Page 1 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
SUPPLY OF TURN TABLE LADDER FOR & FIRE FIGHTING & RESCUE
Sr.
No
Name of firm Tender clause
ref.
Tender Terms/
Specifications
Queries Remarks
1 NK Fire and
Safety
GIDC phase 1
,opp. Anand
Tiles,
Wadhwan Dist.
Surendranagar
Gujarat
Section – V,
Schedule of
Requirement
6 months from the date of
contract
1)This is as very special equipment made to order. Even
the delivery of the Custom made chassis for this unit is
5-6 months. We request you to amend the delivery date
to 11 months from the date of advance payment.
It is clarified that the delivery period of TTL is increased to
10 months from the date of advance payment from 6
months as already mentioned in the tender document.
1.2- Section-
VI General
Requirement
The Turntable Ladder shall bedesigned as per the designed, operational stability and structural strength based on the criteria laid in EN 14043 or, Japanese safety standard or any other International standard and other norms and standards applicable for elevated raised
2)The terms “ Japanese Safety Standard or any other
International Standard” may be deleted because only
EN14043 is a Complete standaed specially meant for
Automatic Turntable Ladders and accepted all over the
world including Japan.
By changing the words, it is possible that one bidder
may offer TTL as per Chinese standards, other bidder
may Malaysian standard, some other bidder may offer
Korean Standard and so on. Therefore it is essential that
the text be changed as under:
“ As per EN 14043 or other EQUIVALENT
INTERNATIONAL STANDARD applicable for
It is clarified that the TTL shall be confirming to EN 14043
and no equivalent standard is acceptable.
Page 2 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
platforms used for Fire Fighting and rescue operations.
automatic turn table ladder ACCEPTED
WORDLWIDE”
5.15.4 &
5.15.7
Technical
Specifications
Ladder Set
Button for engine Start/ Stop or emergency stop. Button for One man/Two man/ Three man selection/Fire man selection.
3)This requirement allows the operator to start and stop
the vehicle engine so that in case of prolonged
operations, fuel is not wasted But the Turntable Ladder
operations are still possible. The specification allows for
an EMERGENCY STOP button as an alternate to
Engine Start Stop button. These two have totally
different functions. The Emergency Stop button will
stop all the turntable ladder operations which is not what
is required. Therefore an amendment may please be
issued to delete the Emergency Stop Button.
In any case, an Emergency Stop Button is always
provided as mandatory.
Similarly One / Two / Three Man selection is mandatory
allowing the user to vary the cage load capacity. If this
is modified, a very critical feature of the TTL is being
compromised. It is therefore requested to delete the
words “Fireman Selection”
It is clarified that the word fire man selection has been
deleted from tender and it may be read as button for one
man/ two man /three man selection and the emergency
stop button is deleted from the tender.
10.1 &10.4
Technical
Specifications
Cage & Lift
The working cage shall be fix. In case of detachable cage, the working cage shall be
4)It is very important that a detachable cage be provided
on a TTL. This will allow the ladder set to be directly
placed near a window / balcony for the victims near a
window/ balcony for the victims to climb down or get
It is clarified that the condition in the tender document remains unchanged.
Page 3 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
attached to the tip of top section and it shall be foldable. In case of detachable case. The cage shall be quick removable type whenever needed.
inside the lift in case if the number of victims are much
higher. With a fixed cage, all the victims would have to
first enter the cage through a platform and then climb on
to the ladder sets making it much time consuming
10.8.4&10.8.6
- Technical
Specifications
Cage & Lift
Button for engine Start/ Stop or emergency stop. Button for One man/Two man/ Three man selection/Fire man selection.
5)This requirement allows the operator to start and stop
the vehicle engine so that in case of prolonged
operations, fuel is not wasted but the Turntable Ladder
operations are still possible. The specification allows for
an EMERGENCY STOP button as an alternate to
Engine Start Stop button. These two have totally
different functions. The Emergency Stop button will
stop all the turntable ladder operations which is not what
is required. Therefore an amendment may please be
issued to delete the Emergency Stop Button.
In any case, an Emergency Stop Button is always
provided as mandatory.
Similarly One / Two / Three Man selection is mandatory
allowing the user to vary the cage load capacity. If this
is modified, a very critical feature of the TTL is being
compromised. It is therefore requested to delete the
words “Fireman Selection”
It is clarified that the word fire man selection has been
deleted from tender and it may be read as button for one
man/ two man /three man selection and the emergency stop
button is deleted from the tender.
10.13- Access to the lift shall 6)Please delete the words “or through the fixed stop to It is clarified that the lift shall touch the ground level or
Page 4 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
Technical
Specifications
Cage & Lift
be possible at the rear of the vehicle from the ground due to extended rails to lower the lift near to ground level or through the fixed stop to the platform.
the platform”. With these words, the lift can only reach
upto the platform – which means the lift can be operated
only when the cage if front facing. This totally defeats
the purpose of having lift if it is not operable in all
angles.
Lift forms the very heart of any turntable ladder. The
very purpose of the lift is to bring people from a height
of 55 meter to the ground safely. This is very useful
since at the time of fire or emergency, most of the
casualties are either non-mobile or injured or in a state
of shock that they cannot climb down the ladder safely.
With a lift installed, it will ensure maximum safety of
casualties even when they are injured or non-mobile.
Therefore it is essential that the lift must reach the
ground level so that the casualties can ground level so
that the casualties can dismount safety to the ground.
Please refer to the attached picture.
If the lift is not able to reach the ground, does having a
lift serve any purpose ?
If the lift can reach to the ground, it can be used in all
the directions ( irrespective of any rotation of the
ladder). However, if the lift does not reach the ground, it
can be used only when the cage if facing the front
direction. Therefore by allowing this, the operational
capabilities of the turntable ladder is reduced greatly.
almost near to the ground level.
Page 5 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
Therefore it is our earnest request that the words may be
deleted.
12.2 –
Technical
Specifications
Backup for the
Hydraulic
System
The power generator shall be able to start from main control panel or manually.
8)Please delete the words “or manually” it is very
important that the backup power source must start from
the control panel. It is not possible that if the main
system fails, the fireman climbs down the ladder and
then start the power generator manually. By allowing
this feature, the functional aspect as well as the safety of
victims and fireman are greatly compromised.
It is clarified that the word manually has been deleted from
the tender.
17.1-
Technical
Specifications
the water
The horizontal movement up to 300 left side and right side. 150 on both sides and total 300
9)Kindly delete the words “15o on both sides and total
30 0”,. A movement of 15 degrees is too small for
providing any kind of protection with monitor.
By allowing the words “15 o on both sides and total 30
o” an inferior quality of apparatus is being allowed to
participate.
It is clarify that the the condition is modified to the extent
that horizontal movement may be read as 30 degree instead
of 15 degree.
Priced Bid
Format
10)The online and offline priced bid format are differing. Kindly update the online priced bid as per the tender document priced bid format given on page 49 of the bid document.
It is clarified that the price bid format has been amended
accordling.
Due Date of
the tender
26th February 2015 11)It may please be extended by atleast 10-15 days since
the tender is quite big and requires a huge amount of
paperwork for preparing the tender.
It is clarified that the last date of submission of technical bid as well as financial bid is extended upto 19th of March.
2 NAFFCO
FZCO
Dubai, United
We Are A Qualified Manufacturer Of Aerial Ladder Platforms Upto 70m & Hydraulic Turntable Ladder- Up To 55m As Per EN Standard In Dubai.
It is clarified that the manufacturer must have
manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied
Page 6 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
Arab Emirates We Are Very Much Interested To Participate In Your Bid & For The Same We Request You To Also Allow Us An Extension Period Of Minimum 4 Week To Submit The Bid. Moreover This Being A Global tender we request you to eliminate the clause of supply reference in India with a performance certificate from Indian Firm brigade. We as a proven global manufacturer of Aerial truck can give you reference with performance world wide.
to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
3 Anlon IPS C-8,KSSIDC, Industrial Estate, Yelahanka, Banglore- 560064
13.2 The documentary evidence of the goods and services eligibility shall consist of a statement in the Price Schedule
Kindly let us know / suggest what document we should submit for this requirement
It is clarified that the company has to submit documentary
evidence of goods and services in the technical bid only.
13.3-a A detailed description of the essential technical and performance characteristics of the goods;
Can we submit Technical Specifications. It is clarified that condition in the tender remained
unchanged and performance certificate must be submitted.
14.3 Bid Security : Shall be either in the form of demand draft or a bank guarantee from a first class
In page no.2 & 36 of the tender document it is written that EMD should be submitted online. Kindly clarify the mode of payment.
It is clarified that earnest money has to be submitted online only and No Bank Guarantee or demand draft will be accepted
Page 7 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
international bank
Financial Bid Should this be submitted as a hard copy
16.2 A Bid Form in the bid document must be filled by the bidder mentioning all supply to be intended along with schedule number. In case of non-filling of Bid form a bid will be treated as rejected .Bidders are required to quote their intended supply and their total prices in bid form only.
1) Since the bid form shall contain price information, please suggest if form has to be submitted along with Price Bid.
2) If this bid form has to be uploaded along with technical Bid, then price shall not be indicated.
3) If the bid form has to be uploaded along with financial bid, please let us know if the provision for the same has same provided online.
It is clarified that the price bid format has been up loaded
in the tender document.The bid form has to be uploaded.
26 Domestic preference – As per GOVERNMENT OF PUNJAB NORMS
Kindly clarify It is clarified that this clause has been deleted in the tender document.
7 Warranty Kindly clarify if this Warranty bond should be provided after the work order is received
It is clarified that the Warranty bond should be provided after the work order is received.
B Qualification Criteria: At least one performance certificate issued by any fire brigade in India for Turn Table Ladder of same make & model offered of 55 meters or higher
1. We request your good offices to kindly allow us to submit performance certificates which are issued for similar machines but not limited to 55 meters height.
2. We have supplied similar models globally ; please allow us to submit the performance certificates received from global customers.
It is clarified that the manufacturer must have
manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
Page 8 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
capacity (55 meter working height & 270 Kgs cage load capacity) mounted on the same chassis as quoted in this tender shall be submitted along with the tender. This unit shall be in service with the customer for at least 2 years from the date of opening of the bid. Documentary evidence for the same must be provided along with the bid.
3. Kindly allow us to submit performance certificates issued for TTLs which are higher and lower than the tender specified height, which are functioning well in lndia.
1.1 The chassis shall be either MAN / VOLVO/ MERCEDES BENZ / Equivalent make […..]
“ Equivalent Make” is very uncommon in tenders as compared to a lot of other technical criteria in this tender. It leaves ample for interpretation. We recommend to remove “ Equivalent make”
It is clarified that the chassis of MAN / VOLVO/ MERCEDES BENZ are acceptable and no equivalent make is acceptable.
1.3 […] the turntable Ladders shall have a Computer Controlled oscillation Damping system to ensure stable and smooth operation of the unit at heights..
A computer Controlled Oscillation Damping system is absolutely unnecessary if the manufacturer can create sufficient stability from within the ladder set. Kindly amend that point.
It is clarified that the apart from computer Controlled Oscillation Damping system or any other technology with proven track record in the TTL supplied in India.
2.1 The chassis shall be either See above It is clarified that the chassis of MAN / VOLVO/ MERCEDES
Page 9 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
MAN / VOLVO/ MERCEDES BENZ / Equivalent make […..]
BENZ are acceptable and no equivalent make is acceptable.
3 3.7:Loading capacity of lifting eye under the first ladder set : 2000 kg Minimum
Rosenbauer TTL loading capacity of lifting eye under the First ladder set : 4000 kg. The main purpose of having a crane is to lift a vehicle upto LCV ( Light Commercial Vehicle)
It is clarified that the condition in the tender document
remains unchanged.
8 Stabilising / jacking System : 8.2 – the Jacks shall be diagonal type configuration, each side shall have two separate stabilizes. This is to ensure that the jacks can be extended even when the vehicles are parked on narrow by lanes close to the unit. This will also ensure that it would be easier for the fire crew to walk over the Jacks even when fully extended.
There is only one EN certified TTL manufacturer for a type jacking system. In india 95% of the Aerial rescue and firefighting equipment are with H type jacking system due to the Indian street conditions. Therefore we request you good offices to accept also manufacturers/ offers for TTL with H type jacking system as it would offer a better operational stability apart from the advantage that tendering process will have sufficient participation.
It is clarified that the H type jacking system is also
acceptable apart from the jacking system already proposed
in the tender document.
10.12 Rescue lift capacity shall not be less than 180 kg
It is recommended to keep the permissible weight of the lift identical to the permissible weight in the cage. That way all the rescued people from the cage can go into the lift without being forced to wait. Additionally
It is clarified that the condition in the tender document
remains unchanged.
Page 10 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
rescuing capacity is 50% higher.
1 11 Hydraulic System: 11.2 when no operation of the ladder is activated, the pump shall rotate on minimum flow and minimum pressure. When the control lever or oil pressure foot paddle is pressed, the engine should automatically go to pre set rpm and also activate the necessary hydraulic oil supply to all the circuits.
Without any operation of the aerial device, the pump shall operate on minimum flow and minimum pressure. When one of the movements is operated the control valve automatically shall increase the pressure to a pre-set constant level and the oil flow to the amount that is needed for the movements activated. ( According to the tender clause no. 11.2 it creates high noise level and reduces the life of the engine)
It is clarified that the condition in the tender document
remains unchanged.
4 EMPIRE INDUSTRIAL EQUIPMENT 414, Senapati Bapat Marg, Lower Parel, Mumbai.
Page no. 1 as you are aware that these turn table ladders
are tailor made special machines, hence to make a
comprehensive proposal, we request you to extend the
proposal submission date by a period of 30 days from
the date of corrigendum issue date.
It is clarified that the last date of submission of technical bid as well as financial bid is extended upto 19th of March.
Page 32, as mentioned these are tailor made special
machines incorporating special features to suit your
need, hence we request you to keep the delivery date as
It is clarified that the delivery period of TTL is increased to
10 months from the date of advance payment from 6
months as already mentioned in the tender document.
Page 11 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
10 months, FOB from the date of opening of L/C.
Page 35 of 55, we request you to keep the height as
range specific and make it 54 to 55 meters, instead of 55
meters, which is a normal practice of giving a range
instead of fixing on a particular figure. This is done in
order to accommodate more bidders and also it will
satisfy your functional requirement.
It is clarified that the condition in the tender document
remains unchanged.
Page 33 of 55 clause 1.1 we request you to keep the
wheel base as range specific and make it 4800 to 5000
instead of 5000.
It is clarified that the wheel base may be read as 4800-
5000mm instead of 5000mm only.
Page 33 of 55, clause 1.3 this particular feature “
computer controlled oscillation damping system “ is a
particular feature of one specific manufacturer, in our
machine this is not required, hence this clause may be
deleted.
It is clarified that the apart from computer Controlled Oscillation Damping system or any other technology with proven track record in the TTL supplied in India.
Page 33 of 55, clause 1.5, we request to make this range
specific and mention height will be 52 to 53 meters to
the cage bottom from the ground and not specifically 53
meters.
It is clarified that the height may be read 52-53meters
instead o 53 meters.
Page 34 of 55 clause 2.1 we request you to make this
range specific and mention wheel base will be 4800 to
5000 instead of 5000mm
It is clarified that the wheel base may be read as 4800-
5000mm instead of 5000mm
Page 35 of 55, clause 2.18 this being an international
Competitive Bidding, it is expected that manufacturers
from throughout the world would participate, hence it is
not mandatory that these bidders necessarily should
have a supply reference in India instead they have
It is clarified that the manufacturer must have
manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of
Page 12 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
extensive supply reference worldwide, hence this
particular clause “bidder must have supplied quoted
model to fire brigade” should be deleted. This would not
only bring more competition but also attract most
competitive price.
supplies as well as documentary evidence in support of equipment supply and its performance certificates.
Page 35 of 55 clause 3.1 as mentioned earlier, working
height should be range specific and it should be
mentioned as 54 to 55 meters as mentioned above point
no 3
It is clarified that the condition in the tender document
remains unchanged.
"0' Page 35 of 55, clause 3'2, we request you to modify these clause and mention height to working cage bottom,52 to 55 meters instead'of 53 to 55 meters as mentioned above point no.6.
It is clarified that the condition in the tender document
remains unchanged.
' Page 35 of 55, clause 3'10, thiitclause is i'ndo,mRlete, it should be mentioned as ,,as per EN 14043 or other international stdndards,
It is clarified that the TTL shall be confirming to EN 14043
and no equivalent standard is acceptable.
Page 39 of 55, clause 8'2, we request you to modify this clause and mention ,,the jacks shall be diagonal type configuration or H Type ( H type to be included
It is clarified that the H type jacking system is also
acceptable apart from the jacking system already proposed
in the tender document.
' Page 40 of 55, clause 1o'1 and clause L0,2, we request you to make it range specific and mention weight should be 200 to 270 kgs which is more than enough to accommodate more than 3 persons.
It is clarified that the conditions remained unchanged.
' Page 44 of 55, clause !7.2,we request you to amend it and make it ,,height should be 52 to 53 meters cage bottom ,,
It is clarified that the conditions remained unchanged.
Page 13 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
' Page 47 of 55, clause A, we request you to amend the clause as the ,,bidder must have supplied at least 20 nos Turn Table Ladder of same make with height 54 to 55 meters and 200 to 270 kgs cage load,,
It is clarified that the manufacturer must have
manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
' Page 47 of 55 , clause A , as mentioned vide clause 2.18, this being a International competitive bidding , the clause for Indian suppty reference to be eliminated
It is clarified that the condition in the tender document
remains unchanged.
. Page 47 of 55 , we request you to eliminate this clause as this being an International Competitive bidding, this clause B has not got any relevance , hence this clause B, to be eliminated
It is clarified that the condition in the tender document
remains unchanged.
. Page 47 of 55, clause H, the authorized representative should be a manufacturer of Fire & Emergency Vehicles , to be deleted as it is not necessary on the part of the authorized representative to be a manufacturer of Fire & Emergency Vehicles as because the equipment will be LO}% imported.
It is clarified that the supplier shall not have experience of
manufacture of fire and emergency vehicles.
Page 48 of 55 , Sr. No. 1 , we request you to amend this clause as ladder height should be 54 to 55 meters
It is clarified that the condition in the tender document
remains unchanged.
. Page 49 of 55 , we request you to' amend the height of ladder should be mentioned 54 _ to 55 meters
It is clarified that the condition in the tender document
remains unchanged.
Page 35 of 55 ,we request you to amend this point 3.5 It is clarified that the condition in the tender document
Page 14 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
,as , safe working load will be 200 to 27O kgs remains unchanged.
We request you to please accept the Earnest Money Deposit/ bid bond in the form of Bank Guarantee, the format for which is already available in the tender document
It is clarified that the condition in the tender document
remains unchanged.
5
Joseph Leslie & Company Leslico House,3rd Floor,Prof.V.S.Agashe Road,Dadar(W),Mumbai 400028,India.
Delivery Period as stated in your tender document: 06 months from the date of opening of LC.
We request you to please change/amend the same to read as: 10-11 months from the date of opening of LC.
It is clarified that the delivery period of TTL is increased to
10 months from the date of advance payment from 6
months as already mentioned in the tender document.
Section no VI- A, point no H of the Qualification criteria:
The bidder should have their authorized agency/ representative / distributor/ which shall be
We failed to understand link between Turntable Ladder’s maintenance and manufacturing of fire and emergency tenders. We Joseph Leslie and Company LLP are the authorized service partners of MAGIRUS Gmbh, Germany and have been providing service and maintenance support PAN India successfully for the last few years. We have a
It is clarified that the supplier shall not have experience of
manufacture of fire and emergency vehicles.
Page 15 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
`
manufacturer of Fire and Emergency vehicles to look after the maintenance and service of TTL.
team of engineers and technicians to look after your Turntable Ladder with the spare part support. Therefore we request you to change the above said point to read as “The Bidder should have their authorized agency/ representative / distributor to look after the maintenance and service of the Turn Table Ladder.
Page 16 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
S.No Name of the Firm Tender clause
ref.
Tender Terms/ Specifications Queries Remarks
6. Rosenbauer Rosenbauer International AG, Paschinger strabe 90, 4060 Leonding, Austria.
We M/S Rosenbauer International AG have purchased the above tender documents and had a detailed study of the same. We have observed some anomalies I the Technical Specifications and Eligibility criteria mentioned in the bidding document which are as follows:
1. Section VI, Clause 8.2 of Technical
Specifications (Page 39) : It is mentioned
that “The Jacks shall be diagonal type
configuration” means A-Types or X-
Types of jacks. Only one company from
Germany, M/s Magirus manufactures
this particular diagonal types jacks
which means that no other company
expect M/s Magirus can compete in the
above mentioned bid and hence
arbitrarily making it an Unhealthy
Competition. Almost all the leading
manufacturer of TTL around the globe,
produces H-type of Jacks which
isdistinctly superior to A-type jacking
system. Please refer Annexure „A‟ to
compare its advantages. Even M/s
Magirushas their Hydraulic Platform
with H-type jacking system.
It is clarified that the H type
jacking system is also
acceptable apart from the
jacking system already
proposed in the tender
document.
Page 17 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
2. Section VI A of Qualification Criteria Point A (Page 47) : The clause says that “The Manufacturer must have supplied at least 25 TTL of same make and model offered of 55 meters or higher capacity during last 7 years and must have supplied to India minimum 3 nos. TTL of same make & model offered of 55 meters or higher capacity during last 7 years and must have supplied to India minimum 3 nos. TTL of same make & model offered of 55 meters or higher capacity” We have supplied 2849 Turntable Ladders of different sizes in 76 countries around the world, including about seventeen TTLs of 55 meters height or above. However , Rosebauer has started supplying its product in India only from 2011.We have already supplied 5 TTls to Indian customers with heights of 32,39,40,and 62 mtrs.Recent supplied machine is our L62 with 62m rescue height, the world highest turntable ladder, supplied to Jindal Group in India. Only one company has supplied 3nos. of 55 mtrs to India within the last 7 years. This will lead to a
It is clarified that the
manufacturer must have manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
Page 18 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
single bid evaluation. We therefore kindly request you to change your tender documents accordingly.
3. Section VI A of Qualification Criteria Point H (Page 47): The clause says that “the bidder should have their authorized agency/ representative/ distributor which shall be manufacturing of Fire & Emergency Vehicles to look after the maintenance and service of the TTL”. We want to submit that Rosenbauer is supplying its TTL and other products in more than 100 countries around the globe and maintain the quality and safety on international standards. For maintenance and services, Rosenbauer fully trains and educates their authorized partners/agencies in all countries. Our Indian partner M/s. AnlonIPS have 5 Rosenbauer trained Service Engineers and 32 Technical support engineers in India. M/s Anlon IPS Engineering Pvt. Ltd., Bangalore also have a warehouse for all critical spare parts for immediate supply to our Indian
It is clarified that the supplier
shall not have experience of
manufacture of fire and
emergency vehicles.
Page 19 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
customers. Moreover, this clauseblatantly favoring only one bidder in India and restricts a healthy competition in this global tender.
4. Section VI A of Qualification Criteria Point B (Page 47): The said clause says “at least one performance certificate of same model offered of 55 meters”. As mentioned above, we have not supplied the 55 meter TTL in India and hence would not be able to give this certificate. As mentioned earlier , we have supplied one 62 meters TTL which was commissioned in January 2015.However we have the performance certificate for 32 meters,39 meters and 42 meters .We request you to give us exemption based on our global presence and our lateral entry in India.
It is clarified that the manufacturer must have manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
Page 20 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
7 MORITA 1-5 Techno Park Sanda-Shi, Japan
SECTION – VI
TECHNICAL SPECIFICATIONS
SPECIFICATIONS FOR FABRICATION AND SUPPLY OF
TURNTABLE LADDER 55 METER HEIGHT FOR FIRE FIGHTING AND RESCUE
1. GENERAL REQUIREMENT
1.1 The Turntable Ladder shall be designed specifically for the purpose of fire fighting
and rescue to enable firemen to go up and down. It shall comprise of ladder
sections with a cage mounted at the end of top ladder section and a lift for going
up and down to rescue people. The entire unit shall be mounted on a Turn-Table
on a Heavy Duty powerful Diesel - Engine chassis of MAN/VOLVO / MERCEDES
BENZ /Equivalent make, 6x4 having approx. 5000 mm Wheel Base with fully
factory built cabin and suitable capacity PTO. The Vehicle Chassis shall conform
to EURO III emission norms.
1.2 The Turntable Ladder shall be designed as per the designed, operational stability
and structural strength based on the criteria laid in EN 14043 or, Japanese
safety standard or any other International standard and other norms and
standards applicable for elevated raised platforms used for Fire Fighting and
rescue operations.
1.3 The TTL shall be capable of use at any angle of elevation without any reduction of
load capacity of the cage. It shall also rotate 360 degree at any angle of elevation
Page 21 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
as well as below ground level subject to ladder remaining clear of vehicle body.
The Turntable Ladders Shall Have A Computer Controlled Oscillation Damping
System To Ensure Stable And Smooth Operation Of The Unit At Heights.
1.4 The appliance shall be compact and fast on the road and easily maneuverable in
the crowded streets and around sharp corners. The overall dimensions shall not
exceed the limits specified herein.
1.5 The height of the Turntable Ladder when fully extended shall not be less than 53
mtrs to the cage bottom from the ground.
1.6 The Turntable Ladder shall be micro processor based electro hydraulically
controlled, permitting precise and easy operations under the most difficult
conditions, with ample reserve of strength and stability.
1.7 Full safety interlocks shall be incorporated in the design so as to ensure complete
safety in operations and long years of reliable and trouble free service, as far as
possible the system shall be fail proof.
1.8 The design of the TTL shall allow a very large safety margin for extreme operating
and climatic conditions. The safe working loads ratings shall include an allowance
for the weight of water system and the reaction from the monitor jet while
operation.
Page 22 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
1.9 The Vehicle shall have a leveling system to adjust an angle not less than 7 degree
and it shall be in automatic in nature with the manual override in case of
emergency.
1.10 There shall be a full back up system for all ladder movements and outrigger
movement in case of failure of main system. This shall be achieved with the help
of electro-hydraulic pump (220 or 380 Volt) powered by the vehicle generator.
1.11 The Complete Movement of the TTL shall be computer controlled and stabilized
and the system shall be checked for interference sensitivity according to
standards.
1.12 The Control system of the TTL shall be fully tropicalized and able to operate in the
temperature range up to +55 degree centigrade and in a dusty and Humid
condition without reducing the maximum operating limits.
1.13 The elevation of ladder shall be possible from –10 + 75 degree.
2. CHASSIS
2. 1 The Chassis shall be either MAN/VOLVO / MERCEDES BENZ /Equivalent make, 6x4
having approx. 5000 mm Wheel Base with fully factory built cabin and suitable capacity
PTO. The Vehicle Chassis shall be a Right Hand Drive and shall conform to EURO III
emission norms.
Page 23 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
2.2 The Chassis shall be homologated from the appropriate authority in India in case
not an approved model.
2.3 The engine shall be six cylinder, Diesel with direct injection, turbo charged with
intercooler.
2.4 The engine shall develop maximum 400 HP.
2.5 The gearbox shall be automatic transmission type.
2.6 Rear Axle shall be Tandem Bogie type with Hub reduction and differential lock
between the wheels and axles.
2.7 Chassis frame shall be 'C' Channel section made of high strength steel with cross
members.
2.8 The Steering shall be integral power steering with fully adjustable steering wheel
and column.
2.9 The Front and the rear Suspension shall be leaf spring type.
2.10 The Brakes shall be dual circuit airbrakes, with parking brakes acting on rear
wheels.
Page 24 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
2.11 Fuel Tank - Capacity shall be min 300ltrs with lockable fuel cap.
2.12 The Chassis shall be provided with 10 Tyres – plus spare tyre of suitable size as
per GVW of vehicle.
2.13 The chassis shall be provided with single cab with RED RAL 3000 colour, made
from high strength steel fully trimmed, external panels hot dip galvanized with
hydraulic cab tilting mechanism. The cab shall be provided with adequate
ventilation, rear view mirrors, windscreen glasses and windows, adjustable driver
seat, wiper system and along with all other standard fitments.
2.14 The Electrical system shall be 24V, with suitable capacity batteries & Alternator for
charging the batteries.
2.15 The chassis shall be supplied with standard tool kit, hydraulic jack, operator &
workshop manuals.
2.16 The Chassis shall be fitted with suitable capacity Power Take Off Unit to drive the
hydraulic pump for ladder movements.
2.17 The Chassis shall be directly procured by the tenderer confirming to above. The
Transportation responsibility of the chassis up to tenderers manufacturing facility lies
Page 25 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
with the tenderer. The Chassis shall be insured while in transit.
2.18 The quoted model of Chassis shall be homologated in India. Quoting of Non
Homologated models shall make the offer liable for rejection straight away. The bidder
must have supplied the quoted model in India on the same chassis to other fire
brigade in India.
2.19 The GVW of the quoted model must strictly comply with the CMVR Rules. Excess
weight shall not be permitted.
.3 OPERATING REQUIREMENTS & DIMENSIONS OF FINISHED APPLIANCE
The Vehicle shall comply the following requirements:
3.1 Max working Height : 55 mtrs
3.2 Height to working cage bottom :53-55 mtrs
3.3 Working outreach with 270kg cage load :16mts to 18 mtrs
It is clarified that the condition no.3.3 in the tender document has been modified and may read as “Working outreach with 270kg cage load :16mts to 18 mtrs”
Page 26 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
3.4 Rotation - Continuous : 360 degree
3.5 Safe working load in the cage on hard level Ground with dry monitor:270 Kg
Minimum
3.6 Safe working load with monitor in the cage Delivery up to 1800 LPM:90 kg to 180
kg
3.7 Loading capacity of lifting eye under the First ladder set : 2000 Kg
Minimum
3.8 Operations at maximum outreach with
Full working load permitted in wind speed upto : 12.0 Mtrs/ Sec.
3.9 The unit will be suitable for test at the load : 405 Kgs to 450 Kg hard level ground
3.10 Operating time at full stroke for all operations: As per EN 14043 or other 3.11 Overall length in traveling position less than :12mtrs minimum standard 3.12 Overall width of the vehicle : 2.50 mtrs max
3.13 Overall Height in traveling position : 3.95 to 4.1 mtrs max
3.14 Maximum width of the vehicle when
Jacks are fully extended on both sides not more than: Upto 5.5 mtrs
3.15 Gross Vehicle Weight : 25 tons-30 tons max
It is clarified that the condition no.3.6 in the tender document remain unchanged.
Page 27 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
.
CONSTRUCTION
The vehicle shall be robust in construction; materials used in construction shall be
carefully selected for lightness and durability. Use of timber shall be restricted in
bodywork and use of rubber shall be avoided as far as possible. Ferrous metal
parts shall be treated for anti - corrosion by a method other than electro-plating.
5. LADDER SET
5.1 The vehicle shall perform the following functions/ operations
5.1.1 Elevation
5.1.2 Depression
5.1.3 Extension & housing
5.1.4 Rotation 360 degree continuously in either direction
5.2 All the operations shall be electro-hydraulically operated with the help of hydraulic
cylinders, & chain etc. The system shall be purpose built to provide smooth
takeoff, variable speed range and smooth slowdown, based on the criteria laid
down under EN 14043 or any other relevant standards applicable for these kind of
vehicles.
Page 28 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
5.3 There shall be Five/six ladder Sections, with telescopic movement made from high
grade, corrosion resistant steel and shall have minimum wind catching area. The
ladder sections shall be extended and retracted telescopically and simultaneously.
Wind sensor to measure the wind speed shall be installed at the ladder tip with
waning signal sent to the main control stand when wind speed exceeds safe
operation conditions.
5.1 Based on the selected outrigger position and cage load, the system selects
automatically the maximum outreaches to all directions. The system capacity shall
enable various outreach curves for each direction. The size of each sector shall
automatically be defined based on position of outriggers. The outreach control
system shall practically be infinitely variable.
5.2 The lower ladder section shall be screwed to turret. The ladder sections shall be
welded construction; welding method shall be of latest technology to provide high
durability and extreme accuracy. For high strength and minimum flexing of the
ladder sections only high tensile strength steels shall be used.
5.3 The ladder elevation and lowering shall be controlled by two hydraulic cylinders
that both have their separate safety devices and can alone carry the entire load in
case of failure of any one of the cylinders.
5.4 All ladder sections shall move in a synchronized way and there shall not be any
intermediate jerks during extension / retraction. Automatic slowdown mechanism
Page 29 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
at the beginning of the movement as well as end of the movement shall be
provided to all ladder movements. All the moving sections shall be fitted with
adjustable guides/ rollers to provide smooth and accurate movement. Various
maintenance points shall be located well at hand either outside the ladder or
behind easily removable covers.
5.5 The extension and retraction wire ropes shall be so laid; it should not cause any
hindrance for climbing to a fireman. The ladder rungs shall be Anti Skid design
and extension and retraction cables shall be provided with tension adjustment
mechanism.
5.6 The ladder shall be possible to elevate from –10 to +75 degree minimum angle.
The rotation movement shall be continuous through 360 degree at all angle of
elevation except for the cabin protection area. In driving condition, the ladder set
shall be placed on the ladder head rest.
5.7 All the sliding sections shall have maintenance free Nylon/Steel rollers for sliding
movements and means shall be provided for the lubrication of these rollers at an
easily accessible position.
5.8 Hook On type additional ladder or fixed shall be provided for the access to main
ladder assembly from the ground. A lifting eye shall be provided at the head of the
main ladder section to lift the load.
Page 30 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
5.9 An attachment system shall be provided at the top of ladder and in cage for fixing
water monitor. The monitor attachment shall be quick connecting type without the
use of bolts and nuts. The monitor can be kept at some other suitable place on the
vehicle. Or fixed type monitor .
5.10 All main ladder movements shall be possible individually and simultaneously.
While using simultaneous movements there shall not be reduction in the speed of
ladder movements. The ladder leveling (plumbing) movement shall be automatic
in nature.
5.11 All the ladder movements except rotation, just before reaching the limit shall
slowed down automatically until rest. In addition to this, the ladder lowering rate
shall proportionally be decrease with increasing ladder length in order to avoid
excessive swinging of ladder tip when ladder movement stops.
5.12 The functional, ergonomically designed main operating control consol shall be
provided on the left hand side of turntable, with suitable operator seat. The
following controls shall be provided on main control.
5.15.1 Lever / Joy stick for rotation and elevation and depression.
It is clarified that the condition no. 5.9 in the tender document has been modified and may read as “ An attachment system shall be provided at the top of ladder and in cage for fixing water monitor. The monitor attachment shall be quick connecting type without the use of bolts and nuts. The monitor can be kept at some other suitable place on the vehicle. Or fixed type monitor.”
Page 31 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
5.15.2 Lever / Joy stick for extension and retraction.
5.15.3 Foot pedal for oil pressure ON/OFF (Dead Man type switch)
5.15.4 Button for engine Start/Stop or emergency stop.
5.15.5 Button for ladder leveling (Plumbing) ON/OFF. Or automatic leveling .
5.15.6 Button/sign for rungs in alignment.
5.15.7 Button for One man/Two man/Three man selection/five man selection.
5.15.8 Button for lighting ON/OFF.
5.15.9 Button for emergency stop.
5.15.10 Volume control for main control stand speaker and speaker at ladder top.
It is clarified that the condition no. 5.15.5
in the tender document has been
modified and may read as “Button for
ladder leveling (Plumbing) ON/OFF. Or
automatic leveling” .
It is clarified that the condition no. 5.15.6 in the tender document has been modified and may read as “Button/sign for rungs in alignment.” It is clarified that the condition no. 5.15.7 in the tender document has been modified and may read as “Button for One man/Two man/Three man selection”
Page 32 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
5.15.11 Microphone for intercom system.
5.15.12 Lever for emergency operation ladder and jacks.
5.15.13 Graduated Arc with pendulum.
5.15.14 Button for automatic housing of ladder in the head rest.
5.15.15 Display screen
5.16 The ladder set shall be primed and painted for long life span, treated against rust
and corrosion.
6. HYDRAULIC CYLINDERS
6.1 The Hydraulic cylinders shall be double acting, fitted with lock valves so as to
prevent ladder set, working cage from lowering or the outriggers from retracting in
case of pipe or hose failure.
6.2 The cylinders shall be provided with automatic dampers to prevent the pressure
shocks and shall dampen the movement when a mechanical stop is reached.
6.3 Retraction of the outriggers shall be automatically prevented as soon as the
ladder set has been lifted up from their transport position by way of electrical OR
Hydraulic interlock system.
6.4 The ladder elevation and lowering has to be controlled by two hydraulic cylinders
Page 33 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
that both have their separate safety devices and both can alone carry the entire
load in case of failure of any one of the cylinders.
6.5 The piston rods of the outrigger cylinders shall be protected suitably in order to
protect piston rod from damage caused by any external impacts.
6.6 Lifting of the ladder set from the transport position shall be prevented before the
outriggers are in support position and there shall be a limiting circuit to prevent
damage to the Drivers cabin when the ladder is not clear of the cabin.
6.7 All the movements shall be automatically limited in their extreme position and the
working cage shall be prevented from working outside of the permitted working
range in any position.
6.8 An emergency stop switch shall be provided on both control panels, which shall
switch off the hydraulic pressure of all movements only or shall stop the vehicle
engine also.
It is clarified that the condition no. 6.8 in
the tender document has been modified
and may read as “An emergency stop
switch shall be provided on both control
panels, which shall switch off the
hydraulic pressure of all movements only
or shall stop the vehicle engine also. “
.
Page 34 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
7 TURN-TABLE
7.1 The turntable shall be fully integrated steel structure containing center post, slip
rings, etc duly fastened to the main frame by means of slewing ring.
7.2 The rotation for the turntable shall be controlled by hydraulic motor with brakes.
7.3 The base control station shall be attached to the turntable so as to rotate with it
and be accessible in all positions of the turntable.
7.4 The hydraulic distributor (center post) shall be mounted in the center of the
turntable at an accessible position and shall carry the hydraulic pressure and
return lines, electrical supply lines allowing continuous rotation in either direction.
7.5 The fasteners retaining turntable to the rotation mechanism shall be of proper
grade and shall be torque properly.
7.6 The rotation gearbox fastener shall be of proper grade and torque with proper
backlash.
7.7 Pins securing the hydraulic cylinders shall be properly installed and secured.
7.8 The hydraulic hoses, tubing’s and connections provided in the turntable shall be
free from kinks, chaffing or leaks.
Page 35 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
8. STABILISING / JACKING SYSTEM
8.1 The Jacking system shall consist of hydraulically operated four outriggers
mounted in their housings. Each housing shall be fitted with adjustable guides to
provide smooth and accurate movement of the outrigger beam. The outrigger
piston rods shall be completely protected by closed steel profile.
8.2 The Jacks shall be diagonal type or H type configuration, each side shall have
two separate stabilizers. This is to ensure that the jacks can be extended even
when the vehicles are parked on narrow by lanes close to the unit. This will also
ensure that it would be easier for the fire crew to walk over the jacks even when
fully extended.
8.3 The jack shall be provided with ground pressure sensors, which shall be correctly
actuated before the ladder set is operated to ensure proper stabilization.
It is clarified that the condition no. 8.2 in the tender document has been modified and may read as “The Jacks shall be diagonal type or H type configuration, each side shall have two separate stabilizers. This is to ensure that the jacks can be extended even when the vehicles are parked on narrow by lanes close to the unit. This will also ensure that it would be easier for the fire crew to walk over the jacks even when fully extended.”
Page 36 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
8.4 Each inclined/vertical jack shall be provided with self-aligning footplate to spread
the load evenly and allow the operation on uneven ground.
8.5 The system shall be able to level the vehicle up to 7 degree sideways and with
automatic leveling system.
8.6 The jacking system shall be controlled by two separate control panels provided on
left and right side of the vehicle at rear with following controls.
8.6.1 Left side front and rear outrigger beam out.
8.6.2 Right side front and rear outrigger beam out.
8.6.3 Left side jacks down
8.6.4 Right side jacks down.Or Jacks are down by one switch for all 4 jacks.
8.6.5 Automatic axle locking mechanism may be provided by.
8.6.6 Cage folding in isolation switch.
8.6.7 Vehicle leveling gauge
8.6.8 Emergency stop push button
It is clarified that the condition no. 8.5 in the tender document has been modified and may read as “The system shall be able to level the vehicle up to 7 degree sideways and with automatic leveling system.” It is clarified that the condition no. 8.6.4 in
the tender document has been modified
and may read as “Right side jacks
down.Or Jacks are down by one switch
for all 4 jacks.”
Page 37 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
8.7 All the jack movements shall be infinitely variable within the full jacking width.
8.8 The Jacking systems shall allow operating each jack individually and the jack
projection shall be recognized by the controlling system and the maximum
outreach shall automatically be calculated as per the jack width.
8.9 The jacks shall be controlled individually or in pair with lever /joystick and the
control panel shall be situated in such a position that, the operator will have clear
look to the right and left hand side while extending the jacks. The control panel
shall be located at the rear side of the vehicle.
8.10 Yellow Flashing warning lights shall be provided at the outer most point of the
jacks to identify the position of the jacks during night operation.
8.11 Four wooden spreader plates shall be provided for the use, when the vehicle is to
be operated on soft ground.
8.12 The stabilizing system shall also preferably incorporate axle-locking mechanism.
8.13 The locker containing outrigger controls shall be fitted with an automatically
operating door switch and a light for night operation.
Page 38 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
9 ELECTRONIC SAFETY AND OUTREACH SYSTEM
9.1 The computer-controlled and stabilized system shall allow the outriggers to be
positioned and the system shall be capable to select automatically the maximum
allowed outreach to front, rear, right and left side. Based on calculations and
parameters saved in the system to guarantee exactly the same outreach
regardless of the external influences like wind speed and direction, temperature,
friction of the cylinders, etc.
9.2 The display units of the system shall show maximum possible outreach and
position of the working cage in real-time along with other details.
9.3 The electronic system shall be made in CAN-BUS technology and approved
according to the valid standards and directives. The system shall be EMC tested
(EU directive 89/336/EEC) and CE type tested by TUV or any other appropriate
agency.
10. CAGE & LIFT
10.1 The working cage shall be fix in case of detachable cage.The working cage shall
be attached to the tip of top section and it shall be foldable. There shall be
sufficient space for three persons and safe working load shall not be less than 270
kgs. excluding the equipment permanently mounted in the cage. The leveling of
Page 39 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
the cage shall be controlled automatically by an electro/hydraulically mechanism
with manual override in case of emergency. The controls for folding over and in
working position shall be integrated into the control panel for the jacking system.
The entrance to the cage shall be provided from the front and rear.
10.2 The cage shall be made of tubular Steel/Aluminum profile, welded together and
painted with special paint with high durability in case of steel cage. The
dimensions of the working cage shall be such that it shall provide sufficient space
for three men. The top railing shall be part of the cage door so that entering into
the cage without bending is possible.
10.3 The cage shall be designed for 270 Kgs working load and shall be tested for min.
50% overload capacity.
10.4 In case of detachable case.The cage shall be quick removable type whenever
needed.
10.5 An emergency cage leveling operation shall be provided in case of failure of
electricity by means of Hand / Foot pump.
10.6 The cage control shall allow all ladder movement to be performed infinitely
variable. During cage operation, the movement shall be automatically controlled
by the safety system. When the ladder is operated from the cage, the speed of
movements shall be the same as ladder control from main control consol.
Page 40 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
10.7 The location of cage control shall be such that the operator shall have clear look
on all side when operating the ladder from the cage. The Joy stick/Levers in the
cage shall be identical that of the main console. The cage control panel shall
always be visible and accessible, even when the additional equipment is used by
the fireman. One xenon flood light shall be provided in front of the cage for
illumination during night operations.
10.8 The cage control shall have following controls on the control panel.
10.8.1 Lever/joy stick for rotation and elevation and depression.
10.8.2 Lever/Joy stick for extension and retraction.
10.8.3 Foot pedal for oil pressure ON/OFF (Dead Man type switch)
10.8.4 Button for engine Start/Stop or emergency stop.
10.8.5 Button/sign for rungs in alignment.
10.8.6 Button for One man/Two man/Three man selection/five man selection.
10.8.7 Button for lighting ON/OFF.
10.8.8 Button for emergency stop.
It is clarified that the condition no. 10.8.5 in the tender document has been modified and may read as “Button/sign for rungs in alignment.” It is clarified that the condition no. 10.8.6 in the tender document has been modified and may read as “Button for One man/Two man/Three man selection.”
Page 41 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
10.8.9 Button for automatic housing of ladder.
10.8.10 microphone-cum-speaker for intercom system.
10.8.11 Operation display screen.(LCD)
10.8.12 Button for cage light ON/OFF.
10.9 Wide angle fixed video camera shall be installed on the cage front with image
transmission to the main control stand display.
10.10 All ladder movements shall be stop automatically when the cage collusion system
is activated.
10.11 A rescue lift shall be mounted at the rear of ladder set to be used for fast
emergency rescue operation. Lift shall be use at any ladder rotation angle and
also when cage is mounted at ladder tip.
10.12 Rescue lift capacity shall be not less than 180 Kg.
10.13 Lift shall be controlled either by main control stand or from the lift by means of
wireless remote control system. Access to the lift shall be possible at the rear of
the vehicle from the ground due to extended rails to lower the lift near to ground
level or through the fixed stop to the platform.
Page 42 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
11 HYDRAULIC SYSTEM
11.1 The Hydraulic power shall be provided by a reliable & adequate capacity variable
displacement axial piston pump, which shall be driven by the vehicle power take
off.
11.2 When no operation of the ladder is activated, the pump shall rotate on minimum
flow and minimum pressure. When the control lever or oil pressure foot paddle is
pressed, the engine should automatically go to pre set rpm and also activate the
necessary hydraulic oil supply to all the circuits.
11.3 There shall be a provision of instant couplings for attachment of manometer in
each pressure line for checking pressure of each circuit.
11.4 The suitable filtration system of the hydraulic oil shall be provided on the vehicle to
insure a good quality of oil entering into the system.
11.5 All hydraulic cylinders shall be double acting with hard chrome plated piston rods
and shall be fastened by means of preferably self-aligning ball bearings to prevent
lateral forces from damaging the seals or piston rods of the cylinders.
11.6 Hydraulic oil tank shall be provided into the turn table or in suitable place of
suitably capacity. There shall be a proper heat dissipation system. The tank shall
It is clarified that the condition no. 11.6 in the tender document has been modified
Page 43 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
be fitted with oil level gauge, and suction connections with closing valves for easy
maintenance and draining outlet with closing valve.
and may read as “Hydraulic oil tank shall be provided into the turn table or in suitable place of suitably capacity. There shall be a proper heat dissipation system. The tank shall be fitted with oil level gauge, and suction connections with closing valves for easy maintenance and draining outlet with closing valve.”
12. BACK-UP FOR THE HYDRAULIC SYSTEM
12.1 The hydraulic power for all necessary ladder movements shall provide via a
separate electro-hydraulic pump (220 or 380 Volt or 24 VDC). The electro-
hydraulic pump shall be provided at suitably place for safe and easy operation.
12.2 There shall be a separate power generator mounted at suitable place, providing
electricity to the hydraulic pump, which will provide independent means of
hydraulic power in case of failure of main engine of vehicle. The power generator
shall be able to start from main control panel or manually.
12.3 In case of failure of main control panel system, emergency operation of all ladder
movements shall be possible. All the ladder movements shall be safely controlled
It is clarified that the condition no. 12.1 in the tender document has been modified and may read as “The hydraulic power for all necessary ladder movements shall provide via a separate electro-hydraulic pump (220 or 380 Volt or 24 VDC). The electro-hydraulic pump shall be provided at suitably place for safe and easy operation.”
Page 44 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
with hydraulic system from the main control consol.
13 CONTROLS AND SAFETY
13.1 The Electrical supply needed for control system shall be taken from the vehicle
battery which shall be charged when the engine is running.
13.2 When the vehicle is in operation yellow flashing warning lights mounted on the
outriggers shall automatically remain on.
13.3 The engine starting and stopping switch or emergency stop switch shall be
provided on all control panels and the engine speed shall be increased to the pre-
set level as soon as the foot paddle is pressed.
13.4 All boom and rotation movements shall be controlled electro-hydraulically by
means of proportional valves. The proportional valve shall not be sensitive to
changes of ambient or oil temperature, and shall provide smooth, safe and very
accurate movements even in most severe operating conditions.
13.5 The speed of the ladder for lowering and extension shall be automatically reduced
at maximum outreach. The ladder lifting speed shall be reduced before the
maximum elevation.
Page 45 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
13.6 All control movements can be performed by the control system from both control
panels and the outreach can be selected by the positioning the outriggers. The
variable system shall consist of two displays, the graphical display and real time
information about the outreach and the cage position and also to show possible
movements according to cage position by animated arrows. In the text display
there shall be main texts for:
13.6.1 Warnings
13.6.2 Emergency situations
13.6.3 Help manual
13.6.4 Fault finding system
13.7 There shall be two independent drive elements to secured the ladder set of which
each is capable of keeping the ladder in its present position during the ladder
movements.
13.8 There shall be an inter lock, only permits the ladder sets to be lifted from the head
rest and thereafter other movements are possible.
13.9 There shall be a load measuring system for stability and security of the ladder
parts. The ladder movements shall stop automatically due to projection and / or
additional load such as rescue persons, in conjunction with the jacking widths and
the actual remaining loads.
Page 46 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
13.10 An operating range display shall continuously show the total working range and
the present load situation. The position of the ladder and the load limit in
conjunction with the jacking widths shall display simultaneously.
13.11 For the stability of the ladder, the speed of all the movements shall slow down
smoothly and automatically before reaching the final position and automatically
stop all movements in the defined final position.
13.12 For the tactical requirement during the emergency operation, preferably there
shall be a system which allows the ladder to reach the operational limit beyond the
free standing limit, when the ladder head is supported against the wall.
13.13 When the ladder reaches to its operational limits. There shall be automatic final
stopping of all ladder movements except for retraction and rotation.
13.14 There shall be a driver’s cabin protection mechanism which will stop respective
ladder movement to avoid collision of ladder with cabin.
13.15 There shall be an impact cut out which will stop all ladder movements.
It is clarified that the condition no. 13.12 in the tender document has been modified and may read as “For the tactical requirement during the emergency operation, preferably there shall be a system which allows the ladder to reach the operational limit beyond the free standing limit, when the ladder head is supported against the wall.”
Page 47 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
13.16 An automatic hydraulically operated and electronically control leveling system
(plumbing) shall be active all elevation and inclination angles. It shall guarantee
that, the rounds are always horizontal up to angle of 70. The plumbing mechanism
can be switch off / on from the main control console or leveling should be
automatic.
It is clarified that the condition no. 13.16
in the tender document has been
modified and may read as “An automatic
hydraulically operated and electronically
control leveling system (plumbing) shall
be active all elevation and inclination
angles. It shall guarantee that, the rounds
are always horizontal up to angle of 70.
The plumbing mechanism can be switch
off / on from the main control console or
leveling should be automatic. “
14. OPEARTING RANGE DISPLAY
14.1 An operating range display shall be provided at main control console, and cage
control console, which shall provide information to the operator. The various
signals coming from the sensors, computer shall be processed and visually
represented in the form of text or symbol on the display.
14.2 A scale down representation of the actual available range of operation shall be
displayed showing exactly the ladder position, projection, ladder length, height
and angle of elevation.
Page 48 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
14.3 A microprocessor shall control and monitor all ladder movements and safety
system. If the safe operating limit is reached, the ladder movement shall be
blocked automatically and a corresponding massage / indicator shall be shown on
display screen.
14.4 Display shall show text massage of operational faults including its consequences.
14.5 The operating range display shall be illuminated suitably for easy reading during
the night operation.
14.6 Both the Cage and Turret Control Panel shall be COLOR DISPLAYS.
15. CONTROLS AND INDICATORS IN DRIVERS CAB
15.1 The following control and indicators shall be provided in drivers cabin.
15.1.1 Visual warning for any of the equipment lockers being open
15.1.2 Visual warning for the ladder set not being fully in transportation
position
15.1.3 Switch with visual indication for rotating beacons
15.1.4 Switch with visual indication for siren unit
15.1.5 Microphone for the public address system
Page 49 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
16 BODY WORK AND EQUIPMENT LOCKERS
16.1 The structure for the bodywork shall be made up of Aluminium profiles.
16.2 The complete external paneling of the rear body shall be made from Aluminium sheet
fitted to the structural member either by gluing or riveting.
16.3 The complete flooring of the rear deck shall be made from non skid aluminum
chequered plate of 3 mm thick properly riveted or bolted to the superstructure
members.
16.4 For the easy access to the rear deck from ground level, there shall be sufficient
numbers of recessed steps on both sides of the vehicle provided with suitable
grab handles.
16.6 Sufficient numbers of lockers shall be provided on both side of the vehicle for
keeping various accessories and equipments. The locker shall be so made that
load distribution on both sides is equal. All the lockers shall be provided with roller
shutters properly sealed for water and dust ingress. All the doors of the lockers
shall be fitted with automatic switches activating the light as soon as the door is
opened and also activating the warning light in Drivers cab.
Page 50 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
17 THE WATER MONITOR
17.1 Electrically operated monitor attached to the ladder head or in the rescue cage
shall be provided with standard 63 mm. BIS male coupling.
17.2 The output of the monitor shall not be less than 1800-2000 LPM at 10 bar and
throw range shall be approx 40 mtrs when the cage is attached and the ladder set
is elevated to 53 meters cage bottom at an angle of 75°. No reduction in the
ladder angle or height is allowed while operating the monitor at full flow.
17.1 The monitor can be moved vertically upward and downward up to -150 to + 600.
The horizontal movement up to 300 left side and right side.150 on both sides and
total 300
17.2 The monitor shall be fed through a flexible fire fighting hose pipe connected to the
ladder sets with Indian Instantaneous male and female couplings. Or monitor is
fixed type and water way pipe is telescopic.
It is clarified that the condition in the tender document remains unchanged. It is clarified that the condition in the tender document remains unchanged.
18. INTER COMMUNICATION SYSTEM
18.1 There shall be fully transistorized talk back inter communication system fitted
between turntable and the cage.
Page 51 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
18.2 The system shall be combined microphone and loudspeaker for hands free
operation and shall be located in the cage. The turntable control station is also
equipped with microphone, which shall be integrated in the loudspeaker with
volume control.
18.3 The microphone and the loudspeaker shall be sealed properly and it shall be
protected from the ingress of water, dust and humidity.
19. ELECTRIC SYSTEM
19.1 The electrical supply shall be taken from the vehicle batteries, which are kept
charged when the engine is running. Voltage of the system shall be 24 V DC and
all circuits shall be provided with specific fuses depending on the current
consumption of that circuit.
19.2 When the P.T.O. is switched on, yellow flashing warning lights located at each
outrigger and ladder set pivoting point shall automatically be switched on.
19.3 Two rotating beacon lights shall be provided on each side of the drivers cab roof
with Amber colour lens and at the rear of the vehicle on the ladder set. The switch
for switching the beacons on and off with suitable signal light shall be integrated in
the control panel of siren cum public address system. The beacon light shall be
either Bosch or Hella make.
Page 52 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
20 SIREN AND PUBLIC ADDRESS SYSTEM
20.1 There shall be an electric siren unit fitted on the roof of the vehicle cabin or at a
suitable place with the control unit mounted conveniently inside the driver cabin. It
shall have the fast (yelp) and slow (wail) sound modes with integrated switch for
rotating beacon lights.
20.2 Command microphone, which is fitted with push-to-talk switch, allows the public
address message to override the siren function. Operations are controlled by non
glare-illuminated push buttons of different colors on control panel shall be provided.
21. PAINTING
21.1 Before painting all surfaces of steel structures shall be carefully shot blasted after
which they shall be primed and then applied the coat of approved paint. All the
ladder set shall also be painted from all the sides.
21.2 For very high corrosion resistance of hollow structures such as steel profiles of the
working cage, ladder set, outrigger beams and housings shall be treated with anti-
corrosion protection preferably with “TECTYL”.
Page 53 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
21.3 The following Paint shades shall be used:
22.3.1 Working cage & ladder sets: Light grey RAL 7035/Silver
22.3.2 Ladder support, Turntable and related Cylinders: Red RAL 3000
22.3.3 Body work including cabin: Red RAL 3000
22.3.4 Chassis frame touch-ups: Chassis original tone(JSSWMMKJ)
21.4 Fire brigade name and logo shall be provided in suitable positions on the vehicle
22. ACCESSORIES
22.1 Wooden outrigger ground pads/ plates with brackets - 4 Nos
22.2 Working range diagrams, at turntable & in the cage 2 Nos
22.3 Marking of safe working load in the cage - 1 No
22.4 Unit type marked on the ladder. - 2 Nos
22.5 Warning labels and instruction plates - 1 set
22.6 Operation and maintenance manuals for TTL and Chassis. - 2 sets
22.7 Plug for 220 V power supply at the working cage - 3 No
22.8 Plug for 220 V power supply at the working cage - 1 No
22.9 Lifting hook under the first ladder set of capacity 2000 kg - 1 No
Page 54 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
22.10 Swiveling stretcher support c/w suitable folding stretcher To be installed on
the cage when needed - 1 No
22.11 Power generator 5KVA upto 8 KVA capacity 220/380 Volt - 1 No
22.12 Delivery hose 2 ½” with Indian Inst. coupling 55 m length - 2 No
22.13 Set of Tools for repairs & maintenance of unit - 1 set
It is clarified that the condition no. 22.11
in the tender document has been
modified and may read as “ Power
generator 5KVA upto 8 KVA capacity
220/380 Volt- 1 No”
SECTION VI – A QUALIFICATION CRITERIA The Bidder must satisfy conditions and submit documentary evidence as stipulated below with techno commercial bid, failing which the offer is liable to be rejected.
A. The manufacturer must have manufactured & supplied at least 25 Turn Table Ladders of of 50 to 55 meters or higher capacity during last 7 years and supplied to India minimum 3 Nos. TTL supplied in India and working satisfactory till date. The Bidder shall submit complete list of
It is clarified that the manufacturer must have manufactured & supplied at least 25 TTL of 50 meters or higher capacity during last 7 years and supplied to India
Page 55 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
supplies as well as documentary evidence in support of equipment supply and its performance certificate.
minimum 2 No. TTL and working satisfactory till date. The Bidder shall submit complete list of supplies as well as documentary evidence in support of equipment supply and its performance certificates.
B. At least one performance certificate issued by any fire brigade in India for Turn Table Ladder . This unit shall be in service with the customer for atleast 2 years from the date of opening of the bid. Documentary evidence for the same must be provided along with the bid.
At least one performance certificate issued by any fire brigade in India for Turn Table Ladder of 50 meters or higher capacity mounted on the same chassis as quoted in this tender shall be submitted along with the tender. This unit shall be in service with the customer for atleast 2 years from the date of opening of the bid. Documentary evidence for the same must be provided along with the bid.
C. The manufacturer shall be an ISO-9001 certified company. Attested copies of ISO-9001 shall be submitted in support of this condition.
D. Certificate issued by the competent third party agency as per the clause mentioned in Technical Specifications Point No: 1.2 for TTL shall be enclosed
Page 56 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
with the tender.
E. The bidder or his principal manufacturer should have their sales & service network in India directly or through their authorized agency/ representative/ distributor. To substantiate it, authorized agency/ representative/ distributor shall furnish the authorization letter in original with tender offer. The authorization should remain valid till the full contract period including supply, warranty period.
F. Technical specifications of the bid should be confirmed clause wise in total. Each clause / point has to be confirmed by the original equipment manufacturer (OEM) of the TTL. Mere one letter confirming the Technical Specifications shall not be accepted.
G. The TTL should be new and not repaired/ refurbished. The certificate to this effect should be provided by the original equipment manufacturer (OEM) of the TTL.
H. The bidder should have their authorized agency / representative / distributor which shall be manufacturer of Fire & Emergency Vehicles or 3 year experience of Arial ladder maintenance to look after the maintenance and service of the TTL. Bidder shall enclose the documentary evidence that the authorized agency / representative / distributor is manufacturer of Fire &
It is clarified that the condition in the tender document remains unchanged
Page 57 of 57
A.K.Kansal, Naresh Batta, DCFA, Avtar Singh, Surjit Singh, Commissioner, Chief Engineer, Superintending Engineer, Municipal Corporation, ADFO, ADFO, Municipal Corporation, Local Govt. Punjab. Municipal Corporation, SAS Nagar. SAS Nagar. Municipal Corporation, Patiala. Municipal Corporation, SAS Nagar. Jalandhar.
Emergency Vehicles including but not limited to NSIC Certificate or Factory License or DIC Certificate.
I. Bidder should mention clearly, the make and model of the TTL being quoted. Bidder should enclose detailed technical specification and OEM’s technical literature/ leaflets etc along with the bid.
J. The manufacturer shall enclose undertaking to ensure the availability of spares at least for 10 years.
NOTE Page no 8 clause no 14.3
14.3 The bid security shall be denominated in Acceptable Indian Currency and shall: (a) At the bidder’s option, be in the form of either a demand draft or a bank guarantee from a Indian Nationalized Bank. (b) Be substantially in accordance with one of the form of bid security included in Section VIII or other form approved by the Purchaser prior to bid submission; (c) Be payable promptly upon written demand by the Purchaser (d) Be submitted in its original form; copies will not be accepted; and (e) remain valid for a period of 30 days beyond the original validity period of bids, or beyond any period of extension subsequently requested under ITB Clause 15.
It is clarified that earnest money has to be submitted online only and No Bank Guarantee or demand draft will be accepted and this clause has been deleted from page 8 clause no. 14.3