Page 1/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Synco living Train the Trainer Introduction Safety & Security Spring 2008
Transcript
Page 1: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 1/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Synco living

Train the Trainer

Introduction Safety & Security

Spring 2008

Page 2: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 2/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & SecurityIntroduction

Overview security

Supervisory functionsSmoke supervisionWindow supervisionDoor supervisionFault inputs

AlarmsFault outputs

SignalingBuzzerStatus output

Page 3: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 3/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Smoke Supervision

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

The central apartment unit can monitor up to 12 smoke detectors [KNX RF or

KNX TP1(S-mode)] (1 smoke detector per room).

If smoke is detected, the smoke detector sends alarm telegrams to the central

apartment unit.

In the central apartment unit, the smoke alarm is forwarded to the fault

manager and the signaling section.

Page 4: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 4/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Smoke Supervision

Fault manager

Fault output 1

Fault output 2

As soon as the central apartment unit‘s fault manager receives a smoke

alarm, the following actions will be executed:

Display of the smoke alarm on info page “Device state" including name

of smoke

The quiescent picture shows symbol

The smoke alarm is saved in the fault history (10 entries)

Delivery of a fault status message via KNX TP1, provided there is no other, more severe fault pending in the system

If optional fault output 1 or 2 is configured, the relevant relay contact will close

Smoke alarm

Page 5: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 5/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Smoke Supervision

Signaling

Status output

Buzzer

As soon as the central apartment unit‘s signaling section receives a smoke alarm, the following actions will be executed:

Activation of the central apartment unit‘s built-in buzzer, provided the “Smoke“ event for the buzzer is activated

If the optional status output is configured, the respective relay contact will close, provided the “Smoke“ event for the status output is activated

Note: Both buzzer and status relay will again be deactivated when the set signal duration has elapsed, or by pressing a button on the central apartment unit, independent of the state of smoke supervision.

Smoke alarm

Page 6: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 6/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

Display window state

Window / door state

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

Quiescent picture

Info page windows/doors

Relay output

Page 7: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 7/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

Display window state

The central apartment unit can monitor up to 6 window contacts per room (KNX RF) or 1 KNX TP1 (S-mode).

If at least one of the windows is left open, symbol appears in the quiescent picture on the central apartment unit. Using the info pages of the individual rooms, or info page “Windows / doors“, it is possible to find out in which room a window was left open.

Note:If windows and doors were left open, the quiescent picture shows both symbols alternating.

Window open

Page 8: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 8/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

Window / door state

Info page “Windows / doors“ shows all windows and doors presently open.

If more than 4 windows and doors are open at the same time, the information will be given on several info pages.

If all windows and doors are closed, the display will show it.

Window open

Page 9: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 9/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

As a physical door / window state output, select one of the following:

Relay output Q of the central apartment unit

Relay output Q of a heating circuit controller RRV91x or a multicontroller RRV934

Output via S-mode KNX TP1 (configuration via ETS)

OutputWindow / door state

Window open

Page 10: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 10/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

The rooms in which the window contacts shall be monitored can be selected (enabling supervision). This means that certain windows can be left open without triggering an alarm.

If, while supervision is active, an open window contact is detected in a monitored room, the central apartment unit instantly forwards the window alarm to the fault manager and the signaling section.

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

Window openAbsence

Page 11: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 11/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

Fault manager

Fault output 1

Fault output 2

As soon as the central apartment unit‘s fault manager receives a window

alarm, the following actions will be executed:

Display of window alarm on info page “Device state“, plus the room‘s

name

The quiescent picture shows symbol .

The window alarm is saved in the fault history (10 entries)

Delivery of a fault status message via KNX TP1, provided there is no other, more severe fault pending in the system

If optional fault output 1 or 2 is configured, the relevant relay contact will close

Message “Window open“ disappears from the display only after the next change of supervision

Window openAbsence

Page 12: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 12/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Window Supervision

Signaling

Status output

Buzzer

As soon as the central apartment unit‘s signaling section receives a window alarm, the following actions will be executed:

Activation of the central apartment unit‘s built-in buzzer, provided the “Window / door supervision" event for the buzzer is activated

If the optional status output is configured, the respective relay contact will close, provided the “Window / door supervision“ event for the status output is activated

Note: Both buzzer and status relay will again be deactivated when the set signal duration has elapsed, or by pressing a button on the central apartment unit, independent of the state of window / door supervision.

Window openAbsence

Page 13: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 13/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

Display door state

Window / door state

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

Quiescent picture

Info page Windows/doors

Relay output

Page 14: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 14/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

Display door state

The central apartment unit can monitor up to 2 door contacts per apartment / house (KNX RF or KNX TP1 [S-mode]).

If at least one door is left open, symbol appears in the quiescent picture on the central apartment unit.

Note:If windows and doors were left open, the quiescent picture shows both symbols alternating.

Door open

Page 15: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 15/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

Window / door state

Info page “Windows / doors“ shows all windows and doors presently open.

If more than 4 windows and doors are open at the same time, the information will be given on several info pages.

If all windows and doors are closed, the display will show it.

Door open Output

Page 16: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 16/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

As a physical door / window state output, select one of the following:

Relay output Q of the central apartment unit

Relay output Q of a heating circuit controller RRV91x or a multicontroller RRV934

Output vis S-Mode KNX TP1 (configuration via ETS)

OutputWindow / door state

Door open

Page 17: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 17/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

The doors that shall be monitored can be selected (enabling supervision). This means that certain doors can be opened while supervision is active, without triggering an alarm.

If an open door contact is detected in a monitored house / apartment, the central apartment unit forwards the door alarm to the fault manager and signaling section as soon as the adjustable signal delay time has elapsed.

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

Door open Absence

Page 18: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 18/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

Fault manager

Fault output 1

Fault output 2

As soon as the central apartment unit‘s fault manager receives a door alarm,

the following actions will be executed:

Display of door alarm on info page “Device state“

The quiescent picture shows symbol

The door alarm is saved in the fault history (10 entries)

Delivery of a fault status message via KNX TP1, provided there is no other, more severe fault pending in the system

If optional fault output 1 or 2 is configured, the respective relay contact will close

Message “Door open“ disappears from the display only after the next change of supervision

Door openAbsence

Page 19: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 19/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Door Supervision

Signaling

Status output

Buzzer

As soon as the central apartment unit‘s signaling section receives a door alarm, the following actions will be executed:

Activation of the central apartment unit‘s built-in buzzer, provided the “Window / door supervision“ event for the buzzer is activated

If the optional status output is configured, the respective relay contact will close, provided the “Window / door supervision“ event for the status output is activated

Note: Both buzzer and status relay will again be deactivated when the set signal duration has elapsed, or by pressing a button on the central apartment unit, independent of the state of window / door supervision.

Door openAbsence

Page 20: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 20/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Fault Inputs

Fault manager

Signaling

Fault output 1

Fault output 2

Status output

Buzzer

On the central apartment unit, up to 8 universal digital fault inputs available. Typical input signals at these inputs are:

Level switch (e.g. for oil level)

Alarm output of an intrusion alarm system

Thermal switch

If a fault is detected at one of the fault inputs, it will be forwarded to the central apartment unit‘s fault manager and signaling section.

12345678

Page 21: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 21/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Fault Inputs

Per fault input, the following options are available as physical fault inputs:

Universal input Bat the central apartment unit

Universal input B of heating circuit controller RRV91x or a multicontroller RRV934

Door / window contact AP260

S-mode input via KNX TP1 (configuration with ETS)

Page 22: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 22/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Fault Inputs

As soon as the central apartment unit‘s fault manager receives a fault status message from one of the fault inputs, the following actions will be executed:

Display of an alarm text on the info page

The quiescent picture shows symbol

The fault is saved in the fault history (10 entries)

Delivery of a fault status message via KNX TP1, provided there is no other, more severe fault pending in the system

If optional fault output 1 or 2 is configured, the relevant relay contact will close

Fault manager

Fault output 1

Fault output 2Fault status message

Page 23: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 23/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Fault Inputs

As soon as the central apartment unit‘s signaling section receives a fault status message from one of the fault inputs, the following actions will be executed:

Activation of the central apartment unit‘s built-in buzzer, provided the “Fault input x“ event for the buzzer is activated

If the optional status output is configured, the respective relay contact will close, provided the “Fault input“ event for the status output is activated

Note: Both buzzer and status relay will again be deactivated when the set signal duration has elapsed, or by pressing a button on the central apartment unit, independent of the state of the fault input.

Signaling

Status output

BuzzerFault status message

Page 24: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 24/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Fault Outputs

Fault manager

Fault output 1

Fault output 2

The following optional outputs are available as physical fault outputs:

Relay output Qat the central apartment unit

Relay output Q of aheating circuit controller RRV91x or a multicontroller RRV934

Page 25: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 25/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Buzzer

The central apartment unit‘s built-in buzzer responds in the following situations:

After successful binding=> short signal tone

After each successful binding test=> 3 short signal tones

After occurrence of one of the following events (if defined):SmokeWindow / door supervisionFault input 1…8

=> continuous tone with adjustable signal duration

Page 26: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 26/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Status Output

At the status input, a horn or flash light can be connected, if the built-in buzzer is not sufficient.

The following outputs are available as physical status outputs:

Relay output Q at thecentral apartment unit

Relay output Q of a heating circuit controller RRV91x ora multicontroller RRV934

S-mode output via KNX TP1 (configuration with ETS)

Page 27: Synco living - Siemens8... · 2020. 5. 31. · Page 11/27 Train the Trainer - Spring 2008 Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output Introduction

Page 27/27 Train the Trainer - Spring 2008

Introduction Smoke Windows Doors Fault Inputs Fault Outputs Buzzer Status Output

Introduction Safety & Security Status Output

After occurrence of one of the following events, the status output will be closed for the adjustable signal duration:

Smoke

Window / door supervision

Fault input 1 … 8


Recommended