2
PRAHER - QUALITY - SERVICE - INNOVATION Technical data General: Power supply: 230 VAC 50/60 Hz 115 VAC 50/60 Hz 24 VAC 50/60 Hz Digital time controlled backwash: 7 days 24 hour Grässlin digital clock (battery back up for timer 2 month) Pressure switch: MSPS-FF-100SS: 0,69 - 6,9 bar MSPS-FF-15SS: 0,10 - 1,0 bar Filter- and backwash clock: 7 days 24 hour Grässlin digital clock (battery back up for timer 2 month) Enclosure: IP 54 Valve type: 11/2” SM-TM, 2” SM-TM, 3” SM SM = Side Mount TM = Top Mount gradually adjustable! Backwash time: Rinse time: 20 sec. - 11 min. 20 sec. - 4 min. 20 sec. Cut in delay: 25 sec. - 23 min. Pump cut in delay: 20 sec. Flow rate: 3 1 1/2” 18 m /h (80 Gpm) 3 2” 35 m /h (155 Gpm) 3 3” 75 m /h (330 Gpm) Operating pressure: Valve ABS: max. 3,5 bar (20°C); GFK: 5 bar (20°C) flange connections: - Thread - Bolt - down flange - Clamp flange Technical specification: for exampel.: TYPE PRAHER Superstar E-6000 / F2 ABS 1 1/2” Side Mont valve Features: - water and chemical resistant pad switch - CE - approved (European electrical code) - Backwash, rinse time and cut in delay are gradually adjustable - pleasing design - ISO 9001 - fast and trouble free installation - economic backwash valve solution for your filtersystem - E 6000 / F2 11/2” and 2” with manual override - free of corossion only E - 3000 / F2 only E - 2000 / F2 UND E - 6000 / F2 only E - 6000 / F2 VERSION Top Mount - suitable for all well known filter brands Subjects to technical modification! M I K L B H C A D E F G P Q N 1 1/2" 2" 3" mm mm mm A 99,0 110,0 170,0 B 182,0 228,0 330,0 C 32,0 38,0 50,0 D 47,0 60,0 85,5 E 60,0 81,0 110,0 F 164,0 210,0 306,0 G 270,0 312,0 436,0 H 38,0 34,0 50,0 I 87,5 115,0 165,0 K 175,0 230,0 330,0 L 250,0 250,0 250,0 M 160,0 160,0 160,0 N 280,0 322,0 P max. 378,0 420,0 Q max. 135,0 135,0 G F E D A C H B L K I M 1 1/2”, 2” E-6000 / F2 long working life durable chemical resistant 100 % water resistant E-2000 / F2 E-3000 / F2 : 1 1/2”, 2”, 3” E-6000 / F2: 3” E - 2000 / F2; E - 3000 / F2 E - 6000 / F2 Symbolfoto E-2000 / F2 - 3” Symbolfoto E-3000 / F2 - 1 1/2” Symbolfoto E-6000 / F2 - 1 1/2” Pressure Time int. Filter pump control unit E - 2000 / F2 E - 3000 / F2 E - 6000 / F2 Control system TYPE SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2 1 1/2”, 2”, 3” - 230V; 115V und 24V* Side Mount connection: BSP - thread ports
Transcript
Page 1: SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2 1 … E-2000-3000-6000 F englisch.pdf · PRAHER - QUALITY - SERVICE - INNOVATION Technical data General: Power supply: 230 VAC 50/60

PRAHER - QUALITY - SERVICE - INNOVATION

Technical data

General:

Power supply: 230 VAC 50/60 Hz 115 VAC 50/60 Hz 24 VAC 50/60 Hz

Digital time controlled backwash: 7 days 24 hourGrässlin digital clock (battery back up for timer 2 month)

Pressure switch:MSPS-FF-100SS: 0,69 - 6,9 barMSPS-FF-15SS: 0,10 - 1,0 bar

Filter- and backwash clock: 7 days 24 hourGrässlin digital clock (battery back up for timer 2 month)

Enclosure: IP 54

Valve type: 11/2” SM-TM, 2” SM-TM, 3” SM SM = S ide Mount TM = Top Mount

gradually adjustable!Backwash time: Rinse time:20 sec. - 11 min. 20 sec. - 4 min. 20 sec.Cut in delay: 25 sec. - 23 min.

Pump cut in delay: 20 sec.

Flow rate:31 1/2” 18 m /h (80 Gpm)3 2” 35 m /h (155 Gpm)3 3” 75 m /h (330 Gpm)

Operating pressure:

Valve ABS: max. 3,5 bar (20°C); GFK: 5 bar (20°C)

flange connections:

- Thread - Bolt - down flange- Clamp flange

Technical specification:

for exampel.:TYPE PRAHER Superstar E-6000 / F2 ABS 1 1/2” Side Mont valve

Features:

- water and chemical resistant pad switch- CE - approved (European electrical code)- Backwash, rinse time and cut in delay are gradually adjustable- pleasing design- ISO 9001- fast and trouble free installation- economic backwash valve solution for your filtersystem- E 6000 / F2 11/2” and 2” with manual override- free of corossion

only E - 3000 / F2

only E - 2000 / F2 UND E - 6000 / F2

only E - 6000 / F2 VERSION

Top Mount

- suitable for all well known filter brandsSubjects to technical modification!

M

I

K

L

B

H C

A

DEF

G

P

Q

N

1 1/2" 2" 3"

mm mm mm

A 99,0 110,0 170,0

B 182,0 228,0 330,0

C 32,0 38,0 50,0

D 47,0 60,0 85,5

E 60,0 81,0 110,0

F 164,0 210,0 306,0

G 270,0 312,0 436,0

H 38,0 34,0 50,0

I 87,5 115,0 165,0

K 175,0 230,0 330,0

L 250,0 250,0 250,0

M 160,0 160,0 160,0

N 280,0 322,0

P max. 378,0 420,0

Q max. 135,0 135,0

G

F

ED

A

CH

B

L

K

I

M

1 1/2”, 2”E-6000 / F2

long working life

durable

chemical resistant

100 % water resistant

E-2000 / F2E-3000 / F2 : 1 1/2”, 2”, 3”

E-6000 / F2: 3”

E - 2000 / F2;E - 3000 / F2

E - 6000 / F2

SymbolfotoE-2000 / F2 - 3”

SymbolfotoE-3000 / F2 - 1 1/2”

SymbolfotoE-6000 / F2 - 1 1/2”

Pressure Time int. Filter pump control unit

E - 2000 / F2

E - 3000 / F2

E - 6000 / F2

Control systemTYPE

SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2

1 1/2”, 2”, 3” - 230V; 115V und 24V*

Side Mount connection:

BSP - thread ports

Page 2: SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2 1 … E-2000-3000-6000 F englisch.pdf · PRAHER - QUALITY - SERVICE - INNOVATION Technical data General: Power supply: 230 VAC 50/60

03 / 01 © by Ludwig PRAHER, AUSTRIA

PRAHER - QUALITY - SERVICE - INNOVATION

3" Side-Mount SM 30

3V

[m /

h]

p[bar]

2" Top-Mount TM 22

2" Side-Mount SM 20

1 ½" Side-Mount SM 10

1 ½" Top-Mount TM 12

Flow - pressure diagramm (backwash position)

1,0

80

60

40

20

0,80,60,40,2

3" Side-Mount SM 30

3

Flow - pressure loss diagramm (Filter position)

1 ½" Top-Mount TM 12

1 ½" Side-Mount SM 10

2" Side-Mount SM 20

2" Top-Mount TM 22

p[bar]

V[m

/ h]

1,0

80

60

40

20

0,80,60,40,2

I : Filtration of medium (i.e. water)Pool - pump - valve (to filter) - filter - Valve (from filter) - pool

II : Drainage of pool with pump:Pool - pump - valve - drain

III : Cleaning up filter medium (i.e. sand) in upstream (reversed flow in filter):Pool - pump - valve (from filter) - filter - valve (to filter) - drain

V : Cleaning of filter medium (i.e. sand) after backwash Pool - pump - valve (to Filter) - filter - valve (from filter) - drain

pump

pool

drain

filter bottom

filter topII Waste

pump

pool

drain

filter bottom

filter top

I FILTER

pump

pool

drain

filter bottom

filter topIII Backwash

pump

pool

drain

filter bottom

filter top

V RINSE

pump

pool

drain

filter bottom

filter top

Technical data

CONTACTS

Contacts for valve sequencing of multiple valves:

4 amperes max.

Contacts for fireman switch (heater willshut off prior to backwashing)

4 amperes max.

Contacts for pump in all actuator positions(Filter, Backwash, Rinse, Drain):

8 amperes max.

Contacts for position backwash and rinse(for secondary backwash pump or bloweror two speed pump):

4 amperes max.

Contacts for auxilliary valve or backwash monitoring:

8 amperes max.

Contacts for position backwash only:

4 amperes max.

SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2

1 1/2”, 2”, 3” - 230V; 115V und 24V*

Field of application: Water treatment plant

18 19 20

13

27 2928

DELAY

VERZÖGERUNG

24 25 26

RINSEKLARSPšLEN RÜCKSPÜLEN

21 22 23

Serie

SEQUENCING

L1 N

BACKWASH

146 G 2

RR

LP004.0370.01.APraherPraher

sch

alte

r

sw

itch

pre

ssu

re

Dru

ck-

CK

SP

ÜL

EN

BA

CK

WA

SH

N.O/6

N.C/2

COM/G

N.O/14

N.C/29

N.O/27

Backwash

Rinse

Pump

Dealy

N.C/26

N.O/24

COM/13

COM/25

COM/19

N.C/20

N.O/18

COM/22

Ball valve

N.C/23

N.O/21

sch

alte

r

24V~ba

ll v

alv

e

1N

~ 5

0/6

0H

z

Ku

ge

lha

hn

115V~

Pu

mp

Pu

mp

e

Serie

230V~

Po

we

r S

up

ply

sp

an

nu

ng

Backwash

COM/28

Ve

rso

rgu

ng

s-

109

sw

itch

Le

ve

l-

Niv

ea

u-


Recommended