON PV1.0 FOR SPECIFICATIONS.

2. REFER TO EQUIPMENT AND FEEDER SCHEDULES ON PV1.1 FOR SPECIFICATIONS.

3. PROVIDE RACKING SYSTEM AT 25° TILT. RACKING SYSTEM SHALL BE A PIER DRIVEN SYSTEM. EACH RACKINGSECTION SHALL CONTAIN 2 MODULES HIGH IN PORTRAIT. HORIZONTAL DISTANCE BETWEEN RACK SECTIONSHALL BE SPECIFIED BY MANUFACTURER. THE RACKING SYSTEM SHALL BE UL LISTED FOR GROUNDINGCONTINUITY. COMPONENTS WITHIN THE RACKING SYSTEM SHALL FORM AN ELECTRICALLY BONDED UNIT ANDWILL REQUIRE ADDITIONAL BONDING FROM ONE INDIVIDUAL RACK SECTION TO ADJACENT SECTIONS. REFERTO MANUFACTURER PROVIDED DOCUMENTATION.

4. SOURCE CIRCUIT CONDUCTORS SHALL BE ROUTED ALONG INTEGRATED WIRE MANAGEMENT TRAY PROVIDEDBY MANUFACTURERE OR BELOW GRADE.

UTILITY PROVIDED POLE, POINT OF DEMARCATION

MEDIUM VOLTAGE SWITCH

6

25'-6"

13'-8 3/8"

DISCONNECT COMBINER (TYPICAL OF 6)

20'-0" MINIMUMTYPICAL

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

FEN

CE L

AYO

UT

PV2.1SCALE: 1/32"=1'-0"SITE PLAN - FENCE LAYOUT1

SECURITY FENCE

24' VEHICLE ACCESS GATE

4' PEDESTRIAN ACCESS GATE

GENERAL NOTES:

1. TOTAL FENCE LENGTH IS APPROXIMATELY 2,520 FEET.

2. FENCE SHALL BE 6'-0" TALL TOPPED WITH 3 STRING BARBED WIRE NO LESS THAN 12" IN HEIGHT. OVERALLHEIGHT OF 7'-0" MINIMUM PER NEC110.31.

3. ONE PERMANENT VEHICLE ENTRANCE GATE, 24' MINIMUM IN WIDTH, LOCATED AS SHOWN.

4. ONE PERMANENT PEDESTRIAN ENTRANCE GATE, 4' MINIMUM IN WIDTH, LOCATED AS SHOWN.

5. REFER TO FENCE GROUNDING DETAIL ON PV5.0.

553'-5 1/2"

702'-3"

553'-5 1/2"

100'-0"

7

100'-0"273'-0 5/8"

24'-0"

8'-0"

4'-0"

252'-9"

20'-0"

20'-0"

20'-0"

20'-0"

20'-0"

Aɸ, PV OUTPUT

Bɸ, PV OUTPUT

Cɸ, PV OUTPUT

Aɸ, MEDIUM VOLTAGE

Bɸ, MEDIUM VOLTAGE

Cɸ, MEDIUM VOLTAGE

NEU, MEDIUM VOLTAGEHo Xo

STRAP TO TANK ANDCONNECTION TO PAD

NEUTRAL

STRAP TO TANK ANDCONNECTION TO PADNEUTRAL

GROUND PAD GROUND PAD

TO EQUIPMENT PADGROUND RING

GROUND ROD, PER NEC250.24(A)(2)

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

MED

IUM

VO

LTAG

E RO

UTI

NG

PV2.2SCALE: 1/32"=1'-0"SITE PLAN - MEDIUM VOLTAGE ROUTING1

GROUND MOUNTED MEDIUM VOLTAGE SWITCH

CONTRACTOR PROVIDED POLE MOUNTED SWITCH

MEDIUM VOLTAGE TRANSFORMER

LINE TYPE LEGEND:

MV FEEDERS

FEEDERS/EQUIPMENTPROVIDED BY OTHERS

UTILITY NEUTRAL

NEW EQUIPMENT

GROUNDING CONDUCTOR

SCALE: NTSMEDIUM VOLTAGE INTERCONNECTION DETAIL2

SCALE: NTSMEDIUM VOLTAGE TRANSFORMER DETAIL3

D D

L

UTILITY OWNEDMETER

UTILITY OWNEDCT AND PT

UTILITY OWNED POLE,POINT OF INTERCONNECTION

D

MEDIUM VOLTAGE TRANSFORMER

GROUND MOUNTED MEDIUM VOLTAGE SWITCH

CONTRACTOR PROVIDED POLE MOUNTED SWITCH

UTILITY OWNED POLE, POINT OF INTERCONNECTION

ALL MEDIUM VOLTAGE SHALL BE ROUTED BELOW GRADE TO POLE

GENERAL NOTES:

1. REFER TO SINGLE LINE DIAGRAM ON PV1.0 FOR SPECIFICATIONS.

2. REFER TO EQUIPMENT AND FEEDER SCHEDULES ON PV1.1 FOR SPECIFICATIONS.

L

L

L

8

FROM EACH CONCENTRIC NEUTRAL

D

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

COM

BIN

ER L

AYO

UT

PV2.3

SCALE: 1/32"=1'-0"SITE PLAN - COMBINER LAYOUT1

GENERAL NOTES:

1. REFER TO EQUIPMENT SCHEDULE ON PV1.1 AND SINGLE LINE DIAGRAM ON PV1.0 FOR SPECIFICATIONS.

COMBINER A1

9

COMBINER A2

COMBINER A3

COMBINER A4

COMBINER A5

COMBINER A6

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

DC F

EEDE

R RO

UTI

NG

PV2.4SCALE: 1/32"=1'-0"SITE PLAN - DC FEEDER ROUTING1

GENERAL NOTES:

1. REFER TO EQUIPMENT SCHEDULE AND SINGLE LINE DIAGRAM FOR SPECIFICATIONS.

2. ALL UNDERGROUND RACEWAY SHALL BE SCHEDULE 40 PVC. TRANSITIONS BELOW TO ABOVE GRADE SHALL BEPER CONDUIT STUB UP DETAIL.

3. FOR TRENCHES 24" WIDE AND LESS, ONLY ONE RUN OF MAGNETIC ELECTRICAL WARNING TAPE SHALL BEREQUIRED PER DETAIL 3.

4. FOR TRENCHES WIDER THAN 24" ONE PIECE OF TAPE SHALL BE LOCATED AT EACH SIDE OF THE TRENCH WITHADDITIONAL RUNS PROVIDED AS NECESSARY. THE MAXIMUM DISTANCE BETWEEN TAPE RUNS SHALL BE 24" ONCENTER.

5. TRENCH BOTTOMS: EXCAVATE TRENCHES 3" DEEPER THAN BOTTOM OF PIPE ELEVATION TO ALLOW FORBEDDING COURSE. HAND EXCAVATE FOR BELL OF PIPE. EXCAVATE TRENCHES 3" DEEPER THAN ELEVATIONREQUIRED IN ROCK OR OTHER UNYIELDING BEARING MATERIAL TO ALLOW BEDDING COURSE.

6. ALL BACKFILL SHOULD BE FREE OF MATERIALS THAT MAY DAMAGE THE CONDUIT OR CABLE SYSTEM. BACKFILLWITHIN 150 MM (6 IN) OF THE CONDUIT OR CABLE SHOULD BE FREE OF SOLID MATERIAL GREATER THAN 100MM (2 IN) IN MAXIMUM DIMENSION OR WITH SHARP EDGES LIKELY TO DAMAGE IT. THE BALANCE OF BACKFILLSHOULD BE FREE OF SOLID MATERIAL GREATER THAN 200 MM (8 IN) IN DIAMETER. BACKFILL MATERIAL SHOULDBE ADEQUATELY COMPACTED.

7. REFER TO ARRAY GROUNDING DETAIL FOR BARE COPPER GROUND TRENCH ROUTING.

8. FEEDER ROUTING SHOWN DIAGRAMMATICALLY, COORDINATION WITH SITE CONDITIONS REQUIRED.

2'-0"MINIMUM

1'-0"MINIMUM

1-0"MINIMUM

BACKFILL, REFER TO GENERALNOTE 5

MAGNETIC WARNING TAPE,REFER TO GENERAL NOTE 3 & 4

2'-0"MINIMUM

1'-0"MINIMUM

1-0"MINIMUM

BARE COPPER GROUND SIZEDAS SPECIFIED, REFER TO ARRAYGROUNDING PLAN

3" MINIMUM TRENCH EDGETO BARE COPPER GROUND

3" MINIMUM TRENCH EDGETO BARE COPPER GROUND

3" MINIMUMTRENCH EDGE TO

CONDUIT

4" MINIMUMBETWEEN CONDUITS

3" MINIMUMTRENCH EDGE TO

CONDUIT4" MINIMUM

BETWEEN CONDUITS

SCALE: NONETYPICAL SINGLE CONDUIT TRENCH2

SCALE: NONETYPICAL MULTIPLE CONDUIT TRENCH3

A16

10

A8

A16

A16

A16

A8

A8

A8

A16

A16

A16

A16

A16

A16

B

B

A16

A8

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SITE

PLA

N -

AC A

ND

COM

MU

NIC

ATIO

N F

EEDE

R RO

UTI

NG

PV2.5

SCALE: 1/32"=1'-0"SITE PLAN - AC AND COMMUNICATION FEEDER ROUTING1

GENERAL NOTES:

1. REFER TO EQUIPMENT SCHEDULE AND SINGLE LINE DIAGRAM FOR SPECIFICATIONS.

2. ALL UNDERGROUND RACEWAY SHALL BE SCHEDULE 40 PVC. TRANSITIONS BELOW TO ABOVE GRADE SHALL BEPER CONDUIT STUB UP DETAIL.

3. FOR TRENCHES 24" WIDE AND LESS, ONLY ONE RUN OF MAGNETIC ELECTRICAL WARNING TAPE SHALL BEREQUIRED PER DETAIL 3.

4. FOR TRENCHES WIDER THAN 24" ONE PIECE OF TAPE SHALL BE LOCATED AT EACH SIDE OF THE TRENCH WITHADDITIONAL RUNS PROVIDED AS NECESSARY. THE MAXIMUM DISTANCE BETWEEN TAPE RUNS SHALL BE 24" ONCENTER.

5. TRENCH BOTTOMS: EXCAVATE TRENCHES 3" DEEPER THAN BOTTOM OF PIPE ELEVATION TO ALLOW FORBEDDING COURSE. HAND EXCAVATE FOR BELL OF PIPE. EXCAVATE TRENCHES 3" DEEPER THAN ELEVATIONREQUIRED IN ROCK OR OTHER UNYIELDING BEARING MATERIAL TO ALLOW BEDDING COURSE.

6. ALL BACKFILL SHOULD BE FREE OF MATERIALS THAT MAY DAMAGE THE CONDUIT OR CABLE SYSTEM. BACKFILLWITHIN 150 MM (6 IN) OF THE CONDUIT OR CABLE SHOULD BE FREE OF SOLID MATERIAL GREATER THAN 100MM (2 IN) IN MAXIMUM DIMENSION OR WITH SHARP EDGES LIKELY TO DAMAGE IT. THE BALANCE OF BACKFILLSHOULD BE FREE OF SOLID MATERIAL GREATER THAN 200 MM (8 IN) IN DIAMETER. BACKFILL MATERIAL SHOULDBE ADEQUATELY COMPACTED.

7. REFER TO ARRAY GROUNDING DETAIL FOR BARE COPPER GROUND TRENCH ROUTING.

8. FEEDER ROUTING SHOWN DIAGRAMMATICALLY, COORDINATION WITH SITE CONDITIONS REQUIRED.

2'-0"MINIMUM

1'-0"MINIMUM

1-0"MINIMUM

BACKFILL, REFER TO GENERALNOTE 5

MAGNETIC WARNING TAPE,REFER TO GENERAL NOTE 3 & 4

2'-0"MINIMUM

1'-0"MINIMUM

1-0"MINIMUM

BARE COPPER GROUND SIZEDAS SPECIFIED, REFER TO ARRAYGROUNDING PLAN

3" MINIMUM TRENCH EDGETO BARE COPPER GROUND

3" MINIMUM TRENCH EDGETO BARE COPPER GROUND

3" MINIMUMTRENCH EDGE TO

CONDUIT

4" MINIMUMBETWEEN CONDUITS

3" MINIMUMTRENCH EDGE TO

CONDUIT4" MINIMUM

BETWEEN CONDUITS

SCALE: NONETYPICAL SINGLE CONDUIT TRENCH2

SCALE: NONETYPICAL MULTIPLE CONDUIT TRENCH3

1PV4.1

11

D1

KEYED NOTES:

1. DIRECT BUS CONNECTION BETWEEN INVERTER AND MEDIUM VOLTAGE TRANSFORMER.

XX

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SCALE: 1/32"=1'-0"SITE PLAN - ARRAY GROUNDING1

SITE

PLA

N -

ARRA

Y GR

OU

NDI

NG

PV2.6

1PV4.2

GENERAL NOTES:

1. THE RACKING SYSTEM SHALL BE UL LISTED FOR GROUNDING CONTINUITY. COMPONENTS WITHIN THE RACKINGSYSTEM SHALL FORM AN ELECTRICALLY BONDED UNIT AND REQUIRE ADDITIONAL BONDING FROM ONEINDIVIDUAL RACK SECTION TO ADJACENT SECTIONS.

2. REFER TO SINGLE LINE DIAGRAM AND SCHEDULES FOR SPECIFICATIONS.

3. ARRAY EQUIPMENT GROUND CONDUCTOR SHALL BE RUN IN TRENCH WITH COMBINER DC CONDUITS WHEREPOSSIBLE.

4. GROUND FEEDER ROUTING SHOWN DIAGRAMMATICALLY, COORDINATION WITH SITE CONDITIONS REQUIRED.

5. PROVIDE AT LEAST 6'-1/2" OF WORKING CLEARANCE FOR INVERTERS AS PER NEC 110.26(A)(3) OR TO THE HEIGHTOF THE EQUIPMENT, WHICHEVER IS GREATER.

KEYED NOTES:

1. PROVIDE GROUND BRAID BETWEEN RACKING SECTIONS PER RACKING MANUFACTURER INSTRUCTIONS.

2. PROVIDE #10 COPPER (FEEDER A) EQUIPMENT GROUND CONDUCTOR (EGC) FROM THE COMBINER BOX GROUNDBAR TO RACK ON ADJOINING ROW. EGC SHALL BE RUN WITH ASSOCIATED COMBINER BOX STRING FEEDERS.

3. PROVIDE #10 COPPER (FEEDER A) EQUIPMENT GROUND CONDUCTOR (EGC) FROM THE COMBINER BOX GROUNDBAR TO RACK ON ADJOINING ROW ASSOCIATED WITH THE COMBINER BOX. EGC SHALL BE RUN WITHASSOCIATED COMBINER BOX STRING FEEDERS.

4. PROVIDE #1 ALUMINIUM (FEEDER B) EQUIPMENT GROUND CONDUCTOR (EGC) FROM COMBINER BOX GROUNDBAR TO ASSOCIATED INVERTER GROUND BAR. EGC SHALL BE RUN IN CONDUIT WITH ASSOCIATED PV DC INPUTCONDUCTORS.

5. PROVIDE #6 BARE COPPER (FEEDER K) JUMPER FROM THE COMBINER BOX GROUND BAR TO THE COMBINER BOXMOUNTING STRUCTURE.

6. PROVIDE #3/0 BARE COPPER (FEEDER L) ARRAY SUPPLEMENTAL GROUNDING ELECTRODE THE LENGTH OFARRAY.

7. PROVIDE #6 BARE COPPER (FEEDER K) BONDING JUMPER VIA IRREVERSIBLE CRIMP FROM ARRAY SUPPLEMENTALGROUNDING CONDUCTOR IN TRENCH TO POST OF RACKING. IRREVERSIBLE CRIMP SHALL BE UL LISTED FORGROUNDING AND BONDING. ENSURE ALL CONNECTIONS ARE TORQUED TO MANUFACTURER'S SPECIFICATIONS.

8. PROVIDE #6 BARE COPPER (FEEDER K) BONDING JUMPER VIA IRREVERSIBLE CRIMP FROM ARRAY SUPPLEMENTALGROUNDING CONDUCTOR IN TRENCH TO THE COMBINER BOX MOUNTING STRUCTURE. IRREVERSIBLE CRIMPSHALL BE UL LISTED FOR GROUNDING AND BONDING.

9. BOND ARRAY GROUNDING ELECTRODE VIA IRREVERSIBLE CRIMP.

#

1PV5.0

12

9

SCALE: NONEREAR ELEVATION - COMBINER & RACK GROUNDING2

COM

BIN

ER B

OX

2PV2.6

1 2 A 5

7

8

K

K

6 L

4 B

3 A

3 A 2 A

7 K

6 L

7 K4 B

5

8 K

L

L

L

9

9 9

SCALE: NONESIDE ELEVATION - COMBINER & RACK GROUNDING3

3PV2.6

A1-1

A1-2

A1-3

A1-4

A1-5

A1-6

A1-7

A1-8

A1-9

A1-1

0

A1-1

1A1

-12

A1-1

3A1

-14

A1-1

5A1

-16

A2-1

A2-2

A2-3

A2-4

A2-5

A2-6

A2-7

A2-8

A2-9

A2-1

0

A2-1

1A2

-12

A2-1

3A2

-14

A2-1

5A2

-16

A2-1

7A2

-18

A2-1

9A2

-20

A2-2

1A2

-22

A2-2

3A2

-24

A3-1

A3-2

A3-3

A3-4

A3-5

A3-6

A3-7

A3-8

A3-9

A3-1

0

A3-1

1A3

-12

A3-1

3A3

-14

A3-1

5A3

-16

A3-1

7A3

-18

A3-1

9A3

-20

A3-2

1A3

-22

A3-2

3A3

-24

A3-2

5A3

-26

A3-2

7A3

-28

A1-1

7A1

-18

A1-1

9A1

-20

A1-2

1A1

-22

A1-2

3A1

-24

A1-2

5A1

-26

A1-2

7A1

-28

A2-2

5A2

-26

A2-2

7A2

-28

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAYSCALE: 1/16"=1'-0"PARTIAL PLAN - STRING LAYOUT NORTH1

PART

IAL

PLAN

- ST

RIN

G LA

YOU

T N

ORT

H

PV3.0

13

GENERAL NOTES:

1. EACH STRING SHALL BE LABELED AS DESIGNATED WITH SHRINK TUBE.

2. LABELS SHALL BE LOCATED AT CONNECTOR ON BOTH POSITIVE AND NEGATIVE SIDES, AND AT THE CONNECTOR BOX.

A#-#

#A#

-##

SOURCE CIRCUIT NUMBERCOMBINER DESIGNATION

NEGATIVE END OFPV SOURCE CIRCUIT

POSITIVE END OFPV SOURCE CIRCUIT

SCALE: NONETYPICAL TWO STRING DETAIL2

A4-1

A4-2

A4-3

A4-4

A4-5

A4-6

A4-7

A4-8

A4-9

A4-1

0

A4-1

1A4

-12

A4-1

3A4

-14

A4-1

5A4

-16

A4-1

7A4

-18

A4-1

9A4

-20

A4-2

1A4

-22

A4-2

3A4

-24

A5-1

A5-2

A5-3

A5-4

A5-5

A5-6

A5-7

A5-8

A5-9

A5-1

0

A5-1

1A5

-12

A5-1

3A5

-14

A5-1

5A5

-16

A5-1

7A5

-18

A5-1

9A5

-20

A5-2

1A5

-22

A5-2

3A5

-24

A6-1

A6-2

A6-3

A6-4

A6-5

A6-6

A6-7

A6-8

A6-9

A6-1

0

A6-1

1A6

-12

A6-1

3A6

-14

A6-1

5A6

-16

A6-1

7A6

-18

A6-1

9A6

-20

A6-2

1A6

-22

A6-2

3A6

-24

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

N

KEY PLAN - OVERALL ARRAY

SCALE: 1/16"=1'-0"PARTIAL PLAN - STRING LAYOUT SOUTH1

PART

IAL

PLAN

- ST

RIN

G LA

YOU

T SO

UTH

PV3.1

GENERAL NOTES:

1. EACH STRING SHALL BE LABELED AS DESIGNATED WITH SHRINK TUBE.

2. LABELS SHALL BE LOCATED AT CONNECTOR ON BOTH POSITIVE AND NEGATIVE SIDES, AND AT THE CONNECTOR BOX.

14

SCALE: NONETYPICAL TWO STRING DETAIL2

A#-#

#A#

-##

SOURCE CIRCUIT NUMBERCOMBINER DESIGNATION

NEGATIVE END OFPV SOURCE CIRCUIT

POSITIVE END OFPV SOURCE CIRCUIT

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

PART

IAL

PLAN

-EQ

UIP

MEN

T PA

D DI

MEN

SIO

NS

PV4.0

SCALE: 1/2"=1'-0"PARTIAL PLAN - EQUIPMENT PAD DIMENSIONS1

LINE TYPE LEGEND:

CONCRETE PAD

EQUIPMENT

PROVIDED BY MANUFACTURER/ OTHERS

15

25'-6"

13'-6"

3'-11 1/4"

2'-10 1/2"

12'-6"

2'-4 1/2"

2'-6 3/4"

14'-4"

10 1/2"

6"

1'-4"

6"

1'-8"

6"

1'-6"

6"6"

2'-0"

4

5

6

78

9

1214

1113

9'-11 3/8"

3'-0"

5'-11 3/4"

8'-8"

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

PART

IAL

PLAN

-EQ

UIP

MEN

T PA

D AC

AN

D

PV4.1

SCALE: 1/2"=1'-0"PARTIAL PLAN - EQUIPMENT PAD AC AND COMMUNICATION FEEDER ROUTING1

LINE TYPE LEGEND:

CONCRETE PAD

EQUIPMENT

PROVIDED BY MANUFACTURER/ OTHERS

AC FEEDERS

COMMUNICATIONS

MEDIUM VOLTAGE FEEDERS

TO MV FUSED SWITCH

16

4

5

789

12

13

1411

6E

D

EFG

H

II J

COM

MU

NIC

ATIO

N F

EEDE

R RO

UTI

NG

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

PART

IAL

PLAN

-EQ

UIP

MEN

T PA

D GR

OU

NDI

NG

PV4.2SCALE: 1/2"=1'-0"PARTIAL PLAN - EQUIPMENT PAD GROUNDING1

LINE TYPE LEGEND:

CONCRETE PAD

EQUIPMENT

PROVIDED BY MANUFACTURER/ OTHERS

GROUND FEEDERS

4

6

5

17

GENERAL NOTES:

1. REFER TO EQUIPMENT SCHEDULE ON PV4.0 FOR SPECIFICATIONS.

78

9

121411

13

17

17

1717

TO MV FUSED SWITCH

TO ARRAY

KEYED NOTES:

1. PROVIDE IRREVERSIBLE BOND TO GROUND RING.

1 1 1

1

11

1

1

XX

LL

L

L

L

L

L

L

K

L

L

L

1

L

REV

DATE

DESC

RIPT

ION

NRE

CASU

NDA

REF

EREN

CE D

ESIG

N1,

050K

WAC

, 1,5

00VD

C

TITL

E:

PRO

JECT

:

1609

HER

ITAG

E CO

MM

ERCE

CT

WAK

E FO

REST

, NC

2758

7PO

WER

SECU

RESO

LAR.

COM

THIS

LIN

E SH

OU

LDM

EASU

RE O

NE

INCH

DATE:

SHEET:04.06.2017

CON

FIDE

NTI

AL&

PRO

PRIE

TARY

PREL

IMIN

ARY

NO

T FO

RCO

NST

RUCT

ION

OF 18

FEN

CE G

ROU

NDI

NG

DETA

IL

PV5.0

18

SCALE: NTSFENCE GROUNDING DETAIL1

GENERAL NOTES:

1. ALL FENCE GROUNDING POINTS SHALL BE LOCATED WITHIN FENCE PERIMETER.

2. GROUND CORNER POSTS AND ADDITIONAL POSTS AT 500' INTERVAL.

3. GROUND ALL GATE POSTS.

KEYED NOTES:

1. PROVIDE EXOTHERMIC WELD TO TOP RAIL.

2. #6 BARE COPPER WIRE, TYPICAL UNLESS NOTED OTHERWISE.

3. PROVIDE SPLIT BOLT TO CONNECT WIRE TO FENCE FABRIC.

4. PROVIDE EXOTHERMIC WELD TO FENCE POST.

5. 3/4" X 10' COPPER CLAD GROUND ROD BONDED TO BARE COPPER.

6. FLEXIBLE GROUND BRAID SECURED TO GATE.

7. GATES SHALL BE BONDED TOGETHER.

8. TO ARRAY SUPPLEMENTAL GROUNDING ELECTRODE.

FINISHED GRADE

1

2

3

4

5 5 5

4 46 6

3

1

3

1

7

8


Recommended