2
newterra.com SVE/AS, 100 ACFM, 34 SCFM, Container Application Soil vapor extraction and Air sparging applications Equipment Summary 4-leg vapor extraction manifold Steel vapor liquid separator w/ manual drain SVE: High-Flow, Med-Vacuum Rotary lobe blower SPARGE: Rotary vane compressor 4-leg sparge manifold Programmable Logic Controller (PLC) based control panel Construction Compact design - Installed in a 8’ x 10’ used shipping container Process piping is galvanized steel and PVC Process Specifications Rated Vacuum and Flow for Vapor Extraction System: 100 ACFM @ 60 “WC Rated Pressure and Flow for Air Sparge System: 34 SCFM @ 10 PSIG Rated Water Process Flow Rate: Optional Rated Water Discharge Pressure for Downstream Pumping Locations: Optional Approximate Weight: 6,500 lbs Approximate Exterior Dimensions: 8’ x 10’ Acceptable Ambient Temperature: 5 to + 35 ºC (40 to 95 ºF) Power Specifications • Power Requirements: 65 Amps @ 208V 3 Ph • Service Required: 100 Amps @ 208V 3 Ph • Main Disconnect by: newterra Area Classification of Process Equipment: General Purpose Area Classification of Control Panel: General Purpose, Outdoors Electrical Approvals: UL Panel Approval Telephone Line Requirements: None - Optional wireless telemetry available Standard Features Lighting, ventilation fan • Framed wall construction • Painted plywood walls, ceiling and floor Automated PLC control system for independent operation Optional Features Sound Attenuation Package: Standard and custom options available Cold weather Package: Heated and insulated for cold environment Skid Package: Equipment skid mounted only, no enclosure Mobile Treatment Package: Equipment mounted in mobile, enclosed trailer Custom Exterior Finishing Available: Siding (vinyl or steel), brick veneer Remote Access Package: Telemetry hardware with data-logging functions Customization of manifolds, blower model/HP, compressor model/HP Additional transmitters and other process instrumentation Condensate treatment options for collected condensate in separator Vapor treatment options (heat exchanger may need to be added) • Variable Frequency Drive (VFD) for motors • Hazardous (Class 1 Division 2) Area Classification Design
Transcript
Page 1: SVE/AS, 100 ACFM, 34 SCFM, Container · newterra.com SVE/AS, 100 ACFM, 34 SCFM, Container Application • Soil vapor extraction and Air sparging applications Equipment Summary •

newterra.com

SVE/AS, 100 ACFM, 34 SCFM, Container

Application• Soil vapor extraction and Air sparging applications

Equipment Summary• 4-leg vapor extraction manifold• Steel vapor liquid separator w/ manual drain• SVE: High-Flow, Med-Vacuum Rotary lobe blower• SPARGE: Rotary vane compressor• 4-leg sparge manifold• Programmable Logic Controller (PLC) based

control panel

Construction• Compact design - Installed in a 8’ x 10’ used shipping

container• Process piping is galvanized steel and PVC

Process Speci� cations• Rated Vacuum and Flow for Vapor Extraction System:

100 ACFM @ 60 “WC• Rated Pressure and Flow for Air Sparge System:

34 SCFM @ 10 PSIG• Rated Water Process Flow Rate: Optional• Rated Water Discharge Pressure for Downstream Pumping

Locations: Optional• Approximate Weight: 6,500 lbs• Approximate Exterior Dimensions: 8’ x 10’• Acceptable Ambient Temperature: 5 to + 35 ºC (40 to 95 ºF)

Power Speci� cations• Power Requirements: 65 Amps @ 208V 3 Ph• Service Required: 100 Amps @ 208V 3 Ph• Main Disconnect by: newterra• Area Classi� cation of Process Equipment: General Purpose• Area Classi� cation of Control Panel: General Purpose,

Outdoors• Electrical Approvals: UL Panel Approval• Telephone Line Requirements: None - Optional wireless

telemetry available

Standard Features• Lighting, ventilation fan• Framed wall construction• Painted plywood walls, ceiling and � oor• Automated PLC control system for independent operation

Optional Features• Sound Attenuation Package: Standard and custom options

available• Cold weather Package: Heated and insulated for cold

environment• Skid Package: Equipment skid mounted only, no enclosure• Mobile Treatment Package: Equipment mounted in mobile,

enclosed trailer• Custom Exterior Finishing Available: Siding (vinyl or steel),

brick veneer• Remote Access Package: Telemetry hardware with

data-logging functions

• Customization of manifolds, blower model/HP, compressor model/HP

• Additional transmitters and other process instrumentation• Condensate treatment options for collected condensate in

separator• Vapor treatment options (heat exchanger may need to

be added)• Variable Frequency Drive (VFD) for motors• Hazardous (Class 1 Division 2) Area Classi� cation Design

Page 2: SVE/AS, 100 ACFM, 34 SCFM, Container · newterra.com SVE/AS, 100 ACFM, 34 SCFM, Container Application • Soil vapor extraction and Air sparging applications Equipment Summary •

1.800.420.4056 | 613.498-1876newterra.comS

VE

/AS

-101

6

SVE/AS, 100 ACFM, 34 SCFM, Container

System LayoutProduct Features

Performance Data

Soil Vapor Extraction Blower: Sutorbilt 2L W/ 3 HP Motor

Side Man Doorfor Easy Access

InteriorCladding

InteriorCladding

InteriorCladding

Framed Wall Construction

Solid Plywood Interior Cladding

Painted Walls, Ceiling & Floors

Air Sparge Blower:Becker KDT 3.60 W/ 5 HP Motor

Painted Exterior

Optional insulaton for Cold Climates


Recommended