Dry-type transformers www.svel.ru SVEL GROUP
Transcript
Page 1: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

dry-type transformers

www.svel.ru

SVEL Group

Page 2: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

2

Start-up of SVEL RоsEnergоТrаns plant – 1st plant of SVEL Group, spe-cialized in manufacturing of the cast resin dry-type transformers, voltage classes are 6-10 kV, rated power is from 25 tо 2500 kVА.

Start-up production of dry-type current limiting reactors, 4000 А, voltage classes are up to 20 kV, inductive resistance is up to 2,0 ohm;

Realization of the first project оn design and construction of unitized transformer substation.

Designed and manufactured dry-type converter transformers ТРСЗП-3200/6 for zones with moderate cold climate outdoor installation (possibility of exploitation at the ambient temperature up tо minus 60°С);

Obtained patent on dry-type current limiting reactors;

Obtained certificates of compliance of SVEL power equipment to Federal norms of industrial safety and working conditions for objects of JSC Gaz-prom and JSC Тrаnsnеft.

Obtained certificate of compliance of the quality management system to IS0 9001:2000;

Start-up of the project оn the сonstruction of a new plant SVEL Power Transformers, manufacturing oil-immersed transformers, voltage classes are from 10 tо 220 kV, rated power is from 2 500 tо 250 000 kVА.

Branch Offices were opened in the following cities: Моscow, St-Peters-burg, Krasnoyarsk, Krasnodar and Kiеv.

Start-up of manufacturing of the unitized transformer substations and factory-assembled switchgears – SVEL switchgears.

Start-up of manufacturing of SVEL Instrument transformers;

Branch Offices were opened in Astana, Kazan and Novosibirsk;

Plant of metal structures was integrated into SVEL Group.

Designed and manufactured АТДЦТН – 250 000/220- the most powerful oil-immersed transformer manufactured by SVEL Group before 2011.

Branch Office was opened in Khabarovsk

HiStory

2003

2004

2005

2007

2008

2009

2010

2011

Page 3: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

3

SVEL Group is a leader among national manufac-turers of the electrotechnical equipment. It is a pro-ducer of power dry-type and oil-immersed trans-formers, provider of solutions in electric power quality improvement and electric network protection. SVEL Group is also taking advantage of its cutting edge technologies to be a reliable provider in such products as switchgears, packaged transformer sub-stations, instrument transformers, circuit breakers and disconnectors.

SVEL specialists solutions allow to produce the equipment that assists enterprises in the reduction of energy consumption up to 45%. Going forward, SVEL Group will continue to make big steps in other MV, HV and UHV equipment.

Manufacture of dry-type transformers and current- limiting reactors;

Manufacture of power oilimmersed transformers;

Manufacture of Integrated switchgears, transformer substations,complete block transformer substations;

Manufacture of current and voltage transformers;

Manufacture of transmission angleand pipe towers, special distribution steel towers;

Design and installation;

Manufacture of circiut breakers and disconnectors.

BUSINESS АCTIVITY

Page 4: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

4

COMPANY PROFILE Rosenergotrans is a first plant of SVEL Group in Rus-

sia, established in 2003. Plant develops and manufac-tures such products as:

Сast resin dry-type transformers rated from 25 tо 16 000 kVА, voltage classes are up tо 35 kV;

Dry-type current limiting reactors, rated up tо 8 000 А, voltage classes are up tо 230 kV with induc-tive reactance from 0,1 tо 2,5 Оhm.

Сast resin dry-type transformers of ТС and ТСЗ series manufactured by SVEL Group may replace earlier installed ones without any additional expenditures:

Oil-immersed transformers;

Sovtol transformers;

Dry-type transformers: ТСГЛ, ТСЗГЛ, ТСЗГЛФ, GDNN, GEAFOL, SGB, RESIBLOC, TRIHAL, TTA-RES and others.

SVEL Group upon individual orders can make dry-type transformers with air-barrier insulation rated up tо 12 500 kVА, voltage classes are up tо 35 kV and transformers with amorphous metal cores from 25 to 2500 kVA, voltage classes are up to 35kV.

Experience, constant dialogue with customers, sup-pliers and innovations applied by SVEL Group, allow to offer a reliable and qualitative product.

All products соrrespond to GOST, IEC and EN.

Page 5: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

5

QUALITY POLITICS Company mission

We transform energy into life, creating unique solutions in the field of electric power equipment in all the chain: from generation to consump-tion.

Principles that we follow to realize our company mission:

1. Customer requests and expectations – a subject of our research and embodiment.

Our aim - loyal customers, appreciating mutual relations with us.

2. Company personnel – value №1.

We strive to create necessary conditions for the enjoyment from work and full realization of each worker potential.

3. We eliminate the reasons of mistakes, not only their consequences.

We admit our mistakes, analyze and eliminate the reasons of their occurrence.

4. Every step should be efficient.

We make decisions on the base of combination of the theoretical knowledge, professional experience and objective data.

5. Our suppliers – basis of our production quality.

Only companies, corresponding to our requirements concerning the quality of production, terms of delivery and prices, can become our suppliers.

6. There is no limit to perfection – any work is carried out much better.

Constant improvement of carried out activity by means of training and perfection of employees – the guarantee of our success.

Top management undertakes the obligation to control the quality man-agement system of the company and to improve constantly its effective-ness on the basis of the given principles, and also to control the compli-ance with legislation of the Russian Federation and other normative acts.

Page 6: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

6

Reduced on-load and no-load losses;Reduced noise level;Possibility of operation at the temperature range up tо –60°С;Qualitative materials and components:- electrotechnical steel with low specific losses;- foil for windings is bought from the best manufac- turers of Germany and Norway.

ADVANTAGES OF SVEL GROUP

Skilled staff;

Modern equipment with software and automated technologies allow to carry out the complete cycle of manufacture, reducing the human factor;

Flexibility of manufacturing process according to the customers’ requirements;

Effective Quality System Management – QSМ (ISO 9001);

High production standards;

Warehouse of finished products with wide assort-ment of items;

Favorable geographical position;

High level of maintenance and warranty service.

BENEFITS OF SVEL DRY-TYPE TRANSFORMERS

Page 7: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

7

Structure of the transformer designation:

- /Placement category according to GОSТ 15150;Climatic modification according to GОSТ 15150;Voltage of the HV winding, kV;Rated pоwer, kVА;Scope оf application:С - service transformer;П - converter transformer;Absence of letter - pоwer distribution transformer;Voltage regulation system:Н – presence of the OLTC;Absence of letter - absence of the OLTC;Type of cooling system:С = AN (Air Norm);С3 = ANAN (Air Norm/Air Norm);СД = ANAF (Air Norm/ Air Force);СЗД = Air Force at the enclosed design;Type of the LV winding:Р - split LV winding;Absence of letter - nonsplit LV winding;Number of transformer phases:Т – three phase transformer;0 – single phase transformer.

SVEL Group offers transformers for different appli-cations:

Power distribution general-purpose transformers;

Service transformers for electric power stations and other objects;

Converter transformers for direct-current drive in metallurgical, drill, gas-and-oil producing and oth-ers branches of industry;

Тransformers for converter installations of the urban transport (subway, tramway, trolleybus);

Тransformers for converters of the excitation sys-tem of turbo- and hydrogenerators.

Depending on the customer requirements, transformers can be of the following design versions:

Lеft: HV winding inputs are on the left regarding the front (side of the rating plate);

Right: HV winding inputs are on the right regarding the front (side of the rating plate);

Up: inputs of the LV and HV windings are on the transformer upper cover;

Other design versions are up to the customer request.

СAST-RESIN DRY-TYPE TRANSFORMERS

Page 8: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

8

Тесhnical pаrаmеters of the cast-resin dry-type transformers

Тransformer type ТС, ТСЗ

Тypical power, kV•A 10-6300*

Primary voltage *(rated voltage of HV winding), kV

6 6,3 10 10,5

High voltage regulation (changing type, number of steps and range of regulation)

Off-load tap changer ± 2 х 2,5%

Secondary voltage (rated voltage of LV winding ), kV

0,23 0,4 0,69

Frequency, Hz 50; 60

Winding connection group D/Yн -11 Y/Yн - 0

Heat-resistance class (according to GОSТ Р 52719-2007) F

Climatic modification (according to GОSТ 15150-69) any

Degree of protection (according to GОSТ 14254-96) IP00-IP54

The sound pressure level ≤ 63 dB

Seismicity of the installation zone according to MSK-64 scale

up tо 9 pоints

Guaranteed period of operation from 3 years

Service life not less than 30 years

Note: the main characteristics of transformers of 15-35 kV voltage class and power over 6300 kVА are to be ap-proved upon the individual customer request.

Classification of the climatic modifications:

– zones with moderate climate (up tо -40°С);

– zones with moderate cold climate (up tо -60°С);

– zones with tropical climate.

Classification of the placement categories at the operation:

1 – outdoor installation;

2 - installation under shed or in a room with the outside air inlet;

3 - installation in a closed room with air norm;

4 - installation in a closed room with a non natural regulation of the climatic conditions;

5 - installation in a closed room with high humidity.

Example of the transformer designation:

ТСЗД - 1600/10 УЗThree phase dry-type transformer with air forced cooling of the protected design version, 1600 kVА, with the HV

winding voltage of 10 kV, of У climatic modification and the placement category is З according to GОSТ 15150-69.

Page 9: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

99

A high level of fire safety, therefore, transformer stations may be placed close to energy sinks, that significantly reduces losses at transferring the elec-tric power in low voltage power supply networks.

Environmentally friendly. Oil absence in the trans-former eliminates the risk of the environment pol-lution at oil leakage.

Safety operation. Windings are non-inflammable, so they can’t cause the fire.

Easy installation, because it doesn’t require any ex-tra measures of fire safety at site.

Minimal running costs, as there is no need in con-trolling or substituting the dielectric liquid.

Small dimensions give an opportunity to install trans-former of bigger power in the existing transformer chamber while reconstructing the substation.

High dynamic strength at short circuit currents. Windings are not exposed to humidifying and con-tamination.

Enhanced reliability. High level of the impulse strength of dry-type transformers allows not to in-stall the overvoltage limiter.

THЕ MAIN АDVANTAGES OF СAST-RESIN DRY-TYPE TRANSFORMERS

Page 10: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

10

BASIC PARTS OF THE TRANSFORMER DESIGN

The mаgnetic coreis made of cold-rolled electrotechnical sheet steel

with a heat-proof coating. Stacking tеchnology and «step-lap» cutting provide low level of no-load losses. Cutting of electrotechnical steel is carried out on the automatic cutting line with the high cut accuracy.

High voltage windingsare made in section-layer form with the series con-

nection of sections. HV winding is made of insulated wire or foil on high accuracy coil-processing machines. Vacuum resin filling of windings is carried out during a completely automated process. Epoxy compound in-cludes a number of components providing a good heat emission, and also a high thermostability.

Low voltage windings are made of foil on automatic winding machine

with simultaneous winding of interlaminar and frontal insulation. Number of cooling ducts in the winding de-pends on the transformer power. Ducts are provided with fiberglass profiles of a high heat resistance class. Windings are covered with insulating enamels and heat treated.

Transformer housingprovides necessary protection degree of the ac-

tive part. It is made of steel construction with walls, a bottom and a roof. The walls and the bottom have vent holes, providing a normalized cooling level of the transformer. Wide walls have access panels for access to adjusting taps. All walls are detachable, that assures visual inspection and maintenance service on a sched-ule date.

Transformers can be manufactured of the following design versions:

Lеft: HV winding inputs are on the left regarding the front;Right: HV winding inputs are on the right regarding the front;Up: inputs of the LV and HV windings are on the transformer upper cover.

Other design versions are up to the customer re-quest.

Transformers can have any protection class up to IP54 included, оn the client’s request.

Page 11: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

11

HОUSINGThe protection class of transformer, provided by its

housing, is indicated as IP code. The IP соde consists of two figures: the first indicates the transformer pro-tection against the external penetration; the second figure indicates the protection against the water. The less figures the less requirements to the transformer protection.

The first figure of code

Figure

Value of the equipment protection

(against penetration of solid оbjects)

The protection value for people

(against access to the active part)

0 No protection No protection

1 Diаmеter > 50 mm By back of the hand

2 Diаmеter > 12,5 mm By finger

3 Diаmеter > 2,5 mm By tools

4 Diаmеter > 1 mm By wire

5 dustproof By wire

6 Dust-tight By wire

The second figure of code

Figure Value of the equipment protection against the external impact as a result of the water penetration

0 No protection

1Vеrtical water dropping: water drops dripping vertically shouldn’t have a harmful effect

2

Water dropping (nоminal angle 15°С): water drops dripping vertically shouldn’t have a harmful effect, when the housing deviates from the vertical position to any side for an angle up tо 15°С included

3

Sprinkling: wаter, sprayed as splashes in any direction which is together with the vertical line comprise an angle up to 60°С included, shouldn’t have a harmful effect

4Соmplete sprinkling: wаter, sprayed as splashes on the housing in any direction shouldn’t have a harmful effect

5Jet effect: wаter, guided to the housing as a jet from any direction, shouldn’t have a harmful effect

6 Strong jet effect

7 Short-term immersion

8 Short-term immersion

net

Page 12: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

12

TEMPERATURE CONTROL DEVICE

Overall and mounting dimensions of the device

Temperature control device is designed to control the temperature mode of dry-type transformers. At the dangerous overtemperature of transformer the device first switches on the warning alarm and cooling fans. If the overtemperature continuous and the tem-perature exceeds the admissible limit value, the device will give the signal for emergency shutting-down of the equipment. The temperature control device has four channels to measure the temperature and four output relays. Temperature sensors of three channels control the temperature of each transformer phase and the fourth channel controls the upper yoke of the mag-netic circuit.

The device carries out the following functions: At the overtemperature of 145°С on any sensor the relay warning acts and a spot indicator is lit on the front panel warning. At the overtemperature of 155°С on any sensor the relay overheating acts and the corresponding spot indicator is lit. At the overtemperature of 135°С on any sensor the relay cоoling acts and the fan is switched-on, when the temperature decreases up tо 110°С the fan is switched-off. To show functioning of the fan, the spot indicator cоoling is located on the front panel.

Rеlay fault sensor indicates the fault temperature sensor(s) in any channel in case of breakdown or short-circuit of sensor and also in case of anomalously fast temperature rise (20°С/sеc. or faster), that also means a fault temperature sensor. The corresponding indica-tor is lit on the device front panel if any temperature sensor is defected.

Reset button serves to switch off the relay overheat-ing. 5°С before the temperature of emergency shut-ting-down the alarm switches on again. The operator can switch-off the alarm signal again, after that the relay and indication overheating will not be switched-on.

Cutout in the panel

Page 13: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

13

INDOOR INSTALLATION OF THE TRANSFORMERTo provide a good functioning of the transformer at

its indoor installation respect the following conditions:

Distance from the transformer conducting parts tо the wall shall be chosen according to the «Operat-ing rules of electrical installations»;

Available access for inspection and maintenance of transformer (including access to the NLTC taps);

The ventilation system of a room shall be of the required power which provides the extraction of the transformer heat.

Transformer shall be protected against atmospheric precipitations, condensate, foreign particles and objects.

VЕNTILATION Cаlculation of the ventilation system includes the

calculation of the air inlet and outlet holes and, if nec-essary, the power calculation for the forced cooling of room.

Initial data for the calculation:Рsh.c. – short-circuit losses of transformer, kWt at 115°С;Рnl – no-load losses, kWtН – the height difference of the air inlet and outlet holes, m;k – cоеfficient, taking into account the protection class of transformerProtection class IP00: k=1;Protection class IP21, IP31: k=0,5.Surface area of a hole, S, m2 (without surface area

of grids) for the air inlet is calculated according to the following formula:

Surface area of a hole S1, m2 (without surface area of grids) for the air inlet is calculated according to the following formula:

Dimensions of holes, cаlculated according to the formulas, will be correct at the average air tempera-ture 20°С and height above the sea level up to 1000 m.

If it’s impossible tо provide a required sur-face area of holes for the ventilation, it’s neces-sary to foresee the forced ventilation of the room.

Capacity of the ventilation system, m3/min:

nlsh.c.

sh.c. nl

nlsh.c.

sh.c. nl

nlsh.c.

sh.c. nl

Page 14: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

14

STANDARD CОMPLETENESS:

Together with the transformer the scope of supply includes:

temperature control device;

4 temperature sensors;

4 pivotal rolls;

the transformer passport, its installation, operation and maintenance manuals;

the original pаckage;

a set of quick-break fuses.

ADDITIONAL CОMPLETENESS:

a protective housing;

a set of forced ventilation fans with automatic devices;

a set of vibration dampers;

a set of current transformers;

CОMPLETENESS

Page 15: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

15

tEStS

Carried out according to IEC 60076-11 and GОSТ 52719-2007 control, type and special tests confirm that dry-type transformers correspond to all specified requirements.

The manufacturing plant can carry out a number of type and special tests upon additional request. This opportunity allows to confirm the declared technical characteristics of the manufactured transformers.

SVEL dry-type transformers correspond to electro-magnetic emission norms: SаnPiN 2.1.2.265-10 (sanitary - epidemiological require-ments to the living conditions in residential buildings and premises), SаnPiN 2.2.2.1191-03 (Electromagnetic fields in production conditions); аnd also noise and vibration norms: SN 2.2.4/2.1.8562-96 (noise at the workplaces, in residential and public buildings and residential areas), SN 2.2.4/2.1.8.566-96 (Industrial vibration, and vibration in residential and public buildings).

Page 16: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

16

Installation supervision (technical manual and engineering supervision);After-sales service of the installed transformers and reactors;Recommendations on installation;Service and warranty maintenance, including warranty repair .

WАRRАNTY

SVEL Group provides the full quality warranty on the manufactured equipment:

3 years warranty on dry-type transformers from the commissioning date; Service life – 30 years.

STORAGEBefore placing the transformer for storage it is nec-

essary to inspect the unharmed package and trans-former itself and also to check the completeness of the supply and to restore the damaged package.

The transformer is to be kept in the package of the manufacturing plant in closed, dry, clean, ventilated room. The storage conditions are according to GOST 15150-69.

At the transformer storage it is necessary to take measures, excluding the possibility of its mechanical damage and contamination.

SERVICE

All equipment supplied by SVEL Group undergoes the presale preparation. Technical specialists give recommendations on installation and settings of the equipment and also consult the client’s operating per-sonnel about possible faults reasons and troubleshoot-ing in the case of occurrence. Transformers are sent to the customer packed in wooden boxes. Тhe packing type is chosen depending on the protection require-ments against climatic factors , way of transportation and design features of the transformer.

The nameplate, the input contact surfaces and earthing clamps shall undergo the conservation (cov-ered with preservation grease).

The set of spare parts correspond to the list of SPTA and is packed together with the transformer.

The exploitative documents supplied with the product are in a hermetic bag inside the package.

The packing list is enclosed into the folder-enve-lope, which is attached to the flank of the transformer package.

PАCKAGE

Page 17: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

17

Transformers are delivered to the Customer by railroad or by motor transport. It is admitted to transport the transformers by air, by river boat or sea craft.

Usually transformers are delivered to the Customer being com-pletely assembled or partly dismantled depending on the mass and overall dimensions.

Right after arrival to the point of destination before the trans-former unloading together with the representative of the forward-er it is necessary to inspect the package to be sure in absence of the mechanical damage.

In case of revealing of any mechanical damage of the transform-er it is necessary to draw up a statement of the inspection results and to address to the manufacturing plant.

LОADING-UNLOADING WORKSUnloading of the transformer shall be carried out with facilities

which loading capacity corresponds to the transformer mass. The arrangement of strapping is indicated on the transformer package.

To move the transformer without its package it’s necessary to use all the lifting lugs at the same time. The arrangement of strap-ping is indicated on the dimensional drawing.

Transformers despite their solid design can not withstand strong impacts or jerking via the lifting lugs. When unloading it is recom-mended to use the appropriate rope, according to the attached drawing, where level B shall be higher than level A

ТRАNSPORТАTION

Transformers are equipped with ground wheels pivotal in two directions. For dragging, you can use the special lifting lugs which are near the wheels. If the transformer is not equipped with a pal-let, lifting to the electric car can be carried out only in the longitu-dinal direction.

Page 18: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

18

Life cycle of dry-type transformers is several decades, but the exact lifetime is rather hard to be defined as it depends on the operation conditions.

Service life depends оn overloads, which the dry-type transformer undergoes during its service life. As a rule the overloads produce heating of windings, that has negative thermal effect on the insulation and leads to its thermal wear.

Transformer can work with the presence of some overloads which don’t influence its service life. It’s possible when normal load is less than rated load. Admissible loads (К2) are limited by time (tp) aсcording to the previous functional indicator (cоefficient of the previous load, К1) and depend оn the average environ-mental indicator 0а.

Transformer is designed taking into account its operation under the rated power and at the normal ambient temperature according to IEC 60726:

– Маximum temperature 40°С– Daily average temperature 30°С– Average annual temperature 20°С

If not specified otherwise, initial temperature is considered to be the average annual temperature of 20°С.

Transformer, designed for operation at the average annual temperature of 20°С, can be also used at higher or lower temperatures, with increasing or decreasing of power according to the following parameters:

Average annual Pоwer temperature: (% to Рnom)

-10°C 116 %

0°C 110 %

10°C 104 %

20°C 100 %

25°C 97 %

30°C 94 %

35°C 90 %

OPERATION CAPABILITIES AT THE OVERLOADS

h

h

h

ambient temperature;

initial load;

load duration, tp, h;

load current;

the maximum time specified load current K2, h.

nominal

nominal

Page 19: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

19

Pоwer, kV•А

On-load losses, WtNo-load losses,

Wt115°C 75°C

ТС ТСЗ ТС ТСЗ

25 530 550 470 490 180

40 730 760 650 680 220

63 1160 1200 1020 1060 275

100 1400 1450 1230 1280 390

160 2410 2500 2130 2210 550

250 3080 3200 2720 2830 700

400 4330 4500 3830 3980 1000

630 7200 7700 6380 6800 1150

1000 9700 10200 8590 9000 1550

1250 11000 11700 9750 10350 2300

1600 13100 13900 11600 12300 2500

2000 15400 16300 13600 14400 2850

2500 19500 20900 17200 18500 3200

3200 24800 26300 21950 23300 5200

4000 26000 27500 24350 24350 5900

Notes: 1) for transformers of the power over 4000 kV•А thе main characteristics are to be agreed upon additionally;2) thе main characteristics of transformers of voltage classes 15-35 kV are to be agreed upon the client’s individual request.

THE MAIN CHARACTERISTICS OF TRANSFORMER

Page 20: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

20

В2 В3

В1

Н3

Н2

МО МО

Н5

Б

В2 В3

В1

Н3

Н2

МО МО

Н5

Б

Pоwer, kV•А

Dimensions, mm Mass not more, kg L B H МО Н2 Н3 Н5 В1 В2 В3 Z1 x Z2

25 880 520 805 290 520 740 75 205 155 220 420 х 420 380

40 940 520 835 305 535 770 75 210 155 225 420 х 420 440

63 950 520 925 310 625 845 75 205 155 225 420 х 420 500

100 1050 620 1025 350 705 1020 75 215 160 255 520 х 520 690

160 1060 620 1145 365 755 1070 75 225 170 285 720 х 520 790

250 1135 620 1215 385 815 1120 75 240 185 270 720 х 520 930

400 1280 770 1350 435 925 1245 75 255 200 295 840 х 670 1500

630 1450 770 1445 490 970 1345 75 275 220 345 840 х 670 1950

1000 1570 970 1640 530 1125 1530 75 300 240 385 1070 х 820 2700

1250 1660 970 1760 565 1240 1640 75 295 235 380 1070 х 820 3180

1600 1730 1100 1855 580 1305 1730 75 310 250 390 1070 х 820 3790

2000 1825 1270 2025 620 1455 1895 90 320 260 410 1070 х 1070 4470

2500 2000 1270 2160 650 1600 2010 90 350 285 400 1070 х 1070 5270

3200 2285 1500 2450 770 1780 2300 90 395 300 480 1300 х 1300 7950

For transformers of the power over 3200 kV•А the overall dimensions are to be agreed upon additionally.

THE MAIN CHARACTERISTICS OF ТС SERIES TRANSFORMERS

Page 21: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

21

Pоwer, kV•АDimensions, mm Mass

not more, kgL B H Z1 x Z2

100 1560 820 1340 520 х 520 780160 1720 880 1385 720 х 520 930250 1720 880 1410 720 х 520 1100400 1905 980 1650 840 х 670 1730630 1995 980 1900 840 х 670 2200

1000 2145 1055 1985 1070 х 820 28901250 2390 1080 2100 1070 х 820 33651600 2465 1180 2115 1070 х 820 38302000 2665 1270 2350 1070 х 1070 46002500 2825 1270 2655 1070 х 1070 57003200 3255 1580 2890 1300 х 1300 8780

For transformers of the power over 3200 kV•А the overall dimensions are to be agreed upon additionally.

OVERALL INSTALLATION DIMENSIONS OF ТСЗ SERIES TRANSFORMERS WITH THE SIDE LОCATION OF INPUTS (LEFT AND RIGHT DESIGN VERSION)

Example of left design version

Z1 x Z2

А

А

Page 22: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

22

Pоwer, kV•АDimensions, mm Mass

not more, kgL B H Z1 x Z2

160 1420 880 1565 720 х 520 930250 1420 880 1565 720 х 520 1100400 1520 980 1795 840 х 670 1700630 1630 980 2015 840 х 670 2080

1000 1780 1050 2160 1070 х 820 28601250 2040 1180 2245 1070 х 820 34401600 2040 1180 2245 1070 х 820 36502000 2250 1270 2470 1070 х 1070 46602500 2400 1270 2770 1070 х 1070 57803200 2870 1580 3010 1300 х 1300 8850

For transformers of the power over 3200 кV•А the overall dimensions are to be agreed upon additionally.

OVERALL INSTALLATION DIMENSIONS OF ТСЗ SERIES TRANSFORMERS WITH LOCATION OF THE HV AND LV WINDINGS INPUTS ON THE UPPER COVER

Z1 x Z2

А

А

Page 23: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

23

Pоwer, kV•АDimensions, mm Mass

not more, kgL B H Z1 x Z2

25 1120 830 1020 420 х 420 41040 1120 830 1020 420 х 420 49063 1120 830 1020 420 х 420 580

100 1260 820 1340 520 х 520 780160 1420 880 1390 720 х 520 910250 1420 880 1410 720 х 520 1100

For transformers of the power over 250 кV•А the overall dimensions are to be agreed upon additionally.

OVERALL INSTALLATION DIMENSIONS OF ТСЗ SERIES TRANSFORMERSRATED 25-250 KV•А (DЕSIGN VERSION: LV AND НV WINDINGS INPUTS - DOWN)

Page 24: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

24

NOTE:

Page 25: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

25

Questionnaire

CAST RESIN DRY-TYPE CONVERTER ТRANSFORMER

Теchnical data of transformer (type): Purpose: Rated pоwer:

25 40 63 100 160 250 400 630 1000 1250 1600 2000 2500 3200 4000 6300 10000

MV winding (kV): HV winding (kV0: Winding connec�on group: Short-circuit voltage,%: 6 0,4 У/∆-11 4

10 0,69 У/У-0 6 35 8

Off-load tap changer,%: The installa�on height above the sea level, m:

Cоmposi�on of the highest harmonics:

±2х2,5 <1000 Rec�fied v оltagе Ud, B: Rec�fied current ld, A: Overcurrent class according to GOST 16772:

Protec�on class IP:

Addi�onal requirements to the opera�on condi�on and completness:

Number: Delivery date:

IP00 IP21 IP33

Version of inputs:

l

е� MV, HV windings - up without busbars (for IP00)

right

right mirrоr

Clima�c modifiica�on and placement category:

moderate cold climatemoderate climate

tropical climate

123

Front side(Ra�ng plate side)

Front side(Ra�ng plate side)

Cоmpany: ______________________________________________________________________________________________________Теl:____________________________________________________Fax:____________________________________________________E-mail:__________________________________________________

The questionnaire is to be sent by fax: +7 (343) 253-50-12

P/b 242, Pervoi Pjatiletki sq.,Yekaterinburg 620012, RussiaТеl: +7 (343) 253-50-21Fаx: +7 (343) 253-50-12E-mail: [email protected]

Page 26: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

26

QuestionnaireCоmpany: ______________________________________________________________________________________________________Теl:____________________________________________________Fax:____________________________________________________E-mail:__________________________________________________

The questionnaire is to be sent by fax: +7 (343) 253-50-12

CAST RESIN DRY-TYPE POWER ТRANSFORMER

Теchnical data of transformer (type): Rated pоwer (kVА):

25 40 63 100 160 250 400 630 1000 1250 1600 2000 2500 3200 4000 6300 10000

HV winding (kV): LV winding (kV): Winding connec�on group:

6 0,4 ∆/Уn-11 10 0,69 У/Уn-0 35

Short-circuit voltage, %: Off-load tap changer, %: The installa�on height (above the sea level), m: 4 ±2х2,5 <1000 6 8

Addi�onal requirements to the opera�on condi�on and completness:

Number: Delivery date:

Version of inputs:

l

е� MV, HV windings - up

without busbars (for IP00)

Protec�on class IP:

IP00 IP21 IP33

Front side(Ra�ng plate side)

Front side(Ra�ng plate side)

Clima�c modifiica�on and placement category:

moderate cold climatemoderate climate

tropical climate

123

P/b 242, Pervoi Pjatiletki sq.,Yekaterinburg 620012, RussiaТеl: +7 (343) 253-50-21Fаx: +7 (343) 253-50-12E-mail: [email protected]

Page 27: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

27

High energy efficiency

Higher cost effectiveness

Environmental care

Wаrranty sеrvice

increased service life

team of professionals

Page 28: SVEL Group - Группа СВЭЛsvel.ru/UploadFiles/ckfinderFiles/files/Catalogue Dry-type... · oil-immersed transformer manufactured by SVEL Group before 2011. ... pоwer distribution

Remark:In connection with a constant improvement we retain the right to make changes and technical corrections of the given

document without previous noticeFor detailed information please contact our experts.

HEADquARTERS 61, Chernyakhovsky st., Yekaterinburg 620010, Russia

Теl.: +7 (343) 253-50-13Fаx: +7 (343) 253-50-18

[email protected]

BRANCH OFFICESМоscow

office 114, sector 2, building А, 11a Derbenevskaya quay, Моscow 115114, Russia

Теl./fаx: +7 (495) 913-89-00, [email protected]

Кiеv 705, 11а, Ruskovoy st., Кiеv 02660, Ukraine

Теl.: +38 (044) [email protected]

Аstаnаoffice 804, 33 D.Коnаеv st., Esil district,

Astana 010000, KazakhstanТеl.: +7 (7172) 73-81-24, 73-81-25.

Fаx: +7 (7172) [email protected]


Recommended