+ All Categories
Home > Documents > Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient...

Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient...

Date post: 24-Jul-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
12
Cervical Distractor Surgical Technique
Transcript
Page 1: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

Cervical DistractorSurgical Technique

Page 2: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

Image intensifier control

This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended.

Processing, Reprocessing, Care and MaintenanceFor general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact your local sales representative or refer to:http://emea.depuysynthes.com/hcp/reprocessing-care-maintenanceFor general information about reprocessing, care and maintenance of Synthes reusable devices, instrument trays and cases, as well as processing of Synthes non-sterile implants, please consult the Important Information leaflet (SE_023827) or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance

Page 3: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

Cervical Distractor Surgical Technique DePuy Synthes 1

Table of Contents

AO Spine Principles 2

Introduction Set Composition 3

Product Information Instruments 4

Handling Instructions 6

Bibliography 9

Page 4: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

coronalaxial

sagittal

2 DePuy Synthes Cervical Distractor Surgical Technique

The four principles to be considered as the foundation for proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment – Biology – Function.1,2

StabilityStabilization to achieve a specifi c therapeutic out-come

BiologyEtiology, pathogenesis, neural protection, and tissue healing

AlignmentBalancing the spine in three dimensions

FunctionPreservations and resto-ration of function to pre-vent disability

AO Spine Principles

Copyright © 2012 by AOSpine

1 Aebi et al (1998)2 Aebi et al (2007)

Page 5: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

Cervical Distractor Surgical Technique DePuy Synthes 3

Set Composition:187.780 Instrument Set for Cervical Distractors

Item no. Units

687.780 Vario Case for Cervical 1 Distractors size ½, with Lid, without Contents, including:

687.780.001 Bottom, size ½, for Vario Case No. 687.780

687.781 Lid, size ½, for Vario Case No. 687.780

Introduction

Page 6: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

396.395

396.396

396.967

396.970

396.971

4 DePuy Synthes Cervical Distractor Surgical Technique

Instruments

Item no. Units

396.395 Cervical Distractor, left, 1 with adjustable angle

396.396 Cervical Distractor, right, 1 with adjustable angle

396.967 Screwdriver, hexagonal, 1 length 200 mm, for Screw for Cervical Distractor

396.970 Screw B 2.7 mm, length 14 mm, 2 for Cervical Distractor, Stainless Steel

396.971 Screw B 2.7 mm, length 16 mm, 2 for Cervical Distractor, Stainless Steel

Product Information

Page 7: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

311.440

396.968

Cervical Distractor Surgical Technique DePuy Synthes 5

Optional

Item no. Units

311.440 T-Handle with Quick Coupling 1

396.968 Drill Bit B 1.8 mm, length 132/12 mm, 1 for Cervical Distractor, for Quick Coupling

Additionally available

687.780.001 Bottom, size ½, for Vario Case No. 687.780 (automatically included when ordering no. 687.780)

687.781 Lid, size ½, for Vario Case No. 687.780 (automatically included when ordering no. 687.780)

Page 8: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

6 DePuy Synthes Cervical Distractor Surgical Technique

The following handling instructions for the Synthes Cer-vical Distractor are intended for illustration of the basic functioning of these instruments. For further information about the surgical steps, please consult the respective surgical technique(s).

To insert the 2.7 mm Screws for Cervical Distractor (396.970 or 396.971), mount them on the self-holding, hexagonal Screwdriver for Cervical Distractor (396.967).

Should insertion prove difficult, pre-drill a hole for the screws using the 1.8 mm Cervical Drill Bit (396.968) mounted on the T-Handle with Quick Coupling (311.440).

Place the left Cervical Distractor (396.395) or right Cervical Distractor (396.396) over two of the 2.7 mm Screws (396.970 or 396.971). The distractor fits the screws loosely to facilitate placement and removal, and is not meant to lock on the screws.

Handling Instructions

Page 9: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

2

1

Cervical Distractor Surgical Technique DePuy Synthes 7

To allow ease of placement of the cervical distractor over the screws for cervical distractor regardless of their ori-entation, ensure that the angle-setting tab (1, below) of the cervical distractor is initially unlocked.

Once positioned on the screws, push the angle-setting tab (1) (left) to the locked position (2, below) to ensure parallel distraction of the two screws.

Even with a locked angle-setting tab (2), the distractor still allows variable angulation in one plane to accommo-date different patient heights.

Page 10: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

4

3

8 DePuy Synthes Cervical Distractor Surgical Technique

Achieve distraction between the two screws by turning the distraction tab (3) in a clockwise direction. The dis-traction can be adjusted by turning the distraction tab (3) counterclockwise, or released by pressing and hold-ing the release tab (4).

After removal of the cervical distractor, remove the screws using the selfholding hexagonal Screwdriver for Cervical Distractor (396.967).

Handling Instructions

Page 11: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

Cervical Distractor Surgical Technique DePuy Synthes 9

Aebi M, Arlet V, Webb JK (2007) AOSPINE Manual (2 vols), Stuttgart, New York: Thieme

Aebi M, Thalgott JS, Webb JK (1998) AO ASIF Principles in Spine Surgery. Berlin Heidelberg New York: Springer

Bibliography

Page 12: Surgical Techniquesynthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · proper spine patient management underpin the design and delivery of the Curriculum: Stability – Alignment

0123

Synthes GmbHEimattstrasse 34436 OberdorfSwitzerlandTel: +41 61 965 61 11Fax: +41 61 965 66 00www.depuysynthes.com ©

DeP

uy S

ynth

es S

pine

, a d

ivis

ion

of S

ynth

es G

mbH

. 201

7.

All

right

s re

serv

ed.

036.

000.

715

DS

EM

/SP

N/0

717/

0708

08

/17

Not all products are currently available in all markets.

This publication is not intended for distribution in the USA.

All surgical techniques are available as PDF files at www.depuysynthes.com/ifu