+ All Categories
Home > Documents > System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers,...

System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers,...

Date post: 12-May-2020
Category:
Upload: others
View: 10 times
Download: 1 times
Share this document with a friend
746
User manual System messages CSC-W32 V2.0/52
Transcript
Page 1: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

User manual

System messages CSC-W32 V2.0/52

Page 2: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Questions and suggestions

June 2004

Do you have ...

... any questions or suggestions regarding ... any technical questions or problems? this manual? Please note the order number or the date Please refer to the Wincor Nixdorf of issue of this manual and refer it to: Customer Care Center: address: E-mail: [email protected] Wincor Nixdorf International GmbH Handbuchredaktion BD P5 33094 Paderborn Germany Fax: +49 (0) 5251 693 - 4368

Page 3: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

System messages

CSC-W32 V2.0/52

Edition June 2004

Page 4: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Copyright © Information and trademarks

June 2004

© Wincor Nixdorf International GmbH 2004

All rights, including rights of translation and rights of reproduction by reprinting, copying or similar methods, even of parts, are reserved. Any violations give rise to a claim for damages.

All rights, including rights created by patent grants or registration of a utility model or design, are reserved. Delivery subject to availability; right of technical modifications reserved.

All names of hardware and software products mentioned in this manual are trade names and/or trademarks of their respective manufacturers.

Page 5: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004

Contents

Preface ................................................................................................................................1 Target group ........................................................................................................................1 Summary of contents ...........................................................................................................1 Notational conventions.........................................................................................................2

Message handling..............................................................................................................3 Status/error classes .............................................................................................................4

Allocation of error codes .................................................................................................7 Error entry ............................................................................................................................8

Global error codes .............................................................................................................9 CSC error codes .............................................................................................................9 INI error codes ..............................................................................................................16

Return code handler (RCH).............................................................................................21

Error statistics (EST) .......................................................................................................25

Transaction statistics (TRA) ...........................................................................................29

COMM mutiplexer ............................................................................................................31

IEEE 1394..........................................................................................................................43

Universal serial bus (USB)..............................................................................................63

DFU / DFUX Loader (DFU) ...............................................................................................83

Power Suspend Mode Manager (PSM) ..........................................................................87

Card reader unit (IDU)......................................................................................................89

MM security system (MSS)............................................................................................107

Chip card module (CCM) ...............................................................................................113

Page 6: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004

Special electronics (SEL / SEV4)................................................................................. 115

Softkey/PINpad (PIN) .................................................................................................... 127

Operator Panel (OPL) ................................................................................................... 133

CIT Control Panel (CIT)................................................................................................. 141

Encryption/Decryption Software (EDS) ...................................................................... 143

Encryption/Decryption module (EDM) ........................................................................ 147

Secure Cash-Out (SCO)................................................................................................ 163

RSA module................................................................................................................... 167

Remote Key Loading .................................................................................................... 169

CBKM module................................................................................................................ 173

Swiss Encryption Protocol (SEP)................................................................................ 175

Security Module SIBS................................................................................................... 181

Online Personalization Terminals (OPT) .................................................................... 185

EPP Firmware Loader (LDE) ........................................................................................ 193

ZKA 3.0 (ZKA) ................................................................................................................ 205

Printer (general) ............................................................................................................ 221

ND05 printer / PMxx / Document reader ..................................................................... 227

Scanner module (SCAN) .............................................................................................. 237

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer.............................................. 245

ND79 printer................................................................................................................... 253

ND75, ND75S, ND94 printer.......................................................................................... 257

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer.................................................. 263

ND97 firmware loader (LDR3) ...................................................................................... 273

Page 7: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004

ND99 printer ...................................................................................................................275

TH21 printer....................................................................................................................281

HPEM printer ..................................................................................................................287

PRTX Printer messages ................................................................................................291

Print System Framework...............................................................................................293

LDND9G - Loader for printer ND9G..............................................................................299

LMND9G Printer Monitor ...............................................................................................301

LMTH21 Printer Monitor ................................................................................................305

LDTH5X Firmware Loader .............................................................................................309

LMTH5X Printer Monitor................................................................................................313

LMTP07 Printer Monitor ................................................................................................319

RJ03 Printers..................................................................................................................323

SB500 scanner (S500) ...................................................................................................329

CM3000 scanner (CM3K)...............................................................................................339

TOSCA scanner (TSC) ...................................................................................................353

Scanner software RecoStar (RECO) ............................................................................361

Cash-Out Module (CDM)................................................................................................413 Position of photosensors ............................................................................................481

Cash-Out Module (CNG)................................................................................................487

CNG: extended error codes ..........................................................................................495

Firmware loader (LDR) ..................................................................................................581

Paragraph 36 (P36) ........................................................................................................583

Coin-Out Module (COUT) ..............................................................................................587

Page 8: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004

Coin-In Module (CIN)..................................................................................................... 593

Bundle Cash Deposit Module (BCD)........................................................................... 597

Deposit Module (DPS) .................................................................................................. 605

Cash-Cheque Dispenser Module (CCDM) .................................................................. 617

CCDM: extended error codes ...................................................................................... 639

Money Door Module (MDM).......................................................................................... 661

Panel Protection Door (PPD) ....................................................................................... 667

Numeric list of all messages........................................................................................ 675

Page 9: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 1

Preface The CSC-W32 software products allow the operation of self-service systems with the standard operating system Windows NT®, Windows 2000® and Windows XP®.

The following WN-specific Windows 32 bit products can be used with this standard operating system to control the self-service peripherals:

CSC-W32/BOF Basic self-service functions CSC-W32/CDM Cash dispenser module CSC-W32/SFP Security facility package CSC-W32/SDK Software development kit

Target group This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages which can be output from the CSC-W32 products. This enables a fast elimination of faults which guarantees high availability of the self-service system.

Summary of contents The description of the message handling and the explanation of the general system messages are followed by further descriptions in the order of the devices. The messages are ordered numerically at the end of the manual. This helps find the description corresponding to the message within this manual.

Page 10: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Notational conventions Preface

2 June 2004

Notational conventions The format of the message description is as follows:

– Error code and define Listed sequentially in numerical order.

– Cause Detailed description of the error. The causes are ordered according to the probable error frequency.

– Application If the message can be interpreted and acted on by the application programmer, then the required actions are given here. This section serves as an aid for the application programmer and should help him react correctly to errors in the application during run-time. For this reason, these notes should only be consulted when creating user pro-grams.

– Measure Errors and messages to which the system operator and system administrator can react.

Example:

XXXX Define Cause: – Description of the cause which occurs most frequently. – Description of the cause with the next highest frequency of occurrence. – etc. Application: Instructions for the application programmer are given here. Measure: The actions to be taken by the system operator or the system administrator are described here.

Page 11: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 3

Message handling Parameters are passed via the standard device handler interface in the CSCDHLPARA structure. The messages are divided into status or error classes (StClass), error specifi-cation (StCode) and warning specification (StWarn).

StClass

The following messages can be found in the "StClass" field:

STCLASS_OK No error or warning has been received from the device handler.

STCLASS_ERROR_COMM The COMM DLL reports an error with the V.24, ECP or USB channel. Further information can be found in the "StCode" field.

STCLASS_ERROR_XYZ The XYZ device handler reports an error. Further infor-mation can be found in the "StCode" field.

StCode, StWarn

The messages in the "StCode" and "StWarn" fields are described in the sections for the device handlers.

Page 12: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Status/error classes Message handling

4 June 2004

Status/error classes The following table contains the current valid values for the Status Class:

Definition Value Description

STCLASS_OK 00 01–02

No error reserved

STCLASS_ERROR_USB 03 Universal Serial Bus

STCLASS_ERROR_1394 04 IEEE 1394 Multiplexer

STCLASS_ERROR_COMM 05 COMM Multiplexer/Protocol Handler

STCLASS_ERROR_TKM 06 Ticket Door Module

STCLASS_ERROR_CDM 07 Cash Dispenser Module

STCLASS_ERROR_IDU 08 ID Card Unit

STCLASS_ERROR_PIN 09 Softkey/PINpad

STCLASS_ERROR_SEL 0A Special electronic

STCLASS_ERROR_RCH 0B Return Code Handler

STCLASS_ERROR_INI 0C Error in INI Module. This error is reported only when the INI module is accessed directly.

STCLASS_ERROR_MDM 0E Money Door Module

STCLASS_ERROR_EDM 0F Encryption/Decryption Module (HW)

STCLASS_ERROR_EDS 11 Encryption/Decryption Module (SW)

STCLASS_ERROR_TLS 12 Trace and Error Logging

STCLASS_ERROR_MSS 13 MM and CIM-86 Security System

STCLASS_ERROR_OPL 14 Operator Panel

STCLASS_ERROR_PPD 15 Panel Protection Door

STCLASS_ERROR_DPS 17 Deposit Module

STCLASS_ERROR_CNG 18 Cash Dispenser Module NG

STCLASS_ERROR_EST 19 Error statistic

Page 13: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Message handling Status/error classes

June 2004 5

Definition Value Description

STCLASS_ERROR_CCDM 1A Cheque Cash Deposit Module

STCLASS_ERROR_SCAN 1B Scanner Module

STCLASS_ERROR_TRA 1C Transaction statistic

STCLASS_ERROR_CNG_EXT 1D CSCCNG extended error codes

STCLASS_ERROR_LDR 1E Firmware loader CNG

STCLASS_ERROR_LDR3 1F Firmware loader ND97

STCLASS_ERROR_CIT 20 Central ProPrint Module CSCWCIT

STCLASS_ERROR_COUT 21 Coin-Out Module

STCLASS_ERROR_CIN 22 Coin-In Module

STCLASS_ERROR_RECO 23 Scanner Software RecoStar (S500)

STCLASS_ERROR_SCO 24 Secure Cash-Out

STCLASS_ERROR_BCD 25 Bundle Cash Deposit

STCLASS_ERROR_CCM 26 Chip Card Module

STCLASS_ERROR_P36 27 Paragraph 36

STCLASS_ERROR_SEP 28 Swiss Encryption Protocol

STCLASS_ERROR_ZKA 29 ZKA 3.0 (only for Germany)

STCLASS_ERROR_PSM 2A Power Suspend Mode Manager

STCLASS_ERROR_PPXD 2B ProPXD: Platform Extensions for Diagnostic

STCLASS_ERROR_OPT 2C Online Personalization Terminal

STCLASS_ERROR_LDE 2D Firmware Loader EPP

STCLASS_ERROR_RSA 2E RSA Encryption Module

STCLASS_ERROR_CBKM 2F Cartes Bancaires Key Management

STCLASS_ERROR_SIBS 30 Security Module SIBS

STCLASS_ERROR_DFU 31 Device Firmware Upgrade

STCLASS_ERROR_PRT 32 Printer

STCLASS_ERROR_ND71 33 Printer ND71 / ND74 / ND98 / ND9A / ND9C / ND9E / TH30

Page 14: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Status/error classes Message handling

6 June 2004

Definition Value Description

STCLASS_ERROR_ND94 34 Printer ND75 / ND75S / ND94

STCLASS_ERROR_ND79 35 Printer ND79

STCLASS_ERROR_ND05 37 Printer ND05 / PMxx / document reader module

STCLASS_ERROR_ND99 38 Printer ND99

STCLASS_ERROR_ND97 39 Printer ND97 / TH97 / TP01 / NP01 / TP05 / NP05 / TP09

STCASS_ERROR_HPEM 3A Printer HPEM

STCLASS_ERROR_S500 3B Scanner SB500

STCLASS_ERROR_TSC 3C Scanner TOSCA

STCLASS_ERROR_CM3K 3D Scanner CM3000

STCLASS_ERROR_TH21 3E Printer TH21

STCLASS_ERROR_PRTX 3F Printer Extensions

STCLASS_ERROR_LMND9G 40 LMND9G Printer

STCLASS_ERROR_LMTH21 41 LMTH21 Printer

STCLASS_ERROR_LMFRAME 42 Print System Framework

STCLASS_ERROR_LDND9G 43 Loader for printer ND9G

STCLASS_ERROR_LMTP07 44 TP07 Printer Monitor

STCLASS_ERROR_R03 45 Printer Family RJ03 (receipt printers)

STCLASS_ERROR_LMTH5X 46 TH5X Printer Monitor

STCLASS_ERROR_LDTH5X 47 Loader for printer TH5X

STCLASS_ERROR_J03 48 Printer Family RJ03 (journal printers)

STCLASS_ERROR_RKL 5F Remote Key Loading

STCLASS_ERROR_EDM_COMM 0F05 PIN: V.24 communication failure between hardware encryption module and PC

STCLASS_ERROR_CDM_COMM 0705 IDCU: nested error of the MM module in the V.24 communication with the CDM device

Page 15: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Message handling Status/error classes

June 2004 7

Definition Value Description

STCLASS_ERROR_CDM_EDS 0711 IDCU: nested encryption error of the MM module during the encrypted communication between PC and CDM

STCLASS_ERROR_MSS_COMM 1305 Error in communication between MSS-DHL and CIM-86 or MM module

STCLASS_ERROR_MSS_EDS 1311 Problems with decryption of data with CIM-86 module

STCLASS_ERROR_CIT_COMM 2005 ProPrint: nested error of the CSCWCIT module in the connection with the attached devices

STCLASS_ERROR_CIT_LDR3 201F ProPrint: nested error of the CSCWCIT module during loading the firmware of the ND97 printer.

STCLASS_ERROR_P36_COMM 2705 P36: communication failure between the PC and the hardware for sampling the signature data.

Allocation of error codes

The error codes are allocated to the following areas:

Error codes Areas

0x0000 0x0000.0001 - 0x1FFF.FFFF 0x2000.1000 - 0x2000.1FFF 0x2000.2000 - 0x2000.2FFF 0x2000.3000 - 0x2000.37FF 0x2000.3800 - 0x2000.3FFF 0x2000.4000 - 0x2000.47FF 0x2000.4800 - 0x2000.4FFF 0x2000.8000 - 0x2000.FFFF 0x2800.0000 - 0x3FFF.FFFF 0x4000.0000 - 0xFFFF.FFFF

No error occurred Windows error codes Global CSC error codes INI DLL error codes Function canceled, global CSC codes Function canceled, DHL-specific codes Function time-out, global CSC codes Function time-out, DHL-specific codes DHL-specific error codes CSC firmware codes Windows errors

Page 16: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Error entry Message handling

8 June 2004

Error entry The error entries of the CSC-W32/OS are entered by means of two tools:

WindowsNT Event Logging The event logging system supplied with Windows NT can be used. The Event Viewer allows you to view the errors of the CSC-W32 under the Application error area.

TLS-W32 Since no event logging system is available under Windows 95, the tool TLS-W32 supplied with the CSC-W32 is available. This tool has been ported from TLS/2 of the CSC-O/OS product to Win32. This tool is also available under Windows NT so that the user is free to decide, by a generation in the CSC.INI, whether the CSC-W32 errors are logged in the Windows NT event logging system or in the TLS-W32 system.

After installing the Return Code Handler, not only the hex codes of StClass, StCode and StWarn are written into the log file, but also the appropriate definitions.

With the utility CSCHELP all information about an error listed in this manual can be read online.

Page 17: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 9

Global error codes All global error messages, which are returned from the device handlers in "StCode", are listed in this section. They are described in the include file CSCDEF.H. an entry in "StClass" allocates the error message to the corresponding device handler.

CSC error codes

20001001 CSC_FUNCTION_NOT_IMPLEMENTED Reason: The function is not implemented. Application: Check application program.

20001003 CSC_INVALID_SPEC Reason: The function specification "CscDhlPara.Spec" given in the parameter block is invalid. Application: Check application program.

20001004 CSC_INVALID_INLEN Reason: The length specified for the input buffer "CscDhlPara.InLen" in the parameter block is invalid. Application: Check application program.

20001005 CSC_INVALID_OUTLEN Reason: The length specified for the output buffer "CscDhlPara.OutLen" in the parameter block is invalid. Application: Check application program.

Page 18: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

10 June 2004

20001006 CSC_INVALID_LOGICAL_ID Reason: The logical ID specified in the Open/GetRelease command is invalid. Application: Check application program. Check the logical ID in Registry. Measure: Consult the application programmer. Modify Registry if necessary.

20001007 CSC_INVALID_PID Reason: The process, which called this function of the device, is not identical with the process which opened the device. Application: Check application program.

20001009 CSC_DEVICE_ALREADY_OPENED Reason: The device, on which an OPEN command was executed, is already opened non-shared. Application: Check application program. Measure: Check whether another application in the system has already opened this device.

2000100D CSC_CSCINI_DLL_NOT_FOUND Reason: The CSCWINI.DLL could not be found in the PATH. Normally <CSCROOT>\DLL. Measure: Check whether CSCWINI.DLL is in the PATH. Normally <CSCROOT>\DLL.

2000100E CSC_CSCINI_DLL_OPEN_FAILED Reason: The CSCWINI.DLL could not be opened. Measure: Report the error log of this entry to Service.

Page 19: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

June 2004 11

2000100F CSC_DHL_NOT_INITIALIZED Reason: The device handler has not yet been initialized. Application: Check application program. Execute CscXyzInit if required.

20001014 CSC_REL_NOT_AVAIL Reason: No release is currently available under the stated specification. Application: Check application program. Retry job if necessary.

20001015 CSC_INVALID_COMMAND Reason: An attempt was made to execute a command which was not permitted or possible for this application or configuration. Application: Check application program

20001017 CSC_TOO_MANY_USERS Reason: This device has already been opened by the max. number of users in SHARED mode. Application: Check application program

20001018 CSC_CSCEDS_DLL_NOT_FOUND Reason: The CSCWEDS.DLL could not be found in the PATH. Normally <CSCROOT>\DLL. Measure: Check whether CSCWEDS.DLL is in the PATH. Normally <CSCROOT>\DLL.

20001019 CSC_CSCEDS_DLL_OPEN_FAILED Reason: The CSCWEDS.DLL could not be opened. Measure: Report the error log of this entry to Service.

Page 20: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

12 June 2004

2000101A CSC_CSCEDM_DLL_NOT_FOUND Reason: The CSCWEDM.DLL could not be found in the PATH. Normally <CSCROOT>\DLL. Measure: Check whether CSCWEDM.DLL is in the PATH. Normally <CSCROOT>\DLL.

2000101B CSC_CSCEDM_DLL_OPEN_FAILED Reason: The CSCWEDM.DLL could not be opened. Measure: Report the error log of this entry to Service.

2000101D CSC_CSCCOMM_DLL_NOT_FOUND Reason: The CSCWCOMM.DLL could not be found in the PATH (normally <CSCROOT>\DLL). Measure: Check whether CSCWCOMM.DLL is in the PATH (normally <CSCROOT>\DLL).

2000101E CSC_CSCCOMM_DLL_OPEN_FAILED Reason: The CSCWCOMM.DLL could not be opened. Measure: Report the error log of this entry to Service.

20001021 CSC_INI_WRONG_INTERFACE Reason: Wrong value for INTERFACE in Registry. Measure: Check the parameter INTERFACE in Registry.

20001022 CSC_CSCSEL_DLL_NOT_FOUND Reason: The CSCWSEL.DLL could not be found in the PATH (normally <CSCROOT>\DLL). Measure: Check whether CSCWSEL.DLL is in the PATH (normally <CSCROOT>\DLL).

Page 21: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

June 2004 13

20001023 CSC_CSCSEL_DLL_OPEN_FAILED Reason: The CSCWSEL.DLL could not be opened. Measure: Report the error log of this entry to Service.

20001025 CSC_CSCRECO_DLL_NOT_FOUND Reason: The CSCRECO.DLL could not be found in the LIBPATH (normally <CSCROOT>\DLL). Measure: Check whether CSCRECO.DLL is in the LIBPATH (normally <CSCROOT>\DLL).

20001026 CSC_CSCRECO_DLL_OPEN_FAILED Reason: The CSCRECO.DLL could not be opened. Measure: Report the error log of this entry to Service.

20001027 CSC_DQF_DLL_NOT_FOUND Reason: The DQF.DLL could not be found in the LIBPATH (normally <CSCROOT>\DLL). Measure: Check whether DQF.DLL is in the LIBPATH (normally <CSCROOT>\DLL).

20001028 CSC_DQF_DLL_OPEN_FAILED Reason: The DQF.DLL could not be opened. Measure: Report the error log of this entry to Service.

20001029 CSC_CSC1394_DLL_NOT_FOUND Reason: The CSC1394.DLL could not be found in the LIBPATH (normally <CSCROOT>\DLL). Measure: Check whether CSC1394.DLL is in the LIBPATH (normally <CSCROOT>\DLL).

Page 22: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

14 June 2004

2000102A CSC_CSC1394_DLL_OPEN_FAILED Reason: The CSC1394.DLL could not be opened. Measure: Report the error log of this entry to Service.

2000102B CSC_RECO_NOT_INSTALLED Reason: RecoStar is not, or not correct installed. Measure: Check installation of RecoStar. Check wether AI*.DLL or TIFFTOBO.DLL is in the LIBPATH (normally <CSCROOT>\DLL).

20001420 CSC_INVALID_HANDLE Reason: The handle "CscDhlPara.hCsc" given in the parameter block is invalid. Application: Check application program.

20001421 CSC_INVALID_DEVICE Reason: An illegal device number was transferred when the handle was created. Measure: Report the error log of this entry to Service.

20001422 CSC_INVALID_PINDATA Reason: The memory area, to which "pInData" points, cannot be accessed. Application: Transfer a legal memory area from the application program. Measure: If the error occurred again, report the error log of this entry to service.

20001423 CSC_INVALID_POUTDATA Reason: The memory area, to which "pOutData" points, cannot be accessed. Application: Transfer a legal memory area from the application program.

Page 23: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

June 2004 15

20001424 CSC_DEVICE_LOCKED Reason: The device handler is currently locked by another user. Application: Check application program. If necessary, repeat the command.

20001425 CSC_DEVICE_NOT_LOCKED Reason: The device handler was not locked. Application: Check application program.

20001426 CSC_INVALID_UNLOCK Reason: CscXyzUnlock was not activated by the thread which had locked the device. Application: Check application program.

20001427 CSC_ACCESS_TIMEOUT Reason: An attempt was made to access a device which is currently occupied by another user. Application: Repeat the command. Check the application program.

20003000 CSC_CANCELED Reason: The function of the device handler was cancelled from another thread with the command "CscXyzCancel". Application: This behaviour is usually correct because the application is informing the system via the CANCEL command that a particular event is not to be expected anymore.

Page 24: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

16 June 2004

20004000 CSC_TIMEOUT Reason: The function, which calls the device handler, receives a logical timeout. It is not a COM line timeout. Application: This operating system is event-controlled. It is thus possible that the expected event has not occurred within the timeout time given by the application. There is possibly no error log carried out. There are times, however, when an immediate reaction is expected from a device. If the expected reaction does not take place, an error message is returned to the application and an Entry is made in the error log. Measure: If the timeout is entered in the error log, the device should be checked.

INI error codes

20002001 INI_FUNCTION_NOT_IMPLEMENTED Reason: The function called from the device handler is not implemented in CSCWINI.DLL. Measure: Report the error log if this entry to Service.

20002003 INI_INVALID_SPEC Reason: The function specification "CscDhlPara.Spec" given in the parameter block is invalid. Measure: Report the error log of this entry to Service.

20002004 INI_INVALID_INLEN Reason: The length "CscDhlPara.InLen" of the input buffer specified in the parameter block is invalid. Measure: Report the error log of this entry to Service.

20002005 INI_INVALID_OUTLEN Reason: The length "CscDhlPara.OutLen" of the output buffer specified in the parameter block is invalid. Measure: Report the error log of this entry to Service.

Page 25: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

June 2004 17

20002422 INI_INVALID_PINDATA Reason: The memory area, to which "pInData" points, cannot be accessed. Application: Transfer a legal memory area from the application program. Measure: If the error occurred again, report the error log of this entry to Service.

20002423 INI_INVALID_POUTDATA Reason: The memory area, to which "pOutData" points, cannot be accessed. Application: Transfer a legal memory area from the application program. Measure: If the error occurred again, report the error log of this entry to Service.

20002903 INI_ID_ITEM_NOT_FOUND Reason: The keyword in Registry, specified by any function was not found. Application: If CSCWINI.DLL was called directly from the application, check whether the parameters were passed correctly from the application. Measure: Check whether the required keyword exists in Registry.

20002904 INI_KEYWORD_NOT_FOUND Reason: The keyword specified with the "CscIniScanPara" function could not be found in Registry. Application: If CSCWINI.DLL was called directly from the application, check whether the parameters were passed correctly from the application. Measure: Check whether the required keyword exists in Registry.

Page 26: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

18 June 2004

20002905 INI_INVALID_BAUDRATE Reason: An incorrect parameter for the baud rate has been entered in Registry. Measure: Enter the correct baud rate for the device.

20002906 INI_INVALID_DATABITS Reason: An invalid parameter for the data bit count has been entered in Registry. Measure: Enter the correct data bit count for the device.

20002907 INI_INVALID_STOPBITS Reason: An invalid parameter for the number of stopbits has been entered in Registry. Measure: Enter the correct number of stopbits for the device.

20002908 INI_INVALID_PARITY Reason: Invalid parameters for the parity check have been entered in Registry. Measure: Enter the correct parameters for the parity check for the device.

20002909 INI_INVALID_PROTOCOL Reason: Invalid parameters for the transmission protocol have been entered in Registry. Measure: Enter the correct parameters for the transmission protocol for the device.

2000290A INI_INVALID_VALUE Reason: The assigned value is invalid. Measure: Check Registry.

Page 27: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Global error codes

June 2004 19

2000290B INI_INVALID_ROOT Reason: Invalid or not defined value for the environment variable CSCROOT. Measure: Enter the correct value in Registry/CONFIG.SYS.

2000290C INI_CONFIG_ERROR Reason: The system can´t check whether to use the Registry or CSC.INI. Measure: Check the CSC.INI for the existence of the identification item [CSCINI] and the keyword CONFIG=FILE or CONFIG=REGISTRY.

Page 28: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

20 June 2004

Page 29: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 21

Return code handler (RCH) StClass:

STCLASS_OK No error STCLASS_ERROR_RCH Error of the CSCWRCH.DLL

StCode:

20008000 RCH_INVALID_ACTIVE_PARA Reason: YES or NO are not specified for the ACTIVE parameter in Registry/CSC.INI. Application: Correct Registry/CSC.INI.

20008001 RCH_INVALID_LANGUAGE Reason: The parameter for LANGUAGE in Registry/CSC.INI is longer than 3 characters. Application: Correct Registry/CSC.INI.

20008002 RCH_INVALID_PTXTBUF Reason: The specified buffer or buffer length are invalid. Application: Check buffer definition in application program.

20008004 RCH_INVALID_TXTBUF_LEN Reason: The specified buffer or buffer length are invalid. Application: Check buffer definition in application program.

Page 30: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Return code handler (RCH)

22 June 2004

20008005 RCH_INVALID_PCSCDHLPARA Reason: The specified buffer or buffer length are invalid. Application: Check buffer definition in application program.

20008007 RCH_INVALID_STCLASS Reason: The StClass specified for analysis is 0 (zero). Application: Check STCLASS in the application program.

20008008 RCH_INVALID_FILE_ID Reason: An invalid file ID is in an error text file. Measure: Check error text files.

20008009 RCH_INVALID_TREE Reason: An invalid flag is in an error text file. Measure: Check error text files.

2000800A RCH_UNKNOWN_TXT_FILE Reason: No file could be found for a specified StClass. Measure: Check files in <CSCROOT>\RCH for completeness.

2000800B RCH_TXT_NOT_FOUND Reason: No text number could be found for a specified StClass, StCode or StWarn. Measure: Check that files in <CSCROOT>\RCH are complete and up-to-date.

Page 31: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Return code handler (RCH)

June 2004 23

2000800C RCH_ACTCODE_NOT_FOUND Reason: The flag "#" for action code was not found within a text. Measure: Check that files in <CSCROOT>\RCH are complete and up-to-date.

2000800D RCH_DEFINE_TXT_NOT_FOUND Reason: The flag "$S" for Define in human readable text was not found within a text. Measure: Check that files in <CSCROOT>\RCH are complete and up-to-date.

2000800E RCH_THREAD_TIMEOUT Reason: The thread for reading the headers of all error text files was not completed within 60 seconds. Measure: Check hardware, operating system, file system.

2000800F RCH_THREAD_CREATE_ERROR Reason: The thread for reading the headers of all error text files could not be started. Measure: Check hardware, operating system, file system.

Page 32: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

24 June 2004

Page 33: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 25

Error statistics (EST) StClass:

STCLASS_OK No error STCLASS_ERROR_EST Error of the CSCWEST.DLL

StCode:

2000B000 EST_INVALID_STCLASS Reason: An incorrect StClass value was specified in the structure ESTCNTEXIST. Perhaps the StClass does not exist in the error statistics database. Application: Check the contents of the StClass field in the structure ESTCNTEXIST. If necessary update information about available StClass values by using the function "CscEstGetCntExist".

2000B001 EST_INVALID_STCODE Reason: An incorrect StCode value was specified in the structure ESTCNTEXIST. Perhaps the StCode does not exist in the error statistics database. Application: Check the contents of the StCode field in the structure ESTCNTEXIST. If necessary update information about available StCode values by using the function "CscEstGetCntExist".

2000B002 EST_INVALID_RANGE Reason: The contents of the RangeStart field was higher than the value in the RangeEnd field of the structure ESTCNTEXIST. Application: Call this command with RangeStart <= RangeEnd.

Page 34: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Error statistics (EST)

26 June 2004

2000B003 EST_INVALID_COUNTER Reason: No record with this combination of StClass/StCode/ModId is registrated in the error statistics database. Application: Request the actual registrated error counters by using the function "CscEstGetCntExist".

2000B004 EST_INVALID_ACTIVE Reason: An invalid expression follows the keyword ACTIVE in the section [CSCEST] of the file CSC.INI/Registry. Measure: Check the file CSC.INI/Registry.

2000B005 EST_INVALID_BUF_LEN Reason: An invalid expression follows the keyword BUF_LEN in the section [CSCEST] of the file CSC.INI/Registry. Measure: Check the file CSC.INI/Registry. The decimal value after the keyword BUF_LEN in the section [CSCEST] must be between 256 and 65536.

2000B006 EST_INVALID_PCSCDHLPARA Reason: The memory location, to which the pointer "pCscDhlPara" points, cannot be accessed. Application: Check the contents of the structure ESTCNTERROR when calling the function "CscEstCountError".

2000B007 EST_BUFFER_OVERFLOW Reason: The EST DH cannot enter more errors into the internal error buffer, because the buffer is full. Application: Do not produce too many errors too fast. Measure: Increase the size of the internal buffer by using the keyword BUF_LEN in the section [CSCEST] in the file CSC.INI/Registry.

Page 35: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Error statistics (EST)

June 2004 27

2000B008 EST_THREAD_NOT_STARTED Reason: The EST DH was not able to launch the thread that cyclically clears the internal buffer. Measure: Reduce the system load or free resources to enable the start of another thread.

2000B009 EST_CORRUPT_FILE Reason: The file that contains the error statistics database is not of the expected format. Application: Reset the whole database by using the function "CscEstReset" with the specification EST_RESET_ALL. Attention: All data will be lost.

2000B00A EST_TLS_ERROR Reason: An error occurred when the EST DH tried to get a module ID from the TLS DH or the EST DH tried to flush the TLS information buffer. Measure: Check the TLS/Win installation.

2000B00C EST_CANNOT_OPEN_FILE Reason: The output file for receiving the plain text log could not be opened. Measure: Check the filename provided for the function "CscEstPrintLog".

2000B00D EST_CANNOT_WRITE_FILE Reason: The output file for receiving the plain text log could not be written to. Measure: Check the available space on the storage device or the availability of the printer, if the function "CscEstPrintLog" prints on a disk or to a printer.

2000B00E EST_OUT_OF_MEMORY Reason: The DH EST was not able to allocate enough memory for the function "CscEstPrintLog". Measure: Provide more memory (i. e. by adding more RAM or ending other processes).

Page 36: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

28 June 2004

Page 37: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 29

Transaction statistics (TRA) StClass:

STCLASS_OK No error STCLASS_ERROR_TRA Error of the CSCWTRA.DLL

StCode:

2000C000 TRA_INVALID_SELECTIONMASK Reason: The SelectionMask parameter contained an invalid value. Application: Check the contents of the SelectionMask parameter in the structure TRACNTTRANS.

2000C001 TRA_UNKNOWN_GROUPNAME Reason: The group name that was provided by the application does not exist. Perhaps the database was reset since the last call to the function "CscEstGetTransExist". Application: Check the group name and eventually reread the available group names by using the function "CscEstGetTransExist".

2000C002 TRA_OUT_OF_MEMORY Reason: The TRA DH ran into an internal memory limitation. Measure: Report the error log of this entry to Service.

2000C003 TRA_CORRUPT_NAMEFILE Reason: The information contained in the namespace file CSCTRA.INI is inconsistent. Application: Reset the whole database.

Page 38: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Transaction statistics (TRA)

30 June 2004

2000C004 TRA_SYNTAX_ERROR Reason: The parsing routine detected a syntax error in one of the TRA files. Measure: Check the *.TRA files.

2000C006 TRA_CANNOT_OPEN_FILE Reason: The output file for receiving the plain text log could not be opened. Application: Check the filename provided for the function "CscTraPrintLog".

2000C007 TRA_CANNOT_WRITE_FILE Reason: The output file for receiving the plain text log could not be written to. Measure: Check the available space on the storage device or the availability of the printer, if the function "CscTraPrintLog" prints on a disk or to a printer.

Page 39: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 31

COMM mutiplexer StClass:

STCLASS_OK No error STCLASS_ERROR_COMM Error of the CSCWCOMM.DLL

StCode:

2000FE06 COMM_INVALID_PROTOCOL Reason: The COMM reports an invalid specification for the protocol. If the error occurs with the use of LPT, then the parallel port does not meet the requirements for the selected transfer mode. Application: Use the protocol type from the COMM.H definition file when calling "CscV24Init". Measure: If the error occurs with the use of LPT, then you have to check the port configuration (e.g. for the printers TH97 and ND97 the parallel port is to be configured for ECP in the BIOS.

2000FE07 COMM_WRITE_CANCELED Reason: A COMM WRITE command is cancelled by the user. No entry is made in the error log.

2000FE08 COMM_WRITE_TIMEOUT Reason: A COMM WRITE command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 40: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

32 June 2004

2000FE09 COMM_READ_TIMEOUT Reason: A COMM READ command could not be executed in the specified monitoring time. - Line connection, power supply not okay. - Device faulty. - Software configuration faulty. Application: Repeat the command if necessary. Measure: Check the line connection, power supply. Check device (selftest, light-emitting diode, test program).

2000FE0A COMM_READ_CANCELED Reason: A COMM READ command is cancelled by the user. No entry is made in the error log.

2000FE0B COMM_PARITY_ERROR Reason: The COMM driver reports a parity error. The received data block is invalid. Measure: If the error recurs, check the hardware.

2000FE0C COMM_GENERAL_FAILURE Reason: The COMM driver reports a general error. Measure: Check the hardware and report the error log of this entry to Service.

2000FE0F COMM_PROTOCOL_VIOLATION Reason: The peripheral device did not answer in a specified monitoring time as expected. Reasons may be: a) Peripheral not attached or switched off b) Peripheral was switched off while a connection was open c) Cable or peripheral hardware problem Application: Close the device and open it again. Measure: Check if one of the reasons a), b) and c) is responsible for the problem. If you can exclude these possibilities report the error log of this entry to Service.

Page 41: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

June 2004 33

2000FE13 COMM_CHAN_NOT_INITIALIZED Reason: The channel was not initialized. Application: Check the application program. Measure: Initialize the channel before using it.

2000FE14 COMM_ACCESS_DENIED Reason: Access to port denied. The parallel port is already assigned exclusively by an appropriate driver command (e.g. IOCTL_PAR_CSC_SELECT_ECP_RESERVE). Measure: Fix the configuration or application error.

2000FE16 COMM_BREAK Reason: The COMM driver reports a break. Measure: If the error recurs, check the hardware.

2000FE7A COMM_OVERRUN_ERROR Reason: The COMM driver reports a overrun error. Measure: Check the hardware and report the error log of this entry to Service.

2000FE7B COMM_FRAMING_ERROR Reason: The COMM driver reports a framing error. Measure: Check the hardware and report the error log of this entry to Service.

Page 42: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

34 June 2004

2000FE85 COMM_DRIVER_OPEN_FAILED Reason: The COMM driver could not be opened. Measure: Check serial device entry in Registry/CSC.INI. Check if additional COMM drivers are installed (e.g. "ROCKET.SYS"). Check COMM Hardware.

2000FE89 COMM_INVALID_PTXDATA Reason: The pointer "pTxData" is illegal. Application: Transfer a legal pointer to the multiplexer in the application program.

2000FE8B COMM_INVALID_OPEN_SPEC Reason: The called function is invalid for the used CscCommOpen specification. Application: Use the definition in the COMM.H definition file.

2000FE8C COMM_NO_STX Reason: The peripheral device does not return an STX. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE8D COMM_NO_ETX Reason: The peripheral device does not return an ETX. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 43: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

June 2004 35

2000FE8E COMM_INVALID_BLK_LEN Reason: The expected block length does not agree with the transmitted block length. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE8F COMM_INVALID_BLK_ID Reason: The block ID is invalid. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE90 COMM_INVALID_DEV_ID Reason: The received device ID does not agree with the transmitted device ID. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE91 COMM_INVALID_COMMAND Reason: The received command specification does not agree with the transmitted command specification. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 44: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

36 June 2004

2000FE92 COMM_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid (only ACK and NAK are valid). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE93 COMM_MAX_TX_RETRIES Reason: The maximum number of repeat transmissions has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE94 COMM_MAX_RX_RETRIES Reason: The maximum number of receive repeats has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE95 COMM_PROTOCOL_TX_TIMEOUT Reason: The total protocol monitoring time during transmission has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 45: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

June 2004 37

2000FE96 COMM_PROTOCOL_RX_TIMEOUT Reason: The total protocol monitoring time during receive has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE97 COMM_PROTOCOL_POLL_TIMEOUT Reason: The busy time transmitted from the peripheral device is exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE98 COMM_PROTOCOL_CANCELED Reason: The protocol was cancelled. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the application program.

2000FE9C COMM_INVALID_TXDATA_LEN Reason: The length in TxData is 0 (zero). Application: Specify a legal length.

2000FE9D COMM_CSCISO_DLL_NOT_FOUND Reason: The CSCWISO.DLL could not be found in the PATH (normally <CSCROOT>\DLL). Measure: Check whether CSCWISO.DLL is in the PATH (normally <CSCROOT>\DLL).

Page 46: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

38 June 2004

2000FE9E COMM_CSCISO_DLL_OPEN_FAILED Reason: The CSCWISO.DLL could not be opened. Measure: Report the error log of this entry to Service.

2000FE9F COMM_CSCUSB_DLL_NOT_FOUND Reason: The CSCWUSB.DLL could not be found in the PATH (normally <CSCROOT>\DLL). Measure: Check whether CSCWUSB.DLL is in the PATH (normally <CSCROOT>\DLL).

2000FEA0 COMM_CSCUSB_DLL_OPEN_FAILED Reason: The CSCWUSB.DLL could not be opened. Measure: Report the error log of this entry to Service.

2000FEB0 COMM_INVALID_DRIVER_CONF Reason: A configured driver (COM, CH, LPT) gets not the state running. Measure: Report the error log of this entry to Service.

2000FEE0 COMM_P2_TX_NO_RESP_ON_ENQ Reason: The command could not be transmitted because the peripheral device did not answer. Measure: Check the hardware.

2000FEE1 COMM_P2_TX_INVALID_RESP_ON_ENQ Reason: The command could not be transmitted because the peripheral device did not answer as expected. Application: Initialize the device and repeat the transaction. Measure: Check the hardware.

Page 47: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

June 2004 39

2000FEE2 COMM_P2_TX_NAK_RECEIVED Reason: The command could not be transmitted because the peripheral device announced that it is busy. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware if necessary.

2000FEE3 COMM_P2_TX_NO_VALID_RESP_ON_TEXT Reason: The command could not be completely transmitted because the peripheral device did not answer as expected. Application: Initialize the device and repeat the transaction. Measure: Check the hardware.

2000FEE4 COMM_P2_TX_MAX_RETRIES Reason: The command could not be completely transmitted because the maximum number of repeat transmissions has been reached. Application: Initialize the device and repeat the transaction. Measure: Check the hardware.

2000FEE5 COMM_P2_TX_ABORTED Reason: The command could not be completely transmitted because the device asked for the termination of the transmission. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware if necessary.

Page 48: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

40 June 2004

2000FEE6 COMM_P2_RX_CMD_TIMEOUT Reason: The peripheral device did not answer in the specified monitoring time of the command. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FEE7 COMM_P2_RX_ISO_TIMEOUT Reason: The response of the device has not been completely received because one of the internal protocol monitoring times has been exceeded. Application: Initialize the device and repeat the transaction. Measure: Check the hardware.

2000FEE8 COMM_P2_RX_INVALID_HEADER Reason: The header of the response is invalid. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FEE9 COMM_P2_RX_INVALID_DEVICE_ID Reason: The received device ID does not agree with the transmitted device ID. Application: Repeat the command and if necessary initialize the device again beforehand Measure: Check the hardware.

Page 49: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

June 2004 41

2000FEEA COMM_P2_RX_INVALID_CMD_ID Reason: The received command ID does not agree with the transmitted device ID. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FEEB COMM_P2_RX_INVALID_CMD_SPEC Reason: The received command specification does not agree with the transmitted command specification. Application: Repeat the command and if necessary initialize the device again beforehand Measure: Check the hardware.

2000FEEC COMM_P2_RX_CRC_ERROR Reason: The response of the device has not been completely received because one of the transmission blocks could not be received without faults. Application: Initialize the device and repeat the transaction Measure: Check the hardware.

2000FEED COMM_P2_NO_CMD_ACTIVE Reason: A cancel command has been called while no command was active. Application: Call the cancel command only when a cancelable command is active.

2000FEEF COMM_P2_CMD_NOT_CANCABLE Reason: A cancel command has been called while a not cancelable command was active. Application: Call the cancel command only when a cancelable command is active.

Page 50: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

COMM mutiplexer

42 June 2004

2000FEF0 COMM_P2_CMD_STILL_ACTIVE Reason: The command could not be executed because another command was still active Application: Repeat the command and if necessary initialize the device again beforehand.

2000FEF1 COMM_P2_CMD_CANCELLED Reason: The command was aborted by the user. No entry will be made in the error log.

2000FEF2 COMM_P2_CANCEL_STILL_ACTIVE Reason: The command could not be executed because a cancel command was still active. Application: Repeat the command and if necessary initialize the device again beforehand.

2000FEF3 COMM_P2_CANCEL_NOT_SUCCESSFUL Reason: A cancel command could not be executed. Application: Repeat the cancel command.

2000FEF4 COMM_P2_TX_CANCEL_TIMEOUT Reason: The command could not be cancelled because an internal monitoring time has been exceeded. Application: Initialize the device and repeat the transaction. Measure: Check the hardware.

2000FEF5 COMM_P2_SYNCHRONISATION_ERROR Reason: Internal error within the CSCWISO.DLL. Measure: Report the error log of this entry to Service.

Page 51: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 43

IEEE 1394 StClass:

STCLASS_OK No error STCLASS_ERROR_1394 Error of the CSCW1394.DLL

StCode:

2000FE09 I1394_READ_TIMEOUT Reason: A IEEE 1394 read command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

2000FE0A I1394_READ_CANCELED Reason: A IEEE 1394 read command is cancelled by the user. No entry is made in the error log.

2000FE89 I1394_INVALID_PDATA Reason: The pointer "pData" is illegal. Application: Transfer a legal pointer to the device handler in the application program.

2000FE9C I1394_INVALID_DATASIZE Reason: The length in DataSize is 0 (zero). Application: Specify a legal length.

Page 52: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

44 June 2004

2000FE9D I1394_TS_DLL_NOT_FOUND Reason: The I1394_TS.DLL could not be found in the PATH. Normally <CSCROOT>\DLL. Measure: Check whether I1394_TS.DLL is in the PATH. Normally <CSCROOT>\DLL.

2000FE9E I1394_TS_DLL_OPEN_FAILED Reason: The I1394_TS.DLL could not be opened. Measure: Report the error log of this entry to Service.

2000FE9F I1394_UB_DLL_NOT_FOUND Reason: The I1394_UB.DLL could not be found in the PATH. Normally <CSCROOT>\DLL. Measure: Check whether I1394_UB.DLL is in the PATH. Normally <CSCROOT>\DLL.

2000FEA0 I1394_UB_DLL_OPEN_FAILED Reason: The I1394_UB.DLL could not be opened. Measure: Report the error log of this entry to Service.

200A0020 I1394_ERROR_TIMEOUT Reason: Internal driver error: Driver responded timeout status. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 53: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 45

200A0100 I1394_ERROR_NO_MEMORY Reason: Internal driver error: Out of memory. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200A0210 I1394_ERROR_INVALID_DEVICE_STATE Reason: Internal driver error: Device is not in working state. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200A0300 I1394_ERROR_INVALID_PARAMETER Reason: Internal driver error: Invalid parameter. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200A0305 I1394_ERROR_INVALID_BUFFER_SIZE Reason: Internal driver error: Size of buffer is invalid. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 54: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

46 June 2004

200A8001 I1394_ERROR_DEVICE_NOT_FOUND Reason: Internal driver error: Device not found. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200A8010 I1394_ERROR_NO_SUCH_DEV_INSTANCE Reason: Internal driver error: No such device instance. The IEEE 1394 driver could not be opened. Application: Repeat the command if necessary. Measure: Check device entry in Registry. Check if IEEE 1394 drivers are installed. Check IEEE 1394 Hardware. Check the hardware if necessary.

200B0100 I1394_ERROR_ABORTED Reason: Internal driver error: The operation was cancelled/aborted by the miniport because it could not be performed (for example there is a critical hardware error that halted the adapter, or the miniport is unloading). Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0200 I1394_ERROR_ADAPTER Reason: Internal driver error: A non-critical error occurred on the adapter that caused the request to fail. The error affected only this operation and the adapter is otherwise functioning normally. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 55: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 47

200B0250 I1394_ERROR_ALREADY_OPEN Reason: Internal driver error: The application has already opened the specified adapter. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0270 I1394_ERROR_BR_LIMIT Reason: Internal driver error: The operation was cancelled because more bus resets occurred than the operation could tolerate. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0300 I1394_ERROR_BUS_RESET Reason: Internal driver error: The operation was cancelled because a 1394 bus reset took place. For example a queued asynchronous transaction must be failed because the target NodeID might not be the same after the bus reset. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0350 I1394_ERROR_CONFLICT Reason: Internal driver error: The operation could not be completed because there was a conflict. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 56: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

48 June 2004

200B0370 I1394_ERROR_CRC Reason: Internal driver error. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0400 I1394_CRITICAL_ADAPTER_ERROR Reason: Internal driver error: A critical error occurred on the adapter that caused the request to fail. The adapter is not fully functional and the class driver should take corrective actions (closing an isochronous channel, resetting the adapter etc). Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0500 I1394_ERROR_DEVICE_BUSY Reason: Internal driver error: The operation requested failed because the local adapter is busy. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0572 I1394_ERROR_DMA Reason: Internal driver error. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 57: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 49

200B0600 I1394_DRIVER_INTERNAL_ERROR Reason: Internal driver error: The driver detected a bug in its execution logic (through assertions or sanity checks), and could not complete the operation. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0639 I1394_ERROR_DUPLICATE_CHANNEL Reason: Internal driver error: The isochronous channel number is already in use. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0645 I1394_ERROR_FIFO_OVERRUN Reason: Internal driver error: An isochronous operation failed because of a FIFO overrun. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0658 I1394_ERROR_FIFO_UNDERRUN Reason: Internal driver error: An isochronous operation failed because of a FIFO underrun. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 58: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

50 June 2004

200B0671 I1394_ERROR_GAP_COUNT Reason: Internal driver error: The class driver detected that not all the self?ID packets that were transmitted after the last bus reset contained the same value in their gap_count field. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B06B2 I1394_ERROR_INCORRECT_RESPONSE Reason: Internal driver error: An outgoing response packet is not valid. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0700 I1394_ERROR_INSUFFICIENT_RESOURCES Reason: Internal driver error: An operation failed due to some lack of resources other than memory. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0900 I1394_ERROR_INVALID_CHANNEL_TYPE Reason: Internal driver error: The operation requested is not applicable to the channel type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 59: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 51

200B0A00 I1394_ERROR_INVALID_CHANNEL_STATE Reason: Internal driver error: The operation requested is not possible at the channel's current operating state. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0C00 I1394_ERROR_INVALID_HANDLE Reason: Internal driver error: The miniport adapter handle passed to the miniport does not identify one of its adapters. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0D00 I1394_ERROR_INVALID_ISOCHRONOUS_BUFFERS Reason: Internal driver error: A validation check on a number of isochronous buffers failed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0D47 I1394_ERROR_INVALID_OFFSET Reason: Internal driver error: The 1394 address space offset specified was above the highest 1394 offset (0xFFFFFFFFFFFF), or the address range specified spanned the highest 1394 offset. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 60: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

52 June 2004

200B0F00 I1394_ERROR_INVALID_REQUEST Reason: Internal driver error: The request passed to the miniport was invalid, and there was no other more specific error status for this operation. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0F50 I1394_ERROR_INVALID_RESPONSE Reason: Internal driver error: An response packet was received that was invalid for the corresponding transaction request, or the class driver detected that an outgoing response is not complying with the rules set by the standard with regards to header information (destination NodeID, transaction code, data length). Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B0F73 I1394_ERROR_LOCK_FAILED Reason: Internal driver error. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1070 I1394_ERROR_NOT_FOUND Reason: Internal driver error: The requested item was not found. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 61: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 53

200B1100 I1394_ERROR_NOT_IMPLEMENTED Reason: Internal driver error: The request passed to the miniport was valid, the adapter hardware supports the functionality but the miniport does not implement this feature. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1200 I1394_ERROR_NOTSUPPORTED Reason: Internal driver error: The request passed to the driver was valid, but the driver software or the adapter itself does not support the required functionality. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1300 I1394_ERROR_PENDING Reason: Internal driver error: The request is queued in the miniport and will be processed asynchronously. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1313 I1394_ERROR_SELFID Reason: Internal driver error: The class driver detected that there was some structural/logical problem in the self?ID packets that were transmitted after the last bus reset. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 62: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

54 June 2004

200B132A I1394_ERROR_SIZE_LIMITATION Reason: Internal driver error: The request cannot be transmitted because the payload size cannot be transmitted on the path to the destination node. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1350 I1394_ERROR_SPEED_LIMITATION Reason: Internal driver error: The request cannot be transmitted because the payload size is greater than the maximum allowed for the adapter's speed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1409 I1394_ERROR_TOPOLOGY Reason: Internal driver error: The class driver detected that although there was no structural/logical problem in the self?ID packets that were transmitted after the last bus reset, the bus topology described by them is not valid. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1433 I1394_ERROR_TRANSACTION_FAILED Reason: Internal driver error: A transaction request has been sent, its corresponding response was received, and the response code indicated that the transaction was not completed successfully. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 63: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 55

200B1450 I1394_ERROR_UNSOLICITED_RESPONSE Reason: Internal driver error: An application tried to transmit a response that did not have a matching request. This can happen if the response is indeed unsolicited, or if the application was so late that the request was timeout and an additional split transaction timeout occurred and the entry was cleared. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200B1500 I1394_ERROR_UNSUCCESSFUL Reason: Internal driver error: The requested operation failed and there is no other more specific error status for the situation. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0001 I1394_FAILED Reason: Internal driver error: Operation failed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0010 I1394_ERROR_NOT_SUPPORTED Reason: Internal driver error: Operation not supported. Application: Check application.

Page 64: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

56 June 2004

200E0011 I1394_ERROR_VERSION_MISMATCH Reason: Internal driver error: API Version does not match. Application: Check application.

200E0030 I1394_ERROR_REJECTED Reason: Internal driver error: Operation rejected. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0110 I1394_ERROR_POOL_EMPTY Reason: Internal driver error: Packet pool empty. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0200 I1394_ERROR_DEVICE_NOT_PRESENT Reason: Internal driver error: Device is removed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0220 I1394_ERROR_INVALID_POWER_STATE Reason: Internal driver error: Requested power state transition not allowed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 65: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 57

200E0280 I1394_ERROR_POWER_DOWN Reason: Internal driver error: Operation rejected, device is powered down. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0302 I1394_ERROR_INVALID_IOCTL Reason: Internal driver error: Invalid IO control code. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0304 I1394_ERROR_INVALID_BYTE_COUNT Reason: Internal driver error: Requested byte count doesn´t match buffer size. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0310 I1394_ERROR_INVALID_INBUFFER Reason: Internal driver error: Input buffer too small. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 66: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

58 June 2004

200E0320 I1394_ERROR_INVALID_OUTBUFFER Reason: Internal driver error: Output buffer too small. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0340 I1394_ERROR_BOUND_TO_THIS Reason: Internal driver error: Handle already used by an object of this type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0341 I1394_ERROR_BOUND_TO_OTHER Reason: Internal driver error: Handle already used by an object of another type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0342 I1394_ERROR_NOT_BOUND Reason: Internal driver error: Handle not associated with required object. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 67: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 59

200E0350 I1394_ERROR_BUS_RESET_OCCURED Reason: Internal driver error. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0351 I1394_ERROR_INVALID_GEN_COUNT Reason: Internal driver error. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0400 I1394_ERROR_INVALID_CONFIG_TYPE Reason: Internal driver error: Invalid configuration info type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0401 I1394_ERROR_INVALID_INFO_TYPE Reason: Internal driver error: Invalid local host info type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 68: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

60 June 2004

200E0402 I1394_ERROR_INVALID_PROP_TYPE Reason: Internal driver error: Invalid local host property type. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0403 I1394_ERROR_INVALID_LOCK_TYPE Reason: Internal driver error: Unsupported type of lock operation. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E0404 I1394_ERROR_INVALID_SPEED Reason: Internal driver error: Unsupported speed selected. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E8002 I1394_ERROR_DEVICE_NOT_OPEN Reason: Internal driver error: Device not open. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 69: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

IEEE 1394

June 2004 61

200E8003 I1394_ERROR_WAIT_TIMEOUT Reason: Internal driver error: Request timeout interval has expired. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E8008 I1394_ERROR_INVALID_FUNCTION_PARAM Reason: Internal driver error: Invalid parameter in function call. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

200E8020 I1394_ERROR_MEM_ALLOC_FAILED Reason: Internal driver error: Memory allocation failed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 70: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

62 June 2004

Page 71: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 63

Universal serial bus (USB) StClass:

STCLASS_OK No error STCLASS_ERROR_USB Error of the CSCWUSB.DLL

StCode:

20008000 USB_FALSE_DESCRIPTOR_TYPE Reason: A unexpected descriptor was reported from the USB device. Measure: Inform system administrator.

20008001 USB_DEVICE_NOT_FOUND Reason: Device not found. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008002 USB_INSUFFICIENT_MEMORY Reason: Not enough memory available. Measure: Inform system administrator.

20008003 USB_ENDPOINT_NOT_FOUND Reason: It was no endpoint found in the descriptor. Measure: Inform system administrator.

Page 72: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

64 June 2004

20008004 USB_CREATE_DEVICE_LIST_FAILED Reason: The creation of the list of USB devices failed. Measure: Inform system administrator.

2000E001 USB_I_WIN_ERR Reason: The operating system returned an error. Measure: Check the system error code in the log file. If necessary, inform system administrator.

2000E002 USB_I_INSTUSB_ERR Reason: The InstUsb tool returned an error. Measure: Check the error entry that has been logged by InstUsb. If necessary, inform system administrator.

2000FE09 USB_READ_TIMEOUT Reason: A USB read command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

2000FE0A USB_READ_CANCELED Reason: A USB READ command is cancelled by the user. No entry is made in the error log.

2000FE89 USB_INVALID_PDATA Reason: The pointer "pData" is illegal. Application: Transfer a legal pointer to the device handler in the application program.

Page 73: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 65

2000FE9C USB_INVALID_DATASIZE Reason: The length in DataSize is 0 (zero). Application: Specify a legal length.

E0000001 USBIO_ERR_CRC Reason: A CRC error has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000002 USBIO_ERR_BTSTUFF Reason: A bit stuffing erro has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000003 USBIO_ERR_DATA_TOGGLE_MISMATCH Reason: A DATA toggle mismatch (DATA0/DATA1 tokens) has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000004 USBIO_ERR_STALL_PID Reason: A STALLPID has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000005 USBIO_ERR_DEV_NOT_RESPONDING Reason: The USB device is not responding. This error is reported by the USB host controller driver. Measure: Inform system administrator.

Page 74: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

66 June 2004

E0000006 USBIO_ERR_PID_CHECK_FAILURE Reason: A PID check has failed. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000007 USBIO_ERR_UNEXPECTED_PID Reason: A nunexpected PID has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000008 USBIO_ERR_DATA_OVERRUN Reason: A data overrun error has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000009 USBIO_ERR_DATA_UNDERRUN Reason: A data underrun error has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E000000A USBIO_ERR_RESERVED1 Reason: This error code is reserved by the USB host controller driver. Measure: Inform system administrator.

E000000B USBIO_ERR_RESERVED2 Reason: This error code is reserved by the USB host controller driver. Measure: Inform system administrator.

Page 75: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 67

E000000C USBIO_ERR_BUFFER_OVERRUN Reason: A buffer overrun has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E000000D USBIO_ERR_BUFFER_UNDERRUN Reason: A buffer underrun has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E000000F USBIO_ERR_NOT_ACCESSED Reason: A data buffer was not accessed. This error is reported by the USB host controller driver. An isochronous data buffer was scheduled too late.The specified frame number does not match the actual frame number. Measure: Inform system administrator.

E0000010 USBIO_ERR_FIFO Reason: A FIFO error has been detected. The PCI bus latency was too long. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000011 USBIO_ERR_XACT_ERROR Reason: A XACT error has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000012 USBIO_ERR_BABBLE_DETECTED Reason: A device is babbling. The data transfer phase exceeds the USB frame length. This error is reported by the USB host controller driver. Measure: Inform system administrator.

Page 76: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

68 June 2004

E0000013 USBIO_ERR_DATA_BUFFER_ERROR Reason: A data buffer error has been detected. This error is reported by the USB host controller driver. Measure: Inform system administrator.

E0000030 USBIO_ERR_ENDPOINT_HALTED Reason: The endpoint has been halted by the USB bus driver USBD. This error is reported by the USB bus driver USBD. A pipe will be halted by USBD when a data transmission error (CRC, bit stuff, DATA toggle) occurs. In order to re-enable a halted pipe a IOCTL_USBIO_RESET_PIPE request has to be issued on that pipe. Measure: Inform system administrator.

E0000100 USBIO_ERR_NO_MEMORY Reason: A memory allocation attempt has failed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000200 USBIO_ERR_INVALID_URB_FUNCTION Reason: An invalid URB function code has been passed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000300 USBIO_ERR_INVALID_PARAMETER Reason: An invalid parameter has been passed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 77: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 69

E0000400 USBIO_ERR_ERROR_BUSY Reason: There are data transfer requests pending for the device. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000500 USBIO_ERR_REQUEST_FAILED Reason: A request has failed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000600 USBIO_ERR_INVALID_PIPE_HANDLE Reason: An invalid pipe handle has been passed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000700 USBIO_ERR_NO_BANDWIDTH Reason: There is not enough bandwidth available. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000800 USBIO_ERR_INTERNAL_HC_ERROR Reason: An internal host controller error has been detected. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000900 USBIO_ERR_ERROR_SHORT_TRANSFER Reason: A short transfer has been detected. This error is reported by the USB bus driver USBD. If the pipe is not configured accordingly a short packet sent by the device causes this error. Measure: Inform system administrator.

Page 78: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

70 June 2004

E0000A00 USBIO_ERR_BAD_START_FRAME Reason: A bad start frame has been specified. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000B00 USBIO_ERR_ISOCH_REQUEST_FAILED Reason: An isochronous request has failed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000C00 USBIO_ERR_FRAME_CONTROL_OWNED Reason: The USB frame control is currently owned. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000D00 USBIO_ERR_FRAME_CONTROL_NOT_OWNED Reason: The USB frame control is currently not owned. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000E00 USBIO_ERR_NOT_SUPPORTED Reason: The operation is not supported. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0000F00 USBIO_ERR_INVALID_CONFIGURATION_DESCRIPTOR Reason: An invalid configuration descriptor was reported by the device. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 79: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 71

E0001000 USBIO_ERR_FAILED Reason: The operation has failed. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001001 USBIO_ERR_INVALID_INBUFFER Reason: An invalid input buffer has been passed to an IOCTL operation. This error is reported by the USBIO driver. Application: Make sure the input buffer matches the type and size requirements specified for the IOCTL operation. Measure: Inform system administrator.

E0001002 USBIO_ERR_INVALID_OUTBUFFER Reason: An invalid output buffer has been passed to an IOCTL operation. This error is reported by the USBIO driver. Application: Make sure the output buffer matches the type and size requirements specified for the IOCTL operation. Measure: Inform system administrator.

E0001003 USBIO_ERR_OUT_OF_MEMORY Reason: There is not enough system memory available to complete the operation. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001004 USBIO_ERR_PENDING_REQUESTS Reason: There are read or write requests pending. This error is reported by the USBIO driver. Measure: Inform system administrator.

Page 80: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

72 June 2004

E0001005 USBIO_ERR_ALREADY_CONFIGURED Reason: The USB device is already configured. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001006 USBIO_ERR_NOT_CONFIGURED Reason: The USB device is not configured. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001007 USBIO_ERR_OPEN_PIPES Reason: There are open pipes. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001008 USBIO_ERR_ALREADY_BOUND Reason: Either the handle is already bound to a pipe or the specified pipe is already bound to another handle. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001009 USBIO_ERR_NOT_BOUND Reason: The handle is not bound to a pipe. This error is reported by the USBIO driver. The operation that has been failed with this error code is related to a pipe. Therefore, the handle has to be bound to a pipe before the operation can be executed. Measure: Inform system administrator.

Page 81: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 73

E000100A USBIO_ERR_DEVICE_NOT_PRESENT Reason: The USB device has been removed from the system. This error is reported by the USBIO driver. Application: An application should close all handles for the device. After it receives a Plug and Play notification it should perform a re-enumeration of devices. Measure: Inform system administrator.

E000100B USBIO_ERR_CONTROL_NOT_SUPPORTED Reason: The specified control code is not supported. This error is reported by the USBIO driver. Measure: Inform system administrator.

E000100C USBIO_ERR_TIMEOUT Reason: The operation has been timed out. This error is reported by the USBIO driver. Measure: Inform system administrator.

E000100D USBIO_ERR_INVALID_RECIPIENT Reason: An invalid recipient has been specified. This error is reported by the USBIO driver. Measure: Inform system administrator.

E000100E USBIO_ERR_INVALID_TYPE Reason: Either an invalid request type has been specified or the operation is not supported by that pipe type. This error is reported by the USBIO driver. Measure: Inform system administrator.

Page 82: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

74 June 2004

E000100F USBIO_ERR_INVALID_IOCTL Reason: An invalid IOCTL code has been specified. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001010 USBIO_ERR_INVALID_DIRECTION Reason: The direction of the data transfer request is not supported by that pipe. This error is reported by the USBIO driver. On IN pipes read requests are supported only. On OUT pipes write requests are supported only. Measure: Inform system administrator.

E0001011 USBIO_ERR_TOO_MUCH_ISO_PACKETS Reason: The number of isochronous data packets specified in an isochronous read or write request exceeds the maximum number of packets supported by the USBIO driver. This error is reported by the USBIO driver. Note that the maximum number of packets allowed per isochronous data buffer can be adjusted by means of the registry parameter MaxIsoPackets. Measure: Inform system administrator.

E0001012 USBIO_ERR_POOL_EMPTY Reason: The memory resources are exhausted. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001013 USBIO_ERR_PIPE_NOT_FOUND Reason: The specified pipe was not found in the current configuration. This error is reported by the USBIO driver. Note that only endpoints that are included in the current configuration can be used to transfer data. Measure: Inform system administrator.

Page 83: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 75

E0001014 USBIO_ERR_INVALID_ISO_PACKET Reason: An invalid isochronous data packet has been specified. This error is reported by the USBIO driver. An isochronous data buffer contains an isochronous data packet with invalid Offset and/or Length parameters. Measure: Inform system administrator.

E0001015 USBIO_ERR_OUT_OF_ADDRESS_SPACE Reason: There are not enough system resources to complete the operation. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001016 USBIO_ERR_INTERFACE_NOT_FOUND Reason: The specified interface was not found in the current configuration or in the configuration descriptor. This error is reported by the USBIO driver. Note that only interfaces that are included in the current configuration can be used. Measure: Inform system administrator.

E0001017 USBIO_ERR_INVALID_DEVICE_STATE Reason: The operation cannot be executed while the USB device is in the current state. This error is reported by the USBIO driver. It is not allowed to submit requests to the device while it is in a power down state. Measure: Inform system administrator.

E0001018 USBIO_ERR_INVALID_PARAM Reason: An invalid parameter has been specified with an IOCTL operation. This error is reported by the USBIO driver. Measure: Inform system administrator.

Page 84: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

76 June 2004

E0001019 USBIO_ERR_DEMO_EXPIRED Reason: The evaluation interval of the USBIO DEMO version has expired. This error is reported by the USBIO driver. The USBIO DEMO version is limited in runtime. After the DEMO evaluation period has expired every operation will be completed with this error code. Application: After the system is rebooted the USBIO DEMO driver can be used for another evaluation interval. Measure: Inform system administrator.

E000101A USBIO_ERR_INVALID_POWER_STATE Reason: An invalid power state has been specified. This error is reported by the USBIO driver. Note that it is not allowed to switch from one power down state to another. Application: The device has to be set to D0 before it can be set to another power down state. Measure: Inform system administrator.

E000101B USBIO_ERR_POWER_DOWN Reason: The device has entered a power down state. This error is reported by the USBIO driver. When the USB device leaves power state D0 and enters a power down state then all pending read and write requests will be cancelled and completed with this error status. Application: If an application detects this error status it can re-submit the read or write requests immediately. The requests will be queued by the USBIO driver internally. Measure: Inform system administrator.

E000101C USBIO_ERR_VERSION_MISMATCH Reason: The API version reported by the USBIO driver does not match the expected version. This error is reported by the USBIO C++ class library USBIOLIB. Measure: Inform system administrator.

Page 85: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 77

E000101D USBIO_ERR_SET_CONFIGURATION_FAILED Reason: The set configuration operation has failed. This error is reported by the USBIO driver. Measure: Inform system administrator.

E0001080 USBIO_ERR_VID_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support the Vendor ID reported by the USB device. Measure: Inform system administrator.

E0001081 USBIO_ERR_ISO_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support isochronous transfers. Measure: Inform system administrator.

E0001082 USBIO_ERR_BULK_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support bulk transfers. Measure: Inform system administrator.

E0001083 USBIO_ERR_EP0_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support class or vendor specific SETUP requests or the data transfer length exceeds the limit. Measure: Inform system administrator.

Page 86: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

78 June 2004

E0001084 USBIO_ERR_PIPE_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The number of endpoints active in the current configuration exceeds the limit enforced by the LIGHT version. Measure: Inform system administrator.

E0001085 USBIO_ERR_PIPE_SIZE_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The FIFO size of an endpoint of the current configuration exceeds the limit enforced by the LIGHT version. Measure: Inform system administrator.

E0001086 USBIO_ERR_CONTROL_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support control endpoints besides EP0. Measure: Inform system administrator.

E0001087 USBIO_ERR_INTERRUPT_RESTRICTION Reason: The operation has failed due to a restriction of the USBIO LIGHT version. This error is reported by the USBIO driver. The LIGHT version does not support interrupt transfers. Measure: Inform system administrator.

E0001100 USBIO_ERR_DEVICE_NOT_FOUND Reason: The specified device object does not exist. This error is reported by the USBIO C++ class library USBIOLIB. The USB device is not connected to the system or it has been removed by the user. Measure: Inform system administrator.

Page 87: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 79

E0001102 USBIO_ERR_DEVICE_NOT_OPEN Reason: No device object was opened. There is no valid handle to execute the operation. This error is reported by the USBIO C++ class library USBIOLIB. Measure: Inform system administrator.

E0001104 USBIO_ERR_NO_SUCH_DEVICE_INSTANCE Reason: The enumeration of the specified devices has failed. There are no devices of the specified type available. This error is reported by the USBIO C++ class library USBIOLIB. Measure: Inform system administrator.

E0001105 USBIO_ERR_INVALID_FUNCTION_PARAM Reason: An invalid parameter has been passed to a function. This error is reported by the USBIO C++ class library USBIOLIB. Measure: Inform system administrator.

E0001106 USBIO_ERR_LOAD_SETUP_API_FAILED Reason: The library setupapi.dll could not be loaded. This error is reported by the USBIO C++ class library USBIOLIB. The Setup API that is exported by the system-provided setupapi.dll is part of the Win32 API. It is available in Windows 98 and later systems. Measure: Inform system administrator.

E0002000 USBIO_ERR_SET_CONFIG_FAILED Reason: The set configuration request has failed. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 88: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

80 June 2004

E0003000 USBIO_ERR_USBD_BUFFER_TOO_SMALL Reason: The buffer is too small. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0004000 USBIO_ERR_USBD_INTERFACE_NOT_FOUND Reason: The interface was not found. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0005000 USBIO_ERR_INVALID_PIPE_FLAGS Reason: Invalid pipe flags have been specified. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0006000 USBIO_ERR_USBD_TIMEOUT Reason: The operation has been timed out. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0007000 USBIO_ERR_DEVICE_GONE Reason: The USB device is gone. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0008000 USBIO_ERR_STATUS_NOT_MAPPED Reason: This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 89: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

June 2004 81

E0010000 USBIO_ERR_CANCELED Reason: The operation has been cancelled. This error is reported by the USB bus driver USBD. If the data transfer requests pending on a pipe are aborted by means of IOCTL_USBIO_ABORT_PIPE or CancelIo then the operations will be completed with this error code. Measure: Inform system administrator.

E0020000 USBIO_ERR_ISO_NOT_ACCESSED_BY_HW Reason: The isochronous data buffer was not accessed by the USB host controller. This error is reported by the USB bus driver USBD. An isochronous data buffer was scheduled too late. The specified frame number does not match the actual frame number. Measure: Inform system administrator.

E0030000 USBIO_ERR_ISO_TD_ERROR Reason: The USB host controller reported an error in a transfer descriptor. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0040000 USBIO_ERR_ISO_NA_LATE_USBPORT Reason: An isochronous data packet was submitted in time but failed to reach the USB host controller in time. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

E0050000 USBIO_ERR_ISO_NOT_ACCESSED_LATE Reason: An isochronous data packet was submitted too late. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 90: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Universal serial bus (USB)

82 June 2004

E8001000 USBIO_ERR_INSUFFICIENT_RESOURCES Reason: There are not enough resources available to complete the operation. This error is reported by the USB bus driver USBD. Measure: Inform system administrator.

Page 91: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 83

DFU / DFUX Loader (DFU) StClass:

STCLASS_OK No error STCLASS_ERROR_DFU Error of the CSCWDFU.DLL

StCode:

20009000 DFU_ERR_DEVICE_IS_NOT_DOWNLOAD_CAPABLE Reason: Device is not download capable. Measure: Inform system administrator

20009001 DFU_ERR_DEVICE_IS_NOT_UPLOAD_CAPABLE Reason: Device is not upload capable. Measure: Inform system administrator

20009002 DFU_ERR_OPENING_FIRMWARE_FILE Reason: Could not open firmware file. Measure: Inform system administrator

20009003 DFU_ERR_READING_FIRMWARE_FILE Reason: Could not read firmware file. Measure: Inform system administrator

Page 92: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

DFU / DFUX Loader (DFU)

84 June 2004

20009004 DFU_ERR_WRITING_FIRMWARE_FILE Reason: Could not write firmware file. Measure: Inform system administrator

20009005 DFU_ERR_CORRUPT_FIRMWARE_FILE Reason: Corrupt firmware file. Measure: Inform system administrator

20009006 DFU_ERR_FALSE_SPEC_VERSION Reason: Program supports firmware up to DFU/DFUX version 1.00, only. Measure: Inform system administrator

20009007 DFU_ERR_NO_VALID_DFU_SIGNATURE Reason: No valid DFU signature. Measure: Inform system administrator

20009008 DFU_ERR_SUFFIX_HAS_NOT_RIGHT_SIZE Reason: Invalid suffix size for DFU/DFUX version 1.00. Measure: Inform system administrator

20009009 DFU_ERR_VID_DOES_NOT_MATCH Reason: Vendor ID of firmware file does not match device's vendor ID. Measure: Inform system administrator

Page 93: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

DFU / DFUX Loader (DFU)

June 2004 85

2000900A DFU_ERR_PID_DOES_NOT_MATCH Reason: Product ID of firmware file does not match device's product ID. Measure: Inform system administrator

2000900B DFU_ERR_FALSE_DESCRIPTOR_TYPE Reason: False descriptor type. Measure: Inform system administrator

2000900C DFU_ERR_INSUFFICIENT_MEMORY Reason: Insufficient memory. Measure: Inform system administrator

2000900D DFU_ERR_DEVICE_DOES_NOT_SUPPORT_DFU Reason: Device does not support DFU. Measure: Inform system administrator

2000900E DFU_ERR_DEVICE_NOT_READY_FOR_DOWNLOAD Reason: Device is not ready for download. Measure: Inform system administrator

2000900F DFU_ERR_DEVICE_NOT_READY_FOR_UPLOAD Reason: Device is not ready for upload. Measure: Inform system administrator

Page 94: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

DFU / DFUX Loader (DFU)

86 June 2004

20009010 DFU_ERR_DEVICE_IS_PERMANENT_BUSY Reason: evice is permanent busy. Measure: Inform system administrator

20009011 DFU_ERR_CANNOT_START_TRANSFER Reason: Can't start transfer! e.g. driver USBIO.SYS/USBIONT.SYS missing. Measure: Inform system administrator

20009012 DFU_ERR_INVALID_INTERFACE_DESCRIPTOR Reason: Invalid interface descriptor. Measure: Inform system administrator

Page 95: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 87

Power Suspend Mode Manager (PSM) StClass:

STCLASS_OK No error STCLASS_ERROR_PSM Error of the CSCWPSM.DLL

StCode:

20008000 PSM_THREAD_START_ERROR Reason: The PSM service thread could not be started (no response from started thread). Application: Terminate and start again. Measure: Stop and restart the CscService. Restart the system. Check the installation of the CSC Software.

20008001 PSM_CANT_CREATE_MUTEX Reason: A mutex object (required for thread synchronization) could not be created. Application: Terminate and start again. Measure: Stop and restart the CscService. Restart the system. Check the installation of the CSC Software.

20008002 PSM_SEL_ERROR Reason: The PSM received an error message when calling the Special Electronics Device Handler (SEL). Application: Terminate and start again. Measure: Check the system error log. Check the Special Electronics. Restart the system. Check the installation of the CSC Software.

Page 96: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

88 June 2004

Page 97: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 89

Card reader unit (IDU) StClass:

STCLASS_OK No error STCLASS_ERROR_IDU Error of the CSCWIDU.DLL

StCode:

2000E103 IDU_FRM_NO_CARTRIDGE Reason: No cartridge in the dispenser. Measure: Check the dispenser. Check configuration and file system.

2000F001 IDU_MAX_COUNT Reason: The preset maximum number of tries per command is reached. Application: React with a follow-up command depending on the command just output. Measure: Depending on the command, check the read/write head and the transport mechanism.

2000F002 IDU_TOO_LITTLE_DATA Reason: Not enough data received from IDCU. Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check connection and configuration of IDCU.

Page 98: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

90 June 2004

2000F003 IDU_INVALID_DATA Reason: Error in communication protocol with IDCU. Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check connection and configuration of IDCU.

2000F004 IDU_NO_ENQ Reason: V.24 line error. No ENQ was sent. Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware

2000F005 IDU_INVALID_RESPONSE Reason: The response from the IDCU is logically incorrect (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware

2000F006 IDU_INVALID_STATUS Reason: Invalid status (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware. Possibly more than one card in unit or light barrier defective.

Page 99: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 91

2000F007 IDU_INVALID_PARAMETER Reason: Invalid parameters with the command. Application: Check the parameters of the command. Measure: Check the [CSCIDU] parameters in the registry.

2000F009 IDU_WRONG_TYPE Reason: The parameter TYPE in registry with [CSCIDU] is incorrect. Measure: Check the parameter TYPE in registry.

2000F00B IDU_WRONG_INITPM Reason: False value for ID_PM in registry with [CSCIDU]. Application: Check the parameters for the "CscIduInit" command. Measure: Check the parameter "Card feed/Power on" in registry.

2000F00C IDU_WRONG_INITPD Reason: Wrong value for ID_PD in registry with [CSCIDU]. Application: Check the parameter for the "CscIduInit" command. Measure: Check the parameter "Card feed/Power down" in registry.

2000F00D IDU_WRONG_INITWV Reason: False value for ID_WV in registry with [CSCIDU]. Application: Check the parameters for the "CscIduInit" command. Measure: Check the parameter "Write when power failure" in registry.

Page 100: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

92 June 2004

2000F00E IDU_WRONG_INITSH Reason: False value for ID_SH in registry with [CSCIDU]. Application: Check the parameters for the "CscIduInit" command. Measure: Check the parameter "Shutter Test" in registry.

2000F00F IDU_INVALID_COMMAND Reason: Command is not available in this configuration, e.g. an attempt is made to reject a card in DIP. Application: Change application program.

2000F011 IDU_INVALID_WRITE Reason: The V.24 send command was not terminated with the correct length (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Report the error log of this entry to Service.

2000F012 IDU_NAK_RESPONSE Reason: NAK received as a response, i.e. device not ready (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware

2000F013 IDU_INVALID_CANCEL Reason: CANCEL not possible. Command has just been sent. Application: Send relevant follow-up command.

Page 101: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 93

2000F014 IDU_NESTED_CANCEL Reason: A "CscIduCancel" command has already been sent. Application: Programming error.

2000F015 IDU_NO_CARD Reason: There is no card in the unit to perform the command or the card has been removed from the device (possible manipulation). Application: Draw in card first and/or perform a "CscIduInit" command. Measure: Check the hardware.

2000F016 IDU_WRONG_INITMSS Reason: Wrong value for MSS in registry with [CSCIDU]. Measure: Check parameter MSS in registry.

2000F017 IDU_MSS_DLL_LOAD_FAILED Reason: The device handler MSS could not be loaded. Measure: Check configuration and file system.

2000F018 IDU_WRONG_INITWT Reason: Wrong value for ID_WT in registry with [CSCIDU]. Application: Check the parameters for the "CscIduInit" command. Measure: Check the parameter "Wait time when power failure" in registry.

Page 102: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

94 June 2004

2000F019 IDU_WRONG_INITRJ Reason: Wrong value for ID_RJ in registry with [CSCIDU]. Application: Check the parameters for the "CscIduInit" command. Measure: Check the parameter "Reject at power down" in registryI.

2000F01A IDU_WRONG_INIT_MAN_RECOG Reason: Wrong value for MAN_RECOG in registry with [CSCIDU]. Measure: Check the parameter MAN_RECOG in registry.

2000F01B IDU_HYB_DLL_LOAD_FAILED Reason: The device handler CSCWHYB.DLL could not be loaded. Measure: Check configuration and file system.

2000F01C IDU_WRONG_INIT_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in registry with [CSCIDU]. Measure: Check the parameters LED, LED_FLASH and LED_FREQ in registry.

2000F01D IDU_SEL_DLL_LOAD_FAILED Reason: The device handler CSCWSEL.DLL could not be loaded. Measure: Check configuration and file system.

2000F01E IDU_CIT_DLL_LOAD_FAILED Reason: The device handler CSCWCIT.DLL could not be loaded. Measure: Check configuration and file system.

Page 103: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 95

2000F020 IDU_INVALID_FRMFILE Reason: The specified firmware file does not have the correct format. Measure: Check the firmware file.

2000F021 IDU_WRONG_INIT_LOADER_CTL Reason: The parameter INIT_LOADER_CTL in the registry is incorrect. Measure: Check the parameter INIT_LOADER_CTL in the registry.

2000F022 IDU_TRA_DLL_LOAD_FAILED Reason: The device handler CSCWTRA.DLL and/or CSCWEST.DLL could not be loaded. Measure: Check configuration and file system.

2000F023 IDU_WRONG_TRANSACTION_ACTIVE Reason: The parameter TRANSACTION_ACTIVE in the registry is incorrect. Measure: Check the parameter TRANSACTION_ACTIVE in the registry.

2000F024 IDU_WRONG_TRANSACTION_TRIGGER Reason: The parameter TRANSACTION_TRIGGER in the registry is incorrect. Measure: Check the parameter TRANSACTION_TRIGGER in the registry.

2000F025 IDU_WRONG_ERROE_MAPPING Reason: The parameter ERROR_MAPPING in the registry is incorrect. Measure: Check the parameter ERROR_MAPPING in the registry.

Page 104: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

96 June 2004

2000F026 IDU_WRONG_CHIPMODE Reason: The parameter CHIPMODE in the registry is incorrect. Measure: Check the parameter CHIPMODE in the registry.

2000F027 IDU_WRONG_ENTRY_HANDLING Reason: Wrong value for ENTRY_HANDLING in registry with [CSCIDU]. Measure: Check the parameter ENTRY_HANDLING in registry.

2000F028 IDU_SWI_DLL_LOAD_FAILED Reason: The device handler CSCSWI.DLL could not be loaded. Measure: Check configuration and file system.

2000F029 IDU_EDS_DLL_LOAD_FAILED Reason: The device handler CSCEDS.DLL could not be loaded. Measure: Check configuration and file system.

2000F02A IDU_EDM_DLL_LOAD_FAILED Reason: The device handler CSCEDM.DLL could not be loaded. Measure: Check configuration and file system.

2000F02B IDU_ICM_DLL_LOAD_FAILED Reason: The device handler CSCWICM.DLL could not be loaded. Measure: Check configuration and file system.

Page 105: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 97

2000F02C IDU_WRONG_SAMMODE Reason: The parameter SAM*_MODE in the registry/CSC.INI is incorrect. SAM*_MODE is intended for SAM1_MODE, SAM2_MODE, etc.. Measure: Check the parameter SAM*_MODE in the registry/CSC.INI.

2000F02D IDU_WRONG_SAM Reason: The parameter SAM in the registry/CSC.INI is incorrect. Measure: Check the parameter SAM in the registry/CSC.INI.

2000F02E IDU_V2X_DLL_LOAD_FAILED Reason: The device handler CSCWV2X.DLL could not be loaded. Measure: Check configuration and file system.

2000F030 IDU_WRONG_INIT_ADDITION_UNIT Reason: Wrong value for ADDITIONAL_UNIT in registry with [CSCIDU]. Measure: Check the parameter ADDITIONAL_UNIT in the registry.

2000F031 IDU_MCT_DLL_LOAD_FAILED Reason: The device handler CSCWMCT.DLL could not be loaded. Measure: Check configuration and file system.

2000F032 IDU_WRONG_CARD_GRIP_LENGTH Reason: Wrong value for CARD_GRIP_LENGTH in registry with [CSCIDU]. Measure: Check the parameter CARD_GRIP_LENGTH in the registry.

Page 106: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

98 June 2004

2800E000 IDU_FRM_INVALID_COM_CODE Reason: Invalid command (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware.

2800E001 IDU_FRM_INVALID_PARAMETER Reason: Parameters not correct (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware.

2800E002 IDU_FRM_NO_COM_EXECUTE Reason: Command cannot be executed, the system has been manipulated possibly. Application: Check the logic of the command sequence. Inquire the device status/configuration.

2800E004 IDU_FRM_COM_DATA_ERROR Reason: Invalid data with a command (internal error). Application: Repeat the command and if necessary initialize the device again with the "CscIduInit" command. Measure: Check the hardware.

2800E006 IDU_FRM_MAINTENANCE_MODE Reason: The command cannot be executed, because the device is in the maintenance mode. Application: Initialize the device with the function CscIduInit() and the specification IDU_INIT_STANDARD.

Page 107: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 99

2800E009 IDU_FRM_OTHER_COM_ERROR Reason: An internal error, which cannot be precisely defined, has been encountered in the firmware of the IDCU device. Application: Initialize the firmware of the IDCU device again with the "CscIduInit" command. Measure: Check the hardware.

2800E00A IDU_FRM_CARD_JAM Reason: Card jammed (possible manipulation). Application: Try to dispense the jammed card. Measure: Remove the card and check the transport routes for foreign objects.

2800E00B IDU_FRM_SHUTTER_FAIL Reason: The sensors report an invalid position of the shutter (possible manipulation). Application: Manipulation handling. Measure: Check the shutter hardware.

2800E00C IDU_FRM_SENSOR_FAIL Reason: Sensors are defect or incorrectly dimmed. Measure: Check the hardware (possible foreign objects).

2800E00D IDU_FRM_CARD_TOO_LONG Reason: Card too long (manipulation). Application: Dispense card, do not draw it in.

Page 108: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

100 June 2004

2800E00E IDU_FRM_CARD_TOO_SHORT Reason: Card too short (manipulation). Application: Dispense card, do not draw it in.

2800E00F IDU_FRM_MEMORY_ERROR Reason: Memory error, e.g. E-PROM (internal error). Measure: Check the hardware.

2800E010 IDU_FRM_CARD_POS_MOVE Reason: Card has been shifted (manipulation). Application: Manipulation processing.

2800E011 IDU_FRM_JAM_RETRIEVE Reason: The card is jammed (possible manipulation). Application: Do not repeat command. Measure: Remove the card and check the transport routes for foreign objects.

2800E012 IDU_FRM_SW1_SW2 Reason: Shutter switch or width switch (SW1, SW2) defective. Measure: Check the switches.

2800E013 IDU_FRM_MECHANICAL Reason: An internal error, which cannot be defined precisely, has been encountered in the mechanics of the IDCU device. Measure: Check the hardware.

Page 109: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 101

2800E014 IDU_FRM_READ_PARITY Reason: The data read from the cards have the wrong parity. The card or read electronics is defective. Application: Report defective card, possibly draw card in. Measure: Check card or hardware. Clean write/read heads if required. Call customer service if problem occurs again.

2800E015 IDU_FRM_READ Reason: The card data could not be read. Application: Report defective card, possibly draw card in. Measure: Check card or hardware. Clean write/read heads if required. Call customer service if problem occurs again.

2800E016 IDU_FRM_WRITE Reason: The WRITE data is faulty on the card. Application: Report defective card, possibly draw card in. Measure: Check card or hardware. Clean write/read heads if required. Call customer service if problem occurs again.

2800E017 IDU_FRM_READ_EOF Reason: Only the end character was found on the track when read. Application: Report defective card, possibly draw card in. Measure: Check the card.

Page 110: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

102 June 2004

2800E01E IDU_FRM_POWER Reason: Power fail during a command. Measure: Check the hardware.

2800E01F IDU_FRM_DSR_OFF Reason: The DSR signal is in OFF status. Measure: Check the hardware.

2800E028 IDU_FRM_CARD_EJECT Reason: The card was removed during transport from the output position to the reject box. Application: Check application program (monitoring time for the card removal too small).

2800E070 IDU_FRM_NO_FIRMWARE Reason: There is presently no firmware loaded in the device. Application: Download the current firmware by using CscIduInit().

2800E071 IDU_FRM_INVALID_DOWNLOAD Reason: There was a problem during the download of the firmware. Application: Retry the download. Measure: Check the hardware.

Page 111: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 103

2800E100 IDU_FRM_NO_STRIPE Reason: The card data could not be read because there is no magnetic stripe or the magnetic stripe is not magnetized. Application: Report defective card, possibly draw card in. Measure: Check card or hardware. Clean write/read heads if required. Call customer service if problem occurs again.

2800E101 IDU_FRM_JAM_STACKER Reason: Card jammed (possible manipulation) in optional stacker unit. Application: Try to dispense the jammed card(s). Measure: Remove the card and check the transport routes in the stacker unit for foreign objects.

2800E102 IDU_FRM_NO_CARD_IN_STACKER Reason: No card in the dispenser. Measure: Check the dispenser.

2800E104 IDU_FRM_CARD_TRAP Reason: Card is clamped by the ID card unit. Application: Call the initialization command. Measure: Detach the trap at the ID card unit and withdraw the ID card.

2800E180 IDU_CHIP_DEFECT_CONTROLLER Reason: Communication error during chip card process. Measure: Check the IC card.

Page 112: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

104 June 2004

2800E182 IDU_CHIP_INVALID_ACTIVATION Reason: The chip card could not be activated. Measure: Check the chip card.

2800E183 IDU_CHIP_INVALID_DEACTIVATION Reason: The chip card could not be deactivated. Measure: Check the chip card.

2800E184 IDU_CHIP_COMMUNICATION Reason: An error occurred during communication with the chip card. Application: De- and reactivate the chip card. Measure: Check the chip card.

2800E185 IDU_CHIP_FORCED_INTERRUPT Reason: A forced interruption command was received from the chip card. The chip card did not perform normally; therefore, processing could not continue. Application: De- and reactivate the chip card. Measure: Check the chip card.

2800E186 IDU_CHIP_INVALID_RESPONSE Reason: An error was detected in the response from the chip card. Application: De- and reactivate the chip card. Measure: Check the chip card.

Page 113: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

June 2004 105

2800E187 IDU_CHIP_INVALID_ATR Reason: The ATR information of the card is incorrect or the card cannot be processed by the reader. For example, when the chip card protocol is not T=1 or T=0, or the chip card supply voltage is different (0 volt, 5 volt or 21 volt). Application: Abort the chip card processing.

StWarn:

20007FFB IDU_WARN_INVALID_CHIPMODE Reason: The mode for the chip card or SAM set in the registry is currently not supported. Operating the device in this mode is not possible. Instead of this mode, a default mode is used. Measure: Check the configuration of the device handler IDU.

20007FFC IDU_WARN_MEMORY_RESET Reason: The flash memory of the card reader had to be reset. This warning will only be written into the error log and not be returned with an API call. Measure: The appropriate service measure should be initiated.

20007FFD IDU_WARN_TRANSACTION Reason: The trigger level for transactions has been reached. This warning will only be written into the error log and not be returned with an API call. Measure: The appropriate service measure should be initiated.

20007FFE IDU_WARN_LED Reason: The device handler was configured to switch LEDs when waiting for an entry or removal of a card. An error occurred when accessing the SEL DH to switch the LEDs. Measure: Check the configuration of IDU and SEL device handler.

Page 114: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Card reader unit (IDU)

106 June 2004

28007FFF IDU_WARN_RESTART Reason: IDU had a temporary power failure between the last job and the current job.

Page 115: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 107

MM security system (MSS) StClass:

STCLASS_OK No error STCLASS_ERROR_MSS Error of the CSCWMSS.DLL

StCode:

2000C001 MSS_ILLEGAL_CHARACTER Reason: An invalid character was in the data transferred to a function of the MSS device handler. Application: Check application program

2000C002 MSS_INVALID_DES_KEY Reason: The entered DES key is invalid. Measure: Enter valid DES key.

2000C003 MSS_INVALID_KEYWORD Reason: An entry in the Registry/CSC.INI file in section [CSCMSS] is invalid. Measure: Check section [CSCMSS] in the Registry/CSC.INI file.

2000C004 MSS_INVALID_RESULT Reason: The data returned by the CIM-86 or MM module is not as expected. Measure: Check the hardware.

Page 116: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

MM security system (MSS)

108 June 2004

2800C800 MSS_MODULE_DATA_ERROR Reason: The CIM-86 or MM module reports that the transferred data is faulty. Measure: Check the hardware.

2800C801 MSS_MODULE_ERROR_NSN Reason: The CIM-86 or MM module reports an error when setting the NSN configuration. Measure: Check the hardware.

2800C802 MSS_MODULE_ERROR_EODT Reason: The CIM-86 or MM module reports an error when transmitting data. Measure: Check the hardware.

2800C803 MSS_MODULE_ERROR_CBS Reason: The CIM-86 or MM module reports an error when communicating that now an ec/test card comes. Measure: Check the hardware.

2800C804 MSS_MODULE_ERROR_RT3 Reason: The CIM-86 or MM module reports an error when confirming that the CIM-86 or MM module are ready for transferring the IDCU track data. Measure: Check the hardware.

2800C805 MSS_MODULE_ERROR_EOT3 Reason: The CIM-86 or MM module reports an error when communicating that the complete IDCU track has been transferred. Measure: Check the hardware.

Page 117: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

MM security system (MSS)

June 2004 109

2800C806 MSS_MODULE_ERROR_SVR Reason: The CIM-86 or MM module reports an error when requesting to communicate the verify/test result key. Measure: Check the hardware.

2800C807 MSS_MODULE_ERROR_PST Reason: The CIM-86 or MM module reports an error when requesting self-test. Measure: Check the hardware.

2800C808 MSS_MODULE_HW_ERROR_1 Reason: The CIM-86 or MM module reports the hardware error 1 during the self-test. Measure: Check the hardware.

2800C809 MSS_MODULE_HW_ERROR_2 Reason: The CIM-86 or MM module reports the hardware error 2 during the self-test. Measure: Check the hardware.

2800C80A MSS_MODULE_HW_ERROR_3 Reason: The CIM-86 or MM module reports the hardware error 3 during the self-test. Measure: Check the hardware.

2800C80B MSS_MODULE_HW_ERROR_4 Reason: The CIM-86 or MM module reports the hardware error 4 during the self-test. Measure: Check the hardware.

Page 118: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

MM security system (MSS)

110 June 2004

2800C80C MSS_MODULE_HW_ERROR_5 Reason: The CIM-86 or MM module reports the hardware error 5 during the self-test. Measure: Check the hardware.

2800C80D MSS_MODULE_HW_ERROR_6 Reason: The CIM-86 or MM module reports the hardware error 6 during the self-test. Measure: Check the hardware.

2800C80E MSS_MODULE_HW_ERROR_7 Reason: The CIM-86 or MM module reports the hardware error 7 during the self-test. Measure: Check the hardware.

2800C80F MSS_MODULE_HW_ERROR_8 Reason: The CIM-86 or MM module reports the hardware error 8 during the self-test. Measure: Check the hardware.

2800C810 MSS_MODULE_HW_ERROR_9 Reason: The CIM-86 or MM module reports the hardware error 9 during the self-test. Measure: Check the hardware.

2800CC01 MSS_MM_READ_TIMEOUT Reason: Time-out while reading the MM module via CDM. MM box not ready. Wrong PROM levels in controller of cash-out module. Incompatible software levels. Measure: Replace PROMs in cash-out controller, where necessary check module IDs (MODSEG). Have hardware (cable, plug) checked by a technician

Page 119: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

MM security system (MSS)

June 2004 111

2800CC05 MSS_MM_WRITE_TIMEOUT Reason: Time-out while writing to the MM module via CDM. MM box not ready Incompatible software levels Measure: Check module IDs (MODSEG). Have hardware (cables, plugs) checked by a technician.

2800CC08 MSS_MM_OVERRUN_ERROR Reason: Overrun error during data transfer between MM module and CDM. MM box not ready Hardware error Measure: Have hardware (cables, plugs) checked by a technician.

2800CC09 MSS_MM_PARITY_ERROR Reason: Parity error during data transfer between MM module and CDM. MM box not ready Hardware error Measure: Have hardware (cables, plugs) checked by a technician.

2800CC0A MSS_MM_FRAMING_ERROR Reason: Framing error during data transfer between MM module and CDM. MM box not ready Hardware error Measure: Have hardware (cables, plugs) checked by a technician.

2800CC0C MSS_MM_INVALID_DATA Reason: The data reported by the CDM device handler is invalid. Measure: Check the hardware.

Page 120: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

112 June 2004

Page 121: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 113

Chip card module (CCM) StClass:

STCLASS_OK No error STCLASS_ERROR_CCM Error of the CSCWCCM.DLL

StCode:

20008000 CCM_CONT_UNDEF_ERROR Reason: CCM chip card controller is not OK. Measure: If the message recurs, replace or check the chip card controller.

28008010 CCM_NO_ATR Reason: The selected chip card is not inserted or has no contact. Measure: Check if the chip card is inserted. If the chip card is inserted, clean the chip card connectors.

28008011 CCM_CHIP_NO_ANSWER Reason: The selected chip card is not inserted, clean the chip card connectors. Measure: Check if the chip card is inserted. If the chip card is inserted, clean the chip card connectors.

28008012 CCM_CHIP_NOT_SELECTED Reason: The chip card controller ist not initialized. Application: Check application program.

Page 122: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Chip card module (CCM)

114 June 2004

28008013 CCM_CONT_RAM_ERROR Reason: The RAM on the chip card controller is defect. Measure: Change the chip card controller.

28008014 CCM_CONT_CODE_ERROR Reason: The program on the chip card controller is defect. Measure: Change the chip card controller.

Page 123: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 115

Special electronics (SEL / SEV4) StClass:

STCLASS_OK No error STCLASS_ERROR_SEL Error of the CSCWSEL.DLL respectively CSCWSEV4.DLL

StCode:

20008000 SEL_INVALID_DATA Reason: Wrong data buffer structure. Application: Check application program.

20008400 SEL_INVALID_ERROR_CODE Reason: A non-interpretable error code was returned. Measure: Check the hardware connection.

20008405 SEL_CSCCNG_DLL_NOT_FOUND Reason: The CSCCNG.DLL could not be found in the LIBPATH (normally <CSCROOT>\DLL). Measure: Check whether CSCCNG.DLL is in the LIBPATH (normally <CSCROOT>\DLL).

20008407 SEL_THREAD_ERROR Reason: The thread for the asynchronous beeping could not be started. Measure: Report the error log of this entry to service,

Page 124: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

116 June 2004

20008408 SEL_QUEUE_FULL Reason: The device handlers queue for the asynchronous beeps is full. Further CscSelSwSignal() commands cannot be processed until the beeping thread has processed one or more beeps. Application: Do not call CscSelSwSignal too many times too fast.

20008409 SEL_WRONG_READY_IND_SYNCRO Reason: Wrong value for READY_IND_SYNCRO in Registry/CSC.INI at [CSCSEL]. Measure: Check the parameter READY_IND_SYNCRO in file Registry/CSC.INI.

20008410 SEL_ASKIM_START_ERROR Reason: Anti Skimming is configured in the registry file but the SEL-DH could not establish a connection to the ASKIM-Hardware. The ALARM line of the ASKIM Module must be connected to one of the reserve-input ports (RSRVI1 or RSRVI2) of the SEL. The ALARM_ENABLE line must be connected to one of the reserve output ports (RSRVO1 or RSRVO2) or to a door magnet port (MAGDOOR1, MAGDOOR2 or MAGDOOR3). Measure: Check the registry. Assign ANTI_SKIMMING to the SEL ports, the ASKIM module is connected to.

2000A001 SEV4_CSE_DEV_NOT_AVAILABLE Reason: The Special Electronic Version 4 (SEV4) may consist of two independent USB devices, the Central Special Electronic (CSE) and a Customer Connection Box (CCB). The CSE part (Central Special Electronic) of the SEV4 is not available. Application: Ensure that the selected CSE Port is correct. Measure: Check key CSE_SUPPORT in the registry section CSCSEV4.

Page 125: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

June 2004 117

2000A002 SEV4_CCB_DEV_NOT_AVAILABLE Reason: The Special Electronic Version 4 (SEV4) may consist of two independent USB devices, the Central Special Electronic (CSE) and a Customer Connection Box (CCB). The CCB part (Customer Connection Box) of the SEV4 is not available. Application: Ensure that the selected CCB Port is correct. Measure: Check key CCB_SUPPORT in the registry section CSCSEV4.

2000A003 SEV4_CSE_PORT_NOT_AVAILABLE Reason: The selected CSE-Port of the SEV4 is not available. Application: Ensure that the selected port is correct. Measure: Check the configuration of this port in the registry file.

2000A004 SEV4_CCB_PORT_NOT_AVAILABLE Reason: The selected port of the customer connection box (CCB) is not available. Application: Ensure that the selected port is correct. Measure: Check the configuration of this port in the registry file.

2000A005 SEV4_ILLEGAL_CSE_PORT Reason: The selected CSE-Port is not part of the SEV4. Application: Check the application program. Ensure that the selected port is correct.

2000A006 SEV4_ILLEGAL_CCB_PORT Reason: The selected CCB-Port is not part of the SEV4. Application: Check the application program. Ensure that the selected port is correct.

Page 126: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

118 June 2004

2000A007 SEV4_ILLEGAL_PARAMETER Reason: The application passed a command to the SEV4 Device Handler with an illegal parameter. Application: Check the application program. Use the parameter and command structures predefined in SEV4.H.

2000A008 SEV4_ILLEGAL_SOUND_PARA Reason: The application tried to initiate a sound output with illegal parameter. Application: Check the application program. Ensure that only one of the predefined frequencies is used.

2000A009 SEV4_ILLEGAL_MEI_PARA Reason: The application tried to switch a Media Entry Indicator (MEI), but the function was called with an illegal parameter. Application: Check the application program. Ensure that only one of the predefined flashing frequencies and a valid MEI number is used.

2000A010 SEV4_WRONG_KEY_PARITY Reason: One of the DES keys loaded into the SEV4 or one of the keys in the EE-PROM (TK) has a wrong parity. Application: Check the DES keys transferred to the SEV4 device handler and/or reload the TK. Measure: Check the hardware.

2000A020 SEV4_INVALID_LCD_CONFIG Reason: The configuration of an LCD light is not correct. Measure: Check the configuration in registry or ini-file.

Page 127: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

June 2004 119

2000A021 SEV4_INVALID_LOGO_CONFIG Reason: The configuration of a LOGO light is not correct. Measure: Check the configuration in registry or ini-file.

2000A022 SEV4_INVALID_RESRET_CONFIG Reason: The configuration of a Reserve Input is not correct. Measure: Check the configuration in registry or ini-file.

2000A023 SEV4_INVALID_MEI_CONFIG Reason: The application tried to switch the status of a not configured MEI. Application: Check the application program and the configuration of the selected MEI. Measure: Check the configuration in regestry- or ini-file.

2000A024 SEV4_INVALID_MEI_FLASHING Reason: The application program tried to set more than two MEI ports to flash asynchronous or it used an invalid flash frequency. Asynchronous flashing is only possible if exactly two MEI's selected. Application: Check the application program. Ensure that the selected port and all supplied parameters are correct. Measure: Report the error log of this entry to Service.

Page 128: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

120 June 2004

2000A030 SEV4_INVALID_DATA Reason: The response of the SEV4 firmware contained invalid data. Application: Check the application program. Ensure that the selected port and all supplied parameters are correct. Measure: Check the SEV4 hardware. Reload the SEV4 firmware if necessary.

2000A040 SEV4_THREAD_ERROR Reason: The SEV4-DH can not execute the internal status thread. Measure: Report the error log of this entry to Service.

2000A050 SEV4_EVENT_NO_RESOURCE Reason: The application performed the command CscSeV4RegisterEvent. The SEV4-DH has resources for max. 64 event user. Application: To many threads are registered as event user. Call CscSeV4Deregister to free resources. Measure: Report the error log of this entry to Service.

2000A051 SEV4_EVENT_INVALID_USER Reason: The application called CscSeV4Deregister or CscSeV4WaitForStatusEvent from a not registered thread. Application: Check the application program. The functions CscSeV4RegisterEvent, CscSeV4DeregisterEvent and CscSeV4WaitForStatusEvent must be call from the same thread. Measure: Fehler-Log dieses Eintrags an den TKD melden.

Page 129: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

June 2004 121

28008020 SEL_INVALID_BLK_ID Reason: The block ID is not correct (internal error). Measure: Report the error log of this entry to Service.

28008021 SEL_INVALID_DEV_ID Reason: The device ID is not correct (internal error). Measure: Report the error log of this entry to Service.

28008023 SEL_INVALID_BLK_LEN Reason: The length specification is not correct (internal error). Measure: Report the error log of this entry to Service.

28008025 SEL_TASK_NOT_ENDED Reason: A second job was issued without waiting for the response from the first job (internal error). Measure: Report the error log of this entry to Service.

28008031 SEL_UNKNOWN_REQUEST Reason: A command specification which is not known to the special electronics was sent from the SEL device handler to the special electronics (internal error). Measure: Report the error log of this entry to Service.

28008032 SEL_INCORRECT_FORMAT Reason: A command with incorrect length specifications was sent from device handler SEL to the special electronics (internal error). Measure: Report the error log of this entry to Service.

Page 130: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

122 June 2004

28008033 SEL_ILLEGAL_PARAMETER Reason: A transfer buffer with illegal parameters was transferred from the application to the SEL device handler. Application: Check the parameters transferred to the SEL device handler.

28008034 SEL_NO_PROC_REQUEST Reason: The device specified in the parameter block is not configured at the moment in the special electronics. An attempt was made to switch off the monitor with the "CscSelSwMonitor" command, although the monitor switch on the special electronics is set to continuous operation (switch set to the right). Application: Check the setup configuration with the "CscSelSetConfig" command. If this configuration is correct, check the command which caused this error. Measure: Check whether the monitor switch on the special electronics should be set to continuous operation. If not, set the switch to the left.

28008036 SEL_ERROR_RAM Reason: Hardware error. Measure: Check the hardware.

28008037 SEL_EPROM_ERROR Reason: An internal hardware error has been found in the self-test of the special electronics. Measure: Check the hardware.

28008038 SEL_EEPROM_ERROR Reason: While executing a command, the special electronics found an error while it was writing to the internal EE-PROM. Measure: Check the hardware (EE-PROM).

Page 131: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

June 2004 123

28008040 SEL_ILLEGAL_LED_PARA Reason: A transfer buffer with illegal parameters was transferred from the application to the SEL device handler for switching the LEDs. Application: Check the parameters transferred to the SEL device handler.

28008041 SEL_WRONG_KEY_PARITY Reason: One of the DES keys loaded into the SEL or one of the keys in the EE-PROM (TK) has a wrong parity. Application: Check the DES keys transferred to the SEL device handler and/or reload the TK. Measure: Check the hardware.

28008042 SEL_ILLEGAL_SEQUENCE Reason: One of the keyboard commands was sent in the wrong context. Application: Check the sequence of the keyboard commands when initiating encryption.

2800A100 SEV4_ERR_NO_CMD_RESPONSE Reason: No command response received. The SEV4 firmware did not respond to a "SetPort" command in the desired time. Application: Try to repeat the command. Measure: Check the SEV4-hardware.

Page 132: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

124 June 2004

2800A101 SEV4_ERR_STILL_BUSY Reason: The SEV4 firmware did not respond to a "SetPort" command in the desired time. The last received firmware status is DEVICE_BUSY. Application: Try to repeat the command. Measure: Check the SEV4-hardware.

2800A102 SEV4_ERR_COMMAND_NOT_VALID Reason: An invalid command was sent from device handler SEV4 to the special electronics (internal error). Measure: SW-Error. Report the error log of this entry to Service.

2800A103 SEV4_ERR_COMMAND_PARA_NOT_VALID Reason: A command with incorrect parameter was sent from device handler SEV4 to the special electronics (internal error). Measure: SW-Error. Report the error log of this entry to Service.

2800A104 SEV4_ERR_SELF_TEST Reason: Firmware error. An error detected during the internal SEV4 self-test. Measure: Check the SEV4-hardware.

2800A105 SEV4_ERR_WRITE_FLASH Reason: While executing a command it was not possible to write into the internal FLASH-PROM (internal firmware error). Measure: Check the SEV4-hardware.

Page 133: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

June 2004 125

2800A106 SEV4_ERR_LOAD_SECURITY Reason: One of the DES keys loaded into the SEV4 or one of the keys in the EE-PROM (TK) has a wrong parity. Application: Check the DES keys transferred to the SEV4 device handler and/or reload the TK. Measure: Check the hardware.

2800A107 SEV4_ERR_NO_TRANSPORT_KEY_LOADED Reason: The transport key has not been loaded but the application tried to use one of the key security functions. Application: Check the DES keys transferred to the SEV4 device handler and/or reload the TK. Measure: Check the hardware.

StWarn:

20007FFE SEL_WARN_RESYNC Reason: The communication to the SEL has been resynchronized after a communication failure. In some cases one or mor keycodes may got be lost.

28007FFF SEL_WARN_RESTART Reason: The Special Electronics firmware has performed a [re-]start - after power failure or time-out of a delayed reboot (watchdog) - after a firmware loading (loadable firmware from version 0600 on) Measure: Ignore after normal system boot or firmware loading. Check the hardware. Inform Customer Service if warning occurs again.

Page 134: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Special electronics (SEL / SEV4)

126 June 2004

2800AFFF SEV4_WARN_RESTART Reason: The SEV4 firmware has performed a [re-]start - after power failure or time-out of a delayed reboot (watchdog) - after a firmware loading (loadable firmware from version 0600 on) Measure: Ignore after normal system boot or firmware loading. Check the hardware. Inform Customer Service if warning occurs again.

Page 135: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 127

Softkey/PINpad (PIN) StClass:

STCLASS_OK No error STCLASS_ERROR_PIN Error of the CSCWPIN.DLL

StCode:

20004800 PIN_FATAL_TIMEOUT Reason: A fatal time-out has occurred and the PIN threads have terminated. Application: Restart the threads by processing a CscPinClose()/CscPinOpen() sequence.

20008001 PIN_ERROR_INIT_DATA Reason: The connected PINpad is not supported by the PIN device handler or it returns faulty data. This error message is also generated when PIN keys are scanned via the special electronics and the line to the special electronics is not encrypted, but the special electronics already work in the encrypted mode. Measure: Use or replace with a valid PINpad and/or check PINpad line. If the PIN keys are scanned via the special electronics, it is sufficient to turn the special electronics off and then on again.

20008002 PIN_ERROR_NO_FUNC Reason: There was no "CscPinRead" called that could be cancelled with the "CscPinCancel" command, or the "CscPinRead" command is already finished. Application: Check the sequence and synchronization of the commands.

Page 136: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Softkey/PINpad (PIN)

128 June 2004

20008003 PIN_ERROR_UNKNOWN Reason: Internal DLL error. Measure: Report the error log of this entry to Service.

20008004 PIN_ERROR_PINPAD_TYP Reason: The connected PINpad is not supported, because it does not allow any encoding. Measure: Use/replace a valid PINpad and/or check the PINpad line.

20008005 PIN_ERROR_PINPAD_LINE Reason: It is not possible to encode the PINpad line after synchronization. Measure: Check the PINpad and PINpad line and replace if necessary.

20008006 PIN_ERROR_LOAD_TK Reason: The transport key cannot be loaded into the PINpad with the "CscPinPadInit" command. Measure: Check the PINpad and PINpad line and replace if necessary.

20008007 PIN_ERROR_LOAD_LK Reason: The line key cannot be loaded into the PINpad. Measure: Check the PINpad and PINpad line and replace if necessary.

20008008 PIN_ERROR_LOAD_IV Reason: Initial vector cannot be read from the PINpad. Measure: Check the PINpad and PINpad line and replace if necessary.

Page 137: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Softkey/PINpad (PIN)

June 2004 129

20008009 PIN_ERROR_NO_TK Reason: The connected PINpad has no transport key or the PINpad cannot store the transport key. Measure: Load the PINpad transport key in the PINpad after consultation with the security officer.

2000800A INVALID_KEY_FILE_LEN Reason: The PIN keyboard file has not the appropriate number of entries for the PINpad keys. Measure: Check PIN keyboard file and change it if required.

2000800C INVALID_KEY_FILE_EXT Reason: The specified PIN keyboard file in the Registry/CSC.INI has the wrong file extension (*.PKF). Measure: Change the PIN keyboard file extension.

2000800D KEY_FILE_OPEN_FAILED Reason: Error when opening the PIN keyboard file. Measure: Check whether the PIN keyboard file can be opened.

2000800E PIN_INVALID_KEY_CODE Reason: A keyboard code does not consist of 2 ASCII characters and/or a keyboard code does not result in a hexadecimal character (example ASCII 33 41 --> hexadecimal = 0x03a). Measure: Check the keyboard codes and change them if required.

2000800F PIN_INVALID_DECRYPTION_TYPE Reason: The specified decryption type in Registry/CSC.INI is not "EDS", "EDM", "EPP", "EPPSK" or "OFF". Measure: Check the type of encryption, change it if required.

Page 138: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Softkey/PINpad (PIN)

130 June 2004

20008010 PIN_CODE_ELEMENT_MISSING Reason: A table of the 10 numeric keyboard codes is required for EDM decryption. No 10 numeric keyboard codes could be found in the PIN keyboard file. Application: Check the PIN keyboard file and change it if required.

20008011 PIN_CODE_INVALID_OFFSET Reason: The offsets of the keyboard codes for CANCEL key, ESCAPE key and execution keys 1 + 2 are required with EDM decryption. One or more offsets do not point to a keyboard code. Application: Check the offsets and change them if required.

20008012 PIN_CANNOT_ACCESS_KEY_FILE Reason: The keyboard file cannot be accessed. Application: Check the filesystem and the access rights of the keyboard file.

20008013 PIN_THREAD_DIED Reason: The process that owned the pin thread terminated. Application: Close the DH and open it again to start a new pin thread. If an open is impossible, reboot the system.

20008016 PIN_INVALID_PINPAD_HARDWARE Reason: The specified hardware type in Registry/CSC.INI is not "PINPAD_SEL", "PINPAD_CIT", "PINPAD" or "NONE". Measure: Check the type of hardware, change it if required.

20008017 PIN_INVALID_PINPAD_BEEPER Reason: The specified value in Registry/CSC.INI is not "ON" or "OFF". Measure: Check the value, change it if required.

Page 139: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Softkey/PINpad (PIN)

June 2004 131

StWarn:

20007FFF PIN_WARN_GHOSTCODE Reason: The firmware reported a nonexistant keyboard code. If the communication line to the keyboard is encrypted the encryption will be reinitialized. One or more keyboard codes may got lost.

8001 NEW_LKEY Reason: The PINpad DLL has a new line key. Measure: Check the PINpad and the line if the problem recurs.

8002 NEW_SYNC Reason: The PINpad DLL has a new initial vector. Measure: Check the PINpad and the line if the problem recurs.

Page 140: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

132 June 2004

Page 141: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 133

Operator Panel (OPL) StClass:

STCLASS_OK No error STCLASS_ERROR_OPL Error of the CSCWOPL.DLL

StCode:

2000FA02 OPL_INIT_ERROR Reason: The logical communication with the operator panel could not be established. Measure: Check the operator panel and the V.24 line.

2000FA03 OPL_INITRUN Reason: The setup program is running on the operator panel at the moment, therefore it cannot accept commands yet. Application: Call this command again after a short wait time.

2000FA04 OPL_MAXBUFFER_EXCEEDED Reason: The operator panel requests more characters than can be buffered internally by the device handler. Application: Request less characters with job "CscOplReadCharStr".

2000FA05 OPL_INVALID_PARAMETER Reason: An invalid parameter has been specified when calling a function from the OPL device handler. Application: Check all parameters of the function which caused this error.

Page 142: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

134 June 2004

2000FA06 OPL_INVALID_PSZREPLACE Reason: The memory location, to which the pointer "pszReplace" of the type CSCOPLREADDATA points, cannot be accessed. Application: Check the contents of the structure CSCOPLREADDATA when calling the function "CscOplReadChar" or "CscOplReadCharStr".

2000FA07 OPL_INVALID_MODE Reason: The function call is not allowed due to current mode of the OPL device handler. Application: Text mode: To display a graphic the graphic mode has to be activated first. Graphic mode: Calls of functions modifying the screen content are not possible.

2000FA08 OPL_RUNNING_SCRIPT Reason: The function call is not possible because currently a script is being executed. Application: Wait for the user action terminating the execution of the script file.

2000FA0A OPL_NO_CURSOR_POS_SAVED Reason: The "CscOplRestoreCurPos" function was called before the cursor was saved with the "CscOplSaveCurPos" function. Application: Save the cursor position beforehand with the "CscOplSaveCurPos" function.

2000FA0B OPL_INVALID_RESPONSE Reason: The received V.24 data were not in the expected format. Measure: Check the hardware.

2000FA30 OPL_GRAPHIC_FILE_OPEN Reason: Error opening the graphic file. Measure: Check the graphic file.

Page 143: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

June 2004 135

2000FA31 OPL_GRAPHIC_FILE_READ Reason: Error reading the graphic file. Measure: Check the graphic file.

2000FA32 OPL_GRAPHIC_FILE_SETPOS Reason: Error setting the position within the graphic file. Measure: Check the graphic file.

2000FA33 OPL_GRAPHIC_FILE_CLOSE Reason: Error closing the graphic file. Measure: Check the graphic file.

2000FA34 OPL_GRAPHIC_INVALID_TYPE Reason: The format specified within the graphic file is not supported. Measure: Check the graphic file.

2000FA35 OPL_GRAPHIC_INVALID_RESOLUTION Reason: The resolution specified within the graphic file is not supported. Measure: Check the graphic file.

2000FA36 OPL_GRAPHIC_INVALID_COLOR Reason: The number of colours specified within the graphic file is not supported. Measure: Check the graphic file.

Page 144: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

136 June 2004

2000FA37 OPL_GRAPHIC_INVALID_COMPRESSION Reason: The data compression specified within the graphic file is not supported. Measure: Check the graphic file.

2000FA38 OPL_GRAPHIC_INVALID_SIZE Reason: The graphic file has got an invalid size. Measure: Check the graphic file.

2000FA39 OPL_GRAPHIC_PATH_TOO_LONG Reason: The fully-qualified filename is too long. Measure: Check the length of the filename; possibly in consideration of CSCROOT.

2000FA40 OPL_SCRIPT_FILE_OPEN Reason: Error opening the script file. Measure: Check the script file.

2000FA41 OPL_SCRIPT_FILE_READ Reason: Error reading the script file. Measure: Check the script file.

2000FA42 OPL_SCRIPT_FILE_CLOSE Reason: Error closing the script file. Measure: Check the script file.

Page 145: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

June 2004 137

2000FA43 OPL_SCRIPT_LINE_TOO_LONG Reason: The script file contains a line that is too long. Measure: Check the script file.

2000FA44 OPL_SCRIPT_TOO_MANY_COMMANDS Reason: There are too many commands within the script file. Measure: Check the script file.

2000FA45 OPL_SCRIPT_INVALID_COMMAND Reason: Invalid command in script file. Measure: Check the script file.

2000FA46 OPL_SCRIPT_INVALID_SYNTAX Reason: Invalid command syntax in script file. Measure: Check the script file.

2000FA47 OPL_SCRIPT_INVALID_PARA Reason: Invalid parameter in script file. Measure: Check the script file.

2000FA48 OPL_SCRIPT_MISSING_PARA Reason: Command parameter missing in script file. Measure: Check the script file.

Page 146: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

138 June 2004

2000FA49 OPL_SCRIPT_MISSING_REPEAT Reason: Command REPEAT missing in script file (ENDREP without REPEAT). Measure: Check the script file.

2000FA4A OPL_SCRIPT_MISSING_ENDREP Reason: Command ENDREP missing in script file (REPEAT without ENDREP). Measure: Check the script file.

2000FA4B OPL_SCRIPT_NESTED_LOOP Reason: Nested loop not allowed in script file. Measure: Check the script file.

2000FA4C OPL_SCRIPT_EMPTY_LOOP Reason: Empty loop not allowed in script file. Measure: Check the script file.

2800FA11 OPL_PARITY_ERROR Reason: The operator panel detected a parity error during data transmission. Application: Repeat job Measure: Check V.24 connection. Inform Customer Service if error occurs again.

Page 147: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

June 2004 139

2800FA12 OPL_USER_CHARSIZE_NOT_DEFINED Reason: The character size defined by the user is not defined. Application: The application uses a character size which is not supported by the connected operator panel. Measure: Check that the correct operator panel is connected.

2800FA13 OPL_CODETABLE_RAM_FULL Reason: The character set RAM is filled or the function is not supported. Measure: Check the hardware.

2800FA14 OPL_CHAR_DEFDAT_NOT_CORRECT Reason: The character definition data are not correct. Application: Check application program

2800FA15 OPL_HARDWARE_FAILURE Reason: Hardware faulty. Measure: Check the hardware

2800FA16 OPL_ESC_SEQUENCE_UNKNOWN Reason: A job (ESC sequence) sent to the operator panel is not known. Application: Check the parameters of job CscOplWrtCharStr. Measure: Check the hardware.

Page 148: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Operator Panel (OPL)

140 June 2004

2800FA17 OPL_JOB_CANCELED Reason: Operator panel aborted the job internally. Measure: Check the hardware.

2800FA20 OPL_KEYBOARD_ERROR Reason: Keyboard is defect or the key of High end OPL is in horizontal position. Measure: Check the hardware.

Page 149: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 141

CIT Control Panel (CIT) StClass:

STCLASS_OK No error STCLASS_ERROR_CIT Error of the CSCWCIT.DLL

StCode:

20009000 CIT_INVALID_RESPONSE Reason: The data received from the CIT hardware was not of the expected format. Measure: Check hardware.

20009001 CIT_INVALD_DATA Reason: The application gave invalid data to the DH. Application: Check the application program.

20009002 CIT_BUFFER_OVERFLOW Reason: The internal buffer for messages from the CIT hardware is full. Measure: Report this error log to service.

20009003 CIT_NO_CURSOR_POS_SAVED Reason: The function CscCitRestoreCurPos was called before the function CscCitSaveCurPos. Application: Call CscCitSaveCurPos before CscCitRestoreCurPos.

Page 150: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CIT Control Panel (CIT)

142 June 2004

20009004 CIT_NO_RESPONSE Reason: The CIT hardware did not send data when this was expected. Measure: Check hardware.

20009005 CIT_WRONG_INIT_IOPORT Reason: Wrong value for IOPORT in Registry/CSC.INI with [CSCCIT]. Measure: Check the parameter IOPORT in Registry/CSC.INI.

20009006 CIT_CSCNPORT_DRIVER_NOT_FOUND Reason: I/O card driver (CSCNPORT.SYS) not found. Measure: Check configuration.

28009103 CIT_JOB_CANCELED Reason: This is an internal error of the CIT hardware. The command could not be decoded by the firmware. Measure: Check hardware.

Page 151: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 143

Encryption/Decryption Software (EDS) StClass:

STCLASS_OK No error STCLASS_ERROR_EDS Error of the CSCWEDS.DLL

StCode:

20008001 EDS_ERROR_NO_TK Reason: No transport key is loaded or the key file CSCEDS.KEY is not available. Application: Load the transport key again. Measure: Check whether the key file is in the <CSCROOT>\BIN directory.

20008002 EDS_ERROR_TK_PARITY Reason: An invalid transport key is available (parity error) or the transport key loaded with the "CscEdsLoadTK" command has a parity error. Application: Load the transport key again.

20008003 EDS_ERROR_NO_CBC_KEY Reason: No CBC key is loaded or the CSCEDS.KEY key file is not available. Application: Load the CBC key again. Measure: Check whether the key file is in the <CSCROOT>\BIN directory.

Page 152: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption Software (EDS)

144 June 2004

20008004 EDS_ERROR_CBC_PARITY Reason: An invalid CBC key is available (parity error) or the CBC key loaded with the "CscEdsLoadCBCKey" command has a parity error. Application: Load the CBC key again.

20008005 EDS_ERROR_NO_IV Reason: No initial vector loaded or CSCEDS.KEY key file not available. Application: Load initial vector again. Measure: Check whether the key file is in the <CSCROOT>\BIN directory.

20008007 EDS_ERROR_NO_ECB_KEY Reason: No ECB key is loaded or the CSCEDS.KEY key file is not available. Application: Load the ECB key again. Measure: Check whether the key file is in the <CSCROOT>\BIN directory.

20008008 EDS_ERROR_ECB_PARITY Reason: An invalid ECB key is available (parity error) or the ECB key loaded with the "CscEdsLoadECBKey" command has a parity error. Application: Load the ECB key again.

2000800A EDS_ERROR_ZERO_BUFFER_LENGTH Reason: The length specified in the parameter block for the input buffer "CscDhlPara.InLen" or for the output buffer "CscDhlPara.OutLen" is zero. Application: Check application program.

Page 153: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption Software (EDS)

June 2004 145

2000800B EDS_ERROR_INVALID_BUFFER_LENGTH Reason: The length specified in the parameter block for the input buffer "CscDhlPara.InLen" or for the output buffer "CscDhlPara.OutLen" cannot be divided by eight. Application: Check application program.

2000800C EDS_ERROR_KEY_FILE Reason: Error while accessing the CSCEDS.KEY key file. Application: Repeat the last command. If the error recurs, the application should be terminated. Measure: Check whether the CSCEDS.KEY key file can be read or written. Check the file attributes of the key file.

2000800D EDS_ERROR_NO_RESTOREFILE Reason: Error while accessing the CSCEDS_REST.KEY key file. Application: Repeat the last command. If the error recurs, the application should be terminated. Measure: Check whether the CSCEDS_REST.KEY key file can be read or written. Check the file attributes of the key file.

2000800E EDS_ERROR_RESTORE_FILE Reason: Error while accessing the CSCEDS_REST.KEY key file. Application: Repeat the last command. If the error recurs, the application should be terminated. Measure: Check whether the CSCEDS_REST.KEY key file can be read or written. Check the file attributes of the key file.

Page 154: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

146 June 2004

Page 155: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 147

Encryption/Decryption module (EDM) StClass:

STCLASS_OK No error STCLASS_ERROR_EDM Error of the CSCWEDM.DLL

StCode:

20008101 EDM_VEM_NOT_INIT Reason: EDM not initialized. Application: Initialize EDM Measure: If the message recurs, replace or check the EDM.

20008102 EDM_INVALID_BLK_LEN Reason: The length specified in the parameter block for the "CscDhlPara.InLen" input buffer or for the "CscDhlPara.OutLen" output buffer cannot be divided by eight. Application: Check the application program.

20008103 EDM_INVALID_CMD Reason: The DLL command specification is invalid. Application: Check the command in the application program.

Page 156: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

148 June 2004

20008104 EDM_INVALID_PARA Reason: The command parameters are incorrect. Application: Check the command parameters in the application program.

20008105 EDM_INVALID_KEY_NO Reason: Invalid key number. Application: Check key number in application program.

20008107 EDM_INVALID_FRM_DATA Reason: Error during data transmission. Application: Issue job again. Check application program, if necessary. Measure: Check firmware version.

2000810B EDM_INVALID_IV_LEN Reason: Initialize vector has wrong length (not eight). Application: Check application program.

2000810C EDM_NO_IV_SPACE Reason: No free space in IV array (internal error) Application: More than 12 encryption/decryption operations are performed. Check application program.

Page 157: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 149

2000810E EDM_MEMORY_ALLOC_ERROR Reason: System could not provide dynamic memory. Application: Reboot system. Measure: Check memory configuration of PC hardware and disk space.

20008111 EDM_PIN_INVALID_MAX_LEN Reason: Wrong maximum PIN length with job "EdmStartPin". Application: Check application program.

20008112 EDM_PIN_INVALID_MIN_LEN Reason: Wrong minimum PIN length with job "EdmStartPin". Application: Check application program.

20008113 EDM_PIN_INVALID_ZERO_CMD Reason: An invalid field for leading zeros is in the PIN structure with job "EdmStartPin". Application: Check application program.

20008114 EDM_PIN_INVALID_QUIT_CMD Reason: An invalid field for "acknowledge key" is in the PIN structure with job "EdmStartPin". Application: Check application program.

20008115 EDM_PIN_INVALID_MODE Reason: Invalid mode in the PIN structure. Application: Check application program.

Page 158: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

150 June 2004

20008116 EDM_PIN_INVALID_POS Reason: Wrong PIN position in PIN field (validation data). Application: Check application program.

20008118 EDM_PIN_INVALID_TESTMODE Reason: Wrong structure entry in field "TestMode". Application: Check application program.

20008119 EDM_PIN_INVALID_PINLEN Reason: Invalid number of PIN digits. Application: Check application program.

2000811A EDM_DLL_INVALID_API Reason: This API is not supported by the device handler. Application: Check application program. Measure: Check DLL release. Check firmware version.

2000811B EDM_DLL_PROC_NOT_FOUND Reason: The API could not be loaded. Application: Check application program. Measure: Check DLL release. Check system software for completeness.

Page 159: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 151

2000811C EDM_DLL_ACCESS_DENIED Reason: This function cannot be accessed with the firmware used in the ENCRYPTION/DECRYPTION MODULE. Application: Check application program Measure: Check DLL release. Check firmware version.

2000811E EDM_INVALID_DATA_ACCESS Reason: Cannot access full length of data area in a structure. Application: Check application program

2000811F EDM_INVALID_IV_MODE Reason: Invalid encryption mode specified for key reset. Application: Check application program

20008120 EDM_PROTOCOL_TIMEOUT Reason: The total protocol monitoring time has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008121 EDM_MAX_RX_RETRIES Reason: The maximum number of receive repeats has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 160: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

152 June 2004

20008122 EDM_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid (only ACK and NAK are valid). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008123 EDM_PROTOCOL_ERROR Reason: Common protocol error in EPP response data. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware if necessary.

20008124 EDM_INVALID_PAIR_OF_KGK Reason: Key Generating Keys in REGISTRY/CSC.INI are not correct. Application: Correct Keys. Measure: Check the REGISTRY or CSC.INI.

20008125 EDM_INVALID_KGK_VALUE Reason: Invalid character in KGK Keyset in REGISTRY/CSC.INI. Application: Correct Keys. Measure: Check the REGISTRY or CSC.INI.

Page 161: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 153

20008126 EDM_ERROR_MK_CHECK Reason: Error when encrypting a Masterkey. Application: Enter or load correct Masterkey. Measure: Check the REGISTRY or CSC.INI.

20008127 EDM_INVALID_MAC Reason: The check of the CFB-MAC via the EF_INFO data field of the chip card is negative. Faulty or wrong chip card. Application: The sequence may have to be started once more.

20008128 EDM_ALREADY_IN_USE Reason: The EPP is in use. This command cannot be processed in this state. Application: Close all processes using the EPP.

20008129 EDM_MALLOC_ERROR Reason: There is not enough memory. Application: Close all processes using the EPP.

2000812A EDM_KEYTABLE_FULL Reason: The key table is full. Application: Delete the keys that are not required.

2000812B EDM_INVALID_KEYNAME Reason: The key name contains wrong characters (value <0x20 or >0x7F). Application: Use a correct key name.

Page 162: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

154 June 2004

2000812C EDM_IMPORT_WRONG_TYPE Reason: It is not allowed to import an 8 byte DES key as an importer key. Application: Use a 16 byte key.

2000812D EDM_BUFFER_OVERFLOW Reason: Over the PIN device (keyborad) more than 15 indications were entered within a certain time interval. Application: System overload. The input characters could not be evaluated in time by the ATM.

20008202 EDM_APSS_INVALID_KEY_TYPE Reason: The key number or the key type is wrong. Application: Use the correct key or key type.

20008300 EDM_FRMLD_IN_PROGRESS Reason: The firmware load function is running. Application: Wait for the end of the load function.

20008301 EDM_FRMLD_NBR Reason: No block received. Measure: Check the hardware.

20008302 EDM_FRMLD_RNR Reason: Receiver not ready. Measure: Check the hardware.

Page 163: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 155

20008303 EDM_FRMLD_SNR Reason: Sender not ready. Measure: Check the hardware.

20008304 EDM_FRMLD_DIST Reason: Line disturbed. Measure: Check the hardware.

20008305 EDM_FRMLD_FORMAT Reason: The command block has a wrong format. Measure: Report the error log of this entry to Service.

20008306 EDM_FRMLD_LOADER Reason: Unknown loader error. Measure: Report the error log of this entry to Service.

20008307 EDM_FRMLD_CMDSEQ Reason: Illegal command sequence. Measure: Report the error log of this entry to Service.

28008000 EDM_FRM_UNDEF_ERROR Reason: An undefined internal error has occurred in the firmware. Measure: Check the hardware.

Page 164: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

156 June 2004

28008001 EDM_FRM_CMD_NOT_EXEC Reason: The firmware cannot execute the command. Measure: Command number, check EDM status, enter PIN ready.

28008002 EDM_FRM_INVALID_KEY Reason: Key address (key number) not allowed (internal error). Application: Correct key number. Measure: Check EDM firmware release.

28008003 EDM_FRM_RAM_ERROR Reason: EDM RAM error (internal hardware error). Measure: Replace EDM/EPP

28008004 EDM_FRM_PARITY_ERROR Reason: Parity error in key. Measure: Check key address and load again, if necessary. This is a warning following a "load key" command. Wrong parity of loaded key. Parity was corrected by EDM/EPP, and key was loaded to specified address.

28008005 EDM_FRM_EPROM_ERROR Reason: Internal hardware E-PROM error. Measure: Replace EDM/EPP

Page 165: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 157

28008006 EDM_FRM_EEPROM_ERROR Reason: Internal hardware EE-PROM error. Measure: Replace EDM/EPP

28008007 EDM_FRM_CMD_NOT_EXIST Reason: The EDM command does not exist (internal error). Measure: Check EDM firmware release.

28008008 EDM_FRM_KEY_RAM_ERROR Reason: The EDM key RAM is defective (internal error). Measure: Check EDM and replace if necessary.

28008009 EDM_FRM_LENGTH_ERROR Reason: The transferred data length is invalid (internal error). Measure: Check EDM firmware release.

2800800A EDM_FRM_BLOCK_IDENT Reason: An invalid block ID is in the V.24 protocol (internal error). Measure: Check EDM firmware release.

2800800B EDM_FRM_DEVICE_ID Reason: The device ID is invalid (internal error). Measure: Check EDM firmware release.

Page 166: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

158 June 2004

2800800C EDM_FRM_COMMAND_ACTIVE Reason: A command has already been transferred for processing to the EDM firmware. Application: Retry job after a certain time.

2800800D EDM_FRM_DATA_LENGTH_ERR Reason: Command length and data length invalid (internal error). Measure: Check EDM firmware release.

2800800E EDM_FRM_OUTPUT_PARA Reason: Output parameters not defined (internal error). Measure: Check EDM firmware release.

2800800F EDM_FRM_UNDEF_DATA Reason: Data contains invalid ASCII characters (internal error). Measure: Check EDM firmware release.

28008010 EDM_FRM_CHECKSUM_ERROR Reason: Wrong sequence of commands. The EDM status is not "READY". Application: Encryption must be preceded by a positive checksum test. Check application program.

28008011 EDM_FRM_ID_ERROR Reason: Wrong ID. The entered (encoded) ID is not correct. Application: Change application program. Measure: Use correct ID (transport-encoded)

Page 167: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 159

28008040 EDM_FRM_TRANSAC_N_ACTIVE Reason: No transaction active, command cannot be executed. Application: Start transaction.

28008041 EDM_FRM_INVALID_PINLEN Reason: No or not enough PIN numbers entered. Application: Repeat command.

28008045 EDM_FRM_KEY_EXISTS Reason: The key with this name exists already in the EPP. Application: Delete the key with the export command or use a different key name.

28008046 EDM_FRM_KEY_NOT_FOUND Reason: The key with this name is not loaded in the EPP. Application: Use the correct key.

28008047 EDM_FRM_KEY_NOT_ALLOWED Reason: The use of this key for this function is not allowed. Application: Use the correct key.

28008048 EDM_FRM_NO_RSA_PROCESSOR Reason: There is no RSA processor in the EPP. Measure: Check the hardware and change it if necessary.

Page 168: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

160 June 2004

28008049 EDM_FRM_WRONG_RSA_KEY_LEN Reason: The modulus length of the RSA key is not ok. Application: Use the correct length.

28008050 EDM_FRM_SP_EPROM_ERROR Reason: Key-splitting E-PROM not connected or wrong. Measure: Check EDM. Install PROM.

28008051 EDM_FRM_SP_CHECK_ERROR Reason: Checksum of key-splitting E-PROM is wrong. Measure: Check hardware and E-PROM contents.

28008052 EDM_FRM_SP_PARITY_ERROR Reason: Parity error in key of the key-splitting E-PROM. Application: Load correct key. Measure: Check hardware and E-PROM contents.

28008053 EDM_FRM_SP_TABLE_ERROR Reason: Invalid table character in key-splitting E-PROM. Measure: Check hardware and E-PROM contents.

28008060 EDM_FRM_X_ERROR Reason: V.24 connection PC to EDM was/is interrupted. The working keys are deleted. Measure: Check V.24 line, check hardware. Re-initialize device handler and load key.

Page 169: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

June 2004 161

28008061 EDM_FRM_BATTERY_EMPTY Reason: The minimum battery current flows out of the internal control window of the connected EPP. Measure: Have the hardware checked by service.

28008062 EDM_FRM_KEY_ENTRY_ERROR Reason: The EPP detects an error when entering a key by use of the EPPs key pad. Measure: Repeat carefully the complete key entry procedure. If the error occurs again, there might be a wrong key set. Initialize the EPP, enter a new transport key. Have the hardware checked by service.

28008063 EDM_FRM_APSS_KEY_ERROR Reason: The EPP detects an error when loading a key in APSS mode. Application: Use the correct key.

28008064 EDM_FRM_WRONG_KEK Reason: The EPP detects an error when loading a key. Application: Use the correct importer key or load the importer key.

28008065 EDM_FRM_SCOP_AUTHENTICATE Reason: The EPP detects an error when authenticating the SCOP chip card. Measure: Check if the chipcard in the SCOP controller is wrong.

28008066 EDM_FRM_SCOP_PARA_TYPE Reason: The EPP detects an error when loading the SCOP parameters. One Type is wrong. Application: Load the correct Type.

Page 170: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Encryption/Decryption module (EDM)

162 June 2004

28008067 EDM_FRM_SCOP_PARA Reason: The EPP detects an error when loading the SCOP parameters. One sequence is wrong. Application: Load the correct sequence.

28008068 EDM_FRM_SCOP_PARA_LENGTH Reason: The EPP detects an error when loading the SCOP parameters. The length is wrong. Application: Load the correct length.

Page 171: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 163

Secure Cash-Out (SCO) StClass:

STCLASS_OK No error STCLASS_ERROR_SCO Error of the CSCWSCO.DLL

StCode:

0008000 SCO_CHIP_CONTROLLER_ERROR Reason: SCO chip card controller is not OK. Measure: If the message recurs, replace or check the chip card controller.

20008001 SCO_OFFLINE_CHIP_MISSING Reason: The "offline" chip card was not inserted or has no proper contact. The registry parameter OFFLINE is set to YES. Measure: Check if the "offline" chip card was inserted. If the "offline" chip card was inserted, clean the chip card connectors.

20008002 SCO_OFFLINE_CHIP_APL_ERROR Reason: The "offline" chip card is not OK or wrong. Measure: Change the "offline" chip card.

20008003 SCO_ONLINE_CHIP_APL_ERROR Reason: The "online" chip card is not OK or wrong. Measure: Change the "online" chip card.

Page 172: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Secure Cash-Out (SCO)

164 June 2004

20008004 SCO_NO_MSG_PARAMETER Reason: The parameter MESSAGE_PARAMETER in the registry is missing. Application: Check the registry. Insert the parameter MESSAGE_PARAMETER.

20008005 SCO_WRONG_MSG_PARAMETER Reason: The parameter MESSAGE_PARAMETER in the registry is wrong. Application: Check the registry. Insert the correct sentence for parameter MESSAGE_PARAMETER.

20008006 SCO_CONT_UNDEF_ERROR Reason: The error number received from the chip card controller is unknown. Measure: Change the chip card controller.

28008010 SCO_CHIP_MISSING Reason: The "online" chip card was not inserted. Measure: Check if the "online" chip card was inserted. If the chip card was inserted, clean the chip card connectors.

28008011 SCO_CHIP_NOT_SELECTED Reason: The chip card was not selected. Application error. Application: Check the application program.

28008012 SCO_P1P2_ERROR Reason: The parameter P1 or P2 is wrong. Application error. Application: Check the application program.

Page 173: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Secure Cash-Out (SCO)

June 2004 165

28008013 SCO_APL_NO_INIT Reason: The chip card controller was not initialized. Application: Check the application program.

28008014 SCO_CHIP_AUTH_ERROR Reason: The chip card is wrong. Measure: Insert the correct chip card.

28008015 SCO_CHIP_TIMEOUT_ERROR Reason: The maximum open time for the application on the chip card is elapsed. (Security feature) Application: The open time can be changed with the registry parameter CERTIFICATE_TIMEOUT.

28008016 SCO_CHIP_EFDAT_ERROR Reason: The chip card is wrong or defective. Measure: Insert the correct chip card.

28008017 SCO_CHIP_CHALLENGE_ERROR Reason: The chip card is wrong or defective. Measure: Insert the correct chip card.

28008018 SCO_CHIP_CONT_RAM_ERROR Reason: The RAM on the chip card controller is defect. Measure: Change the chip card controller.

Page 174: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Secure Cash-Out (SCO)

166 June 2004

28008019 SCO_CHIP_CONT_CODE_ERROR Reason: The program on the chip card controller is defective. Measure: Change the chip card controller.

Page 175: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 167

RSA module StClass:

STCLASS_OK No error STCLASS_ERROR_RSA Error of the CSCWRSA.DLL

StCode:

20008000 RSA_MEMORY_ALLOC_ERROR Reason: Not enough memory in the PC. Measure: Put more memory into the PC.

20008002 RSA_BUFFER_TO_SMALL Reason: The specified output buffer is too short.. Application: To observe the required buffer length.

20008003 RSA_UNDEF_ERROR Reason: The error number reported from the EPP is unknown. Measure: Inform service.

20008004 RSA_EXPONENT_LEN Reason: The specified exponent is too long. Application: To observe the maximum length.

Page 176: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

RSA module

168 June 2004

20008005 RSA_MODULUS_LEN Reason: The specified modulus is to long. Application: To observe the maximum length.

20008006 RSA_NO_KEY_INFO Reason: For the specified key is no serial number stored. Application: New personalisation required.

20008007 RSA_WRONG_KEY_INFO Reason: In the file for additional.key info is an error. Application: New personalisation required.

Page 177: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 169

Remote Key Loading StClass:

STCLASS_OK No error STCLASS_ERROR_RKL Error of the CSCWRKL.DLL

StCode:

20008010 RKL_ERR_WRONG_SPEC Reason: An unknown specification was selected for the function. Application: Select only specifications that are supported by the documentation

20008011 RKL_ERR_SELECT_ADF Reason: RKL-ADF could not be selected. Application: The EPP does not yet have the firmware necessary for the RKL. Reload the suitable RKL firmware.

20008012 RKL_ERR_INTERNAL Reason: An internal error was detected during the processing of the command. Application: Internal error, inform manufacturer.

28007001 RKL_ERR_PARAMETER Reason: A command parameter is not permitted. Application: Select the correct parameter according to Spec.

Page 178: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Remote Key Loading

170 June 2004

28007002 RKL_ERR_DATA_LEN_INSUF Reason: The data length does not match the communicated data length. Application: Calculate and communicate the correct data length.

28007003 RKL_ERR_SIGN_LEN_INV Reason: The signature length does not match the key. Application: Select a signature that matches the key.

28007010 RKL_ERR_TOKEN_UNKNOWN Reason: Unknown key token. Application: Select only permitted tokens according to RKL specification.

28007011 RKL_ERR_TOKEN_ILLEGAL Reason: Illegal key token. Application: Select only tokens that are permitted according to the RKL specification.

28007020 RKL_ERR_FORMAT_ASN1 Reason: A format error in the TLV structure was found. Application: The TLV stucture must conform to the specification.

28007021 RKL_ERR_FORMAT_PKCS Reason: A PKCS format error was found. Application: Input data that corresponds to the PKCS format construct.

Page 179: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Remote Key Loading

June 2004 171

28007070 RKL_ERR_SIGN_INV Reason: Wrong MAC/signature. Application: Correctly calculate the MAC/signature.

28007071 RKL_ERR_SECURE_RND Reason: Non-matching random number generated by the ADF. Application: Program error, take suitable random number into account.

28007090 RKL_ERR_MEMORY_OVFL Reason: In sufficient memory available in the FDM. Application: Application change in order to use less memory.

28007091 RKL_ERR_KEYRAM_OVFL Reason: In sufficient memory available in the key RAM. Application: Select less key data.

280070A1 ERR_STATUS_ILLEGAL Reason: Status error. Call of the command is not permitted in the current ADF status. Application: Consult the specifications for information which commands are allowed at which moment.

280070B1 RKL_ERR_OS_INTERNAL Reason: The OS detected an error during the processing of the command. Application: Internal firmware error, inform manufacturer.

Page 180: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

172 June 2004

Page 181: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 173

CBKM module StClass:

STCLASS_OK No error STCLASS_ERROR_CBKM Error of the CSCWCBKM.DLL

StCode:

20008000 CBKM_THUMBPRINT_ERROR Reason: Key Import error, invalid thumbprint. Application: Compare thumprint with key generation thumbprint.

20008001 CBKM_INVALID_RAND Reason: Received random value differs from generated random value. Application: Check value sent to host.

20008002 CBKM_INVALID_SIG Reason: Verification of signature invalid. Application: Check public key.

20008003 CBKM_INVALID_KEYID Reason: Received KeyID differs from generated KeyID. Application: Check KeyID of generated key.

Page 182: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CBKM module

174 June 2004

20008004 CBKM_INVALID_KEYNO Reason: Received KeyNo differs from generated KeyNo. Application: Check KeyNo of generated key.

20008005 CBKM_INVALID_KEYVER Reason: Received KeyVersion differs from generated KeyVersion. Application: Check KeyVersion of generated key.

20008006 CBKM_ KEY_NOT_TRUSTED Reason: Exported key not trusted. Application: Delete Key and generate a new one.

20008007 CBKM_ INVALID_SCDNO Reason: Received SCD serial number differs from EPP serial number. Application: Check EPP serial number.

20008010 CBKM_UNEXPECTED_END Reason: CscwCbkmEnd function called within KeyManagement process. Application: Init of KeyManagement process required.

Page 183: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 175

Swiss Encryption Protocol (SEP) StClass:

STCLASS_OK No error STCLASS_ERROR_SEP Error of the CSCWSEP.DLL

StCode:

20008000 SEP_MEMORY_ALLOC_ERROR Reason: Not enough memory in the PC. Measure: Put more memory into the PC.

20008001 SEP_FRM_UNDEF_ERROR Reason: The error number reported from the EPP is unknown. Measure: Inform Service.

28008010 SEP_FRM_PPV_ERROR Reason: The PPV is wrong. Application: Check application program.

28008011 SEP_FRM_NO_PPV Reason: The PPV is not loaded. Application: Check application program.

Page 184: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Swiss Encryption Protocol (SEP)

176 June 2004

28008012 SEP_FRM_NO_PIN_BLOCK Reason: No PIN block in the PIN buffer. Application: Check application program.

28008013 SEP_FRM_NO_PIN_CHANGE Reason: The PIN change is not possible because the first PIN entry is not complete. Application: Check application program.

28008014 SEP_FRM_PIN_CHANGE_ERROR Reason: PIN 1 and PIN 2 are not equal. Application: Special application reaction.

28008015 SEP_FRM_NO_SECURITY_BLOCK Reason: No security block in the EPP. Application: Check application program.

28008016 SEP_FRM_HASH_ERROR Reason: The hash value in the message is wrong. Application: Retry command.

28008017 SEP_FRM_PVV_KEY_ERROR Reason: The key set is wrong. Application: Check application program.

Page 185: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Swiss Encryption Protocol (SEP)

June 2004 177

28008018 SEP_FRM_PVV_PIN_ERROR Reason: Wrong PIN entry. Application: Special application reaction.

28008019 SEP_FRM_NO_CARD_FUNCTION Reason: No support for this card type. Application: Special application reaction.

2800801A SEP_FRM_NO_KEY_FUNCTION Reason: This function supports only key set 02. Application: Check application program.

2800801B SEP_FRM_PVV_TP_KEY_INVALID Reason: The PVV transport key is invalid. Measure: Load the correct key.

2800801C SEP_FRM_PVV_BK_KEY_INVALID Reason: The PVV bank basic key is invalid. Measure: Load the correct key.

2800801D SEP_FRM_WRONG_MODE Reason: The PVV transport key is invalid. Measure: Load the correct key.

Page 186: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Swiss Encryption Protocol (SEP)

178 June 2004

2800801E SEP_FRM_BUFFER_FULL Reason: The data buffer is full. Application: Check application program.

2800801F SEP_FRM_WRONG_TUNPACK Reason: The TUNPACK is wrong. Application: Check application program.

28008401 SEP_FRM_FORMAT_ERR Reason: An internal command has a wrong format. Application: Check application program.

28008402 SEP_FRM_PROT_ERR Reason: Internal protocol error. Application: Retry command.

28008403 SEP_FRM_HW_LOCK Reason: The EPP is locked. The reason is an hardware error. Measure: Call service.

28008404 SEP_FRM_SECURITY_LOCK Reason: The EPP is locked. The reason is manipulation. Measure: Call service.

Page 187: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Swiss Encryption Protocol (SEP)

June 2004 179

28008405 SEP_FRM_UNKNOWN_CMD Reason: The internal command is unknown. Measure: Call service.

28008406 SEP_FRM_ADF_TO_LARGE Reason: The ADF is to large. Measure: Call service.

28008407 SEP_FRM_WRONG_STATE Reason: The function is in this state not allowed. Application: Check application program.

28008408 SEP_FRM_NO_ADF Reason: The wanted ADF is not in the EPP. Application: Load the ADF.

28008409 SEP_FRM_INTERNAL_ERR Reason: An EPP internal error occurred. Application: Retry command.

2800840C SEP_FRM_RAM_OVERFLOW Reason: The memory in the EPP is full. Measure: Call service.

Page 188: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Swiss Encryption Protocol (SEP)

180 June 2004

2800840D SEP_FRM_LOAD_LEN Reason: ADF load error. The ADF on hard disk is wrong. Measure: Call service.

2800840E SEP_FRM_CHECKSUM_ERR Reason: ADF load error. The ADF on hard disk is wrong. Measure: Call service.

2800840F SEP_FRM_ADF_LOCKED Reason: The ADF is locked. Measure: Call service.

28008413 SEP_FRM_MAC_ERR Reason: ADF load error. The MAC of the ADF on hard disk is wrong. Measure: Call service.

Page 189: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 181

Security Module SIBS StClass:

STCLASS_OK No error STCLASS_ERROR_SIBS Error of the CSCWSIBS.DLL

StCode:

28007001 SIBS_ERR_DATA_LEN_INSUF Reason: The data length of the response has not the expected length (firmware error). Measure: Report the error log of this entry to Service.

28007002 SIBS_ERR_DATA_INV Reason: The input data has not the expected range. Application: Send the data in the expected range.

28007003 SIBS_ERR_FDM_ACC Reason: Access error to the internal data file (firmware error). Measure: Report the error log of this entry to Service.

2800702D SIBS_ERR_FORMAT_HEX Reason: The input data is not in the HEX- format. Application: Deliver the input data in the correct format.

Page 190: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Security Module SIBS

182 June 2004

280070A1 SIBS_ERR_CMD_STAGE_INV Reason: This command is not allowed in the actual ADF state. Application: Bring the EPP in the correct state.

280070A2 SIBS_ERR_CACHE_MISS Reason: PIN data not available. Application: Insert PIN.

280070A3 SIBS_ERR_TEXT_LEN_INSUF Reason: The given text length has not the same length as the input text. Application: Correct the input text length.

280070A4 SIBS_ERR_PIN_BLK_TYPE_INV Reason: Unknown PIN block type. Application: Give the correct PIN block type.

280070A5 SIBS_ERR_MAC_INV Reason: MAC failure, the given MAC differs from the calculated MAC. Application: Calculate the MAC correct.

280070A6 SIBS_ERR_ACQ_BLK_FULL Reason: The key table of the EPP is full. Its not permitted to store more than six keys in the table. Application: Application specific behaviour (its possible to perform "clear database").

Page 191: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Security Module SIBS

June 2004 183

280070A7 SIBS_ERR_ACQ_KCV_INV Reason: The key check value (KVC) is not correct. Application: Calculate the key check value correct.

280070A8 SIBS_KEY_PAR_INV Reason: The key parity is not ok. Application: Calculate the key parity correct.

280070A9 SIBS_ERR_ACQ_KEY_MISS Reason: The requested key is not in the key table. Application: Insert the key in the key table.

280070AA SIBS_ERR_KEY_NAME_UNKNOWN Reason: This key name is unknown. Application: Please write the key name correct.

28008000 SIBS_CMD_OK Reason: Command successful (status message).

28008001 SIBS_FRM_UNDEF_ERROR Reason: The reported error message from the EPP is unknown. Measure: Inform Service.

Page 192: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Security Module SIBS

184 June 2004

28008002 SIBS_FRM_NO_ADF Reason: The EPP has not the correct SIBS-ADF. Application: Load the correct SIBS-ADF in the EPP.

Page 193: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 185

Online Personalization Terminals (OPT) StClass:

STCLASS_OK No error STCLASS_ERROR_OPT Error of the CSCWOPT.DLL

StCode:

20008000 OPT_MEMORY_ALLOC_ERROR Reason: Not enough memory in the PC. Measure: Put more memory into the PC.

20008001 OPT_FRM_UNDEF_ERROR Reason: The error number reported from the EPP is unknown. Measure: Inform Service.

20008003 OPT_NO_OZR Reason: The on-line timeframe was not yet transferred to the OPT-DLL. Application: Transfer the on-line timeframe.

20008004 OPT_NO_OZP Reason: The function cannot be called since the on-line timeframe is not reaches. Application: This function first calls if the on-line timeframe is reached.

Page 194: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

186 June 2004

20008005 OPT_KERNEL_WRONG_STATE Reason: Execution error! The OPT kernel is not in the right status to execute the command. Application: Query OPT kernel status and act accordingly.

20008006 OPT_LOAD_AP_WRONG_STATE Reason: Execution error! The LOAD application is not in the right status to execute the command. Application: Switch the Load application in the EPP into the IDLE state.

20008010 OPT_OUT_OF_ORDER Reason: The EPP is not ready for operation. Application: Perform OPT personalization.

20008013 OPT_ERR_PINPAD Reason: The EPP found an error when checking a message. Application: Repeat OPT personalization.

20008015 OPT_ERR_REC_8910 Reason: Error in message 8910. Application: Repeat OPT personalization.

20008016 OPT_ERR_AC_8910 Reason: Error in message 8910. The AC is setting. Application: Repeat OPT personalization.

Page 195: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

June 2004 187

20008019 OPT_ERR_CHECK_8910 Reason: Error in message 8910. Application: Repeat OPT personalization.

20008020 OPT_ERR_PUT_GROUP Reason: Failure to load data group into the EPP. Application: Repeat OPT personalization.

20008021 OPT_ERR_REC_8912 Reason: Error in message 8912. Application: Repeat OPT personalization.

20008022 OPT_ERR_CHECK_8912 Reason: Error in message 8912. Application: Repeat OPT personalization.

20008023 OPT_ERR_AC_8912 Reason: Error in message 8912. The AC is setting. Application: Repeat OPT personalization.

280070B2 OPT_FRM_NO_TERMINAL_DATA Reason: No terminal data available. Application: Enter terminal data.

Page 196: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

188 June 2004

280070D0 OPT_FRM_PUT_GROUP Reason: Internal EPP error. Measure: Inform Service. Reload complete EPP if necessary.

280070D1 OPT_FRM_BMP62_TO_LONG Reason: BMP 62 is too big. Measure: Shorten BMP 62 in agreement with personalization office (Chaining).

280070D2 OPT_FRMDATA_BASE_STATE Reason: Incorrect status of the OPT database in the EPP. Measure: Inform Service. Reload complete EPP if necessary.

280070E4 OPT_FRM_MAC Reason: Wrong ISO MAC. Application: Supply correct message.

280070E5 OPT_FRM_AC Reason: Wrong ISO response code. Measure: Check message and agree with personalization office as required.

280070F0 OPT_FRM_APPLICATION_FLOW Reason: Flow control error. Application: Follow specified order of steps.

Page 197: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

June 2004 189

280070F1 OPT_FRM_WRONG_PARAMETER Reason: Wrong parameter transferred. Error in the OPT kernel. Measure: Inform Service.

280070F2 OPT_FRM_PS_NOT_SELECTED Reason: No part HSM was selected. Error in the OPT kernel. Measure: Inform Service.

280070F3 OPT_FRM_INTERNAL_ERROR Reason: Internal EPP error. Measure: Check whether expired the KUR. Inform Service.

280070F5 OPT_FRM_NO_DATA_BASE Reason: No OPT database in the EPP. Measure: Create the database. (Function CscOptCtl() Spec: OPT_START_VI)

280070F7 OPT_FRM_MESSAGE_LENGTH Reason: Wrong command length. Application: Check command.

280070F8 OPT_FRM_MESSAGE_TYPE Reason: Wrong message type. Measure: Inform Service.

Page 198: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

190 June 2004

280070F9 OPT_FRM_ZKA_NUMBER Reason: Wrong ZKA number in the message. Measure: Clarify with personalization office or pre-initializer.

280070FA OPT_FRM_MESSAGE Reason: Wrong ISO message format. Application: Check command.

280070FB OPT_FRM_DATE Reason: Wrong date. Measure: Check date.

280070FC OPT_FRM_AKZ Reason: Wrong ISO processing code. Application: Check command.

280070FE OPT_FRM_NO_LDI Reason: The selected LDI is not available. Application: Select a correct LDI. Load LDI.

28008024 OPT_ERR_PUT_BMP62 Reason: Error in message. Wrong bitmap 62. Application: Repeat OPT personalization.

Page 199: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Online Personalization Terminals (OPT)

June 2004 191

28008405 OPT_FRM_UNKNOWN_CMD Reason: The command is unknown to the EPP. Measure: Inform Service. Reload complete EPP if necessary.

28008408 OPT_FRM_NO_ADF Reason: The required ADF was not loaded into the EPP. Measure: Inform Service. Reload complete EPP if necessary.

Page 200: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

192 June 2004

Page 201: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 193

EPP Firmware Loader (LDE) StClass:

STCLASS_OK No error STCLASS_ERROR_LDE Error of the CSCWLDE.DLL

StCode:

20008000 LDE_MEMORY_ALLOC_ERROR Reason: Not enough memory in the PC. Measure: Put more memory into the PC.

20008001 LDE_FRM_UNDEF_ERROR Reason: The error number reported from the EPP is unknown. Measure: Inform service.

20008003 LDE_WRONG_CTL Reason: Un nown CscLdeCtl() specification. Application: Supply the correct parameter; load more recent LDE.DLL as required.

20008004 LDE_NO_FRMFILE_REL Reason: Firmware file has no release ID. Measure: Copy correct firmware file onto disk.

Page 202: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

194 June 2004

20008005 LDE_SEQUENCE_CANT_OPEN Reason: The file KEYSEQUENCE.TXT is present, possesses however no read- rights. Application: Set the write and read rights for this file.

20008006 LDE_SEQUENCE_NO_KEYFILE Reason: Into KEYSEQUZENCE.TXT specified key file is not in the key directory. Application: Place the appropriate key fiel in the key directory.

20008007 LDE_RKL_TOKENFILE_OPEN_ERR Reason: The remotekeyloading-file is not readable. Application: Set the correct fileattributes.

20008008 LDE_RKL_TOKENFILE_UID_ERR Reason: The UID suitable for the EPP was not found in rkldata.bin. Application: Generate a correkt rkldata.bin.

2000800A LDE_RKL_TOKENIMPORT_ERR Reason: A rkl-token in rkldata.bin was not able to import into the EPP. Application: Generate a correct rkldata.bin.

2000800B LDE_RKL_RKDATA_FORMAT_ERR Reason: Format error in the remotekeyloading-file (rkldata.bin). Application: Generate a correct rkldata.bin.

Page 203: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

June 2004 195

2000800C LDE_RKL_LOAD_RKL_LIB_ERR Reason: The "rkl.dll" can´t be loaded. Application: Install the correct RKL-DLL on the system.

2000800D LDE_CDF_LOAD_OK_INF Reason: A cdf-file was loaded. Application: This is no error message. This entry will be generated after a correct fileloading.

2000800E LDE_ADF_LOAD_OK_INF Reason: A adf-file was loaded. Application: This is no error message. This entry will be generated after a correct fileloading.

2000800F LDE_KEY_LOAD_OK_INF Reason: A key-file was loaded. Application: This is no error message. This entry will be generated after a correct fileloading.

20008010 LDE_RKLDATABIN_RENAME_ERR Reason: The file "rkldata.bin" cannot be renamed as "rkldata.sav". Application: Set the correct fileattributes.

20008011 LDE_RKL_NO_RKLADF_ERR Reason: The adf, suitable for the RKL, is not available on the system. Application: Install a correct RKL-ADF on the EPP.

Page 204: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

196 June 2004

20008012 LDE_V5_ONLY_ONE_MODFILE_ERR Reason: Only EPPV5: in ".../FRM/*.CMD" is more than one firmwarefile. Application: Place only one firmwarefile in ".../FRM/*.CMD".

20008013 LDE_DUKPTDATABIN_RENAME_ERR Reason: The file "dukpt.bin" cannot be renamed as "dukpt.sav". Application: Set the correct file attributes.

20008014 LDE_DUKPT_TOKENFILE_OPEN_ERR Reason: The dukpt-keyloading-file is not readable. Application: Set the correct file attributes.

20008015 LDE_DUKPT_TOKENFILE_UID_ERR Reason: The UID suitable for the EPP was not found in dukpt.bin. Application: Generate a correkt dukpt.bin.

20008016 LDE_DUKPT_TOKENIMPORT_ERR Reason: The DUKPT key was not able to import into the EPP. Application: Generate a correct dukpt.bin.

20008017 LDE_RESCLOAD_NO_FIRMWAREFILE Reason: Not firmware file that is suitable for emergency loading could be found. Application: Place a suitable firmware file in ".../FRM/*.CMD".

Page 205: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

June 2004 197

20008018 LDE_PERMANENTKEY_RENAME_ERR Reason: The file ".../Load_key/Permanentkey.*" cant be renamed. Application: Please set the correct file permissions.

20008019 LDE_PERMANENTKEY_CANT_OPEN Reason: A keyfile in ".../Load_key/Permanentkey.txt" can not be opened. Application: Please set the correct file permissions.

2000801A LDE_PERMANENTKEY_NO_KEYFILE Reason: A keyfile in ".../Load_key/Permanentkey.txt" was not found. Application: Set the suitable key file.

2000801B LDE_RESCUELOADING_NOV5 Reason: Error in rescue loading. Measure: Please change the EPP.

2000801C LDE_RKL_ING_OPEN_ERR Reason: Error in RKL-ING key loading. The RKL ING key file is not loadable. Application: Set correct permissions for this file.

2000801D LDE_RKL_ING_RENAME_ERR Reason: Error in RKL-ING key loading. File "rkldata_ing.bin" cannot be written to. Application: Set correct permissions for this file.

Page 206: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

198 June 2004

2000801E LDE_RKL_ING_UID_ERR Reason: The UID suitable for the EPP was not found in the "rkldata_ing.bin" keyloading file. Application: Supply a "rkldata_ing.bin" file with the UID suitable for the EPP.

2000801F LDE_RKL_ING_HASH_ERR Reason: Incorrect hash value of file "rkldata_ing.bin". Application: Place correct "rkldata_ing.bin" file in the directory.

20008020 LDE_RKL_ING_KCV_ERR Reason: A key KCV value in key file "rkldata_ing.bin" is not correct. Application: Place correct "rkldata_ing.bin" file in the directory.

20008021 LDE_RKL_ING_CFG_ERR Reason: Faulty "rkldata_ing.cfg" file. Application: Supply correct "rkldata_ing.cfg" file.

280070B2 LDE_FRM_NO_TERMINAL_DATA Reason: No terminal data available. Application: Enter terminal data.

28008401 LDE_FRM_FORMAT_ERR Reason: Wrong data format. Application: Check command.

Page 207: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

June 2004 199

28008402 LDE_FRM_PROT_ERR Reason: Protocol error. Application: Repeat command.

28008403 LDE_FRM_HW_LOCK Reason: EPP hardware fault. Measure: Change EPP.

28008404 LDE_FRM_SECURITY_LOCK Reason: EPP locked. Measure: Change EPP.

28008405 LDE_UNKNOWN_CMD Reason: Unknown command. Measure: Inform service.

28008406 LDE_FRM_ADF_TO_LARGE Reason: EPP application is too large. Measure: Inform service.

28008407 LDE_FRM_WRONG_STATE Reason: Command not allowed in this state. Application: Check application.

Page 208: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

200 June 2004

28008408 LDE_FRM_NO_ADF Reason: Required application not available in the EPP. Application: Load application into the EPP.

28008409 LDE_FRM_INTERNAL_ERR Reason: Internal EPP error. Application: Repeat command, if necessary change the EPP.

2800840C LDE_FRM_RAM_OVERFLOW Reason: EPP memory overflow. Application: Check whether any EPP application can be deleted.

2800840D LDE_FRM_LOAD_LEN Reason: Length error when loading an EPP application. Measure: Inform service.

2800840E LDE_FRM_CHECKSUM_ERR Reason: Checksum error when loading an EPP application. Measure: Inform service.

2800840F LDE_FRM_ADF_LOCKED Reason: Selected EPP application disabled.

Page 209: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

June 2004 201

28008413 LDE_FRM_MAC_ERR Reason: MAC error when loading an EPP application. Measure: Inform service.

28008414 LDE_OPT_VERSION_ERR Reason: The firmware (ADF) that will be loaded has a lower version. Measure: Inform service.

28008432 LDE_OPT_KEY_BLOCKED Reason: The key is blocked. Measure: Inform service.

28008434 LDE_OPT_LDI_BLOCKED Reason: The LDI is blocked. Measure: Inform service.

28008435 LDE_OPT_CREATE_ERROR Reason: Can not create OPT database. Measure: Inform service.

28008436 LDE_OPT_NO_ADF Reason: There is no ADF in the EPP. Measure: Inform service.

Page 210: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

202 June 2004

28008437 LDE_OPT_WRONG_STATE Reason: The OPT subsystem is in the wrong state. Measure: Inform service.

2800843B LDE_OPT_PARAM_ERR Reason: The parameter is wrong. Measure: Inform service.

2800843C LDE_OPT_OUTOFORDER Reason: The OPT system is out of order. Measure: Inform service.

28008447 LDE_OPT_VORINIT_ERR Reason: Error in the "VORINIT" state. Measure: Inform service.

28008448 LDE_OPT_REG_ERR Reason: Error while registration. Measure: Inform service.

28008449 LDE_OPT_NO_STD_LDI Reason: The data contains no standard LDI. Measure: Inform service.

Page 211: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

EPP Firmware Loader (LDE)

June 2004 203

2800844C LDE_OPT_NO_DATABASE Reason: There is no OPT database in the EPP. Measure: Inform service.

2800844D LDE_OPT_NO_LDI Reason: The LDI is not in the database. Measure: Inform service.

Page 212: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

204 June 2004

Page 213: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 205

ZKA 3.0 (ZKA) StClass:

STCLASS_OK No error STCLASS_ERROR_ZKA Error of the CSCWZKA.DLL

StCode:

20008000 ZKA_MEMORY_ALLOC_ERROR Reason: Not enough memory in the PC. Measure: Put more memory into the PC.

20008001 ZKA_FRM_UNDEF_ERROR Reason: The error number reported from the EPP is unknown. Measure: Inform service.

20008002 ZKA_GA_RESULT Reason: Invalid result of a dispensing operation supplied. Application: Supply defined value.

20008003 ZKA_UNKNOWN_TAG Reason: Unknown EPP parameter. Application: Supply the correct parameter; load more recent ZKA.DLL as required.

Page 214: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

206 June 2004

20008004 ZKA_CASH_ID Reason: Unknown load function. Application: Load released load function; load more recent ZKA.DLL as required.

20008005 ZKA_NO_FRMFILE_REL Reason: Firmware file has no release ID. Measure: Copy correct firmware file onto disk.

20008006 ZKA_UNKNOWN_BRK Reason: Unknown break reason. Application: Supply valid break reason.

28007080 ZKA_FRM_KEY_NOT_VALID Reason: Invalid key. Application: Load a valid key.

28007082 ZKA_FRM_KEY_NOT_LOADED Reason: Key not loaded. Application: Load the key.

28007083 ZKA_FRM_NO_KGK Reason: The required KGK was not stored. Application: Load the required KGK.

Page 215: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 207

280070A2 ZKA_FRM_PIN_RETRIES Reason: Too frequent incorrect PIN entries. Application: Cancel transaction.

280070A3 ZKA_FRM_PIN_WRONG_L Reason: Incorrect PIN entry. Application: Cancel transaction.

280070A4 ZKA_FRM_LOAD_NOT_POSIBLE Reason: German GeldKarte cannot be loaded. Application: Cancel transaction.

280070B0 ZKA_FRM_INT_ERROR Reason: Internal EPP error. Application: Cancel transaction. Measure: Inform service.

280070B2 ZKA_FRM_NO_TERMINAL_DATA Reason: No terminal data available. Application: Enter terminal data.

280070B3 ZKA_FRM_AMOUNT_RETRIES Reason: Too frequent incorrect amounts. Application: Supply valid amount.

Page 216: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

208 June 2004

280070B5 ZKA_FRM_AMOUNT_TO_LARGE Reason: Amount too large. Application: Supply valid amount.

280070B8 ZKA_FRM_NEED_LOGIN Reason: This function only allowed in operator mode. Application: Request operator login.

280070B9 ZKA_FRM_CURRENCY Reason: Wrong currency code. Application: Supply correct currency code.

280070BA ZKA_FRM_CHIP_TYPE Reason: Wrong chip type. Application: Reject chipcard.

280070C1 ZKA_FRM_WRONG_CC_DATA Reason: The chip data are wrong. Application: Check data.

280070C2 ZKA_FRM_WRONG_CC_MAC Reason: The chip data are wrong. Application: Check MAY key. Check command.

Page 217: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 209

280070E0 ZKA_FRM_ISO_TYPE_L Reason: Wrong ISO message type. Application: Supply correct message.

280070E1 ZKA_FRM_ISO_AKZ_L Reason: Wrong ISO processing code. Application: Supply correct message.

280070E2 ZKA_FRM_ISO_TRACE_L Reason: Wrong ISO trace number. Application: Supply correct message.

280070E3 ZKA_FRM_FRM_CHARGING_FEE Reason: Load fee is to high. Application: Supply valid load fee.

280070E4 ZKA_FRM_ISO_MAC_L Reason: Wrong ISO MAC. Application: Supply correct message.

280070E5 ZKA_FRM_ISO_RESP_L Reason: Wrong ISO response code. Application: Supply correct message.

Page 218: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

210 June 2004

280070E6 ZKA_FRM_ISO_BMP62 Reason: ISO error in BMP 62. Application: Supply correct message.

280070E7 ZKA_FRM_ISO_BMP62_AMOUNT Reason: ISO amount error in BMP 62. Application: Supply correct message.

280070E8 ZKA_FRM_ISO_COND_CODE Reason: Wrong ISO condition code. Application: Supply correct message.

280070E9 ZKA_FRM_ISO_BMP58 Reason: ISO error in BMP 62. Application: Supply correct message.

280070EA ZKA_FRM_ISO_CARD_WRONG Reason: Wrong chipcard. Application: Reject chipcard.

280070EB ZKA_FRM_BANK_NUM_L Reason: Wrong ISO card accept identification code. Application: Supply correct message.

Page 219: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 211

280070EF ZKA_FRM_NO_DATA_BLOCK Reason: No further data blocks available in the EPP. Measure: Inform service.

280070F0 ZKA_FRM_FLOW_CONTROL_L Reason: Flow control error. Application: Follow specified order of steps.

280070F2 ZKA_FRM_MESSAGE_STRUCT Reason: Wrong message format. Application: Supply correct message.

280070F3 ZKA_FRM_CMD_NOT_POSIBLE Reason: Command not allowed. Application: Suppy correct command.

280070F4 ZKA_FRM_ADF_MAC Reason: Wrong MAC of internal command. Application: Repeat command; inform Service is necessary.

280070F5 ZKA_FRM_AMOUNT Reason: Wrong amount. Application: Check amount; supply correct amount.

Page 220: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

212 June 2004

280070F6 ZKA_FRM_ADF_STATE Reason: Invalid internal EPP state.

280070F7 ZKA_FRM_CMD_LEN Reason: Wrong command length. Application: Check command.

280070F8 ZKA_FRM_PARA_CASH_ID Reason: Wrong parameter CACH-ID. Application: Check command.

280070F9 ZKA_FRM_ADF_LOCKED_L Reason: LOAD application in the EPP disabled. Application: Loading from chipcard not available.

280070FA ZKA_FRM_ISO_MESSAGE Reason: Wrong ISO message format. Application: Check command.

280070FB ZKA_FRM_CMD_CODE Reason: Wrong command code. Application: Check command.

Page 221: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 213

280070FC ZKA_FRM_CCC Reason: Wrong chip card command. Application: Check command.

280070FD ZKA_FRM_RND_NUMBER Reason: Wrong encrypted random number. Application: Check command.

280070FE ZKA_FRM_TID Reason: Wrong terminal ID. Application: Supply correct terminal ID.

280070FF ZKA_FRM_FUNCTION_L Reason: Function not allowed. Application: Check command.

28007191 ZKA_FRM_PARA_MODE Reason: Wrong parameter "operating mode". Application: Ensure correct "operating mode" parameter setting.

28007192 ZKA_FRM_PARA_MODE_AUT Reason: Wrong parameter "operating mode". Application: Ensure correct "operating mode" parameter setting.

Page 222: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

214 June 2004

28007193 ZKA_FRM_PARA_DATE_TIME Reason: Parameter "date-time" is wrong. Application: Supply correct value.

28007194 ZKA_FRM_PIN_FORMAT Reason: Unknown PIN format. Application: Supply valid PIN format.

28007195 ZKA_FRM_NO_PIN Reason: No PIN input. Application: Enter PIN.

28007196 ZKA_FRM_WRONG_PIN Reason: PIN does not match card data. Application: Enter correct PIN.

28007198 ZKA_FRM_WRONG_KEY Reason: No valid key available (data expired). Measure: Load validated key.

28007199 ZKA_FRM_FBZ Reason: Operating error counter overflow. Measure: Reject chipcard.

Page 223: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 215

2800719A ZKA_FRM_RESULT Reason: Unknown result code. Application: Supply valid result code.

2800719F ZKA_FRM_MAC Reason: MAC for the supplied command is wrong. Measure: Inform service.

280071E0 ZKA_FRM_ISO_TYPE Reason: Wrong ISO message type. Application: Supply correct message.

280071E1 ZKA_FRM_ISO_AKZ Reason: Wrong ISO processing code. Application: Supply correct message.

280071E2 ZKA_FRM_ISO_TRACE Reason: Wrong ISO trace number. Application: Supply correct message.

280071E4 ZKA_FRM_ISO_MAC Reason: Wrong ISO MAC. Application: Supply correct message.

Page 224: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

216 June 2004

280071E5 ZKA_FRM_ISO_RESP Reason: Wrong ISO response code. Application: Supply correct message.

280071EB ZKA_FRM_ISO_BANK_NUM Reason: Wrong card acceptor identification code. Application: Supply or enter correct card acceptor identification code.

280071EF ZKA_FRM_ISO_TID Reason: Wrong terminal ID. Application: Supply or enter correct terminal ID.

280071F0 ZKA_FRM_FLOW_CONTROL Reason: Flow control error. Application: Call correct (valid) function.

280071F2 ZKA_FRM_MESSAGE_STRUCT Reason: Wrong message format. Application: Supply correct message.

280071F5 ZKA_FRM_AMOUNT Reason: Wrong amount. Application: Supply correct amount.

Page 225: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 217

280071F6 ZKA_FRM_ADF_STATE Reason: Invalid internal EPP state. Application: Reload EPP application .

280071F7 ZKA_FRM_CMD_LEN Reason: Wrong command length. Application: Supply correct command.

280071F9 ZKA_FRM_ADF_LOCKED Reason: Authorization application in EPP disabled. Application: Reload EPP application.

280071FB ZKA_FRM_CMD_CODE Reason: Wrong command code. Measure: Inform service.

280071FD ZKA_FRM_RND_NUMBER Reason: Wrong encrypted ransom number. Measure: Inform service.

280071FF ZKA_FRM_FUNCTION Reason: Function not supported by the EPP. Measure: Inform service.

Page 226: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

218 June 2004

28008401 ZKA_FRM_FORMAT_ERR Reason: Wrong data format. Application: Check command.

28008402 ZKA_FRM_PROT_ERR Reason: Protocol error. Application: Repeat command.

28008403 ZKA_FRM_HW_LOCK Reason: EPP hardware fault. Measure: Change EPP.

28008404 ZKA_FRM_SECURITY_LOCK Reason: EPP locked. Measure: Change EPP.

28008405 ZKA_UNKNOWN_CMD Reason: Unknown command. Measure: Inform service.

28008406 ZKA_FRM_ADF_TO_LARGE Reason: EPP application is too large. Measure: Inform service.

Page 227: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

June 2004 219

28008407 ZKA_FRM_WRONG_STATE Reason: Command not allowed in this state. Application: Check application.

28008408 ZKA_FRM_NO_ADF Reason: Required application not available in the EPP. Application: Load application into the EPP.

28008409 ZKA_FRM_INTERNAL_ERR Reason: Internal EPP error. Application: Repeat command, if necessary change the EPP.

2800840C ZKA_FRM_RAM_OVERFLOW Reason: EPP memory overflow. Application: Check whether any EPP application can be deleted.

2800840D ZKA_FRM_LOAD_LEN Reason: Length error when loading an EPP application. Measure: Inform service.

2800840E ZKA_FRM_CHECKSUM_ERR Reason: Checksum error when loading an EPP application. Measure: Inform service.

Page 228: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ZKA 3.0 (ZKA)

220 June 2004

2800840F ZKA_FRM_ADF_LOCKED Reason: Selected EPP application disabled.

28008413 ZKA_FRM_MAC_ERR Reason: MAC error when loading an EPP application. Measure: Inform service.

Page 229: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 221

Printer (general) StClass:

STCLASS_OK No error STCLASS_ERROR_PRT Error of the CSCWPRT.DLL

StCode:

20008001 PRT_NO_DLL_FILE Reason: No entry was found in Registry under the keyword DLLNAME. Measure: Check the keyword DLLNAME in Registry.

20008002 PRT_PRT_FILE_NOT_FOUND Reason: The printer control code file e.g. ND97.PRN, was not found. Measure: Check whether the printer control code file is entered in <CSCROOT>\BIN. Check whether the correct name has been entered in Registry under the keyword PRNFILE (e.g. ND97 for ND97-PRN).

20008003 PRT_PRT_FILE_OPEN_FAILED Reason: The printer control code file could not be opened. Measure: Check the access rights and attributes of this file.

20008004 PRT_BAD_PRT_FILE Reason: Bad format of the printer control code file. Measure: Copy the printer control code file from the release diskette, e. g. ND97.PRN, into <CSCROOT>\BIN on the CSC.

Page 230: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Printer (general)

222 June 2004

20008005 PRT_NO_MACROEND Reason: Invalid format of the macro. Application: Check the macro definition in the application program.

20008006 PRT_FMT_FILE_NOT_FOUND Reason: The format file is not available. Application: Check the FMT file specified by the application. Measure: Check whether the FMT file specified by the application is available.

20008007 PRT_FMT_FILE_OPEN_FAILED Reason: OPEN error of the format file. Measure: Check the access rights and attributes of this file.

20008008 PRT_BAD_FMT_FILE Reason: Bad format of the format file. Measure: Translate the format file using the FMTGEN.EXE tool.

20008009 PRT_FALSE_STATUS_LEN Reason: Error while transmitting the status buffer. Application: Check the length specification in the status command. Measure: The printer can send an invalid length, therefore check the printer hardware

Page 231: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Printer (general)

June 2004 223

2000800A PRT_BUFFER_TO_SHORT Reason: The print buffer is too small. Application: Split the print command into a number of print commands.

2000800B PRT_NO_TEXT_NUMBER Reason: No text from the FMT file found. Application: An invalid descriptor number in the FMT file was referenced. Measure: Check whether the correct FMT file is available.

2000800C PRT_NO_PRNSYM Reason: No macro symbol was found. Measure: Check whether a correct symbol such as # was entered in Registry under the PRNSYM keyword. This symbol is used to identify a macro.

2000800D PRT_INVALID_TIME Reason: An invalid monitoring time is entered in the TIME keyword in Registry. Measure: Check Registry.

2000800E PRT_INVALID_AGGREGATE Reason: Invalid printer aggregate. Application: Check whether a correct aggregate name was passed from the application. Measure: Check the aggregate in Registry.

Page 232: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Printer (general)

224 June 2004

2000800F PRT_MAX_SPACE Reason: Formatting error (internal error). Measure: Report the error log of this entry to Service.

20008010 PRT_PRT_DLL_NOT_FOUND Reason: The printer-specific DLL could not be found. Measure: Check whether the printer-specific DLL is in <CSCROOT>\DLL. Check whether the correct DLL name is entered in Registry with the keyword DLLNAME.

20008011 PRT_PRT_DLL_OPEN_FAILED Reason: The printer-specific DLL could not be opened. Measure: Check the access rights and attributes of this file.

20008012 PRT_INVALID_INI_PARAM Reason: Error in Registry section [CSCPRT]. Measure: Check Registry.

20008013 PRT_FORMAT_ERROR Reason: Unknown string format specification. Application: Check the print buffer in the application program.

Page 233: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Printer (general)

June 2004 225

20008014 PRT_INVALID_LOGICAL_ID Reason: The logical ID specified in the Open/GetRelease command is invalid. Application: Check application program. Check the logical ID in Registry. Measure: Consult with the application programmer. Modify Registry if necessary.

20008015 PRT_MALLOC_ERROR Reason: Memory, used for formatting could not be allocated. Application: Check the memory size.

20008100 PRT_INVALID_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in Registry. Measure: Check the parameters LED, LED_FLASH and LED_FREQ in Registry.

StWarn:

20009000 PRT_WARN_LED Reason: The device handler was configured to switch LEDs when paper output. An error occurred when accessing the SEL DH to switch the LEDs. Measure: Check the configuration of PRT and SEL device handler.

Page 234: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

226 June 2004

Page 235: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 227

ND05 printer / PMxx / Document reader StClass:

STCLASS_OK No error STCLASS_ERROR_ND05 Error of the CSCWND05.DLL

StCode:

20008117 PRT_WRONG_MODE Reason: The application try to use a passbook API-function in the receipt mode or a receipt API-function in the passbook mode. Application: Check the passbook handling and the receipt handling.

20008118 PRT_ZEKOSA_WRITE_ERROR Reason: An error has been detected during the ZEKOSA write job. Application: Retry write job; if error recurs: eject passbook. Measure: If the error occurs frequently: check the printer device and, if necessary, replace it.

20008119 PRT_ZEKOSA_READ_LRC Reason: The LRC character of the ZEKOSA data does not match the recording on the ZEKOSA. Application: Repeat read job; if error occurs again: eject passbook. Measure: If the error occurs frequently: check the printer device and, if necessary, replace it.

Page 236: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

228 June 2004

20008120 PRT_ZEKOSA_READ_PARITY Reason: A parity error has been detected on the ZEKOSA track during a read job. Application: Repeat read job; if error occurs again: eject passbook. Measure: If the error occurs frequently: check the printer device and, if necessary, replace it.

20008121 PRT_ZEKOSA_READ_NO_DATA Reason: The passbook contains no readable data in the ZEKOSA track specified in the job or passbook invalid inserted. Application: Eject passbook.

20008122 PRT_ZEKOSA_READ_NO_STX Reason: The start character of the ZEKOSA data specified in the job is incorrect or the ZEKOSA reader unit is defective. Application: Eject passbook. Measure: If the error occurs frequently: check the printer device and, if necessary, replace it.

20008123 PRT_ZEKOSA_READ_ERROR Reason: Data error on ZEKOSA track. Missing or incorrect end character, ZEKOSA data. Application: Eject passbook.

28008100 PRT_NO_PAPER Reason: No form inserted. Application: Respond as required by application.

Page 237: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

June 2004 229

28008101 PRT_PAPER_JAM Reason: Form did not leave form station after an eject command (photosensors do not become free; form foot has been run over; paper residues on photosensors; manual manipulation of vertical position; excessive form length; faulty logic; photosensors, cables, drives; stiffly moving or faulty mechanism). Measure: Open printer and remove form manually. Clean photosensors with compressed air or soft cleaning brush, if required. Inform Customer Service if error occurs again.

28008102 PRT_DATA_TRANSMISSION_ERROR Reason: Error during communication with printer. Interface parameters (baud rate, data bits, stop bits) set incorrectly. Application: Check interface transmission parameters. Measure: Check hardware / line.

28008103 PRT_SW_SYNTAX_ERROR Reason: Internal error in the printer device control logic. Measure: Call Customer Service.

28008104 PRT_SW_SEMANTIK_ERROR Reason: Internal error in the printer device control logic. Measure: Call Customer Service.

28008105 PRT_NO_ANSWER Reason: No message from Document reader module. Error see operator panel document reader. Otherwise V.24 line faulty. Measure: Check printer, check line. Switch printer online. Inform Customer Service if error occurs again.

Page 238: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

230 June 2004

28008106 PRT_HW_MAIN_BOARD_ERROR Reason: Hardware error in the printer controller. Measure: Call Customer Service.

28008107 PRT_HW_ERROR_HOR Reason: Error on initializing or in running operation. Cause: - faulty motor - open connecting cables - faulty photosensor - logic error on main board - stiffly moving mechanism - faulty receiver in carrier - contamination in the region of the platen. Measure: Remove contamination or paper residues in the region of the platen. Inform Customer Service if error occurs again.

28008108 PRT_PAPER_WIDE Reason: Print job exceeds right forms edge. Forms width does not fit current application. Application: Insert lager form or check application.

28008109 PRT_HW_ERROR_ZEKOSA Reason: Hardware error in ZEKOSA unit. Measure: Call Customer Service.

Page 239: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

June 2004 231

2800810A PRT_HW_ERROR_BELEG Reason: Error on initializing or while operating the motor in the document feeder. Cause: - faulty motor - open connecting cables - faulty photosensor - logic error on main board - binding mechanism. Measure: Call Customer Service.

2800810B PRT_NO_PAPER_ACCEPT Reason: Inserted form was rejected by printer. Application: Respond as required by application.

2800810C PRT_REJECT_SLOT_FULL Reason: Message which indicates that the set limit for the reject box has been exceeded. Measure: Empty the reject box. Possibly increase capacity of reject box via software.

2800810D PRT_WRONG_STATUS Reason: Hardware error printer Measure: Call Customer Service.

2800810E PRT_PRINTER_STOP Reason: Hardware error (cover open, stop key pressed, initialization) The printer is in a recovery routine. Application: Wait a moment and try again.

Page 240: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

232 June 2004

2800810F PRT_PRINTER_ERROR Reason: Hardware error, printer offline Measure: Call Customer Service.

28008110 PRT_PAPER_TRAY Reason: Customer did not remove document from output slot or there is still a form in the print unit. Application: Move document into reject box.

28008111 PRT_MORE_ERRORS Reason: Printer hardware error. Application: Terminate applications requiring the printer. Call printer status. Measure: Check printer (self-test), if necessary inform service.

28008112 PRT_NO_PAPER_REJECT Reason: Paper jam in paper path. Measure: Check paper path, sensor. Remove paper jam.

28008113 PRT_WRONG_PARAMETER Reason: Invalid parameter value. Application: Check application program.

28008114 PRT_SHUTTER_ERROR Reason: Shutter error. Measure: Check the shutter.

Page 241: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

June 2004 233

28008115 PRT_PAPER_LENGTH Reason: The document is too short. It cannot processed from the device. Application: Remove document.

28008116 PRT_WRONG_PAGE Reason: The printer cannot read a page number from a passbook. Application: Check the correct read position of page code. Measure: - Check the availability of the page code. - Check the page code position on the passbook side.

28008124 PRT_WRONG_LINE Reason: The optical mark reader cannot find the first printed line within a defined read area of a passbook. Measure: Check the correct read area position. Inform Customer Service if error occurs again.

28008125 PRT_NO_PARK_STATION Reason: Try to transport a passbook/document into the park position, although the park box is not available. Application: Check application program (test of the printer configuration). Measure: Check the availability of the park box.

28008126 PRT_NO_PAPER_PARKED Reason: Try to transport a passbook/document from the park position into the print position, although the park position is empty. Application: Check application program.

Page 242: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

234 June 2004

28008127 PRT_PAPER_PARKED Reason: Try to transport a passbook/document into the park position, although the park position is not empty. Application: Check application program.

28008128 PRT_DISPENSE_BOX_NOT_OK Reason: Dispenser box is empty or is not available. Application: Check the dispenser box status. Measure: Check the availability of the dispense box.

28008129 PRT_UNIT_NOT_AVAILABLE Reason: The called printer hardware unit is not available. Application: Check the printer capabilities. Measure: Check the availability of the printer hardware unit.

2800812A PRT_SYNTAX_ERROR_ZEKOSA Reason: The printer get ZEKOSA data out of the valid data area (0x30 - 0x3F). Application: Check the write ZEKOSA data handling.

2800812B PRT_COVER_OPEN Reason: Cover was open. Measure: Check the cover or check the cover switch.

Page 243: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

June 2004 235

2800812C PRT_TURN_UNIT_ERROR Reason: Error in the paper turn unit: The passbook was prevented from closing. Application: Try to find a valid page and to repeat the page-turn-over procedure. Output the passbook if the error keeps occurring.

2800812D PRT_UNIT_ERROR_RETRACT Reason: Error in the paper turn unit: The passbook was prevented from closing; however, the passbook had to be retracted in the park station. Application: Abort transaction.

2800812E PRT_WRONG_PAGE_LINE Reason: By the using of the command "line finding and reading of page number" the optical mark reader cannot find the first printed line within a defined read area of a passbook or cannot read a page number from a passbook. Application: - Check the availability of the page code. - Check the page code position on the passbook side. - Check the correct read area position. Inform Customer Service if error occurs again.

2800812F PRT_WRONG_OMR_CMD Reason: By the using of the command "switch the alternate algorithm for last line finding" the function cannot executed, because the called printer hardware does not make the function available. For executing the command the following components are necessary: - printer firmware PMxx 97597-04 - auxiliary electronics 04 - OMR firmware > 03 Measure: Check the availibility of the described components. If necessary inform Customer Service.

Page 244: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND05 printer / PMxx / Document reader

236 June 2004

28008130 PRT_ADD_ON_BOARD_ERROR Reason: Error on add on electronic or turn unit: Cause: - no response of the add on electronic - turn unit error - faulty photosensor in the region of the platen. Measure: Check the turn unit or the photosensor in the region of the platen or the add on electronic. Inform Customer Service if error occurs again.

Page 245: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 237

Scanner module (SCAN) StClass:

STCLASS_OK No error STCLASS_ERROR_SCAN Error of the CSCWSCAN.DLL

StCode:

20008000 SCAN_DRIVER_NOT_FOUND Reason: Recognition unit driver not found. Measure: Check configuration.

20008001 SCAN_DRIVER_OPEN_FAILED Reason: Cannot open recognition unit driver. Measure: Check configuration.

2000800B SCAN_INVALID_BOS_VERSION Reason: The loaded scanner firmware does not match to the scanner hardware. Measure: - Check the loaded Basic Operating System (BOS). The version of the loaded BOS must be greater than 5.0. - The BOSKFZ version will be needed for the a DIN A4 scanner hardware and the BOS_AT version will be needed for the DIN A6 scanner hardware.

Page 246: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

238 June 2004

2000800C SCAN_INVALID_IMAGE_FORMAT Reason: The desired image format does not match the scanner hardware. A DIN-A4 scanner hardware can only work in binary mode. No image loaded. Measure: Check the image format specification of the CscPrtImage function. A form must first be read (scanned) before a image can be used.

2000800D SCAN_TMP_FILE_FAILED Reason: The scanner device handler is uses the temporary file IMAGE.TMP in the path CSCW32 or <CSCROOT> for the image handling. This file cannot open. Measure: Check the validity of the path CSCW32 or <CSCROOT>.

2000800E SCAN_OUT_FILE_OPEN_FAILED Reason: The specified image output file cannot open. Measure: Check the validity of the output file and the appropriate path.

2000800F SCAN_IMAGE_CONVERT_FAILED Reason: The scanner device handler cannot convert the received image to the desired image format. Measure: Report the error log of this entry to service.

20008010 SCAN_INVALID_IMAGE_SECTION Reason: The scanner found no image section for the desired read area or the scanner does not recognize the form type. Measure: Check the loaded form description if the desired read area is defined.

Page 247: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

June 2004 239

20008100 SCAN_RUL_INVALID_FILENAME Reason: Filename in command line is invalid. Measure: Check the loader command line.

20008101 SCAN_RUL_INVALID_CMD_LINE_ARG Reason: Loader command line argument is invalid. Measure: Check the loader command line.

20008102 SCAN_RUL_CTRL_FILE_OPEN_ERROR Reason: Cannot open the control file. Measure: Check the control file.

20008103 SCAN_RUL_DLD_FILE_OPEN_ERROR Reason: The download file (name, path) specified in the control file could not be opened. Measure: Check the download file.

20008104 SCAN_RUL_CTRL_FILE_READ_ERROR Reason: Cannot read the control file. Measure: Check the control file,

20008105 SCAN_RUL_DLD_FILE_READ_ERROR Reason: Cannot read a download file. Measure: Check the download file.

Page 248: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

240 June 2004

20008106 SCAN_RUL_CTRL_FILE_INVALID_CMD Reason: Found invalid command within the download file. Measure: Check the download file

20008107 SCAN_RUL_DRV_WRITE_ERROR Reason: The loader cannot write a command to the recognition unit. Measure: Restart system and start loader again.

20080001 SCAN_RU_ILL_CMD Reason: Invalid call to recognition unit driver. Measure: Report the error log of this entry to Service.

20080002 SCAN_RU_ACCESS_ERROR Reason: Insufficient memory access rights or invalid pointer. Measure: Report the error log of this entry to Service.

20080003 SCAN_RU_BOARD_MISSING Reason: Recognition unit not found. Measure: Check the parameters of the recognition unit driver. If they are correct, check the hardware.

20080004 SCAN_RU_INVALID_CMD_FORMAT Reason: The recognition unit driver received invalid data from the recognition unit. Application: Abort the current transaction. Measure: Check the hardware if necessary.

Page 249: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

June 2004 241

20080005 SCAN_RU_DATA_AVAILABLE Reason: A command could not be transmitted to the recognition unit. Application: Abort the current transaction. Measure: Check the hardware if necessary.

20080006 SCAN_RU_NOT_READY Reason: Recognition unit is not ready to communicate with the driver. Application: Abort the current transaction. Measure: Check the hardware if necessary.

20080007 SCAN_RU_CS_ERROR Reason: Checksum error reported by the recognition unit. Application: Abort the current transaction. Measure: Check the hardware if necessary.

20080008 SCAN_RU_CS_TIMEOUT Reason: Timeout during checksum calculation. Application: Abort the current transaction. Measure: Check the hardware if necessary.

Page 250: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

242 June 2004

20080009 SCAN_RU_COMM_TIMEOUT Reason: Timeout during a data transfer from/to the recognition unit. Application: Abort the current transaction. Measure: Check the hardware if necessary.

2008000A SCAN_RU_READ_TIMEOUT Reason: A READ command could not be executed in the specified monitoring time. Application: Abort the current transaction. Measure: Check the hardware if necessary.

2008000B SCAN_RU_INVALID_OUTLEN Reason: Recognition unit driver called with an insufficient buffer lenght. Application: Abort the current transaction. Measure: Report the error log of this entry to Service.

2008000C SCAN_RU_INVALID_PTR Reason: Driver called with an invalid pointer. Measure: Report the error log of this entry to Service.

2008000D SCAN_RU_NO_STS Reason: State of the recognition unit could not be read. Measure: Check the parameters of the recognition unit driver. If they are correct, check the hardware.

Page 251: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

June 2004 243

2008000E SCAN_RU_DMA_TIMEOUT Reason: Timeout at DMA transfer. Application: Abort the current transaction. Measure: Check if there is a DMA conflict. Check the hardware if necessary.

28008002 SCAN_INVALID_QUITT Reason: The recognition unit returns an unexpected acknowledge. Application: Abort the current transaction. Measure: Check the recognition unit if necessary.

28008003 SCAN_CHECKSUM_ERROR Reason: Checksum error. Application: Abort the current transaction. Measure: Check the recognition unit if necessary.

28008004 SCAN_INVALID_FORM Reason: The form size of a scanned document is invalid. Application: Abort the current transaction. Measure: Check the form.

28008005 SCAN_HARDWARE_ERROR Reason: Scanner hardware error. Measure: Check the hardware.

Page 252: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner module (SCAN)

244 June 2004

28008006 SCAN_FIRMWARE_NOT_LOADED Reason: The scanner firmware is not loaded. Measure: Start the firmware loader.

28008007 SCAN_TIMEOUT_VID_SCAN Reason: The scanner module cannot recognize a transported form. Application: Abort the current transaction. Measure: Check the transport.

28008008 SCAN_HARDWARE_XM_ERROR Reason: Scanner hardware error (internal error) Application: Abort the current transaction. Measure: Check the recognition unit if necessary.

28008009 SCAN_HARDWARE_UQ_ERROR Reason: Scanner hardware error (internal error) Application: Abort the current transaction. Measure: Check the recognition unit if necessary.

2800800A SCAN_DRV_WRITE_ERROR Reason: Cannot write a command to the recognition unit. Application: Abort the current transaction. Measure: Check the recognition unit if necessary.

Page 253: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 245

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer StClass:

STCLASS_OK No error STCLASS_ERROR_ND71 Error of the CSCWND71.DLL

StCode:

20008009 PRT_FALSE_STATUS_LEN Reason: Error while transmitting the status buffer. Application: Check the length specification in the status command. Measure: The printer can send an invalid length, therefore check the printer hardware.

20008201 LDR_INI_FILE_OPEN_FAILED Reason: Cannot open the control file ND9X.INI in the appropriate directory. Measure: Check the control file ND9X.INI.

20008202 LDR_INI_FILE_READ_ERROR Reason: Cannot read the control file ND9X.INI. Measure: Check the control file ND9X.INI.

20008203 LDR_INVALID_FILE Reason: Cannot open a file or checksum of a file to be loaded is not correct. Measure: The file is probably corrupted. Check the file.

Page 254: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

246 June 2004

20008204 LDR_FILE_ACCESS_ERROR Reason: Cannot read the file to be loaded. Measure: Check the file.

20008205 LDR_INVALID_MODID Reason: File to be loaded has an invalid module id. Measure: Check the file.

20008206 LDR_FRM_LOADER_NOT_READY Reason: The expected response of the Firmware Loader is not correct. Application: Repeat the last API-function to start the download process again. If the error occurs again report this error log to Service.

20008207 LDR_INVALID_LOADED_FILE Reason: Invalid logo type by the loading of a logo for the printer ND9C or downloaded file data do not reach the firmware controller correctly. Application: Repeat the last API-function to start the download process again. If the error occurs again report this error log to Service. Measure: Check the valid of the logo file for the printer ND9C.

20008208 LDR_INVALID_FIRMWARE Reason: A loaded file does not fit to the printer hardware, for example loading a ND9E firmware file into a ND9C printer hardware. Measure: Check the entered files in the control file ND9X.INI.

Page 255: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

June 2004 247

28008100 PRT_DEVICE Reason: Printer hardware error. Application: Terminate applications requiring the printer. Measure: Check printer (self-test), if necessary inform service.

28008101 PRT_DEVICE_CMD_REC Reason: Loss of command after device error. A printer command was not correctly processed. Application: By sensing the status, check whether the printer is OK again, then repeat the command. Alternatively remove the printer from service. Measure: Check the hardware

28008102 PRT_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

28008103 PRT_FORMAT_LOGO Reason: Syntax error in the ESCAPE sequence for loading LOGO. Application: Transfer correct LOGO format

28008104 PRT_PARITY Reason: A parity error is returned from the printer when faulty characters are received. Measure: Check the hardware. Inform Customer Service if error occurs again.

Page 256: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

248 June 2004

28008105 PRT_CHECKSUM Reason: A checksum error is set when - the logo area, - the loadable character set - the parameter area have a faulty checksum. Application: Change application program. Check checksum. Measure: Check the hardware (Zero power Ram). Issue reset job or press key Reset form.

28008106 PRT_POWER_LOST Reason: Short-term power failed on during operation. Application: If necessary, repeat the print. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008107 PRT_BON_PAPER_END Reason: Paper-out condition or paper jam. The current form is still printed. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam.

28008108 PRT_BON_PAPER_END_FIN Reason: Loss of command after receipt paper end. A command was sent from the application, although PRT_BON_PAPER_END was signaled. Measure: Replenish receipt paper roll and repeat command.

Page 257: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

June 2004 249

28008109 PRT_BON_PAPER_JAM Reason: Receipt paper jam. Receipt could not be correctly processed. Measure: Check paper feed.

2800810A PRT_BON_PAPER_JAM_CMD_REC Reason: Loss of command after paper jam. The command was sent and could not be correctly executed because of paper jam. Measure: Check paper feed and repeat command.

2800810B PRT_JOURNAL_PAPER_END Reason: Paper-out condition or paper jam. The current form is still printed Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam

2800810C PRT_JOURNAL_PAPER_END_FIN Reason: Loss of command after receipt paper end. A command was sent from the application, although PRT_JOURNAL_PAPER_END was signaled. Measure: Replenish journal roll and repeat command.

2800810D PRT_JOURNAL_PAPER_TEAR Reason: Journal paper tear. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam.

Page 258: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

250 June 2004

2800810E PRT_JOURNAL_PAPER_TEAR_CMD_REC Reason: Loss of command after receipt paper end. A command was sent from the application, although PRT_JOURNAL_PAPER_TEAR was signaled. Measure: Load journal roll again and repeat command.

2800810F PRT_SWITCH Reason: The door is not properly closed Measure: Close door; if necessary check printer disconnecting switch.

28008110 PRT_SWITCH_CMD_REC Reason: Loss of command because of open CSC door. A command was sent from the application, although PRT_SWITCH was signaled. Measure: Close CSC door and repeat command.

28008111 PRT_MORE_ERRORS Reason: Printer hardware error Application: Terminate applications requiring the printer. Call printer status. Measure: Check printer (self-test), if necessary inform service.

28008112 PRT_MARK_ERROR Reason: By activated mark, recognition a mark is not found. Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

Page 259: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND71, ND74, ND98, ND9A, ND9C, ND9E, TH30 printer

June 2004 251

StWarn:

28000001 PRT_WARN_BON_PAPER_LOW Reason: "Receipt paper low" warning. The device only contains the preset quantity of receipts. Application: Inform operator to load paper. Measure: The next time the CSC is maintained, the paper supply for receipts should be replenished.

28000002 PRT_WARN_JOURNAL_PAPER_LOW Reason: Journal paper low warning The device only contains the preset minimum quantity of paper. Application: Inform operator to load paper. Measure: The next time the CSC is maintained, the paper supply for receipts should be replenished.

28000003 PRT_WARN_BON_SENSOR Reason: There is still a receipt in the output chute at an OPEN on the printer. This may cause a paper jam during the next transaction. Application: Inform operator to remove the receipt. Measure: Remove the receipt.

Page 260: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

252 June 2004

Page 261: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 253

ND79 printer StClass:

STCLASS_OK No error STCLASS_ERROR_ND79 Error of the CSCWND79.DLL

StCode:

28008100 PRT_DEVICE Reason: Printer hardware error Application: Terminate applications requiring the printer. Measure: Check printer (self-test), if necessary inform service

28008101 PRT_DEVICE_CMD_REC Reason: Loss of command after device error. A printer command was not correctly processed. Application: By sensing the status, check whether the printer is OK again, then repeat the command. Alternatively remove the printer from service. Measure: Check the hardware

28008103 PRT_FORMAT_LOGO Reason: Syntax error in the ESCAPE sequence for loading LOGO. Application: Transfer correct LOGO format

Page 262: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND79 printer

254 June 2004

28008104 PRT_PARITY Reason: A parity error is returned from the printer when faulty characters are received. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008106 PRT_POWER_LOST Reason: Short-term power failed on during operation. Application: If necessary, repeat the print. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008107 PRT_BON_PAPER_END Reason: Paper-out condition or paper jam. The current form is still printed. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam.

28008108 PRT_BON_PAPER_END_FIN Reason: Loss of command after receipt paper end. A command was sent from the application, although PRT_BON_PAPER_END was signaled. Measure: Replenish receipt paper roll and repeat command.

28008109 PRT_BON_PAPER_JAM Reason: Receipt paper jam. Receipt could not be correctly processed. Measure: Check paper feed.

Page 263: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND79 printer

June 2004 255

2800810A PRT_BON_PAPER_JAM_CMD_REC Reason: Loss of command after paper jam. The command was sent and could not be correctly executed because of paper jam. Measure: Check paper feed and repeat command.

28008111 PRT_MORE_ERRORS Reason: Printer hardware error Application: Terminate applications requiring the printer. Call printer status. Measure: Check printer (self-test), if necessary inform service.

28008112 PRT_SERVICE_POSITION Reason: The printer is in service position. Application: Place printer in working position.

28008113 PRT_USER_ERROR Reason: Defective control instruction. Programming error Incorrect control sequence or paper low message limit exceeded. Application: Check application program.

28008114 PRT_SERVICE_POSITION_CMD_REC Reason: Job lost while "printer in service position". A job was sent although the printer was still in service position. Application: Place printer in working position and repeat job.

Page 264: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND79 printer

256 June 2004

StWarn:

28000001 PRT_WARN_BON_PAPER_LOW Reason: "Receipt paper low" warning. The device only contains the preset quantity of receipts. Application: Inform operator to load paper. Measure: The next time the CSC is maintained, the paper supply for receipts should be replenished.

28000003 PRT_WARN_BON_SENSOR Reason: There is still a receipt in the output chute at an OPEN on the printer. This may cause a paper jam during the next transaction. Application: Inform operator to remove the receipt. Measure: Remove the receipt.

28000004 PRT_WARN_LAST_BON Reason: Receipt paper low warning (last receipt printing). The last receipt to be processed is being printed. Measure: Inform operator to load paper.

Page 265: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 257

ND75, ND75S, ND94 printer StClass:

STCLASS_OK No error STCLASS_ERROR_ND94 Error of the CSCWND94.DLL

StCode:

20008111 PRT_MORE_ERRORS Reason: Printer hardware error Application: Terminate applications requiring the printer. Call printer status. Measure: Check printer (self-test), if necessary inform service.

28008100 PRT_VOLTAGE Reason: Hardware error: error in the low-voltage power supply Measure: Check hardware and replace power supply/controller if required.

28008101 PRT_CARRIER Reason: The carrier was moved manually or does not reach its home position. Measure: Issue reset job or press key Reset form.

28008102 PRT_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

Page 266: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND75, ND75S, ND94 printer

258 June 2004

28008103 PRT_PAPER_END Reason: The paper is used up completely. The residual paper is moved automatically out of the print path. Measure: Load new paper before next print job.

28008104 PRT_NO_MARK Reason: Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

28008105 PRT_RESET_ERROR_DRUM Reason: Reset switch on the drum is faulty, drive belt is faulty, stepper motor is faulty. Measure: Contact Customer Service.

28008106 PRT_RESET_ERROR_KNIFE Reason: The cutter is binding. Measure: The cutter did not reach one of the two end switches within a monitoring period. Cutter motor is faulty. Contact Customer Service.

28008107 PRT_TRANSPORT_ERROR Reason: Paper jam in paper path. Measure: Check paper path, sensor: Remove paper jam.

28008108 PRT_COLLECTING_TRAY_FULL Reason: Programming error: An attempt is made to feed more than 10 forms into the stacker. Measure: Inform system administrator.

Page 267: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND75, ND75S, ND94 printer

June 2004 259

28008109 PRT_OUTPUT_SLOT_OCCUPIED Reason: Programming error: the receipt(s)/form(s) were not removed before issuing a new print job. Application: The application must ensure, via the status job, that the removal stacker is free prior to a transport job. Measure: Transport of receipts/forms by means of the respective job or by pressing the respective button on the print unit.

2800810A PRT_FONT_SET_NOT_FOUND Reason: Access to a non-existent font module. Application: Select other character set Measure: Install font module

2800810B PRT_PAPER_STILL_IN_TONGS Reason: Forms in gripper after 2 reject attempts or customer removed forms during reject attempt. Static charge of the drum. The forms in the reject box are fanned up and jam transport. If customer has removed forms: undefined removal Application: "Reset form" job . If the error remains: see Measure; otherwise continue with the application. Measure: Check transport routes, remove any paper jam.

2800810C PRT_EXTERNAL_LIGHT Reason: External light when adjusting photosensor Open housing with strong external light (sun light). Measure: Close cover. Inform Customer Service if error occurs again.

Page 268: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND75, ND75S, ND94 printer

260 June 2004

2800810D PRT_ROCKER_KNIFE_DRUM_FAULT Reason: Rocker does not return to home position after cutting. The drum does not move any longer. The cutter cannot cut the paper. Measure: Contact Customer Service.

2800810E PRT_OUTPUT_SLOT_SHUTTER_FAULT Reason: Remove stacker door does not open or does not open completely. Door is binding (too much pressure on housing). Magnet faulty or connector for magnet not connected or loose. Measure: Check transport routes. Inform Customer Service if error occurs again.

2800810F PRT_COUNTERS_DEFAULT_SET Reason: Cheque counter in Backup RAM deleted Checksum error. Cheque counter is set on 0 (zero). Application: Set cheque counter new. Measure: If error occurs again check hardware and replace memory if required.

28008110 PRT_PRINT_CONTROL_ERROR Reason: Print control mark not found. Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, ribbon faulty/used up. Measure: Check paper guide and ribbon. Inform customer service if problem occurs again.

Page 269: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND75, ND75S, ND94 printer

June 2004 261

StWarn:

28000001 PRT_STACK_END Reason: Paper-low condition. Only a few forms are still available. Application: Complete transaction and output information for the operator. Measure: Load paper

28000002 PRT_WEEKEND_LIMIT Reason: Weekend limit reached. The paper stock is too low for several days. Application: Inform operator if required. Measure: Load paper

28000003 PRT_TENTH_DOCUMENT Reason: A form feed command caused a feed to the 1st line of the 10th document. Application: Output the contents of the collecting tray after the next form feed.

28000004 PRT_PRE_WARN_REJECT Reason: Message which indicates that the set limit for the reject box has been exceeded. Measure: Empty the reject box. Possibly increase capacity of reject box via software.

Page 270: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

262 June 2004

Page 271: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 263

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer StClass:

STCLASS_OK No error STCLASS_ERROR_ND97 Error of the CSCWND97.DLL

StCode:

20008009 PRT_FALSE_STATUS_LEN Reason: Error while transmitting the status buffer. Application: Check the length specification in the status command. Measure: The printer can send an invalid length, therefore check the printer hardware

20008100 PRT_NO_GRAPHIC Reason: The connected printer is not able to print into the graphic mode. Measure: Check the connected printer.

20008101 PRT_NO_MONITOR_MODE Reason: Programming error. The application tries to get a monitor message without starting the monitor. Application: Check the application.

20008102 PRT_MONITOR_RUNNING Reason: Programming error. The application tries to start the monitor, but the monitor is still running. Application: Check the application program.

Page 272: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

264 June 2004

20008103 PRT_MONITOR_WRONG_PROCESS Reason: Programming error. The application tries to stop the monitor or to get a monitor message with an other process as the monitor was started. Application: Check the application program.

28008102 PRT_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

28008103 PRT_PAPER_END Reason: The paper is used up completely. The residual paper is moved automatically out of the print path. Measure: Load new paper before next print job.

28008104 PRT_NO_MARK Reason: Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

28008105 PRT_RESET_ERROR_DRUM Reason: Drum cover not locked, reset switch on the drum is faulty, drive belt is faulty, stepper motor is faulty. Measure: Lock the drum cover. If error occurs agein, contact your Customer Service.

28008106 PRT_RESET_ERROR_KNIFE Reason: The cutter is binding. Measure: The cutter did not reach one of the two end switches within a monitoring period. Cutter motor is faulty. Contact Customer Service.

Page 273: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

June 2004 265

28008107 PRT_TRANSPORT_ERROR Reason: Paper jam in paper path. Measure: Check paper path, sensor: Remove paper jam.

28008108 PRT_COLLECTING_TRAY_FULL Reason: Programming error: An attempt is made to feed more than 10 documents into the stacker. Measure: Inform system administrator.

28008109 PRT_OUTPUT_SLOT_OCCUPIED Reason: Programming error: the document(s) were not removed before issuing a new print job. Application: The application must ensure, via the status job, that the removal stacker is free prior to a transport job. Measure: Transport of documents by means of the respective job or by pressing the respective button on the print unit.

2800810A PRT_FONT_SET_NOT_FOUND Reason: Access to a non-existent font module. Application: Select other character set Measure: Install font module

2800810B PRT_PAPER_STILL_IN_TONGS Reason: Document in gripper after 2 reject attempts Static charge of the drum. The documents in the reject box are fanned up and jam transport. Measure: Check transport routes, remove any paper jam.

Page 274: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

266 June 2004

2800810C PRT_EXTERNAL_LIGHT Reason: External light when adjusting photosensor Open housing with strong external light (sun light). Measure: Close cover. Inform Customer Service if error occurs again.

2800810D PRT_ROCKER_KNIFE_DRUM_FAULT Reason: Rocker does not return to home position after cutting. The drum does not move any longer. The cutter cannot cut the paper. Measure: Contact Customer Service.

2800810E PRT_OUTPUT_SLOT_SHUTTER_FAULT Reason: Remove stacker door does not open or does not open completely. Door is binding (too much pressure on housing). Magnet faulty or connector for magnet not connected or loose. Measure: Check transport routes. Inform Customer Service if error occurs again.

28008111 PRT_MORE_ERRORS Reason: Printer hardware error Application: Terminate applications requiring the printer. Call printer status. Measure: Check printer (self-test), if necessary inform service.

28008112 PRT_TO_MANY_REJECTS Reason: Message which indicates that the set limit for the reject box has been exceeded. Measure: Empty the reject box.

Page 275: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

June 2004 267

28008113 PRT_INTERN_SOFTWARE_ERROR Reason: The printer firmware receives an internal software error. Measure: Inform customer service if problem occurs again.

28008120 PRT_DRUM_COVER_NOT_CLOSED Reason: Drum cover not closed. This error occurs only in expanded mode. In the ND94 compatible mode, PRT_TRANSPORT_ERROR will be generated instead of this error. Measure: Close drum cover.

28008121 PRT_NO_PAPER_LANE Reason: Paper lane to be selected is not available. Measure: Check the appropriate printer paper lane.

28008122 PRT_PAPER_END_LANE2 Reason: The paper of paper lane 2 is used up completely. The residual paper has been removed automatically from the print path. Measure: Load new paper before starting next print job.

28008123 PRT_PRINT_CONTROL_ERROR Reason: Programming error: the printed documents had not been removed from the stacker before issuing a new paper lane-select job. Application: The application must ensure, that the removal stacker is free prior to a paper lane-select job. Measure: Transport of documents by means of the respective job.

Page 276: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

268 June 2004

28008124 PRT_GRAPHIC_ABORT Reason: A print job in the graphic mode was aborted, for example because the graphic data came too slowly. Application: Retry the graphic job; if error recurs: check the configuration of the system.

28008125 PRT_GRAPHIC_WRONG_COMMAND Reason: The printer sends an internal software error during a graphic print job. Application: Retry the graphic job. Measure: Inform customer service if problem occurs again.

StWarn:

20000001 PRT_PAPER_RETRACTED Reason: Automatically offered pages were not taken in the maximum offering time, therefore the printer retracted the pages automatically. Application: All pages of a transaction were not completely taken.

20000020 PRT_WEEKEND_LIMIT_OK_EVENT Reason: This warning is reserved for a special application: this event indicates that both paper lanes can be used without any restriction again. Application: Both paper lanes can be used again. Produce an appropriate application event.

20000021 PRT_WEEKEND_LIMIT_EVENT Reason: This warning is reserved for a special application: this event indicates that the sensor for weekend limit 1 and weekend limit 2 occurs. Application: Produce an appropriate application event.

Page 277: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

June 2004 269

20000022 PRT_PAPER_END_1_EVENT Reason: This warning is reserved for a special application: this event indicates that the weekend limit and paper end of paper lane 1 occurs and the printer has changed the current paper lane to paper lane 2. Application: Produce an appropriate application event.

20000023 PRT_PAPER_END_2_EVENT Reason: This warning is reserved for a special application: this event indicates that the weekend limit and paper end of paper lane 2 occurs and the printer has changed the current paper lane to paper lane 1. Application: Produce an appropriate application event.

20000024 PRT_PAPER_END_EVENT Reason: This warning is reserved for a special application: this event indicates that the paper end of paper lane 1 and the paper end of paper lane 2 occurs. Application: Produce an appropriate application event.

28000001 PRT_STACK_END Reason: Paper-low condition. Only a few documents are still available. Application: Complete transaction and output information for the operator. Measure: Load paper

28000002 PRT_WEEKEND_LIMIT Reason: Weekend limit reached. The paper stock is too low for several days. Application: Inform operator if required. Measure: Load paper

Page 278: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

270 June 2004

28000003 PRT_TENTH_DOCUMENT Reason: A form feed command caused a feed to the 1st line of the 10th document. Application: Output the contents of the collecting tray after the next form feed.

28000004 PRT_PRE_WARN_REJECT Reason: Message which indicates that the set limit for the reject box has been exceeded. Measure: Empty the reject box. Possibly increase capacity of reject box via software.

28000005 PRT_CONTRAST_OK Reason: A previously insufficient print contrast measurement is now ready again.

28000006 PRT_WEAK_CONTRAST Reason: The print contrast measurement detected weak printing. The printing is weak, but still readable. Measure: Check printer ribbon cartridge. Replace the linked ribbon if necessary.

28000007 PRT_NO_SUFFICIENT_CONTRAST Reason: The print contrast measurement detected very weak printing. Measure: Replace the printer ribbon cartridge.

28000008 PRT_STACK_END_LANE2 Reason: Paper-low condition of paper lane 2. Only a few documents are still available. Application: Complete transaction and prompt the operator. Measure: Load paper in lane 2.

Page 279: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97, TH97, TP01, NP01, TP05, NP05, TP09 printer

June 2004 271

28000009 PRT_WEEKEND_LIMIT_LANE2 Reason: Weekend limit of paper lane 2 reached. The paper stock is too low for several days. Application: Inform operator if required. Measure: Load paper in paper lane 2.

2800000A PRT_CHECKSUM_MEMORY Reason: Checksum error of the internal parameters memory. Printer uses default parameters. Application: Load new parameters, if necessary. Inform customer service if the problem occurs again.

Page 280: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

272 June 2004

Page 281: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 273

ND97 firmware loader (LDR3) StClass:

STCLASS_OK No error STCLASS_ERROR_LDR3 Error of the CSCWLDR3.DLL

StCode:

20008000 LDR3_LOAD_SEM_TIMEOUT Reason: A process cannot use the loader because another process is still using the loader. Measure: Reboot the system. If the error occurs again report this error log to Service.

20008001 LDR3_INI_FILE_OPEN_FAILED Reason: Cannot open the control file PP.INI. Measure: Check the file PP.INI.

20008002 LDR3_INI_FILE_READ_ERROR Reason: Cannot read the control file PP.INI. Measure: Check the file PP.INI.

20008003 LDR3_INVALID_FILE Reason: Checksum of a file to be loaded is not correct. Measure: The file is probably corrupted. Check the file.

Page 282: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND97 firmware loader (LDR3)

274 June 2004

20008004 LDR3_FILE_ACCESS_ERROR Reason: Cannot read the file to be loaded. Measure: Check the file.

20008005 LDR3_INVALID_MODID Reason: File to be loaded has invalid modul-id. Measure: Check the file.

20008006 LDR3_FRM_LOADER_NOT_READY Reason: The expected response of the Firmware Loader is not correct. Application: Repeat the last API-function to start the download process again. If the error occurs again report this error log to Service.

20008007 LDR3_INVALID_LOADED_FILE Reason: Downloaded file data do not reach the firmware controller correctly. Application: Repeat the last API-function to start the download process again. If the error occurs again report this error log to Service.

Page 283: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 275

ND99 printer StClass:

STCLASS_OK No error STCLASS_ERROR_ND99 Error of the CSCWND99.DLL

StCode:

2000810D PRT_FRM_FILE_MOD Reason: The firmware HEX-file SWC728.HEX has no valid firmware version. Measure: Check the firmware HEX-file.

2000810E PRT_INVALID_FIRMWARE_FILE Reason: Recognized a faulty firmware load file "SWC728.HEX" by the try to load the firmware. Measure: Check the firmware download file.

20008110 PRT_WRONG_FIRMWARE_LOADED Reason: The loaded printer firmware has a release smaller than 0305. Application: Load a valid printer firmware with a release greater or equal to 0305 by using the API function "CscPrtInit".

28008100 PRT_PRESENTER_ERR Reason: Hardware error receipt presenter module. Measure: Check printer hardware (presenter hardware), if necessary remove paper jam.

Page 284: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND99 printer

276 June 2004

28008101 PRT_TOF_ERR Reason: Printer cannot recognize a top-of-form mark. Measure: Check the hardware or the paper.

28008102 PRT_HEAD_LIFTED Reason: The print head is lifted. Measure: Check the hardware and if necessary take the head in the print position.

28008103 PRT_FORMAT_LOGO Reason: Syntax error in the ESCAPE sequence for loading LOGO. Application: Transfer correct LOGO format.

28008104 PRT_PARITY Reason: A parity error is returned from the printer when faulty characters are received. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008105 PRT_HARDWARE_ERR Reason: A hardware error occurred at power ON (self-test). Measure: Check the hardware.

28008106 PRT_POWER_LOST Reason: Short-term power failed on during operation. Application: The printer works with the default character parameters. If necessary, repeat the print. Measure: Check the hardware. Inform Customer Service if error occurs again.

Page 285: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND99 printer

June 2004 277

28008107 PRT_BON_PAPER_END Reason: Paper-out condition. The current form is still printed. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam.

28008108 PRT_SOFTWARE_ERR Reason: Trying to select non-existing user-defined character fonts. Application: Check the user-defined character fonts and check the application program.

28008109 PRT_BUFF_OVERFLOW Reason: The printer buffer is overflow. Application: Program error, check application program.

2800810A PRT_CMD_REC Reason: Loss of command. The command was sent and could not be correctly executed. Application: Repeat the command. Check the application program if error occurs again.

2800810B PRT_CUTTER Reason: Cutter not in home position. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor), remove paper jam.

Page 286: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND99 printer

278 June 2004

2800810C PRT_FORMAT_CHAR Reason: Syntax error in the ESCAPE sequence for loading user-defined characters. Application: Transfer correct character set format.

2800810F PRT_NO_FIRMWARE_LOADED Reason: No firmware is loaded or the download firmware is faulty. Application: Start the command "load firmware" to load the current firmware.

Page 287: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND99 printer

June 2004 279

StWarn:

20000002 PRT_WARN_NO_FIRMWARE_FILE Reason: The API function "CscPrtOpen" check the validity of the firmware load file "SWC728.HEX". This warning occur, if a faulty firmware load file was found or if the firmware load file cannot find. The environment variable <CSCROOT>\FRM defines the location of the firmware file. When <CSCROOT> is not set, the file must be located in the CSC\FRM directory. Measure: Check the firmware file.

20000003 PRT_WARN_NO_ACTUAL_FIRMWARE Reason: The firmware on the disk is different than the software currently loaded in the printer. Application: If necessary load the firmware by using the API function "CscPrtInit". Measure: Check the firmware HEX-file.

20000004 PRT_WARN_NO_FIRMWARE_LOADED Reason: There is no firmware loaded or the download firmware is faulty. This warning can only occur by the API function "CscPrtOpen". Application: Load the firmware by using the API function "CscPrtInit".

20000005 PRT_WARN_WRONG_FIRMWARE_LOADED Reason: The loaded printer firmware has a release smaller than 0305. Application: Load a valid printer firmware with a release greater or equal to 0305 by using the API function "CscPrtInit".

Page 288: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

ND99 printer

280 June 2004

28000001 PRT_WARN_BON_PAPER_LOW Reason: "Receipt paper low" warning. The device only contains the preset quantity of receipts. Application: Inform operator to load paper. Measure: The next time the CSC is maintained, the paper supply for receipts should be replenished.

Page 289: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 281

TH21 printer StClass:

STCLASS_OK No error STCLASS_ERROR_TH21 Error of the CSCWTH21.DLL

StCode:

20008120 TH21_COMMUNICATION_ERROR Reason: Communication error with monitor module when the monitor functionality is used. Measure: Check monitor module configuration.

20008121 TH21_NO_DRIVER_FOUND Reason: No GDI driver "WN_TH21" found (when using the monitor functionality). Measure: Check driver configuration.

20008122 TH21_INVALID_PORT Reason: Invalid COM port entry for the GDI driver (when using the monitor functionality). Values from COM1 to COMx are allowed. Measure: Check driver configuration.

20008201 TH21_INI_FILE_OPEN_FAILED Reason: Cannot open the control file TH21.INI in the appropriate directory. Measure: Check the control file TH21.INI.

Page 290: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TH21 printer

282 June 2004

20008202 TH21_INI_FILE_READ_ERROR Reason: Cannot read the control file TH21.INI. Measure: Check the control file TH21.INI.

20008203 TH21_INVALID_FILE Reason: Cannot open a file or invalid file name give up. Measure: Check the valid of the file.

20008204 TH21_FILE_ACCESS_ERROR Reason: Printer hardware error. Cannot read the file to be loaded. Measure: Check the file.

20008205 TH21_INVALID_MODID Reason: File to be loaded has an invalid module id. Measure: Check the file.

20008206 TH21_FRM_LOADER_NOT_READY Reason: The expected response of the Firmware Loader is not correct, Application: Repeat the last API-function to start the download process again. If the error occurs again report this error log to Service.

20008207 TH21_INVALID_LOADED_FILE Reason: Invalid logo type by the loading of a logo for the printer TH21 or logo file is too big. Measure: Check the valid of the logo file for the printer TH21.

Page 291: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TH21 printer

June 2004 283

20008208 TH21_SERVER_ERROR Reason: Loading system error while the print systen was being invoked. This error aborted the connection to the print system. Measure: Check the system error code in the error log.

20008209 TH21_LM_WRITE_ERROR Reason: A print system WRITE command could not be executed in the specified monitoring time. Measure: Check the hardware if necessary.

2000820A TH21_LM_READ_ERROR Reason: A print system READ command could not be executed in the specified monitoring time. Measure: Check the hardware if necessary.

28008100 TH21_PAPER_END Reason: Paper-out condition. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor).

28008101 TH21_COVER Reason: The cover is properly opened. Application: Inform operator to close the cover. Measure: Close the cover; if necessary check printer disconnecting cover-switch.

Page 292: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TH21 printer

284 June 2004

28008102 TH21_PRINT_HEAD Reason: The print head temperature is not ok. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008103 TH21_POWER_LOST Reason: Short-term power failed on during operation. Application: If necessary, repeat the print. Measure: Check the hardware. Inform Customer Service if error occurs again.

28008104 TH21_PAPER_JAM Reason: Receipt paper jam. Receipt could not be correctly processed. Measure: Check paper feed.

28008105 TH21_CUTTER Reason: The cutter is binding. Measure: The cutter did not reach one of the two end switches within a monitoring period. Cutter motor is faulty. Contact Customer Service.

28008106 TH21_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

Page 293: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TH21 printer

June 2004 285

StWarn:

28000001 TH21_WARN_BON_PAPER_LOW Reason: "Receipt paper low" warning. The device only contains the preset quantity of receipts. Application: Inform operator to load paper. Measure: The next time the CSC is maintained, the paper supply for receipts should be replenished.

Page 294: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

286 June 2004

Page 295: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 287

HPEM printer StClass:

STCLASS_OK No error STCLASS_ERROR_HPEM Error of the CSCWHPEM.DLL

StCode:

20008112 PRT_INVALID_MSGID Reason: Device Handler get invalid Command ID. Measure: Check printer, if necessary inform service.

20008200 HPEM_PROTOCAL_TX_TIMEOUT Reason: The total protocol monitoring time during transmission has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008201 HPEM_PROTOCOL_RX_TIMEOUT Reason: The total protocol monitoring time during receive has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 296: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

HPEM printer

288 June 2004

20008202 HPEM_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid (only ACK, NAK and STX are valid). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

28008100 PRT_NO_PAPER Reason: No passbook inserted. Application: Respond as required by application. The printer need a reset command (API function CscPrtInit).

28008102 PRT_DATA_TRANSMISSION_ERROR Reason: Error during communication with printer. Data format error or protocol error. Application: The printer need a reset command (API function CscPrtInit).

28008103 PRT_MAGNETIC_STRIPE_ERROR Reason: Magnetic stripe read or write error. Measure: Check the passbook.

28008105 PRT_HARDWARE_ERR Reason: Detection of a hardware error. Application: Check printer status (SPEC: PRT_HPEM_ERROR). If necessary send a reset command by using the API function "CscPrtInit'" (see also BH1800 Series Passbook Entry Machine: Error Codes & Error Processing Specifications). Measure: Check the hardware.

Page 297: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

HPEM printer

June 2004 289

28008106 PRT_POWER_LOST Reason: Power failed on during operation (printer switch off/on). Application: The printer works with the default character parameters. If necessary, repeat the print. Measure: Call customer service.

2800810B PRT_NO_PAPER_ACCEPT Reason: Inserted passbook was not accepted by printer. Application: Respond as required by application.

2800810F PRT_SWITCH Reason: Detects a printer cover-open state. Measure: Close cover, if necessary check sensor.

28008110 PRT_PAPER_TRAY Reason: Customer did not remove passbook from output slot or there is still a document in the print unit. Application: Move document into reject box.

28008111 PRT_MORE_ERRORS Reason: Printer error Application: The printer has an error. Check printer status (SPEC: PRT:HPEM_ERROR). If necessary send a reset command by using the API function "CscPrtInit".

Page 298: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

290 June 2004

Page 299: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 291

PRTX Printer messages StClass:

STCLASS_OK No error STCLASS_ERROR_PRTX Error of the CSCWPRTX.DLL

StCode:

20008000 PRTX_SYSTEM_ERROR Reason: A system error has occurred. Measure: Check the system error code in the error log.

20008001 PRTX_SERVER_ERROR Reason: Print system error while the print systen was being invoked. This error aborted the connection to the print system. Application: Open the print system again. Check the application program if required.

20008002 PRTX_NOT_CONNECTED Reason: The application attempted to access the print system although there was no connection to the print system any more. Print system execution may have been aborted. Application: Open the print system again. Check the application program where necessary.

20008003 PRTX_ACCESS_TIMEOUT Reason: Open the print system again. Check the application program where necessary. Application: Repeat the job. Check the application program.

Page 300: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

PRTX Printer messages

292 June 2004

20008004 PRTX_GET_NOTIFICATION_CANCELLED Reason: A running "GetNotification" monitor job was aborted. Application: This is a status information message.

20008005 PRTX_SERVICE_ERROR Reason: An eccor occurred when the print system was started from the CSC service. Application: The CSC service must be closed and started again. Check the system where necessary.

Page 301: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 293

Print System Framework StClass:

STCLASS_OK No error STCLASS_ERROR_LMFRAME Error in the print system framework LMFRAME.DLL

StCode:

E0420001 LM_INSUFFICIENT_BUFFER Reason: The data area assigned to a call of the print system is too small. Application: Increase buffer size.

E0420002 LM_INVALID_REGISTRY_PARAMETER Reason: Invalid registry parameter. Measure: Check the registry parameter. See the log entry for the parameter name

E0420003 LM_INVALID_FUNCTION Reason: The requested operation is not valid or not supported by the printer. Application: Check the application program.

E0420004 LM_INTERNAL_ERROR Reason: Internal software error. Measure: Generate a trace of this error by means of the trace system and send trace and error log to the customer service center.

Page 302: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Print System Framework

294 June 2004

E0420005 LM_FUNCTION_NOT_ALLOWED Reason: Function not allowed in the current context. Application: Check application.

E0420006 LM_WRITE_ERROR Reason: Communication error. A write request was not successful. Measure: Check communication to the device. Check connection configuration.

E0420007 LM_SYSTEM_ERROR Reason: A system error occurred. Measure: See the system error code in the error log.

E0420008 LM_UNEXPECTED_PARAMETER Reason: Unexpected parameter in function call. Measure: Generate a trace of this error by means of the trace system and send trace and error log to the customer service center.

E0420009 LM_OPEN_ERROR Reason: Open failed. Measure: See port name and printer name in the errror log. Check also the system error code in the error log. Check spooler configuration for the printer and its associated port.

E042000A LM_JOB_START_FAILED Reason: Start of a print job failed. Measure: Check the system error code in the error log. Check spooler configuration for the printer and its associated port.

Page 303: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Print System Framework

June 2004 295

E042000B LM_PORT_BUSY Reason: A job has been despooled while another job is still in progress. Measure: Generate a trace of this error by means of the trace system and send trace and error log to the customer service center.

E042000D LM_SRV_INVALID_PARAMETER Reason: Invalid parameter used in a server function call. Application: Check client application.

E042000E LM_SRV_ALREADY_REGISTERED Reason: Client already registered for monitoring. Application: Check client application.

E042000F LM_SRV_ALREADY_CLAIMED Reason: The client tried to claim the device twice. Application: Check client application.

E0420010 LM_SRV_INVALID_CLIENT_HANDLE Reason: Invalid client handle used. Application: Check client application.

E0420011 LM_SRV_NOT_REGISTERED Reason: Client not registered for monitoring. Application: Change application.

Page 304: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Print System Framework

296 June 2004

E0420012 LM_SRV_START Reason: Start of print system server failed. Measure: Check system error code in error log.

E0420013 LM_SRV_PRINTER_NOT_FOUND Reason: Connection failed. The printer is unknown. Measure: Check configuration especially the printer name.

E0420014 LM_SRV_ACCESS_DENIED Reason: Access denied. Client is not allowed to perform the requested operation. Application: Check application. Note that special operations are only allowed according to the open specification.

E0420015 LM_SRV_ACCESS_LOCKED Reason: Access is denied because another client has claimed the device for exclusive access. Measure: No action required.

E0420016 LM_UNKNOWN_PROPERTY Reason: Unknown property. Application: Change application. See the error log for the name of the unknown property.

E0420017 LM_PROPERTY_FORMAT_ERROR Reason: The property has an invalid format. Application: Change application.

Page 305: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Print System Framework

June 2004 297

E0420018 LM_INVALID_PROPERTY Reason: The property value is invalid. Application: Change application.

E0420019 LM_INVALID_STRING Reason: An invalid input string has been supplied. Application: Change application.

Page 306: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

298 June 2004

Page 307: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 299

LDND9G - Loader for printer ND9G StClass:

STCLASS_OK No error STCLASS_ERROR_LDND9G Error of the LDND9G.DLL

StCode:

20008000 LDND9G_INVALID_FILE Reason: Cannot open a file or checksum of a file to be loaded is not correct. Measure: The file is probably corrupted. Check the file.

20008001 LDND9G_FILE_ACCESS_ERROR Reason: Cannot read the firmware file to be loaded. Measure: Check the firmware file.

20008002 LDND9G_INVALID_MODID Reason: Cannot read the file to be loaded. Measure: Check the file.

20008003 LDND9G_FRM_LOADER_NOT_READY Reason: The expected response of the Firmware Loader is not correct. Application: Repeat the loading process again. If the error occurs again report this error log to Service.

Page 308: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LDND9G - Loader for printer ND9G

300 June 2004

20008004 LDND9G_INVALID_LOADED_FILE Reason: Firmware file data do not reach the firmware controller correctly. Application: Repeat the loading process again. If the error occurs again report this error log to Service.

20008005 LDND9G_SERVER_ERROR Reason: An error occurred when the print system was started from the CSC service. Application: The CSC service must be closed and started again. Check the system where necessary.

StWarn:

20000001 LDND9G_WARN_FILE_CTR Reason: The value of the Registry entry "FILE_CTR" cross the maximum value of loadable firmware files ( ND9G = 1 ). Measure: Check and correct the Registry entry "FILE_CTR".

20000002 LDND9G_WARN_FILE_NR Reason: No entry "FILE1" found in the Registry. Measure: Check the Registry entry "FILE1".

Page 309: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 301

LMND9G Printer Monitor StClass:

STCLASS_OK No error STCLASS_ERROR_LMND9G Error of the LMND9G.DLL

StCode:

E0400001 LMND9G_PAPER_END Reason: Paper-out condition. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor).

E0400002 LMND9G_DEVICE Reason: Terminate applications requiring the printer. Measure: Check printer (self-test), if necessary inform service.

E0400003 LMND9G_JAM Reason: Receipt paper jam. Receipt could not be correctly processed. Measure: Check paper feed.

Page 310: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMND9G Printer Monitor

302 June 2004

E0400004 LMND9G_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

E0400005 LMND9G_CMD Reason: Printer detect unexpected data. Application: Repeat the command if necessary.

E0400006 LMND9G_PARITY Reason: A parity error is returned from the printer when faulty characters are received. Measure: Check the hardware. Inform Customer Service if error occurs again.

E0400007 LMND9G_CMD_LOST Reason: Loss of a command. The command was sent and could not be correctly executed. Application: Repeat the command if necessary.

E0400009 LMND9G_MARK Reason: By activated mark, recognition a mark is not found. Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

E040000A LMND9G_CHECKSUM Reason: A checksum error of the RAM is occurred. Measure: Hardware error. Inform Customer Service.

Page 311: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMND9G Printer Monitor

June 2004 303

E040000B LMND9G_FW Reason: The loaded firmware file does not fit to the printer hardware. Application: Check the firmware file.

E040000D LMND9G_INVALID_DATA Reason: Unexpected data was received. Application: Repeat the command if necessary.

E040000E LMND9G_WRITE_TIMEOUT Reason: A WRITE command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E040000F LMND9G_READ_TIMEOUT Reason: A READ command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E0400010 LMND9G_WAIT_FOR_NEXT_JOB Reason: This message may only occur when controlled print jobs (C jobs) are received. After a received print job had been executed, no further control command (e.g. eject) was received within the monitoring time. Application: Check application.

Page 312: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMND9G Printer Monitor

304 June 2004

E0400011 LMND9G_LINE_PARAMETER Reason: An error occurred while the required line parameters were being set. Measure: Check the hardware. Inform Customer Service if error occurs again.

E0400012 LMND9G_INT_ERROR Reason: An internal SW error occurred. Measure: Inform Customer Service.

Page 313: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 305

LMTH21 Printer Monitor StClass:

STCLASS_OK No error STCLASS_ERROR_LMTH21 Error of the LMTH21.DLL

StCode:

E0410001 LMTH21_PAPER_END Reason: Paper-out condition. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor).

E0410002 LMTH21_COVER Reason: The cover is properly opened. Application: Inform operator to close the cover. Measure: Close the cover; if necessary check printer disconnecting cover-switch.

E0410003 LMTH21_HEAD Reason: The print head temperature is not ok. Measure: Check the hardware. Inform Customer Service if error occurs again.

Page 314: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH21 Printer Monitor

306 June 2004

E0410004 LMTH21_VOLTAGE Reason: Short-term power failed during operation or insufficient power supply. Application: If necessary, repeat the print. Measure: Check the hardware. Inform Customer Service if error occurs again.

E0410005 LMTH21_JAM Reason: Receipt paper jam. Receipt could not be correctly processed. Measure: Check paper feed.

E0410006 LMTH21_CUTTER Reason: The cutter is binding. Measure: The cutter did not reach one of the two end switches within a monitoring period. Cutter motor is faulty. Contact Customer Service.

E0410007 LMTH21_MEMORY Reason: Hardware error: error in memory test (RAM and ROM), backup RAM faulty. Measure: Check hardware and replace memory if required.

E0410008 LMTH21_INVALID_DATA Reason: Unexpected data was received. Application: Repeat the command if necessary.

Page 315: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH21 Printer Monitor

June 2004 307

E0410009 LMTH21_WRITE_TIMEOUT Reason: A WRITE command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E041000A LMTH21_READ_TIMEOUT Reason: A READ command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E041000B LMTH21_WAIT_FOR_NEXT_JOB Reason: This message may only occur when controlled print jobs (C jobs) are received. After a received print job had been executed, no further control command (e.g. eject) was received within the monitoring time. Application: Check application.

E041000C LMTH21_LINE_PARAMETER Reason: An error occurred while the required line parameters were being set. Measure: Check the hardware. Inform Customer Service if error occurs again.

E041000D LMTH21_MARK Reason: By activated mark, recognition a mark is not found. Paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

Page 316: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

308 June 2004

Page 317: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 309

LDTH5X Firmware Loader StClass:

STCLASS_OK No error STCLASS_ERROR_LDTH5X Error detected in LDTH5X.DLL

StCode:

E0470001 LDTH5X_SECTION_NOT_FOUND Reason: The registry does not contain a CSCPRT section where the printer name matches the name of the printer to be loaded. Measure: Adjust configuration. Note that the printer name which is specified for CscService has to match exactly the name given in the CSCPRT section.

E0470002 LDTH5X_FW_FILE_NOT_SPECIFIED Reason: Name of the firmware file not specified. Measure: Adjust configuration and specify firmware file.

E0470003 LDTH5X_CANNOT_OPEN_FRM_FILE Reason: The specified firmware file could not be opened. Measure: Check configuration. If t the firmware file is correctly specified and present then check the logged system error.

E0470004 LDTH5X_INVALID_FW_FILE Reason: Invalid firmware file. Measure: Check configuration. If neccessary get a valid firmware file.

Page 318: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LDTH5X Firmware Loader

310 June 2004

E0470005 LDTH5X_INVALID_FW_ID Reason: The printer reported an unknown firmware id. Measure: Send error report to customer service.

E0470006 LDTH5X_CANNOT_OPEN_PRINTER Reason: Printer could not be opened. Measure: Check configuration. If the configuration is correct then send an error report to customer service.

E0470007 LDTH5X_CANNOT_CLAIM_PRINTER Reason: It was not possible to communicate with the printer because it was busy. Measure: Restart the system.

E0470008 LDTH5X_NO_MEMORY Reason: The operating system could not provide sufficient memory. Measure: Check memory configuration.

E0470015 LDTH5X_NOT_CONNECTED Reason: The printer is switched off or not connected to the system (offline). Measure: Check printer, printer cable and connections.

E0470016 LDTH5X_INVALID_DATA Reason: Invalid data has been received. Measure: Check printer cable and connections.

Page 319: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LDTH5X Firmware Loader

June 2004 311

E0470017 LDTH5X_WRITE_FAULT Reason: There was a communication error during a data transfer to the printer (write operation). Measure: Check printer cable and connections.

E0470018 LDTH5X_READ_FAULT Reason: There was a communication error during a data transfer from the printer (read operation). Measure: Check printer cable and connections.

E0470019 LDTH5X_READ_TIMEOUT Reason: The printer did not respond to a request during an adequate time frame. Measure: Check printer cable and connections.

Page 320: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

312 June 2004

Page 321: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 313

LMTH5X Printer Monitor StClass:

STCLASS_OK No error STCLASS_ERROR_LMTH5X Error detected in LMTH5X.DLL

StCode:

E0460001 LMTH5X_PAPER_END Reason: Paper-out condition or paper not loaded. Application: It is not possible to print. Measure: Operator intervention required: Load paper.

E0460002 LMTH5X_PAPER_INIT_REQUIRED Reason: Paper path could not be initialized due to a wrong paper position. Application: It is not possible to print. Measure: Operator intervention required: Remove paper completely from the paper path and load paper again.

E0460003 LMTH5X_PAPER_JAM Reason: There was a paper jam. Application: It is not possible to print. Measure: Operator intervention required: Remedy the jam, remove the paper from the paper path, and load paper again.

Page 322: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH5X Printer Monitor

314 June 2004

E0460005 LMTH5X_MARK_NOT_FOUND Reason: Printer could not find the black mark. Application: It is not possible to print. Measure: Operator intervention required: Remove paper from paper path. Check paper, black marks and paper path. Check paper rollwhether it operates only sluggishly. Load paper again with the black marks at the bottom of the paper.

E0460006 LMTH5X_WRONG_MARK_POSITION Reason: Printer could not detect the black mark at the expected location. Application: It is not possible to print. Measure: Operator intervention required: Remove paper from paper path. Check paper, black marks and paper path. Check paper roll whether it operates only sluggishly. Load paper again with the black marks at the bottom of the paper.

E0460007 LMTH5X_MAX_LENGTH_EXCEEDING Reason: The form that has been selected for the current print job is longer than the loaded one. Application: It is not possible to print. If necessary check the way the application selects the paper form. Measure: Operator intervention required: Remove paper from paper path and load paper again. Check also the default printing settings whether the form setting matches the loaded form.

E046000A LMTH5X_CUTTER_OPEN Reason: Cutter/printing unit is open or not locked. Application: It is not possible to print. Measure: Operator intervention required: Lock the cutter and printing unit by pressing down on the positions marked accordingly on the left and right sides of the unit.

Page 323: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH5X Printer Monitor

June 2004 315

E046000D LMTH5X_CUTTER_ERROR Reason: Cutter error occurred. Application: It is not possible to print. Measure: Operator intervention required: Check cutter unit and paper path.

E046000E LMTH5X_WRONG_CUTTER_POSITION Reason: During initialization the cutter was not in the right position. Either an operator has left the printer in this state or the printer has a cutter problem. Application: If possible, retry print job. Measure: The print system will try to recover from this error with the next print job. If the next print job again fails with this error an operator intervention is required: Check cutter unit and paper path.

E0460011 LMTH5X_JOB_CANCELLED Reason: A print job has been cancelled by an application. Application: This error only occurs as a result of an application request. Measure: No measure required.

E0460012 LMTH5X_DRAWOFF_TIMEOUT Reason: The draw-off monitoring time has been exceeded. This is the time the print system waits for a printed page to be drawn off by the dispenser. Application: Use the dispenser to eject or to retract the printed page. The printed page can also be removed for disposal by means of a reset command to the dispenser. Measure: Check application. Check also the printer configuration because there is a specific configuration parameter which specifies the length of this time frame. If necessary, this time value has to be increased and the system to be restarted afterwards.

Page 324: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH5X Printer Monitor

316 June 2004

E0460013 LMTH5X_PRINT_TIMEOUT Reason: The printer did not print a page within a given time. Application: If possible, retry print job. Measure: The print system will try to recover from this error with the next print job. Check printer cable and connections.

E0460015 LMTH5X_NOT_CONNECTED Reason: The printer is switched off or not connected to the system (offline). Application: It is not possible to print as long as the printer is offline. Measure: Check printer, printer cable and connections.

E0460016 LMTH5X_INVALID_DATA Reason: Invalid data has been received. Application: This error sets the printer state to offline. It is not possible to print as long as the printer is offline. Measure: Check printer cable and connections.

E0460017 LMTH5X_WRITE_FAULT Reason: There was a communication error during a data transfer to the printer (write operation). Application: This error sets the printer state to offline. It is not possible to print as long as the printer is offline. Measure: Check printer cable and connections.

Page 325: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTH5X Printer Monitor

June 2004 317

E0460018 LMTH5X_READ_FAULT Reason: There was a communication error during a data transfer from the printer (read operation). Application: This error sets the printer state to offline. It is not possible to print as long as the printer is offline. Measure: Check printer cable and connections.

E0460019 LMTH5X_READ_TIMEOUT Reason: The printer did not respond to a request during a given time frame. Application: This error sets the printer state to offline. It is not possible to print as long as the printer is offline. Measure: Check printer cable and connections.

E046001E LMTH5X_FRM_ERROR Reason: An unexpected printer error occurred. Application: If possible, retry print job. Measure: Send error report to customer service.

E046001F LMTH5X_INVALID_COMMAND Reason: An unexpected error occurred during communication with the device. Application: If possible, retry print job. Measure: Send error report to customer service.

Page 326: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

318 June 2004

Page 327: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 319

LMTP07 Printer Monitor StClass:

STCLASS_OK No error STCLASS_ERROR_LMTP07 Error of the LMTP07.DLL

StCode:

E0440001 LMTP07_PAPER_END Reason: Paper-out condition. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor).

E0440002 LMTP07_CUTTER_JAM Reason: Paper jam while cutting the paper. Measure: Check paper guide. Inform customer service if problem occurs again.

E0440003 LMTP07_MARK Reason: By activated mark, recognition a mark is not found. Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

Page 328: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTP07 Printer Monitor

320 June 2004

E0440004 LMTP07_PRESENTER_JAM Reason: Paper jam after the cutting of a receipt in the presenter. The receipt could not be correctly processed. Measure: Check paper guide. Inform customer service if problem occurs again.

E0440005 LMTP07_RETRACTOR_JAM Reason: Paper jam after the cutting of a receipt while a reject command. The receipt could not be correctly processed. Measure: Check paper guide. Inform customer service if problem occurs again.

E0440006 LMTP07_JAM Reason: Receipt paper jam while the printing process. The receipt could not be correctly processed. Measure: Papierführung überprüfen. Bei wiederholtem Auftreten den TKD benachrichtigen.

E0440007 LMTP07_JOB_TIMEOUT Reason: An internal print job timeout is occurred. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E0440008 LMTP07_HIGH_VOLTAGE Reason: The power voltage of the printer is too high. Measure: Hardware error. Inform Customer Service.

Page 329: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTP07 Printer Monitor

June 2004 321

E0440009 LMTP07_LOW_VOLTAGE Reason: The power voltage of the printer is too low. Measure: Hardware error. Inform Customer Service.

E044000A LMTP07_HEAD Reason: The temperature of the print head is too high. Measure: Hardware error. Inform Customer Service.

E044000B LMTP07_TYPE Reason: Hardware error. Measure: Hardware error. Inform Customer Service.

E0440010 LMTP07_INVALID_DATA Reason: Unexpected data was received. Application: Repeat the command if necessary.

E0440011 LMTP07_WRITE_TIMEOUT Reason: A WRITE command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 330: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

LMTP07 Printer Monitor

322 June 2004

E0440012 LMTP07_READ_TIMEOUT Reason: A READ command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

E0440013 LMTP07_WAIT_FOR_NEXT_JOB Reason: This message may only occur when controlled print jobs (C jobs) are received. After a received print job had been executed, no further control command (e.g. eject) was received within the monitoring time. Application: Check application.

E0440015 LMTP07_INT_ERROR Reason: An internal SW error occurred. Measure: Inform customer service.

E0440016 LMTP07_OFFLINE_ERROR Reason: The printer is in the offline state without any specific device error. Application: Try to initialize the printer. Measure: Inform customer service if error occurs again.

Page 331: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 323

RJ03 Printers StClass:

STCLASS_OK No error STCLASS_ERROR_R03 Receipt printer error of the CSCWRJ03.DLL STCLASS_ERROR_J03 Journal printer error of the CSCWRJ03.DLL

StCode:

20008100 RJ03_INVALID_RESPONSE Reason: Unexpected data was received. Application: Repeat the command if necessary.

20008101 RJ03_MALLOC_ERROR Reason: Allocation error. Not enough resources to allocate internal memory. Measure: Check the system.

20008102 RJ03_READ_TIMEOUT Reason: A READ command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 332: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

RJ03 Printers

324 June 2004

20008103 RJ03_CODE_PAGE Reason: Code page not available. Application: Choose an alternate code page.

20008104 RJ03_INVALID_FILE Reason: Cannot open a image file or invalid file name give up. Measure: Check the valid of the file.

20008105 RJ03_FILE_ACCESS_ERROR Reason: Cannot read the file to be loaded. Measure: Check the valid of the file.

20008106 RJ03_INVALID_LOADED_FILE Reason: Invalid logo type by the loading of a logo for the printer or logo file is too big. Measure: Check the system error code in the error log.

20008107 RJ03_OFFLINE Reason: The printer is in the offline state without any specific device error. Application: Try to initialize the printer. Measure: Inform Customer Service if error occurs again.

Page 333: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

RJ03 Printers

June 2004 325

20008108 RJ03_NO_DEVICE Reason: There are no devices of the specified type available or the USB device has been removed from the system. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

28008000 RJ03_PAPER_END Reason: Paper-out condition. Application: If the application cannot run without receipt output, it must be terminated, otherwise no specific reactions are required. Measure: Load paper, if necessary check printer hardware (paper feeder, sensor).

28008001 RJ03_CUTTER_JAM Reason: Paper jam while cutting the paper. Measure: Check paper guide. Inform customer service if problem occurs again.

28008002 RJ03_HOME_POSITION Reason: The carrier don't found the home position (only impact printer). Measure: Check paper guide. Inform customer service if problem occurs again.

28008003 RJ03_CARRIER_JAM Reason: Paper jam before cutting. Measure: Check paper guide. Inform customer service if problem occurs again.

Page 334: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

RJ03 Printers

326 June 2004

28008004 RJ03_MARK Reason: By activated mark, recognition a mark is not found. Paper jam, paper skew, bad/missing mark on paper, dirty/faulty photosensor, loaded paper does not meet paper specification. Measure: Check paper guide. Inform customer service if problem occurs again.

28008005 RJ03_PRESENTER_JAM Reason: Paper jam after the cutting of a receipt in the presenter. The receipt could not be correctly processed. Measure: Check paper guide. Inform customer service if problem occurs again.

28008006 RJ03_RETRACTOR_JAM Reason: Paper jam after the cutting of a receipt while a reject command. The receipt could not be correctly processed. Measure: Check paper guide. Inform customer service if problem occurs again.

28008007 RJ03_JAM Reason: Receipt paper jam while the printing process. The receipt could not be correctly processed. Measure: Check paper guide. Inform customer service if problem occurs again.

28008008 RJ03_HIGH_VOLTAGE Reason: The power voltage of the printer is too high. Measure: Hardware error. Inform Customer Service.

28008009 RJ03_LOW_VOLTAGE Reason: The power voltage of the printer is too low. Measure: Hardware error. Inform Customer Service.

Page 335: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

RJ03 Printers

June 2004 327

2800800A RJ03_HEAD Reason: The temperature of the print head is too high. Measure: Hardware error. Inform Customer Service.

2800800B RJ03_TYPE Reason: Hardware error. Measure: Hardware error. Inform Customer Service.

2800800C RJ03_OP_AFTER_POWER_ON_ERR Reason: The paper is not at the print starting position after power-on an error is generated (if the concerning memory switch is activated). Measure: Remove the printed receipt.

2800800D RJ03_NO_PAPER_MOTION Reason: The paper of a journal printer was not transported while a print out command. Paper jam occurred or paper end was reached. Measure: Check paper guide. Load paper, if necessary.

StWarn:

28000001 RJ03_WARN_BON_PAPER_LOW Reason: "Paper low" warning. The device only contains the preset quantity of paper. Application: Inform operator to load paper. Measure: The next time the System is maintained, the paper supply for receipts or journals should be replenished.

Page 336: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

328 June 2004

Page 337: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 329

SB500 scanner (S500) StClass:

STCLASS_OK No error STCLASS_ERROR_S500 Error of the CSCWS500.DLL

StCode:

20008000 S500_INVALID_PARA Reason: Invalid parameter. Measure: Software error, inform service.

20008001 S500_NO_DOCUMENT Reason: No document inserted. Application: Respond as required by application.

20008002 S500_MICR_NOT_SELECTED Reason: Function CscPrtRead was called, but no MICR mode via CscPrtControl selected. Application: Check application program. Inform Customer Service if error occurs again. Measure: Software error, inform service.

Page 338: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

330 June 2004

20009001 S500_SERVER_SYS_ERR Reason: The service was unable to execute command due to a system error. Memory allocation error. Measure: Software error, inform service.

20009002 S500_SCSI_ERR Reason: The service was unable to execute command due to a SCSI error. Error condition coming from SCSI Manager or SCSI adapter. Application: Call Software Reset (CscPrtInit / Spec. RESERVED). Inform Customer Service if error occurs again.

20009003 S500_PERIF_NOT_FOUND Reason: Peripheral not found by the service. Peripheral is switched off or not connected to the SCSI bus. Measure: Check the hardware. Inform Customer Service if error occurs again.

20009004 S500_HARD_ERR Reason: Peripheral hardware error. Measure: Check the hardware. Inform Customer Service if error occurs again.

20009005 S500_PERIF_OFF_ON Reason: The peripheral has been switched off and on again between the last and the current command. Application: Retry command. Measure: Check the hardware. Inform Customer Service if error occurs again.

Page 339: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

June 2004 331

20009006 S500_RESERV_ERR Reason: Another program is using the peripheral. Application: Retry command. Call Customer Service if error occurs again.

20009007 S500_BOURRAGE Reason: Document jammed. Application: Call Function Reset and free (CscPrtInit / Spec. RESET_FREE). Inform Customer Service if error occurs again. Measure: Check the hardware.

20009008 S500_DOC_FEED_ERR Reason: Document feeding error. Measure: Check the hardware. Inform Customer Service if error occurs again.

20009009 S500_INVALID_CMD Reason: The current command contains invalid parameters specification or is inconsistent with the previous command sequence. Application: Check application program. Inform Customer Service if error occurs again.

2000900A S500_DATA_LOST Reason: Error during SCSI data transfer. SCSI command terminated with data overrun/underrun error. Application: Check application program. Inform Customer Service if error occurs again.

Page 340: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

332 June 2004

2000900B S500_EXEC_CMD Reason: The current command is in execution and an other command has been launched. Application: Check application program. Inform Customer Service if error occurs again.

2000900C S500_JPEG_ERROR Reason: JPEG image not created. The current command is inconsistent with the command sequence. Application: Check application program. Inform Customer Service if error occurs again.

2000900D S500_CMD_SEQUENCE_ERROR Reason: The command's sequence is not correct. Application: Check application program. Inform Customer Service if error occurs again.

2000900E S500_NOT_USED Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

2000900F S500_INVALID_HANDLE Reason: Internal Firmware error. The handle is invalid. Application: Check application program. Inform Customer Service if error occurs again.

20009010 S500_OPEN_NOT_DONE Reason: Internal Firmware error. Perform a commad without previous open. Application: Check application program. Inform Customer Service if error occurs again.

Page 341: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

June 2004 333

20009011 S500_NO_LIBRARY_LOAD Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

20009012 S500_RESOLUTON_NOT_SUPPORTED Reason: Internal Firmware error. Provide to a function a resolution not supported. Application: Check application program. Inform Customer Service if error occurs again.

20009013 S500_ILLEGAL_MOVEMENT Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

20009014 S500_PERIPHERAL_TIMEOUT Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

20009015 S500_BMP_ERROR Reason: Internal Firmware error. Error on saving BMP file. Application: Check application program. Inform Customer Service if error occurs again.

20009016 S500_TIFF_ERROR Reason: Internal Firmware error. Error on saving TIFF file. Application: Check application program. Inform Customer Service if error occurs again.

Page 342: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

334 June 2004

20009017 S500_MISSING_IMAGE Reason: Internal Firmware error. Handle of image is not provided to a function that requires it. Application: Check application program. Inform Customer Service if error occurs again.

20009018 S500_INVALID_TYPE Reason: Internal Firmware error. Invalid format for TIFF files. Application: Check application program. Inform Customer Service if error occurs again.

20009019 S500_INVALID_SAVEMODE Reason: Internal Firmware error. Invalid parameters for TIFF files. Application: Check application program. Inform Customer Service if error occurs again.

2000901A S500_INVALID_PAGE_NUMBER Reason: Internal Firmware error. Invalid parameters for TIFF files. Application: Check application program. Inform Customer Service if error occurs again.

2000901B S500_INVALID_TYPE_COMMAND Reason: Internal Firmware error. Type of command invalid. Application: Check application program. Inform Customer Service if error occurs again.

2000901C S500_INVALID_STEP Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

Page 343: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

June 2004 335

2000901D S500_INVALID_DOC_HANDLING Reason: Internal Firmware error. Invalid parameter DocHandling in DocHandle functions. Application: Check application program. Inform Customer Service if error occurs again.

2000901E S500_INVALID_DRAWER Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

20009064 S500_PERIPHERAL_NOT_ANSWER Reason: Internal Firmware error. Time-out on the wait event occurs. Application: Check application program. Inform Customer Service if error occurs again.

20009102 S500_DATATRUNC Reason: Internal Firmware error. Data transferred during command execution has been truncated because the destination buffer was too small. Application: Check application program. Inform Customer Service if error occurs again.

20009104 S500_ALREADY_OPEN Reason: Internal Firmware error. The peripheral is already connected. Application: Check application program. Inform Customer Service if error occurs again.

20009108 S500_NO_ENDCMD Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

Page 344: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

336 June 2004

2000910A S500_NOSENSE Reason: Internal Firmware error. The peripheral is busy. Application: Check application program. Inform Customer Service if error occurs again.

2000910C S500_TARGETBUSY Reason: Internal Firmware error. The peripheral is busy or a command is already in execution. Application: Check application program. Inform Customer Service if error occurs again.

2000910D S500_TRY_TO_RESET Reason: Internal Firmware error. The peripheral is in error. Application: Try to execute a Reset command.

2000910F S500_STRINGTRUNCATED Reason: Internal Firmware error. Application: Check application program. Inform Customer Service if error occurs again.

20009201 S500_IMACON_ERROR_SYNTAX Reason: Illegal arguments calling IMACON.DLL. Application: Check application program. Inform Customer Service if error occurs again.

20009202 S500_IMACON_ERROR_INPUT_OPEN Reason: Cannot open input file. Application: Check application program. Inform Customer Service if error occurs again.

Page 345: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

June 2004 337

20009203 S500_IMACON_ERROR_INPUT_READ Reason: Error reading input. Application: Check application program. Inform Customer Service if error occurs again.

20009204 S500_IMACON_ERROR_OUTPUT_OPEN Reason: Cannot open output file. Application: Check application program. Inform Customer Service if error occurs again.

20009205 S500_IMACON_ERROR_OUTPUT_WRITE Reason: Error writing output file. Application: Check application program. Inform Customer Service if error occurs again.

20009206 S500_IMACON_ERROR_MEMORY Reason: Not enough memory. Application: Check application program. Inform Customer Service if error occurs again.

20009207 S500_IMACON_ERROR_TOO_LONG Reason: Image too long. Application: Check application program. Inform Customer Service if error occurs again.

20009208 S500_IMACON_ERROR_TOO_LARGE Reason: Image too large (for TIF). Application: Check application program. Inform Customer Service if error occurs again.

Page 346: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

SB500 scanner (S500)

338 June 2004

20009209 S500_IMACON_ERROR_TOO_SMALL Reason: Image too small (<1 row). Application: Check application program. Inform Customer Service if error occurs again.

200092FF S500_IMACON_UNDEF_ERROR Reason: IMACON.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

Page 347: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 339

CM3000 scanner (CM3K) StClass:

STCLASS_OK No error STCLASS_ERROR_CM3K Error of the CSCWCM3K.DLL

StCode:

20008000 CM3K_INVALID_PARA Reason: Invalid parameter. Measure: Software error, inform service.

20008001 CM3K_NO_DOCUMENT Reason: No document inserted. Application: Respond are required by application.

20008002 CM3K_MICR_NOT_SELECTED Reason: Function CscPrtRead was calls, but no MICR mode via CscPrtControl selected, Application: Check application program. Inform Customer Service if error occurs again. Measure: Software error, inform service.

20008006 CM3K_ERROR_OPEN_RAW_FILE Reason: Cannot open raw file (CM3K.RAW). Application: Check application program. Inform Customer Service if error occurs again.

Page 348: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

340 June 2004

20008007 CM3K_ERROR_WRITE_FILE Reason: Error writing raw file (CM3K.RAW). Application: Check application program. Inform Customer Service if error occurs again.

20008008 CM3K_ERROR_SHUTTER_OPEN Reason: The external shutter could not be opened. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008009 CM3K_ERROR_SHUTTER_CLOSE Reason: The external shutter could not be closed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008100 CM3K_ERROR_INIT Reason: The initialization of the scanner failed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008101 CM3K_ERROR_TIMEOUT_FW Reason: Time out by waiting of return from firmware command. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

Page 349: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 341

20008110 CM3K_PAPER_TRAY Reason: There is still a document in the scanner. Application: Move document to the reject box. Measure: Check the hardware if necessary.

20008200 CM3K_INVALID_FIRMWARE_FILE Reason: The firmware file(s) is/are invalid. More than one version of a firmware file is in the directory. Measure: Check the <CSCROOT>\FRM directory.

20008201 CM3K_ERROR_LOAD_FIRMWARE Reason: Error while loading the firmware file(s). Measure: Check the hardware if necessary.

20009001 CM3K_ERROR_BADSETUP Reason: Invalid options or parameter. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20009002 CM3K_ERROR_FEEDEREMPTY Reason: The document feeder is empty. Application: Repeat the command if necessary.

Page 350: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

342 June 2004

20009003 CM3K_ERROR_DOCINTRACK Reason: A document is still in track. Application: Repeat the command if necessary.

20009004 CM3K_ERROR_ALREADYACTIVE Reason: The scanner can not be started, because it is currently active running a document or transferring image data from the scanner. Application: Repeat the command if necessary. Measure: Check the hardware.

20009005 CM3K_ERROR_DISABLED Reason: Scanning is disabled by the API because of incompatible firmware version. Application: Repeat the command if necessary. Measure: Check the hardware. Inform service.

20009006 CM3K_ERROR_FEEDERJAM Reason: Feeder failed to start document. Application: Repeat the command if necessary. Measure: Check the hardware.

Page 351: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 343

20009007 CM3K_ERROR_TRACKWATCHDOG Reason: Time-out while document transport. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20009008 CM3K_ERROR_CANT_RECOVER Reason: The document position not permit to try a recover. Application: Retry command.

2000900A CM3K_ERROR_JAM Reason: A document is stuck or lost in track.. Application: Retry command. Measure: Check the hardware.

2000900B CM3K_ERROR_TIMEOUT Reason: Time-out by waiting for codeline. Application: Repeat the command if necessary. Measure: Check the hardware.

2000900C CM3K_ERROR_DOUBLE Reason: Double feed. Application: Repeat the command if necessary. Measure: Check the hardware.

Page 352: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

344 June 2004

2000900D CM3K_ERROR_FILEWRITE Reason: Problem writing image file. Application: Repeat the command if necessary. Measure: Check the hardware. Disk full.

2000900E CM3K_ERROR_SCSI Reason: SCSI error reported by ASPI during an interaction with the CM3000. Application: Repeat the command if necessary. Measure: Check the hardware.

2000900F CM3K_ERROR_IMAGECALLBACK Reason: an image processing callback routine reports an error (internal error). Application: Repeat the command if necessary. Measure: Check the hardware.

20009010 CM3K_ERROR_INTERNAL Reason: CM3API internal error. Application: Repeat the command if necessary. Measure: Reboot if necessary.

Page 353: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 345

20009011 CM3K_ERROR_UNKNOWN Reason: CM3API internal error. Application: Repeat the command if necessary. Measure: Check the hardware.

20009012 CM3K_ERROR_ALLOCBIN Reason: Memory allocation failed. Application: Repeat the command if necessary.

20009013 CM3K_ERROR_G4ENCODE Reason: The G4 compression routine reports an error (CM3API internal error). Application: Repeat the command if necessary.

20009014 CM3K_ERROR_NODOKUMENTDATA Reason: a tracking error for the CM3000 is reported for the last document. No image data or codeline data are available. Application: Rescan the document. Repeat the command if necessary. Measure: Check the hardware.

20009015 CM3K_ERROR_TREATMENT Reason: CM3API internal error. Application: Repeat the command if necessary. Measure: Check the hardware.

Page 354: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

346 June 2004

20009016 CM3K_ERROR_DOCLONGFOROP Reason: Document is too long for the selected operation. Application: Repeat the command if necessary. Measure: Check the hardware.

20009017 CM3K_ERROR_OCRHEADPROBLEM Reason: A hardware problem is reported by the OCR read head. Application: Repeat the command if necessary. Measure: Check the hardware.

20009018 CM3K_ERROR_BADDEVICE Reason: An attempt was made to use a device option which is not present. Application: Repeat the command if necessary. Measure: Check the hardware.

20009019 CM3K_ERROR_EXTSHUTTER Reason: Opening or closing the external shutter failed. Application: Repeat the command if necessary. Measure: Check the hardware.

Page 355: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 347

2000901A CM3K_ERROR_INTSHUTTER Reason: Opening or closing the internal shutter failed. Application: Repeat the command if necessary. Measure: Check the hardware.

2000901B CM3K_ERROR_METALDETECTOR Reason: The document have a staple. Application: Repeat the command if necessary. Measure: Check the document.

2000901C CM3K_ERROR_RIBBONCART Reason: Ribbon cartridge is missing. Application: Repeat the command if necessary. Measure: Check the hardware.

2000901D CM3K_ERROR_WRONG_TRACKCOMM Reason: The scanner can´t do the command required. Application: Repeat the command if necessary. Measure: Check the hardware.

Page 356: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

348 June 2004

2000901E CM3K_ERROR_WRONG_EJECT Reason: CM3API.DLL internal error. Application: Repeat the command if necessary. Measure: Check the hardware.

200090FF CM3K_ERROR_UNDEF Reason: CM3API.DLL returned undefined error. Application: Check application program. Inform customer Service if error occurs again.

20009201 CM3K_IMACON_ERROR_SYNTAX Reason: Illegal arguments calling IMACON.DLL. Application: Check application program. Inform Customer Service if error occurs again.

20009202 CM3K_IMACON_ERROR_INPUT_OPEN Reason: Cannot open input file. Application: Check application program. Inform Customer Service if error occurs again.

20009203 CM3K_IMACON_ERROR_INPUT_READ Reason: Error reading input. Application: Check application program. Inform Customer Service if error occurs again.

20009204 CM3K_IMACON_ERROR_OUTPUT_OPEN Reason: Cannot open output file. Application: Check application program. Inform Customer Service if error occurs again.

Page 357: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 349

20009205 CM3K_IMACON_ERROR_OUTPUT_WRITE Reason: Error writing output file. Application: Check application program. Inform Customer Service if error occurs again.

20009206 CM3K_IMACON_ERROR_MEMORY Reason: Not enough memory. Application: Check application program. Inform Customer Service if error occurs again.

20009207 CM3K_IMACON_ERROR_TOO_LONG Reason: Image too long. Application: Check application program. Inform Customer Service if error occurs again.

20009208 CM3K_IMACON_ERROR_TOO_LARGE Reason: Image too large (for TIF). Application: Check application program. Inform Customer Service if error occurs again.

20009209 CM3K_IMACON_ERROR_TOO_SMALL Reason: Image too small (<1 row). Application: Check application program. Inform Customer Service if error occurs again.

200092FF CM3K_IMACON_UNDEF_ERROR Reason: IMACON.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

Page 358: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

350 June 2004

20009300 CM3K_DQF_ERR_ILLEGAL_PARAM Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009301 CM3K_DQF_ERR_NO_MEMORY Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009302 CM3K_DQF_ERR_HGHLOW_INVALID Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009303 CM3K_DQF_ERR_LOWEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009304 CM3K_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009305 CM3K_DQF_ERR_SENSITIVNESS_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

Page 359: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CM3000 scanner (CM3K)

June 2004 351

200093FF CM3K_DQF_UNDEF_ERROR Reason: DQF.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

Page 360: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

352 June 2004

Page 361: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 353

TOSCA scanner (TSC) StClass:

STCLASS_OK No error STCLASS_ERROR_TSC Error of the CSCWTSC.DLL

StCode:

20008000 TSC_INVALID_PARA Reason: Invalid parameter. Measure: Software error, inform service.

20008001 TSC_NO_DOCUMENT Reason: No document inserted. Application: Respond are required by application.

20008004 TSC_INVALID_RXDATA Reason: The received acknowledge is invalid. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 362: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

354 June 2004

20008005 TSC_READ_TIMEOUT Reason: A command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008006 TSC_ERROR_OPEN_RAW_FILE Reason: Cannot open raw file (TSC.RAW). Application: Check application program. Inform Customer Service if error occurs again.

20008007 TSC_ERROR_WRITE_RAW_FILE Reason: Error writing raw file (TSC.RAW). Application: Check application program. Inform Customer Service if error occurs again.

20008018 TSC_ERROR_SHUTTER_OPEN Reason: The shutter could not be opened. Application: Retry command. Call Customer Service if error occurs again. Measure: Check the hardware if necessary.

20008019 TSC_ERROR_SHUTTER_CLOSE Reason: The shutter could not be closed. Application: Retry command. Call Customer Service if error occurs again. Measure: Check the hardware if necessary.

Page 363: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

June 2004 355

20009001 TSC_ERROR_CMD Reason: Communication problem or an invalid data packet is sent to the scanner. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20009003 TSC_ERROR_EJECT Reason: No document in the scanner (Command Eject). Application: Respond as required by application.

20009004 TSC_ERROR_TIMEOUT Reason: Time-out when processing an internal command. This could refer to a hardware error (paper jam), an oversized form or a user holding the form. Measure: Check the hardware. Inform Customer Service if error occurs again.

20009005 TSC_ERROR_MISSING_FORM Reason: No document in the scanner. Application: Respond as required by application.

20009006 TSC_ERROR_SCANNER Reason: An document longer than the specified length was detected. Application: Respond as required by application.

Page 364: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

356 June 2004

20009007 TSC_ERROR_BUSY Reason: The scanner is executing a command. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20009008 TSC_SERIAL_ERROR Reason: The hardware already has a programmed serial number (internal error). Measure: Inform Customer Service if error occurs again.

20009009 TSC_ERROR_SHUTTER Reason: The shutter is blocked or defective. Application: Retry command. Call Customer Service if error occurs again.

2000900A TSC_ERROR_CCD Reason: Error while reading data from scanhead EE-PROM. Application: Repeat the command if necessary.

2000900B TSC_ERROR_LS Reason: During startup, the functions of all photosensors are verified. Warning: If there is a document in the scanner during startup, all covered photosensors are reported as defective. Application: Repeat the command if necessary.

Page 365: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

June 2004 357

2000900D TSC_STARTUP_OCCURED Reason: A startup of the scanner has occurred. Application: Repeat the command if necessary.

20009201 TSC_IMACON_ERROR_SYNTAX Reason: Illegal arguments calling IMACON.DLL. Application: Check application program. Inform Customer Service if error occurs again.

20009202 TSC_IMACON_ERROR_INPUT_OPEN Reason: Cannot open input file. Application: Check application program. Inform Customer Service if error occurs again.

20009203 TSC_IMACON_ERROR_INPUT_READ Reason: Error reading input. Application: Check application program. Inform Customer Service if error occurs again.

20009204 TSC_IMACON_ERROR_OUTPUT_OPEN Reason: Cannot open output file. Application: Check application program. Inform Customer Service if error occurs again.

20009205 TSC_IMACON_ERROR_OUTPUT_WRITE Reason: Error writing output file. Application: Check application program. Inform Customer Service if error occurs again.

Page 366: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

358 June 2004

20009206 TSC_IMACON_ERROR_MEMORY Reason: Not enough memory. Application: Check application program. Inform Customer Service if error occurs again.

20009207 TSC_IMACON_ERROR_TOO_LONG Reason: Image too long. Application: Check application program. Inform Customer Service if error occurs again.

20009208 TSC_IMACON_ERROR_TOO_LARGE Reason: Image too large (for TIF). Application: Check application program. Inform Customer Service if error occurs again.

20009209 TSC_IMACON_ERROR_TOO_SMALL Reason: Image too small (<1 row). Application: Check application program. Inform Customer Service if error occurs again.

200092FF TSC_IMACON_UNDEF_ERROR Reason: IMACON.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

20009300 TSC_DQF_ERR_ILLEGAL_PARAM Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

Page 367: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

TOSCA scanner (TSC)

June 2004 359

20009301 TSC_DQF_ERR_NO_MEMORY Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009302 TSC_DQF_ERR_HGHLOW_INVALID Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009303 TSC_DQF_ERR_LOWEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009304 TSC_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

20009305 TSC_DQF_ERR_SENSITIVNESS_RANGE Reason: Internal error while calling DQF.DLL. Application: Inform Customer Service if error occurs again.

200093FF TSC_DQF_UNDEF_ERROR Reason: DQF.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

Page 368: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

360 June 2004

Page 369: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 361

Scanner software RecoStar (RECO) StClass:

STCLASS_OK No error STCLASS_ERROR_RECO Error of the CSCWRECO.DLL

StCode:

20008000 RECO_NO_DONGLE Reason: Wrong RecoStar software installed. Application: Abort the current transaction. Measure: Check the RecoStar software.

20008001 RECO_SET_ERROR_FKT Reason: The error function cannot be initialised (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20008002 RECO_NO_RECOSTAR_MODUL Reason: RecoStar software module ai*.dll not found in appropriate path. Application: Abort the current transaction. Measure: Check the RecoStar software module ai*.dll in the appropriate CSC-W32 path.

Page 370: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

362 June 2004

20008003 RECO_NO_CTRL_FILE Reason: No control file with extension (*.cla. *.lex or *.par) found in the appropriate path. Application: Abort the current transaction. Measure: Check the control files in the appropriate CSC-W32 path.

20008004 RECO_NOT_ONE_CTRL_FILE Reason: More than one control file with same extension (*.cla. *.lex or *.par) found in the appropriate path. Application: Abort the current transaction. Measure: Check the control files.

20008005 RECO_CTRL_FILE_OPEN_ERROR Reason: Cannot open a control file. Application: Abort the current transaction. Measure: Check the control files.

20008006 RECO_CTRL_FILE_READ_ERROR Reason: Cannot read a control file. Application: Abort the current transaction. Measure: Check the control files.

Page 371: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 363

20008007 RECO_INIT_TIFF_FKT_ERROR Reason: The TIFF functions cannot be initialised (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20008008 RECO_OPEN_TIFF_FILE Reason: Cannot open internal image file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20008009 RECO_MEMORY_TIFF_FILE Reason: Not enough memory for internal image file. Application: Abort the current transaction. Measure: Check the system resources.

2000800A RECO_INVALID_FORM Reason: The form size of a scanned document is invalid. Application: Abort the current transaction. Measure: Check the form.

Page 372: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

364 June 2004

20010400 RECO_LGK_ERROR_04 Reason: Error on initializing the LGK functions (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010500 RECO_LGK_ERROR_05 Reason: LGK function not allowed in current status (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010800 RECO_LGK_ERROR_08 Reason: The RecoStar-DLL could not be opened. Application: Abort the current transaction. Measure: Check the RecoStar-DLL ai*.dll in the appropriate path.

20010900 RECO_LGK_ERROR_09 Reason: Error in the configuration string of Lc_open(). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 373: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 365

20010A00 RECO_LGK_ERROR_0A Reason: Error on opening the start file for pagination (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010B00 RECO_LGK_ERROR_0B Reason: Error on opening the HSI log file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010C00 RECO_LGK_ERROR_0C Reason: Error on initializing the HSI log file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010D00 RECO_LGK_ERROR_0D Reason: Error on opening a download SW file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 374: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

366 June 2004

20010E00 RECO_LGK_ERROR_0E Reason: Error on opening a parameter file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20010F00 RECO_LGK_ERROR_0F Reason: Error on opening the classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011000 RECO_LGK_ERROR_10 Reason: Error on opening the dictionary file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011100 RECO_LGK_ERROR_11 Reason: Error on writing the dictionary file 1 (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 375: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 367

20011200 RECO_LGK_ERROR_12 Reason: Error on writing the dictionary file 2 (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011300 RECO_LGK_ERROR_13 Reason: Error on closing the device (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011400 RECO_LGK_ERROR_14 Reason: Error Lc_GetData(): no data structure transferred (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011500 RECO_LGK_ERROR_15 Reason: Error on reading image/read data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 376: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

368 June 2004

20011600 RECO_LGK_ERROR_16 Reason: Error on editing read data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011700 RECO_LGK_ERROR_17 Reason: Error in the classifier description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011800 RECO_LGK_ERROR_18 Reason: Error in the parameter description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011900 RECO_LGK_ERROR_19 Reason: Error in BS order description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 377: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 369

20011A00 RECO_LGK_ERROR_1A Reason: Error in image parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011B00 RECO_LGK_ERROR_1B Reason: Realloc() error further read data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011C00 RECO_LGK_ERROR_1C Reason: Read data error: too large or wrong data type (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011D00 RECO_LGK_ERROR_1D Reason: Error Lc_GetData(): no mode set (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 378: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

370 June 2004

20011E00 RECO_LGK_ERROR_1E Reason: Document data error: not defined data type (internal error), Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20011F00 RECO_LGK_ERROR_1F Reason: Warning: check sum error in dictionary data found (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012000 RECO_LGK_ERROR_20 Reason: Error in configuration data from the device: wrong length. Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012100 RECO_LGK_ERROR_21 Reason: Error: insufficient memory for complete image (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 379: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 371

20012200 RECO_LGK_ERROR_22 Reason: Error: wrong call for set mode (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012300 RECO_LGK_ERROR_23 Reason: Error: unknown option (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012400 RECO_LGK_ERROR_24 Reason: Error on opening the file with changed parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012500 RECO_LGK_ERROR_25 Reason: Error in BK order description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 380: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

372 June 2004

20012600 RECO_LGK_ERROR_26 Reason: Error on opening the update file (filter, ...). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012700 RECO_LGK_ERROR_27 Reason: Error in update order description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012800 RECO_LGK_ERROR_28 Reason: Invalid filter type (internal error.) Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012900 RECO_LGK_ERROR_29 Reason: Error on opening the file with printer parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 381: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 373

20012A00 RECO_LGK_ERROR_2A Reason: Error in PP order description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012B00 RECO_LGK_ERROR_2B Reason: Error on opening the file with stacker parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012C00 RECO_LGK_ERROR_2C Reason: Error in BA order description structure (location). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012D00 RECO_LGK_ERROR_2D Reason: No licence for RecoStar found (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 382: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

374 June 2004

20012E00 RECO_LGK_ERROR_2E Reason: RecoStar licence not correct for this version (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20012F00 RECO_LGK_ERROR_2F Reason: RecoStar licence has terminated (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20013000 RECO_LGK_ERROR_30 Reason: No access to RecoStar licence (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20013200 RECO_LGK_ERROR_32 Reason: hsi_order error: HSI order length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 383: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 375

20013C00 RECO_LGK_ERROR_3C Reason: loadmem error: length of the data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20013D00 RECO_LGK_ERROR_3D Reason: loadmem error: wrong length Statement in HSI order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20014600 RECO_LGK_ERROR_46 Reason: hsi_response error: order length of the response data too small (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20014700 RECO_LGK_ERROR_47 Reason: hsi_response error: order length of the response data too large (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 384: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

376 June 2004

20014800 RECO_LGK_ERROR_48 Reason: hsi_response error: malloc() memory for response data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20014900 RECO_LGK_ERROR_49 Reason: hsi_response error: malloc() memory for response data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015000 RECO_LGK_ERROR_50 Reason: Loadfile error: position (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015200 RECO_LGK_ERROR_52 Reason: Loadfile error: length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 385: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 377

20015400 RECO_LGK_ERROR_54 Reason: Loadfile error: read header (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015500 RECO_LGK_ERROR_55 Reason: Loadfile error: order length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015700 RECO_LGK_ERROR_57 Reason: Loadfile error: read order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015900 RECO_LGK_ERROR_59 Reason: Loadfile error: malloc() memory for order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 386: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

378 June 2004

20015A00 RECO_LGK_ERROR_5A Reason: Loadfile error: read order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20015C00 RECO_LGK_ERROR_5C Reason: Loadfile error: malloc() memory for order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200250F2 RECO_ERROR_50_F2 Reason: WIBU-Key error while decoding program parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200250F3 RECO_ERROR_50_F3 Reason: DD command not supported (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 387: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 379

200250F7 RECO_ERROR_50_F7 Reason: No licence found for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025101 RECO_ERROR_51_01 Reason: Parameter error signalled for a document description (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025102 RECO_ERROR_51_02 Reason: Image without valid parameters (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025103 RECO_ERROR_51_03 Reason: Too many read areas defined in a document description (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 388: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

380 June 2004

20025105 RECO_ERROR_51_05 Reason: Missing document description (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025108 RECO_ERROR_51_08 Reason: An unknown document type was found in a document description (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200251F1 RECO_ERROR_51_F1 Reason: Too many partial dictionaries (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200251F2 RECO_ERROR_51_F2 Reason: In document description dictionary mode not supported (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 389: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 381

200251F3 RECO_ERROR_51_F3 Reason: In document description dictionary mode not allowed (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200251F4 RECO_ERROR_51_F4 Reason: In document description dictionary not available (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200251F5 RECO_ERROR_51_F5 Reason: In document description trigram table not available (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025201 RECO_ERROR_52_01 Reason: Download error: software not executable (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 390: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

382 June 2004

20025211 RECO_ERROR_52_11 Reason: Error while creating or registering the command (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025212 RECO_ERROR_52_12 Reason: Too many classifiers loaded (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025213 RECO_ERROR_52_13 Reason: Invalid memory size value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025214 RECO_ERROR_52_14 Reason: Program FB_INIT_ACCESS: command returns an error code (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 391: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 383

20025215 RECO_ERROR_52_15 Reason: Program FB_ADD_FORM: command returns an error code (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025218 RECO_ERROR_52_18 Reason: PC order must be preceded by a PA order (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025219 RECO_ERROR_52_19 Reason: Command not allowed in actual context (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025302 RECO_ERROR_53_02 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 392: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

384 June 2004

20025303 RECO_ERROR_53_03 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025304 RECO_ERROR_53_04 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025305 RECO_ERROR_53_05 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025306 RECO_ERROR_53_06 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 393: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 385

20025307 RECO_ERROR_53_07 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025308 RECO_ERROR_53_08 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025309 RECO_ERROR_53_09 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002530A RECO_ERROR_53_0A Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 394: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

386 June 2004

2002530D RECO_ERROR_53_0D Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025311 RECO_ERROR_53_11 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025312 RECO_ERROR_53_12 Reason: DK command: insufficient work space for classifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025313 RECO_ERROR_53_13 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 395: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 387

20025314 RECO_ERROR_53_14 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025315 RECO_ERROR_53_15 Reason: DK command: damaged classifier file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025501 RECO_ERROR_55_01 Reason: Undefined read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025502 RECO_ERROR_55_02 Reason: Undefined coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 396: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

388 June 2004

20025503 RECO_ERROR_55_03 Reason: Access error to a parameter of read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025504 RECO_ERROR_55_04 Reason: Access error to a parameter of coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025505 RECO_ERROR_55_05 Reason: Access error to a measurement mark of coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025506 RECO_ERROR_55_06 Reason: Self-referring read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 397: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 389

20025507 RECO_ERROR_55_07 Reason: Self-referring coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025508 RECO_ERROR_55_08 Reason: Too many measurement marks in coordinate system (max. 15 allowed). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025511 RECO_ERROR_55_11 Reason: Document description: TAG is missing (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025512 RECO_ERROR_55_12 Reason: Document description: TAG is multiple defined (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 398: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

390 June 2004

20025513 RECO_ERROR_55_13 Reason: Document description: TAG is of illegal data type or value range (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025514 RECO_ERROR_55_14 Reason: Document description: TAG has an illegal value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025515 RECO_ERROR_55_15 Reason: Document description: TAG has an illegal length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025519 RECO_ERROR_55_19 Reason: Document description: access error to a TAG (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 399: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 391

2002551A RECO_ERROR_55_1A Reason: Document description: reference to undefined read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002551B RECO_ERROR_55_1B Reason: Document description: reference to undefined document type (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025521 RECO_ERROR_55_21 Reason: Document description: TAG of a read area is missing (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025522 RECO_ERROR_55_22 Reason: Document description: TAG of a read area is multiple defined (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 400: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

392 June 2004

20025523 RECO_ERROR_55_23 Reason: Document description: TAG of a read area is illegal data type or value range (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025524 RECO_ERROR_55_24 Reason: Document description: TAG of a read area has a illegal value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025526 RECO_ERROR_55_26 Reason: Document description: multiple defined read area number (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025529 RECO_ERROR_55_29 Reason: Document description: access error to TAG of a read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 401: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 393

2002552A RECO_ERROR_55_2A Reason: Document description: reference to undefined read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002552C RECO_ERROR_55_2C Reason: Document description: reference to undefined character set (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002552D RECO_ERROR_55_2D Reason: Document description: reference to undefined coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025531 RECO_ERROR_55_31 Reason: Document description: TAG of a coordinate system missing (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 402: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

394 June 2004

20025532 RECO_ERROR_55_32 Reason: Document description: TAG of a coordinate system is multiple defined (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025533 RECO_ERROR_55_33 Reason: Document description: TAG of a coordinate system is illegal data type or value range (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025534 RECO_ERROR_55_34 Reason: Document description: TAG of a coordinate system has an illegal value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025536 RECO_ERROR_55_36 Reason: Document description: multiple defined coordinate system (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 403: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 395

20025539 RECO_ERROR_55_39 Reason: Document description: TAG of a coordinate system access error (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002553A RECO_ERROR_55_3A Reason: Document description: reference to undefined measurement marks (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025541 RECO_ERROR_55_41 Reason: Document description: TAG of a document type is missing (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025542 RECO_ERROR_55_42 Reason: Document description: TAG of a document type is multiple defined (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 404: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

396 June 2004

20025543 RECO_ERROR_55_43 Reason: Document description: TAG of a document type is of illegal data type or value range (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025544 RECO_ERROR_55_44 Reason: Document description: TAG of a document type has an illegal value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025545 RECO_ERROR_55_45 Reason: Document description: TAG of a document type has an illegal length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025546 RECO_ERROR_55_46 Reason: Document description: document type has multiple defined document type number (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 405: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 397

20025549 RECO_ERROR_55_49 Reason: Document description: document type access error to TAG (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002554A RECO_ERROR_55_4A Reason: Document description: document type reference to undefined read area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025551 RECO_ERROR_55_51 Reason: Document description: TAG of a character set is missing (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025552 RECO_ERROR_55_52 Reason: Document description: TAG of a character set is multiple defined (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 406: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

398 June 2004

20025553 RECO_ERROR_55_53 Reason: Document description: TAG of a character set is illegal data type or value range (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025554 RECO_ERROR_55_54 Reason: Document description: TAG of a character set has an illegal value (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025555 RECO_ERROR_55_55 Reason: Document description: TAG of a character set has an illegal length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025556 RECO_ERROR_55_56 Reason: Document description: character set has multiple defined character set number (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 407: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 399

20025559 RECO_ERROR_55_59 Reason: Document description: character set access error to TAG (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200255F1 RECO_ERROR_55_F1 Reason: Access error to snippet list (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200255F2 RECO_ERROR_55_F2 Reason: Access error to the descriptor of snippet number xx (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

200255F3 RECO_ERROR_55_F3 Reason: Insufficient work space for snippet descriptor (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 408: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

400 June 2004

200255F4 RECO_ERROR_55_F4 Reason: Multiple defined snippet identifier (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F00 RECO_ERROR_5F_00 Reason: Insufficient work space for response (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F01 RECO_ERROR_5F_01 Reason: Insufficient work space for read results (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F02 RECO_ERROR_5F_02 Reason: Insufficient work space for image output (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 409: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 401

20025F03 RECO_ERROR_5F_03 Reason: Insufficient work space for dictionary (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F04 RECO_ERROR_5F_04 Reason: Dictionary services not licensed by WIBU-Key (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F05 RECO_ERROR_5F_05 Reason: WIBU-Key not plugged in or invalid (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F06 RECO_ERROR_5F_06 Reason: WIBU-Key counter expired, WIBU-Key error code (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 410: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

402 June 2004

20025F07 RECO_ERROR_5F_07 Reason: Internal lack of memory (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F12 RECO_ERROR_5F_12 Reason: Internal error: unknown recognition command. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F13 RECO_ERROR_5F_13 Reason: Internal error: cannot initialize image processor. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F20 RECO_ERROR_5F_20 Reason: ´Open read´ error on dictionary file (file service). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 411: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 403

20025F21 RECO_ERROR_5F_21 Reason: Dictionary damaged: invalid header (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F22 RECO_ERROR_5F_22 Reason: Dictionary damaged: too large (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F23 RECO_ERROR_5F_23 Reason: Dictionary damaged: error reading data (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F24 RECO_ERROR_5F_24 Reason: ´Open write´ error dictionary file (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 412: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

404 June 2004

20025F25 RECO_ERROR_5F_25 Reason: Write error on dictionary file (file service). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F26 RECO_ERROR_5F_26 Reason: Internal error at dictionary administration: error code from module "lex-pflege". Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F27 RECO_ERROR_5F_27 Reason: Internal error at dictionary access: error code from module "call-pasulex". Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F28 RECO_ERROR_5F_28 Reason: Dictionary damaged: invalid "time" entry (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 413: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 405

20025F29 RECO_ERROR_5F_29 Reason: Dictionary damaged: invalid "old_time" entry (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F2A RECO_ERROR_5F_2A Reason: Dictionary damaged: too large (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F2C RECO_ERROR_5F_2C Reason: Dictionary damaged: file information (DI) too large (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20025F2D RECO_ERROR_5F_2D Reason: Dictionary damaged: file information (DI) invalid (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 414: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

406 June 2004

20025F2E RECO_ERROR_5F_2E Reason: Dictionary damaged: too small (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027500 RECO_ERROR_75_00 Reason: LGK Lc_AdminLex: no dictionary loaded (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027501 RECO_ERROR_75_01 Reason: LGK Lc_AdminLex: invalid parameter "awnk" (application number). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027502 RECO_ERROR_75_02 Reason: LGK Lc_AdminLex: invalid parameter "nrtl" (number of partial dictionary too large). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 415: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 407

20027503 RECO_ERROR_75_03 Reason: LGK Lc_AdminLex: invalid parameter "funco" (function code). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027505 RECO_ERROR_75_05 Reason: LGK Lc_AdminLex: selected partial dictionary doesn´t exist, internal code 5. Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027506 RECO_ERROR_75_06 Reason: LGK Lc_AdminLex: selected partial dictionary doesn´t exist, internal code 6. Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002750A RECO_ERROR_75_0A Reason: Dictionary damaged: invalid dictionary mode (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 416: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

408 June 2004

2002750C RECO_ERROR_75_0C Reason: Dictionary damaged: too many partial dictionaries (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002750D RECO_ERROR_75_0D Reason: Dictionary damaged: minimum string length too small (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002750E RECO_ERROR_75_0E Reason: Dictionary damaged: maximum string length too large (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002750F RECO_ERROR_75_0F Reason: Dictionary damaged: maximum string length less than or equal to minimum string length (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 417: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 409

20027512 RECO_ERROR_75_12 Reason: Dictionary damaged: overlap of length ranges (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027514 RECO_ERROR_75_14 Reason: Dictionary damaged: faulty dictionary entry (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027515 RECO_ERROR_75_15 Reason: Dictionary damaged: delimiter (0) missing at the end of a length area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027521 RECO_ERROR_75_21 Reason: Dictionary damaged: too many terms in a length area (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 418: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

410 June 2004

20027523 RECO_ERROR_75_23 Reason: LGK Lc_GetLex: no dictionary loaded (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027525 RECO_ERROR_75_25 Reason: LGK Lc_GetLexStat: no dictionary loaded (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027528 RECO_ERROR_75_28 Reason: LGK Lc_GetLexStat: partial dictionary doesn´t exist (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

20027529 RECO_ERROR_75_29 Reason: LGK Lc_AdminLex: function code no longer supported (generate/delete partial dictionary). Internal error. Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 419: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Scanner software RecoStar (RECO)

June 2004 411

2002A101 RECO_ERROR_A1_01 Reason: "send" expected, "receive" received (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002A102 RECO_ERROR_A1_02 Reason: "receive" expected, "send" received (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

2002A501 RECO_ERROR_A5_01 Reason: Command not allowed in present unit status (internal error). Application: Abort the current transaction. Measure: Report the error log of this entry to service.

Page 420: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

412 June 2004

Page 421: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 413

Cash-Out Module (CDM) StClass:

STCLASS_OK No error STCLASS_ERROR_CDM Error of the CSCWCDM.DLL

StCode:

20008000 CDM_INVALID_CAS_SLOT Reason: Invalid cassette slot. Application: Get status in order to determine the maximum number of cassette slots.

20008001 CDM_ERROR_SELFTEST Reason: Error in self-test. Measure: Check acknowledge buffer and hardware.

20008002 CDM_INVALID_ERROR_DATA Reason: Internal error. Possible hardware error. Measure: Report the error log of this entry to Service. Check the hardware if necessary.

20008003 CDM_INVALID_WARNING_DATA Reason: Internal error. Possible hardware error. Measure: Report the error log of this entry to Service. Check the hardware if necessary.

Page 422: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

414 June 2004

20008004 CDM_CSCEDS_DLL_NOT_FOUND Reason: The error only occurs with the coded V.24 line to the CDM. The CSCEDS.DLL file was not found in the <CSCROOT>\DLL directory. Measure: Copy the DLL into the <CSCROOT>\DLL directory from the release diskette.

20008005 CDM_CSCEDS_DLL_OPEN_FAILED Reason: The DLL for software encoding, CSCEDS.DLL, could not be opened. Measure: Check access rights and attributes of this file.

20008006 CDM_INVALID_CRC Reason: Invalid CRC (check character) received with encoded line. Measure: Initialize the line again. Check the hardware.

20008007 CDM_INVALID_KEYWORD_LEN Reason: The keyword specified in the parameter block has an invalid length. Application: Check application program.

20008009 CDM_INVALID_CAS_DATA_SEL Reason: The segment selector of the pointer for the input buffer "CdmCasPara.pData" specified in the parameter block is invalid. Application: Check application program.

Page 423: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 415

28000100 CDM_INVALID_TRANSPORT Reason: No cash in collecting tray for transport command. A cash-out command has been issued without previous dispensation, or no money has been detected in the collecting tray. Application: Check the application Determine why there is no cash in the collecting tray. Change application program if necessary.

28000200 CDM_TRANSP_DIR_NOT_AVAIL Reason: Transport in the desired direction is illegal. Application: Correct parameter in transport job.

28000300 CDM_REJ_CAS_FULL Reason: Remaining capacity of the reject cassette too small. The number of banknotes to be dispensed for this job cannot be transported into the reject cassette as the remaining capacity in the reject cassette is insufficient. Application: Terminate transaction, lock cash-out function. Measure: Operator call (empty reject cassette)

28000400 CDM_PLAUSIBILITY_ERROR Reason: Plausibility check on job unsuccessful (syntax error in job) or wrong controller setting. Application: Correct application program. Measure: Check the controller setting.

28001000 CDM_INVALID_BLK_LEN Reason: Incorrect block length. Error in job. Application: Correct application program.

Page 424: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

416 June 2004

28001100 CDM_INVALID_DEV_ID Reason: Incorrect device specification. Error in job. Application: Correct application program.

28001200 CDM_INVALID_COMMAND Reason: Wrong job specification / Job not available - Error in job - Separator locked (Retract and quit executed, RTR_LOCK:Y) - Retract job issued although no transport job carried out first Measure: Correct application program or release separator after removal of retraced cash from stackers (RTR_LOCK:N)

28001300 CDM_INVALID_COMMAND_LEN Reason: Incorrect job length. Error in job. Application: Correct application program.

28001400 CDM_SUBMODUL_NOT_AVAIL Reason: The cassette addressed by the application does not exist (programming error). The measuring station, photosensor amplifier or the cassette cannot be accessed via the internal interface (hardware error). Application: Correct the application program. In the case of hardware errors terminate the transaction, disable the cash-out function. Measure: Insert cassette in cassette position and log on Check hardware (switches, contacts, lines)!

28001500 CDM_INVALID_STATUS_SPEC Reason: Attempt to read from an unknown area during a status job. Application: Change application program.

Page 425: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 417

28001600 CDM_INVALID_AREA Reason: An unknown name has been transferred in a status job. Application: Change application program.

28001700 CDM_INVALID_BLK_LEN_CHAR Reason: Length specification in the job not hexadecimal. Syntax error in job. Application: Change application program.

28001800 CDM_INVALID_TRANSPORT_SPEC Reason: An invalid transport destination has been specified in the job. Application: Change application program.

28001900 CDM_INVALID_SEPARATOR Reason: An illegal separator has been used in the job. Application: Change application program.

28001A00 CDM_BUSY Reason: A job was previously issued and is still busy (e.g. log on cassette without time monitor), so the current job cannot yet be processed. Application: Change application program or terminate the previous job.

28001B00 CDM_CAS_PROT_ERROR_AREA_N Reason: An attempt has been made to write in the write-protected area (AREA_N) of the cassette EE-PROM. Application: Change application program.

Page 426: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

418 June 2004

28001C00 CDM_PUT_NOT_AVAIL Reason: There is no PUT PROM in the cash-out controller This message only occurs in self-test jobs. Measure: You can continue to use the device even without the PUT PROM. Customer Service should be informed and the cash-out controller should be equipped with a PUT PROM

28001D00 CDM_INVALID_SPEC_LBAMP Reason: An illegal specification has been transferred in the supervisor job for accessing the photosensor amplifier. Application: Change application program.

28002000 CDM_VALUE_NOT_AVAIL_R Reason: Amount demanded cannot be dispensed. Cash can basically still be dispensed. In currency-dependent dispensing: the desired amount cannot be dispensed. In currency-independent dispensing: the desired combination of banknotes cannot be dispensed. Application: Read out the warning status of the cassette and make a cassette-specific evaluation. Measure: As further banknotes can be dispensed, no immediate action is required. Apart from this, reaction according to the message.

28002100 CDM_LB_MS_TIMEOUT Reason: Time-out in photosensor of measuring station Money jam in the transport path between path monitor of first dispensing module and photosensor of measuring station. Application: Disable cash-out function Measure: Open device, check transport paths for remaining banknotes, if necessary inform system administrator.

Page 427: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 419

28002200 CDM_LB_L1_TIMEOUT Reason: Time-out photosensor L1 Money jam in transport path between the photosensor of the measuring station and photosensor L1. Application: Disable cash-out function Measure: Open device, check transport paths for remaining banknotes. If necessary, inform system administrator.

28002300 CDM_LB_COL_TRAY_TIMEOUT Reason: Time-out for collecting tray photosensor L19 Money jam in the transport path between photosensor L1 and photosensor L19. Application: Disable cash-out function Measure: Open device, check transport paths for remaining banknotes. If necessary, inform system administrator.

28002400 CDM_LB_REJ_TIMEOUT Reason: Time-out in photosensor L20 for reject cassette Money jam in transport path between photosensor L1 and reject cassette photosensor L20. Application: Disable cash-out function Measure: Open device, check transport paths for remaining banknotes. If necessary, inform system administrator.

28002500 CDM_SINGLE_REJ_ERROR Reason: Single reject switch defective (Hardware error) Cash-out function can still be operated, but no further single rejects (only bundle rejects). Measure: Check single reject switch

Page 428: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

420 June 2004

28002600 CDM_DOUPLE_DISPENSING Reason: All banknotes were identified as multiple dispenses. Contents of cassette: - the cassette contains the wrong banknotes. Hardware error: - the cassette or the dispenser module is defective - the measuring station is defective, i.e. all banknotes are recognized as illegal Application: With the wrong cassette contents, evaluate the warning status for the cassette or lock the cassette, if necessary. Measure: Check cassette contents, inform system administrator. Check cassette, dispenser module, measuring station. If necessary, carry out Reference value determination.

28002700 CDM_DMODUL_ERROR Reason: In the dispensing procedure, additional banknotes have been dispensed without the clutch being supplied with power. The dispenser module is defective (Hardware error). Application: Lock the dispenser module for cash-out transactions Measure: Check the dispenser module

Page 429: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 421

28002800 CDM_VALUE_NOT_AVAIL_A Reason: Requested amount cannot be dispensed Contents of cassette: This amount cannot be dispensed in the selected currency, however, other currencies (if any) can still be dispensed. - cassette(s) empty - cassette(s) locked (software lock) Hardware error: - cassette(s) locked (hardware lock) - no reference value in measuring station - money jam in dispenser module - values in cassette(s) not up-to-date - main motor of cash-out module not functioning or too slow Application: Read out the warning status. If necessary, lock cash-out for the currency Measure: Action appropriate to message.

28002900 CDM_CAS_INVALID_CURRENCY Reason: There is no cassette for the requested currency or the job contained the wrong value in the parameter for the desired currency. Application: For programming errors only: change application program Measure: Cassette error: Request the system operator to insert a cassette with the desired currency

28002A00 CDM_INVALID_NR_NOTES Reason: The parameter specifying the banknote denomination in the job is larger than the allowed maximum (maximum = 40 banknotes) Application: Change application program

Page 430: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

422 June 2004

28002B00 CDM_ERROR_LBAMP Reason: Evaluation electronics of the photosensor amplifier defect (Hardware error). Application: Disable cash-out Measure: Call Customer Service: Replace controller for cash-out module

28002C00 CDM_INVALID_CONFIG Reason: Unknown device configuration (Hardware error) Application: Disable cash-out function Measure: Carry out device initialization (the cassettes have to be removed first, there should be no banknotes in the transport path and all photosensors should be open) If device initialization cannot be carried out successfully, replace the controller for the dispenser module.

28002D00 CDM_LB_L17_L25_ERROR Reason: Photosensor L1, L17, L25 or control of individual reject switches defective (Hardware error). Application: Disable cash-out function Measure: Check photosensor and individual reject switch and replace if necessary.

28003100 CDM_DMODUL_1_TIMEOUT Reason: Time-out of path monitor in first dispenser module Banknote jam, banknote(s) do not reach the path monitor photosensor in the first dispenser module. Application: Disable cash-out function Measure: Eliminate money jam, check whether any bank- notes are in the transport path, if necessary inform system administrator.

Page 431: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 423

28003200 CDM_DMODUL_2_TIMEOUT Reason: Time-out of path monitor in second dispenser module Money jam, banknote(s) do not reach the path monitoring photosensor in the second dispenser module. Application: Disable cash-out function Measure: Eliminate money jam, check whether there are any banknotes in the transport path, if necessary inform system administrator.

28003300 CDM_DMODUL_3_TIMEOUT Reason: Time-out of path monitor in third dispenser module Money jam, banknote(s) do not reach the path monitoring photosensor in the third dispenser module. Application: Disable cash-out function Measure: Eliminate money jam, check whether there are any banknotes in the transport path, if necessary inform system administrator.

28003400 CDM_DMODUL_4_TIMEOUT Reason: Time-out of path monitor in fourth dispenser module Money jam, banknote(s) do not reach the path monitoring photosensor in the fourth dispenser module. Application: Disable cash-out module Measure: Eliminate money jam, check whether there are any banknotes in the transport path, if necessary inform the system administrator.

Page 432: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

424 June 2004

28003500 CDM_DMODUL_5_TIMEOUT Reason: Time-out of path monitor in fifth dispenser module Money jam; banknote(s) do not reach the path monitoring photosensor of the fifth dispenser module. Application: Disable cash-out function Measure: Eliminate money jam, check whether there are any banknotes in the transport path, if necessary inform the system administrator.

28005000 CDM_LB_L17_CONVERED Reason: Photosensor L17 blocked UNDEFINED CASH OPERATION!! Money jam, there is still at least one banknote under the photosensor indicated. Customer can access part of the cash and/or manipulates L17. Application: Disable cash-out function Measure: Remove money jam, check transport path. Inform system administrator where appropriate (check photosensor)

28005100 CDM_LB_L18_OR_L22_CONVERED Reason: Photosensor L18 or L22 blocked UNDEFINED CASH OPERATION !! Money jam, there is still at least one banknote under the photosensor indicated. Application: Disable cash-out function Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensor)

Page 433: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 425

28005110 CDM_R_LB_L18_COVERED Reason: Photosensor L18 does not become free Cash not accessible by customer! Money jam, there is at least 1 banknote under the photosensor specified. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

28005111 CDM_R_LB_L18_RETRACT_COVERED Reason: Photosensor L18 does not become free Retract not carried out properly shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is at least 1 banknote under the photosensor specified. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005118 CDM_R_LB_L18_NOT_REACHED Reason: Photosensor L18 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

Page 434: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

426 June 2004

28005119 CDM_R_LB_L18_RETR_NOT_REACHED Reason: Photosensor L18 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam with retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path if necessary inform system administrator (check photosensors)

28005200 CDM_LB_L19_COVERED Reason: Photosensor L19 blocked UNDEFINED CASH OPERATION!! Money jam, there is still at least one banknote under the photosensor indicated. Application: Disable cash-out function Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensor)

28005210 CDM_R_LB_L19_COVERED Reason: Photosensor L19 does not become free Cash not accessible by customer! Money jam during delivery, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

Page 435: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 427

28005211 CDM_R_LB_L19_RETRACT_COVERED Reason: Photosensor L19 does not become free Retract not carried out properly shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005218 CDM_R_LB_L19_NOT_REACHED Reason: Photosensor L19 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005219 CDM_R_LB_L19_RETR_NOT_REACHED Reason: Photosensor L19 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 436: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

428 June 2004

28005300 CDM_LB_L20_COVERED Reason: Photosensor L20 blocked. UNDEFINED CASH OPERATION!! Money jam, there is still at least one banknote under the photosensor indicated. Application: Disable cash-out function Measure: Eliminate money jam, check transport path, if necessary inform system administrator (check photosensor)

28005400 CDM_LB_L21_COVERED Reason: Photosensor L21 blocked THE COMPLETE AMOUNT CAN BE ACCESSED BY THE CUSTOMER !! Money jam, there is still at least one banknote under the photosensor indicated. Application: Disable cash-out function Measure: Eliminate money jam, check transport path, if necessary inform system administrator (check photosensor)

28005410 CDM_R_LB_L21_COVERED Reason: Photosensor L21 does not become free Cash not accessible by customer! Money jam during single reject. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path, If necessary inform system administrator (check photosensors)

Page 437: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 429

28005418 CDM_R_LB_L21_NOT_REACHED Reason: Photosensor L21 is not reached Cash not accessible by customer! Money jam during single reject Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path, If necessary inform system administrator (check photosensors)

28005500 CDM_LB_L22_COVERED Reason: Photosensor L22 does not become free UNDEFINED CASH-OUT!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Disable cash-out function Measure: Eliminate money jam, check transport path, If necessary inform system administrator (check photosensors)

28005510 CDM_R_LB_L22_COVERED Reason: Photosensor L22 does not become free Cash not accessible by customer! Money jam during delivery, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

Page 438: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

430 June 2004

28005511 CDM_R_LB_L22_RETRACT_COVERED Reason: Photosensor L22 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005518 CDM_R_LB_L22_NOT_REACHED Reason: Photosensor L22 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005519 CDM_R_LB_L22_RETR_NOT_REACHED Reason: Photosensor L22 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 439: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 431

28005610 CDM_R_LB_L23_COVERED Reason: Photosensor L23 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005611 CDM_R_LB_L23_RETRACT_CONVERED Reason: Photosensor L23 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005618 CDM_R_LB_L23_NOT_REACHED Reason: Photosensor L23 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 440: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

432 June 2004

28005619 CDM_R_LB_L23_RETR_NOT_REACHED Reason: Photosensor L23 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28005700 CDM_SWIVEL_ARM_ERROR_DOWN Reason: Does not reach the bottom Collecting tray swivel arm. The amount cannot be accessed by the customer ! Hardware error Application: Disable cash-out function Measure: Check swivel arm, sensor

28005710 CDM_R_SWIVEL_ARM_ERROR_DOWN Reason: Swivel arm does not reach the bottom. The amount cannot be accessed by the customer ! Hardware error Application: Disable cash-out function Measure: Check swivel arm, sensor

Page 441: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 433

28005800 CDM_SWIVEL_ARM_ERROR_UP Reason: Collecting tray swivel arm does not reach the top. The amount cannot be accessed by the customer ! Hardware error Application: Disable cash-out function Measure: Check swivel arm, sensor

28005810 CDM_R_SWIVEL_ARM_ERROR_UP Reason: Swivel arm does not reach the top position. Cash not accessible by customer! Hardware error Application: Disable cash-out function Measure: Check swivel arm, sensor

28005B00 CDM_CASH_SLOT_ERROR_DOWN Reason: Money slot/shutter does not close completely Hardware error The error code is used as general error message with outdoor units with integrated door module (exception: door module is controlled by application). The door module signals the error code when, - the door cannot be closed or opened completely, - the photo sensor in the cash trough or cash slot are covered partially or completely, - the manual switch for the door module is in manual mode position. Application: Disable cash-out function Measure: Check money slot, sensor, shutter

Page 442: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

434 June 2004

28005B10 CDM_R_SHUTTER_CLOSE_ERROR Reason: Shutter was not closed completely Cash not accessible by customer! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

28005B11 CDM_R_SHUTTER_RETR_CLOSE_ERR1 Reason: Shutter was not closed completely Retract correctly performed CASH WAS ACCESSIBLE BY CUSTOMER!!! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

28005B12 CDM_R_SHUTTER_RETR_CLOSE_ERR2 Reason: Shutter was not closed completely Retract not carried out properly CASH WAS ACCESSIBLE BY CUSTOMER!!! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

Page 443: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 435

28005B13 CDM_R_SHUTTER_CLOSE_ERROR2 Reason: Shutter was not closed completely CUSTOMER REMOVED THE CASH Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

28005C00 CDM_CASH_SLOT_ERROR_UP Reason: Money slot/shutter does not open completely The amount cannot be accessed by the customer ! Hardware error or the module is being manipulated Application: Disable cash-out function Measure: Check money slot, sensor, shutter

28005C10 CDM_R_SHUTTER_OPEN_ERROR Reason: Shutter does not open completely CASH IS ACCESSIBLE BY CUSTOMER!!! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

Page 444: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

436 June 2004

28005C11 CDM_R_SHUTTER_RETR_OPEN_ERR1 Reason: Shutter was not completely open Retract correctly performed CASH WAS ACCESSIBLE BY CUSTOMER!!! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

28005C12 CDM_R_SHUTTER_RETR_OPEN_ERR2 Reason: Shutter was not completely open Retract not carried out properly CASH WAS ACCESSIBLE BY CUSTOMER!!! Hardware error or manipulation of module Application: Disable cash-out function Measure: Check shutter, sensor

28005C13 CDM_R_SHUTTER_OPEN_ERROR2 Reason: Shutter was not completely open CUSTOMER REMOVED THE CASH !!! Hardware error or manipulation of module Application: If repeated: Disable cash-out function Measure: Check shutter, sensor

Page 445: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 437

28005D00 CDM_FEED_JAM_LB_L17 Reason: Money does not reach L17 The amount cannot be accessed by the customer ! Money jam in transport path from L18/L22 to L17 Application: Disable cash-out function Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

28005D10 CDM_R_MOTOR2_NO_CLOCKS Reason: Transport motor M2 does not return timing pulses Cash transport to customer aborted Cash not yet accessible by customer! Hardware error Application: Disable cash-out function Measure: Check transport motor M2

28005D11 CDM_R_MOTOR2_RETR_NO_CLOCKS Reason: Transport motor M2 does not return timing pulses Retract transport aborted CASH WAS ACCESSIBLE BY CUSTOMER!!! Hardware error Application: Disable cash-out function Measure: Check transport motor M2

Page 446: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

438 June 2004

28005F10 CDM_R_LB_L25_COVERED Reason: Photosensor L25 blocked The amount cannot be accessed by the customer ! Money jam, there is still at least one banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path. If necessary inform system administrator (check photosensors)

28005F11 CDM_R_LB_L25_RETRACT_COVERED Reason: Photosensor L25 does not become free Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary, inform system administrator (check photosensors)

28005F18 CDM_R_LB_L25_NOT_REACHED Reason: Photosensor L25 is not reached Cash not accessible by customer Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary, inform system administrator (check photosensors).

Page 447: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 439

28005F19 CDM_R_LB_L25_RETR_NOT_REACHED Reason: Photosensor L25 is not reached Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary, inform system administrator (check photosensors)

28006300 CDM_FEED_JAM_LB_L21 Reason: Money does not reach L21 (bundle reject) The money cannot be accessed by the customer ! Money jam on transport path between L18/L22 and L21 Application: Disable cash-out function Measure: Eliminate money jam, check transport paths System administrator: (check photosensors)

28006310 CDM_R_LB_L21_REJECT_COVERED Reason: Photosensor L21 does not become free during bundle reject Cash not accessible by customer! Money jam during bundle reject. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path System administrator: (check photosensors)

Page 448: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

440 June 2004

28006311 CDM_R_LB_L21_RETRACT_COVERED Reason: Photosensor L21 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path System administrator: (check photosensors)

28006318 CDM_R_LB_L21_REJECT_NOT_REACHED Reason: Photosensor L21 not reached during bundle reject Cash not accessible by customer! Money jam during bundle reject Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path System administrator: (check photosensors)

28006319 CDM_R_LB_L21_RETR_NOT_REACHED Reason: Photosensor L21 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path System administrator: (check photosensors)

Page 449: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 441

28007010 CDM_R_LB_L26_COVERED Reason: Retract was performed correctly after TIMEOUT with cash presentation Photosensor L26 did not become free Customer did not remove cash with the time specified in TO_CUSTM. When command CDnTROL or CDnTROD (transport cash into frontload - or default direction) was issued, a retract was performed. Impossible to say what was retracted. Measure: None since system is completely operable.

28007011 CDM_R_LB_L26_RETRACT_COVERED Reason: Photosensor L26 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Customer could access part of the banknotes and/or manipulated L26. Measure: Eliminate money jam, check transport path If necessary inform system administrator ( check photosensors)

28007012 CDM_R_LB_L26_UE_COVERED Reason: Photosensor L26 unexpectedly covered Cash not accessible by customer! Manipulation Application: Repeat complete separation and transport. If error recurs: Disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator ( check photosensors)

Page 450: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

442 June 2004

28007013 CDM_R_LB_L26_RETRACT_UE_COVERED Reason: Photosensor L26 unexpectedly covered Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Manipulation, cash was offered correctly before. Photosensor L26 was covered unexpectedly from outside while cash was retracted. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007018 CDM_R_LB_L26_NOT_REACHED Reason: Photosensor L26 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007019 CDM_R_LB_L26_BEFORE_RETR_FREE Reason: Photosensor L26 already free before retract command CUSTOMER REMOVED THE CASH !!! Customer removed cash completely before retract command. Cash-out was performed correctly.

28007110 CDM_R_LB_L27_COVERED Reason: Retract was performed correctly after TIMEOUT with cash presentation Photosensor L27 did not become free Customer did not remove cash within the time specified in TO_CUSTM. On command TRANSPORT CASH INTO REARLOAD or DEFAULT DIRECTION, a retract was performed. Impossible to say what was retracted. Measure: None since system is completely operable.

Page 451: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 443

28007111 CDM_R_LB_L27_RETRACT_COVERED Reason: Photosensor L27 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Customer had access to part of the banknotes Application: Disable cash-out function Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007112 CDM_R_LB_L27_UE_COVERED Reason: Photosensor L27 unexpectedly covered Cash not accessible by customer! Manipulation Application: Repeat complete separation and transport. If error recurs: Disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007113 CDM_R_LB_L27_RETRACT_UE_COVERED Reason: Photosensor L27 unexpectedly covered Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Manipulation, the cash was offered correctly before. Photosensor L27 was covered unexpectedly from the outside while cash was retracted. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 452: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

444 June 2004

28007118 CDM_R_LB_L27_NOT_REACHED Reason: Photosensor L27 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007119 CDM_R_LB_L27_BEFORE_RETR_FREE Reason: Photosensor L27 becomes free nevertheless CUSTOMER REMOVED THE CASH !!! Customer removed cash completely at beginning of retract command. Cash-out was performed correctly.

28007210 CDM_R_LB_L28_COVERED Reason: Photosensor L28 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 453: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 445

28007211 CDM_R_LB_L28_RETRACT_COVERED Reason: Photosensor L28 does not become free Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007218 CDM_R_LB_L28_NOT_REACHED Reason: Photosensor L28 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007219 CDM_R_LB_L28_RETR_NOT_REACHED Reason: Photosensor L28 is not reached Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 454: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

446 June 2004

28007310 CDM_R_LB_L29_COVERED Reason: Photosensor L29 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007311 CDM_R_LB_L29_RETRACT_COVERED Reason: Photosensor L29 does not become free Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007318 CDM_R_LB_L29_NOT_REACHED Reason: Photosensor L29 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 455: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 447

28007319 CDM_R_LB_L29_RETR_NOT_REACHED Reason: Photosensor L29 is not reached Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007410 CDM_R_LB_L30_COVERED Reason: Photosensor L30 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007411 CDM_R_LB_L30_RETRACT_COVERED Reason: Photosensor L30 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 456: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

448 June 2004

28007418 CDM_R_LB_L30_NOT_REACHED Reason: Photosensor L30 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE). If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007419 CDM_R_LB_L30_RETR_NOT_REACHED Reason: Photosensor L30 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007510 CDM_R_LB_L31_COVERED Reason: Photosensor L31 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 457: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 449

28007511 CDM_R_LB_L31_RETRACT_COVERED Reason: Photosensor L31 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007518 CDM_R_LB_L31_NOT_REACHED Reason: Photosensor L31 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007519 CDM_R_LB_L31_RETR_NOT_REACHED Reason: Photosensor L31 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 458: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

450 June 2004

28007610 CDM_R_LB_L32_COVERED Reason: Photosensor L32 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007611 CDM_R_LB_L32_RETRACT_COVERED Reason: Photosensor L32 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007618 CDM_R_LB_L32_NOT_REACHED Reason: Photosensor L32 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 459: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 451

28007619 CDM_R_LB_L32_RETR_NOT_REACHED Reason: Photosensor L32 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007710 CDM_R_LB_L33_COVERED Reason: Photosensor L33 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007711 CDM_R_LB_L33_RETRACT_COVERED Reason: Photosensor L33 does not become free Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 460: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

452 June 2004

28007718 CDM_R_LB_L33_NOT_REACHED Reason: Photosensor L33 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007719 CDM_R_LB_L33_RETR_NOT_REACHED Reason: Photosensor L33 is not reached Retract not carried out properly Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007910 CDM_R_LB_L35_COVERED Reason: Photosensor L35 does not become free Cash not accessible by customer! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 461: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 453

28007911 CDM_R_LB_L35_RETRACT_COVERED Reason: Photosensor L35 does not become free Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam, there is still at least 1 banknote under the photosensor indicated. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007918 CDM_R_LB_L35_NOT_REACHED Reason: Photosensor L35 is not reached Cash not accessible by customer! Money jam during delivery. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

28007919 CDM_R_LB_L35_RETR_NOT_REACHED Reason: Photosensor L35 is not reached Shutter was completely open and is closed again completely CASH WAS ACCESSIBLE BY CUSTOMER!!! Money jam during retract. Application: Issue job TRANSPORT CASH INTO REJECT CASSETTE. If error recurs, disable cash-out function. Measure: Eliminate money jam, check transport path If necessary inform system administrator (check photosensors)

Page 462: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

454 June 2004

28007B10 CDM_R_G9_NOT_REACHED Reason: Photosensor G9 (bundle reject switch) is not reached Cash not accessible by customer! Hardware error Bundle reject switch does not reach reject position. Application: Disable cash-out function Measure: Check transport path, reject rocker for function, if necessary notify system administrator

28007B11 CDM_R_G9_RETRACT_NOT_REACHED Reason: Photosensor G9 (bundle reject switch) is not reached Retract not carried out properly CASH WAS ACCESSIBLE BY CUSTOMER!!! Bundle reject switch does not reach reject position. Reject rocker cannot be moved into reject position in order to complete the retract operation. The retract operation is in the collecting tray. Application: Disable cash-out function Measure: Check transport path, reject rocker for function, if necessary notify system administrator

28007C10 CDM_R_G8_NOT_REACHED Reason: Photosensor G8 (bundle reject switch) is not reached Cash not accessible by customer! Hardware error Bundle reject switch does not reach transport position Application: Disable cash-out function Measure: Check transport path, reject rocker for function, if necessary notify system administrator (check photosensors)

Page 463: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 455

28007C11 CDM_R_G8_RETRACT_NOT_REACHED Reason: Photosensor G8 (bundle reject switch) is not reached Retract not carried out properly CASH WAS ACCESSIBLE BY CUSTOMER!!! Bundle reject switch does not reach transport position. The retract operation does not reach the collecting tray. Application: Disable cash-out function Measure: Check transport path, reject rocker for function, if necessary notify system administrator (check photosensors)

28009000 CDM_MS_TIMEOUT Reason: Time-out during communication with the measuring station (Hardware error) Application: Repeat job, if the error occurs again, disable the cash-out function Measure: Check electronic measuring station, wiring

28009100 CDM_LBAMP_TIMEOUT Reason: Time-out during communication with the photosensor amplifier. If this error occurs in a transport command, AN UNDEFINED CASH-OUT TAKES PLACE!! Sporadic error or Hardware error Application: Repeat job, if the error occurs again, disable the cash-out function Measure: Check electronic controller, wiring

Page 464: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

456 June 2004

28009200 CDM_CUS_RELAIS_NOT_AVAIL Reason: Customer relay not connected Hardware error, Programming error Application: f necessary, change program, otherwise: Measure: Check customer relay, cable connections

2800B000 CDM_CAS_RELEASE_ERROR Reason: Error when releasing the cassette An error has occurred while one or several cassette(s) were released Application: Repeat job, if the error occurs again, read out cassette and warning status (Code word for cassette status: "____STAT", if necessary, call Customer Service) Measure: Check cassette, dispenser module, wiring

2800B100 CDM_CAS_INSERT_ERROR Reason: Error when initiating the cassette An error has occurred when one or several cassette(s) were being initialized Application: Repeat job, if the error occurs again, read out cassette and warning status (Code word for cassette status: "____STAT", if necessary, call Customer Service) Measure: Check cassette, dispenser module, wiring

2800B200 CDM_REJ_CAS_NOT_AVAIL Reason: No reject cassette The reject cassette has not been inserted in the module or a hardware error has occurred (cable, sensor). Measure: Insert reject cassette System administrator: Check cassette, dispenser module, wiring

Page 465: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 457

2800B300 CDM_CAS_NOT_AVAIL Reason: There is no dispensing cassette At least one of the cassettes called in a dispensing job is not available or a hardware error has occurred (cable, sensor) Application: Specify another denomination, activate alternative denomination or Measure: Log on and insert the missing cassette(s) System administrator: Check cassette, dispenser module, wiring

2800B400 CDM_CAS_HANDLING_TIMEOUT Reason: Time-out at cassette initialization/release It was not possible to initialize or release the cassette successfully in the time specified in the job. Measure: Repeat the job and insert the relevant cassette(s) System administrator: Check cassette, dispenser module (switch), wiring

2800B510 CDM_MS_EEPROM_ERROR Reason: EE-PROM defect (Hardware error) Measure: Replace the measuring station electronics, if necessary, replace sensor

2800B511 CDM_MS_MOTOR_ERROR Reason: Main motor is not working (Hardware error) Measure: Replace the measuring station electronics, if necessary, replace sensor

2800B512 CDM_MS_MOTOR_SPEED_ERROR Reason: Incorrect motor speed (Hardware error) Measure: Replace the measuring station electronics, if necessary, replace sensor

Page 466: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

458 June 2004

2800B513 CDM_MS_CPU_ERROR Reason: Hardware error (processor) Measure: Replace the measuring station electronics, if necessary, replace sensor

2800B514 CDM_MS_EPROM_ERROR Reason: Hardware error (E-PROM) Measure: Replace the measuring station electronics, if necessary, replace sensor

2800B523 CDM_CAS_BUSY Reason: Cassette busy (pressure being accumulated) Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B530 CDM_CAS_NO_REJECT_POSSIBLE Reason: Reject position cannot be reached. Reject processes are no longer possible (also no single reject). Cash not accessible by customer! Measure: Replace controller; if necessary, replace the electronics of the dispenser module. Check Reject cassette.

2800B531 CDM_CAS_NO_RETRACT_POSSIBLE Reason: Retract position cannot be reached. No retracts can be performed any longer. Rejects are possible. CASH WAS ACCESSIBLE BY CUSTOMER!! Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B534 CDM_CAS_CPU_ERROR Reason: Processor defect Measure: Replace controller; if necessary, replace the electronics of the dispenser module

Page 467: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 459

2800B535 CDM_CAS_RAM_ERROR Reason: RAM defect Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B536 CDM_CAS_EPROM_CHKSUM_ERROR Reason: Checksum error, E-PROM Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B537 CDM_CAS_EEPROM_CHKSUM_ERROR Reason: Checksum error, EE-PROM Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B538 CDM_CAS_CLUTCH_ERROR Reason: Clutch signal error Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B539 CDM_CAS_DEDUCTIONFLAG_ERROR Reason: Dispensing sensor error Measure: Replace controller; if necessary, replace the electronics of the dispenser module

2800B544 CDM_LBAMP_HW_ERROR Reason: Evaluation electronics defect Measure: Replace controller, if necessary first re-initialize the device

Page 468: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

460 June 2004

2800B545 CDM_LBAMP_DISP_HW_NOT_AVAIL Reason: Card is not in a device Measure: Replace controller, if necessary first re-initialize the device

2800B546 CDM_LBAMP_INVALID_CONFIG Reason: Device could not be identified Measure: Replace controller, if necessary first re-initialize the device

2800B547 CDM_LBAMP_LB_NOT_OFF Reason: Job currently not allowed Measure: Replace controller, if necessary first re-initialize the device

2800B548 CDM_LBAMP_INVALID_SPEC Reason: Job unknown Measure: Replace controller, if necessary first re-initialize the device

2800B600 CDM_CAS_AREA_NOT_AVAIL Reason: Area/sub-area selected does not exist. Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for cassettes Application: Change application program

Page 469: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 461

2800B700 CDM_CAS_NO_FREE_BLK_AVAIL Reason: No free block Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for cassettes Application: Change application program

2800B800 CDM_CAS_AREA_ALREADY_EXIST Reason: Area selected already exists. Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for cassettes Application: Change application program

2800B900 CDM_CAS_INVALID_CHAR Reason: Character cannot be written With read/write jobs in the customer-specific AREA, only characters in the range from 20h - FFh are allowed. Application: Change application program

2800BA00 CDM_CAS_WRITE_PROT_ERROR Reason: Attempt to write to a write-protected area During a write job in the cassette EE-PROM, an attempt has been made to write to a write-protected area Application: Change application program

Page 470: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

462 June 2004

2800BB00 CDM_CAS_EEPROM_ERROR Reason: Error during processing of the cassette EE-PROM Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for the cassette Application: Change application program

2800BC00 CDM_CAS_AREA_CLR_NOT_AVAIL Reason: Required area cannot be dissolved. Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for the cassette Application: Change application program

2800BD00 CDM_CAS_PASSWORD_ERROR Reason: Old password incorrect The old password was transferred incorrectly when an attempt was made to change the cassette password Application: Change application program. Specify correct password

2800BE00 CDM_CAS_SYNTAX_ERROR Reason: Syntax error in job Programming error in jobs involving the cassette EE-PROM (read/write jobs in customer-specific AREA) or error in password handling for the cassette Application: Change application program

Page 471: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 463

2800C000 CDM_INVALID_CAS Reason: Cash cannot be dispensed from the selected cassette as the cassette has not been inserted Measure: Insert cassette System administrator: Check cassette, dispenser module (switches, contacts)

2800C100 CDM_CAS_SW_LOCK Reason: Cash cannot be dispensed from the specified cassette. It has been locked by the application software. (CASnUSLO:Y;) Application: Unlock the cassette from the software side before repeating the job.

2800C200 CDM_CAS_HW_LOCK Reason: Hardware lock (no money, money jam in dispenser module, etc.) (CASnHWWLO:Y;) Application: Read out cassette status and cassette-specific warning status, react according to status

2800C300 CDM_REF_INIT_ERROR Reason: It was not possible to determine the reference value with the specified number of banknotes Application: The job should be carried out with the number of banknotes specified as 0, as the error will not occur in this case (automatic determination of the required number of banknotes) Measure: Repeat the job with a larger number of notes

2800C400 CDM_REF_INVALID_NR_NOTES Reason: The specified number of banknotes was too high for reference value determination (max. 40 banknotes) (syntax error in job) Application: Repeat the job with a number of banknotes < 40 or program the job with the number of banknotes = 0

Page 472: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

464 June 2004

2800C500 CDM_REF_TABLE_FULL Reason: It was not possible to determine the reference value because the table already contains the maximum of 248 reference values Measure: Replace the EE-PROM and re-initialize reference values

2800C600 CDM_CAS_PRESSURE_ERROR Reason: It was not possible to accumulate the data-specific pressure when the cassette capacity data are updated. Application: Repeat the job, if the error occurs again, lock the cassette Measure: Repeat update of capacity data. If the same message is issued again: Log the cassette on again and update the capacity data again. If the same message appears again: Check cassette contents (banknotes, slider, etc.). If necessary, inform system administrator System administrator: Replace wiring (check dispenser module, cassette), if necessary, replace cassette

2800D000 CDM_TRANS_KEY_NOT_AVAIL Reason: The transport key (TK) for line encryption between the central unit and the controller of the cash-out module is missing. Application: If necessary, change application program Measure: Start encryption new

2800D100 CDM_LINE_KEY_NOT_AVAIL Reason: The line key (LK) for line encryption between the central unit and the controller of the cash-out module is missing. Measure: Start encryption new

Page 473: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 465

2800D200 CDM_DOOR_CLOSED Reason: The safe door is not open at the beginning or at the end of the encryption (device status CDDOOR__ unequal 0) Measure: Open safe door, repeat job.

2800D300 CDM_KEY_TEST_ERROR Reason: It was not possible to carry out the "CODE TEST" application command correctly. Measure: Start encryption new

2800D400 CDM_ENCRYPT_OFF Reason: As encryption was switched off it is not possible to carry out the key test. Measure: Start encryption new

2800D500 CDM_INVALID_IV Reason: This message occurs in the dialog between the cash-out module and CSCCDM.DLL. Measure: Start encryption new

2800D600 CDM_ENCPRYTION_ERROR Reason: This error occurs in the dialog between the cash-out module and the CSCCDM.DLL. Measure: Start encryption new

Page 474: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

466 June 2004

StWarn:

28000001 CDM_WARNING_GENERAL Reason: Operation possible within limits - photosensor(s) lightly contaminated (CDWS....: = 1) - reject cassette filled min. 80 % (CDWSREJE = N) - Cash provided via alternative denominations (CDWSGENE = A) - evaluate cassette-specific warning (CDWSCA..) Application: Evaluate warning status

28000002 CDM_WARNING_LB Reason: Photosensors dirty Photosensor status in warning status (CDWS....: >= 2) Measure: Clean the photosensor(s) involved System administrator: If necessary, replace the photosensor (with board)

28000003 CDM_WARNING_THRESHOLD_VALUE Reason: This warning is issued with each job!! The message is only issued if a threshold value unequal 0 is set in the parameter table (application program, error analysis, preventive maintenance) Measure: If necessary, reset the threshold value; otherwise, evaluate and carry out specific measures

28000004 CDM_WARNING_EEPROM_MS Reason: EE-PROM measuring station/gauge has almost reached its total number of write cycles. Application: Inform system administrator and ensure that the EE-PROM will be replaced as soon as possible.

28000005 CDM_WARNING_EEPROM_LBAMP Reason: EE-PROM of the photosensor amplifier has almost reached its total number of write cycles. Application: Inform system administrator and ensure that the EE-PROM will be replaced as soon as possible.

Page 475: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 467

28000006 CDM_WARNING_RETRACT Reason: Retract executed, all photosensors free, shutter completely closed.

28000007 CDM_WARNING_MONEY Reason: Time out, removal of cash not performed in the specified time

Page 476: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

468 June 2004

Device status

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDDVCLEN: hhhh; Length device status area no. of follow bytes from ; incl. EOF (0000-FFFF)

CDINSTRU: aa; CD job code Shows last device job processed by cash-out module O# Switch MM control lines O( Start cassette logon (time-independent) O) End time-independent cassette logon O+ Switch customer relay O< Read MM O> Write MM OA Can amount be separated? OB Trigger time lock OC list cassette IHV OD Cassette release OE Create data area in cassette EE-PROM OF Dissolve data area in cassette EE-PROM OG ref. value init (meas. station) OH Write data in cassette EE-PROM OI Read data from cassette EE-PROM OJ Initialize error statistics OK Status request OL Key test OM Separation (currency-dependent) ON Change cassette password 1 OO Change cassette password 2 OP Cash transport OQ Change cassette password 2 via password 1 OR Photosensor amplifier accesses OS Cassette logon (time-dependent) OT Write table of parameters OU Update the cassette capacity data OV Dispensed banknotes OW Separation (currency-independent) OX Self-test OY Key handling OZ Request IV

CDCASNUM: d; No. of cash-out cassettes (1...5)

CDSTATUS: aa; CD status/error specification (see section error messages)

CDSUMBOX: a; Collecting tray E empty F occupied

Page 477: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 469

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CD_TLOCK: a; Time lock available (Y = Yes, N = No)

CDTIMER_: a; Delay running (Y = Yes, N = No)

CDDOOR__: a; Safe door O open C closed and locked R ready for opening

CD_C_REL: a; Customer relay status S switched O not switched N relay not available

CDCAS_IN: dddddd,dddd; YYMMDD,HHMM last cassette install time

CD_SWEDM: a; Software EDM status T transport key missing L line key missing O key available (encryption active)

CDDVINST: aa; Initializing status of cash-out module (byte 0 of the acknowledgement)

CDCLESTA: a; Cash position at power failure 0 No cash found at power-up. The power failure was not during cash transport. 1 Cash was transported into reject box during power-up. No cash accessible by customer. 2 Cash was transported into the retract box at power-up. There was no cash accessible by customer. 3 No cash found by power-up. CASH WAS ACCESSIBLE BY CUSTOMER !!! It was removed during the power failure. 4 Errors during power-up. The cash could not be trans- ported into the reject box. Cash was not accessible to customer. The cause of the error is stored in CDDVINST.5 Error during power-up. The cash could not be trans- ported into the reject box. CASH WAS ACCESSIBLE BY CUSTOMER !!! The cause of the error is stored in CDDVINST.

CD_LBSTA: a; Photosensor status during retract O all photosensors in the output transport are free C minimum 1 photosensor covered

CD_SHSTA: a: Shutter status during retract O Shutter not completely closed C Shutter completely closed

Page 478: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

470 June 2004

Code word Entry Meaning (a=ASCII h=hex d=decimal)

PUT error stack

CDPUTRUN: ddd; Current PUT run

CDPUTINI: dddddd; YYMMDD of error stack initialization

CDPUTNUM: dd; Number of PUT errors (max. 01...16)

CDPUTEnn: ddd,hhhh; nn.errors (01-16):run,error code

EOF

Hardware parameters

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDHPMLEN: hhhh; Length of the hardware parameter Number of following bytes from ; incl. EOF (0000-FFFF)

CDHPTYPE: aaaa; Device type CDOS = cash-out module single-sided AKT_ = TSC 530 CD_F = Front load CD_B = Rear load CD_N = AKT

CDHPCASN: CDHPDEF_:

d; a;

Number of cassettes (1...5) Default direction R = Rear load direction L = Front load direction

R_V_BOOT: R_V_PUT_: R_V_MES_: R_V_OPT_: R_V_REJ_: R_V_CASn: EOF

dddd; dddd; dddd; dddd; dddd; dddd;

Release/version Boot PROM Power-up test Measuring station Photosensor amplifier Reject cassette Cassette (n = 1...5)

Page 479: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 471

Software module

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDSWMLEN: EOF

hhhh; aaaaaaaa.aaa;dddd; hhhh;

Length of the software module list Number of following bytes from ; incl. EOF (0000-FFFF) per software module: Segment name.Extension Release / version number Segment length

Cassette status

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDCASLEN: hhhh; Length cassette status. No. of following bytes after ; incl. EOF (0000-FFFF)

REJESTAT: a; Status see CASnSTAT, exception: C dis. module incl. cassette swapped D pressure cannot be built up are not possible

REJMODNR: dddddddd; Module number

REJSERNR: ddddddd; Serial number

REJCODE_: a; Processing ID N values not up-to-date Y values up-to-date

REJACTNR: dddd; curr. no. of banknotes (single or bundle reject)

REJUNDEF: dddd; No. of undefined banknotes (at power-up or coasting motor)

REJ_INDA: dddddd,dddd; YYMMDD,hhmm last time cassette was inserted

REJ_USNO: ddddddd; Cassette number

Page 480: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

472 June 2004

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CASnSTAT: a; Status C dis. module incl. cassette swapped D pressure cannot be built up F wrong cassette type I internal magnet cannot be addressed K cassette makes contact M cassette missing N default (no./password) missing/wrong P negative password comparison R cassette full inserted S memory cannot be processed

CASnMODn: CASnSERN:

dddddddd; ddddddd;

Module number Serial number

CASnCODE: a; Processing ID Y values up-to-date N values not up-to-date

CASnUSLO: a; Lock flag, User N cassette not locked Y cassette locked by user

CASnHWLO: a; Lock flag, hardware N cassette not locked Y cassette locked due to HW error

CASnCURR: aaa; Currency flag

CASnVALU: dddddddd; Value of banknotes

CASnNRST: CASnACTN:

dddd; dddd;

Number of banknotes at filling Current number of banknotes

CASnREJ_: dddd; Number of banknotes moved from this cassette into the reject cassette (reset each time cassette is inserted!)

CASnLAST: dd; Number of banknotes in the collecting tray at last separation

CASnREJG: ddd; Number of banknotes in the reject cassette at last separation

CASnREJC: dd; Reject no. with double separation (reset each time cassette is inserted!)

CASnINDA: CASnUSNO:

dddddd,dddd; ddddddd;

JJMMTT,HHMM last time cassette was inserted

Page 481: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 473

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CASnCODV: EOF

dddd; Total no. of banknotes of this cassette in device (cassette + transport paths + reject cassette)

n means cassette slot 1-5

Error statistics

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDESLEN_: hhhh; Length error statistics Number of following bytes from ; incl. EOF (0000-FFFF)

CDESDATE: CDESTIME:

dddddd; dddddd;

Date of last initializing (YYMMDD) Time (HHMMSS)

CDESNUDI: ddddd; Number of separation jobs

CDESC1DI: CDESC2DI: CDESC3DI: CDESC4DI: CDESC5DI:

dddddd; dddddd; dddddd; dddddd; dddddd;

Separated banknotes (cassette 1) Separated banknotes (cassette 2) Separated banknotes (cassette 3) Separated banknotes (cassette 4) Separated banknotes (cassette 5)

CDESER01: CDESER02: : : CDESEREE: CDESEREF:

dddd; dddd; ... ... dddd; dddd;

Number of errors (error 01) Number of errors (error 02) ... ... Number of errors (error EE) Number of errors (error EF)

EOF

Page 482: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

474 June 2004

Table of parameters

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDGPLEN_: hhhh; Length of parameter area. Number of following bytes from ; incl. EOF (0000-FFFF)

LIMERRSE: dd; No. of separations to be monitored 00 no monitoring 01..32 no. of separations

ERRLIMSE: dd; Threshold of separation errors 00 no monitoring 01..32 no. of errors

ACTERRSE: dd; Current no. of separation errors

LIMERRTR: dd; No. of transport jobs to be monitored 00 no monitoring 01..32 no. of jobs

ERRLIMTR: dd; Threshold of transport errors 00 no monitoring 01..32 no. of errors

ACTERRTR: dd; Current no. of transport errors

LIMSEPAR: dddddd; Threshold for separation jobs 0 no monitoring 000001..999999 jobs

ACTSEPAR: dddddd; Current no. of separation jobs

DISPALGO: d; Denomination algorithm 0 capacity-dependent 1 priority: high banknote value 2 priority: use of many cassette 3 66% criterion 4 no algorithm (for emulation's)

TO_CUSTM: dddd; Time in seconds until automatic retract 0000 = immediate retract 0001..9999 = wait time in seconds

RETR_CNT: ddd; No. of already performed retracts

RTR_LOCK: a; Separator locked by job "Retract and quit" Y locked N not locked

Page 483: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 475

Code word Entry Meaning (a=ASCII h=hex d=decimal)

per cassette slot

CAnERRSK: dd; No. of separations to be monitored 00 no monitoring 01..32 no. of separations

CAnSKLIM: dd; Threshold of oblique separations from cassette n 00 no monitoring 01..32 no. of separations

CAnACTSK: dd; Current no. of oblique separations

CAnERRDB: dd; Double separation monitoring 00 no monitoring 01..32 no. of separations

CAnDBLIM: dd; Threshold of double separations from cassette n 00 no monitoring 01..32 no. of separations

CAnACTDB: dd; Current no. of double separations from cassette n

CAnSWLO_: a; Software lock Y lock set N no lock

CAnMINI_: dd; Minimum message with xx banknotes 00 no monitoring 01..99 no. of banknotes

EOF

n means cassette slot 1-5

Page 484: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

476 June 2004

Warning status

Code word Entry Meaning (a=ASCII h=hex d=decimal)

CDWSLEN_: hhhh; Length warning field. Number of following bytes from ; incl. EOF (0000-FFFF)

Photosensor status:

CDWS_MES: d; Photosensors of measuring station

CDWS_REJ: d; Control of single reject switch (L 1)

CDWSQT50: CDWSQT51: CDWSQT52: CDWSQT53: CDWSQT54: CDWSQT55: CDWSQT56: CDWSQT57: CDWSQT58: CDWSQT59: CDWSQT60: CDWSQT61: CDWSQT62: CDWSQT63: CDWSQT64: CDWSQT65: CDWSQT66: CDWSQT68:

d; d; d; d; d; d; d; d; d; d; d; d; d; d; d; d; d; d;

Transport path L17 Transport path L18 Transport path L19 Transport path L20 Transport path L21 Transport path L22 Transport path L23 Transport path L24 Transport path L25 Transport path L26 Transport path L27 Transport path L28 Transport path L29 Transport path L30 Transport path L31 Transport path L32 Transport path L33 Transport path L35 d can be: 0 OK 1 slightly contaminated 2 heavily contaminated or receiver too slow 3 faulty

CDWSMnCE: CDWSMnAM: CDWSMnWC: CDWSMnGH:

d; d; d; d;

Cassette empty (n = 1-5) no. of disp. module Dispense sensor Path monitor Banknote height

As soon as a photosensor reaches status 2 or 3, a service call is required. This is reported by the general warning "01 Photosensor warning".

Page 485: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 477

Code word Entry Meaning (a=ASCII h=hex d=decimal)

Modules:

CDWSREJE: a; Reject cassette R = OK, F = full, N = cassette 80 % filled

CDWSGENE: a; general warning N = None, A = Alternative denomination

Cassettes:

CDWSCASR: CDWSCAS1: CDWSCAS2: CDWSCAS3: CDWSCAS4: CDWSCAS5:

dddd; dddd; dddd; dddd; dddd;

Reject cassette slot Cassette slot 1 Cassette slot 2 Cassette slot 3 Cassette slot 4 Cassette slot 5 dddd can be: 00 no status 01 min. quantity reached 02 cassette physically empty 03 cassette logically empty 04 EE-PROM or the cassette nearly filled 06 banknotes in dispensing area 07 ref. value-initializing required 08 EE-PROM not writeable 09 EE-PROM not readable 10 password transfer not possible 11 dispensing photosensor does not become free 12 banknote did not reach dispensing sensor 15 banknote-specific parameter not up-to-date 16 too many sequential single rejects

EOF

Page 486: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

478 June 2004

Two conditions can occur per cassette slot (e.g.: too many single rejects in series and minimum filling level in cassette 3: CDWSCAS3: 1601):

.. ..00 No status Measure: None

..01 Minimum filling level Measure: Fill cassette or lock application

..02 Cassette physically empty Measure: Fill cassette

..03 Current number of banknotes = 0, but at least 1 banknote in the cassette. (This is reset with "Update capacity data") Measure: Update capacity data

..04 EE-PROM of the cassette nearly filled Measure: Call service, replace module

..06 When the banknotes are removed from the cassette, banknotes may show from the closed cassette or be caught in the dispensing rollers. A VISUAL CHECK IS NECESSARY!! Measure: Check the cassette and the dispensing module

..07 Reference value determination necessary for banknote in the measuring station/gauge (This is reset after a successful reference value determination) Measure: Determine reference value

..08 EE-PROM cannot be written to Application: Repeat job Measure: If necessary, have the hardware checked by a technician

Page 487: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 479

..09 EE-PROM cannot be read Application: Repeat job Measure: If necessary, have the hardware checked by a technician

..10 Password transfer not possible Measure: Insert cassette again; if necessary, have the hardware checked by a technician

..11 Dispensing photosensor blocked Measure: Check the cassette or the dispensing module

..12 Banknote does not reach the dispensing photosensor Measure: Check the cassette or the dispensing module

..15 Banknote-specific parameters in the cassette not up-to-date (is reset with "Update capacity data") Measure: Update capacity data

..16 Too many single rejects in series (cassette blocked). CASnHWLO:Y is set when this occurs for the fourth time. Measure: Check the elasticity of the single reject switch or photosensor L20.

Page 488: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

480 June 2004

The messages described above are only set and deleted for certain jobs. This is illus-trated by the following table:

Warning Set with: Deleted with:

..01 Dispensing operation Log on cassette Update capacity data

..02 Dispensing operation (CASnHWLO:Y)

Log on cassette Update capacity data

..03 Dispensing operation (CASnHWLO:Y)

Log on cassette Update capacity data

..04 Release cassette After replacement

..06 Release cassette Log on cassette

..07 Log on cassette Update capacity data (CASnHWLO:Y)

Determine ref. value Log on cassette Update capacity data

..08 First dispensing op. from cas. First trans. in rej. cassette Remove cassette

Log on cassette

..09 Log on cassette Release cassette

Log on cassette

..10 Log on cassette Log on cassette

..11 Dispensing operation (CASnHWLO:Y)

Log on cassette Update capacity data

..12 Dispensing operation CASnHWLO:Y)

Log on cassette Update capacity data

..15 Log on cassette (CASnHWLO:Y)

Log on cassette Update capacity data

..16 Dispensing operation (if 4 times in series, CASnHWLO:Y; is set)

Error-free disp. operation Log on cassette Update capacity data

Page 489: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 481

Position of photosensors

CDM

Page 490: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

482 June 2004

CDM V1

Page 491: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 483

CDM NG

Page 492: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

484 June 2004

CDM NG (ProCash Compact, Frontload)

Page 493: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CDM)

June 2004 485

CDM NG (ProCash Compact, Rearload)

Page 494: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

486 June 2004

Page 495: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 487

Cash-Out Module (CNG) StClass:

STCLASS_OK No error STCLASS_ERROR_CNG Error of the CSCWCNG.DLL

StCode:

2000EF00 CNG_INVALID_RESPONSE Reason: The received V.24 data were not in the expected format. Measure: Check the hardware.

2000EF01 CNG_INVALID_CRC Reason: Invalid CRC (check character) received with encrypted line. Measure: Initialize the line again (by using the function "CscCngEncryption" with the specifications CNG_ENCRYPTION_TEST and/or CNG_ENCRYPTION_INIT_L). Check the hardware.

2000EF02 CNG_INVALID_FRM_AUTO_LOAD Reason: Wrong value for FRM_AUTO_LOAD/LOADER_CTL in Registry with [CSCCNG]. Measure: Check the parameter FRM_AUTO_LOAD/LOADER_CTL in Registry.

2000EF03 CNG_INVALID_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in Registry with [CSCCNG]. Measure: Check the parameters LED, LED2, LED_FLASH, LED2_FLASH and LED_FREQ in file Registry.

Page 496: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

488 June 2004

2000EF04 CNG_FIRMWARE_INCOMPLETE Reason: Firmware loading could not be completed. A possible cause is that it may have been attempted to load a firmware version that was not suitable (e.g. a CNG firmware into a ProCash CRS). Measure: Check the configuration. Load a firmware released for the self-service system.

2000EF05 CNG_INVALID_CURRENCY_FILES Reason: Wrong value for the keywords CURRENCY_FILES or FILE#x in Registry. Measure: Check the parameter for the keywords CURRENCY_FILES and FILE#x in Registry.

2000EF06 CNG_INVALID_CUR_FILE_FORMAT Reason: Wrong structure/contents for the Currency Data Files. Measure: Check the structure/contents of the Currency Data Files.

2000EF07 CNG_INVALID_RECOVERY Reason: Wrong value for RECOVERY in Registry with [CSCCNG]. Measure: Check the parameter RECOVERY in Registry.

2000EF08 CNG_INVALID_VARIANT Reason: Wrong value for VARIANT in Registry with [CSCCNG]. Measure: Check the parameter VARIANT in Registry.

2000EF09 CNG_INVALID_BEB_STATISTICS Reason: Wrong value for BEB_STATISTIC or BEB_STATISTICS_ROOT in Registry with [CSCCNG]. Measure: Check the parameter BEV_STATISTICS or BEB_STATISTICS_ROOT in Registry.

Page 497: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

June 2004 489

2000EF0A CNG_INSUFFICIENT_MODULES Reason: Insufficient number of currency modules installed in CRS. Application: Application specific behaviour. Check the configuration of CNG.

2000EF0B CNG_INVALID_CHECK_MODULES Reason: Wrong value for CHECK_MODULES in Registry with [CSCCNG]. Measure: Check the parameter CHECK_MODULES in Registry.

2000EF0C CNG_INVALID_DISPENSEIN_TRACE Reason: Wrong value for DISPENSEIN_TRACE in Registry with [CSCCNG]. Measure: Check the parameter DISPENSEIN_TRACE in Registry.

2000EF0D CNG_INVALID_CURRENCY_AUTOLOAD Reason: Wrong value for CY_AUTOLOAD in Registry with [CSCCNG]. Measure: Check the parameter CY_AUTOLOAD in Registry.

2000EF0E CNG_INVALID_CURRENCY_MAP_NOTES Reason: Wrong value for CY_MAP_NOTES in Registry with [CSCCNG]. Measure: Check the parameter CY_MAP_NOTES in Registry.

2000EF0F CNG_INVALID_CONFIG_BACKUP Reason: Wrong value for CONFIG_BACKUP in Registry with [CSCCNG]. This is an internal keyvalue used by the DH. This value is not to be changed by anyone. A possible cause is that this value was changed manually or the system was interrupted during download of currency files (power off). Measure: Check the parameter CONFIG_BACKUP in Registry.

Page 498: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

490 June 2004

2000EF10 CNG_INVALID_LOADER_CTL Reason: Wrong value for LOADER_CTL in registry with [CSCCNG] or [CSCCNG/BIM_FRM]. Measure: Check the parameter LOADER_CTL in registry.

2000EF11 CNG_INVALID_BIM_TYPE Reason: Unknown BIM type detected. Measure: Check the configuration.

2000EF12 CNG_OPEN_CURRENCY_FILE_FAILED Reason: A currency file could not be opened. Measure: Check the existence/contents of the currency files.

2000EF13 CNG_READ_CURRENCY_FILE_FAILED Reason: A currency file could not be read. Measure: Check the contents of the currency files.

2000EF14 CNG_OPEN_FIRMWARE_FILE_FAILED Reason: A firmware file could not be opened. Measure: Check the existence/contents of the firmware files.

2000EF15 CNG_READ_FIRMWARE_FILE_FAILED Reason: A firmware file could not be read. Measure: Check the contents of the firmware files.

Page 499: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

June 2004 491

2000EF16 CNG_INVALID_FRM_FILE_FORMAT Reason: A firmware file for the controller or one of the subcomponents is useless. Either the firmware file does not fit the component or the structure of the firmware file is damaged. Measure: Check the contents of the firmware files and the configuration.

2800F000 CNG_FRM_SW_MISSING Reason: The firmware is not loaded in the CDM NG. Measure: Load the firmware with the function "CscCngInit".

2800F001 CNG_FRM_SYNTAX Reason: The parameters of the command have a wrong syntax. Application: Check the parameters of the last API function call.

2800F002 CNG_FRM_DEVICE_NOT_READY Reason: One of the locks is active or an error occurred that requires a corrective operator action. Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F003 CNG_FRM_ERROR Reason: An error occurred during the execution of the command. Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F004 CNG_FRM_DOOR_NOT_OPEN Reason: The safe door must be open for the execution of the actual command (switching the encryption on/off). Measure: Open the safe door.

Page 500: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

492 June 2004

2800F005 CNG_FRM_CONTEXT Reason: The command cannot be executed at this point of time or a special HW component is missing or not configured. Application: Check the status to see, if this command can be executed. Measure: Check the hardware and the configuration.

2800F006 CNG_FRM_ERROR_DECRYPTION Reason: The CDM NG recognized a problem with the encryption and a first try to resynchronize the line was not successful. Perhaps the transport key is not valid. Application: Try again to resynchronize the line by using the function "CscCngEncryption" with the specifications CNG_ENCRYPTION_TEST and/or CNG_ENCRYPTION_INIT_L. Perhaps the transport key must be loaded again. Measure: Check the line.

2800F007 CNG_FRM_MONEY_NOT_REMOVED Reason: Command has timed out. Application: Application specific behaviour. Repeat the command if necessary.

2800F008 CNG_FRM_SCOP Reason: - HASH value of Firmware not correct - certificate not correct - amount to be dispensed greater than allowed by certificate - currency of certificate and cassettes different Measure: Check firmware on disk. Call program support.

Page 501: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

June 2004 493

2800F012 CNG_FRM_ACCESS_DEVICE_NOT_READY Reason: This is the same error as CNG_FRM_DEVICE_NOT_READY with the exception that the banknotes were accessible to the customer (according to the <MON> flag). Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F013 CNG_FRM_ACCESS_ERROR Reason: This is the same error as CNG_FRM_ERROR with the exception that the banknotes were accessible to the customer (according to the <MON> flag). Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F015 CNG_FRM_ACCESS_CONTEXT Reason: This is the same error as CNG_FRM_CONTEXT with the exception that the banknotes were accessible to the customer (according to the <MON> flag). Measure: Check the hardware and the configuration.

StWarn:

2000E002 CNG_NO_ACTUAL_FIRMWARE Reason: The firmware on the disk is newer than the software presently loaded in the CDM NG. Application: If necessary load the firmware by using the API function "CscCngInit".

2000E003 CNG_NO_FIRMWARE Reason: There is no firmware loaded in the CDM NG. Application: Load the firmware by using the API function "CscCngInit".

Page 502: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Out Module (CNG)

494 June 2004

2000E004 CNG_WARN_LED Reason: The device handler was configured to switch LEDs when waiting for the removal of banknotes. An error occurred when accessing the SEL DH to switch the LEDs. Measure: Check the configuration of CNG and SEL device handler.

2000E006 CNG_WARN_INSUFFICIENT_MODULES Reason: Number of currency modules in the CRS is insufficient; is less than the number of configured currency files. Application: Application specific behaviour. Check the configuration of CNG.

2800E000 CNG_WARN_MONEY_NOT_REMOVED Reason: This is a status that tells the application that no (or not all) banknotes have been taken by the customer. Application: Application specific behaviour.

2800E001 CNG_WARN_MONEY_REMOVED Reason: This is a status that tells the application that all banknotes have been taken by the customer. Application: Application specific behaviour.

2800E005 CNG_WARN_ENTRY_HANDLING Reason: Input tray operator error (e.g. input tray closed without input of banknotes). Application: Application specific behaviour. Repeat the last command if necessary.

2800E007 CNG_WARN_PROTOCOL_RETRY Reason: An command could not be executed after 3 repetitions. Application: Application specific behaviour. Repeat the command if necessary.

Page 503: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 495

CNG: extended error codes 20001000 CNG_EXT_2X0_CONTEXT_ERROR

Reason: Context error Measure: Evaluate the system and cassette status. If necessary inform System administrator.

20001001 CNG_EXT_2X0_SW_DEFECT Reason: No response from the CDM (software) Measure: Restart system. If necessary inform System administrator.

20001010 CNG_EXT_2X0_CONTR_DEFECT Reason: CDM electronics faulty Measure: Replace controller

20001011 CNG_EXT_2X0_NO_FIRMWARE Reason: Software missing in the CDM Application: Load the firmware with the API function "CscCngInit". Measure: Put the application again into operation. If necessary inform System administrator.

20001012 CNG_EXT_2X0_SAFETY_CIRC_OPEN Reason: CDM has not been inserted completely Measure: Insert the CDM into the safe. If necessary inform System administrator.

Page 504: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

496 June 2004

20001013 CNG_EXT_2X0_DLOC_YES Reason: The maximal number of retracts has been reached Application: Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK". Measure: Remove the customer money from the retract box and transport path using operator function.

20001014 CNG_EXT_2X0_CONFIG_NO_CAS Reason: Minimum configuration missing. In order to operate, the CDM requires at least one reject-/retract cassette and one cash-out cassette. Measure: Insert the reject cassette and log on using operator function.

20001018 CNG_EXT_2X0_JAM_DISPENSE Reason: Note jam during dispensing Cash not accessible by customer Measure: Check the note path from the cassettes to the collecting tray. If necessary inform System administrator.

20001019 CNG_EXT_2X0_JAM_OUTPUT_TRANS Reason: Money jam in the output transport Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20001020 CNG_EXT_2X0_SINGLE_REJ_DEFECT Reason: Single reject switch faulty/blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 505: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 497

20001021 CNG_EXT_2X0_MS_DEFECT Reason: Measuring station faulty Measure: Inform Service.

20001022 CNG_EXT_2X0_LBAMP_DEFECT Reason: Photosensor amplifier faulty or photosensor initialization not successful. Measure: Check the note paths using operator function. If necessary inform System administrator.

20001023 CNG_EXT_2X0_RESET_RW_DEFECT Reason: Bundle reject switch faulty/blocked Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20001024 CNG_EXT_2X0_RESET_RR_DEFECT Reason: Reject/retract drive faulty/blocked Measure: Check the reject cassette using operator function. If necessary inform System administrator.

20001025 CNG_EXT_2X0_VMOTOR_DEFECT Reason: Dispensing drive faulty/blocked BBA UT: CDM has not been inserted completely Measure: Check the note paths using operator function. If necessary inform System administrator BBA UT: Bring the CDM into the cash-out position in the safe.

20001026 CNG_EXT_2X0_COL_TRAY_DEFECT Reason: Switching dispensing/transport or vertical transport faulty/blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 506: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

498 June 2004

20001028 CNG_EXT_2X0_TRANS_SHUT_DEFECT Reason: Shutter cannot be opened/defect SHUT=C, MON=N -> shutter can not open, cash not accessible by customer SHUT=U, MON=P -> shutter undefined, cash accessible by customer SHUT=U, MON=W -> shutter undefined, cash was removed SHUT=U, MON=R -> shutter undefined, cash was retracted Measure: Check shutter, if necessary inform System administrator.

20001029 CNG_EXT_2X0_OFFER_LB_L26_UE_COV Reason: Manipulation during delivery Measure: Check shutter, if necessary inform System administrator.

20001031 CNG_EXT_2X0_CAS1_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 1) Measure: Check cassette 1, if necessary inform System administrator.

20001032 CNG_EXT_2X0_CAS2_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 2) Measure: Check cassette 2, if necessary inform System administrator.

20001033 CNG_EXT_2X0_CAS3_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 3) Measure: Check cassette 3, if necessary inform System administrator.

20001034 CNG_EXT_2X0_CAS4_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 4) Measure: Check cassette 4, if necessary inform System administrator.

Page 507: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 499

20001035 CNG_EXT_2X0_CAS5_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 5) Measure: Check cassette 5, if necessary inform System administrator.

20001036 CNG_EXT_2X0_CAS6_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 6) Measure: Check cassette 6, if necessary inform System administrator.

20001041 CNG_EXT_2X0_CAS1_NO_SEPARATION Reason: Note extraction impossible (cassette 1) or incorrect note pressure while inserting the cassette. Measure: Check cassette 1, if necessary inform System administrator.

20001042 CNG_EXT_2X0_CAS2_NO_SEPARATION Reason: Note extraction impossible (cassette 2) or incorrect note pressure while inserting the cassette. Measure: Check cassette 2, if necessary inform System administrator.

20001043 CNG_EXT_2X0_CAS3_NO_SEPARATION Reason: Note extraction impossible (cassette 3) or incorrect note pressure while inserting the cassette. Measure: Check cassette 3, if necessary inform System administrator.

20001044 CNG_EXT_2X0_CAS4_NO_SEPARATION Reason: Note extraction impossible (cassette 4) or incorrect note pressure while inserting the cassette. Measure: Check cassette 4, if necessary inform System administrator.

Page 508: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

500 June 2004

20001045 CNG_EXT_2X0_CAS5_NO_SEPARATION Reason: Note extraction impossible (cassette 5) or incorrect note pressure while inserting the cassette. Measure: Check cassette 5, if necessary inform System administrator.

20001046 CNG_EXT_2X0_CAS6_NO_SEPARATION Reason: Note extraction impossible (cassette 6) or incorrect note pressure while inserting the cassette. Measure: Check cassette 6, if necessary inform System administrator.

20001051 CNG_EXT_2X0_CAS1_MANY_BAD_NOTES Reason: Too many bad notes (cassette 1). Measure: Inform system administrator.

20001052 CNG_EXT_2X0_CAS2_MANY_BAD_NOTES Reason: Too many bad notes (cassette 2). Measure: Inform system administrator.

20001053 CNG_EXT_2X0_CAS3_MANY_BAD_NOTES Reason: Too many bad notes (cassette 3). Measure: Inform system administrator.

20001054 CNG_EXT_2X0_CAS4_MANY_BAD_NOTES Reason: Too many bad notes (cassette 4). Measure: Inform system administrator.

Page 509: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 501

20001055 CNG_EXT_2X0_CAS5_MANY_BAD_NOTES Reason: Too many bad notes (cassette 5). Measure: Inform system administrator.

20001056 CNG_EXT_2X0_CAS6_MANY_BAD_NOTES Reason: Too many bad notes (cassette 6). Measure: Inform system administrator.

20001061 CNG_EXT_2X0_CAS1_EEPROM_ERR Reason: Cassette 1 faulty. Measure: Inform service.

20001062 CNG_EXT_2X0_CAS2_EEPROM_ERR Reason: Cassette 2 faulty. Measure: Inform Service.

20001063 CNG_EXT_2X0_CAS3_EEPROM_ERR Reason: Cassette 3 faulty. Measure: Inform Service.

20001064 CNG_EXT_2X0_CAS4_EEPROM_ERR Reason: Cassette 4 faulty. Measure: Inform Service.

Page 510: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

502 June 2004

20001065 CNG_EXT_2X0_CAS5_EEPROM_ERR Reason: Cassette 5 faulty. Measure: Inform Service.

20001066 CNG_EXT_2X0_CAS6_EEPROM_ERR Reason: Cassette 6 faulty. Measure: Inform Service.

20001070 CNG_EXT_2X0_CONTAM_MS Reason: Photosensors measuring station soiled. Measure: Inform System administrator.

20001071 CNG_EXT_2X0_DEDUC_FLAG_LAM1 Reason: Dispenser sensor soiled (cassette 1) or pressure sensor faulty. Measure: Inform system administrator.

20001072 CNG_EXT_2X0_DEDUC_FLAG_LAM2 Reason: Dispenser sensor soiled (cassette 2) or pressure sensor faulty. Measure: Inform system administrator.

20001073 CNG_EXT_2X0_DEDUC_FLAG_LAM3 Reason: Dispenser sensor soiled (cassette 3) or pressure sensor faulty. Measure: Inform system administrator.

Page 511: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 503

20001074 CNG_EXT_2X0_DEDUC_FLAG_LAM4 Reason: Dispenser sensor soiled (cassette 4) or pressure sensor faulty. Measure: Inform system administrator.

20001075 CNG_EXT_2X0_DEDUC_FLAG_LAM5 Reason: Dispenser sensor soiled (cassette 5) or pressure sensor faulty. Measure: Inform system administrator.

20001076 CNG_EXT_2X0_DEDUC_FLAG_LAM6 Reason: Dispenser sensor soiled (cassette 6) or pressure sensor faulty. Measure: Inform system administrator.

20001081 CNG_EXT_2X0_EMPTY_FLAG_KL1 Reason: Empty sensor soiled (cassette 1). Measure: Inform system administrator.

20001082 CNG_EXT_2X0_EMPTY_FLAG_KL2 Reason: Empty sensor soiled (cassette 2). Measure: Inform system administrator.

20001083 CNG_EXT_2X0_EMPTY_FLAG_KL3 Reason: Empty sensor soiled (cassette 3). Measure: Inform system administrator.

Page 512: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

504 June 2004

20001084 CNG_EXT_2X0_EMPTY_FLAG_KL4 Reason: Empty sensor soiled (cassette 4). Measure: Inform system administrator.

20001085 CNG_EXT_2X0_EMPTY_FLAG_KL5 Reason: Empty sensor soiled (cassette 5). Measure: Inform system administrator.

20001086 CNG_EXT_2X0_EMPTY_FLAG_KL6 Reason: Empty sensor soiled (cassette 6). Measure: Inform system administrator.

20001090 CNG_EXT_2X0_CONTAM_LB1 Reason: Photosensor L1 soiled. Measure: Inform system administrator.

20001091 CNG_EXT_2X0_CONTAM_LB18 Reason: Photosensor L18 soiled. Measure: Inform system administrator.

20001093 CNG_EXT_2X0_CONTAM_LB21 Reason: Photosensor L21 soiled. Measure: Inform system administrator.

Page 513: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 505

20001098 CNG_EXT_2X0_CONTAM_LB27 Reason: Photosensor L27 soiled. Measure: Inform system administrator.

20001099 CNG_EXT_2X0_CONTAM_LB28 Reason: Photosensor L28 soiled. Measure: Inform system administrator.

20001800 CNG_EXT_CMD_CONTEXT_ERROR Reason: Context error Measure: Evaluate the system and cassette status. If necessary inform System administrator.

20001801 CNG_EXT_CMD_SW_DEFECT Reason: No response from the CDM (software) Measure: Start system again, if necessary inform System administrator.

20001805 CNG_EXT_CMD_CHIPCONT_COMM_ERR Reason: Communication problem with the chip card controller. Measure: Replace the chip card controller.

20001806 CNG_EXT_CMD_CHIPCARD_COMM_ERR Reason: Communication problem with the chip card. Measure: Check / replace the chip card.

Page 514: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

506 June 2004

20001807 CNG_EXT_CMD_HW_NOT_CONFIRMED Reason: HW configuration does not confirm. Application: Configuration after examination by command confirm.

20001808 CNG_EXT_CMD_IDENT_PROM_ERROR Reason: Communication problem with the EE-PROM collector. Measure: Check / replace EE-PROM.

20001809 CNG_EXT_CMD_SERVICE_SWITCH_OPEN Reason: Service switch is open Measure: Push CMD-V4 completely into safe. Inform service if necessary.

20001810 CNG_EXT_CMD_CONTR_DEFECT Reason: CMD electronics faulty. Measure: Replace controller

20001811 CNG_EXT_CMD_NO_FIRMWARE Reason: Software missing in the CMD Application: Load the firmware with the API function "CscCngInit". Measure: Put the application again into operation. If necessary inform System administrator.

20001812 CNG_EXT_CMD_SAFETY_CIRC_OPEN Reason: CMD has not been inserted completely Measure: Insert the CMD into the safe. If necessary inform System administrator.

Page 515: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 507

20001813 CNG_EXT_CMD_DLOC_YES Reason: The maximal number of retracts has been reached Application: Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK". Measure: Remove the customer money from the retract box and transport path using operator function.

20001814 CNG_EXT_CMD_CONFIG_NO_CAS Reason: Minimum configuration missing. In order to operate, the CDM requires at least one reject-/retract cassette and one cash-out cassette. Measure: Insert the cassettes and log on using operator function.

20001817 CNG_EXT_CMD_OUTPUT_TRANS_DEFECT Reason: Gripper belt drive faulty. Measure: Replace output transport or controller

20001818 CNG_EXT_CMD_JAM_DISPENSE Reason: Note jam during dispensing Cash not accessible by customer Measure: Check the note path from the cassettes to the collecting tray. If necessary inform System administrator.

20001819 CNG_EXT_CMD_NOTE_TRANS_BLOCKED Reason: Gripper transport defective / blocked Measure: Eliminate the blockade using operator function, if necessary inform system administrator.

Page 516: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

508 June 2004

20001820 CNG_EXT_CMD_SINGLE_REJ_DEFECT Reason: Single reject switch faulty/blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

20001821 CNG_EXT_CMD_MS_DEFECT Reason: Measuring station faulty Measure: Inform service.

20001822 CNG_EXT_CMD_LBAMP_DEFECT Reason: Photosensor amplifier faulty or photosensor initialization not successful. Measure: Check the note paths using operator function. If necessary inform System administrator.

20001823 CNG_EXT_CMD_TURNTABLE_DEFECT Reason: Circle switch faulty/blocked Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20001824 CNG_EXT_CMD_RESET_RR_DEFECT Reason: Reject/retract drive faulty/blocked Measure: Check the reject cassette using operator function. If necessary inform System administrator.

20001825 CNG_EXT_CMD_VMOTOR_DEFECT Reason: Dispensing drive faulty/blocked BBA UT: CMD has not been inserted completely Measure: Check the note paths using operator function. If necessary inform System administrator BBA UT: Bring the CMD into the cash-out position in the safe.

Page 517: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 509

20001826 CNG_EXT_CMD_STACKER_DEFECT Reason: Stacker drive faulty /blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

20001828 CNG_EXT_CMD_TRANS_SHUT_DEFECT Reason: Shutter cannot be open/close SHUT=C, MON=N -> shutter cannot be open, cash not accessible by customer SHUT=U, MON=P -> shutter undefined, cash is accessible by customer SHUT=U, MON=W -> shutter undefined, cash has been withdrawn SHUT=U, MON=P -> shutter undefined, cash accessible by customer Measure: Check shutter, if necessary inform System administrator.

20001829 CNG_EXT_CMD_PS_OFFER_COV Reason: Manipulation during delivery Measure: Check shutter, if necessary inform System administrator.

20001831 CNG_EXT_CMD_CAS1_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 1 Measure: Check cassette 1, if necessary inform System administrator.

20001832 CNG_EXT_CMD_CAS2_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 2 Measure: Check cassette 2, if necessary inform System administrator.

20001833 CNG_EXT_CMD_CAS3_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 3 Measure: Check cassette 3, if necessary inform System administrator.

Page 518: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

510 June 2004

20001834 CNG_EXT_CMD_CAS4_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 4 Measure: Check cassette 4, if necessary inform System administrator.

20001835 CNG_EXT_CMD_CAS5_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 5 Measure: Check cassette 5, if necessary inform System administrator.

20001836 CNG_EXT_CMD_CAS6_MANY_REJECTS Reason: Too many rejects during dispensing from cassette 6 Measure: Check cassette 6, if necessary inform System administrator.

20001841 CNG_EXT_CMD_CAS1_NO_SEPARATION Reason: Note extraction impossible (cassette 1) or incorrect note pressure while inserting the cassette. Measure: Check cassette 1, if necessary inform System administrator.

20001842 CNG_EXT_CMD_CAS2_NO_SEPARATION Reason: Note extraction impossible (cassette 2) or incorrect note pressure while inserting the cassette. Measure: Check cassette 2, if necessary inform System administrator.

20001843 CNG_EXT_CMD_CAS3_NO_SEPARATION Reason: Note extraction impossible (cassette 3) or incorrect note pressure while inserting the cassette. Measure: Check cassette 3, if necessary inform System administrator.

Page 519: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 511

20001844 CNG_EXT_CMD_CAS4_NO_SEPARATION Reason: Note extraction impossible (cassette 4) or incorrect note pressure while inserting the cassette. Measure: Check cassette 4, if necessary inform System administrator.

20001845 CNG_EXT_CMD_CAS5_NO_SEPARATION Reason: Note extraction impossible (cassette 5) or incorrect note pressure while inserting the cassette. Measure: Check cassette 5, if necessary inform System administrator.

20001846 CNG_EXT_CMD_CAS6_NO_SEPARATION Reason: Note extraction impossible (cassette 6) or incorrect note pressure while inserting the cassette. Measure: Check cassette 6, if necessary inform System administrator.

20001851 CNG_EXT_CMD_CAS1_MANY_BAD_NOTES Reason: Too many bad notes (cassette 1). Measure: Inform system administrator.

20001852 CNG_EXT_CMD_CAS2_MANY_BAD_NOTES Reason: Too many bad notes (cassette 2). Measure: Inform system administrator.

20001853 CNG_EXT_CMD_CAS3_MANY_BAD_NOTES Reason: Too many bad notes (cassette 3). Measure: Inform system administrator.

Page 520: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

512 June 2004

20001854 CNG_EXT_CMD_CAS4_MANY_BAD_NOTES Reason: Too many bad notes (cassette 4). Measure: Inform system administrator.

20001855 CNG_EXT_CMD_CAS5_MANY_BAD_NOTES Reason: Too many bad notes (cassette 5). Measure: Inform system administrator.

20001856 CNG_EXT_CMD_CAS6_MANY_BAD_NOTES Reason: Too many bad notes (cassette 6). Measure: Inform system administrator.

20001861 CNG_EXT_CMD_CAS1_EEPROM_ERR Reason: Cassette 1 faulty. Measure: Inform service.

20001862 CNG_EXT_CMD_CAS2_EEPROM_ERR Reason: Cassette 2 faulty. Measure: Inform Service.

20001863 CNG_EXT_CMD_CAS3_EEPROM_ERR Reason: Cassette 3 faulty. Measure: Inform Service.

Page 521: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 513

20001864 CNG_EXT_CMD_CAS4_EEPROM_ERR Reason: Cassette 4 faulty. Measure: Inform Service.

20001865 CNG_EXT_CMD_CAS5_EEPROM_ERR Reason: Cassette 5 faulty. Measure: Inform Service.

20001866 CNG_EXT_CMD_CAS6_EEPROM_ERR Reason: Cassette 6 faulty. Measure: Inform Service.

20001870 CNG_EXT_CMD_MS_defect Reason: Photosensors measuring station soiled. Measure: Inform system administrator.

20001871 CNG_EXT_CMD_DEDUC_FLAG_LAM1 Reason: Dispenser sensor soiled (cassette 1) or pressure sensor faulty. Measure: Inform system administrator.

20001872 CNG_EXT_CMD_DEDUC_FLAG_LAM2 Reason: Dispenser sensor soiled (cassette 2) or pressure sensor faulty. Measure: Inform system administrator.

Page 522: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

514 June 2004

20001873 CNG_EXT_CMD_DEDUC_FLAG_LAM3 Reason: Dispenser sensor soiled (cassette 3) or pressure sensor faulty. Measure: Inform system administrator.

20001874 CNG_EXT_CMD_DEDUC_FLAG_LAM4 Reason: Dispenser sensor soiled (cassette 4) or pressure sensor faulty. Measure: Inform system administrator.

20001875 CNG_EXT_CMD_DEDUC_FLAG_LAM5 Reason: Dispenser sensor soiled (cassette 5) or pressure sensor faulty. Measure: Inform system administrator.

20001876 CNG_EXT_CMD_DEDUC_FLAG_LAM6 Reason: Dispenser sensor soiled (cassette 6) or pressure sensor faulty. Measure: Inform system administrator.

20001881 CNG_EXT_CMD_EMPTY_FLAG_KL1 Reason: Empty sensor soiled (cassette 1). Measure: Inform system administrator.

20001882 CNG_EXT_CMD_EMPTY_FLAG_KL2 Reason: Empty sensor soiled (cassette 2). Measure: Inform system administrator.

Page 523: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 515

20001883 CNG_EXT_CMD_EMPTY_FLAG_KL3 Reason: Empty sensor soiled (cassette 3). Measure: Inform system administrator.

20001884 CNG_EXT_CMD_EMPTY_FLAG_KL4 Reason: Empty sensor soiled (cassette 4). Measure: Inform system administrator.

20001885 CNG_EXT_CMD_EMPTY_FLAG_KL5 Reason: Empty sensor soiled (cassette 5). Measure: Inform system administrator.

20001886 CNG_EXT_CMD_EMPTY_FLAG_KL6 Reason: Empty sensor soiled (cassette 6). Measure: Inform system administrator.

20001890 CNG_EXT_CMD_CONTAM_LB1 Reason: Photosensor L1 soiled. Measure: Inform system administrator.

20001891 CNG_EXT_CMD_CONTAM_LB18 Reason: Photosensor L18 soiled. Measure: Inform system administrator.

Page 524: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

516 June 2004

20001893 CNG_EXT_CMD_CONTAM_LB2 Reason: Control tray single reject L2 soiled. Measure: Inform system administrator.

20001895 CNG_EXT_CMD_CONTAM_LB26_LB27 Reason: Withdrawal photosensor soiled. Measure: Inform system administrator.

2000189A CNG_EXT_CMD_CONTAM_LB28_LB29 Reason: Photosensor bundle rear edge control (presenter) soiled. Measure: Inform system administrator.

2000189D CNG_EXT_CMD_CONTAM_LB2_REJECT_BOX Reason: Photosensor reject box soiled. Measure: Inform system administrator.

2000189E CNG_EXT_CMD_CONTAM_LB3_REJECT_BOX Reason: Photosensor reject box soiled. Measure: Inform system administrator.

20003000 CNG_EXT_CRS_CONTEXT_ERROR Reason: SW or handling error. Measure: Evaluate the system and cassette status. If necessary inform System administrator.

Page 525: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 517

20003010 CNG_EXT_CRS_SW_DEFEKT Reason: No response from the CRS (software). Measure: Start system again, if necessary inform system administrator.

20003016 CNG_EXT_CRS_FRM_DEFEKT Reason: CDM electronic faulty. Measure: Replace controller.

20003020 CNG_EXT_CRS_COMM_INT_ERROR Reason: Communication problem master <==> slave Measure: Start system again, if necessary inform system administrator.

20003025 CNG_EXT_CRS_SUBCONTR_NO_FRM Reason: Communication problem master <==> slave Measure: Start system again, if necessary inform system administrator.

20003100 CNG_EXT_CRS_SUBCONTR_DEFEKT Reason: Controller safe module faulty. Measure: Replace controller.

20003101 CNG_EXT_CRS_SUBCONTR_NO_BOOTER Reason: Cash controller no booter / faulty Measure: Replace controller.

Page 526: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

518 June 2004

20003105 CNG_EXT_CRS_CONTR_DEFEKT Reason: Counter controller faulty. Measure: Replace controller.

20003106 CNG_EXT_CRS_CONTR_NO_BOOTER Reason: Counter controller no booter / faulty Measure: Replace controller.

20003110 CNG_EXT_CRS_NO_SW Reason: Software missing. Measure: Start system again, if necessary inform system administrator.

20003120 CNG_EXT_CRS_SAFE_SAFETYCIRC_OPEN Reason: Safe module has not been inserted completely Measure: Insert the safe module into the safe. If necessary inform System administrator.

20003125 CNG_EXT_COUNT_SAFETYCIRC_OPEN Reason: Front or rear door not closed Counter module has not been inserted completely Measure: Close the front or rear door. Insert the counter module. If necessary inform system administrator.

Page 527: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 519

20003135 CNG_EXT_CRS_DLOC_YES Reason: The maximal number of retracts has been reached Application: Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK". Measure: Remove the money from the retract box and transport path using operator function.

20003136 CNG_EXT_CRS_ILOC_YES Reason: Device lock after jam in counter area Application: Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK". Measure: Remove the notes from the transport path in the counter area using operator function "check note paths" and reset device lock.

20003137 CNG_EXT_CRS_L3_BOX_FULL Reason: Cash-in box for L3 notes is full. Application: Execute RESET after empty and release of the L3 box. Measure: Empty and release the L3 box.

20003140 CNG_EXT_CRS_CONF_NO_CASHOUT_CAS Reason: Minimum configuration for cash-out missing. Measure: Insert at least one cash-out cassette and the reject cassette (all box) and log on using operator function.

20003145 CNG_EXT_CRS_CONF_NO_CASHIN_CASS Reason: Minimum configuration for cash-in missing. Measure: Insert at least the cash-in box 1 (all box) and the retract cassette and log on using operator function.

Page 528: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

520 June 2004

20003146 CNG_EXT_CONF_AUTHENTICATOR_MISS Reason: Minimum configuration of banknote identification module is missing. Application: Load the currency data files with the API function "CscCngBim - CNG_BIM_LOAD_MON". Measure: Check the banknote identification module configuration load currency data file(s) if necessary.

20003170 CNG_EXT_JAM_CASHIN_TRANSPNT_CASS Reason: Note jam "safe delivery <==> cash-in cassettes" during cash-in Measure: Eliminate money jam "safe delivery <==> cash-in cassettes" using operator function "check note paths". If necessary inform System administrator.

20003171 CNG_EXT_JAM_CASHIN_TRANSPNT_DRUM Reason: Money jam "safe delivery <==> roller" during cash-in. Measure: Eliminate money jam "safe delivery <==> roller" using operator function "check note paths". If necessary inform System administrator.

20003175 CNG_EXT_JAM_CASHIN_IN_OUT_TRAY Reason: Money jam "filling try <==> cash-out try" during cash-in. Measure: Eliminate money jam "filling tray <==> cash-out tray" using operator function "check note paths". If necessary inform System administrator.

20003176 CNG_EXT_JAM_CASHIN_TRAY_ESCROW Reason: Money jam "filling try <==> escrow" during cash-in. Measure: Eliminate money jam "filling tray <==> escrow" using operator function "check note paths". If necessary inform System administrator.

Page 529: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 521

20003178 CNG_EXT_JAM_CASHIN_ESCROW_OUT Reason: Money jam "escrow <==> cash-out tray" during reject/retract. Measure: Eliminate money jam "escrow <==> cash-out tray" using operator function "check note paths". If necessary inform System administrator.

20003179 CNG_EXT_JAM_IN_ESCROW_TRANSPNT Reason: Money jam "escrow <==> safe delivery" during cash-in. Measure: Eliminate money jam "escrow <==> safe delivery" using operator function "check note paths". If necessary inform System administrator.

20003180 CNG_EXT_CASS_TRANSPORT Reason: Money jam "cash-out cassette <==> safe delivery" during cash-out Money jam when emptying the drums (money jam in front of the cassette) Measure: Eliminate money jam "cash-out cassette <==> safe delivery" or "drum storage <==> cash-in cassette" using operator function "check note paths". If HSK1 is used ensure that the cable is connected. Inform system administrator if necessary.

20003181 CNG_EXT_JAM_OUT_DRUM_TRANSPNT Reason: Money jam "roller <==> safe delivery" during cash-out. Measure: Eliminate money jam "roller <==> safe delivery" using operator function "check note paths". If necessary inform System administrator.

20003182 CNG_EXT_JAM_OUT_TRANSPNT_REJCASS Reason: Money jam "safe delivery <==> reject/retract cassette" during reject/retract. Measure: Eliminate money jam "safe delivery <==> reject/retract cassette" using operator function "check note paths". If necessary inform System administrator.

Page 530: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

522 June 2004

20003185 CNG_EXT_JAM_OUT_TRANSPNT_OUTTRAY Reason: Money jam "safe delivery <==> cash-out tray" during cash-out. Measure: Eliminate money jam "safe delivery <==> cash-out tray" using operator function "check note paths". If necessary inform System administrator.

20003186 CNG_EXT_JAM_REJ_OUTTRAY_TRANSPNT Reason: Money jam "cash-out tray <==> safe delivery" during bundle reject. Measure: Eliminate money jam "cash-out tray <==> safe delivery" using operator function "check note paths". If necessary inform System administrator.

20003187 CNG_EXT_JAM_RET_OUTTRAY_TRANSPNT Reason: Money jam "cash-out tray <==> safe delivery" during retract. Measure: Eliminate money jam "cash-out tray <==> safe delivery" using operator function "check note paths". If necessary inform System administrator

20003200 CNG_EXT_DEFLECTOR_DEF_INBOX_1 Reason: Switch cash-in cassette 1 (M11 / GL9 safe module) faulty / blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003201 CNG_EXT_DEFLECTOR_DEF_INBOX_2 Reason: Switch cash-in cassette 1 (M12 / GL10 safe module) faulty / blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

Page 531: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 523

20003202 CNG_EXT_DEFLECTOR_DEF_INBOX_3 Reason: Switch cash-in cassette 1 (M13 / GL11 safe module) faulty / blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003203 CNG_EXT_DEFLECTOR_DEF_INBOX_4 Reason: Switch cash-in cassette 1 (M14 / GL12 safe module) faulty / blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003204 CNG_EXT_DEFLECTOR_DEF_INBOX_5 Reason: Switch cash-in cassette 1 (M15 / GL13 safe module) faulty / blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003205 CNG_EXT_DEFLECTOR_DEF_TRANSPNT Reason: Switch safe delivery /escrow / cash-out tray /MA3 /GL5 counter area) faulty/blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003206 CNG_EXT_DEFLECTOR_DEF_SINGLE_REJ Reason: Single reject (MA2) switch (after thickness measuring station at filling tray) faulty/blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

Page 532: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

524 June 2004

20003207 CNG_EXT_DEFLECTOR_DEFECT_ESCROW Reason: Switch escrow (MA6) faulty/blocked. Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003210 CNG_EXT_CRS_MS_DEFECT_CASHOUT Reason: Measuring station faulty (safe module) Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003211 CNG_EXT_CRS_LINE_X_ERROR_CONF Reason: Wrong tape sensor Line-X configuration. Measure: Check the currency data, configuration and firmware in the Line-XLA. Respectively load again and/or configure.

20003212 CNG_EXT_CRS_CONTAM_LINE_X_SENS Reason: Tape sensor Line-X soiled. Measure: Check/clean Line-XLA (Sensor window / press rolls).

20003213 CNG_EXT_CRS_LINE_X_SENS_DEFECT Reason: Tape sensor Line-X in the banknote identification module reports an error. Measure: Check the tape sensor in the banknote identification module or its configuration. If necessary replace the banknote identification module.

Page 533: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 525

20003214 CNG_EXT_CRS_TAPE_SENSOR_DEFECT Reason: Tape sensor in the banknote identification module reports an error. Measure: Check the tape sensor in the banknote identification module or its configuration. If necessary replace the banknote identification module.

20003215 CNG_EXT_CRS_MS_DEFECT_CASHIN Reason: Measuring station faulty (counter area) Measure: Replace the appropriate module or controller. Inform system administrator / service.

20003216 CNG_EXT_AUTHENTICATOR_READER_DEF Reason: Banknote identification module: reader background soiled or lines faulty. Measure: Justify or replace the banknote identification module. Inform system administrator / service.

20003217 CNG_EXT_AUTHENTICATOR_COMM_DEF Reason: Banknote identification module: communication reader faulty Measure: Replace the banknote identification module. Inform system administrator / service.

20003218 CNG_EXT_AUTHENTICATOR_NOTETIMING Reason: Banknote identification module: note impulse missing or out of tolerance. Measure: Replace the banknote identification module. Inform system administrator / service.

Page 534: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

526 June 2004

20003219 CNG_EXT_AUTHENTICATOR_RESPONSE Reason: The banknote identification module reports an acknowledgement error. Measure: Reconfigure or replace the banknote identification module. Inform system administrator / service.

20003220 CNG_EXT_CRS_LB_AMP_DEFECT Reason: Photosensor amplifier faulty or photosensor initialization not successfully or device not configured. Measure: Initialize or replace the photosensor amplifier. Inform system administrator / service.

20003230 CNG_EXT_CRS_DEFL_RETRACT_DEF Reason: Retract switch MA4 / GL8 (safe delivery / retract) faulty/blocked Measure: Replace the transport or controller. Inform system administrator / service.

20003231 CNG_EXT_CRS_DEFL_SELECTION_DEF Reason: Selection switch MA7 / GL14 at safe module (cassettes / rollers) faulty / blocked. Measure: Replace the transport or controller. Inform system administrator / service.

20003232 CNG_EXT_CRS_DEFL_REJECT_DEF Reason: Single reject switch MA8 /GL15 at safe module (safe delivery / cassettes) faulty/ blocked Measure: Replace the transport or controller. Inform system administrator / service.

Page 535: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 527

20003233 CNG_EXT_CRS_DEFL_RETRACT_DEF Reason: Switchover add-on compartment RR cassette MA20 / GL20 defective / blocked. Measure: Replace transport or controller. Inform system administrator / service.

20003234 CNG_EXT_CRS_DEFL_SELECTION_DEF Reason: Selection switch MA21 / GL21 in the cash area (cassettes / drums) is defective/blocked. Measure: Replace transport or controller. Inform system administrator / service.

20003235 CNG_EXT_CRS_DEFL_SELECT_REJ_DEF Reason: Selection switch MA22 / GL22 in the cash area (cassettes / drums) is defective/blocked. Measure: Replace transport or controller. Inform system administrator / service.

20003250 CNG_EXT_CRS_TRANS_MOTOR_M1_DEF Reason: Transport motor M1 (safe module) faulty / blocked. Measure: Replace the transport motor or controller. Inform system administrator / service.

20003251 CNG_EXT_CRS_TRANS_MOTOR_M4_DEF Reason: Transport motor M4 in the cash area is defective/blocked. Measure: Replace transport motor or controller. Inform system administrator / service.

20003255 CNG_EXT_CRS_TRANS_MOTOR_M2_DEF Reason: Transport motor M2 (counter area) faulty / blocked. Measure: Replace the transport motor or controller. Inform system administrator / service.

Page 536: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

528 June 2004

20003256 CNG_EXT_CRS_TRANS_MOTOR_M3_DEF Reason: Transport motor M3 (counter area) faulty / blocked. Measure: Replace the transport motor or controller. Inform system administrator / service.

20003285 CNG_EXT_SHUTTER_ERROR_OUT_TRAY Reason: Shutter error cash-out tray Measure: Eliminate the error and perform a "RESET". If necessary inform System administrator.

20003286 CNG_EXT_SHUTTER_ERROR_IN_TRAY Reason: Shutter error filling tray Measure: Eliminate the error and perform a "RESET". If necessary inform System administrator.

20003287 CNG_EXT_ROCKER_BLOCKED_OUT_TRAY Reason: Beater in cash-out tray blocked Measure: Eliminate the error and perform a "RESET". If necessary inform System administrator.

20003295 CNG_EXT_MANIPULATION_OUT_TRAY Reason: Photosensor cash-out tray covered Measure: Eliminate the error and perform a "RESET". If necessary inform System administrator.

20003296 CNG_EXT_MANIPULATION_IN_TRAY Reason: Photosensor filling tray covered Measure: Eliminate the error and perform a "RESET". If necessary inform System administrator.

Page 537: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 529

20003310 CNG_EXT_CASHOUT_CAS1_BUNDLE_REJ Reason: Too many bundle rejects (cash-out cassette 1) Measure: Check cash-out cassette 1, if necessary inform System administrator.

20003320 CNG_EXT_CASHOUT_CAS2_BUNDLE_REJ Reason: Too many bundle rejects (cash-out cassette 2) Measure: Check cash-out cassette 2, if necessary inform System administrator.

20003330 CNG_EXT_CASHOUT_CAS3_BUNDLE_REJ Reason: Too many bundle rejects (cash-out cassette 3) Measure: Check cash-out cassette 3, if necessary inform System administrator.

20003340 CNG_EXT_CASHOUT_CAS4_BUNDLE_REJ Reason: Too many bundle rejects (cash-out cassette 4) Measure: Check cash-out cassette 4, if necessary inform System administrator.

20003405 CNG_EXT_CASHIN_NO_SEPARATION Reason: Extraction from filling tray impossible Measure: Check the filling tray and perform a "RESET". If necessary inform system administrator.

20003406 CNG_EXT_CASHOUT_NO_SEPARATION Reason: Note extraction from cash-out tray impossible Measure: Check the cash-out tray and perform a "RESET". If necessary inform system administrator.

Page 538: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

530 June 2004

20003407 CNG_EXT_CRS_DETECT_METAL_CASHIN Reason: Metal detection in filling tray Measure: Check the filling tray content or replace it. If necessary inform system administrator.

20003408 CNG_EXT_CRS_DETECT_HIGH_CASHIN Reason: Banknote with excessive height detected in cash-in tray Measure: Check content of cash-in tray or replace it, inform system administrator if necessary.

20003410 CNG_EXT_CRS_CAS1_NO_SEPARATION Reason: Note extraction impossible (cash-out cassette 1) or incorrect note pressure while inserting the cassette. Measure: Check cash-out cassette 1, if necessary inform System administrator.

20003411 CNG_EXT_CRS_DRUM1_NO_SEPARATION Reason: Note extraction from Roller 1 impossible Measure: Check roller 1 and perform a "RESET". If necessary inform system administrator.

20003420 CNG_EXT_CRS_CAS2_NO_SEPARATION Reason: Note extraction impossible (cash-out cassette 2) or incorrect note pressure while inserting the cassette. Measure: Check cash-out cassette 2, if necessary inform System administrator.

20003421 CNG_EXT_CRS_DRUM2_NO_SEPARATION Reason: Note extraction from Roller 2 impossible Measure: Check roller 2 and perform a "RESET". If necessary inform system administrator.

Page 539: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 531

20003430 CNG_EXT_CRS_CAS3_NO_SEPARATION Reason: Note extraction impossible (cash-out cassette 3) or incorrect note pressure while inserting the cassette. Measure: Check cash-out cassette 3, if necessary inform System administrator.

20003431 CNG_EXT_CRS_DRUM3_NO_SEPARATION Reason: Note extraction from Roller 3 impossible Measure: Check roller 3 and perform a "RESET". If necessary inform system administrator.

20003440 CNG_EXT_CRS_CAS4_NO_SEPARATION Reason: Note extraction impossible (cash-out cassette 4) or incorrect note pressure while inserting the cassette. Measure: Check cash-out cassette 4, if necessary inform System administrator.

20003441 CNG_EXT_CRS_DRUM4_NO_SEPARATION Reason: Note extraction from Roller 4 impossible Measure: Check roller 4 and perform a "RESET". If necessary inform system administrator.

20003451 CNG_EXT_CRS_DRUM5_NO_SEPARATION Reason: Note extraction from Roller 5 impossible Measure: Check roller 5 and perform a "RESET". If necessary inform system administrator.

20003461 CNG_EXT_CRS_DRUM6_NO_SEPARATION Reason: Note extraction from Roller 6 impossible Measure: Check roller 6 and perform a "RESET". If necessary inform system administrator.

Page 540: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

532 June 2004

20003510 CNG_EXT_CRS_CAS1_OUT_WIDTH_TOL Reason: Too many bad notes (cash-out cassette 1) Measure: Check the content of cash-out cassette 1 and perform a "RESET". If necessary inform system administrator.

20003520 CNG_EXT_CRS_CAS2_OUT_WIDTH_TOL Reason: Too many bad notes (cash-out cassette 2) Measure: Check the content of cash-out cassette 2 and perform a "RESET". If necessary inform system administrator.

20003530 CNG_EXT_CRS_CAS3_OUT_WIDTH_TOL Reason: Too many bad notes (cash-out cassette 3) Measure: Check the content of cash-out cassette 3 and perform a "RESET". If necessary inform system administrator.

20003540 CNG_EXT_CRS_CAS4_OUT_WIDTH_TOL Reason: Too many bad notes (cash-out cassette 4) Measure: Check the content of cash-out cassette 4 and perform a "RESET". If necessary inform system administrator.

20003605 CNG_EXT_ESCROW_DEFECT Reason: ESCROW faulty (no impulse) Measure: Replace the ESCROW. Inform system administrator.

20003606 CNG_EXT_ESCROW_START_ERROR Reason: ESCROW: beginning of tape not found or not leave. Measure: Perform a "RESET".

Page 541: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 533

20003607 CNG_EXT_ESCROW_STEP_MOTOR Reason: Internal ESCROW error (step motor) Measure: Perform a "RESET".

20003608 CNG_EXT_ESCROW_TIMING Reason: Wrong values from ESCROW impulse panel Measure: Inform system administrator

20003610 CNG_EXT_CRS_CAS1_EEPROM_ERR Reason: Cash-out cassette 1 faulty Measure: Inform service.

20003611 CNG_EXT_CRS_DRUM1_DEFECT Reason: Roller 1 faulty Measure: Inform service.

20003620 CNG_EXT_CRS_CAS2_EEPROM_ERR Reason: Cassette 2 faulty Measure: Inform service.

20003621 CNG_EXT_CRS_DRUM2_DEFECT Reason: Roller 2 faulty Measure: Inform service.

Page 542: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

534 June 2004

20003630 CNG_EXT_CRS_CAS3_EEPROM_ERR Reason: Cassette 3 faulty Measure: Inform service.

20003631 CNG_EXT_CRS_DRUM3_DEFECT Reason: Roller 3 faulty Measure: Inform service.

20003640 CNG_EXT_CRS_CAS4_EEPROM_ERR Reason: Cassette 4 faulty Measure: Inform service.

20003641 CNG_EXT_CRS_DRUM4_DEFECT Reason: Roller 4 faulty Measure: Inform service.

20003651 CNG_EXT_CRS_DRUM5_DEFECT Reason: Roller 5 faulty Measure: Inform service.

20003661 CNG_EXT_CRS_DRUM6_DEFECT Reason: Roller 6 faulty Measure: Inform service.

Page 543: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 535

20003700 CNG_EXT_CRS_CONTAM_MS_SAFE Reason: Photosensor thickness measuring station (safe module) soiled. Measure: Inform system administrator.

20003705 CNG_EXT_CRS_CONTAM_MS_COUNT Reason: Photosensor thickness measuring station (counter area) soiled. Measure: Inform system administrator.

20003710 CNG_EXT_CRS_DEDUC_FLAG_LAM1 Reason: Dispenser sensor soiled (cash-out cassette 1) or pressure sensor faulty. Measure: Inform system administrator.

20003720 CNG_EXT_CRS_DEDUC_FLAG_LAM2 Reason: Dispenser sensor soiled (cash-out cassette 2) or pressure sensor faulty. Measure: Inform system administrator.

20003730 CNG_EXT_CRS_DEDUC_FLAG_LAM3 Reason: Dispenser sensor soiled (cash-out cassette 3) or pressure sensor faulty. Measure: Inform system administrator.

20003740 CNG_EXT_CRS_DEDUC_FLAG_LAM4 Reason: Dispenser sensor soiled (cash-out cassette 4) or pressure sensor faulty. Measure: Inform system administrator.

Page 544: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

536 June 2004

20003810 CNG_EXT_CRS_EMPTY_FLAG_KL1 Reason: Empty sensor soiled (cash-out cassette 1) Measure: Inform system administrator.

20003820 CNG_EXT_CRS_EMPTY_FLAG_KL2 Reason: Empty sensor soiled (cash-out cassette 2) Measure: Inform system administrator.

20003830 CNG_EXT_CRS_EMPTY_FLAG_KL3 Reason: Empty sensor soiled (cash-out cassette 3) Measure: Inform system administrator.

20003840 CNG_EXT_CRS_EMPTY_FLAG_KL4 Reason: Empty sensor soiled (cash-out cassette 4) Measure: Inform system administrator.

20003901 CNG_EXT_CRS_CONTAM_LB1 Reason: Photosensor LS1 (counter area) soiled Measure: Inform system administrator.

20003902 CNG_EXT_CRS_CONTAM_LB2 Reason: Photosensor LS2 (counter area) soiled Measure: Inform system administrator.

Page 545: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 537

20003903 CNG_EXT_CRS_CONTAM_LB3 Reason: Photosensor LS3 (counter area) soiled Measure: Inform system administrator.

20003904 CNG_EXT_CRS_CONTAM_LB4 Reason: Photosensor LS4 (counter area) soiled Measure: Inform system administrator.

20003905 CNG_EXT_CRS_CONTAM_LB5 Reason: Photosensor LS5 (counter area) soiled Measure: Inform system administrator.

20003906 CNG_EXT_CRS_CONTAM_LB6 Reason: Photosensor LS6 (counter area) soiled Measure: Inform system administrator.

20003907 CNG_EXT_CRS_CONTAM_LB7 Reason: Photosensor LS7 (counter area) soiled Measure: Inform system administrator.

20003908 CNG_EXT_CRS_CONTAM_LB8 Reason: Photosensor LS8 (counter area) soiled Measure: Inform system administrator.

Page 546: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

538 June 2004

20003909 CNG_EXT_CRS_CONTAM_LB9 Reason: Photosensor LS9 (counter area) soiled Measure: Inform system administrator.

20003910 CNG_EXT_CRS_CONTAM_LB10 Reason: Photosensor LS10 (safe module) soiled Measure: Inform system administrator.

20003911 CNG_EXT_CRS_CONTAM_LB11 Reason: Photosensor LS11 (safe module) soiled Measure: Inform system administrator.

20003912 CNG_EXT_CRS_CONTAM_LB12 Reason: Photosensor LS12 (safe module) soiled Measure: Inform system administrator.

20003913 CNG_EXT_CRS_CONTAM_LB13 Reason: Photosensor LS13 (safe module) soiled Measure: Inform system administrator.

20003914 CNG_EXT_CRS_CONTAM_LB14 Reason: Photosensor LS14 (safe module) soiled Measure: Inform system administrator.

Page 547: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 539

20003915 CNG_EXT_CRS_CONTAM_LB15 Reason: Photosensor LS15 (safe module) soiled Measure: Inform system administrator.

20003916 CNG_EXT_CRS_CONTAM_LB16 Reason: Photosensor LS16 (safe module) soiled Measure: Inform system administrator.

20003917 CNG_EXT_CRS_CONTAM_LB17 Reason: Photosensor LS17 (safe module) soiled Measure: Inform system administrator.

20003918 CNG_EXT_CRS_CONTAM_LB18 Reason: Photosensor LS18 (safe module) soiled Measure: Inform system administrator.

20003919 CNG_EXT_CRS_CONTAM_LB19 Reason: Photosensor LS19 (safe module) soiled Measure: Inform system administrator.

20003920 CNG_EXT_CRS_CONTAM_LB20 Reason: Photosensor LS20 (safe module) soiled Measure: Inform system administrator.

Page 548: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

540 June 2004

20003921 CNG_EXT_CRS_CONTAM_LB21 Reason: Photosensor LS21 (safe module) soiled Measure: Inform system administrator.

20003922 CNG_EXT_CRS_CONTAM_LB22 Reason: Photosensor LS22 (safe module) soiled Measure: Inform system administrator.

20003923 CNG_EXT_CRS_CONTAM_LB23 Reason: Photosensor LS23 (safe module) soiled Measure: Inform system administrator.

20003924 CNG_EXT_CRS_CONTAM_LB24 Reason: Photosensor LS24 (safe module) soiled Measure: Inform system administrator.

20003925 CNG_EXT_CRS_CONTAM_LB25 Reason: Photosensor LS25 (counter module) soiled. Measure: Inform system administrator.

20003926 CNG_EXT_CRS_CONTAM_LB26 Reason: Photosensor LS26 (counter module) soiled. Measure: Inform system administrator.

Page 549: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 541

20003931 CNG_EXT_CRS_CONTAM_LB_DRUM1 Reason: Phostosensor roller 1 (safe module) soiled Measure: Inform system administrator.

20003932 CNG_EXT_CRS_CONTAM_LB_DRUM2 Reason: Phostosensor roller 2 (safe module) soiled Measure: Inform system administrator.

20003933 CNG_EXT_CRS_CONTAM_LB_DRUM3 Reason: Phostosensor roller 3 (safe module) soiled Measure: Inform system administrator.

20003934 CNG_EXT_CRS_CONTAM_LB_DRUM4 Reason: Phostosensor roller 4 (safe module) soiled Measure: Inform system administrator.

20003935 CNG_EXT_CRS_CONTAM_LB_DRUM5 Reason: Phostosensor roller 5 (safe module) soiled Measure: Inform system administrator.

20003936 CNG_EXT_CRS_CONTAM_LB_DRUM6 Reason: Phostosensor roller 6 (safe module) soiled Measure: Inform system administrator.

Page 550: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

542 June 2004

20003941 CNG_EXT_CRS_DRUM1_WRONG_POS Reason: The filled roller 1 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

20003942 CNG_EXT_CRS_DRUM2_WRONG_POS Reason: The filled roller 2 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

20003943 CNG_EXT_CRS_DRUM3_WRONG_POS Reason: The filled roller 3 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

20003944 CNG_EXT_CRS_DRUM4_WRONG_POS Reason: The filled roller 4 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

20003945 CNG_EXT_CRS_DRUM5_WRONG_POS Reason: The filled roller 5 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

20003946 CNG_EXT_CRS_DRUM6_WRONG_POS Reason: The filled roller 6 is not placed at the original position or the 36Volt voltage is missing at the roller. Measure: Inform system administrator or service.

Page 551: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 543

20003951 CNG_EXT_CRS_ERR_LOAD_FW_COMP_1 Reason: Error in download of firmware for drum 1 subcomponent or 1st vertical stacker cassette. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003952 CNG_EXT_CRS_ERR_LOAD_FW_COMP_2 Reason: Error in download of the firmware for drum 2 subcomponent or 2nd vertical stacker cassette. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003953 CNG_EXT_CRS_ERR_LOAD_FW_COMP_3 Reason: Error in download of firmware for drum 3 subcomponent. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003954 CNG_EXT_CRS_ERR_LOAD_FW_COMP_4 Reason: Error in download of firmware for drum 4 subcomponent. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003955 CNG_EXT_CRS_ERR_LOAD_FW_COMP_5 Reason: Error in download of firmware for drum 5 subcomponent. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003961 CNG_EXT_CRS_ERR_LOAD_FW_HSK_1 Reason: Error in download of the firmware for HSK 1. Measure: Repeat firmware download, otherwise inform system administrator or service.

Page 552: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

544 June 2004

20003962 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_1 Reason: Error in download of firmware for 1st HSK 2. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003963 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_2 Reason: Error in download of firmware for 2nd HSK 2. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003964 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_3 Reason: Error in download of firmware for 3rd HSK 2. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003965 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_4 Reason: Error in download of firmware for 4th HSK 2. Measure: Repeat firmware download, otherwise inform system administrator or service.

20003971 CNG_EXT_CRS_COMM_ERROR_HSK_1 Reason: Communication error of HSK 1. Measure: epeat insertion of HSK 1 and repeat transaction; otherwise inform system administrator or service.

20003972 CNG_EXT_CRS_COMM_ERROR_HSK_2_1 Reason: Communication error of 1st HSK 2. Measure: Repeat insertion of 1st HSK 2 and repeat transaction, otherwise inform system administrator or service.

Page 553: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 545

20003973 CNG_EXT_CRS_COMM_ERROR_HSK_2_2 Reason: Communication error of 2nd HSK 2. Measure: Repeat insertion of 2nd HSK 2 and repeat transaction; otherwise inform system administrator or service.

20003974 CNG_EXT_CRS_COMM_ERROR_HSK_2_3 Reason: Communication error of 3rd HSK 2. Measure: Repeat insertion of 3rd HSK 2 and repeat transaction; otherwise inform system administrator or service.

20003975 CNG_EXT_CRS_COMM_ERROR_HSK_2_4 Reason: Communication error of 4th HSK 2. Measure: Repeat insertion of 4th HSK 2 and repeat transaction; otherwise inform system administrator or service.

20004001 CNG_EXT_SW_DEFEKT Reason: No response from the CDM (software) Measure: Start system again, if necessary inform System administrator.

20004010 CNG_EXT_CONTR_DEFEKT Reason: CDM electronics faulty Measure: Replace controller.

Page 554: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

546 June 2004

20004011 CNG_EXT_NO_FIRMWARE Reason: Software missing in the CDM Application: Load the firmware with the API function "CscCngInit". Measure: Put the application again into operation. If necessary inform System administrator.

20004012 CNG_EXT_SAFETY_CIRC_BREAK_OPEN Reason: CDM has not been inserted completely Measure: Bring the CDM into the cash-out position in the safe. If necessary inform System administrator.

20004013 CNG_EXT_DLOC_YES Reason: The maximal number of retracts has been reached Application: Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK". Measure: Remove the customer money from the retract box and transport path using operator function.

20004018 CNG_EXT_JAM_DISPENSE Reason: Note jam during dispensing Cash not accessible by customer Measure: Check the note path from the cassettes to the collecting tray. If necessary inform System administrator.

20004020 CNG_EXT_SINGLE_REJ_DEFECT Reason: Single reject switch faulty/blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 555: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 547

20004021 CNG_EXT_MS_DEFECT Reason: Measuring station faulty Measure: Inform service.

20004022 CNG_EXT_LBAMP_DEFECT Reason: Photosensor amplifier faulty or photosensor initialization not successful. Measure: Check the note paths using operator function. If necessary inform System administrator.

20004025 CNG_EXT_VMOTOR_DEFECT Reason: Dispensing drive faulty/blocked BBA UT: CDM has not been inserted completely Measure: Check the note paths using operator function. If necessary inform System administrator BBA UT: Bring the CDM into the cash-out position in the safe.

20004026 CNG_EXT_COL_TRAY_DEFECT Reason: CDM_NG: Switching dispensing/transport or vertical transport faulty/blocked CMD-V4: Stacker drive faulty /blocked Measure: Check the note paths using operator function. If necessary inform System administrator.

20004100 CNG_EXT_CAS_NOT_READY Reason: Cassette unknown , missing, reinserted Application: Dispensing command and reference value cannot be executed. Cash can be dispensed out of another cassette. Measure: Insert the cash-out cassette(s) and log on using operator function.

Page 556: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

548 June 2004

20004114 CNG_EXT_CONFIG_NO_REJECT Reason: Reject cassette missing Measure: Insert the reject cassette and log on using operator function.

20004119 CNG_EXT_JAM_REJECT_STACK_REJ Reason: Money jam in the output transport facility during reject Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004123 CNG_EXT_RESET_RW_DEFECT Reason: Rreject- / circle switch faulty/blocked Cash not accessible by customer Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20004124 CNG_EXT_RESET_RR_DEFECT Reason: Reject/retract drive faulty/blocked Cash not accessible by customer Measure: Check the reject cassette using operator function. If necessary inform System administrator.

20004128 CNG_EXT_TRANS_SHUT_ERR_OPEN Reason: Shutter cannot be opened/defect Cash not accessible by customer Measure: Check shutter, if necessary inform System administrator.

Page 557: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 549

20004129 CNG_EXT_OFFER_LB_L26_UE_COV Reason: Manipulation in Cash-out position Cash was removed from customer Measure: Check shutter, if necessary inform System administrator.

20004200 CNG_EXT_SHUTTER_BLOCKED Reason: Shutter have been blocked Application: The command cannot be executed. Measure: Examine the cash-out of the SAT and shutter for foreign matters.

20004214 CNG_EXT_CONFIG_REJECT_NOT_READY Reason: Reject cassette not logged on Measure: Insert the reject cassette and log on using operator function.

20004219 CNG_EXT_JAM_REJECT_OVER_STACKER Reason: Money jam in the output transport facility during reject Cash not accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004223 CNG_EXT_RETRACT_RW_DEFECT Reason: Reject-/Circle switch faulty/blocked Cash was accessible by customer during retract Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

Page 558: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

550 June 2004

20004224 CNG_EXT_RETRACT_RR_DEFECT Reason: Reject/retract drive faulty/blocked Cash was accessible by customer during retract Measure: Check the reject cassette using operator function. If necessary inform System administrator.

20004228 CNG_EXT_OFFER_SHUT_ERR_UNDEF Reason: Shutter undefined Cash was accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004229 CNG_EXT_WITHDRAWN_LB_L26_UE_COV Reason: Manipulation in withdrawal position Cash has been withdrawn by the customer Measure: Check shutter, if necessary inform System administrator.

20004300 CNG_EXT_SHUTTER_OPEN Reason: Shutter open Application: The command cannot be executed Measure: Check shutter

20004314 CNG_EXT_CONFIG_NO_CAS Reason: Cash-out cassette(s) missing Measure: Insert the cash-out cassette(s) and log on using operator function.

Page 559: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 551

20004319 CNG_EXT_JAM_TRANS_STACKER_OVER Reason: Money jam in the output transport facility during delivery Cash not accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004328 CNG_EXT_WITHDRAWN_SHUT_ERR_CLOS Reason: Shutter cannot be closed / undefined Cash has been withdrawn by the customer Measure: Check shutter, if necessary inform System administrator.

20004329 CNG_EXT_RETRACT_LB_L26_UE_COV Reason: Manipulation during retract Cash was accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004400 CNG_EXT_SHUTTER_UNDEFINED Reason: Shutter undefined Application: The command cannot be executed. Measure: Check shutter.

20004414 CNG_EXT_CONFIG_CAS_NOT_READY Reason: No cash-out cassette(s) logged on Measure: Log on the cash-out cassette(s) using operator function.

Page 560: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

552 June 2004

20004419 CNG_EXT_JAM_TRANS_OVER_SHUT Reason: Money jam in the output transport facility during delivery Cash was accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004428 CNG_EXT_RETRACT_SHUT_ERR_UNDEF Reason: Shutter undefined during retract Cash was accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004429 CNG_EXT_TRANS_LB_L26_UE_COVERED Reason: Manipulation during delivery Cash not accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004500 CNG_EXT_L26_UE_COVERED Reason: Manipulation at cash-out photosensor Application: The command cannot be executed. Measure: Inform System administrator.

20004519 CNG_EXT_JAM_RETR_SHUT_OVER Reason: Money jam in the output transport facility during retract Cash was accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

Page 561: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 553

20004529 CNG_EXT_OFFER_SHUT_BLOCKED Reason: Manipulation during delivery Cash was accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004600 CNG_EXT_LB_COVERED Reason: Note paths blocked Application: The command cannot be executed. Measure: Check all note paths. Inform System administrator.

20004619 CNG_EXT_JAM_RETR_HORIZ_STACKER Reason: Money jam in the output transport facility during retract Cash was accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004629 CNG_EXT_WITHDRAWN_SHUT_BLOCKED Reason: Manipulation in withdrawal position Cash has been withdrawn by the customer Measure: Check shutter, if necessary inform System administrator.

20004700 CNG_EXT_DEVICE_LOCK Reason: The maximal number of retracts has been reached Application: Command cannot be executed. Reset the lock flag by using the API function "CscCngStatusWrite - CNG_STATUS_UNLOCK" Measure: Remove the customer money from the retract box and transport path using operator function.

Page 562: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

554 June 2004

20004719 CNG_EXT_JAM_RETR_STACKER_REJ Reason: Money jam in the output transport facility during retract Cash was accessible by customer Measure: Eliminate money jam using operator function. If necessary inform System administrator.

20004729 CNG_EXT_RETR_SHUT_BLOCKED Reason: Manipulation during retract Cash was accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004800 CNG_EXT_SINGLE_REJ_ERROR Reason: Single reject switch faulty Application: The dispensing command and reference value cannot be executed. Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20004829 CNG_EXT_TRANS_SHUT_BLOCKED Reason: Manipulation during delivery Cash not accessible by customer Measure: Check shutter, if necessary inform System administrator.

20004900 CNG_EXT_SELF_TEST_AKTIVATE Reason: Self-test activated Application: Command cannot be executed, RESET. Measure: If necessary eliminate money jam using operator function. Bring the CDM into the cash-out position in the safe. If necessary inform System administrator.

Page 563: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 555

20004919 CNG_EXT_OFFER_LB_UE_COV Reason: Transport photosensor covered during withdrawal Cash was accessible by customer Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20004A00 CNG_EXT_FEED_JAM Reason: The jam was not eliminated effectively Application: Command cannot be executed. Measure: If necessary eliminate money jam using operator function. Bring the CDM into the cash-out position in the safe. If necessary inform System administrator.

20004A19 CNG_EXT_WITHDRAWN_LB_UE_COV Reason: Transport photosensor unexpectedly covered during withdrawal Cash has been withdrawn by the customer Measure: If necessary eliminate money jam using operator function. If necessary inform System administrator.

20004B00 CNG_EXT_CAS_MISSING Reason: Cash-out cassette missing or not inserted correctly Application: The command cannot be executed. Cash can be dispensed out of another cassette. Measure: Insert the cash-out cassette(s) and log on using operator function.

20004B19 CNG_EXT_RETR_LB_UE_COV Reason: Transport photosensor unexpectedly covered during retract Cash was accessible by customer Measure: if necessary eliminate money jam operator function. If necessary inform System administrator.

Page 564: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

556 June 2004

20004C19 CNG_EXT_MOTOR_DEFECT Reason: Motor defect Measure: inform service.

20004D00 CNG_EXT_CAS_EMPTY Reason: Cassette is empty Application: The command cannot be executed. Cash can be dispensed out of another cassette. Measure: Insert the filled cash-out cassette(s) and log on using operator function.

20004E00 CNG_EXT_CAS_DEFECT Reason: Cassette or dispensing sensor defect Application: The command cannot be executed. Cash can be dispensed out of another cassette. Measure: Insert the cash-out cassette(s) and log on using operator function.

20004F00 CNG_EXT_CAS_DISP_EMPTY Reason: A cassette becomes empty during dispensing procedure. Application: Requested amount cannot be dispensed. Cash can be dispensed out of another cassette. Measure: Insert the filled cash-out cassette(s) and log on using operator function.

20008031 CNG_EXT_CAS1_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 1) Measure: Check cassette 1, if necessary inform System administrator.

Page 565: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 557

20008032 CNG_EXT_CAS2_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 2) Measure: Check cassette 2, if necessary inform System administrator.

20008033 CNG_EXT_CAS3_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 3) Measure: Check cassette 3, if necessary inform System administrator.

20008034 CNG_EXT_CAS4_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 4) Measure: Check cassette 4, if necessary inform System administrator.

20008035 CNG_EXT_CAS5_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 5) Measure: Check cassette 5, if necessary inform System administrator.

20008036 CNG_EXT_CAS6_BUNDLE_REJECT Reason: Too many bundle rejects (cassette 6) Measure: Check cassette 6, if necessary inform System administrator.

20008041 CNG_EXT_CAS1_NO_SEPARATION Reason: Note extraction impossible (cassette 1) or incorrect note pressure while inserting the cassette. Measure: Check cassette 1, if necessary inform System administrator.

Page 566: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

558 June 2004

20008042 CNG_EXT_CAS2_NO_SEPARATION Reason: Note extraction impossible (cassette 2) or incorrect note pressure while inserting the cassette. Measure: Check cassette 2, if necessary inform System administrator.

20008043 CNG_EXT_CAS3_NO_SEPARATION Reason: Note extraction impossible (cassette 3) or incorrect note pressure while inserting the cassette. Measure: Check cassette 3, if necessary inform System administrator.

20008044 CNG_EXT_CAS4_NO_SEPARATION Reason: Note extraction impossible (cassette 4) or incorrect note pressure while inserting the cassette. Measure: Check cassette 4, if necessary inform System administrator.

20008045 CNG_EXT_CAS5_NO_SEPARATION Reason: Note extraction impossible (cassette 5) or incorrect note pressure while inserting the cassette. Measure: Check cassette 5, if necessary inform System administrator.

20008046 CNG_EXT_CAS6_NO_SEPARATION Reason: Note extraction impossible (cassette 6) or incorrect note pressure while inserting the cassette. Measure: Check cassette 6, if necessary inform System administrator.

20008061 CNG_EXT_CAS1_EEPROM_ERR Reason: Cassette 1 faulty Measure: Inform service.

Page 567: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 559

20008062 CNG_EXT_CAS2_EEPROM_ERR Reason: Cassette 2 faulty Measure: Inform service.

20008063 CNG_EXT_CAS3_EEPROM_ERR Reason: Cassette 3 faulty Measure: Inform service.

20008064 CNG_EXT_CAS4_EEPROM_ERR Reason: Cassette 4 faulty Measure: Inform service.

20008065 CNG_EXT_CAS5_EEPROM_ERR Reason: Cassette 5 faulty Measure: Inform service.

20008066 CNG_EXT_CAS6_EEPROM_ERR Reason: Cassette 6 faulty Measure: Inform service.

20008070 CNG_EXT_CONTAM_MS Reason: Photosensors measuring station soiled Measure: Inform system administrator.

Page 568: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

560 June 2004

20008071 CNG_EXT_DEDUC_FLAG_LAM1 Reason: Dispenser sensor soiled (cassette 1) or pressure sensor faulty. Measure: Inform system administrator.

20008072 CNG_EXT_DEDUC_FLAG_LAM2 Reason: Dispenser sensor soiled (cassette 2) or pressure sensor faulty. Measure: Inform system administrator.

20008073 CNG_EXT_DEDUC_FLAG_LAM3 Reason: Dispenser sensor soiled (cassette 3) or pressure sensor faulty. Measure: Inform system administrator.

20008074 CNG_EXT_DEDUC_FLAG_LAM4 Reason: Dispenser sensor soiled (cassette 4) or pressure sensor faulty. Measure: Inform system administrator.

20008075 CNG_EXT_DEDUC_FLAG_LAM5 Reason: Dispenser sensor soiled (cassette 5) or pressure sensor faulty. Measure: Inform system administrator.

20008076 CNG_EXT_DEDUC_FLAG_LAM6 Reason: Dispenser sensor soiled (cassette 6) or pressure sensor faulty. Measure: Inform system administrator.

Page 569: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 561

20008081 CNG_EXT_EMPTY_FLAG_KL1 Reason: Empty sensor soiled (cassette 1) Measure: Inform system administrator.

20008082 CNG_EXT_EMPTY_FLAG_KL2 Reason: Empty sensor soiled (cassette 2) Measure: Inform system administrator.

20008083 CNG_EXT_EMPTY_FLAG_KL3 Reason: Empty sensor soiled (cassette 3) Measure: Inform system administrator.

20008084 CNG_EXT_EMPTY_FLAG_KL4 Reason: Empty sensor soiled (cassette 4) Measure: Inform system administrator.

20008085 CNG_EXT_EMPTY_FLAG_KL5 Reason: Empty sensor soiled (cassette 5) Measure: Inform system administrator.

20008086 CNG_EXT_EMPTY_FLAG_KL6 Reason: Empty sensor soiled (cassette 6) Measure: Inform system administrator.

Page 570: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

562 June 2004

20008090 CNG_EXT_CONTAM_LB1 Reason: Photosensor L1 soiled Measure: Inform system administrator.

20008091 CNG_EXT_CONTAM_LB18 Reason: Photosensor L18 soiled Measure: Inform system administrator.

20008092 CNG_EXT_CONTAM_LB19 Reason: Photosensor L19 soiled Measure: Inform system administrator.

20008093 CNG_EXT_CONTAM_LB21 Reason: Photosensor L21 soiled Measure: Inform system administrator.

20008094 CNG_EXT_CONTAM_LB22 Reason: Photosensor L22 soiled Measure: Inform system administrator.

20008095 CNG_EXT_CONTAM_LB26 Reason: Photosensor L26 soiled Measure: Inform system administrator.

Page 571: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 563

20008096 CNG_EXT_CONTAM_LB33 Reason: Photosensor L33 soiled Measure: Inform system administrator.

20008097 CNG_EXT_CONTAM_LB35 Reason: Photosensor L35 soiled Measure: Inform system administrator.

20008098 CNG_EXT_CONTAM_LB27 Reason: Photosensor L27 soiled Measure: Inform system administrator.

20008099 CNG_EXT_CONTAM_LB28 Reason: Photosensor L28 soiled Measure: Inform system administrator.

2000809A CNG_EXT_CONTAM_LB29 Reason: Photosensor L29 soiled Measure: Inform system administrator.

2000809B CNG_EXT_CONTAM_LB36 Reason: Photosensor L36 soiled Measure: Inform system administrator.

Page 572: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

564 June 2004

2000809C CNG_EXT_CONTAM_LB37 Reason: Photosensor L37 soiled Measure: Inform system administrator.

20008151 CNG_EXT_CAS1_MULTIPLE_NOTES Reason: Too many double notes (cassette 1) Measure: Inform system administrator.

20008152 CNG_EXT_CAS2_MULTIPLE_NOTES Reason: Too many double notes (cassette 2) Measure: Inform system administrator.

20008153 CNG_EXT_CAS3_MULTIPLE_NOTES Reason: Too many double notes (cassette 3) Measure: Inform system administrator.

20008154 CNG_EXT_CAS4_MULTIPLE_NOTES Reason: Too many double notes (cassette 4) Measure: Inform system administrator.

20008155 CNG_EXT_CAS5_MULTIPLE_NOTES Reason: Too many double notes (cassette 5) Measure: Inform system administrator.

Page 573: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 565

20008156 CNG_EXT_CAS6_MULTIPLE_NOTES Reason: Too many double notes (cassette 6) Measure: Inform System administrator.

20008251 CNG_EXT_CAS1_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 1) Measure: Inform system administrator.

20008252 CNG_EXT_CAS2_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 2) Measure: Inform system administrator.

20008253 CNG_EXT_CAS3_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 3) Measure: Inform system administrator.

20008254 CNG_EXT_CAS4_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 4) Measure: Inform system administrator.

20008255 CNG_EXT_CAS5_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 5) Measure: Inform system administrator.

Page 574: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

566 June 2004

20008256 CNG_EXT_CAS6_OUT_WIDTH_TOL Reason: Too many bad notes (cassette 6) Measure: Inform system administrator.

20008300 CNG_EXT_COLL_TRAY_NOT_EMPTY_DIV Reason: Banknotes left in the stacker after output to the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008312 CNG_EXT_SAFE_CIRC_BRK_OPEN_DIV Reason: CDM has not been inserted completely. Cash or the first partial dispensing operation is in the diverter. Measure: Bring the CDM into the cash-out position in the safe. If necessary inform System administrator.

20008313 CNG_EXT_DLOC_YES_DIV Reason: There is cash left in the diverter after reset/booting. Application: Application specific behaviour. Measure: Remove the cash from the diverter using operator function.

20008314 CNG_EXT_CONFIG_DIVERTER Reason: Dispensing not possible. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 575: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 567

20008315 CNG_EXT_RIGHT_OCCUPIED_DIVERTER Reason: Command could not be executed as the right-hand output tray is still occupied. Application: Application specific behaviour. Measure: Remove the cash from the output tray using operator function.

20008316 CNG_EXT_LEFT_OCCUPIED_DIVERTER Reason: Command could not be executed as the left-hand output tray is still occupied. Application: Application specific behaviour. Measure: Remove the cash from the output tray using operator function.

20008318 CNG_EXT_JAM_DISPENSE_DIV Reason: Note jam during the second partial dispensing operation. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008319 CNG_EXT_JAM_TRANS_DIVERTER Reason: Note jam in the output transport. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008320 CNG_EXT_SINGLE_REJ_DEFECT_DIV Reason: Single reject switch faulty/blocked. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 576: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

568 June 2004

20008321 CNG_EXT_MS_DEFECT_DIV Reason: Measuring station faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008322 CNG_EXT_LBAMP_DEFECT_DIV Reason: Photosensor amplifier faulty or photosensor initialization not successful. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008323 CNG_EXT_RESET_RW_DEFECT_DIV Reason: Bundle reject switch faulty / blocked. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008324 CNG_EXT_RESET_RR_DEFECT_DIV Reason: Reject/retract drive faulty/blocked. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008325 CNG_EXT_VMOTOR_DEFECT_DIV Reason: Dispensing drive faulty/blocked. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

Page 577: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 569

20008326 CNG_EXT_COL_TRAY_DEFECT_DIV Reason: Switching dispensing/transport faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008328 CNG_EXT_TRANS_ERR_DIVERTER Reason: Diverter does not reach the specified end position. Possibly note jam in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008329 CNG_EXT_JAM_COLL_TRAY_DIV Reason: Banknotes jammed in the stacker, under the output photosensor. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008331 CNG_EXT_CAS1_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 1). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 1, if necessary inform System administrator.

20008332 CNG_EXT_CAS2_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 2). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 2, if necessary inform System administrator.

20008333 CNG_EXT_CAS3_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 3). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 3, if necessary inform System administrator.

Page 578: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

570 June 2004

20008334 CNG_EXT_CAS4_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 4). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 4, if necessary inform System administrator.

20008335 CNG_EXT_CAS5_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 5). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 5, if necessary inform System administrator.

20008336 CNG_EXT_CAS6_BUNDLE_REJECT_DIV Reason: Too many bundle rejects (cassette 6). Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 6, if necessary inform System administrator.

20008341 CNG_EXT_CAS1_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 1) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 1, if necessary inform System administrator.

20008342 CNG_EXT_CAS2_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 2) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 2, if necessary inform System administrator.

Page 579: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 571

20008343 CNG_EXT_CAS3_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 3) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 3, if necessary inform System administrator.

20008344 CNG_EXT_CAS4_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 4) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 4, if necessary inform System administrator.

20008345 CNG_EXT_CAS5_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 5) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 5, if necessary inform System administrator.

20008346 CNG_EXT_CAS6_NO_SEPARATION_DIV Reason: Note extraction impossible (cassette 6) or incorrect note pressure while inserting the cassette. Cash of the first partial dispensing operation is in the diverter. Measure: Check cassette 6, if necessary inform System administrator.

20008351 CNG_EXT_CAS1_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 1). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 580: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

572 June 2004

20008352 CNG_EXT_CAS2_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 2). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008353 CNG_EXT_CAS3_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 3). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008354 CNG_EXT_CAS4_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 4). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008355 CNG_EXT_CAS5_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 5). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008356 CNG_EXT_CAS6_MULTIPLE_NOTES_DIV Reason: Too many double notes (cassette 6). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 581: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 573

20008361 CNG_EXT_CAS1_EEPROM_ERR_DIV Reason: Cassette 1 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008362 CNG_EXT_CAS2_EEPROM_ERR_DIV Reason: Cassette 2 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008363 CNG_EXT_CAS3_EEPROM_ERR_DIV Reason: Cassette 3 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008364 CNG_EXT_CAS4_EEPROM_ERR_DIV Reason: Cassette 4 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008365 CNG_EXT_CAS5_EEPROM_ERR_DIV Reason: Cassette 5 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

20008366 CNG_EXT_CAS6_EEPROM_ERR_DIV Reason: Cassette 6 faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform Service.

Page 582: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

574 June 2004

20008370 CNG_EXT_CONTAM_MS_DIV Reason: Photosensors measuring station soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008371 CNG_EXT_DEDUC_FLAG_LAM1_DIV Reason: Dispenser sensor soiled (cassette 1) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008372 CNG_EXT_DEDUC_FLAG_LAM2_DIV Reason: Dispenser sensor soiled (cassette 2) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008373 CNG_EXT_DEDUC_FLAG_LAM3_DIV Reason: Dispenser sensor soiled (cassette 3) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008374 CNG_EXT_DEDUC_FLAG_LAM4_DIV Reason: Dispenser sensor soiled (cassette 4) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 583: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 575

20008375 CNG_EXT_DEDUC_FLAG_LAM5_DIV Reason: Dispenser sensor soiled (cassette 5) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008376 CNG_EXT_DEDUC_FLAG_LAM6_DIV Reason: Dispenser sensor soiled (cassette 6) or pressure sensor faulty. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008381 CNG_EXT_EMPTY_FLAG_KL1_DIV Reason: Empty sensor soiled (cassette 1). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008382 CNG_EXT_EMPTY_FLAG_KL2_DIV Reason: Empty sensor soiled (cassette 2). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008383 CNG_EXT_EMPTY_FLAG_KL3_DIV Reason: Empty sensor soiled (cassette 3). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 584: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

576 June 2004

20008384 CNG_EXT_EMPTY_FLAG_KL4_DIV Reason: Empty sensor soiled (cassette 4). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008385 CNG_EXT_EMPTY_FLAG_KL5_DIV Reason: Empty sensor soiled (cassette 5). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008386 CNG_EXT_EMPTY_FLAG_KL6_DIV Reason: Empty sensor soiled (cassette 6). Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008390 CNG_EXT_CONTAM_LB1_DIV Reason: Photosensor L1 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008391 CNG_EXT_CONTAM_LB18_DIV Reason: Photosensor L18 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 585: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 577

20008392 CNG_EXT_CONTAM_LB19_DIV Reason: Photosensor L19 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008393 CNG_EXT_CONTAM_LB21_DIV Reason: Photosensor L21 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008394 CNG_EXT_CONTAM_LB22_DIV Reason: Photosensor L22 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008395 CNG_EXT_CONTAM_LB26_DIV Reason: Photosensor L26 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008396 CNG_EXT_CONTAM_LB33_DIV Reason: Photosensor L33 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 586: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

578 June 2004

20008397 CNG_EXT_CONTAM_LB35_DIV Reason: Photosensor L35 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008398 CNG_EXT_CONTAM_LB27_DIV Reason: Photosensor L27 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008399 CNG_EXT_CONTAM_LB28_DIV Reason: Photosensor L28 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

2000839A CNG_EXT_CONTAM_LB29_DIV Reason: Photosensor L29 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

2000839B CNG_EXT_CONTAM_LB36_DIV Reason: Photosensor L36 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

Page 587: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

June 2004 579

2000839C CNG_EXT_CONTAM_LB37_DIV Reason: Photosensor L37 soiled. Cash of the first partial dispensing operation is in the diverter. Measure: Inform system administrator.

20008400 CNG_EXT_OUTPUT_NOT_EMPTY_DIV Reason: Banknotes left in the stacker after output to the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

20008419 CNG_EXT_JAM_TRANS_DIV_OCCUP Reason: Note jam in the output transport. Cash of the first partial dispensing operation is in the diverter. Measure: Check the note paths using operator function. If necessary inform System administrator.

2000A000 CNG_EXT_TRANS_LB_UE_COV Reason: Wrong command

2000A100 CNG_EXT_SYNTAX_ERROR Reason: Wrong command Application: Change application program Measure: Inform system administrator.

Page 588: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CNG: extended error codes

580 June 2004

2000A200 CNG_EXT_INVALID_PROG Reason: Programming error Application: Change application program Measure: Inform system administrator.

2000FFFF CNG_EXT_NO_EXTENDED_ERROR Reason: AZN-NG: The extended error code has not yet been generated, as a new error condition was defined in SCOD. CMD-V4: SCOD 08: Missing or faulty "Collector" EE-Prom SCOD 17: Jam or defect in gripper feed Application: Check the application if it was really necessary to inquire the extended error code.

Page 589: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 581

Firmware loader (LDR) StClass:

STCLASS_OK No error STCLASS_ERROR_LDR Error of the CSCWLDR.DLL

StCode:

20008000 LDR_FRM_ERROR Reason: The firmware indicates an unexpected error code. The buffer pOutData must be evaluated. Measure: Inform Customer Service.

20008001 LDR_INVALID_FRM_DATA Reason: Invalid data in response from peripheral controller. Measure: Check firmware file.

20008002 LDR_INVALID_FRM_FILE_MOD Reason: Invalid MODSEG ID in firmware file on the system. Measure: Check firmware file.

20008003 LDR_FRM_FILE_NOT_FOUND Reason: The firmware file was not found in the directory <CSCROOT>\FRM. Measure: Check configuration.

Page 590: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Firmware loader (LDR)

582 June 2004

20008004 LDR_FRM_FILE_OPEN_FAILED Reason: Error when open a firmware file. Measure: Check configuration.

Page 591: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 583

Paragraph 36 (P36) StClass:

STCLASS_OK No error STCLASS_ERROR_P36 Error of the CSCWP36.DLL

StCode:

20008000 P36_THREAD_START_ERROR Reason: The thread which receives the signature data could not started. Measure: Software error, inform service.

20008001 P36_THREAD_STOP_ERROR Reason: The thread which receives the signature data could not stopped. Measure: Software error, inform service.

20008002 P36_INVALID_P36SIGPARA Reason: The pointer "pP36SigPara" is illegal. Application: Transfer a legal pointer to the device handler in the application program.

2000F000 P36_ERR_CHKSUM2 Reason: The received signature data (BIM hardware -> PC) has a checksum error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 592: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Paragraph 36 (P36)

584 June 2004

2000F001 P36_INVALID_SIGDATA Reason: The received signature data is invalid (no start id, no stop id, no signature data between start and stop id). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FFFE P36_ERR_OVERFLOW Reason: The received signature data has a overflow error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FFFF P36_ERR_CHKSUM1 Reason: The received signature data (internal BIM -> hardware) has a checksum error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

StWarn:

2000F000 P36_WARN_CHKSUM2 Reason: The received signature data (BIM hardware -> PC) has a checksum error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 593: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Paragraph 36 (P36)

June 2004 585

2000FFFE P36_WARN_OVERFLOW Reason: The received signature data has a overflow error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FFFF P36_WARN_CHKSUM1 Reason: The received signature data (internal BIM -> hardware) has a checksum error. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 594: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

586 June 2004

Page 595: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 587

Coin-Out Module (COUT) StClass:

STCLASS_OK No error STCLASS_ERROR_COUT Error of the CSCWCOUT.DLL

StCode:

20008001 COUT_NO_COINS Reason: There are no coins inside the hopper. Application: Dispense from other hopper if possible. Measure: Refill with coins. Check hardware.

20008002 COUT_OUT_OF_ORDER Reason: The hopper does not work properly. Application: Stop further cash-out operations from hopper.

20008003 COUT_POWER_ERR_RECOVER Reason: Power supply failure with recovery. There has been a power failure while the machine was executing COUT_PAY_OUT and the state of the machine has been saved. Application: The required response depends on the application.

Page 596: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-Out Module (COUT)

588 June 2004

20008004 COUT_POWER_ERR Reason: Power supply failure without recovery. There has been a power failure while the machine was executing COUT_PAY_OUT and the state of the machine has not been saved. Application: The required response depends on the application.

20008005 COUT_RESET_RECOVER Reason: Reset with recovery. A reset occurred while the machine was executing COUT_PAY_OUT or COUT_PAY_EMPTY and the state of the machine has been saved. Application: The required response depends on the application.

20008006 COUT_RESET Reason: Reset without recovery. A reset occurred while the machine was executing COUT_PAY_OUT or COUT_PAY_EMPTY and the state of the machine has not been saved. Application: The required response depends on the application.

20008007 COUT_HOPPER_NOT_INSTALLED Reason: Hopper not installed. The hopper was not connected correctly when the system started or when the last manual test was done. Application: Check application program and dispense change from other hopper, if necessary. Measure: Check device configuration and correct it if necessary.

20008008 COUT_HOPPER_BLOCKED Reason: The motor of the hopper is blocked. Measure: Check the hopper. Remove coin jam if necessary.

Page 597: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-Out Module (COUT)

June 2004 589

20008009 COUT_SENSOR_ERROR Reason: Photosensor failure. The photosensor does not work properly or something has been placed in its beam during standby. Measure: Check photosensor or hardware.

2000800A COUT_HOPPER_NOT_CONNECTED Reason: The hopper is not connected, the wire is broken or the motor does not work. Application: Stop further cash-out operations from hopper. Dispense from other hopper if possible. Measure: Check the hardware.

2000801F COUT_INVALID_PARA Reason: Invalid parameters. The parameters of a command are out of range. Application: Check application program.

200080FF COUT_HOPPER_NOT_CONFIGURED Reason: The hopper is not configured via registry. Application: Stop further cash-out operations from hopper. Dispense from other hopper if possible. Measure: Check the registry.

20008100 COUT_PROTOCOL_TX_TIMEOUT Reason: The total protocol monitoring time during transmission has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 598: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-Out Module (COUT)

590 June 2004

20008101 COUT_PROTOCOL_RX_TIMEOUT Reason: The total protocol monitoring time during receive has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008102 COUT_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008103 COUT_MAX_TX_RETRIES Reason: The maximum number of repeat transmissions has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008104 COUT_MAX_RX_RETRIES Reason: The maximum number of receive repeats has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008105 COUT_TOO_MANY_COINS Reason: The number of coins per hopper to be paid out is invalid. Measure: Check the parameter MAXCOINSPERHOPPER in Registry.

Page 599: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-Out Module (COUT)

June 2004 591

20008106 COUT_LOW_LEVEL_SET Reason: The low-level switch is set before a pay-out command. Application: Repeat the command with the specification COUT_PAY_EMPTY.

20008107 COUT_INVALID_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in Registry. Measure: Check the parameters LED, LED_FLASH and LED_FREQ in Registry.

StWarn:

20009000 COUT_WARN_LED Reason: The device handler was configured to switch LEDs when pay out coins. An error occurred when accessing the SEL DH to switch the LEDs. Measure: Check the configuration of COUT and SEL device handler.

Page 600: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

592 June 2004

Page 601: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 593

Coin-In Module (CIN) StClass:

STCLASS_OK No error STCLASS_ERROR_CIN Error of the CSCWCIN.DLL

StCode:

20008100 CIN_PROTOCOL_TX_TIMEOUT Reason: The total protocol monitoring time during transmission has been exceeded. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008101 CIN_PROTOCOL_RX_TIMEOUT Reason: The total monitoring time during receive has been exceeded. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008102 CIN_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 602: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-In Module (CIN)

594 June 2004

20008103 CIN_MAX_TX_RETRIES Reason: The maximum number of repeat transmission has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008104 CIN_MAX_RX_RETRIES Reason: The maximum number of receive retries has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

28008001 CIN_DISK_JAM Reason: The coin disk is jammed. Measure: Check the coin disk, if necessary inform service.

28008002 CIN_COUNT_SECT_JAM Reason: There is a jam at the counter section detected. Measure: Check the counter section, if necessary inform service.

28008003 CIN_NO_MAIN_STORAGE Reason: The main storage is missing. Measure: Insert the main storage.

Page 603: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-In Module (CIN)

June 2004 595

28008004 CIN_LOW_VOLTAGE Reason: Voltage is too low. Measure: Call Customer Service.

28008005 CIN_REAL_TIME_CLOCK Reason: There is an error at the real time clock detected or the accumulator voltage is too low. Measure: Call Customer Service.

28008006 CIN_NO_VOLTAGE Reason: 8 volt and/or 24 volt has been interrupted or not present. Measure: Call Customer Service.

28008008 CIN_COIN_RECOGNITION Reason: General error while the device coin recognition. Measure: Call Customer Service.

2800800A CIN_START_CALIBRATE Reason: Error while the coin transaction is executed (calibrate error). Measure: Call Customer Service.

2800800B CIN_TEACH_CALIBRATE Reason: Error while the device is teaching (calibrate error). Measure: Call Customer Service.

Page 604: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Coin-In Module (CIN)

596 June 2004

2800800C CIN_FLAP_INTERMEDIATE_STORAGE Reason: The flap at the intermediate storage is jammed. Measure: Check the flap at the intermediate storage, if necessary inform service.

2800800D CIN_FLAP_MAIN_STORAGE Reason: The flap at the main storage is jammed. Measure: Check the flap at the main storage, if necessary inform service.

2800800E CIN_POSITION_FUNNEL Reason: The coin funnel is not in the right position. Measure: Call Customer Service.

2800800F CIN_INTERNAL_MEMORY_ERROR Reason: Internal memory error. Measure: Call Customer Service.

28008015 CIN_NO_EJECT_BOX Reason: The eject box was taken during the eject process. Measure: Check the eject box, if necessary inform service.

Page 605: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 597

Bundle Cash Deposit Module (BCD) StClass:

STCLASS_OK No error STCLASS_ERROR_BCD Error of the CSCWBCD.DLL

StCode:

20008000 BCD_INVALID_RESPONSE Reason: The BCD does not respond in the expected way to a command sent by the device handler (no ACK response, or incorrect data length). Application: Make sure the BCD is in the correct status ("operation step") for the requested function. Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware, or the BCD firmware version.

20008001 BCD_INVALID_COMMAND Reason: The BCD does not allow the requested function or specification during the current operation step. Application: Make sure the BCD is in the correct status ("operation step") for the requested function. Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware, or the BCD firmware version.

Page 606: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

598 June 2004

20008003 BCD_INVALID_BKNOTES_FILE Reason: The banknote denomination file bknotes.bcd cannot be opened or closed. Application: Make sure that no other application or thread opens this file exclusively, or wait and retry until the file is accessible again. Make sure there is enough free RAM to load the file. Measure: Check the existence and access permissions of the denomination file <CSCROOT>\FRM\bknotes.bcd.

20008004 BCD_INVALID_BKN_FILE_FORMAT Reason: Syntax error in the banknote denomination file bknotes.bcd. Measure: Check the banknote denomination file <CSCROOT>\FRM\bknotes.bcd. Make sure that the <country>.<denom> codes are written correctly. Make sure that all sections use only denominations that are defined in the [AcceptableBanknotes] section.

20008005 BCD_BKNFILE_SECTION_NOT_FOUND Reason: The requested denomination section was not found in the banknote denomination file bknotes.bcd. Application: Check the application software and the banknote denomination file <CSCROOT>\FRM\bknotes.bcd.

20008006 BCD_BKNFILE_DENOMIN_NOT_FOUND Reason: 1. A country/denomination code in the selected section of the denomination file bknotes.bcd was not found in the [AcceptableBanknotes] section. 2. A country/denomination code received from the BCD was not found in the denomination file bknotes.bcd (when looking up the symbolic name for that code). Measure: Check the denomination file <CSCROOT>\FRM\bknotes.bcd. Make sure that the <country>.<denom> codes are written correctly. Make sure that all sections use only denominations that are defined in the [AcceptableBanknotes] section. Make sure that the [AcceptableBanknotes] section contains exactly the denominations that are supported by the BCD firmware. Check the BCD hardware and firmware version.

Page 607: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

June 2004 599

20008007 BCD_SHUTTER_ERROR Reason: Error while accessing the BCD shutter (via the special electronics). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware, especially the SEL, the shutter hardware, and cables. Check the SEL configuration, esp. door1, door2, and distance sensor.

20008008 BCD_BAD_UVLAMP Reason: The banknote recognition unit has determined that the brightness of the UV lamp has fallen below 40% of the original value. Application: Cancel all open transactions and report a fatal error. After a replacement of the lamp, see section "Measure" below. Measure: Call a service technican to replace the defective part or unit. After replacement and restart, the lamp status flag is not reset the lamp has warmed up sufficiently (up to 30 minutes) and a valid banknote recognition has been made. Install the latest BCD device handler DLL (this error can occur only in older versions).

20008009 BCD_PROCESS_ERROR0 Reason: Error with the internal process synchronization: various mutex or event errors. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software.

2000800A BCD_PROCESS_ERROR1 Reason: Error at the start of the protocol process: CreateProcess returned an error. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software, especially <CSCROOT>\bin\bcdprotp.exe.

Page 608: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

600 June 2004

2000800B BCD_PROCESS_ERROR2 Reason: Error at the start of the protocol process: process was aborted. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software, especially <CSCROOT>\bin\bcdprotp.exe.

2000800C BCD_PROCESS_ERROR3 Reason: Error at the start of the protocol process: process does not respond. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software, especially <CSCROOT>\bin\bcdprotp.exe.

2000800D BCD_PROCESS_ERROR4 Reason: Error at the start of the protocol process: process did not start correctly. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software, especially <CSCROOT>\bin\bcdprotp.exe.

2000800E BCD_PROCESS_ERROR5 Reason: Error at the start of the protocol process: program version incompatible with the device handler. Application: Terminate. Measure: Restart the system. Check the installation of the CSC Software, especially CSCWBCD.DLL and BCDPROTP.EXE.

Page 609: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

June 2004 601

2000800F BCD_PROCESS_ERROR6 Reason: Error with the internal process synchronization: timeout during data transfer. Application: Terminate and start again. Measure: Restart the system. Check the installation of the CSC Software.

20008010 BCD_PROCESS_ERROR7 Reason: Error when trying to terminate the protocol process: process does not respond. Measure: Restart the system. Check the installation of the CSC Software.

20008020 BCD_INVALID_HANDLE2 Reason: The second serial line of the BCD (CSCBCD2) was not opened correctly. Application: Close and open the device again. Measure: Restart the system. Check the configuration key CSCBCD2.

20008021 BCD_INVALID_RESP2_XSUM Reason: Checksum error when receiving data on the second serial line of the BCD (CSCBCD2). Application: Repeat the function. Measure: Check the cable and connectors. Restart the system.

Page 610: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

602 June 2004

20008022 BCD_INVALID_RESP2_RES1 Reason: Error when receiving data on the second serial line of the BCD (CSCBCD2); the byte RES1 is invalid. Application: Repeat the function. Measure: Check the cable and connectors. Restart the system.

20008023 BCD_INVALID_RESP2_RES2 Reason: Error when receiving data on the second serial line of the BCD (CSCBCD2); the byte RES2 is invalid. Application: Repeat the function. Measure: Check the cable and connectors. Restart the system.

20008024 BCD_INVALID_RESP2_RES3 Reason: Error when receiving data on the second serial line of the BCD (CSCBCD2); the byte RES3 is invalid. Application: Repeat the function. Measure: Check the cable and connectors. Restart the system.

20008025 BCD_INVALID_RESP2_RES4 Reason: Error when receiving data on the second serial line of the BCD (CSCBCD2); the byte RES4 is invalid. Application: Repeat the function. Measure: Check the cable and connectors. Restart the system.

Page 611: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

June 2004 603

2000FE89 BCD_INVALID_PTXDATA Reason: The pointer "pTxData" is illegal. Application: Transfer a legal pointer to the Multiplexer in the application program.

2000FE92 BCD_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid (only ACK, NAK and DLE are valid). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE93 BCD_MAX_TX_RETRIES Reason: The maximum number of repeat transmissions has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE95 BCD_PROTOCOL_TX_TIMEOUT Reason: The total protocol monitoring time during transmission has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

2000FE96 BCD_PROTOCOL_RX_TIMEOUT Reason: The total protocol monitoring time during receive has been exceeded. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 612: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Bundle Cash Deposit Module (BCD)

604 June 2004

StWarn:

2000E004 BCD_WARN_LED Reason: An error occurred when accessing the SEL DH to switch an LED. Measure: Check the configuration of the BCD and the SEL device handlers. Check the hardware.

Page 613: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 605

Deposit Module (DPS) StClass:

STCLASS_OK No error STCLASS_ERROR_DPS Error of the CSCWDPS.DLL

StCode:

20008102 DPS_INVALID_DATA_ACCESS Reason: Cannot access full length of data area in a structure. Application: Check application program

20008104 DPS_INVALID_CANCEL Reason: Active function cannot be cancelled. Possibly a programming error. Application: Check application program.

20008105 DPS_FRM_FILE_OPEN_FAILED Reason: Cannot open the firmware file. Measure: Check the firmware file.

20008106 DPS_FRM_FILE_ACCESS_ERROR Reason: Cannot read the firmware file to be loaded. Measure: Check the firmware file.

Page 614: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

606 June 2004

20008107 DPS_INVALID_FRM_FILE_DATA Reason: Detect invalid firmware file data. Measure: Check the firmware file.

20008108 DPS_INVALID_FILE_CHKSUM Reason: Detect an invalid checksum of the firmware file data. Measure: Check the firmware file.

20008200 DPS_PROTOCOL_WRITE_TIMEOUT Reason: A V24 WRITE command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008201 DPS_PROTOCOL_READ_TIMEOUT Reason: A V24 READ command could not be executed in the specified monitoring time. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008202 DPS_MAX_TX_RETRIES Reason: The maximum number of repeat transmissions has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

Page 615: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

June 2004 607

20008203 DPS_MAX_RX_RETRIES Reason: The maximum number of receive repeats has been reached. Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008204 DPS_MAX_CDM_RETRIES Reason: Repetition counter expired. Application: Repeat job. Check appropriations in Registry/CSC.INI. If necessary raise counter. Measure: Check channel number / line. If recurs, notify Service Check hardware

20008205 DPS_INVALID_ACK_TYPE Reason: The received acknowledge type is invalid (only ACK and NAK are valid). Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check the hardware.

20008206 DPS_PROTOCOL_ENQ_TIMEOUT Reason: Repetition counter expired. Application: Repeat job Measure: Check channel number / line. If recurs, notify Service Check hardware

Page 616: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

608 June 2004

20008207 DPS_INVALID_FRM_DATA Reason: - expected block length does not match transmitted block length - invalid block label - invalid command specification Application: Repeat the command and if necessary initialize the device again beforehand. Measure: Check hardware.

20008208 DPS_ERROR_SEM_TIMEOUT Reason: An error (internal error) occurred during or after abortion of the CscDpsEntry job. Measure: Check configuration. Report the error log of this entry to Service.

20008209 DPS_PROTOCOL_CAN_TIMEOUT Reason: The CscDpsEntry job was cancelled by the user. This cancel was not confirmed by the unit. Measure: Check hardware. Re-initialize device if required. Report error log of this entry to Service.

20008300 DPS_INVALID_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in Registry/CSC.INI with [CSCDPS]. Measure: Check the parameters LED, LED_FLASH and LED_FREQ in Registry/CSC.INI.

28008000 DPS_FRM_UNDEF_ERROR Reason: Undefined error code Application: Repeat job Measure: Initialize device. If error recurs, notify Service Check hardware

Page 617: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

June 2004 609

28008001 DPS_FRM_INVALID_COMMAND Reason: The DLL command specification is invalid. Application: Repeat job Measure: Check hardware / line

28008002 DPS_FRM_INVALID_PARAM Reason: The DLL command specification in invalid. Application: Repeat job Measure: Check hardware / line

28008003 DPS_FRM_ERROR_CASSETTE Reason: The deposit cassette has not been installed correctly or is not available. Measure: Install cassette. If error occurs again, insert cassette again, otherwise inform customer service.

28008004 DPS_FRM_NO_OPERATION Reason: Job cannot be executed because there is an envelope in the transport path. Application: Evaluate status information, possibly retry job.

28008005 DPS_FRM_ENVELOPE_JAM Reason: Envelope jammed in transport path Application: Evaluate status information, possibly retry job. Measure: Check transport path, remove jam.

Page 618: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

610 June 2004

28008006 DPS_FRM_ERROR_TIMEOUT Reason: The operator did not insert an envelope during the monitoring period. Application: Respond with respect to application.

28008007 DPS_FRM_ERROR_ENTRY Reason: The envelope starting the feed operation and converging the feed sensor remained in that position during the complete period of execution. The envelope left the feed area at the end of the job. Application: Log transaction and terminate it with a defined status (also for the customer).

28008008 DPS_FRM_ERROR_SHUTTER Reason: Undefined status. Defective sensor or attempt of manipulation. Application: Repeat job Measure: Check shutter for foreign matters. If error persists: call customer service.

28008009 DPS_FRM_SHUTTER_NOT_EMPTY Reason: The dispensed envelope has not been; - removed from the shutter; - inserted properly. Attempt of manipulation. Application: Draw in envelope Measure: Check shutter for foreign matters. If error persists: call customer service.

Page 619: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

June 2004 611

2800800A DPS_FRM_SHUTTER_OPEN Reason: Shutter could not be closed. Faulty sensor or attempt of manipulation. Application: Repeat job Measure: Check shutter for foreign matters. If error persists: call customer service.

2800800B DPS_FRM_OUT_OF_ENVELOPES Reason: No envelopes available any longer. Measure: Load envelopes. if error persists: inform customer service.

2800800C DPS_FRM_SIG_SDOUT Reason: The photosensor L7 (SDOUT) has no function, because of strong pollution. Measure: Check position of envelopes and load them again. If error recurs, notify Service

2800800D DPS_FRM_ERROR_PRINTER Reason: The end of the envelope was reached before all characters could be printed. This is possible if, - the envelope is shorter than expected; - the envelope was folded during transport; - the sensor is faulty. Measure: Check the hardware

2800800E DPS_FRM_ERROR_PRN_TRANSPORT Reason: Print unit motor error Measure: Call customer service, replace print unit.

Page 620: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

612 June 2004

2800800F DPS_FRM_SIG_SPHEAD Reason: "Envelope under print head" sensor could not detect envelope. Measure: Check transport route. If error appears again: call customer service, replace print unit.

28008010 DPS_FRM_SIG_SPOUT Reason: "Envelope in printer conveyor" sensor could not detect envelope. Measure: Check transport route. If error appears again: call customer service, replace print unit.

28008011 DPS_FRM_ERROR_ADD_TRANSPORT Reason: Motor problem of conveyor transport. Measure: Call customer service, replace conveyor transport.

28008012 DPS_FRM_SIG_SCINSIDE Reason: "Envelope in conveyor transport entry" sensor could not detect envelope. Measure: Check conveyor transport route. If error persists: call customer service.

28008013 DPS_FRM_SIG_SCMIDDLE Reason: "Envelope in middle of conveyor transport" sensor could not detect envelope. Measure: Check conveyor transport route. If error persists: call customer service.

28008014 DPS_FRM_SIG_SCOUT Reason: "Envelope in conveyor transport exit" sensor could not detect envelope. Measure: Check conveyor transport route. If error persists: call customer service.

Page 621: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

June 2004 613

28008015 DPS_FRM_ERROR_OUT_OF_PLACE Reason: No connection between print unit and conveyor transport. Measure: Insert print unit again. If error recurs, notify Service

28008016 DPS_FRM_ERROR_DISPENSER Reason: No envelope dispenser or programming error. Application: Change application program. Measure: Install envelope dispenser

28008017 DPS_FRM_ERROR_PRN_HEAD Reason: Print head not locked or not available. Measure: Install print head or repeat procedure. If error recurs, notify Service

28008018 DPS_FRM_ERROR_ENVELOPE_LEN Reason: The inserted envelope is too long. Application: Respond with respect to application.

28008019 DPS_FRM_ENVELOPE_NOT_FOUND Reason: No envelope was detected after a command for drawing in or dispensing an envelope. Status message

28008020 DPS_FRM_SIG_ENV Reason: Failure of "Envelope in shutter" sensor. An envelope was detected in the unit but not in the shutter. Application: Log transaction and terminate it with a defined status (also for the customer). Measure: Check shutter for foreign matters. If error persists: call customer service.

Page 622: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

614 June 2004

28008021 DPS_FRM_OPEN_BANDAGE Reason: Error when opening the bandage. The safety switch that switches the 24V may not be closed. Measure: Check the safety switch. If the error remains, call customer service, replace print unit.

28008022 DPS_FRM_CLOSE_BANDAGE Reason: Error when closing the bandage. The safety switch that switches the 24V may not be closed. Measure: Check the safety switch. If the error remains, call customer service, replace print unit.

28008023 DPS_FRM_DISPENSE_TIMEOUT Reason: The operator did not remove the offered envelope during the monitored time. Application: Respond with respect to application.

28008024 DPS_FRM_CRIT_ERROR_SHUTTER Reason: An error has occurred in the shutter. The envelope position is undetermined. It is not inside the deposit cassette. Application: Evaluate status information, possibly retry job. Measure: Check transport path, remove jam.

28008025 DPS_FRM_CRIT_ERROR_BANDAGE Reason: An error has occurred on the bandage. The envelope didn´t get into the deposit cassette. Application: Evaluate status information, possibly retry job. Measure: Check transport path, remove jam.

Page 623: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

June 2004 615

280080E8 DPS_FRM_NOT_LOADED Reason: The firmware is not loaded or started. Application: Load the appropriate firmware.

280080EA DPS_FRM_NOT_ENOUGH_MEMORY Reason: Memory for the firmware file is too short. Measure: Call customer service, check firmware file and the hardware.

280080EB DPS_FRM_FILE_CHECKSUM Reason: Checksum of the firmware file is invalid. Measure: Check the validity of the firmware file.

280080EC DPS_FRM_HARDWARE_ERROR Reason: Hardware error. Failure to program the flash memory. Measure: Call customer service, check firmware file and the hardware.

280080F0 DPS_FRM_COMMAND_CANCELED Reason: Job cancelled by CANCEL. Application: Respond with respect to application.

StWarn:

20000001 DPS_WARN_LED Reason: The device handler was configured to switch LEDs when waiting for the removal/input of an envelope. An error occurred when accessing the SEL DH to switch the LEDs. Measure: Check the configuration of DPS and SEL device handler.

Page 624: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Deposit Module (DPS)

616 June 2004

20000002 DPS_WARN_NO_FIRMWARE Reason: There is no firmware loaded or the download firmware is faulty. This warning can only occur by the API function "CscDpsOpen". Application: Load the firmware by using the API function "CscDpsInit".

20000003 DPS_WARN_FRM_FILE_ACCESS_ERROR Reason: Cannot open or read the firmware file on disk. This warning can only occur by the API function "CscDpsOpen". Measure: Check the firmware file.

20000004 DPS_WARN_FRM_FILE_DATA_ERROR Reason: The API-Function "CscDpsOpen" check the validity of the firmware file on Disk. This warning occur if a faulty firmware file was found. Measure: Check the firmware file.

Page 625: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 617

Cash-Cheque Dispenser Module (CCDM) StClass:

STCLASS_OK No error STCLASS_ERROR_CCDM Error of the CSCWCCDM.DLL

StCode:

20008000 CCDM_INVALID_PARA Reason: Invalid parameter in command. Application: Check the parameter in CscDhwPara structure.

20008001 CCDM_NO_DOCUMENT Reason: No document inserted. Application: Respond are required by application.

20008002 CCDM_MICR_NOT_SELECTED Reason: Function CscPrtRead was called, but no MICR mode via CscPrtControl selected. Application: Check application program. Inform Customer Service if error occurs again. Measure: Software error, inform service.

Page 626: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

618 June 2004

20008003 CCDM_INVALID_WINDOWS_VERSION Reason: The CCDM device handler presumes MS-Windows 2000 or MS-Windows XP. Application: Check the installed windows version. Only Windows2000 and Windows XP supported. Measure: Software error, inform service.

20008004 CCDM_PAPER_TRAY Reason: There is still a document in the scanner. Application: Move document to the reject box. Measure: Check the hardware if necessary.

20008005 CCDM_INVALID_RESPONSE Reason: The CCDM-HW send a unknown response to a command. The received V.24 data were not in the expected format. Measure: Check the hardware and the V24-connection .

20008006 CCDM_ERROR_OPEN_RAW_FILE Reason: Cannot open raw file (CCDM.RAW). Application: Check application program. Inform Customer Service if error occurs again.

20008007 CCDM_ERROR_WRITE_RAW_FILE Reason: Error writing raw file (CCDM.RAW). Application: Check application program. Inform Customer Service if error occurs again.

Page 627: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 619

20008008 CCDM_ERROR_SHUTTER_OPEN Reason: The shutter could not be opened. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

20008009 CCDM_ERROR_SHUTTER_CLOSE Reason: The shutter could not be closed. Application: Repeat the command if necessary. Measure: Check the hardware if necessary.

2000800A CCDM_INVALID_CRC Reason: Invalid CRC (check character) received with encrypted line. Application: Initialize the line again (by using the function "CscCcdmEncryption" with the specifications CCDM_ENCRYPTION_TEST and/or CCDM_ENCRYPTION_INIT_L). Measure: Check the hardware.

2000800B CCDM_INVALID_FRM_LOAD Reason: Wrong value for FRM_LOAD in Registry with [CSCCCDM]. Application: Check the parameter FRM_LOAD in Registry.

2000800C CCDM_FIRMWARE_INCOMPLETE Reason: Firmware loading could not be completed. A possible cause is that it may have been attempted to load a firmware version that was not suitable. Application: Check the configuration. Load a firmware released for the self-service system.

Page 628: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

620 June 2004

2000800D CCDM_INVALID_LED Reason: Wrong value for LED, LED_FLASH or LED_FREQ in Registry with [CSCCCDM]. Application: Check the parameters LED, LED_FLASH and LED_FREQ in file Registry.

2000800E CCDM_INVALID_DIM Reason: Wrong value for MAX_HEIGHT_CHEQUE, MAX_HEIGHT_NOTES , MAX_WIDTH_CHEQUE or MAX_WIDTH_NOTES in Registry with [CSCCCDM]. Application: Check the parameters MAX_HEIGHT_CHEQUE, MAX_HEIGHT_NOTES , MAX_WIDTH_CHEQUE or MAX_WIDTH_NOTES in file Registry.

2000800F CCDM_INVALID_CAM_COLOR Reason: Wrong value for the parameter SCAN_FRONT_RED, SCAN_FRONT_GREEN, SCAN_FRONT_BLUE, SCAN_BACK_RED, SCAN_ BACK _GREEN or SCAN_ BACK _BLUE in Registry with [CSCCCDM]. Application: Check the parameters SCAN_FRONT_RED, SCAN_FRONT_GREEN, SCAN_FRONT_BLUE, SCAN_BACK_RED, SCAN_ BACK _GREEN or SCAN_ BACK _BLUE in file Registry.

20008010 CCDM_INVALID_SHUTTER_STATE Reason: Wrong value for SHUTTER_BEHAVIOUR in Registry with [CSCCCDM]. Application: Check the parameter SHUTTER_BEHAVIOUR in file Registry.

20008011 CCDM_THREAD_START_ERROR Reason: The thread which receives the image/signature data could not started. Measure: Software error, inform service.

Page 629: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 621

20008012 CCDM_THREAD_STOP_ERROR Reason: The thread which receives the image/signature data could not stopped. Measure: Software error, inform service.

20008013 CCDM_INVALID_P36SIGPARA Reason: The pointer "pP36SigPara" is illegal. Application: Transfer a legal pointer to the device handler in the application program.

20008014 CCDM_INVALID_CHEQUEDATA Reason: The transferred cheque data (pointer, length) is illegal. Application: Transfer the cheques/sheets to the customer position. Measure: Check the hardware.

20008015 CCDM_NO_CHEQUENUMBER Reason: No cheque number received while dispensing cheques or sheets. Maybe there are cheques/sheets on the ESCROW, but it was not possible to get an image. Application: Transfer the cheques/sheets to the customer position. Measure: Check the hardware.

20008016 CCDM_ERROR_OPEN_CY_FILE Reason: An error occurred while opening a currency file. Maybe the file is configured in registry but doesn't exists in the directory %CSCROOT%\FRM. Application: Check the configuration. Measure: Configuration error, inform system administrator.

Page 630: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

622 June 2004

20008017 CCDM_ERROR_READ_CY_FILE Reason: An error occurred while opening a currency file. Maybe the file is configured in registry but doesn't exists in the directory %CSCROOT%\FRM. Application: Check the configuration. Measure: Configuration error, inform system administrator.

20008018 CCDM_ERROR_WRONG_CY_FILE Reason: The currency file is not dedicated for the installed note sensor. Application: Check the configuration. Measure: Configuration error, inform system administrator.

20008019 CCDM_ERROR_WRONG_CY_KEY Reason: A wrong keyword inside a currency file has been detected. Maybe the currency file is corrupt or not compatible to the hardware. Application: Check the configuration. Measure: Configuration error, inform system administrator.

2000801A CCDM_ERROR_CY_LOAD_NEW_EMPTY Reason: The loading of new currency data to the note sensor is only possible, if all cassettes are empty. Maybe there are notes inside the device, which are not stock of the new currency file. Application: Application specific behavior. Wiat for flushing the cassettes. Measure: Inform system administrator.

Page 631: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 623

2000801B CCDM_ERROR_CY_LOAD_NEW Reason: During the initialization of the DH a new currency file has been loaded. The application program has to read the new, modified note table and possibly assign new note id's. Only commands for which the note id's are uncritical will be accepted. Application: Read the new note table. Measure: In case of repeatedly occurrence check the application program.

2000801C CCDM_ERR_OPEN_SENS_FRM_FILE Reason: An error occurred while opening a firmware file. Maybe the file is configured in registry but doesn't exists in the directory %CSCROOT%\FRM. Application: Check the configuration. Measure: Configuration error, inform system administrator.

2000801D CCDM_ERR_RD_SENS_FRM_FILE Reason: An error occured while reading a sensor firmware file. Defective file. Application: Check configuration. Measure: Inform system administrator.

2000801E CCDM_ERR_WRONG_SENS_FRM_FILE Reason: The firmware file is not dedicated for the installed sensor. Application: Check configuration. Measure: Inform system administrator.

Page 632: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

624 June 2004

2000801F CCDM_INVALID_SENS_FRM_LOAD Reason: Wrong value for SENS_FRM_LOAD in Registry with [CSCCCDM]. Application: Check the parameter SENS_FRM_LOAD in Registry.

20008020 CCDM_ERR_WRONG_NOTE_TABLE Reason: It is not possible to read the current note table from the note sensor or the note table is empty or corrupt. Application: Application specific behaviour. Repeat the command if necessary. Measure: Hardware error. Inform Customer Service if error occurs again.

20008021 CCDM_ERR_TO_MUCH_NOTES Reason: Too much notes inserted. Only one note is allowed if the note type has been set to 'R' during the entry command. Application: Application specific behaviour. Inform the user that only one note is allowed.

20008022 CCDM_TMO_READ_SIGID Reason: Timeout while waiting for signature ID. During a dispense command one ore more L2 or L3 notes have been detected. The sensor didn't supply the signature id of one of this notes in the given time. Application: Application specific behaviour. Repeat the command if necessary. Measure: Hardware error. Inform Customer Service if error occurs again.

Page 633: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 625

20008023 CCDM_INVALID_CHEQUE_COUNT Reason: A difference between the number of cheques on ESCROW and the number of scanned cheques detected. During a dispense command one ore more scanned cheques did not reach the ESCROW. Application: Application specific behaviour. Cancel the transaction. Measure: Hardware error or jam.

20008024 CCDM_ERR_UNPROCCESSED_SHEETS Reason: A previous transaction didn't finished faultless. Cheques or sheets from this transaction are detected on ESCROW. An new entry is not possible in this situation. Application: Application specific behaviour. Transport the content of the ESCROW to a box or return it to the customer.

20008025 CCDM_ERR_UNPROCCESSED_NOTES Reason: A previous transaction didn't finished faultless. Notes from this transaction are detected on ESCROW. An new entry is not possible in this situation. Application: Application specific behaviour. Transport the content of the ESCROW to a box or return it to the customer.

20008026 CCDM_ERR_OPEN_FRM_FILE Reason: An error occurred while opening a sensor firmware file. Maybe the file is configured in registry but doesn't exists in the directory %CSCROOT%\FRM. Application: Check the configuration. Measure: Configuration error, inform system administrator.

Page 634: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

626 June 2004

20008027 CCDM_ERR_RD_FRM_FILE Reason: An error occured while reading a CCDM firmware file. May be the file is corrupt. Application: Check the configuration. Measure: Inform system administrator.

20008030 CCDM_P36_ERR_CHKSUM Reason: The checksum of the signature data of a note is wrong. A possible reason is a V24 transmission error. Application: Application specific behaviour.

20009201 CCDM_IMACON_ERROR_SYNTAX Reason: Illegal arguments calling IMACON.DLL. Application: Check application program. Inform Customer Service if error occurs again.

20009202 CCDM_IMACON_ERROR_INPUT_OPEN Reason: Cannot open input file. Application: Check application program. Inform Customer Service if error occurs again.

20009203 CCDM_IMACON_ERROR_INPUT_READ Reason: Error reading input. Application: Check application program. Inform Customer Service if error occurs again.

Page 635: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 627

20009204 CCDM_IMACON_ERROR_OUTPUT_OPEN Reason: Cannot open output file. Application: Check application program. Inform Customer Service if error occurs again.

20009205 CCDM_IMACON_ERROR_OUTPUT_WRITE Reason: Error writing output file. Application: Check application program. Inform Customer Service if error occurs again.

20009206 CCDM_IMACON_ERROR_MEMORY Reason: Not enough memory. Application: Check application program. Inform Customer Service if error occurs again.

20009207 CCDM_IMACON_ERROR_TOO_LONG Reason: Image too long. Application: Check application program. Inform Customer Service if error occurs again.

20009208 CCDM_IMACON_ERROR_TOO_LARGE Reason: Image too large (for TIF). Application: Check application program. Inform Customer Service if error occurs again.

20009209 CCDM_IMACON_ERROR_TOO_SMALL Reason: Image too small (<1 row). Application: Check application program. Inform Customer Service if error occurs again.

Page 636: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

628 June 2004

2000920A CCDM_IMACON_ERROR_TIFFCONV Reason: Error in final conversion step. Application: Check application program. Inform Customer Service if error occurs again.

2000920B CCDM_IMACON_ERROR_TEMPFILE Reason: Error in temp file access. Application: Check application program. Inform Customer Service if error occurs again.

2000920C CCDM_IMACON_ERROR_DLL_LOAD Reason: Error loading imareco.dll. Application: Check application program. Inform Customer Service if error occurs again.

200092E0 CCDM_IMACON_ERROR_JPG Reason: IMACON.DLL returns an error while generation of JPG image. Application: Check application program. Inform Customer Service if error occurs again.

200092F0 CCDM_IMACON_ERROR_RECO Reason: IMACON.DLL returns an error while generation of recognition data. Application: Check application program. Inform Customer Service if error occurs again.

200092FF CCDM_IMACON_UNDEF_ERROR Reason: IMACON.DLL returned undefined error. Application: Check application program. Inform Customer Service if error occurs again.

Page 637: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 629

20009300 CCDM_DQF_ERR_ILLEGAL_PARAM Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

20009301 CCDM_DQF_ERR_NO_MEMORY Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

20009302 CCDM_DQF_ERR_HGHLOW_INVALID Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

20009303 CCDM_DQF_ERR_LOWEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

20009304 CCDM_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

20009305 CCDM_DQF_ERR_SENSITIVNESS_RANGE Reason: Internal error while calling DQF.DLL. Measure: Inform Customer Service if error occurs again.

Page 638: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

630 June 2004

200093FF CCDM_DQF_UNDEF_ERROR Reason: DQF.DLL returned undefined error. Measure: Check application program. Inform Customer Service if error occurs again.

2800F000 CCDM_FRM_SW_MISSING Reason: The firmware is not loaded in the CCDM. Application: Load the firmware.

2800F001 CCDM_FRM_SYNTAX Reason: The parameters of the command have a wrong syntax. Application: Check the parameters of the last API function call.

2800F002 CCDM_FRM_DEVICE_NOT_READY Reason: One of the locks is active or an error occurred that requires a corrective operator action. Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F003 CCDM_FRM_ERROR Reason: An error occurred during the execution of the command. Measure: Check the status of the device to inquire the reason and react according to the reason.

2800F004 CCDM_FRM_DOOR_NOT_OPEN Reason: The safe door must be open for the execution of the actual command (switching the encryption on/off). Measure: Open the safe door.

Page 639: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 631

2800F005 CCDM_FRM_CONTEXT Reason: The command cannot be executed at this point of time or a special HW component is missing or not configured. Application: Check the status to see, if this command can be executed. Measure: Check the hardware and the configuration.

2800F006 CCDM_FRM_NO_BUNDLE_AVAILABLE Reason: The application program tried to dispense a bundle, but the IO-tray is empty. Software error. Application: Check the application program.

2800F007 CCDM_FRM_BUNDLE_NOT_REMOVED Reason: Customer did not remove the bundle until the command has timed out. Application: Application specific behaviour. Repeat the command if necessary.

2800F008 CCDM_FRM_ENTRY Reason: Cheques or sheets are not correct inserted. Application: Application specific behaviour. Repeat the command if necessary.

2800F009 CCDM_FRM_BOOT Reason: The CCDM firmware initiated a boot. Possible reason are: The safty switch has been closed, the RESET button has been pressed or an internal firmware error occurred during a command. Application: Poll the CCDM by using the command CscCcdmReadStatus(..) to detect the status of the device. The further proceeding depends from the situation. ( Notes,sheets inside the device? )

Page 640: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

632 June 2004

2800F00A CCDM_SENS_HW_ERROR Reason: The note sensor module reported a hardware error. Application: Application specific behaviour. Repeat the command if necessary. Measure: Check the note sensor.

2800F00B CCDM_SENS_FRM_ERROR Reason: The note sensor module reported a firmware error. Application: Application specific behaviour. Repeat the command if necessary. Measure: Check the note sensor. Reload the sensor firmware.

2800F00C CCDM_SENS_COM_ERROR Reason: An comunication error has been reported by the sensor module Application: Application specific behaviour. Repeat the command if necessary. Measure: Check the note sensor.

2800F00D CCDM_SENS_DATA_ERROR Reason: The note sensor detected an error in the data format. Possible reasons are: Currency data corrupt, signature data of a note wrong. Application: Application specific behaviour. Repeat the command if necessary. Check the application program. Measure: Check the note sensor. Reload the sensor firmware or the note table.

Page 641: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 633

2800F00E CCDM_SENS_NOTE_TAB_ERROR Reason: The note sensor detected an error in the note table. Possible reasons are: Note table full, Note table corrupt. Application: Application specific behaviour. Repeat the command if necessary. Check the application program. Measure: Check the installed note memory modules and the currency files.

2800F00F CCDM_FRM_SENS_WRONG_NOTE_ASSIGN Reason: The assignment of a note is wrong. Possible reasons: The application tried to assign a id less than 1 or greater than 254; or the sended note table cantains the same id for different currencies or different denominations. Application: Application specific behaviour. Check the application program. Measure: Check the application program and the relevant registry keys.

2800F010 CCDM_SENS_READER_ERROR Reason: The sensor couldn't read the document (note or cheque). Adverse light conditions during the sheet scanning. Application: Application specific behaviour. Repeat the command if necessary. Measure: Check the sensor module. Beware of improper oerating. Close all doors to prevent adverse light conditions.

2800F011 CCDM_SENS_DOWNLOAD_ERROR Reason: An error occured during downloding of firmware or currency data. May be, the firmware or currency file is not capable for this sensor. Application: Application specific behaviour. Repeat the command if necessary. Check the configuration. Measure: If it is a correct firmware or currency file check the sensor module. Reload the sensor firmware.

Page 642: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

634 June 2004

2800F012 CCDM_SENS_UNKNOWN_ERROR Reason: The sensor responded with an unknown error code. Application: Application specific behaviour. Repeat the command if necessary. Check the configuration. Measure: Check the sensor module. Reload the sensor firmware. Inform the system administrator.

2800F0A0 CCDM_FRM_TRAY_METAL Reason: Bundle with detected metal in tray. Application: At next the application has to eject the bundle.

2800F0A1 CCDM_FRM_TRAY_NOT_DISPENSED Reason: Tray is occupied with not dispensable notes or cheques. Application: Application specific behaviour.

2800F0A2 CCDM_FRM_TRAY_ERROR Reason: A not specified tray error occurred. Application: Application specific behaviour. Repeat the command if necessary.

2800F0A3 CCDM_FRM_SHUTTER_ERROR Reason: Shutter error while the command CscCcdmCashIn. Application: Application specific behaviour. Repeat the command if necessary.

2800F0A4 CCDM_FRM_ESCROW_EMPTY Reason: CscCcdmTransport command received, but the ESCROW is empty. (nothing to transport!). Application: Application specific behaviour.

Page 643: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 635

2800F0A5 CCDM_FRM_ESCROW_FULL Reason: ESCROW full while dispending a bundle. Application: Application specific behaviour. Perform transport command.

2800F0A6 CCDM_FRM_ESCROW_READY Reason: Cheques or sheets on ESCROW while performing the next transaction. Application: Application specific behaviour.

2800F0A7 CCDM_FRM_ESCROW_JAM Reason: Cheques or notes jammed on the ESCROW. Application: Application specific behaviour. Repeat the command if necessary. Measure: Check the hardware. Inform service.

2800F0A8 CCDM_FRM_COMPONENT_NOT_AVAILABLE Reason: There exists no hardware equipment to perform the requested command. E.g. The application tried to dispense notes, but the CCDM is not equipped with a note checker. Application: Transfer the cheques/sheets to the customer position. Measure: Check the hardware. Inform service.

StWarn

2800E000 CCDM_WARN_ENTRY_HANDLING Reason: Tray operating error (e.g. banknotes not correct inserted). Application: Application specific behaviour. Repeat the last command if necessary.

Page 644: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

636 June 2004

2800E001 CCDM_WARN_BUNDLE_NOT_INSERTED Reason: This status will be returned by the CscwCcdmEntry(..) command and tells the application that the customer didn't insert sheets in the given time. (Time Out) Application: Application specific behaviour.

2800E002 CCDM_WARN_BUNDLE_NOT_REMOVED Reason: This is a status that tells the application that no (or not all) banknotes or cheques have been taken by the customer. It will be returned by the command CscwCcdmEject(...). Application: Application specific behaviour.

2800E003 CCDM_WARN_BUNDLE_REMOVED Reason: This status tells the application that banknotes or cheques have been taken by the customer while retract to IO or box. Application: Application specific behaviour.

2800E004 CCDM_WARN_SHEETS_AVAILABLE Reason: There are sheets available in the IO tray, e.g. rejected notes or cheques after dispensing. Application: Eject the content of the IO tray before performing the command.

2800E00A CCDM_NO_ACTUAL_FIRMWARE Reason: The loaded firmware is older than the firmware found on the disk. Application: Load the actual firmware by using the API function "CscCcdmInit".

2800E00B CCDM_NO_FIRMWARE Reason: There is no firmware loaded into the CCCDM. Application: Load the firmware by using the API function "CscCcdmInit".

Page 645: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Cash-Cheque Dispenser Module (CCDM)

June 2004 637

2800E00C CCDM_WARN_LED Reason: The device handler was configured to switch LEDs when customer action is necessary. An error occurred when accessing the SEL DH to switch the LEDs. Application: Check the configuration of CCDM and SEL device handler.

2800E010 CCDM_WARN_CY_NEW Reason: Return of the function CscCcdmInit() if a new currency file has been detected on the hard disk and the data has been loaded into the sensor. May be the note assignment has changed. In the next step the application program has to read the modified note table and send a new note assignment to the reader. Only commands for which the note assignment is uncritical will be accepted. Any other command will be returned with the error code CCDM_ERROR_CY_LOAD_NEW. Application: Read the new currency table and send a new note assignment.

2800E011 CCDM_WARN_CY_NEW_EMPTY Reason: Returned by the function CscCcdmInit() if a new currency file has been detected. The administrator has to flush all cassettes before loading the new currency data. Application: Application specific behaviour. Initiate the loading of currency files.

2800E014 CCDM_WARN_FRM_NEW Reason: One or more new firmware loaded automatically by the Device Handler. Application: Application specific behaviour.

2800E015 CCDM_WARN_CY_INCONSISTENT Reason: The currently loaded note table is inconsistent to the sensor-firmware. Application: The application must load the correct currency file appropriate to the just loaded sensor firmware.

Page 646: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

638 June 2004

Page 647: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 639

CCDM: extended error codes 29020014 CCDM_EXT_ERR_020

Reason: General firmware error. Measure: Inform system administrator.

29050001 CCDM_EXT_ERR_001 Reason: No connection to dispenser module. Measure: Inform system administrator.

29060002 CCDM_EXT_ERR_002 Reason: No connection to amplifier logic. Measure: Inform system administrator.

29070003 CCDM_EXT_ERR_003 Reason: o connection to stacker logic. Measure: Inform system administrator.

29080015 CCDM_EXT_ERR_021 Reason: Battery on controller board empty. Measure: Inform system administrator.

Page 648: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

640 June 2004

29090018 CCDM_EXT_ERR_024 Reason: Device configuration of controller incorrect or missing. Measure: Inform system administrator.

290C0016 CCDM_EXT_ERR_022 Reason: Safety switch active. Measure: Inform system administrator.

29110017 CCDM_EXT_ERR_023 Reason: Data transfer on RS 232 interface. Measure: Wait for the data communication.

29120019 CCDM_EXT_ERR_025 Reason: The application overloads the CCDM hardware ( too many reset commands per time unit). Measure: Inform system administrator.

29130090 CCDM_EXT_ERR_144 Reason: - Mechanical blocking (foreign matter) - Plug has not been plugged in - Shutter is defective Measure: Inform system administrator.

29140091 CCDM_EXT_ERR_145 Reason: Error on metal detection unit. Measure: Inform system administrator.

Page 649: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 641

29150078 CCDM_EXT_ERR_120 Reason: Error on swivel transport unit or in the area of the bundle alignment. Measure: Inform system administrator.

29150079 CCDM_EXT_ERR_121 Reason: Error on swivel transport unit or in the area of the bundle alignment. Measure: Inform system administrator.

2915007A CCDM_EXT_ERR_122 Reason: Error on swivel transport unit or in the area of the bundle alignment. Measure: Inform system administrator.

29150082 CCDM_EXT_ERR_130 Reason: Error on swivel transport unit or in the area of the bundle alignment. Measure: Inform system administrator.

29160064 CCDM_EXT_ERR_100 Reason: Media jam in dispenser module. Transport error detected before dispensing. Measure: Inform system administrator.

2916006C CCDM_EXT_ERR_108 Reason: Media jam in dispenser module. Transport error detected before dispensing. Measure: Inform system administrator.

Page 650: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

642 June 2004

2916006F CCDM_EXT_EER_111 Reason: Media jam in dispenser module. Transport error detected before dispensing. Measure: Inform system administrator.

29160070 CCDM_EXT_ERR_112 Reason: Media jam in dispenser module. Transport error detected before dispensing. Measure: Inform system administrator.

291600B5 CCDM_EXT_ERR_181 Reason: Media jam in dispenser module. Transport error detected before dispensing. Measure: Inform system administrator.

29180065 CCDM_EXT_ERR_101 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29180066 CCDM_EXT_ERR_102 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29180067 CCDM_EXT_ERR_103 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

Page 651: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 643

29180069 CCDM_EXT_ERR_105 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

2918006A CCDM_EXT_ERR_106 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

2918006E CCDM_EXT_ERR_110 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29180071 CDDM_EXT_ERR_113 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29180072 CCDM_EXT_ERR_114 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29180073 CCDM_EXT_ERR_115 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

Page 652: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

644 June 2004

291800C9 CCDM_EXT_ERR_201 Reason: Paper jam detected during separation process. Measure: Inform system administrator.

29190096 CCDM_EXT_ERR_150 Reason: Error of hall sensors. Measure: Inform system administrator.

29190097 CCDM_EXT_ERR_151 Reason: Hall sensor error. Measure: Inform system administrator.

291A0074 CCDM_EXT_ERR_116 Reason: Media jam in reject transport area. Measure: Inform system administrator.

291A00B4 CCDM_EXT_ERR_180 Reason: Media jam in reject transport area. Measure: Inform system administrator.

291B008C CCDM_EXT_ERR_140 Reason: Error on the cam disk. Measure: Inform system administrator.

Page 653: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 645

291B008D CCDM_EXT_ERR_141 Reason: Error on the cam disk. Measure: Inform system administrator.

291C00C8 CCDM_EXT_ERR_200 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

291C00CA CCDM_EXT_ERR_202 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

291C00CB CCDM_EXT_ERR_203 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

291C00CC CCDM_EXT_ERR_204 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

291C00CD CCDM_EXT_ERR_205 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

Page 654: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

646 June 2004

291C00CE CCDM_EXT_ERR_206 Reason: Media jam in front of or in the alignment station. Measure: Inform system administrator.

291E001E CCDM_EXT_ERR_030 Reason: Error magnetic character reader. Measure: Inform system administrator.

291F0028 CCDM_EXT_ERR_040 Reason: Error cheque/cash reader. Measure: Inform service.

291F0032 CCDM_EXT_ERR_050 Reason: BEB module is defective. Measure: Inform service.

2920002D CCDM_EXT_ERR_045 Reason: External light in cheque/cash reader. Measure: Inform system administrator.

29200035 CCDM_EXT_ERR_053 Reason: External light in cheque/cash reader. Measure: Inform system administrator.

Page 655: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 647

29210029 CCDM_EXT_ERR_041 Reason: Communication problems with cheque/cash reader. Measure: Inform system administrator.

2921002A CCDM_EXT_ERR_042 Reason: Communication problems with cheque/cash reader. Measure: Inform system administrator.

2921002B CCDM_EXT_ERR_043 Reason: Communication problems with cheque/cash reader. Measure: Inform system administrator.

2921002C CCDM_EXT_ERR_044 Reason: BEB note table configuration not Ok. Measure: Inform system administrator.

29210033 CCDM_EXT_ERR_051 Reason: BEB firmware error. Measure: Inform system administrator.

29210034 CCDM_EXT_ERR_052 Reason: BEB syntax error. Measure: Inform system administrator.

Page 656: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

648 June 2004

2922002F CCDM_EXT_ERR_047 Reason: Communication problems (time out) RS232 interface <-> cheque/cash reader Measure: Inform system administrator.

29220030 CCDM_EXT_ERR_048 Reason: Communication problem from BEB to RS232 interface. Measure: Inform system administrator.

29220031 CCDM_EXT_ERR_049 Reason: BEB firmware and CCDM firmware are incompatible. Measure: Inform system administrator.

29220036 CCDM_EXT_ERR_054 Reason: Communication problems RS232 interface <-> BEB module Measure: Inform system administrator.

29220037 CCDM_EXT_ERR_055 Reason: BEB module not mounted or not properly connected to the backplane. Measure: Inform system administrator.

29220038 CCDM_EXT_ERR_056 Reason: BEB firmware and CCDM firmware are incompatible. Measure: Inform system administrator.

Page 657: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 649

29280136 CCDM_EXT_ERR_310 Reason: Media jam in sensor transport. Measure: Inform system administrator.

29280137 CCDM_EXT_ERR_311 Reason: Media jam in sensor transport. Measure: Inform system administrator.

29280138 CCDM_EXT_ERR_312 Reason: Media jam in sensor transport. Measure: Inform system administrator.

29280139 CCDM_EXT_ERR_313 Reason: Document jam in enterance area of sensor transport unit. Measure: Inform system administrator.

29280144 CCDM_EXT_ERR_324 Reason: Media jam in sensor transport. Measure: Inform system administrator.

2928014D CCDM_EXT_ERR_333 Reason: Media jam in sensor transport. Measure: Inform system administrator.

Page 658: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

650 June 2004

292801F5 CCDM_EXT_ERR_501 Reason: Deflector in wrong position. Measure: Inform system administrator.

292801F6 CCDM_EXT_ERR_502 Reason: Jam between sensor transport (paper deflecting units) and in front of RLS1. Measure: Inform system administrator.

29290140 CCDM_EXT_ERR_320 Reason: Document jam between ALS1 and SLS1. Measure: Inform system administrator.

29290141 CCDM_EXT_ERR_321 Reason: Malfunction of the 3-way deflector (during transport from alignment station). Measure: Inform system administrator.

29290142 CCDM_EXT_ERR_322 Reason: Malfunction of the 3-way deflector (during transport from the escrow unit). Measure: Inform system administrator.

29290143 CCDM_EXT_ERR_323 Reason: Document jam in the area SLS1 -> document deflecting units -> escrow unit /reject transport. Measure: Inform system administrator.

Page 659: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 651

292A012D CCDM_EXT_ERR_301 Reason: Media jam in sensor transport at the 3-way deflector. Measure: Inform system administrator.

292B012E CCDM_EXT_ERR_302 Reason: Media jam in sensor transport at the reject deflector. Measure: Inform system administrator.

292E014C CCDM_EXT_ERR_332 Reason: Document jam between sensor transport and reject transport. Measure: Inform system administrator.

292E01F7 CCDM_EXT_ERR_503 Reason: Document jam between sensor transport and reject transport. Measure: Inform system administrator.

292E01F8 CCDM_EXT_ERR_504 Reason: Document jam between sensor transport and reject transport. Measure: Inform system administrator.

292F00AA CCDM_EXT_ERR_170 Reason: Initialization error of reject transport. Measure: Inform system administrator.

Page 660: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

652 June 2004

2930014B CCDM_EXT_ERR_331 Reason: Document jam between sensor transport and deposit / reject transport. Measure: Inform system administrator.

29300259 CCDM_EXT_ERR_601 Reason: Document jam between sensor transport and deposit / reject transport. Measure: Inform system administrator.

2930025A CCDM_EXT_ERR_602 Reason: Document jam between sensor transport and deposit / reject transport. Measure: Inform system administrator.

2932014A CCDM_EXT_ERR_330 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29320192 CCDM_EXT_ERR_402 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29320193 CCDM_EXT_ERR_403 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

Page 661: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 653

29320194 CCDM_EXT_ERR_404 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29320195 CCDM_EXT_ERR_405 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29320196 CCDM_EXT_ERR_406 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29320258 CCDM_EXT_ERR_600 Reason: Document jam at the escrow unit. Measure: Inform system administrator.

29330190 CCDM_EXT_ERR_400 Reason: Torn band or full drum; tape no longer under ESL2. Measure: Inform service.

29340191 CCDM_EXT_ERR_401 Reason: Band torn; tape no longer under ELS2. Measure: Inform service.

Page 662: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

654 June 2004

293C0041 CCDM_EXT_ERR_065 Reason: Error photosensor VLS10 Measure: Inform system administrator.

293D003D CCDM_EXT_ERR_061 Reason: Error photosensor VLS1 Measure: Inform system administrator.

293E0040 CCDM_EXT_ERR_064 Reason: Error photosensor VLS7 Measure: Inform system administrator.

293F003E CCDM_EXT_ERR_062 Reason: Error photosensor VLS2 Measure: Inform system administrator.

293F004D CCDM_EXT_ERR_077 Reason: Error photosensor VLS12 Measure: Inform system administrator.

2940003F CCDM_EXT_ERR_063 Reason: Error photosensor VLS6 Measure: Inform system administrator.

Page 663: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 655

2941004B CCDM_EXT_ERR_075 Reason: Error photosensor VLS11 Measure: Inform system administrator.

29420044 CCDM_EXT_ERR_068 Reason: Error photosensor ALS3 Measure: Inform system administrator.

29430045 CCDM_EXT_ERR_069 Reason: Error photosensor ALS4 Measure: Inform system administrator.

29440043 CCDM_EXT_ERR_067 Reason: Error photosensor ALS2 Measure: Inform system administrator.

29450042 CCDM_EXT_ERR_066 Reason: Error photosensor ALS1 Cover of alignment station is not closed. Measure: Inform system administrator.

29460047 CCDM_EXT_ERR_071 Reason: Error photosensor SLS3 Magnetic character reader not closed. Measure: Inform system administrator.

Page 664: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

656 June 2004

29470046 CCDM_EXT_ERR_070 Reason: Error photosensor SLS1 Measure: Inform system administrator.

29480048 CCDM_EXT_ERR_072 Reason: Error photosensor ELS1 Measure: Inform system administrator.

2949004C CCDM_EXT_ERR_076 Reason: Error photosensor ELS5 Measure: Inform system administrator.

294A0049 CCDM_EXT_ERR_073 Reason: Error photosensor RLS1 Measure: Inform system administrator.

294B004A CCDM_EXT_ERR_074 Reason: Error photosensor RLS2 Measure: Inform system administrator.

29500050 CCDM_EXT_ERR_080 Reason: Error photosensor KLS2 Measure: Inform system administrator.

Page 665: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 657

29510051 CCDM_EXT_ERR_081 Reason: Error photosensor KLS3 Measure: Inform system administrator.

29520052 CCDM_EXT_ERR_082 Reason: Error photosensor KLS8 Measure: Inform system administrator.

29530053 CCDM_EXT_ERR_083 Reason: Error photosensor KLS11 Measure: Inform system administrator.

29540054 CCDM_EXT_ERR_084 Reason: Error photosensor KLS1_5 Measure: Inform system administrator.

29550055 CCDM_EXT_ERR_085 Reason: Error photosensor KLS2_5 Measure: Inform system administrator.

295A025B CCDM_EXT_ERR_603 Reason: Incorrect position of deflector in transfer unit. Measure: Inform system administrator.

Page 666: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

658 June 2004

295A025C CCDM_EXT_ERR_604 Reason: Incorrect position of deflector in transfer unit. Measure: Inform system administrator.

295A025E CCDM_EXT_ERR_606 Reason: Incorrect position of deflector in transfer unit. Measure: Inform system administrator.

295A0261 CCDM_EXT_ERR_609 Reason: Incorrect position of deflector in transfer unit. Measure: Inform system administrator.

295A0264 CCDM_EXT_ERR_612 Reason: Incorrect position of deflector in transfer unit. Measure: Inform system administrator.

295B0266 CCDM_EXT_ERR_614 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

295B026A CCDM_EXT_ERR_618 Reason: Deflector (cassette 1 / cassette 2) is not functioning Measure: Inform system administrator.

Page 667: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

June 2004 659

295C0260 CCDM_EXT_ERR_608 Reason: Incorrect position of deflector in cassette module 1. Measure: Inform system administrator.

295C0262 CCDM_EXT_ERR_610 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

295D0267 CCDM_EXT_ERR_615 Reason: Error in cassette 1. Measure: Inform service.

295E0263 CCDM_EXT_ERR_611 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

295E0265 CCDM_EXT_ERR_613 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

295F0268 CCDM_EXT_ERR_616 Reason: Error in cassette 2. Measure: Inform service.

Page 668: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

CCDM: extended error codes

660 June 2004

2960025D CCDM_EXT_ERR_605 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

2960025F CCDM_EXT_ERR_607 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

29600269 CCDM_EXT_ERR_617 Reason: Incorrect position of deflector in cassette module. Measure: Inform system administrator.

Page 669: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 661

Money Door Module (MDM) StClass:

STCLASS_OK No error STCLASS_ERROR_MDM Error of the CSCWMDM.DLL

StCode:

20008100 MDM_MEMORY_ALLOC_ERROR Reason: OS/2 report an error when requesting memory for a data buffer. Application: Check the application program Measure: Check memory configuration of the PC hardware, check disc space.

20008101 MDM_LB_NOT_INSTALLED Reason: The status of a non-existent light barrier was requested. Application: Check the application program Measure: Check CSC.INI [BUILDOUT] Check the hardware

20008102 MDM_COMMUNICATION_ERROR Reason: The MDM hardware does not respond at OPEN. Measure: Check the V.24 line to the MDM hardware.

Page 670: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Money Door Module (MDM)

662 June 2004

20008FFF MDM_INVALID_ERROR_DATA Reason: Internal error. Possible hardware error. Measure: Check the hardware. Report the trace log of this entry to Service.

28008020 MDM_WRONG_BLOCK_ID Reason: Block ID wrong (internal error) Measure: Check software and firmware release.

28008021 MDM_WRONG_DEVICE_ID Reason: Device number wrong (internal error) Measure: Check software and firmware release.

28008022 MDM_WRONG_JOB_SPEC Reason: Job specification wrong (internal error) Measure: Check software and firmware release.

28008023 MDM_SMALL_REC_BUFF Reason: Return buffer too small (internal error) Measure: Check software and firmware release.

28008024 MDM_ERROR_JOB_SPEC Reason: Syntax error in job specification (internal error) Measure: Check software and firmware release.

Page 671: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Money Door Module (MDM)

June 2004 663

28008025 MDM_JOB_NOT_READY Reason: The last command has not been processed yet. Application: Wait for processing to be completed and repeat the command. If necessary, change the application program.

28008030 MDM_DOOR_NOT_OPENED Reason: The door could not be fully opened. Cash was not accessible to customer. Application: Repeat the command after a short delay, as the door may have been blocked externally. Measure: If the error occurs again, have the hardware checked by Service.

28008031 MDM_DOOR_NOT_CLOSED Reason: Door cannot be closed completely Door is blocked (by operator/customer or object) Application: Repeat job after a short pause. When the door can be closed, repeat job. When the door still does not close, close door before next transaction. End application if error recurs Measure: Repeat "Door close" job. If error remains, notify Service.

28008040 MDM_GENERAL_HW_ERROR Reason: The hardware error cannot be specified closer. Measure: Have the hardware checked by Service.

Page 672: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Money Door Module (MDM)

664 June 2004

28008041 MDM_EPROM_FAILURE Reason: E-PROM faulty Application: End application Measure: Have the hardware checked by Service.

28008042 MDM_EEPROM_FAILURE Reason: EE-PROM faulty Application: End application Measure: Have the hardware checked by Service.

28008043 MDM_PROCESSOR_FAILURE Reason: Processor faulty Application: End application Measure: Have the hardware checked by Service.

28008045 MDM_LB_FAILURE Reason: One or more light barriers are dirty or faulty. Application: End application Measure: Clean the light barriers. If the error occurs again, have the hardware checked by Service.

Page 673: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Money Door Module (MDM)

June 2004 665

28008046 MDM_WAIT_EXCEEDED Reason: This message only occurs when the "Door open" job or "Door close" was issued more than three times quickly. Application: Issue job again after 30 sec. Abort application if error occurs again. Measure: Have the hardware checked by Service.

StWarn:

28008050 LB_LIMIT Reason: The values of one or a number of light barriers are below the minimum value. Measure: Clean the light barriers. If the warning occurs again, have the hardware checked by Service.

28008051 LIGHT_FAILURE Reason: The light bulb in the cash output tray is defective. Measure: Replace the light bulb

28008052 MDM_DOOR_N_COMPLETE_OPENED Reason: Door does not reach the "open" end position when opened. CASH WAS ACCESSIBLE TO CUSTOMER !!! Application: Repeat the job Measure: Have mechanism checked by Customer Service if error occurs again.

Page 674: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

666 June 2004

Page 675: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 667

Panel Protection Door (PPD) StClass:

STCLASS_OK No error STCLASS_ERROR_PPD Error of the CSCWPPD.DLL

StCode:

20008000 PPD_UNDEF_FRM_ERROR Reason: An unknown internal error has occurred in the firmware. Measure: Check the hardware

20008101 PPD_MEMORY_ALLOC_ERROR Reason: OS/2 reports an error when requesting memory for a data buffer. Application: Check the application program Measure: Check memory configuration of the PC hardware, check disk space.

20008102 PPD_INVALID_RX_DATA Reason: Wrong/undefined character job acknowledgment. Application: Repeat the job. Measure: Check the firmware release.

Page 676: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

668 June 2004

20008103 PPD_INVALID_FRM_DATA Reason: Invalid data in response from peripheral controller. Measure: Check configuration.

20008104 PPD_INVALID_FRM_FILE_MOD Reason: Invalid MODSEG ID in FRM file on the system. Measure: Check configuration.

20008105 PPD_CTF_FILE_NOT_FOUND Reason: The file *.CTF was not found in the directory <CSCROOT>\FRM. Measure: Check configuration.

20008106 PPD_FRM_FILE_NOT_FOUND Reason: The file *.FRM was not found in the directory <CSCROOT>\FRM. Measure: Check configuration.

20008107 PPD_CTF_FILE_OPEN_FAILED Reason: Error when opening a *.CTF file. Measure: Check configuration.

20008108 PPD_FRM_FILE_OPEN_FAILED Reason: Error when opening a *.FRM file. Measure: Check configuration.

Page 677: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

June 2004 669

20008109 PPD_INVALID_CTF_FILE_DATA Reason: Invalid data in teh *.CTF file. Measure: Check CTF file.

28008020 PPD_FRM_INVALID_BLOCK_ID Reason: Block ID wrong (internal error) Measure: Check software and firmware release.

28008021 PPD_FRM_INVALID_DEV_ID Reason: Device number wrong (internal error) Measure: Check software and firmware release.

28008022 PPD_FRM_INVALID_JOB_ID Reason: Job specification wrong (internal error) Measure: Check software and firmware release.

28008023 PPD_FRM_INVALID_BUFFER_LEN Reason: Job longer than receive buffer (internal error) Measure: Check software and firmware release.

28008024 PPD_FRM_INVALID_JOB Reason: Syntax error in job specification (internal error) Measure: Check software and firmware release.

Page 678: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

670 June 2004

28008030 PPD_FRM_MOTION_ERROR Reason: No motion messages when door is opened. Measure: Check the mechanics and sensor. Inform customer Service.

28008040 PPD_FRM_GENERAL_HW_ERROR Reason: The hardware error cannot be specified closer. Measure: Have the hardware checked by Service.

28008041 PPD_FRM_EPROM_ERROR Reason: E-PROM faulty Application: End application Measure: Have the hardware checked by Service.

28008043 PPD_FRM_PROCESSOR_FAILURE Reason: Processor faulty Application: End application Measure: Have the hardware checked by Service.

28008044 PPD_FRM_CHECKSUM_ERROR Reason: Checksum error in hardware RAM. Application: Reboot system. Measure: Inform customer Service. Replace the hardware.

Page 679: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

June 2004 671

280080E0 PPD_FRMLD_INVALID_BLK_LEN_CHAR Reason: Characters 1-3 (block length) not equal to decimal digits. Measure: Check SW and firmware release. If necessary, check the hardware.

280080E1 PPD_FRMLD_INVALID_BLK_LEN Reason: Block length not in valid area (3-250). Measure: Check SW and firmware release. If necessary, check the hardware.

280080E2 PPD_FRMLD_INVALID_BLK Reason: Block length specification not equal to received block length. Measure: Check SW and firmware release. If necessary, check the hardware.

280080E3 PPD_FRMLD_INVALID_BLK_ID Reason: Invalid Block ID (N,E). Measure: Check SW and firmware release. If necessary, check the hardware.

280080E4 PPD_FRMLD_INVALID_DEV_ID Reason: Invalid Device ID Measure: Check SW and firmware release. If necessary, check the hardware.

280080E5 PPD_FRMLD_INVALID_COMMAND Reason: Invalid Job ID Measure: Check SW and firmware release. If necessary, check the hardware.

Page 680: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

672 June 2004

280080E6 PPD_FRMLD_INVALID_CMD_PARA Reason: Invalid Job parameter Measure: Check SW and firmware release. If necessary, check the hardware.

280080E7 PPD_FRM_JOB_NOT_READY Reason: The last command has not been processed yet. Application: Wait for processing to be completed and repeat the command. If necessary, change the application program.

280080E8 PPD_FRM_NOT_LOAD Reason: Firmware not loaded or started. Application: If the error occurs at OPEN, check the firmware-dependent files and the configuration. Boot the system. Measure: Inform customer Service. Replace the hardware.

280080E9 PPD_FRMLD_INVALID_FILE_LEN Reason: Wrong file length Measure: Check firmware and configuration.

280080EA PPD_FRMLD_INVALID_MEM Reason: Memory for program module too small. Measure: Check firmware and configuration.

Page 681: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

June 2004 673

280080EB PPD_FRMLD_INVALID_FILE_CRC Reason: Invalid file check character Measure: Check firmware and configuration.

280080EC PPD_FRMLD_HW_ERROR Reason: Hardware not functioning/faulty. Measure: Check the hardware.

StWarn:

28008050 PPD_NOT_COMPLETE_OPENED Reason: The door could not be fully opened. Door is blocked (by operator/customer or object) Application: Repeat the command after a short delay, as the door may have been blocked externally. Measure: If the error occurs again, have the hardware checked by Service.

28008051 PPD_NOT_COMPLETE_CLOSED Reason: Door cannot be closed completely. Door is blocked (by operator/customer or object) Application: Repeat job after a short pause. Measure: If error remains, notify Service.

28008052 PPD_SWITCH_UNIT_WRN Reason: Contact bar without function Measure: DO NOT CLOSE DOOR ! Serious jamming possible if closed ! Check contact bar. Inform Customer Service.

Page 682: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Panel Protection Door (PPD)

674 June 2004

28008053 PPD_LIGHT_BARRIER_WRN Reason: Light barrier is dirty or faulty. Measure: Have the hardware checked by Service.

28008054 PPD_HEAVY_MOVEABLE Reason: Door is difficult to operate Measure: Open the door and check the mechanics. Inform Customer Service.

28008055 PPD_FRM_NOT_LOAD_WRN Reason: Firmware not loaded or started. Application: If the warning occurs at OPEN, load the firmware with the CscPdpInit() function. Measure: Inform customer Service. Replace the hardware.

Page 683: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004 675

Numeric list of all messages StCode StWarn Define Device Page

20000001 DPS_WARN_LED DPS 615 20000001 LDND9G_WARN_FILE_CTR LDND9G 300 20000001 PRT_PAPER_RETRACTED ND97 268 20000002 DPS_WARN_NO_FIRMWARE DPS 616 20000002 LDND9G_WARN_FILE_NR LDND9G 300 20000002 PRT_WARN_NO_FIRMWARE_FILE ND99 279 20000003 DPS_WARN_FRM_FILE_ACCESS_ERROR DPS 616 20000003 PRT_WARN_NO_ACTUAL_FIRMWARE ND99 279 20000004 DPS_WARN_FRM_FILE_DATA_ERROR DPS 616 20000004 PRT_WARN_NO_FIRMWARE_LOADED ND99 279 20000005 PRT_WARN_WRONG_FIRMWARE_LOADED ND99 279 20000020 PRT_WEEKEND_LIMIT_OK_EVENT ND97 268 20000021 PRT_WEEKEND_LIMIT_EVENT ND97 268 20000022 PRT_PAPER_END_1_EVENT ND97 269 20000023 PRT_PAPER_END_2_EVENT ND97 269 20000024 PRT_PAPER_END_EVENT ND97 269 20001000 CNG_EXT_2X0_CONTEXT_ERROR CNG_EXT 495 20001001 CNG_EXT_2X0_SW_DEFECT CNG-EXT 495 20001001 CSC_FUNCTION_NOT_IMPLEMENTED Global 9 20001003 CSC_INVALID_SPEC Global 9 20001004 CSC_INVALID_INLEN Global 9 20001005 CSC_INVALID_OUTLEN Global 9 20001006 CSC_INVALID_LOGICAL_ID Global 10 20001007 CSC_INVALID_PID Global 10 20001009 CSC_DEVICE_ALREADY_OPENED Global 10 2000100D CSC_CSCINI_DLL_NOT_FOUND Global 10 2000100E CSC_CSCINI_DLL_OPEN_FAILED Global 10 2000100F CSC_DHL_NOT_INITIALIZED Global 11 20001010 CNG_EXT_2X0_CONTR_DEFECT CNG_EXT 495 20001011 CNG_EXT_2X0_NO_FIRMWARE CNG_EXT 495 20001012 CNG_EXT_2X0_SAFETY_CIRC_OPEN CNG_EXT 495 20001013 CNG_EXT_2X0_DLOC_YES CNG_EXT 496 20001014 CNG_EXT_2X0_CONFIG_NO_CAS CNG_EXT 496 20001014 CSC_REL_NOT_AVAIL Global 11 20001015 CSC_INVALID_COMMAND Global 11 20001017 CSC_TOO_MANY_USERS Global 11 20001018 CNG_EXT_2X0_JAM_DISPENSE CNG_EXT 496 20001018 CSC_CSCEDS_DLL_NOT_FOUND Global 11 20001019 CNG_EXT_2X0_JAM_OUTPUT_TRANS CNG_EXT 496

Page 684: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

676 June 2004

StCode StWarn Define Device Page

20001019 CSC_CSCEDS_DLL_OPEN_FAILED Global 11 2000101A CSC_CSCEDM_DLL_NOT_FOUND Global 12 2000101B CSC_CSCEDM_DLL_OPEN_FAILED Global 12 2000101D CSC_CSCCOMM_DLL_NOT_FOUND Global 12 2000101E CSC_CSCCOMM_DLL_OPEN_FAILED Global 12 20001020 CNG_EXT_2X0_SINGLE_REJ_DEFECT CNG_EXT 496 20001021 CNG_EXT_2X0_MS_DEFECT CNG_EXT 497 20001021 CSC_INI_WRONG_INTERFACE Global 12 20001022 CNG_EXT_2X0_LBAMP_DEFECT CNG_EXT 497 20001022 CSC_CSCSEL_DLL_NOT_FOUND Global 12 20001023 CNG_EXT_2X0_RESET_RW_DEFECT CNG_EXT 497 20001023 CSC_CSCSEL_DLL_OPEN_FAILED Global 13 20001024 CNG_EXT_2X0_RESET_RR_DEFECT CNG_EXT 497 20001025 CNG_EXT_2X0_VMOTOR_DEFECT CNG_EXT 497 20001025 CSC_CSCRECO_DLL_NOT_FOUND Global 13 20001026 CNG_EXT_2X0_COL_TRAY_DEFECT CNG_EXT 497 20001026 CSC_CSCRECO_DLL_OPEN_FAILED Global 13 20001027 CSC_DQF_DLL_NOT_FOUND Global 13 20001028 CNG_EXT_2X0_TRANS_SHUT_DEFECT CNG_EXT 498 20001028 CSC_DQF_DLL_OPEN_FAILED Global 13 20001029 CNG_EXT_2X0_OFFER_LB_L26_UE_COV CNG_EXT 498 20001029 CSC_CSC1394_DLL_NOT_FOUND Global 13 2000102A CSC_CSC1394_DLL_OPEN_FAILED Global 14 2000102B CSC_RECO_NOT_INSTALLED Global 14 20001031 CNG_EXT_2X0_CAS1_BUNDLE_REJECT CNG_EXT 498 20001032 CNG_EXT_2X0_CAS2_BUNDLE_REJECT CNG_EXT 498 20001033 CNG_EXT_2X0_CAS3_BUNDLE_REJECT CNG_EXT 498 20001034 CNG_EXT_2X0_CAS4_BUNDLE_REJECT CNG_EXT 498 20001035 CNG_EXT_2X0_CAS5_BUNDLE_REJECT CNG_EXT 499 20001036 CNG_EXT_2X0_CAS6_BUNDLE_REJECT CNG_EXT 499 20001041 CNG_EXT_2X0_CAS1_NO_SEPARATION CNG_EXT 499 20001042 CNG_EXT_2X0_CAS2_NO_SEPARATION CNG_EXT 499 20001043 CNG_EXT_2X0_CAS3_NO_SEPARATION CNG_EXT 499 20001044 CNG_EXT_2X0_CAS4_NO_SEPARATION CNG_EXT 499 20001045 CNG_EXT_2X0_CAS5_NO_SEPARATION CNG_EXT 500 20001046 CNG_EXT_2X0_CAS6_NO_SEPARATION CNG_EXT 500 20001051 CNG_EXT_2X0_CAS1_MANY_BAD_NOTES CNG_EXT 500 20001052 CNG_EXT_2X0_CAS2_MANY_BAD_NOTES CNG_EXT 500 20001053 CNG_EXT_2X0_CAS3_MANY_BAD_NOTES CNG_EXT 500 20001054 CNG_EXT_2X0_CAS4_MANY_BAD_NOTES CNG_EXT 500 20001055 CNG_EXT_2X0_CAS5_MANY_BAD_NOTES CNG_EXT 501 20001056 CNG_EXT_2X0_CAS6_MANY_BAD_NOTES CNG_EXT 501 20001061 CNG_EXT_2X0_CAS1_EEPROM_ERR CNG_EXT 501 20001062 CNG_EXT_2X0_CAS2_EEPROM_ERR CNG_EXT 501 20001063 CNG_EXT_2X0_CAS3_EEPROM_ERR CNG_EXT 501 20001064 CNG_EXT_2X0_CAS4_EEPROM_ERR CNG_EXT 501 20001065 CNG_EXT_2X0_CAS5_EEPROM_ERR CNG_EXT 502 20001066 CNG_EXT_2X0_CAS6_EEPROM_ERR CNG_EXT 502

Page 685: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 677

StCode StWarn Define Device Page

20001070 CNG_EXT_2X0_CONTAM_MS CNG_EXT 502 20001071 CNG_EXT_2X0_DEDUC_FLAG_LAM1 CNG_EXT 502 20001072 CNG_EXT_2X0_DEDUC_FLAG_LAM2 CNG_EXT 502 20001073 CNG_EXT_2X0_DEDUC_FLAG_LAM3 CNG_EXT 502 20001074 CNG_EXT_2X0_DEDUC_FLAG_LAM4 CNG_EXT 503 20001075 CNG_EXT_2X0_DEDUC_FLAG_LAM5 CNG_EXT 503 20001076 CNG_EXT_2X0_DEDUC_FLAG_LAM6 CNG_EXT 503 20001081 CNG_EXT_2X0_EMPTY_FLAG_KL1 CNG_EXT 503 20001082 CNG_EXT_2X0_EMPTY_FLAG_KL2 CNG_EXT 503 20001083 CNG_EXT_2X0_EMPTY_FLAG_KL3 CNG_EXT 503 20001084 CNG_EXT_2X0_EMPTY_FLAG_KL4 CNG_EXT 504 20001085 CNG_EXT_2X0_EMPTY_FLAG_KL5 CNG_EXT 504 20001086 CNG_EXT_2X0_EMPTY_FLAG_KL6 CNG_EXT 504 20001090 CNG_EXT_2X0_CONTAM_LB1 CNG_EXT 504 20001091 CNG_EXT_2X0_CONTAM_LB18 CNG_EXT 504 20001093 CNG_EXT_2X0_CONTAM_LB21 CNG_EXT 504 20001098 CNG_EXT_2X0_CONTAM_LB27 CNG_EXT 505 20001099 CNG_EXT_2X0_CONTAM_LB28 CNG_EXT 505 20001420 CSC_INVALID_HANDLE Global 14 20001421 CSC_INVALID_DEVICE Global 14 20001422 CSC_INVALID_PINDATA Global 14 20001423 CSC_INVALID_POUTDATA Global 14 20001424 CSC_DEVICE_LOCKED Global 15 20001425 CSC_DEVICE_NOT_LOCKED Global 15 20001426 CSC_INVALID_UNLOCK Global 15 20001427 CSC_ACCESS_TIMEOUT Global 15 20001800 CNG_EXT_CMD_CONTEXT_ERROR CNG_EXT 505 20001801 CNG_EXT_CMD_SW_DEFECT CNG_EXT 505 20001805 CNG_EXT_CMD_CHIPCONT_COMM_ERR CNG_EXT 505 20001806 CNG_EXT_CMD_CHIPCARD_COMM_ERR CNG_EXT 505 20001807 CNG_EXT_CMD_HW_NOT_CONFIRMED CNG_EXT 506 20001808 CNG_EXT_CMD_IDENT_PROM_ERROR CNG_EXT 506 20001809 CNG_EXT_CMD_SERVICE_SWITCH_OPEN CNG_EXT 506 20001810 CNG_EXT_CMD_CONTR_DEFECT CNG_EXT 506 20001811 CNG_EXT_CMD_NO_FIRMWARE CNG_EXT 506 20001812 CNG_EXT_CMD_SAFETY_CIRC_OPEN CNG_EXT 506 20001813 CNG_EXT_CMD_DLOC_YES CNG_EXT 507 20001814 CNG_EXT_CMD_CONFIG_NO_CAS CNG_EXT 507 20001817 CNG_EXT_CMD_OUTPUT_TRANS_DEFECT CNG_EXT 507 20001818 CNG_EXT_CMD_JAM_DISPENSE CNG_EXT 507 20001819 CNG_EXT_CMD_NOTE_TRANS_BLOCKED CNG_EXT 507 20001820 CNG_EXT_CMD_SINGLE_REJ_DEFECT CNG_EXT 508 20001821 CNG_EXT_CMD_MS_DEFECT CNG_EXT 508 20001822 CNG_EXT_CMD_LBAMP_DEFECT CNG_EXT 508 20001823 CNG_EXT_CMD_TURNTABLE_DEFECT CNG_EXT 508 20001824 CNG_EXT_CMD_RESET_RR_DEFECT CNG_EXT 508 20001825 CNG_EXT_CMD_VMOTOR_DEFECT CNG_EXT 508 20001826 CNG_EXT_CMD_STACKER_DEFECT CNG_EXT 509

Page 686: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

678 June 2004

StCode StWarn Define Device Page

20001828 CNG_EXT_CMD_TRANS_SHUT_DEFECT CNG_EXT 509 20001829 CNG_EXT_CMD_PS_OFFER_COV CNG_EXT 509 20001831 CNG_EXT_CMD_CAS1_MANY_REJECTS CNG_EXT 509 20001832 CNG_EXT_CMD_CAS2_MANY_REJECTS CNG_EXT 509 20001833 CNG_EXT_CMD_CAS3_MANY_REJECTS CNG_EXT 509 20001834 CNG_EXT_CMD_CAS4_MANY_REJECTS CNG_EXT 510 20001835 CNG_EXT_CMD_CAS5_MANY_REJECTS CNG_EXT 510 20001836 CNG_EXT_CMD_CAS6_MANY_REJECTS CNG_EXT 510 20001841 CNG_EXT_CMD_CAS1_NO_SEPARATION CNG_EXT 510 20001842 CNG_EXT_CMD_CAS2_NO_SEPARATION CNG_EXT 510 20001843 CNG_EXT_CMD_CAS3_NO_SEPARATION CNG_EXT 510 20001844 CNG_EXT_CMD_CAS4_NO_SEPARATION CNG_EXT 511 20001845 CNG_EXT_CMD_CAS5_NO_SEPARATION CNG_EXT 511 20001846 CNG_EXT_CMD_CAS6_NO_SEPARATION CNG_EXT 511 20001851 CNG_EXT_CMD_CAS1_MANY_BAD_NOTES CNG_EXT 511 20001852 CNG_EXT_CMD_CAS2_MANY_BAD_NOTES CNG_EXT 511 20001853 CNG_EXT_CMD_CAS3_MANY_BAD_NOTES CNG_EXT 511 20001854 CNG_EXT_CMD_CAS4_MANY_BAD_NOTES CNG_EXT 512 20001855 CNG_EXT_CMD_CAS5_MANY_BAD_NOTES CNG_EXT 512 20001856 CNG_EXT_CMD_CAS6_MANY_BAD_NOTES CNG_EXT 512 20001861 CNG_EXT_CMD_CAS1_EEPROM_ERR CNG_EXT 512 20001862 CNG_EXT_CMD_CAS2_EEPROM_ERR CNG_EXT 512 20001863 CNG_EXT_CMD_CAS3_EEPROM_ERR CNG_EXT 512 20001864 CNG_EXT_CMD_CAS4_EEPROM_ERR CNG_EXT 513 20001865 CNG_EXT_CMD_CAS5_EEPROM_ERR CNG_EXT 513 20001866 CNG_EXT_CMD_CAS6_EEPROM_ERR CNG_EXT 513 20001870 CNG_EXT_CMD_MS_defect CNG_EXT 513 20001871 CNG_EXT_CMD_DEDUC_FLAG_LAM1 CNG_EXT 513 20001872 CNG_EXT_CMD_DEDUC_FLAG_LAM2 CNG_EXT 513 20001873 CNG_EXT_CMD_DEDUC_FLAG_LAM3 CNG_EXT 514 20001874 CNG_EXT_CMD_DEDUC_FLAG_LAM4 CNG_EXT 514 20001875 CNG_EXT_CMD_DEDUC_FLAG_LAM5 CNG_EXT 514 20001876 CNG_EXT_CMD_DEDUC_FLAG_LAM6 CNG_EXT 514 20001881 CNG_EXT_CMD_EMPTY_FLAG_KL1 CNG_EXT 514 20001882 CNG_EXT_CMD_EMPTY_FLAG_KL2 CNG_EXT 514 20001883 CNG_EXT_CMD_EMPTY_FLAG_KL3 CNG_EXT 515 20001884 CNG_EXT_CMD_EMPTY_FLAG_KL4 CNG_EXT 515 20001885 CNG_EXT_CMD_EMPTY_FLAG_KL5 CNG_EXT 515 20001886 CNG_EXT_CMD_EMPTY_FLAG_KL6 CNG_EXT 515 20001890 CNG_EXT_CMD_CONTAM_LB1 CNG_EXT 515 20001891 CNG_EXT_CMD_CONTAM_LB18 CNG_EXT 515 20001893 CNG_EXT_CMD_CONTAM_LB2 CNG_EXT 516 20001895 CNG_EXT_CMD_CONTAM_LB26_LB27 CNG_EXT 516 2000189A CNG_EXT_CMD_CONTAM_LB28_LB29 CNG_EXT 516 2000189D CNG_EXT_CMD_CONTAM_LB2_REJECT_BOX CNG_EXT 516 2000189E CNG_EXT_CMD_CONTAM_LB3_REJECT_BOX CNG_EXT 516 20002001 INI_FUNCTION_NOT_IMPLEMENTED INI 16 20002003 INI_INVALID_SPEC INI 16

Page 687: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 679

StCode StWarn Define Device Page

20002004 INI_INVALID_INLEN INI 16 20002005 INI_INVALID_OUTLEN INI 16 20002422 INI_INVALID_PINDATA INI 17 20002423 INI_INVALID_POUTDATA INI 17 20002903 INI_ID_ITEM_NOT_FOUND INI 17 20002904 INI_KEYWORD_NOT_FOUND INI 17 20002905 INI_INVALID_BAUDRATE INI 18 20002906 INI_INVALID_DATABITS INI 18 20002907 INI_INVALID_STOPBITS INI 18 20002908 INI_INVALID_PARITY INI 18 20002909 INI_INVALID_PROTOCOL INI 18 2000290A INI_INVALID_VALUE INI 18 2000290B INI_INVALID_ROOT INI 19 2000290C INI_CONFIG_ERROR INI 19 20003000 CNG_EXT_CRS_CONTEXT_ERROR CNG_EXT 516 20003000 CSC_CANCELED Global 15 20003010 CNG_EXT_CRS_SW_DEFEKT CNG_EXT 517 20003016 CNG_EXT_CRS_FRM_DEFEKT CNG_EXT 517 20003020 CNG_EXT_CRS_COMM_INT_ERROR CNG_EXT 517 20003025 CNG_EXT_CRS_SUBCONTR_NO_FRM CNG_EXT 517 20003100 CNG_EXT_CRS_SUBCONTR_DEFEKT CNG_EXT 517 20003101 CNG_EXT_CRS_SUBCONTR_NO_BOOTER CNG_EXT 517 20003105 CNG_EXT_CRS_CONTR_DEFEKT CNG_EXT 518 20003106 CNG_EXT_CRS_CONTR_NO_BOOTER CNG_EXT 518 20003110 CNG_EXT_CRS_NO_SW CNG_EXT 518 20003120 CNG_EXT_CRS_SAFE_SAFETYCIRC_OPEN CNG_EXT 518 20003125 CNG_EXT_COUNT_SAFETYCIRC_OPEN CNG_EXT 518 20003135 CNG_EXT_CRS_DLOC_YES CNG_EXT 519 20003136 CNG_EXT_CRS_ILOC_YES CNG_EXT 519 20003137 CNG_EXT_CRS_L3_BOX_FULL CNG_EXT 519 20003140 CNG_EXT_CRS_CONF_NO_CASHOUT_CAS CNG_EXT 519 20003145 CNG_EXT_CRS_CONF_NO_CASHIN_CASS CNG_EXT 519 20003146 CNG_EXT_CONF_AUTHENTICATOR_MISS CNG_EXT 520 20003170 CNG_EXT_JAM_CASHIN_TRANSPNT_CASS CNG_EXT 520 20003171 CNG_EXT_JAM_CASHIN_TRANSPNT_DRUM CNG_EXT 520 20003175 CNG_EXT_JAM_CASHIN_IN_OUT_TRAY CNG_EXT 520 20003176 CNG_EXT_JAM_CASHIN_TRAY_ESCROW CNG_EXT 520 20003178 CNG_EXT_JAM_CASHIN_ESCROW_OUT CNG_EXT 521 20003179 CNG_EXT_JAM_IN_ESCROW_TRANSPNT CNG_EXT 521 20003180 CNG_EXT_CASS_TRANSPORT CNG_EXT 521 20003181 CNG_EXT_JAM_OUT_DRUM_TRANSPNT CNG_EXT 521 20003182 CNG_EXT_JAM_OUT_TRANSPNT_REJCASS CNG_EXT 521 20003185 CNG_EXT_JAM_OUT_TRANSPNT_OUTTRAY CNG_EXT 522 20003186 CNG_EXT_JAM_REJ_OUTTRAY_TRANSPNT CNG_EXT 522 20003187 CNG_EXT_JAM_RET_OUTTRAY_TRANSPNT CNG_EXT 522 20003200 CNG_EXT_DEFLECTOR_DEF_INBOX_1 CNG_EXT 522 20003201 CNG_EXT_DEFLECTOR_DEF_INBOX_2 CNG_EXT 522 20003202 CNG_EXT_DEFLECTOR_DEF_INBOX_3 CNG_EXT 523

Page 688: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

680 June 2004

StCode StWarn Define Device Page

20003203 CNG_EXT_DEFLECTOR_DEF_INBOX_4 CNG_EXT 523 20003204 CNG_EXT_DEFLECTOR_DEF_INBOX_5 CNG_EXT 523 20003205 CNG_EXT_DEFLECTOR_DEF_TRANSPNT CNG_EXT 523 20003206 CNG_EXT_DEFLECTOR_DEF_SINGLE_REJ CNG_EXT 523 20003207 CNG_EXT_DEFLECTOR_DEFECT_ESCROW CNG_EXT 524 20003210 CNG_EXT_CRS_MS_DEFECT_CASHOUT CNG_EXT 524 20003211 CNG_EXT_CRS_LINE_X_ERROR_CONF CNG_EXT 524 20003212 CNG_EXT_CRS_CONTAM_LINE_X_SENS CNG_EXT 524 20003213 CNG_EXT_CRS_LINE_X_SENS_DEFECT CNG_EXT 524 20003214 CNG_EXT_CRS_TAPE_SENSOR_DEFECT CNG_EXT 525 20003215 CNG_EXT_CRS_MS_DEFECT_CASHIN CNG_EXT 525 20003216 CNG_EXT_AUTHENTICATOR_READER_DEF CNG_EXT 525 20003217 CNG_EXT_AUTHENTICATOR_COMM_DEF CNG_EXT 525 20003218 CNG_EXT_AUTHENTICATOR_NOTETIMING CNG_EXT 525 20003219 CNG_EXT_AUTHENTICATOR_RESPONSE CNG_EXT 526 20003220 CNG_EXT_CRS_LB_AMP_DEFECT CNG_EXT 526 20003230 CNG_EXT_CRS_DEFL_RETRACT_DEF CNG_EXT 526 20003231 CNG_EXT_CRS_DEFL_SELECTION_DEF CNG_EXT 526 20003232 CNG_EXT_CRS_DEFL_REJECT_DEF CNG_EXT 526 20003233 CNG_EXT_CRS_DEFL_RETRACT_DEF CNG_EXT 527 20003234 CNG_EXT_CRS_DEFL_SELECTION_DEF CNG_EXT 527 20003235 CNG_EXT_CRS_DEFL_SELECT_REJ_DEF CNG_EXT 527 20003250 CNG_EXT_CRS_TRANS_MOTOR_M1_DEF CNG_EXT 527 20003251 CNG_EXT_CRS_TRANS_MOTOR_M4_DEF CNG_EXT 527 20003255 CNG_EXT_CRS_TRANS_MOTOR_M2_DEF CNG_EXT 527 20003256 CNG_EXT_CRS_TRANS_MOTOR_M3_DEF CNG_EXT 528 20003285 CNG_EXT_SHUTTER_ERROR_OUT_TRAY CNG_EXT 528 20003286 CNG_EXT_SHUTTER_ERROR_IN_TRAY CNG_EXT 528 20003287 CNG_EXT_ROCKER_BLOCKED_OUT_TRAY CNG_EXT 528 20003295 CNG_EXT_MANIPULATION_OUT_TRAY CNG_EXT 528 20003296 CNG_EXT_MANIPULATION_IN_TRAY CNG_EXT 528 20003310 CNG_EXT_CASHOUT_CAS1_BUNDLE_REJ CNG_EXT 529 20003320 CNG_EXT_CASHOUT_CAS2_BUNDLE_REJ CNG_EXT 529 20003330 CNG_EXT_CASHOUT_CAS3_BUNDLE_REJ CNG_EXT 529 20003340 CNG_EXT_CASHOUT_CAS4_BUNDLE_REJ CNG_EXT 529 20003405 CNG_EXT_CASHIN_NO_SEPARATION CNG_EXT 529 20003406 CNG_EXT_CASHOUT_NO_SEPARATION CNG_EXT 529 20003407 CNG_EXT_CRS_DETECT_METAL_CASHIN CNG_EXT 530 20003408 CNG_EXT_CRS_DETECT_HIGH_CASHIN CNG_EXT 530 20003410 CNG_EXT_CRS_CAS1_NO_SEPARATION CNG_EXT 530 20003411 CNG_EXT_CRS_DRUM1_NO_SEPARATION CNG_EXT 530 20003420 CNG_EXT_CRS_CAS2_NO_SEPARATION CNG_EXT 530 20003421 CNG_EXT_CRS_DRUM2_NO_SEPARATION CNG_EXT 530 20003430 CNG_EXT_CRS_CAS3_NO_SEPARATION CNG_EXT 531 20003431 CNG_EXT_CRS_DRUM3_NO_SEPARATION CNG_EXT 531 20003440 CNG_EXT_CRS_CAS4_NO_SEPARATION CNG_EXT 531 20003441 CNG_EXT_CRS_DRUM4_NO_SEPARATION CNG_EXT 531 20003451 CNG_EXT_CRS_DRUM5_NO_SEPARATION CNG_EXT 531

Page 689: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 681

StCode StWarn Define Device Page

20003461 CNG_EXT_CRS_DRUM6_NO_SEPARATION CNG_EXT 531 20003510 CNG_EXT_CRS_CAS1_OUT_WIDTH_TOL CNG_EXT 532 20003520 CNG_EXT_CRS_CAS2_OUT_WIDTH_TOL CNG_EXT 532 20003530 CNG_EXT_CRS_CAS3_OUT_WIDTH_TOL CNG_EXT 532 20003540 CNG_EXT_CRS_CAS4_OUT_WIDTH_TOL CNG_EXT 532 20003605 CNG_EXT_ESCROW_DEFECT CNG_EXT 532 20003606 CNG_EXT_ESCROW_START_ERROR CNG_EXT 532 20003607 CNG_EXT_ESCROW_STEP_MOTOR CNG_EXT 533 20003608 CNG_EXT_ESCROW_TIMING CNG_EXT 533 20003610 CNG_EXT_CRS_CAS1_EEPROM_ERR CNG_EXT 533 20003611 CNG_EXT_CRS_DRUM1_DEFECT CNG_EXT 533 20003620 CNG_EXT_CRS_CAS2_EEPROM_ERR CNG_EXT 533 20003621 CNG_EXT_CRS_DRUM2_DEFECT CNG_EXT 533 20003630 CNG_EXT_CRS_CAS3_EEPROM_ERR CNG_EXT 534 20003631 CNG_EXT_CRS_DRUM3_DEFECT CNG_EXT 534 20003640 CNG_EXT_CRS_CAS4_EEPROM_ERR CNG_EXT 534 20003641 CNG_EXT_CRS_DRUM4_DEFECT CNG_EXT 534 20003651 CNG_EXT_CRS_DRUM5_DEFECT CNG_EXT 534 20003661 CNG_EXT_CRS_DRUM6_DEFECT CNG_EXT 534 20003700 CNG_EXT_CRS_CONTAM_MS_SAFE CNG_EXT 535 20003705 CNG_EXT_CRS_CONTAM_MS_COUNT CNG_EXT 535 20003710 CNG_EXT_CRS_DEDUC_FLAG_LAM1 CNG_EXT 535 20003720 CNG_EXT_CRS_DEDUC_FLAG_LAM2 CNG_EXT 535 20003730 CNG_EXT_CRS_DEDUC_FLAG_LAM3 CNG_EXT 535 20003740 CNG_EXT_CRS_DEDUC_FLAG_LAM4 CNG_EXT 535 20003810 CNG_EXT_CRS_EMPTY_FLAG_KL1 CNG_EXT 536 20003820 CNG_EXT_CRS_EMPTY_FLAG_KL2 CNG_EXT 536 20003830 CNG_EXT_CRS_EMPTY_FLAG_KL3 CNG_EXT 536 20003840 CNG_EXT_CRS_EMPTY_FLAG_KL4 CNG_EXT 536 20003901 CNG_EXT_CRS_CONTAM_LB1 CNG_EXT 536 20003902 CNG_EXT_CRS_CONTAM_LB2 CNG_EXT 536 20003903 CNG_EXT_CRS_CONTAM_LB3 CNG_EXT 537 20003904 CNG_EXT_CRS_CONTAM_LB4 CNG_EXT 537 20003905 CNG_EXT_CRS_CONTAM_LB5 CNG_EXT 537 20003906 CNG_EXT_CRS_CONTAM_LB6 CNG_EXT 537 20003907 CNG_EXT_CRS_CONTAM_LB7 CNG_EXT 537 20003908 CNG_EXT_CRS_CONTAM_LB8 CNG_EXT 537 20003909 CNG_EXT_CRS_CONTAM_LB9 CNG_EXT 538 20003910 CNG_EXT_CRS_CONTAM_LB10 CNG_EXT 538 20003911 CNG_EXT_CRS_CONTAM_LB11 CNG_EXT 538 20003912 CNG_EXT_CRS_CONTAM_LB12 CNG_EXT 538 20003913 CNG_EXT_CRS_CONTAM_LB13 CNG_EXT 538 20003914 CNG_EXT_CRS_CONTAM_LB14 CNG_EXT 538 20003915 CNG_EXT_CRS_CONTAM_LB15 CNG_EXT 539 20003916 CNG_EXT_CRS_CONTAM_LB16 CNG_EXT 539 20003917 CNG_EXT_CRS_CONTAM_LB17 CNG_EXT 539 20003918 CNG_EXT_CRS_CONTAM_LB18 CNG_EXT 539 20003919 CNG_EXT_CRS_CONTAM_LB19 CNG_EXT 539

Page 690: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

682 June 2004

StCode StWarn Define Device Page

20003920 CNG_EXT_CRS_CONTAM_LB20 CNG_EXT 539 20003921 CNG_EXT_CRS_CONTAM_LB21 CNG_EXT 540 20003922 CNG_EXT_CRS_CONTAM_LB22 CNG_EXT 540 20003923 CNG_EXT_CRS_CONTAM_LB23 CNG_EXT 540 20003924 CNG_EXT_CRS_CONTAM_LB24 CNG_EXT 540 20003925 CNG_EXT_CRS_CONTAM_LB25 CNG_EXT 540 20003926 CNG_EXT_CRS_CONTAM_LB26 CNG_EXT 540 20003931 CNG_EXT_CRS_CONTAM_LB_DRUM1 CNG_EXT 541 20003932 CNG_EXT_CRS_CONTAM_LB_DRUM2 CNG_EXT 541 20003933 CNG_EXT_CRS_CONTAM_LB_DRUM3 CNG_EXT 541 20003934 CNG_EXT_CRS_CONTAM_LB_DRUM4 CNG_EXT 541 20003935 CNG_EXT_CRS_CONTAM_LB_DRUM5 CNG_EXT 541 20003936 CNG_EXT_CRS_CONTAM_LB_DRUM6 CNG_EXT 541 20003941 CNG_EXT_CRS_DRUM1_WRONG_POS CNG_EXT 542 20003942 CNG_EXT_CRS_DRUM2_WRONG_POS CNG_EXT 542 20003943 CNG_EXT_CRS_DRUM3_WRONG_POS CNG_EXT 542 20003944 CNG_EXT_CRS_DRUM4_WRONG_POS CNG_EXT 542 20003945 CNG_EXT_CRS_DRUM5_WRONG_POS CNG_EXT 542 20003946 CNG_EXT_CRS_DRUM6_WRONG_POS CNG_EXT 542 20003951 CNG_EXT_CRS_ERR_LOAD_FW_COMP_1 CNG_EXT 543 20003952 CNG_EXT_CRS_ERR_LOAD_FW_COMP_2 CNG_EXT 543 20003953 CNG_EXT_CRS_ERR_LOAD_FW_COMP_3 CNG_EXT 543 20003954 CNG_EXT_CRS_ERR_LOAD_FW_COMP_4 CNG_EXT 543 20003955 CNG_EXT_CRS_ERR_LOAD_FW_COMP_5 CNG_EXT 543 20003961 CNG_EXT_CRS_ERR_LOAD_FW_HSK_1 CNG_EXT 543 20003962 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_1 CNG_EXT 544 20003963 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_2 CNG_EXT 544 20003964 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_3 CNG_EXT 544 20003965 CNG_EXT_CRS_ERR_LOAD_FW_HSK_2_4 CNG_EXT 544 20003971 CNG_EXT_CRS_COMM_ERROR_HSK_1 CNG_EXT 544 20003972 CNG_EXT_CRS_COMM_ERROR_HSK_2_1 CNG_EXT 544 20003973 CNG_EXT_CRS_COMM_ERROR_HSK_2_2 CNG_EXT 545 20003974 CNG_EXT_CRS_COMM_ERROR_HSK_2_3 CNG_EXT 545 20003975 CNG_EXT_CRS_COMM_ERROR_HSK_2_4 CNG_EXT 545 20004000 CSC_TIMEOUT Global 16 20004001 CNG_EXT_SW_DEFEKT CNG-EXT 545 20004010 CNG_EXT_CONTR_DEFEKT CNG_EXT 545 20004011 CNG_EXT_NO_FIRMWARE CNG_EXT 546 20004012 CNG_EXT_SAFETY_CIRC_BREAK_OPEN CNG_EXT 546 20004013 CNG_EXT_DLOC_YES CNG_EXT 546 20004018 CNG_EXT_JAM_DISPENSE CNG_EXT 546 20004020 CNG_EXT_SINGLE_REJ_DEFECT CNG_EXT 546 20004021 CNG_EXT_MS_DEFECT CNG_EXT 547 20004022 CNG_EXT_LBAMP_DEFECT CNG_EXT 547 20004025 CNG_EXT_VMOTOR_DEFECT CNG_EXT 547 20004026 CNG_EXT_COL_TRAY_DEFECT CNG_EXT 547 20004100 CNG_EXT_CAS_NOT_READY CNG_EXT 547 20004114 CNG_EXT_CONFIG_NO_REJECT CNG_EXT 548

Page 691: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 683

StCode StWarn Define Device Page

20004119 CNG_EXT_JAM_REJECT_STACK_REJ CNG_EXT 548 20004123 CNG_EXT_RESET_RW_DEFECT CNG_EXT 548 20004124 CNG_EXT_RESET_RR_DEFECT CNG_EXT 548 20004128 CNG_EXT_TRANS_SHUT_ERR_OPEN CNG_EXT 548 20004129 CNG_EXT_OFFER_LB_L26_UE_COV CNG_EXT 549 20004200 CNG_EXT_SHUTTER_BLOCKED CNG_EXT 549 20004214 CNG_EXT_CONFIG_REJECT_NOT_READY CNG_EXT 549 20004219 CNG_EXT_JAM_REJECT_OVER_STACKER CNG_EXT 549 20004223 CNG_EXT_RETRACT_RW_DEFECT CNG_EXT 549 20004224 CNG_EXT_RETRACT_RR_DEFECT CNG_EXT 550 20004228 CNG_EXT_OFFER_SHUT_ERR_UNDEF CNG_EXT 550 20004229 CNG_EXT_WITHDRAWN_LB_L26_UE_COV CNG_EXT 550 20004300 CNG_EXT_SHUTTER_OPEN CNG_EXT 550 20004314 CNG_EXT_CONFIG_NO_CAS CNG_EXT 550 20004319 CNG_EXT_JAM_TRANS_STACKER_OVER CNG_EXT 551 20004328 CNG_EXT_WITHDRAWN_SHUT_ERR_CLOS CNG_EXT 551 20004329 CNG_EXT_RETRACT_LB_L26_UE_COV CNG_EXT 551 20004400 CNG_EXT_SHUTTER_UNDEFINED CNG_EXT 551 20004414 CNG_EXT_CONFIG_CAS_NOT_READY CNG_EXT 551 20004419 CNG_EXT_JAM_TRANS_OVER_SHUT CNG_EXT 552 20004428 CNG_EXT_RETRACT_SHUT_ERR_UNDEF CNG_EXT 552 20004429 CNG_EXT_TRANS_LB_L26_UE_COVERED CNG_EXT 552 20004500 CNG_EXT_L26_UE_COVERED CNG_EXT 552 20004519 CNG_EXT_JAM_RETR_SHUT_OVER CNG_EXT 552 20004529 CNG_EXT_OFFER_SHUT_BLOCKED CNG_EXT 553 20004600 CNG_EXT_LB_COVERED CNG_EXT 553 20004619 CNG_EXT_JAM_RETR_HORIZ_STACKER CNG_EXT 553 20004629 CNG_EXT_WITHDRAWN_SHUT_BLOCKED CNG_EXT 553 20004700 CNG_EXT_DEVICE_LOCK CNG_EXT 553 20004719 CNG_EXT_JAM_RETR_STACKER_REJ CNG_EXT 554 20004729 CNG_EXT_RETR_SHUT_BLOCKED CNG_EXT 554 20004800 CNG_EXT_SINGLE_REJ_ERROR CNG_EXT 554 20004800 PIN_FATAL_TIMEOUT PIN 127 20004829 CNG_EXT_TRANS_SHUT_BLOCKED CNG_EXT 554 20004900 CNG_EXT_SELF_TEST_AKTIVATE CNG_EXT 554 20004919 CNG_EXT_OFFER_LB_UE_COV CNG_EXT 555 20004A00 CNG_EXT_FEED_JAM CNG_EXT 555 20004A19 CNG_EXT_WITHDRAWN_LB_UE_COV CNG_EXT 555 20004B00 CNG_EXT_CAS_MISSING CNG_EXT 555 20004B19 CNG_EXT_RETR_LB_UE_COV CNG_EXT 555 20004C19 CNG_EXT_MOTOR_DEFECT CNG_EXT 556 20004D00 CNG_EXT_CAS_EMPTY CNG_EXT 556 20004E00 CNG_EXT_CAS_DEFECT CNG_EXT 556 20004F00 CNG_EXT_CAS_DISP_EMPTY CNG_EXT 556 20007FFB IDU_WARN_INVALID_CHIPMODE IDU 105 20007FFC IDU_WARN_MEMORY_RESET IDU 105 20007FFD IDU_WARN_TRANSACTION IDU 105 20007FFE IDU_WARN_LED IDU 105

Page 692: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

684 June 2004

StCode StWarn Define Device Page

20007FFE SEL_WARN_RESYNC SEL 125 20007FFF PIN_WARN_GHOSTCODE PIN 131 20008000 BCD_INVALID_RESPONSE BCD 597 20008000 CBKM_THUMBPRINT_ERROR CBKM 173 20008000 CCDM_INVALID_PARA CCDM 617 20008000 CCM_CONT_UNDEF_ERROR CCM 113 20008000 CDM_INVALID_CAS_SLOT CDM 413 20008000 CM3K_INVALID_PARA CM3K 339 20008000 LDE_MEMORY_ALLOC_ERROR LDE 193 20008000 LDND9G_INVALID_FILE LDND9G 299 20008000 LDR_FRM_ERROR LDR 581 20008000 LDR3_LOAD_SEM_TIMEOUT LDR3 273 20008000 OPT_MEMORY_ALLOC_ERROR OPT 185 20008000 P36_THREAD_START_ERROR P36 583 20008000 PPD_UNDEF_FRM_ERROR PPD 667 20008000 PRTX_SYSTEM_ERROR PRTX 291 20008000 PSM_THREAD_START_ERROR PSM 87 20008000 RCH_INVALID_ACTIVE_PARA RCH 21 20008000 RECO_NO_DONGLE RECO 361 20008000 RSA_MEMORY_ALLOC_ERROR RSA 167 20008000 S500_INVALID_PARA S500 329 20008000 SCAN_DRIVER_NOT_FOUND SCAN 237 20008000 SCO_CHIP_CONTROLLER_ERROR SCO 163 20008000 SEL_INVALID_DATA SEL 115 20008000 SEP_MEMORY_ALLOC_ERROR SEP 175 20008000 TSC_INVALID_PARA TSC 353 20008000 USB_FALSE_DESCRIPTOR_TYPE USB 63 20008000 ZKA_MEMORY_ALLOC_ERROR ZKA 205 20008001 BCD_INVALID_COMMAND BCD 597 20008001 CBKM_INVALID_RAND CBKM 173 20008001 CCDM_NO_DOCUMENT CCDM 617 20008001 CDM_ERROR_SELFTEST CDM 413 20008001 CM3K_NO_DOCUMENT CM3K 339 20008001 COUT_NO_COINS COUT 587 20008001 EDS_ERROR_NO_TK EDS 143 20008001 LDE_FRM_UNDEF_ERROR LDE 193 20008001 LDND9G_FILE_ACCESS_ERROR LDND9G 299 20008001 LDR_INVALID_FRM_DATA LDR 581 20008001 LDR3_INI_FILE_OPEN_FAILED LDR3 273 20008001 OPT_FRM_UNDEF_ERROR OPT 185 20008001 P36_THREAD_STOP_ERROR P36 583 20008001 PIN_ERROR_INIT_DATA PIN 127 20008001 PRT_NO_DLL_FILE PRT 221 20008001 PRTX_SERVER_ERROR PRTX 291 20008001 PSM_CANT_CREATE_MUTEX PSM 87 20008001 RCH_INVALID_LANGUAGE RCH 21 20008001 RECO_SET_ERROR_FKT RECO 361 20008001 S500_NO_DOCUMENT S500 329

Page 693: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 685

StCode StWarn Define Device Page

20008001 SCAN_DRIVER_OPEN_FAILED SCAN 237 20008001 SCO_OFFLINE_CHIP_MISSING SCO 163 20008001 SEP_FRM_UNDEF_ERROR SEP 175 20008001 TSC_NO_DOCUMENT TSC 353 20008001 USB_DEVICE_NOT_FOUND USB 63 20008001 ZKA_FRM_UNDEF_ERROR ZKA 205 20008002 CBKM_INVALID_SIG CBKM 173 20008002 CCDM_MICR_NOT_SELECTED CCDM 617 20008002 CDM_INVALID_ERROR_DATA CDM 413 20008002 CM3K_MICR_NOT_SELECTED CM3K 339 20008002 COUT_OUT_OF_ORDER COUT 587 20008002 EDS_ERROR_TK_PARITY EDS 143 20008002 LDND9G_INVALID_MODID LDND9G 299 20008002 LDR_INVALID_FRM_FILE_MOD LDR 581 20008002 LDR3_INI_FILE_READ_ERROR LDR3 273 20008002 P36_INVALID_P36SIGPARA P36 583 20008002 PIN_ERROR_NO_FUNC PIN 127 20008002 PRT_PRT_FILE_NOT_FOUND PRT 221 20008002 PRTX_NOT_CONNECTED PRTX 291 20008002 PSM_SEL_ERROR PSM 87 20008002 RCH_INVALID_PTXTBUF RCH 21 20008002 RECO_NO_RECOSTAR_MODUL RECO 361 20008002 RSA_BUFFER_TO_SMALL RSA 167 20008002 S500_MICR_NOT_SELECTED S500 329 20008002 SCO_OFFLINE_CHIP_APL_ERROR SCO 163 20008002 USB_INSUFFICIENT_MEMORY USB 63 20008002 ZKA_GA_RESULT ZKA 205 20008003 BCD_INVALID_BKNOTES_FILE BCD 598 20008003 CBKM_INVALID_KEYID CBKM 173 20008003 CCDM_INVALID_WINDOWS_VERSION CCDM 618 20008003 CDM_INVALID_WARNING_DATA CDM 413 20008003 COUT_POWER_ERR_RECOVER COUT 587 20008003 EDS_ERROR_NO_CBC_KEY EDS 143 20008003 LDE_WRONG_CTL LDE 193 20008003 LDND9G_FRM_LOADER_NOT_READY LDND9G 299 20008003 LDR_FRM_FILE_NOT_FOUND LDR 581 20008003 LDR3_INVALID_FILE LDR3 273 20008003 OPT_NO_OZR OPT 185 20008003 PIN_ERROR_UNKNOWN PIN 128 20008003 PRT_PRT_FILE_OPEN_FAILED PRT 221 20008003 PRTX_ACCESS_TIMEOUT PRTX 291 20008003 RECO_NO_CTRL_FILE RECO 362 20008003 RSA_UNDEF_ERROR RSA 167 20008003 SCO_ONLINE_CHIP_APL_ERROR SCO 163 20008003 USB_ENDPOINT_NOT_FOUND USB 63 20008003 ZKA_UNKNOWN_TAG ZKA 205 20008004 BCD_INVALID_BKN_FILE_FORMAT BCD 598 20008004 CBKM_INVALID_KEYNO CBKM 174

Page 694: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

686 June 2004

StCode StWarn Define Device Page

20008004 CCDM_PAPER_TRAY CCDM 618 20008004 CDM_CSCEDS_DLL_NOT_FOUND CDM 414 20008004 COUT_POWER_ERR COUT 588 20008004 EDS_ERROR_CBC_PARITY EDS 144 20008004 LDE_NO_FRMFILE_REL LDE 193 20008004 LDND9G_INVALID_LOADED_FILE LDND9G 300 20008004 LDR_FRM_FILE_OPEN_FAILED LDR 582 20008004 LDR3_FILE_ACCESS_ERROR LDR3 274 20008004 OPT_NO_OZP OPT 185 20008004 PIN_ERROR_PINPAD_TYP PIN 128 20008004 PRT_BAD_PRT_FILE PRT 221 20008004 PRTX_GET_NOTIFICATION_CANCELLED PRTX 292 20008004 RCH_INVALID_TXTBUF_LEN RCH 21 20008004 RECO_NOT_ONE_CTRL_FILE RECO 362 20008004 RSA_EXPONENT_LEN RSA 167 20008004 SCO_NO_MSG_PARAMETER SCO 164 20008004 TSC_INVALID_RXDATA TSC 353 20008004 USB_CREATE_DEVICE_LIST_FAILED USB 64 20008004 ZKA_CASH_ID ZKA 206 20008005 BCD_BKNFILE_SECTION_NOT_FOUND BCD 598 20008005 CBKM_INVALID_KEYVER CBKM 174 20008005 CCDM_INVALID_RESPONSE CCDM 618 20008005 CDM_CSCEDS_DLL_OPEN_FAILED CDM 414 20008005 COUT_RESET_RECOVER COUT 588 20008005 EDS_ERROR_NO_IV EDS 144 20008005 LDE_SEQUENCE_CANT_OPEN LDE 194 20008005 LDND9G_SERVER_ERROR LDND9G 300 20008005 LDR3_INVALID_MODID LDR3 274 20008005 OPT_KERNEL_WRONG_STATE OPT 186 20008005 PIN_ERROR_PINPAD_LINE PIN 128 20008005 PRT_NO_MACROEND PRT 222 20008005 PRTX_SERVICE_ERROR PRTX 292 20008005 RCH_INVALID_PCSCDHLPARA RCH 22 20008005 RECO_CTRL_FILE_OPEN_ERROR RECO 362 20008005 RSA_MODULUS_LEN RSA 168 20008005 SCO_WRONG_MSG_PARAMETER SCO 164 20008005 TSC_READ_TIMEOUT TSC 354 20008005 ZKA_NO_FRMFILE_REL ZKA 206 20008006 BCD_BKNFILE_DENOMIN_NOT_FOUND BCD 598 20008006 CBKM_KEY_NOT_TRUSTED CBKM 174 20008006 CCDM_ERROR_OPEN_RAW_FILE CCDM 618 20008006 CDM_INVALID_CRC CDM 414 20008006 CM3K_ERROR_OPEN_RAW_FILE CM3K 339 20008006 COUT_RESET COUT 588 20008006 LDE_SEQUENCE_NO_KEYFILE LDE 194 20008006 LDR3_FRM_LOADER_NOT_READY LDR3 274 20008006 OPT_LOAD_AP_WRONG_STATE OPT 186 20008006 PIN_ERROR_LOAD_TK PIN 128

Page 695: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 687

StCode StWarn Define Device Page

20008006 PRT_FMT_FILE_NOT_FOUND PRT 222 20008006 RECO_CTRL_FILE_READ_ERROR RECO 362 20008006 RSA_NO_KEY_INFO RSA 168 20008006 SCO_CONT_UNDEF_ERROR SCO 164 20008006 TSC_ERROR_OPEN_RAW_FILE TSC 354 20008006 ZKA_UNKNOWN_BRK ZKA 206 20008007 BCD_SHUTTER_ERROR BCD 599 20008007 CBKM_INVALID_SCDNO CBKM 174 20008007 CCDM_ERROR_WRITE_RAW_FILE CCDM 618 20008007 CDM_INVALID_KEYWORD_LEN CDM 414 20008007 CM3K_ERROR_WRITE_FILE CM3K 340 20008007 COUT_HOPPER_NOT_INSTALLED COUT 588 20008007 EDS_ERROR_NO_ECB_KEY EDS 144 20008007 LDE_RKL_TOKENFILE_OPEN_ERR LDE 194 20008007 LDR3_INVALID_LOADED_FILE LDR3 274 20008007 PIN_ERROR_LOAD_LK PIN 128 20008007 PRT_FMT_FILE_OPEN_FAILED PRT 222 20008007 RCH_INVALID_STCLASS RCH 22 20008007 RECO_INIT_TIFF_FKT_ERROR RECO 363 20008007 RSA_WRONG_KEY_INFO RSA 168 20008007 TSC_ERROR_WRITE_RAW_FILE TSC 354 20008008 BCD_BAD_UVLAMP BCD 599 20008008 CCDM_ERROR_SHUTTER_OPEN CCDM 619 20008008 CM3K_ERROR_SHUTTER_OPEN CM3K 340 20008008 COUT_HOPPER_BLOCKED COUT 588 20008008 EDS_ERROR_ECB_PARITY EDS 144 20008008 LDE_RKL_TOKENFILE_UID_ERR LDE 194 20008008 PIN_ERROR_LOAD_IV PIN 128 20008008 PRT_BAD_FMT_FILE PRT 222 20008008 RCH_INVALID_FILE_ID RCH 22 20008008 RECO_OPEN_TIFF_FILE RECO 363 20008009 BCD_PROCESS_ERROR0 BCD 599 20008009 CCDM_ERROR_SHUTTER_CLOSE CCDM 619 20008009 CDM_INVALID_CAS_DATA_SEL CDM 414 20008009 CM3K_ERROR_SHUTTER_CLOSE CM3K 340 20008009 COUT_SENSOR_ERROR COUT 589 20008009 PIN_ERROR_NO_TK PIN 129 20008009 PRT_FALSE_STATUS_LEN ND71 245 20008009 PRT_FALSE_STATUS_LEN ND97 263 20008009 PRT_FALSE_STATUS_LEN PRT 222 20008009 RCH_INVALID_TREE RCH 22 20008009 RECO_MEMORY_TIFF_FILE RECO 363 2000800A BCD_PROCESS_ERROR1 BCD 599 2000800A CCDM_INVALID_CRC CCDM 619 2000800A COUT_HOPPER_NOT_CONNECTED COUT 589 2000800A EDS_ERROR_ZERO_BUFFER_LENGTH EDS 144 2000800A INVALID_KEY_FILE_LEN PIN 129 2000800A LDE_RKL_TOKENIMPORT_ERR LDE 194

Page 696: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

688 June 2004

StCode StWarn Define Device Page

2000800A PRT_BUFFER_TO_SHORT PRT 223 2000800A RCH_UNKNOWN_TXT_FILE RCH 22 2000800A RECO_INVALID_FORM RECO 363 2000800B BCD_PROCESS_ERROR2 BCD 600 2000800B CCDM_INVALID_FRM_LOAD CCDM 619 2000800B EDS_ERROR_INVALID_BUFFER_LENGTH EDS 145 2000800B LDE_RKL_RKDATA_FORMAT_ERR LDE 194 2000800B PRT_NO_TEXT_NUMBER PRT 223 2000800B RCH_TXT_NOT_FOUND RCH 22 2000800B SCAN_INVALID_BOS_VERSION SCAN 237 2000800C BCD_PROCESS_ERROR3 BCD 600 2000800C CCDM_FIRMWARE_INCOMPLETE CCDM 619 2000800C EDS_ERROR_KEY_FILE EDS 145 2000800C INVALID_KEY_FILE_EXT PIN 129 2000800C LDE_RKL_LOAD_RKL_LIB_ERR LDE 195 2000800C PRT_NO_PRNSYM PRT 223 2000800C RCH_ACTCODE_NOT_FOUND RCH 23 2000800C SCAN_INVALID_IMAGE_FORMAT SCAN 238 2000800D BCD_PROCESS_ERROR4 BCD 600 2000800D CCDM_INVALID_LED CCDM 620 2000800D EDS_ERROR_NO_RESTOREFILE EDS 145 2000800D KEY_FILE_OPEN_FAILED PIN 129 2000800D LDE_CDF_LOAD_OK_INF LDE 195 2000800D PRT_INVALID_TIME PRT 223 2000800D RCH_DEFINE_TXT_NOT_FOUND RCH 23 2000800D SCAN_TMP_FILE_FAILED SCAN 238 2000800E BCD_PROCESS_ERROR5 BCD 600 2000800E CCDM_INVALID_DIM CCDM 620 2000800E EDS_ERROR_RESTORE_FILE EDS 145 2000800E LDE_ADF_LOAD_OK_INF LDE 195 2000800E PIN_INVALID_KEY_CODE PIN 129 2000800E PRT_INVALID_AGGREGATE PRT 223 2000800E RCH_THREAD_TIMEOUT RCH 23 2000800E SCAN_OUT_FILE_OPEN_FAILED SCAN 238 2000800F BCD_PROCESS_ERROR6 BCD 601 2000800F CCDM_INVALID_CAM_COLOR CCDM 620 2000800F LDE_KEY_LOAD_OK_INF LDE 195 2000800F PIN_INVALID_DECRYPTION_TYPE PIN 129 2000800F PRT_MAX_SPACE PRT 224 2000800F RCH_THREAD_CREATE_ERROR RCH 23 2000800F SCAN_IMAGE_CONVERT_FAILED SCAN 238 20008010 BCD_PROCESS_ERROR7 BCD 601 20008010 CBKM_UNEXPECTED_END CBKM 174 20008010 CCDM_INVALID_SHUTTER_STATE CCDM 620 20008010 LDE_RKLDATABIN_RENAME_ERR LDE 195 20008010 OPT_OUT_OF_ORDER OPT 186 20008010 PIN_CODE_ELEMENT_MISSING PIN 130 20008010 PRT_PRT_DLL_NOT_FOUND PRT 224

Page 697: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 689

StCode StWarn Define Device Page

20008010 RKL_ERR_WRONG_SPEC RKL 169 20008010 SCAN_INVALID_IMAGE_SECTION SCAN 238 20008011 CCDM_THREAD_START_ERROR CCDM 620 20008011 LDE_RKL_NO_RKLADF_ERR LDE 195 20008011 PIN_CODE_INVALID_OFFSET PIN 130 20008011 PRT_PRT_DLL_OPEN_FAILED PRT 224 20008011 RKL_ERR_SELECT_ADF RKL 169 20008012 CCDM_THREAD_STOP_ERROR CCDM 621 20008012 LDE_V5_ONLY_ONE_MODFILE_ERR LDE 196 20008012 PIN_CANNOT_ACCESS_KEY_FILE PIN 130 20008012 PRT_INVALID_INI_PARAM PRT 224 20008012 RKL_ERR_INTERNAL RKL 169 20008013 CCDM_INVALID_P36SIGPARA CCDM 621 20008013 LDE_DUKPTDATABIN_RENAME_ERR LDE 196 20008013 OPT_ERR_PINPAD OPT 186 20008013 PIN_THREAD_DIED PIN 130 20008013 PRT_FORMAT_ERROR PRT 224 20008014 CCDM_INVALID_CHEQUEDATA CCDM 621 20008014 LDE_DUKPT_TOKENFILE_OPEN_ERR LDE 196 20008014 PRT_INVALID_LOGICAL_ID PRT 225 20008015 CCDM_NO_CHEQUENUMBER CCDM 621 20008015 LDE_DUKPT_TOKENFILE_UID_ERR LDE 196 20008015 OPT_ERR_REC_8910 OPT 186 20008015 PRT_MALLOC_ERROR PRT 225 20008016 CCDM_ERROR_OPEN_CY_FILE CCDM 621 20008016 LDE_DUKPT_TOKENIMPORT_ERR LDE 196 20008016 OPT_ERR_AC_8910 OPT 186 20008016 PIN_INVALID_PINPAD_HARDWARE PIN 130 20008017 CCDM_ERROR_READ_CY_FILE CCDM 622 20008017 LDE_RESCLOAD_NO_FIRMWAREFILE LDE 196 20008017 PIN_INVALID_PINPAD_BEEPER PIN 130 20008018 CCDM_ERROR_WRONG_CY_FILE CCDM 622 20008018 LDE_PERMANENTKEY_RENAME_ERR LDE 197 20008018 TSC_ERROR_SHUTTER_OPEN TSC 354 20008019 CCDM_ERROR_WRONG_CY_KEY CCDM 622 20008019 LDE_PERMANENTKEY_CANT_OPEN LDE 197 20008019 OPT_ERR_CHECK_8910 OPT 187 20008019 TSC_ERROR_SHUTTER_CLOSE TSC 354 2000801A CCDM_ERROR_CY_LOAD_NEW_EMPTY CCDM 622 2000801A LDE_PERMANENTKEY_NO_KEYFILE LDE 197 2000801B CCDM_ERROR_CY_LOAD_NEW CCDM 623 2000801B LDE_RESCUELOADING_NOV5 LDE 197 2000801C CCDM_ERR_OPEN_SENS_FRM_FILE CCDM 623 2000801C LDE_RKL_ING_OPEN_ERR LDE 197 2000801D CCDM_ERR_RD_SENS_FRM_FILE CCDM 623 2000801D LDE_RKL_ING_RENAME_ERR LDE 197 2000801E CCDM_ERR_WRONG_SENS_FRM_FILE CCDM 623 2000801E LDE_RKL_ING_UID_ERR LDE 198

Page 698: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

690 June 2004

StCode StWarn Define Device Page

2000801F CCDM_INVALID_SENS_FRM_LOAD CCDM 624 2000801F COUT_INVALID_PARA COUT 589 2000801F LDE_RKL_ING_HASH_ERR LDE 198 20008020 BCD_INVALID_HANDLE2 BCD 601 20008020 CCDM_ERR_WRONG_NOTE_TABLE CCDM 624 20008020 LDE_RKL_ING_KCV_ERR LDE 198 20008020 OPT_ERR_PUT_GROUP OPT 187 20008021 BCD_INVALID_RESP2_XSUM BCD 601 20008021 CCDM_ERR_TO_MUCH_NOTES CCDM 624 20008021 LDE_RKL_ING_CFG_ERR LDE 198 20008021 OPT_ERR_REC_8912 OPT 187 20008022 BCD_INVALID_RESP2_RES1 BCD 602 20008022 CCDM_TMO_READ_SIGID CCDM 624 20008022 OPT_ERR_CHECK_8912 OPT 187 20008023 BCD_INVALID_RESP2_RES2 BCD 602 20008023 CCDM_INVALID_CHEQUE_COUNT CCDM 625 20008023 OPT_ERR_AC_8912 OPT 187 20008024 BCD_INVALID_RESP2_RES3 BCD 602 20008024 CCDM_ERR_UNPROCCESSED_SHEETS CCDM 625 20008025 BCD_INVALID_RESP2_RES4 BCD 602 20008025 CCDM_ERR_UNPROCCESSED_NOTES CCDM 625 20008026 CCDM_ERR_OPEN_FRM_FILE CCDM 625 20008027 CCDM_ERR_RD_FRM_FILE CCDM 626 20008030 CCDM_P36_ERR_CHKSUM CCDM 626 20008031 CNG_EXT_CAS1_BUNDLE_REJECT CNG_EXT 556 20008032 CNG_EXT_CAS2_BUNDLE_REJECT CNG_EXT 557 20008033 CNG_EXT_CAS3_BUNDLE_REJECT CNG_EXT 557 20008034 CNG_EXT_CAS4_BUNDLE_REJECT CNG_EXT 557 20008035 CNG_EXT_CAS5_BUNDLE_REJECT CNG_EXT 557 20008036 CNG_EXT_CAS6_BUNDLE_REJECT CNG_EXT 557 20008041 CNG_EXT_CAS1_NO_SEPARATION CNG_EXT 557 20008042 CNG_EXT_CAS2_NO_SEPARATION CNG_EXT 558 20008043 CNG_EXT_CAS3_NO_SEPARATION CNG_EXT 558 20008044 CNG_EXT_CAS4_NO_SEPARATION CNG_EXT 558 20008045 CNG_EXT_CAS5_NO_SEPARATION CNG_EXT 558 20008046 CNG_EXT_CAS6_NO_SEPARATION CNG_EXT 558 20008061 CNG_EXT_CAS1_EEPROM_ERR CNG_EXT 558 20008062 CNG_EXT_CAS2_EEPROM_ERR CNG_EXT 559 20008063 CNG_EXT_CAS3_EEPROM_ERR CNG_EXT 559 20008064 CNG_EXT_CAS4_EEPROM_ERR CNG_EXT 559 20008065 CNG_EXT_CAS5_EEPROM_ERR CNG_EXT 559 20008066 CNG_EXT_CAS6_EEPROM_ERR CNG_EXT 559 20008070 CNG_EXT_CONTAM_MS CNG_EXT 559 20008071 CNG_EXT_DEDUC_FLAG_LAM1 CNG_EXT 560 20008072 CNG_EXT_DEDUC_FLAG_LAM2 CNG_EXT 560 20008073 CNG_EXT_DEDUC_FLAG_LAM3 CNG_EXT 560 20008074 CNG_EXT_DEDUC_FLAG_LAM4 CNG_EXT 560 20008075 CNG_EXT_DEDUC_FLAG_LAM5 CNG_EXT 560

Page 699: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 691

StCode StWarn Define Device Page

20008076 CNG_EXT_DEDUC_FLAG_LAM6 CNG_EXT 560 20008081 CNG_EXT_EMPTY_FLAG_KL1 CNG_EXT 561 20008082 CNG_EXT_EMPTY_FLAG_KL2 CNG_EXT 561 20008083 CNG_EXT_EMPTY_FLAG_KL3 CNG_EXT 561 20008084 CNG_EXT_EMPTY_FLAG_KL4 CNG_EXT 561 20008085 CNG_EXT_EMPTY_FLAG_KL5 CNG_EXT 561 20008086 CNG_EXT_EMPTY_FLAG_KL6 CNG_EXT 561 20008090 CNG_EXT_CONTAM_LB1 CNG_EXT 562 20008091 CNG_EXT_CONTAM_LB18 CNG_EXT 562 20008092 CNG_EXT_CONTAM_LB19 CNG_EXT 562 20008093 CNG_EXT_CONTAM_LB21 CNG_EXT 562 20008094 CNG_EXT_CONTAM_LB22 CNG_EXT 562 20008095 CNG_EXT_CONTAM_LB26 CNG_EXT 562 20008096 CNG_EXT_CONTAM_LB33 CNG_EXT 563 20008097 CNG_EXT_CONTAM_LB35 CNG_EXT 563 20008098 CNG_EXT_CONTAM_LB27 CNG_EXT 563 20008099 CNG_EXT_CONTAM_LB28 CNG_EXT 563 2000809A CNG_EXT_CONTAM_LB29 CNG_EXT 563 2000809B CNG_EXT_CONTAM_LB36 CNG_EXT 563 2000809C CNG_EXT_CONTAM_LB37 CNG_EXT 564 200080FF COUT_HOPPER_NOT_CONFIGURED COUT 589 20008100 CIN_PROTOCOL_TX_TIMEOUT CIN 593 20008100 CM3K_ERROR_INIT CM3K 340 20008100 COUT_PROTOCOL_TX_TIMEOUT COUT 589 20008100 MDM_MEMORY_ALLOC_ERROR MDM 661 20008100 PRT_INVALID_LED PRT 225 20008100 PRT_NO_GRAPHIC ND97 263 20008100 RJ03_INVALID_RESPONSE RJ03 323 20008100 SCAN_RUL_INVALID_FILENAME SCAN 239 20008101 CIN_PROTOCOL_RX_TIMEOUT CIN 593 20008101 CM3K_ERROR_TIMEOUT_FW CM3K 340 20008101 COUT_PROTOCOL_RX_TIMEOUT COUT 590 20008101 EDM_VEM_NOT_INIT EDM 147 20008101 MDM_LB_NOT_INSTALLED MDM 661 20008101 PPD_MEMORY_ALLOC_ERROR PPD 667 20008101 PRT_NO_MONITOR_MODE ND97 263 20008101 RJ03_MALLOC_ERROR RJ03 323 20008101 SCAN_RUL_INVALID_CMD_LINE_ARG SCAN 239 20008102 CIN_INVALID_ACK_TYPE CIN 593 20008102 COUT_INVALID_ACK_TYPE COUT 590 20008102 DPS_INVALID_DATA_ACCESS DPS 605 20008102 EDM_INVALID_BLK_LEN EDM 147 20008102 MDM_COMMUNICATION_ERROR MDM 661 20008102 PPD_INVALID_RX_DATA PPD 667 20008102 PRT_MONITOR_RUNNING ND97 263 20008102 RJ03_READ_TIMEOUT RJ03 323 20008102 SCAN_RUL_CTRL_FILE_OPEN_ERROR SCAN 239 20008103 CIN_MAX_TX_RETRIES CIN 594

Page 700: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

692 June 2004

StCode StWarn Define Device Page

20008103 COUT_MAX_TX_RETRIES COUT 590 20008103 EDM_INVALID_CMD EDM 147 20008103 PPD_INVALID_FRM_DATA PPD 668 20008103 PRT_MONITOR_WRONG_PROCESS ND97 264 20008103 RJ03_CODE_PAGE RJ03 324 20008103 SCAN_RUL_DLD_FILE_OPEN_ERROR SCAN 239 20008104 CIN_MAX_RX_RETRIES CIN 594 20008104 COUT_MAX_RX_RETRIES COUT 590 20008104 DPS_INVALID_CANCEL DPS 605 20008104 EDM_INVALID_PARA EDM 148 20008104 PPD_INVALID_FRM_FILE_MOD PPD 668 20008104 RJ03_INVALID_FILE RJ03 324 20008104 SCAN_RUL_CTRL_FILE_READ_ERROR SCAN 239 20008105 COUT_TOO_MANY_COINS COUT 590 20008105 DPS_FRM_FILE_OPEN_FAILED DPS 605 20008105 EDM_INVALID_KEY_NO EDM 148 20008105 PPD_CTF_FILE_NOT_FOUND PPD 668 20008105 RJ03_FILE_ACCESS_ERROR RJ03 324 20008105 SCAN_RUL_DLD_FILE_READ_ERROR SCAN 239 20008106 COUT_LOW_LEVEL_SET COUT 591 20008106 DPS_FRM_FILE_ACCESS_ERROR DPS 605 20008106 PPD_FRM_FILE_NOT_FOUND PPD 668 20008106 RJ03_INVALID_LOADED_FILE RJ03 324 20008106 SCAN_RUL_CTRL_FILE_INVALID_CMD SCAN 240 20008107 COUT_INVALID_LED COUT 591 20008107 DPS_INVALID_FRM_FILE_DATA DPS 606 20008107 EDM_INVALID_FRM_DATA EDM 148 20008107 PPD_CTF_FILE_OPEN_FAILED PPD 668 20008107 RJ03_OFFLINE RJ03 324 20008107 SCAN_RUL_DRV_WRITE_ERROR SCAN 240 20008108 DPS_INVALID_FILE_CHKSUM DPS 606 20008108 PPD_FRM_FILE_OPEN_FAILED PPD 668 20008108 RJ03_NO_DEVICE RJ03 325 20008109 PPD_INVALID_CTF_FILE_DATA PPD 669 2000810B EDM_INVALID_IV_LEN EDM 148 2000810C EDM_NO_IV_SPACE EDM 148 2000810D PRT_FRM_FILE_MOD ND99 275 2000810E EDM_MEMORY_ALLOC_ERROR EDM 149 2000810E PRT_INVALID_FIRMWARE_FILE ND99 275 20008110 CM3K_PAPER_TRAY CM3K 341 20008110 PRT_WRONG_FIRMWARE_LOADED ND99 275 20008111 EDM_PIN_INVALID_MAX_LEN EDM 149 20008111 PRT_MORE_ERRORS ND94 257 20008112 EDM_PIN_INVALID_MIN_LEN EDM 149 20008112 PRT_INVALID_MSGID HPEM 287 20008113 EDM_PIN_INVALID_ZERO_CMD EDM 149 20008114 EDM_PIN_INVALID_QUIT_CMD EDM 149 20008115 EDM_PIN_INVALID_MODE EDM 149

Page 701: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 693

StCode StWarn Define Device Page

20008116 EDM_PIN_INVALID_POS EDM 150 20008117 PRT_WRONG_MODE ND05 227 20008118 EDM_PIN_INVALID_TESTMODE EDM 150 20008118 PRT_ZEKOSA_WRITE_ERROR ND05 227 20008119 EDM_PIN_INVALID_PINLEN EDM 150 20008119 PRT_ZEKOSA_READ_LRC ND05 227 2000811A EDM_DLL_INVALID_API EDM 150 2000811B EDM_DLL_PROC_NOT_FOUND EDM 150 2000811C EDM_DLL_ACCESS_DENIED EDM 151 2000811E EDM_INVALID_DATA_ACCESS EDM 151 2000811F EDM_INVALID_IV_MODE EDM 151 20008120 EDM_PROTOCOL_TIMEOUT EDM 151 20008120 PRT_ZEKOSA_READ_PARITY ND05 228 20008120 TH21_COMMUNICATION_ERROR TH21 281 20008121 EDM_MAX_RX_RETRIES EDM 151 20008121 PRT_ZEKOSA_READ_NO_DATA ND05 228 20008121 TH21_NO_DRIVER_FOUND TH21 281 20008122 EDM_INVALID_ACK_TYPE EDM 152 20008122 PRT_ZEKOSA_READ_NO_STX ND05 228 20008122 TH21_INVALID_PORT TH21 281 20008123 EDM_PROTOCOL_ERROR EDM 152 20008123 PRT_ZEKOSA_READ_ERROR ND05 228 20008124 EDM_INVALID_PAIR_OF_KGK EDM 152 20008125 EDM_INVALID_KGK_VALUE EDM 152 20008126 EDM_ERROR_MK_CHECK EDM 153 20008127 EDM_INVALID_MAC EDM 153 20008128 EDM_ALREADY_IN_USE EDM 153 20008129 EDM_MALLOC_ERROR EDM 153 2000812A EDM_KEYTABLE_FULL EDM 153 2000812B EDM_INVALID_KEYNAME EDM 153 2000812C EDM_IMPORT_WRONG_TYPE EDM 154 2000812D EDM_BUFFER_OVERFLOW EDM 154 20008151 CNG_EXT_CAS1_MULTIPLE_NOTES CNG_EXT 564 20008152 CNG_EXT_CAS2_MULTIPLE_NOTES CNG_EXT 564 20008153 CNG_EXT_CAS3_MULTIPLE_NOTES CNG_EXT 564 20008154 CNG_EXT_CAS4_MULTIPLE_NOTES CNG_EXT 564 20008155 CNG_EXT_CAS5_MULTIPLE_NOTES CNG_EXT 564 20008156 CNG_EXT_CAS6_MULTIPLE_NOTES CNG_EXT 565 20008200 CM3K_INVALID_FIRMWARE_FILE CM3K 341 20008200 DPS_PROTOCOL_WRITE_TIMEOUT DPS 606 20008200 HPEM_PROTOCAL_TX_TIMEOUT HPEM 287 20008201 CM3K_ERROR_LOAD_FIRMWARE CM3K 341 20008201 DPS_PROTOCOL_READ_TIMEOUT DPS 606 20008201 HPEM_PROTOCOL_RX_TIMEOUT HPEM 287 20008201 LDR_INI_FILE_OPEN_FAILED ND71 245 20008201 TH21_INI_FILE_OPEN_FAILED TH21 281 20008202 DPS_MAX_TX_RETRIES DPS 606 20008202 EDM_APSS_INVALID_KEY_TYPE EDM 154

Page 702: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

694 June 2004

StCode StWarn Define Device Page

20008202 HPEM_INVALID_ACK_TYPE HPEM 288 20008202 LDR_INI_FILE_READ_ERROR ND71 245 20008202 TH21_INI_FILE_READ_ERROR TH21 282 20008203 DPS_MAX_RX_RETRIES DPS 607 20008203 LDR_INVALID_FILE ND71 245 20008203 TH21_INVALID_FILE TH21 282 20008204 DPS_MAX_CDM_RETRIES DPS 607 20008204 LDR_FILE_ACCESS_ERROR ND71 246 20008204 TH21_FILE_ACCESS_ERROR TH21 282 20008205 DPS_INVALID_ACK_TYPE DPS 607 20008205 LDR_INVALID_MODID ND71 246 20008205 TH21_INVALID_MODID TH21 282 20008206 DPS_PROTOCOL_ENQ_TIMEOUT DPS 607 20008206 LDR_FRM_LOADER_NOT_READY ND71 246 20008206 TH21_FRM_LOADER_NOT_READY TH21 282 20008207 DPS_INVALID_FRM_DATA DPS 608 20008207 LDR_INVALID_LOADED_FILE ND71 246 20008207 TH21_INVALID_LOADED_FILE TH21 282 20008208 DPS_ERROR_SEM_TIMEOUT DPS 608 20008208 LDR_INVALID_FIRMWARE ND71 246 20008208 TH21_SERVER_ERROR TH21 283 20008209 DPS_PROTOCOL_CAN_TIMEOUT DPS 608 20008209 TH21_LM_WRITE_ERROR TH21 283 2000820A TH21_LM_READ_ERROR TH21 283 20008251 CNG_EXT_CAS1_OUT_WIDTH_TOL CNG_EXT 565 20008252 CNG_EXT_CAS2_OUT_WIDTH_TOL CNG_EXT 565 20008253 CNG_EXT_CAS3_OUT_WIDTH_TOL CNG_EXT 565 20008254 CNG_EXT_CAS4_OUT_WIDTH_TOL CNG_EXT 565 20008255 CNG_EXT_CAS5_OUT_WIDTH_TOL CNG_EXT 565 20008256 CNG_EXT_CAS6_OUT_WIDTH_TOL CNG_EXT 566 20008300 CNG_EXT_COLL_TRAY_NOT_EMPTY_DIV CNG_EXT 566 20008300 DPS_INVALID_LED DPS 608 20008300 EDM_FRMLD_IN_PROGRESS EDM 154 20008301 EDM_FRMLD_NBR EDM 154 20008302 EDM_FRMLD_RNR EDM 154 20008303 EDM_FRMLD_SNR EDM 155 20008304 EDM_FRMLD_DIST EDM 155 20008305 EDM_FRMLD_FORMAT EDM 155 20008306 EDM_FRMLD_LOADER EDM 155 20008307 EDM_FRMLD_CMDSEQ EDM 155 20008312 CNG_EXT_SAFE_CIRC_BRK_OPEN_DIV CNG_EXT 566 20008313 CNG_EXT_DLOC_YES_DIV CNG_EXT 566 20008314 CNG_EXT_CONFIG_DIVERTER CNG_EXT 566 20008315 CNG_EXT_RIGHT_OCCUPIED_DIVERTER CNG_EXT 567 20008316 CNG_EXT_LEFT_OCCUPIED_DIVERTER CNG_EXT 567 20008318 CNG_EXT_JAM_DISPENSE_DIV CNG_EXT 567 20008319 CNG_EXT_JAM_TRANS_DIVERTER CNG_EXT 567 20008320 CNG_EXT_SINGLE_REJ_DEFECT_DIV CNG_EXT 567

Page 703: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 695

StCode StWarn Define Device Page

20008321 CNG_EXT_MS_DEFECT_DIV CNG_EXT 568 20008322 CNG_EXT_LBAMP_DEFECT_DIV CNG_EXT 568 20008323 CNG_EXT_RESET_RW_DEFECT_DIV CNG_EXT 568 20008324 CNG_EXT_RESET_RR_DEFECT_DIV CNG_EXT 568 20008325 CNG_EXT_VMOTOR_DEFECT_DIV CNG_EXT 568 20008326 CNG_EXT_COL_TRAY_DEFECT_DIV CNG_EXT 569 20008328 CNG_EXT_TRANS_ERR_DIVERTER CNG_EXT 569 20008329 CNG_EXT_JAM_COLL_TRAY_DIV CNG_EXT 569 20008331 CNG_EXT_CAS1_BUNDLE_REJECT_DIV CNG_EXT 569 20008332 CNG_EXT_CAS2_BUNDLE_REJECT_DIV CNG_EXT 569 20008333 CNG_EXT_CAS3_BUNDLE_REJECT_DIV CNG_EXT 569 20008334 CNG_EXT_CAS4_BUNDLE_REJECT_DIV CNG_EXT 570 20008335 CNG_EXT_CAS5_BUNDLE_REJECT_DIV CNG_EXT 570 20008336 CNG_EXT_CAS6_BUNDLE_REJECT_DIV CNG_EXT 570 20008341 CNG_EXT_CAS1_NO_SEPARATION_DIV CNG_EXT 570 20008342 CNG_EXT_CAS2_NO_SEPARATION_DIV CNG_EXT 570 20008343 CNG_EXT_CAS3_NO_SEPARATION_DIV CNG_EXT 571 20008344 CNG_EXT_CAS4_NO_SEPARATION_DIV CNG_EXT 571 20008345 CNG_EXT_CAS5_NO_SEPARATION_DIV CNG_EXT 571 20008346 CNG_EXT_CAS6_NO_SEPARATION_DIV CNG_EXT 571 20008351 CNG_EXT_CAS1_MULTIPLE_NOTES_DIV CNG_EXT 571 20008352 CNG_EXT_CAS2_MULTIPLE_NOTES_DIV CNG_EXT 572 20008353 CNG_EXT_CAS3_MULTIPLE_NOTES_DIV CNG_EXT 572 20008354 CNG_EXT_CAS4_MULTIPLE_NOTES_DIV CNG_EXT 572 20008355 CNG_EXT_CAS5_MULTIPLE_NOTES_DIV CNG_EXT 572 20008356 CNG_EXT_CAS6_MULTIPLE_NOTES_DIV CNG_EXT 572 20008361 CNG_EXT_CAS1_EEPROM_ERR_DIV CNG_EXT 573 20008362 CNG_EXT_CAS2_EEPROM_ERR_DIV CNG_EXT 573 20008363 CNG_EXT_CAS3_EEPROM_ERR_DIV CNG_EXT 573 20008364 CNG_EXT_CAS4_EEPROM_ERR_DIV CNG_EXT 573 20008365 CNG_EXT_CAS5_EEPROM_ERR_DIV CNG_EXT 573 20008366 CNG_EXT_CAS6_EEPROM_ERR_DIV CNG_EXT 573 20008370 CNG_EXT_CONTAM_MS_DIV CNG_EXT 574 20008371 CNG_EXT_DEDUC_FLAG_LAM1_DIV CNG_EXT 574 20008372 CNG_EXT_DEDUC_FLAG_LAM2_DIV CNG_EXT 574 20008373 CNG_EXT_DEDUC_FLAG_LAM3_DIV CNG_EXT 574 20008374 CNG_EXT_DEDUC_FLAG_LAM4_DIV CNG_EXT 574 20008375 CNG_EXT_DEDUC_FLAG_LAM5_DIV CNG_EXT 575 20008376 CNG_EXT_DEDUC_FLAG_LAM6_DIV CNG_EXT 575 20008381 CNG_EXT_EMPTY_FLAG_KL1_DIV CNG_EXT 575 20008382 CNG_EXT_EMPTY_FLAG_KL2_DIV CNG_EXT 575 20008383 CNG_EXT_EMPTY_FLAG_KL3_DIV CNG_EXT 575 20008384 CNG_EXT_EMPTY_FLAG_KL4_DIV CNG_EXT 576 20008385 CNG_EXT_EMPTY_FLAG_KL5_DIV CNG_EXT 576 20008386 CNG_EXT_EMPTY_FLAG_KL6_DIV CNG_EXT 576 20008390 CNG_EXT_CONTAM_LB1_DIV CNG_EXT 576 20008391 CNG_EXT_CONTAM_LB18_DIV CNG_EXT 576 20008392 CNG_EXT_CONTAM_LB19_DIV CNG_EXT 577

Page 704: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

696 June 2004

StCode StWarn Define Device Page

20008393 CNG_EXT_CONTAM_LB21_DIV CNG_EXT 577 20008394 CNG_EXT_CONTAM_LB22_DIV CNG_EXT 577 20008395 CNG_EXT_CONTAM_LB26_DIV CNG_EXT 577 20008396 CNG_EXT_CONTAM_LB33_DIV CNG_EXT 577 20008397 CNG_EXT_CONTAM_LB35_DIV CNG_EXT 578 20008398 CNG_EXT_CONTAM_LB27_DIV CNG_EXT 578 20008399 CNG_EXT_CONTAM_LB28_DIV CNG_EXT 578 2000839A CNG_EXT_CONTAM_LB29_DIV CNG_EXT 578 2000839B CNG_EXT_CONTAM_LB36_DIV CNG_EXT 578 2000839C CNG_EXT_CONTAM_LB37_DIV CNG_EXT 579 20008400 CNG_EXT_OUTPUT_NOT_EMPTY_DIV CNG_EXT 579 20008400 SEL_INVALID_ERROR_CODE SEL 115 20008405 SEL_CSCCNG_DLL_NOT_FOUND SEL 115 20008407 SEL_THREAD_ERROR SEL 115 20008408 SEL_QUEUE_FULL SEL 116 20008409 SEL_WRONG_READY_IND_SYNCRO SEL 116 20008410 SEL_ASKIM_START_ERROR SEL 116 20008419 CNG_EXT_JAM_TRANS_DIV_OCCUP CNG_EXT 579 20008FFF MDM_INVALID_ERROR_DATA MDM 662 20009000 CIT_INVALID_RESPONSE CIT 141 20009000 COUT_WARN_LED COUT 591 20009000 DFU_ERR_DEVICE_IS_NOT_DOWNLOAD_CAPABLE DFU 83 20009000 PRT_WARN_LED PRT 225 20009001 CIT_INVALD_DATA CIT 141 20009001 CM3K_ERROR_BADSETUP CM3K 341 20009001 DFU_ERR_DEVICE_IS_NOT_UPLOAD_CAPABLE DFU 83 20009001 S500_SERVER_SYS_ERR S500 330 20009001 TSC_ERROR_CMD TSC 355 20009002 CIT_BUFFER_OVERFLOW CIT 141 20009002 CM3K_ERROR_FEEDEREMPTY CM3K 341 20009002 DFU_ERR_OPENING_FIRMWARE_FILE DFU 83 20009002 S500_SCSI_ERR S500 330 20009003 CIT_NO_CURSOR_POS_SAVED CIT 141 20009003 CM3K_ERROR_DOCINTRACK CM3K 342 20009003 DFU_ERR_READING_FIRMWARE_FILE DFU 83 20009003 S500_PERIF_NOT_FOUND S500 330 20009003 TSC_ERROR_EJECT TSC 355 20009004 CIT_NO_RESPONSE CIT 142 20009004 CM3K_ERROR_ALREADYACTIVE CM3K 342 20009004 DFU_ERR_WRITING_FIRMWARE_FILE DFU 84 20009004 S500_HARD_ERR S500 330 20009004 TSC_ERROR_TIMEOUT TSC 355 20009005 CIT_WRONG_INIT_IOPORT CIT 142 20009005 CM3K_ERROR_DISABLED CM3K 342 20009005 DFU_ERR_CORRUPT_FIRMWARE_FILE DFU 84 20009005 S500_PERIF_OFF_ON S500 330 20009005 TSC_ERROR_MISSING_FORM TSC 355 20009006 CIT_CSCNPORT_DRIVER_NOT_FOUND CIT 142

Page 705: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 697

StCode StWarn Define Device Page

20009006 CM3K_ERROR_FEEDERJAM CM3K 342 20009006 DFU_ERR_FALSE_SPEC_VERSION DFU 84 20009006 S500_RESERV_ERR S500 331 20009006 TSC_ERROR_SCANNER TSC 355 20009007 CM3K_ERROR_TRACKWATCHDOG CM3K 343 20009007 DFU_ERR_NO_VALID_DFU_SIGNATURE DFU 84 20009007 S500_BOURRAGE S500 331 20009007 TSC_ERROR_BUSY TSC 356 20009008 CM3K_ERROR_CANT_RECOVER CM3K 343 20009008 DFU_ERR_SUFFIX_HAS_NOT_RIGHT_SIZE DFU 84 20009008 S500_DOC_FEED_ERR S500 331 20009008 TSC_SERIAL_ERROR TSC 356 20009009 DFU_ERR_VID_DOES_NOT_MATCH DFU 84 20009009 S500_INVALID_CMD S500 331 20009009 TSC_ERROR_SHUTTER TSC 356 2000900A CM3K_ERROR_JAM CM3K 343 2000900A DFU_ERR_PID_DOES_NOT_MATCH DFU 85 2000900A S500_DATA_LOST S500 331 2000900A TSC_ERROR_CCD TSC 356 2000900B CM3K_ERROR_TIMEOUT CM3K 343 2000900B DFU_ERR_FALSE_DESCRIPTOR_TYPE DFU 85 2000900B S500_EXEC_CMD S500 332 2000900B TSC_ERROR_LS TSC 356 2000900C CM3K_ERROR_DOUBLE CM3K 343 2000900C DFU_ERR_INSUFFICIENT_MEMORY DFU 85 2000900C S500_JPEG_ERROR S500 332 2000900D CM3K_ERROR_FILEWRITE CM3K 344 2000900D DFU_ERR_DEVICE_DOES_NOT_SUPPORT_DFU DFU 85 2000900D S500_CMD_SEQUENCE_ERROR S500 332 2000900D TSC_STARTUP_OCCURED TSC 357 2000900E CM3K_ERROR_SCSI CM3K 344 2000900E DFU_ERR_DEVICE_NOT_READY_FOR_DOWNLOAD DFU 85 2000900E S500_NOT_USED S500 332 2000900F CM3K_ERROR_IMAGECALLBACK CM3K 344 2000900F DFU_ERR_DEVICE_NOT_READY_FOR_UPLOAD DFU 85 2000900F S500_INVALID_HANDLE S500 332 20009010 CM3K_ERROR_INTERNAL CM3K 344 20009010 DFU_ERR_DEVICE_IS_PERMANENT_BUSY DFU 86 20009010 S500_OPEN_NOT_DONE S500 332 20009011 CM3K_ERROR_UNKNOWN CM3K 345 20009011 DFU_ERR_CANNOT_START_TRANSFER DFU 86 20009011 S500_NO_LIBRARY_LOAD S500 333 20009012 CM3K_ERROR_ALLOCBIN CM3K 345 20009012 DFU_ERR_INVALID_INTERFACE_DESCRIPTOR DFU 86 20009012 S500_RESOLUTON_NOT_SUPPORTED S500 333 20009013 CM3K_ERROR_G4ENCODE CM3K 345 20009013 S500_ILLEGAL_MOVEMENT S500 333 20009014 CM3K_ERROR_NODOKUMENTDATA CM3K 345

Page 706: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

698 June 2004

StCode StWarn Define Device Page

20009014 S500_PERIPHERAL_TIMEOUT S500 333 20009015 CM3K_ERROR_TREATMENT CM3K 345 20009015 S500_BMP_ERROR S500 333 20009016 CM3K_ERROR_DOCLONGFOROP CM3K 346 20009016 S500_TIFF_ERROR S500 333 20009017 CM3K_ERROR_OCRHEADPROBLEM CM3K 346 20009017 S500_MISSING_IMAGE S500 334 20009018 CM3K_ERROR_BADDEVICE CM3K 346 20009018 S500_INVALID_TYPE S500 334 20009019 CM3K_ERROR_EXTSHUTTER CM3K 346 20009019 S500_INVALID_SAVEMODE S500 334 2000901A CM3K_ERROR_INTSHUTTER CM3K 347 2000901A S500_INVALID_PAGE_NUMBER S500 334 2000901B CM3K_ERROR_METALDETECTOR CM3K 347 2000901B S500_INVALID_TYPE_COMMAND S500 334 2000901C CM3K_ERROR_RIBBONCART CM3K 347 2000901C S500_INVALID_STEP S500 334 2000901D CM3K_ERROR_WRONG_TRACKCOMM CM3K 347 2000901D S500_INVALID_DOC_HANDLING S500 335 2000901E CM3K_ERROR_WRONG_EJECT CM3K 348 2000901E S500_INVALID_DRAWER S500 335 20009064 S500_PERIPHERAL_NOT_ANSWER S500 335 200090FF CM3K_ERROR_UNDEF CM3K 348 20009102 S500_DATATRUNC S500 335 20009104 S500_ALREADY_OPEN S500 335 20009108 S500_NO_ENDCMD S500 335 2000910A S500_NOSENSE S500 336 2000910C S500_TARGETBUSY S500 336 2000910D S500_TRY_TO_RESET S500 336 2000910F S500_STRINGTRUNCATED S500 336 20009201 CCDM_IMACON_ERROR_SYNTAX CCDM 626 20009201 CM3K_IMACON_ERROR_SYNTAX CM3K 348 20009201 S500_IMACON_ERROR_SYNTAX S500 336 20009201 TSC_IMACON_ERROR_SYNTAX TSC 357 20009202 CCDM_IMACON_ERROR_INPUT_OPEN CCDM 626 20009202 CM3K_IMACON_ERROR_INPUT_OPEN CM3K 348 20009202 S500_IMACON_ERROR_INPUT_OPEN S500 336 20009202 TSC_IMACON_ERROR_INPUT_OPEN TSC 357 20009203 CCDM_IMACON_ERROR_INPUT_READ CCDM 626 20009203 CM3K_IMACON_ERROR_INPUT_READ CM3K 348 20009203 S500_IMACON_ERROR_INPUT_READ S500 337 20009203 TSC_IMACON_ERROR_INPUT_READ TSC 357 20009204 CCDM_IMACON_ERROR_OUTPUT_OPEN CCDM 627 20009204 CM3K_IMACON_ERROR_OUTPUT_OPEN CM3K 348 20009204 S500_IMACON_ERROR_OUTPUT_OPEN S500 337 20009204 TSC_IMACON_ERROR_OUTPUT_OPEN TSC 357 20009205 CCDM_IMACON_ERROR_OUTPUT_WRITE CCDM 627 20009205 CM3K_IMACON_ERROR_OUTPUT_WRITE CM3K 349

Page 707: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 699

StCode StWarn Define Device Page

20009205 S500_IMACON_ERROR_OUTPUT_WRITE S500 337 20009205 TSC_IMACON_ERROR_OUTPUT_WRITE TSC 357 20009206 CCDM_IMACON_ERROR_MEMORY CCDM 627 20009206 CM3K_IMACON_ERROR_MEMORY CM3K 349 20009206 S500_IMACON_ERROR_MEMORY S500 337 20009206 TSC_IMACON_ERROR_MEMORY TSC 358 20009207 CCDM_IMACON_ERROR_TOO_LONG CCDM 627 20009207 CM3K_IMACON_ERROR_TOO_LONG CM3K 349 20009207 S500_IMACON_ERROR_TOO_LONG S500 337 20009207 TSC_IMACON_ERROR_TOO_LONG TSC 358 20009208 CCDM_IMACON_ERROR_TOO_LARGE CCDM 627 20009208 CM3K_IMACON_ERROR_TOO_LARGE CM3K 349 20009208 S500_IMACON_ERROR_TOO_LARGE S500 337 20009208 TSC_IMACON_ERROR_TOO_LARGE TSC 358 20009209 CCDM_IMACON_ERROR_TOO_SMALL CCDM 627 20009209 CM3K_IMACON_ERROR_TOO_SMALL CM3K 349 20009209 S500_IMACON_ERROR_TOO_SMALL S500 338 20009209 TSC_IMACON_ERROR_TOO_SMALL TSC 358 2000920A CCDM_IMACON_ERROR_TIFFCONV CCDM 628 2000920B CCDM_IMACON_ERROR_TEMPFILE CCDM 628 2000920C CCDM_IMACON_ERROR_DLL_LOAD CCDM 628 200092E0 CCDM_IMACON_ERROR_JPG CCDM 628 200092F0 CCDM_IMACON_ERROR_RECO CCDM 628 200092FF CCDM_IMACON_UNDEF_ERROR CCDM 628 200092FF CM3K_IMACON_UNDEF_ERROR CM3K 349 200092FF S500_IMACON_UNDEF_ERROR S500 338 200092FF TSC_IMACON_UNDEF_ERROR TSC 358 20009300 CCDM_DQF_ERR_ILLEGAL_PARAM CCDM 629 20009300 CM3K_DQF_ERR_ILLEGAL_PARAM CM3K 350 20009300 TSC_DQF_ERR_ILLEGAL_PARAM TSC 358 20009301 CCDM_DQF_ERR_NO_MEMORY CCDM 629 20009301 CM3K_DQF_ERR_NO_MEMORY CM3K 350 20009301 TSC_DQF_ERR_NO_MEMORY TSC 359 20009302 CCDM_DQF_ERR_HGHLOW_INVALID CCDM 629 20009302 CM3K_DQF_ERR_HGHLOW_INVALID CM3K 350 20009302 TSC_DQF_ERR_HGHLOW_INVALID TSC 359 20009303 CCDM_DQF_ERR_LOWEFFECTIVELEVEL_RANGE CCDM 629 20009303 CM3K_DQF_ERR_LOWEFFECTIVELEVEL_RANGE CM3K 350 20009303 TSC_DQF_ERR_LOWEFFECTIVELEVEL_RANGE TSC 359 20009304 CCDM_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE CCDM 629 20009304 CM3K_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE CM3K 350 20009304 TSC_DQF_ERR_HIGHEFFECTIVELEVEL_RANGE TSC 359 20009305 CCDM_DQF_ERR_SENSITIVNESS_RANGE CCDM 629 20009305 CM3K_DQF_ERR_SENSITIVNESS_RANGE CM3K 350 20009305 TSC_DQF_ERR_SENSITIVNESS_RANGE TSC 359 200093FF CCDM_DQF_UNDEF_ERROR CCDM 630 200093FF CM3K_DQF_UNDEF_ERROR CM3K 351 200093FF TSC_DQF_UNDEF_ERROR TSC 359

Page 708: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

700 June 2004

StCode StWarn Define Device Page

2000A000 CNG_EXT_TRANS_LB_UE_COV CNG_EXT 579 2000A001 SEV4_CSE_DEV_NOT_AVAILABLE SEL 116 2000A002 SEV4_CCB_DEV_NOT_AVAILABLE SEL 117 2000A003 SEV4_CSE_PORT_NOT_AVAILABLE SEL 117 2000A004 SEV4_CCB_PORT_NOT_AVAILABLE SEL 117 2000A005 SEV4_ILLEGAL_CSE_PORT SEL 117 2000A006 SEV4_ILLEGAL_CCB_PORT SEL 117 2000A007 SEV4_ILLEGAL_PARAMETER SEL 118 2000A008 SEV4_ILLEGAL_SOUND_PARA SEL 118 2000A009 SEV4_ILLEGAL_MEI_PARA SEL 118 2000A010 SEV4_WRONG_KEY_PARITY SEL 118 2000A020 SEV4_INVALID_LCD_CONFIG SEL 118 2000A021 SEV4_INVALID_LOGO_CONFIG SEL 119 2000A022 SEV4_INVALID_RESRET_CONFIG SEL 119 2000A023 SEV4_INVALID_MEI_CONFIG SEL 119 2000A024 SEV4_INVALID_MEI_FLASHING SEL 119 2000A030 SEV4_INVALID_DATA SEL 120 2000A040 SEV4_THREAD_ERROR SEL 120 2000A050 SEV4_EVENT_NO_RESOURCE SEL 120 2000A051 SEV4_EVENT_INVALID_USER SEL 120 2000A100 CNG_EXT_SYNTAX_ERROR CNG_EXT 579 2000A200 CNG_EXT_INVALID_PROG CNG_EXT 580 2000B000 EST_INVALID_STCLASS EST 25 2000B001 EST_INVALID_STCODE EST 25 2000B002 EST_INVALID_RANGE EST 25 2000B003 EST_INVALID_COUNTER EST 26 2000B004 EST_INVALID_ACTIVE EST 26 2000B005 EST_INVALID_BUF_LEN EST 26 2000B006 EST_INVALID_PCSCDHLPARA EST 26 2000B007 EST_BUFFER_OVERFLOW EST 26 2000B008 EST_THREAD_NOT_STARTED EST 27 2000B009 EST_CORRUPT_FILE EST 27 2000B00A EST_TLS_ERROR EST 27 2000B00C EST_CANNOT_OPEN_FILE EST 27 2000B00D EST_CANNOT_WRITE_FILE EST 27 2000B00E EST_OUT_OF_MEMORY EST 27 2000C000 TRA_INVALID_SELECTIONMASK TRA 29 2000C001 MSS_ILLEGAL_CHARACTER MSS 107 2000C001 TRA_UNKNOWN_GROUPNAME TRA 29 2000C002 MSS_INVALID_DES_KEY MSS 107 2000C002 TRA_OUT_OF_MEMORY TRA 29 2000C003 MSS_INVALID_KEYWORD MSS 107 2000C003 TRA_CORRUPT_NAMEFILE TRA 29 2000C004 MSS_INVALID_RESULT MSS 107 2000C004 TRA_SYNTAX_ERROR TRA 30 2000C006 TRA_CANNOT_OPEN_FILE TRA 30 2000C007 TRA_CANNOT_WRITE_FILE TRA 30 2000E001 USB_I_WIN_ERR USB 64

Page 709: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 701

StCode StWarn Define Device Page

2000E002 CNG_NO_ACTUAL_FIRMWARE CNG 493 2000E002 USB_I_INSTUSB_ERR USB 64 2000E003 CNG_NO_FIRMWARE CNG 493 2000E004 BCD_WARN_LED BCD 604 2000E004 CNG_WARN_LED CNG 494 2000E006 CNG_WARN_INSUFFICIENT_MODULES CNG 494 2000E103 IDU_FRM_NO_CARTRIDGE IDU 89 2000EF00 CNG_INVALID_RESPONSE CNG 487 2000EF01 CNG_INVALID_CRC CNG 487 2000EF02 CNG_INVALID_FRM_AUTO_LOAD CNG 487 2000EF03 CNG_INVALID_LED CNG 487 2000EF04 CNG_FIRMWARE_INCOMPLETE CNG 488 2000EF05 CNG_INVALID_CURRENCY_FILES CNG 488 2000EF06 CNG_INVALID_CUR_FILE_FORMAT CNG 488 2000EF07 CNG_INVALID_RECOVERY CNG 488 2000EF08 CNG_INVALID_VARIANT CNG 488 2000EF09 CNG_INVALID_BEB_STATISTICS CNG 488 2000EF0A CNG_INSUFFICIENT_MODULES CNG 489 2000EF0B CNG_INVALID_CHECK_MODULES CNG 489 2000EF0C CNG_INVALID_DISPENSEIN_TRACE CNG 489 2000EF0D CNG_INVALID_CURRENCY_AUTOLOAD CNG 489 2000EF0E CNG_INVALID_CURRENCY_MAP_NOTES CNG 489 2000EF0F CNG_INVALID_CONFIG_BACKUP CNG 489 2000EF10 CNG_INVALID_LOADER_CTL CNG 490 2000EF11 CNG_INVALID_BIM_TYPE CNG 490 2000EF12 CNG_OPEN_CURRENCY_FILE_FAILED CNG 490 2000EF13 CNG_READ_CURRENCY_FILE_FAILED CNG 490 2000EF14 CNG_OPEN_FIRMWARE_FILE_FAILED CNG 490 2000EF15 CNG_READ_FIRMWARE_FILE_FAILED CNG 490 2000EF16 CNG_INVALID_FRM_FILE_FORMAT CNG 491 2000F000 P36_ERR_CHKSUM2 P36 583 2000F000 P36_WARN_CHKSUM2 P36 584 2000F001 IDU_MAX_COUNT IDU 89 2000F001 P36_INVALID_SIGDATA P36 584 2000F002 IDU_TOO_LITTLE_DATA IDU 89 2000F003 IDU_INVALID_DATA IDU 90 2000F004 IDU_NO_ENQ IDU 90 2000F005 IDU_INVALID_RESPONSE IDU 90 2000F006 IDU_INVALID_STATUS IDU 90 2000F007 IDU_INVALID_PARAMETER IDU 91 2000F009 IDU_WRONG_TYPE IDU 91 2000F00B IDU_WRONG_INITPM IDU 91 2000F00C IDU_WRONG_INITPD IDU 91 2000F00D IDU_WRONG_INITWV IDU 91 2000F00E IDU_WRONG_INITSH IDU 92 2000F00F IDU_INVALID_COMMAND IDU 92 2000F011 IDU_INVALID_WRITE IDU 92 2000F012 IDU_NAK_RESPONSE IDU 92

Page 710: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

702 June 2004

StCode StWarn Define Device Page

2000F013 IDU_INVALID_CANCEL IDU 92 2000F014 IDU_NESTED_CANCEL IDU 93 2000F015 IDU_NO_CARD IDU 93 2000F016 IDU_WRONG_INITMSS IDU 93 2000F017 IDU_MSS_DLL_LOAD_FAILED IDU 93 2000F018 IDU_WRONG_INITWT IDU 93 2000F019 IDU_WRONG_INITRJ IDU 94 2000F01A IDU_WRONG_INIT_MAN_RECOG IDU 94 2000F01B IDU_HYB_DLL_LOAD_FAILED IDU 94 2000F01C IDU_WRONG_INIT_LED IDU 94 2000F01D IDU_SEL_DLL_LOAD_FAILED IDU 94 2000F01E IDU_CIT_DLL_LOAD_FAILED IDU 94 2000F020 IDU_INVALID_FRMFILE IDU 95 2000F021 IDU_WRONG_INIT_LOADER_CTL IDU 95 2000F022 IDU_TRA_DLL_LOAD_FAILED IDU 95 2000F023 IDU_WRONG_TRANSACTION_ACTIVE IDU 95 2000F024 IDU_WRONG_TRANSACTION_TRIGGER IDU 95 2000F025 IDU_WRONG_ERROE_MAPPING IDU 95 2000F026 IDU_WRONG_CHIPMODE IDU 96 2000F027 IDU_WRONG_ENTRY_HANDLING IDU 96 2000F028 IDU_SWI_DLL_LOAD_FAILED IDU 96 2000F029 IDU_EDS_DLL_LOAD_FAILED IDU 96 2000F02A IDU_EDM_DLL_LOAD_FAILED IDU 96 2000F02B IDU_ICM_DLL_LOAD_FAILED IDU 96 2000F02C IDU_WRONG_SAMMODE IDU 97 2000F02D IDU_WRONG_SAM IDU 97 2000F02E IDU_V2X_DLL_LOAD_FAILED IDU 97 2000F030 IDU_WRONG_INIT_ADDITION_UNIT IDU 97 2000F031 IDU_MCT_DLL_LOAD_FAILED IDU 97 2000F032 IDU_WRONG_CARD_GRIP_LENGTH IDU 97 2000FA02 OPL_INIT_ERROR OPL 133 2000FA03 OPL_INITRUN OPL 133 2000FA04 OPL_MAXBUFFER_EXCEEDED OPL 133 2000FA05 OPL_INVALID_PARAMETER OPL 133 2000FA06 OPL_INVALID_PSZREPLACE OPL 134 2000FA07 OPL_INVALID_MODE OPL 134 2000FA08 OPL_RUNNING_SCRIPT OPL 134 2000FA0A OPL_NO_CURSOR_POS_SAVED OPL 134 2000FA0B OPL_INVALID_RESPONSE OPL 134 2000FA30 OPL_GRAPHIC_FILE_OPEN OPL 134 2000FA31 OPL_GRAPHIC_FILE_READ OPL 135 2000FA32 OPL_GRAPHIC_FILE_SETPOS OPL 135 2000FA33 OPL_GRAPHIC_FILE_CLOSE OPL 135 2000FA34 OPL_GRAPHIC_INVALID_TYPE OPL 135 2000FA35 OPL_GRAPHIC_INVALID_RESOLUTION OPL 135 2000FA36 OPL_GRAPHIC_INVALID_COLOR OPL 135 2000FA37 OPL_GRAPHIC_INVALID_COMPRESSION OPL 136 2000FA38 OPL_GRAPHIC_INVALID_SIZE OPL 136

Page 711: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 703

StCode StWarn Define Device Page

2000FA39 OPL_GRAPHIC_PATH_TOO_LONG OPL 136 2000FA40 OPL_SCRIPT_FILE_OPEN OPL 136 2000FA41 OPL_SCRIPT_FILE_READ OPL 136 2000FA42 OPL_SCRIPT_FILE_CLOSE OPL 136 2000FA43 OPL_SCRIPT_LINE_TOO_LONG OPL 137 2000FA44 OPL_SCRIPT_TOO_MANY_COMMANDS OPL 137 2000FA45 OPL_SCRIPT_INVALID_COMMAND OPL 137 2000FA46 OPL_SCRIPT_INVALID_SYNTAX OPL 137 2000FA47 OPL_SCRIPT_INVALID_PARA OPL 137 2000FA48 OPL_SCRIPT_MISSING_PARA OPL 137 2000FA49 OPL_SCRIPT_MISSING_REPEAT OPL 138 2000FA4A OPL_SCRIPT_MISSING_ENDREP OPL 138 2000FA4B OPL_SCRIPT_NESTED_LOOP OPL 138 2000FA4C OPL_SCRIPT_EMPTY_LOOP OPL 138 2000FE06 COMM_INVALID_PROTOCOL COMM 31 2000FE07 COMM_WRITE_CANCELED COMM 31 2000FE08 COMM_WRITE_TIMEOUT COMM 31 2000FE09 COMM_READ_TIMEOUT COMM 32 2000FE09 I1394_READ_TIMEOUT I1394 43 2000FE09 USB_READ_TIMEOUT USB 64 2000FE0A COMM_READ_CANCELED COMM 32 2000FE0A I1394_READ_CANCELED I1394 43 2000FE0A USB_READ_CANCELED USB 64 2000FE0B COMM_PARITY_ERROR COMM 32 2000FE0C COMM_GENERAL_FAILURE COMM 32 2000FE0F COMM_PROTOCOL_VIOLATION COMM 32 2000FE13 COMM_CHAN_NOT_INITIALIZED COMM 33 2000FE14 COMM_ACCESS_DENIED COMM 33 2000FE16 COMM_BREAK COMM 33 2000FE7A COMM_OVERRUN_ERROR COMM 33 2000FE7B COMM_FRAMING_ERROR COMM 33 2000FE85 COMM_DRIVER_OPEN_FAILED COMM 34 2000FE89 BCD_INVALID_PTXDATA BCD 603 2000FE89 COMM_INVALID_PTXDATA COMM 34 2000FE89 I1394_INVALID_PDATA I1394 43 2000FE89 USB_INVALID_PDATA USB 64 2000FE8B COMM_INVALID_OPEN_SPEC COMM 34 2000FE8C COMM_NO_STX COMM 34 2000FE8D COMM_NO_ETX COMM 34 2000FE8E COMM_INVALID_BLK_LEN COMM 35 2000FE8F COMM_INVALID_BLK_ID COMM 35 2000FE90 COMM_INVALID_DEV_ID COMM 35 2000FE91 COMM_INVALID_COMMAND COMM 35 2000FE92 BCD_INVALID_ACK_TYPE BCD 603 2000FE92 COMM_INVALID_ACK_TYPE COMM 36 2000FE93 BCD_MAX_TX_RETRIES BCD 603 2000FE93 COMM_MAX_TX_RETRIES COMM 36 2000FE94 COMM_MAX_RX_RETRIES COMM 36

Page 712: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

704 June 2004

StCode StWarn Define Device Page

2000FE95 BCD_PROTOCOL_TX_TIMEOUT BCD 603 2000FE95 COMM_PROTOCOL_TX_TIMEOUT COMM 36 2000FE96 BCD_PROTOCOL_RX_TIMEOUT BCD 603 2000FE96 COMM_PROTOCOL_RX_TIMEOUT COMM 37 2000FE97 COMM_PROTOCOL_POLL_TIMEOUT COMM 37 2000FE98 COMM_PROTOCOL_CANCELED COMM 37 2000FE9C COMM_INVALID_TXDATA_LEN COMM 37 2000FE9C I1394_INVALID_DATASIZE I1394 43 2000FE9C USB_INVALID_DATASIZE USB 65 2000FE9D COMM_CSCISO_DLL_NOT_FOUND COMM 37 2000FE9D I1394_TS_DLL_NOT_FOUND I1394 44 2000FE9E COMM_CSCISO_DLL_OPEN_FAILED COMM 38 2000FE9E I1394_TS_DLL_OPEN_FAILED I1394 44 2000FE9F COMM_CSCUSB_DLL_NOT_FOUND COMM 38 2000FE9F I1394_UB_DLL_NOT_FOUND I1394 44 2000FEA0 COMM_CSCUSB_DLL_OPEN_FAILED COMM 38 2000FEA0 I1394_UB_DLL_OPEN_FAILED I1394 44 2000FEB0 COMM_INVALID_DRIVER_CONF COMM 38 2000FEE0 COMM_P2_TX_NO_RESP_ON_ENQ COMM 38 2000FEE1 COMM_P2_TX_INVALID_RESP_ON_ENQ COMM 38 2000FEE2 COMM_P2_TX_NAK_RECEIVED COMM 39 2000FEE3 COMM_P2_TX_NO_VALID_RESP_ON_TEXT COMM 39 2000FEE4 COMM_P2_TX_MAX_RETRIES COMM 39 2000FEE5 COMM_P2_TX_ABORTED COMM 39 2000FEE6 COMM_P2_RX_CMD_TIMEOUT COMM 40 2000FEE7 COMM_P2_RX_ISO_TIMEOUT COMM 40 2000FEE8 COMM_P2_RX_INVALID_HEADER COMM 40 2000FEE9 COMM_P2_RX_INVALID_DEVICE_ID COMM 40 2000FEEA COMM_P2_RX_INVALID_CMD_ID COMM 41 2000FEEB COMM_P2_RX_INVALID_CMD_SPEC COMM 41 2000FEEC COMM_P2_RX_CRC_ERROR COMM 41 2000FEED COMM_P2_NO_CMD_ACTIVE COMM 41 2000FEEF COMM_P2_CMD_NOT_CANCABLE COMM 41 2000FEF0 COMM_P2_CMD_STILL_ACTIVE COMM 42 2000FEF1 COMM_P2_CMD_CANCELLED COMM 42 2000FEF2 COMM_P2_CANCEL_STILL_ACTIVE COMM 42 2000FEF3 COMM_P2_CANCEL_NOT_SUCCESSFUL COMM 42 2000FEF4 COMM_P2_TX_CANCEL_TIMEOUT COMM 42 2000FEF5 COMM_P2_SYNCHRONISATION_ERROR COMM 42 2000FFFE P36_ERR_OVERFLOW P36 584 2000FFFE P36_WARN_OVERFLOW P36 585 2000FFFF CNG_EXT_NO_EXTENDED_ERROR CNG_EXT 580 2000FFFF P36_ERR_CHKSUM1 P36 584 2000FFFF P36_WARN_CHKSUM1 P36 585 20010400 RECO_LGK_ERROR_04 RECO 364 20010500 RECO_LGK_ERROR_05 RECO 364 20010800 RECO_LGK_ERROR_08 RECO 364 20010900 RECO_LGK_ERROR_09 RECO 364

Page 713: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 705

StCode StWarn Define Device Page

20010A00 RECO_LGK_ERROR_0A RECO 365 20010B00 RECO_LGK_ERROR_0B RECO 365 20010C00 RECO_LGK_ERROR_0C RECO 365 20010D00 RECO_LGK_ERROR_0D RECO 365 20010E00 RECO_LGK_ERROR_0E RECO 366 20010F00 RECO_LGK_ERROR_0F RECO 366 20011000 RECO_LGK_ERROR_10 RECO 366 20011100 RECO_LGK_ERROR_11 RECO 366 20011200 RECO_LGK_ERROR_12 RECO 367 20011300 RECO_LGK_ERROR_13 RECO 367 20011400 RECO_LGK_ERROR_14 RECO 367 20011500 RECO_LGK_ERROR_15 RECO 367 20011600 RECO_LGK_ERROR_16 RECO 368 20011700 RECO_LGK_ERROR_17 RECO 368 20011800 RECO_LGK_ERROR_18 RECO 368 20011900 RECO_LGK_ERROR_19 RECO 368 20011A00 RECO_LGK_ERROR_1A RECO 369 20011B00 RECO_LGK_ERROR_1B RECO 369 20011C00 RECO_LGK_ERROR_1C RECO 369 20011D00 RECO_LGK_ERROR_1D RECO 369 20011E00 RECO_LGK_ERROR_1E RECO 370 20011F00 RECO_LGK_ERROR_1F RECO 370 20012000 RECO_LGK_ERROR_20 RECO 370 20012100 RECO_LGK_ERROR_21 RECO 370 20012200 RECO_LGK_ERROR_22 RECO 371 20012300 RECO_LGK_ERROR_23 RECO 371 20012400 RECO_LGK_ERROR_24 RECO 371 20012500 RECO_LGK_ERROR_25 RECO 371 20012600 RECO_LGK_ERROR_26 RECO 372 20012700 RECO_LGK_ERROR_27 RECO 372 20012800 RECO_LGK_ERROR_28 RECO 372 20012900 RECO_LGK_ERROR_29 RECO 372 20012A00 RECO_LGK_ERROR_2A RECO 373 20012B00 RECO_LGK_ERROR_2B RECO 373 20012C00 RECO_LGK_ERROR_2C RECO 373 20012D00 RECO_LGK_ERROR_2D RECO 373 20012E00 RECO_LGK_ERROR_2E RECO 374 20012F00 RECO_LGK_ERROR_2F RECO 374 20013000 RECO_LGK_ERROR_30 RECO 374 20013200 RECO_LGK_ERROR_32 RECO 374 20013C00 RECO_LGK_ERROR_3C RECO 375 20013D00 RECO_LGK_ERROR_3D RECO 375 20014600 RECO_LGK_ERROR_46 RECO 375 20014700 RECO_LGK_ERROR_47 RECO 375 20014800 RECO_LGK_ERROR_48 RECO 376 20014900 RECO_LGK_ERROR_49 RECO 376 20015000 RECO_LGK_ERROR_50 RECO 376 20015200 RECO_LGK_ERROR_52 RECO 376

Page 714: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

706 June 2004

StCode StWarn Define Device Page

20015400 RECO_LGK_ERROR_54 RECO 377 20015500 RECO_LGK_ERROR_55 RECO 377 20015700 RECO_LGK_ERROR_57 RECO 377 20015900 RECO_LGK_ERROR_59 RECO 377 20015A00 RECO_LGK_ERROR_5A RECO 378 20015C00 RECO_LGK_ERROR_5C RECO 378 200250F2 RECO_ERROR_50_F2 RECO 378 200250F3 RECO_ERROR_50_F3 RECO 378 200250F7 RECO_ERROR_50_F7 RECO 379 20025101 RECO_ERROR_51_01 RECO 379 20025102 RECO_ERROR_51_02 RECO 379 20025103 RECO_ERROR_51_03 RECO 379 20025105 RECO_ERROR_51_05 RECO 380 20025108 RECO_ERROR_51_08 RECO 380 200251F1 RECO_ERROR_51_F1 RECO 380 200251F2 RECO_ERROR_51_F2 RECO 380 200251F3 RECO_ERROR_51_F3 RECO 381 200251F4 RECO_ERROR_51_F4 RECO 381 200251F5 RECO_ERROR_51_F5 RECO 381 20025201 RECO_ERROR_52_01 RECO 381 20025211 RECO_ERROR_52_11 RECO 382 20025212 RECO_ERROR_52_12 RECO 382 20025213 RECO_ERROR_52_13 RECO 382 20025214 RECO_ERROR_52_14 RECO 382 20025215 RECO_ERROR_52_15 RECO 383 20025218 RECO_ERROR_52_18 RECO 383 20025219 RECO_ERROR_52_19 RECO 383 20025302 RECO_ERROR_53_02 RECO 383 20025303 RECO_ERROR_53_03 RECO 384 20025304 RECO_ERROR_53_04 RECO 384 20025305 RECO_ERROR_53_05 RECO 384 20025306 RECO_ERROR_53_06 RECO 384 20025307 RECO_ERROR_53_07 RECO 385 20025308 RECO_ERROR_53_08 RECO 385 20025309 RECO_ERROR_53_09 RECO 385 2002530A RECO_ERROR_53_0A RECO 385 2002530D RECO_ERROR_53_0D RECO 386 20025311 RECO_ERROR_53_11 RECO 386 20025312 RECO_ERROR_53_12 RECO 386 20025313 RECO_ERROR_53_13 RECO 386 20025314 RECO_ERROR_53_14 RECO 387 20025315 RECO_ERROR_53_15 RECO 387 20025501 RECO_ERROR_55_01 RECO 387 20025502 RECO_ERROR_55_02 RECO 387 20025503 RECO_ERROR_55_03 RECO 388 20025504 RECO_ERROR_55_04 RECO 388 20025505 RECO_ERROR_55_05 RECO 388 20025506 RECO_ERROR_55_06 RECO 388

Page 715: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 707

StCode StWarn Define Device Page

20025507 RECO_ERROR_55_07 RECO 389 20025508 RECO_ERROR_55_08 RECO 389 20025511 RECO_ERROR_55_11 RECO 389 20025512 RECO_ERROR_55_12 RECO 389 20025513 RECO_ERROR_55_13 RECO 390 20025514 RECO_ERROR_55_14 RECO 390 20025515 RECO_ERROR_55_15 RECO 390 20025519 RECO_ERROR_55_19 RECO 390 2002551A RECO_ERROR_55_1A RECO 391 2002551B RECO_ERROR_55_1B RECO 391 20025521 RECO_ERROR_55_21 RECO 391 20025522 RECO_ERROR_55_22 RECO 391 20025523 RECO_ERROR_55_23 RECO 392 20025524 RECO_ERROR_55_24 RECO 392 20025526 RECO_ERROR_55_26 RECO 392 20025529 RECO_ERROR_55_29 RECO 392 2002552A RECO_ERROR_55_2A RECO 393 2002552C RECO_ERROR_55_2C RECO 393 2002552D RECO_ERROR_55_2D RECO 393 20025531 RECO_ERROR_55_31 RECO 393 20025532 RECO_ERROR_55_32 RECO 394 20025533 RECO_ERROR_55_33 RECO 394 20025534 RECO_ERROR_55_34 RECO 394 20025536 RECO_ERROR_55_36 RECO 394 20025539 RECO_ERROR_55_39 RECO 395 2002553A RECO_ERROR_55_3A RECO 395 20025541 RECO_ERROR_55_41 RECO 395 20025542 RECO_ERROR_55_42 RECO 395 20025543 RECO_ERROR_55_43 RECO 396 20025544 RECO_ERROR_55_44 RECO 396 20025545 RECO_ERROR_55_45 RECO 396 20025546 RECO_ERROR_55_46 RECO 396 20025549 RECO_ERROR_55_49 RECO 397 2002554A RECO_ERROR_55_4A RECO 397 20025551 RECO_ERROR_55_51 RECO 397 20025552 RECO_ERROR_55_52 RECO 397 20025553 RECO_ERROR_55_53 RECO 398 20025554 RECO_ERROR_55_54 RECO 398 20025555 RECO_ERROR_55_55 RECO 398 20025556 RECO_ERROR_55_56 RECO 398 20025559 RECO_ERROR_55_59 RECO 399 200255F1 RECO_ERROR_55_F1 RECO 399 200255F2 RECO_ERROR_55_F2 RECO 399 200255F3 RECO_ERROR_55_F3 RECO 399 200255F4 RECO_ERROR_55_F4 RECO 400 20025F00 RECO_ERROR_5F_00 RECO 400 20025F01 RECO_ERROR_5F_01 RECO 400 20025F02 RECO_ERROR_5F_02 RECO 400

Page 716: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

708 June 2004

StCode StWarn Define Device Page

20025F03 RECO_ERROR_5F_03 RECO 401 20025F04 RECO_ERROR_5F_04 RECO 401 20025F05 RECO_ERROR_5F_05 RECO 401 20025F06 RECO_ERROR_5F_06 RECO 401 20025F07 RECO_ERROR_5F_07 RECO 402 20025F12 RECO_ERROR_5F_12 RECO 402 20025F13 RECO_ERROR_5F_13 RECO 402 20025F20 RECO_ERROR_5F_20 RECO 402 20025F21 RECO_ERROR_5F_21 RECO 403 20025F22 RECO_ERROR_5F_22 RECO 403 20025F23 RECO_ERROR_5F_23 RECO 403 20025F24 RECO_ERROR_5F_24 RECO 403 20025F25 RECO_ERROR_5F_25 RECO 404 20025F26 RECO_ERROR_5F_26 RECO 404 20025F27 RECO_ERROR_5F_27 RECO 404 20025F28 RECO_ERROR_5F_28 RECO 404 20025F29 RECO_ERROR_5F_29 RECO 405 20025F2A RECO_ERROR_5F_2A RECO 405 20025F2C RECO_ERROR_5F_2C RECO 405 20025F2D RECO_ERROR_5F_2D RECO 405 20025F2E RECO_ERROR_5F_2E RECO 406 20027500 RECO_ERROR_75_00 RECO 406 20027501 RECO_ERROR_75_01 RECO 406 20027502 RECO_ERROR_75_02 RECO 406 20027503 RECO_ERROR_75_03 RECO 407 20027505 RECO_ERROR_75_05 RECO 407 20027506 RECO_ERROR_75_06 RECO 407 2002750A RECO_ERROR_75_0A RECO 407 2002750C RECO_ERROR_75_0C RECO 408 2002750D RECO_ERROR_75_0D RECO 408 2002750E RECO_ERROR_75_0E RECO 408 2002750F RECO_ERROR_75_0F RECO 408 20027512 RECO_ERROR_75_12 RECO 409 20027514 RECO_ERROR_75_14 RECO 409 20027515 RECO_ERROR_75_15 RECO 409 20027521 RECO_ERROR_75_21 RECO 409 20027523 RECO_ERROR_75_23 RECO 410 20027525 RECO_ERROR_75_25 RECO 410 20027528 RECO_ERROR_75_28 RECO 410 20027529 RECO_ERROR_75_29 RECO 410 2002A101 RECO_ERROR_A1_01 RECO 411 2002A102 RECO_ERROR_A1_02 RECO 411 2002A501 RECO_ERROR_A5_01 RECO 411 20080001 SCAN_RU_ILL_CMD SCAN 240 20080002 SCAN_RU_ACCESS_ERROR SCAN 240 20080003 SCAN_RU_BOARD_MISSING SCAN 240 20080004 SCAN_RU_INVALID_CMD_FORMAT SCAN 240 20080005 SCAN_RU_DATA_AVAILABLE SCAN 241

Page 717: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 709

StCode StWarn Define Device Page

20080006 SCAN_RU_NOT_READY SCAN 241 20080007 SCAN_RU_CS_ERROR SCAN 241 20080008 SCAN_RU_CS_TIMEOUT SCAN 241 20080009 SCAN_RU_COMM_TIMEOUT SCAN 242 2008000A SCAN_RU_READ_TIMEOUT SCAN 242 2008000B SCAN_RU_INVALID_OUTLEN SCAN 242 2008000C SCAN_RU_INVALID_PTR SCAN 242 2008000D SCAN_RU_NO_STS SCAN 242 2008000E SCAN_RU_DMA_TIMEOUT SCAN 243 200A0020 I1394_ERROR_TIMEOUT I1394 44 200A0100 I1394_ERROR_NO_MEMORY I1394 45 200A0210 I1394_ERROR_INVALID_DEVICE_STATE I1394 45 200A0300 I1394_ERROR_INVALID_PARAMETER I1394 45 200A0305 I1394_ERROR_INVALID_BUFFER_SIZE I1394 45 200A8001 I1394_ERROR_DEVICE_NOT_FOUND I1394 46 200A8010 I1394_ERROR_NO_SUCH_DEV_INSTANCE I1394 46 200B0100 I1394_ERROR_ABORTED I1394 46 200B0200 I1394_ERROR_ADAPTER I1394 46 200B0250 I1394_ERROR_ALREADY_OPEN I1394 47 200B0270 I1394_ERROR_BR_LIMIT I1394 47 200B0300 I1394_ERROR_BUS_RESET I1394 47 200B0350 I1394_ERROR_CONFLICT I1394 47 200B0370 I1394_ERROR_CRC I1394 48 200B0400 I1394_CRITICAL_ADAPTER_ERROR I1394 48 200B0500 I1394_ERROR_DEVICE_BUSY I1394 48 200B0572 I1394_ERROR_DMA I1394 48 200B0600 I1394_DRIVER_INTERNAL_ERROR I1394 49 200B0639 I1394_ERROR_DUPLICATE_CHANNEL I1394 49 200B0645 I1394_ERROR_FIFO_OVERRUN I1394 49 200B0658 I1394_ERROR_FIFO_UNDERRUN I1394 49 200B0671 I1394_ERROR_GAP_COUNT I1394 50 200B06B2 I1394_ERROR_INCORRECT_RESPONSE I1394 50 200B0700 I1394_ERROR_INSUFFICIENT_RESOURCES I1394 50 200B0900 I1394_ERROR_INVALID_CHANNEL_TYPE I1394 50 200B0A00 I1394_ERROR_INVALID_CHANNEL_STATE I1394 51 200B0C00 I1394_ERROR_INVALID_HANDLE I1394 51 200B0D00 I1394_ERROR_INVALID_ISOCHRONOUS_BUFFERS I1394 51 200B0D47 I1394_ERROR_INVALID_OFFSET I1394 51 200B0F00 I1394_ERROR_INVALID_REQUEST I1394 52 200B0F50 I1394_ERROR_INVALID_RESPONSE I1394 52 200B0F73 I1394_ERROR_LOCK_FAILED I1394 52 200B1070 I1394_ERROR_NOT_FOUND I1394 52 200B1100 I1394_ERROR_NOT_IMPLEMENTED I1394 53 200B1200 I1394_ERROR_NOTSUPPORTED I1394 53 200B1300 I1394_ERROR_PENDING I1394 53 200B1313 I1394_ERROR_SELFID I1394 53 200B132A I1394_ERROR_SIZE_LIMITATION I1394 54 200B1350 I1394_ERROR_SPEED_LIMITATION I1394 54

Page 718: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

710 June 2004

StCode StWarn Define Device Page

200B1409 I1394_ERROR_TOPOLOGY I1394 54 200B1433 I1394_ERROR_TRANSACTION_FAILED I1394 54 200B1450 I1394_ERROR_UNSOLICITED_RESPONSE I1394 55 200B1500 I1394_ERROR_UNSUCCESSFUL I1394 55 200E0001 I1394_FAILED I1394 55 200E0010 I1394_ERROR_NOT_SUPPORTED I1394 55 200E0011 I1394_ERROR_VERSION_MISMATCH I1394 56 200E0030 I1394_ERROR_REJECTED I1394 56 200E0110 I1394_ERROR_POOL_EMPTY I1394 56 200E0200 I1394_ERROR_DEVICE_NOT_PRESENT I1394 56 200E0220 I1394_ERROR_INVALID_POWER_STATE I1394 56 200E0280 I1394_ERROR_POWER_DOWN I1394 57 200E0302 I1394_ERROR_INVALID_IOCTL I1394 57 200E0304 I1394_ERROR_INVALID_BYTE_COUNT I1394 57 200E0310 I1394_ERROR_INVALID_INBUFFER I1394 57 200E0320 I1394_ERROR_INVALID_OUTBUFFER I1394 58 200E0340 I1394_ERROR_BOUND_TO_THIS I1394 58 200E0341 I1394_ERROR_BOUND_TO_OTHER I1394 58 200E0342 I1394_ERROR_NOT_BOUND I1394 58 200E0350 I1394_ERROR_BUS_RESET_OCCURED I1394 59 200E0351 I1394_ERROR_INVALID_GEN_COUNT I1394 59 200E0400 I1394_ERROR_INVALID_CONFIG_TYPE I1394 59 200E0401 I1394_ERROR_INVALID_INFO_TYPE I1394 59 200E0402 I1394_ERROR_INVALID_PROP_TYPE I1394 60 200E0403 I1394_ERROR_INVALID_LOCK_TYPE I1394 60 200E0404 I1394_ERROR_INVALID_SPEED I1394 60 200E8002 I1394_ERROR_DEVICE_NOT_OPEN I1394 60 200E8003 I1394_ERROR_WAIT_TIMEOUT I1394 61 200E8008 I1394_ERROR_INVALID_FUNCTION_PARAM I1394 61 200E8020 I1394_ERROR_MEM_ALLOC_FAILED I1394 61 28000001 CDM_WARNING_GENERAL CDM_FRM 466 28000001 PRT_STACK_END ND94 261 28000001 PRT_STACK_END ND97 269 28000001 PRT_WARN_BON_PAPER_LOW ND71 251 28000001 PRT_WARN_BON_PAPER_LOW ND79 256 28000001 PRT_WARN_BON_PAPER_LOW ND99 280 28000001 RJ03_WARN_BON_PAPER_LOW RJ03 327 28000001 TH21_WARN_BON_PAPER_LOW TH21 285 28000002 CDM_WARNING_LB CDM_FRM 466 28000002 PRT_WARN_JOURNAL_PAPER_LOW ND71 251 28000002 PRT_WEEKEND_LIMIT ND94 261 28000002 PRT_WEEKEND_LIMIT ND97 269 28000003 CDM_WARNING_THRESHOLD_VALUE CDM_FRM 466 28000003 PRT_TENTH_DOCUMENT ND94 261 28000003 PRT_TENTH_DOCUMENT ND97 270 28000003 PRT_WARN_BON_SENSOR ND71 251 28000003 PRT_WARN_BON_SENSOR ND79 256 28000004 CDM_WARNING_EEPROM_MS CDM_FRM 466

Page 719: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 711

StCode StWarn Define Device Page

28000004 PRT_PRE_WARN_REJECT ND94 261 28000004 PRT_PRE_WARN_REJECT ND97 270 28000004 PRT_WARN_LAST_BON ND79 256 28000005 CDM_WARNING_EEPROM_LBAMP CDM_FRM 466 28000005 PRT_CONTRAST_OK ND97 270 28000006 CDM_WARNING_RETRACT CDM_FRM 467 28000006 PRT_WEAK_CONTRAST ND97 270 28000007 CDM_WARNING_MONEY CDM_FRM 467 28000007 PRT_NO_SUFFICIENT_CONTRAST ND97 270 28000008 PRT_STACK_END_LANE2 ND97 270 28000009 PRT_WEEKEND_LIMIT_LANE2 ND97 271 2800000A PRT_CHECKSUM_MEMORY ND97 271 28000100 CDM_INVALID_TRANSPORT CDM_FRM 415 28000200 CDM_TRANSP_DIR_NOT_AVAIL CDM_FRM 415 28000300 CDM_REJ_CAS_FULL CDM_FRM 415 28000400 CDM_PLAUSIBILITY_ERROR CDM_FRM 415 28001000 CDM_INVALID_BLK_LEN CDM_FRM 415 28001100 CDM_INVALID_DEV_ID CDM_FRM 416 28001200 CDM_INVALID_COMMAND CDM_FRM 416 28001300 CDM_INVALID_COMMAND_LEN CDM_FRM 416 28001400 CDM_SUBMODUL_NOT_AVAIL CDM_FRM 416 28001500 CDM_INVALID_STATUS_SPEC CDM_FRM 416 28001600 CDM_INVALID_AREA CDM_FRM 417 28001700 CDM_INVALID_BLK_LEN_CHAR CDM_FRM 417 28001800 CDM_INVALID_TRANSPORT_SPEC CDM_FRM 417 28001900 CDM_INVALID_SEPARATOR CDM_FRM 417 28001A00 CDM_BUSY CDM_FRM 417 28001B00 CDM_CAS_PROT_ERROR_AREA_N CDM_FRM 417 28001C00 CDM_PUT_NOT_AVAIL CDM_FRM 418 28001D00 CDM_INVALID_SPEC_LBAMP CDM_FRM 418 28002000 CDM_VALUE_NOT_AVAIL_R CDM_FRM 418 28002100 CDM_LB_MS_TIMEOUT CDM_FRM 418 28002200 CDM_LB_L1_TIMEOUT CDM_FRM 419 28002300 CDM_LB_COL_TRAY_TIMEOUT CDM_FRM 419 28002400 CDM_LB_REJ_TIMEOUT CDM_FRM 419 28002500 CDM_SINGLE_REJ_ERROR CDM_FRM 419 28002600 CDM_DOUPLE_DISPENSING CDM_FRM 420 28002700 CDM_DMODUL_ERROR CDM_FRM 420 28002800 CDM_VALUE_NOT_AVAIL_A CDM_FRM 421 28002900 CDM_CAS_INVALID_CURRENCY CDM_FRM 421 28002A00 CDM_INVALID_NR_NOTES CDM_FRM 421 28002B00 CDM_ERROR_LBAMP CDM_FRM 422 28002C00 CDM_INVALID_CONFIG CDM_FRM 422 28002D00 CDM_LB_L17_L25_ERROR CDM_FRM 422 28003100 CDM_DMODUL_1_TIMEOUT CDM_FRM 422 28003200 CDM_DMODUL_2_TIMEOUT CDM_FRM 423 28003300 CDM_DMODUL_3_TIMEOUT CDM_FRM 423 28003400 CDM_DMODUL_4_TIMEOUT CDM_FRM 423

Page 720: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

712 June 2004

StCode StWarn Define Device Page

28003500 CDM_DMODUL_5_TIMEOUT CDM_FRM 424 28005000 CDM_LB_L17_CONVERED CDM_FRM 424 28005100 CDM_LB_L18_OR_L22_CONVERED CDM_FRM 424 28005110 CDM_R_LB_L18_COVERED CDM_FRM 425 28005111 CDM_R_LB_L18_RETRACT_COVERED CDM_FRM 425 28005118 CDM_R_LB_L18_NOT_REACHED CDM_FRM 425 28005119 CDM_R_LB_L18_RETR_NOT_REACHED CDM_FRM 426 28005200 CDM_LB_L19_COVERED CDM_FRM 426 28005210 CDM_R_LB_L19_COVERED CDM_FRM 426 28005211 CDM_R_LB_L19_RETRACT_COVERED CDM_FRM 427 28005218 CDM_R_LB_L19_NOT_REACHED CDM_FRM 427 28005219 CDM_R_LB_L19_RETR_NOT_REACHED CDM_FRM 427 28005300 CDM_LB_L20_COVERED CDM_FRM 428 28005400 CDM_LB_L21_COVERED CDM_FRM 428 28005410 CDM_R_LB_L21_COVERED CDM_FRM 428 28005418 CDM_R_LB_L21_NOT_REACHED CDM_FRM 429 28005500 CDM_LB_L22_COVERED CDM_FRM 429 28005510 CDM_R_LB_L22_COVERED CDM_FRM 429 28005511 CDM_R_LB_L22_RETRACT_COVERED CDM_FRM 430 28005518 CDM_R_LB_L22_NOT_REACHED CDM_FRM 430 28005519 CDM_R_LB_L22_RETR_NOT_REACHED CDM_FRM 430 28005610 CDM_R_LB_L23_COVERED CDM_FRM 431 28005611 CDM_R_LB_L23_RETRACT_CONVERED CDM_FRM 431 28005618 CDM_R_LB_L23_NOT_REACHED CDM_FRM 431 28005619 CDM_R_LB_L23_RETR_NOT_REACHED CDM_FRM 432 28005700 CDM_SWIVEL_ARM_ERROR_DOWN CDM_FRM 432 28005710 CDM_R_SWIVEL_ARM_ERROR_DOWN CDM_FRM 432 28005800 CDM_SWIVEL_ARM_ERROR_UP CDM_FRM 433 28005810 CDM_R_SWIVEL_ARM_ERROR_UP CDM_FRM 433 28005B00 CDM_CASH_SLOT_ERROR_DOWN CDM_FRM 433 28005B10 CDM_R_SHUTTER_CLOSE_ERROR CDM_FRM 434 28005B11 CDM_R_SHUTTER_RETR_CLOSE_ERR1 CDM_FRM 434 28005B12 CDM_R_SHUTTER_RETR_CLOSE_ERR2 CDM_FRM 434 28005B13 CDM_R_SHUTTER_CLOSE_ERROR2 CDM_FRM 435 28005C00 CDM_CASH_SLOT_ERROR_UP CDM_FRM 435 28005C10 CDM_R_SHUTTER_OPEN_ERROR CDM_FRM 435 28005C11 CDM_R_SHUTTER_RETR_OPEN_ERR1 CDM_FRM 436 28005C12 CDM_R_SHUTTER_RETR_OPEN_ERR2 CDM_FRM 436 28005C13 CDM_R_SHUTTER_OPEN_ERROR2 CDM_FRM 436 28005D00 CDM_FEED_JAM_LB_L17 CDM_FRM 437 28005D10 CDM_R_MOTOR2_NO_CLOCKS CDM_FRM 437 28005D11 CDM_R_MOTOR2_RETR_NO_CLOCKS CDM_FRM 437 28005F10 CDM_R_LB_L25_COVERED CDM_FRM 438 28005F11 CDM_R_LB_L25_RETRACT_COVERED CDM_FRM 438 28005F18 CDM_R_LB_L25_NOT_REACHED CDM_FRM 438 28005F19 CDM_R_LB_L25_RETR_NOT_REACHED CDM_FRM 439 28006300 CDM_FEED_JAM_LB_L21 CDM_FRM 439 28006310 CDM_R_LB_L21_REJECT_COVERED CDM_FRM 439

Page 721: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 713

StCode StWarn Define Device Page

28006311 CDM_R_LB_L21_RETRACT_COVERED CDM_FRM 440 28006318 CDM_R_LB_L21_REJECT_NOT_REACHED CDM_FRM 440 28006319 CDM_R_LB_L21_RETR_NOT_REACHED CDM_FRM 440 28007001 RKL_ERR_PARAMETER RKL 169 28007001 SIBS_ERR_DATA_LEN_INSUF SIBS 181 28007002 RKL_ERR_DATA_LEN_INSUF RKL 170 28007002 SIBS_ERR_DATA_INV SIBS 181 28007003 RKL_ERR_SIGN_LEN_INV RKL 170 28007003 SIBS_ERR_FDM_ACC SIBS 181 28007010 CDM_R_LB_L26_COVERED CDM_FRM 441 28007010 RKL_ERR_TOKEN_UNKNOWN RKL 170 28007011 CDM_R_LB_L26_RETRACT_COVERED CDM_FRM 441 28007011 RKL_ERR_TOKEN_ILLEGAL RKL 170 28007012 CDM_R_LB_L26_UE_COVERED CDM_FRM 441 28007013 CDM_R_LB_L26_RETRACT_UE_COVERED CDM_FRM 442 28007018 CDM_R_LB_L26_NOT_REACHED CDM_FRM 442 28007019 CDM_R_LB_L26_BEFORE_RETR_FREE CDM_FRM 442 28007020 RKL_ERR_FORMAT_ASN1 RKL 170 28007021 RKL_ERR_FORMAT_PKCS RKL 170 2800702D SIBS_ERR_FORMAT_HEX SIBS 181 28007070 RKL_ERR_SIGN_INV RKL 171 28007071 RKL_ERR_SECURE_RND RKL 171 28007080 ZKA_FRM_KEY_NOT_VALID ZKA 206 28007082 ZKA_FRM_KEY_NOT_LOADED ZKA 206 28007083 ZKA_FRM_NO_KGK ZKA 206 28007090 RKL_ERR_MEMORY_OVFL RKL 171 28007091 RKL_ERR_KEYRAM_OVFL RKL 171 280070A1 ERR_STATUS_ILLEGAL RKL 171 280070A1 SIBS_ERR_CMD_STAGE_INV SIBS 182 280070A2 SIBS_ERR_CACHE_MISS SIBS 182 280070A2 ZKA_FRM_PIN_RETRIES ZKA 207 280070A3 SIBS_ERR_TEXT_LEN_INSUF SIBS 182 280070A3 ZKA_FRM_PIN_WRONG_L ZKA 207 280070A4 SIBS_ERR_PIN_BLK_TYPE_INV SIBS 182 280070A4 ZKA_FRM_LOAD_NOT_POSIBLE ZKA 207 280070A5 SIBS_ERR_MAC_INV SIBS 182 280070A6 SIBS_ERR_ACQ_BLK_FULL SIBS 182 280070A7 SIBS_ERR_ACQ_KCV_INV SIBS 183 280070A8 SIBS_KEY_PAR_INV SIBS 183 280070A9 SIBS_ERR_ACQ_KEY_MISS SIBS 183 280070AA SIBS_ERR_KEY_NAME_UNKNOWN SIBS 183 280070B0 ZKA_FRM_INT_ERROR ZKA 207 280070B1 RKL_ERR_OS_INTERNAL RKL 171 280070B2 LDE_FRM_NO_TERMINAL_DATA LDE 198 280070B2 OPT_FRM_NO_TERMINAL_DATA OPT 187 280070B2 ZKA_FRM_NO_TERMINAL_DATA ZKA 207 280070B3 ZKA_FRM_AMOUNT_RETRIES ZKA 207 280070B5 ZKA_FRM_AMOUNT_TO_LARGE ZKA 208

Page 722: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

714 June 2004

StCode StWarn Define Device Page

280070B8 ZKA_FRM_NEED_LOGIN ZKA 208 280070B9 ZKA_FRM_CURRENCY ZKA 208 280070BA ZKA_FRM_CHIP_TYPE ZKA 208 280070C1 ZKA_FRM_WRONG_CC_DATA ZKA 208 280070C2 ZKA_FRM_WRONG_CC_MAC ZKA 208 280070D0 OPT_FRM_PUT_GROUP OPT 188 280070D1 OPT_FRM_BMP62_TO_LONG OPT 188 280070D2 OPT_FRMDATA_BASE_STATE OPT 188 280070E0 ZKA_FRM_ISO_TYPE_L ZKA 209 280070E1 ZKA_FRM_ISO_AKZ_L ZKA 209 280070E2 ZKA_FRM_ISO_TRACE_L ZKA 209 280070E3 ZKA_FRM_FRM_CHARGING_FEE ZKA 209 280070E4 OPT_FRM_MAC OPT 188 280070E4 ZKA_FRM_ISO_MAC_L ZKA 209 280070E5 OPT_FRM_AC OPT 188 280070E5 ZKA_FRM_ISO_RESP_L ZKA 209 280070E6 ZKA_FRM_ISO_BMP62 ZKA 210 280070E7 ZKA_FRM_ISO_BMP62_AMOUNT ZKA 210 280070E8 ZKA_FRM_ISO_COND_CODE ZKA 210 280070E9 ZKA_FRM_ISO_BMP58 ZKA 210 280070EA ZKA_FRM_ISO_CARD_WRONG ZKA 210 280070EB ZKA_FRM_BANK_NUM_L ZKA 210 280070EF ZKA_FRM_NO_DATA_BLOCK ZKA 211 280070F0 OPT_FRM_APPLICATION_FLOW OPT 188 280070F0 ZKA_FRM_FLOW_CONTROL_L ZKA 211 280070F1 OPT_FRM_WRONG_PARAMETER OPT 189 280070F2 OPT_FRM_PS_NOT_SELECTED OPT 189 280070F2 ZKA_FRM_MESSAGE_STRUCT ZKA 211 280070F3 OPT_FRM_INTERNAL_ERROR OPT 189 280070F3 ZKA_FRM_CMD_NOT_POSIBLE ZKA 211 280070F4 ZKA_FRM_ADF_MAC ZKA 211 280070F5 OPT_FRM_NO_DATA_BASE OPT 189 280070F5 ZKA_FRM_AMOUNT ZKA 211 280070F6 ZKA_FRM_ADF_STATE ZKA 212 280070F7 OPT_FRM_MESSAGE_LENGTH OPT 189 280070F7 ZKA_FRM_CMD_LEN ZKA 212 280070F8 OPT_FRM_MESSAGE_TYPE OPT 189 280070F8 ZKA_FRM_PARA_CASH_ID ZKA 212 280070F9 OPT_FRM_ZKA_NUMBER OPT 190 280070F9 ZKA_FRM_ADF_LOCKED_L ZKA 212 280070FA OPT_FRM_MESSAGE OPT 190 280070FA ZKA_FRM_ISO_MESSAGE ZKA 212 280070FB OPT_FRM_DATE OPT 190 280070FB ZKA_FRM_CMD_CODE ZKA 212 280070FC OPT_FRM_AKZ OPT 190 280070FC ZKA_FRM_CCC ZKA 213 280070FD ZKA_FRM_RND_NUMBER ZKA 213 280070FE OPT_FRM_NO_LDI OPT 190

Page 723: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 715

StCode StWarn Define Device Page

280070FE ZKA_FRM_TID ZKA 213 280070FF ZKA_FRM_FUNCTION_L ZKA 213 28007110 CDM_R_LB_L27_COVERED CDM_FRM 442 28007111 CDM_R_LB_L27_RETRACT_COVERED CDM_FRM 443 28007112 CDM_R_LB_L27_UE_COVERED CDM_FRM 443 28007113 CDM_R_LB_L27_RETRACT_UE_COVERED CDM_FRM 443 28007118 CDM_R_LB_L27_NOT_REACHED CDM_FRM 444 28007119 CDM_R_LB_L27_BEFORE_RETR_FREE CDM_FRM 444 28007191 ZKA_FRM_PARA_MODE ZKA 213 28007192 ZKA_FRM_PARA_MODE_AUT ZKA 213 28007193 ZKA_FRM_PARA_DATE_TIME ZKA 214 28007194 ZKA_FRM_PIN_FORMAT ZKA 214 28007195 ZKA_FRM_NO_PIN ZKA 214 28007196 ZKA_FRM_WRONG_PIN ZKA 214 28007198 ZKA_FRM_WRONG_KEY ZKA 214 28007199 ZKA_FRM_FBZ ZKA 214 2800719A ZKA_FRM_RESULT ZKA 215 2800719F ZKA_FRM_MAC ZKA 215 280071E0 ZKA_FRM_ISO_TYPE ZKA 215 280071E1 ZKA_FRM_ISO_AKZ ZKA 215 280071E2 ZKA_FRM_ISO_TRACE ZKA 215 280071E4 ZKA_FRM_ISO_MAC ZKA 215 280071E5 ZKA_FRM_ISO_RESP ZKA 216 280071EB ZKA_FRM_ISO_BANK_NUM ZKA 216 280071EF ZKA_FRM_ISO_TID ZKA 216 280071F0 ZKA_FRM_FLOW_CONTROL ZKA 216 280071F2 ZKA_FRM_MESSAGE_STRUCT ZKA 216 280071F5 ZKA_FRM_AMOUNT ZKA 216 280071F6 ZKA_FRM_ADF_STATE ZKA 217 280071F7 ZKA_FRM_CMD_LEN ZKA 217 280071F9 ZKA_FRM_ADF_LOCKED ZKA 217 280071FB ZKA_FRM_CMD_CODE ZKA 217 280071FD ZKA_FRM_RND_NUMBER ZKA 217 280071FF ZKA_FRM_FUNCTION ZKA 217 28007210 CDM_R_LB_L28_COVERED CDM_FRM 444 28007211 CDM_R_LB_L28_RETRACT_COVERED CDM_FRM 445 28007218 CDM_R_LB_L28_NOT_REACHED CDM_FRM 445 28007219 CDM_R_LB_L28_RETR_NOT_REACHED CDM_FRM 445 28007310 CDM_R_LB_L29_COVERED CDM_FRM 446 28007311 CDM_R_LB_L29_RETRACT_COVERED CDM_FRM 446 28007318 CDM_R_LB_L29_NOT_REACHED CDM_FRM 446 28007319 CDM_R_LB_L29_RETR_NOT_REACHED CDM_FRM 447 28007410 CDM_R_LB_L30_COVERED CDM_FRM 447 28007411 CDM_R_LB_L30_RETRACT_COVERED CDM_FRM 447 28007418 CDM_R_LB_L30_NOT_REACHED CDM_FRM 448 28007419 CDM_R_LB_L30_RETR_NOT_REACHED CDM_FRM 448 28007510 CDM_R_LB_L31_COVERED CDM_FRM 448 28007511 CDM_R_LB_L31_RETRACT_COVERED CDM_FRM 449

Page 724: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

716 June 2004

StCode StWarn Define Device Page

28007518 CDM_R_LB_L31_NOT_REACHED CDM_FRM 449 28007519 CDM_R_LB_L31_RETR_NOT_REACHED CDM_FRM 449 28007610 CDM_R_LB_L32_COVERED CDM_FRM 450 28007611 CDM_R_LB_L32_RETRACT_COVERED CDM_FRM 450 28007618 CDM_R_LB_L32_NOT_REACHED CDM_FRM 450 28007619 CDM_R_LB_L32_RETR_NOT_REACHED CDM_FRM 451 28007710 CDM_R_LB_L33_COVERED CDM_FRM 451 28007711 CDM_R_LB_L33_RETRACT_COVERED CDM_FRM 451 28007718 CDM_R_LB_L33_NOT_REACHED CDM_FRM 452 28007719 CDM_R_LB_L33_RETR_NOT_REACHED CDM_FRM 452 28007910 CDM_R_LB_L35_COVERED CDM_FRM 452 28007911 CDM_R_LB_L35_RETRACT_COVERED CDM_FRM 453 28007918 CDM_R_LB_L35_NOT_REACHED CDM_FRM 453 28007919 CDM_R_LB_L35_RETR_NOT_REACHED CDM_FRM 453 28007B10 CDM_R_G9_NOT_REACHED CDM_FRM 454 28007B11 CDM_R_G9_RETRACT_NOT_REACHED CDM_FRM 454 28007C10 CDM_R_G8_NOT_REACHED CDM_FRM 454 28007C11 CDM_R_G8_RETRACT_NOT_REACHED CDM_FRM 455 28007FFF IDU_WARN_RESTART IDU 106 28007FFF SEL_WARN_RESTART SEL 125 28008000 DPS_FRM_UNDEF_ERROR DPS 608 28008000 EDM_FRM_UNDEF_ERROR EDM 155 28008000 RJ03_PAPER_END RJ03 325 28008000 SIBS_CMD_OK SIBS 183 28008001 CIN_DISK_JAM CIN 594 28008001 DPS_FRM_INVALID_COMMAND DPS 609 28008001 EDM_FRM_CMD_NOT_EXEC EDM 156 28008001 RJ03_CUTTER_JAM RJ03 325 28008001 SIBS_FRM_UNDEF_ERROR SIBS 183 28008002 CIN_COUNT_SECT_JAM CIN 594 28008002 DPS_FRM_INVALID_PARAM DPS 609 28008002 EDM_FRM_INVALID_KEY EDM 156 28008002 RJ03_HOME_POSITION RJ03 325 28008002 SCAN_INVALID_QUITT SCAN 243 28008002 SIBS_FRM_NO_ADF SIBS 184 28008003 CIN_NO_MAIN_STORAGE CIN 594 28008003 DPS_FRM_ERROR_CASSETTE DPS 609 28008003 EDM_FRM_RAM_ERROR EDM 156 28008003 RJ03_CARRIER_JAM RJ03 325 28008003 SCAN_CHECKSUM_ERROR SCAN 243 28008004 CIN_LOW_VOLTAGE CIN 595 28008004 DPS_FRM_NO_OPERATION DPS 609 28008004 EDM_FRM_PARITY_ERROR EDM 156 28008004 RJ03_MARK RJ03 326 28008004 SCAN_INVALID_FORM SCAN 243 28008005 CIN_REAL_TIME_CLOCK CIN 595 28008005 DPS_FRM_ENVELOPE_JAM DPS 609 28008005 EDM_FRM_EPROM_ERROR EDM 156

Page 725: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 717

StCode StWarn Define Device Page

28008005 RJ03_PRESENTER_JAM RJ03 326 28008005 SCAN_HARDWARE_ERROR SCAN 243 28008006 CIN_NO_VOLTAGE CIN 595 28008006 DPS_FRM_ERROR_TIMEOUT DPS 610 28008006 EDM_FRM_EEPROM_ERROR EDM 157 28008006 RJ03_RETRACTOR_JAM RJ03 326 28008006 SCAN_FIRMWARE_NOT_LOADED SCAN 244 28008007 DPS_FRM_ERROR_ENTRY DPS 610 28008007 EDM_FRM_CMD_NOT_EXIST EDM 157 28008007 RJ03_JAM RJ03 326 28008007 SCAN_TIMEOUT_VID_SCAN SCAN 244 28008008 CIN_COIN_RECOGNITION CIN 595 28008008 DPS_FRM_ERROR_SHUTTER DPS 610 28008008 EDM_FRM_KEY_RAM_ERROR EDM 157 28008008 RJ03_HIGH_VOLTAGE RJ03 326 28008008 SCAN_HARDWARE_XM_ERROR SCAN 244 28008009 DPS_FRM_SHUTTER_NOT_EMPTY DPS 610 28008009 EDM_FRM_LENGTH_ERROR EDM 157 28008009 RJ03_LOW_VOLTAGE RJ03 326 28008009 SCAN_HARDWARE_UQ_ERROR SCAN 244 2800800A CIN_START_CALIBRATE CIN 595 2800800A DPS_FRM_SHUTTER_OPEN DPS 611 2800800A EDM_FRM_BLOCK_IDENT EDM 157 2800800A RJ03_HEAD RJ03 327 2800800A SCAN_DRV_WRITE_ERROR SCAN 244 2800800B CIN_TEACH_CALIBRATE CIN 595 2800800B DPS_FRM_OUT_OF_ENVELOPES DPS 611 2800800B EDM_FRM_DEVICE_ID EDM 157 2800800B RJ03_TYPE RJ03 327 2800800C CIN_FLAP_INTERMEDIATE_STORAGE CIN 596 2800800C DPS_FRM_SIG_SDOUT DPS 611 2800800C EDM_FRM_COMMAND_ACTIVE EDM 158 2800800C RJ03_OP_AFTER_POWER_ON_ERR RJ03 327 2800800D CIN_FLAP_MAIN_STORAGE CIN 596 2800800D DPS_FRM_ERROR_PRINTER DPS 611 2800800D EDM_FRM_DATA_LENGTH_ERR EDM 158 2800800D RJ03_NO_PAPER_MOTION RJ03 327 2800800E CIN_POSITION_FUNNEL CIN 596 2800800E DPS_FRM_ERROR_PRN_TRANSPORT DPS 611 2800800E EDM_FRM_OUTPUT_PARA EDM 158 2800800F CIN_INTERNAL_MEMORY_ERROR CIN 596 2800800F DPS_FRM_SIG_SPHEAD DPS 612 2800800F EDM_FRM_UNDEF_DATA EDM 158 28008010 CCM_NO_ATR CCM 113 28008010 DPS_FRM_SIG_SPOUT DPS 612 28008010 EDM_FRM_CHECKSUM_ERROR EDM 158 28008010 SCO_CHIP_MISSING SCO 164 28008010 SEP_FRM_PPV_ERROR SEP 175

Page 726: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

718 June 2004

StCode StWarn Define Device Page

28008011 CCM_CHIP_NO_ANSWER CCM 113 28008011 DPS_FRM_ERROR_ADD_TRANSPORT DPS 612 28008011 EDM_FRM_ID_ERROR EDM 158 28008011 SCO_CHIP_NOT_SELECTED SCO 164 28008011 SEP_FRM_NO_PPV SEP 175 28008012 CCM_CHIP_NOT_SELECTED CCM 113 28008012 DPS_FRM_SIG_SCINSIDE DPS 612 28008012 SCO_P1P2_ERROR SCO 164 28008012 SEP_FRM_NO_PIN_BLOCK SEP 176 28008013 CCM_CONT_RAM_ERROR CCM 114 28008013 DPS_FRM_SIG_SCMIDDLE DPS 612 28008013 SCO_APL_NO_INIT SCO 165 28008013 SEP_FRM_NO_PIN_CHANGE SEP 176 28008014 CCM_CONT_CODE_ERROR CCM 114 28008014 DPS_FRM_SIG_SCOUT DPS 612 28008014 SCO_CHIP_AUTH_ERROR SCO 165 28008014 SEP_FRM_PIN_CHANGE_ERROR SEP 176 28008015 CIN_NO_EJECT_BOX CIN 596 28008015 DPS_FRM_ERROR_OUT_OF_PLACE DPS 613 28008015 SCO_CHIP_TIMEOUT_ERROR SCO 165 28008015 SEP_FRM_NO_SECURITY_BLOCK SEP 176 28008016 DPS_FRM_ERROR_DISPENSER DPS 613 28008016 SCO_CHIP_EFDAT_ERROR SCO 165 28008016 SEP_FRM_HASH_ERROR SEP 176 28008017 DPS_FRM_ERROR_PRN_HEAD DPS 613 28008017 SCO_CHIP_CHALLENGE_ERROR SCO 165 28008017 SEP_FRM_PVV_KEY_ERROR SEP 176 28008018 DPS_FRM_ERROR_ENVELOPE_LEN DPS 613 28008018 SCO_CHIP_CONT_RAM_ERROR SCO 165 28008018 SEP_FRM_PVV_PIN_ERROR SEP 177 28008019 DPS_FRM_ENVELOPE_NOT_FOUND DPS 613 28008019 SCO_CHIP_CONT_CODE_ERROR SCO 166 28008019 SEP_FRM_NO_CARD_FUNCTION SEP 177 2800801A SEP_FRM_NO_KEY_FUNCTION SEP 177 2800801B SEP_FRM_PVV_TP_KEY_INVALID SEP 177 2800801C SEP_FRM_PVV_BK_KEY_INVALID SEP 177 2800801D SEP_FRM_WRONG_MODE SEP 177 2800801E SEP_FRM_BUFFER_FULL SEP 178 2800801F SEP_FRM_WRONG_TUNPACK SEP 178 28008020 DPS_FRM_SIG_ENV DPs 613 28008020 MDM_WRONG_BLOCK_ID MDM 662 28008020 PPD_FRM_INVALID_BLOCK_ID PPD 669 28008020 SEL_INVALID_BLK_ID SEL 121 28008021 DPS_FRM_OPEN_BANDAGE DPS 614 28008021 MDM_WRONG_DEVICE_ID MDM 662 28008021 PPD_FRM_INVALID_DEV_ID PPD 669 28008021 SEL_INVALID_DEV_ID SEL 121 28008022 DPS_FRM_CLOSE_BANDAGE DPS 614

Page 727: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 719

StCode StWarn Define Device Page

28008022 MDM_WRONG_JOB_SPEC MDM 662 28008022 PPD_FRM_INVALID_JOB_ID PPD 669 28008023 DPS_FRM_DISPENSE_TIMEOUT DPS 614 28008023 MDM_SMALL_REC_BUFF MDM 662 28008023 PPD_FRM_INVALID_BUFFER_LEN PPD 669 28008023 SEL_INVALID_BLK_LEN SEL 121 28008024 DPS_FRM_CRIT_ERROR_SHUTTER DPS 614 28008024 MDM_ERROR_JOB_SPEC MDM 662 28008024 OPT_ERR_PUT_BMP62 OPT 190 28008024 PPD_FRM_INVALID_JOB PPD 669 28008025 DPS_FRM_CRIT_ERROR_BANDAGE DPS 614 28008025 MDM_JOB_NOT_READY MDM 663 28008025 SEL_TASK_NOT_ENDED SEL 121 28008030 MDM_DOOR_NOT_OPENED MDM 663 28008030 PPD_FRM_MOTION_ERROR PPD 670 28008031 MDM_DOOR_NOT_CLOSED MDM 663 28008031 SEL_UNKNOWN_REQUEST SEL 121 28008032 SEL_INCORRECT_FORMAT SEL 121 28008033 SEL_ILLEGAL_PARAMETER SEL 122 28008034 SEL_NO_PROC_REQUEST SEL 122 28008036 SEL_ERROR_RAM SEL 122 28008037 SEL_EPROM_ERROR SEL 122 28008038 SEL_EEPROM_ERROR SEL 122 28008040 EDM_FRM_TRANSAC_N_ACTIVE EDM 159 28008040 MDM_GENERAL_HW_ERROR MDM 663 28008040 PPD_FRM_GENERAL_HW_ERROR PPD 670 28008040 SEL_ILLEGAL_LED_PARA SEL 123 28008041 EDM_FRM_INVALID_PINLEN EDM 159 28008041 MDM_EPROM_FAILURE MDM 664 28008041 PPD_FRM_EPROM_ERROR PPD 670 28008041 SEL_WRONG_KEY_PARITY SEL 123 28008042 MDM_EEPROM_FAILURE MDM 664 28008042 SEL_ILLEGAL_SEQUENCE SEL 123 28008043 MDM_PROCESSOR_FAILURE MDM 664 28008043 PPD_FRM_PROCESSOR_FAILURE PPD 670 28008044 PPD_FRM_CHECKSUM_ERROR PPD 670 28008045 EDM_FRM_KEY_EXISTS EDM 159 28008045 MDM_LB_FAILURE MDM 664 28008046 EDM_FRM_KEY_NOT_FOUND EDM 159 28008046 MDM_WAIT_EXCEEDED MDM 665 28008047 EDM_FRM_KEY_NOT_ALLOWED EDM 159 28008048 EDM_FRM_NO_RSA_PROCESSOR EDM 159 28008049 EDM_FRM_WRONG_RSA_KEY_LEN EDM 160 28008050 EDM_FRM_SP_EPROM_ERROR EDM 160 28008050 LB_LIMIT MDM 665 28008050 PPD_NOT_COMPLETE_OPENED PPD 673 28008051 EDM_FRM_SP_CHECK_ERROR EDM 160 28008051 LIGHT_FAILURE MDM 665

Page 728: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

720 June 2004

StCode StWarn Define Device Page

28008051 PPD_NOT_COMPLETE_CLOSED PPD 673 28008052 EDM_FRM_SP_PARITY_ERROR EDM 160 28008052 MDM_DOOR_N_COMPLETE_OPENED MDM 665 28008052 PPD_SWITCH_UNIT_WRN PPD 673 28008053 EDM_FRM_SP_TABLE_ERROR EDM 160 28008053 PPD_LIGHT_BARRIER_WRN PPD 674 28008054 PPD_HEAVY_MOVEABLE PPD 674 28008055 PPD_FRM_NOT_LOAD_WRN PPD 674 28008060 EDM_FRM_X_ERROR EDM 160 28008061 EDM_FRM_BATTERY_EMPTY EDM 161 28008062 EDM_FRM_KEY_ENTRY_ERROR EDM 161 28008063 EDM_FRM_APSS_KEY_ERROR EDM 161 28008064 EDM_FRM_WRONG_KEK EDM 161 28008065 EDM_FRM_SCOP_AUTHENTICATE EDM 161 28008066 EDM_FRM_SCOP_PARA_TYPE EDM 161 28008067 EDM_FRM_SCOP_PARA EDM 162 28008068 EDM_FRM_SCOP_PARA_LENGTH EDM 162 280080E0 PPD_FRMLD_INVALID_BLK_LEN_CHAR PPD 671 280080E1 PPD_FRMLD_INVALID_BLK_LEN PPD 671 280080E2 PPD_FRMLD_INVALID_BLK PPD 671 280080E3 PPD_FRMLD_INVALID_BLK_ID PPD 671 280080E4 PPD_FRMLD_INVALID_DEV_ID PPD 671 280080E5 PPD_FRMLD_INVALID_COMMAND PPD 671 280080E6 PPD_FRMLD_INVALID_CMD_PARA PPD 672 280080E7 PPD_FRM_JOB_NOT_READY PPD 672 280080E8 DPS_FRM_NOT_LOADED DPS 615 280080E8 PPD_FRM_NOT_LOAD PPD 672 280080E9 PPD_FRMLD_INVALID_FILE_LEN PPD 672 280080EA DPS_FRM_NOT_ENOUGH_MEMORY DPS 615 280080EA PPD_FRMLD_INVALID_MEM PPD 672 280080EB DPS_FRM_FILE_CHECKSUM DPS 615 280080EB PPD_FRMLD_INVALID_FILE_CRC PPD 673 280080EC DPS_FRM_HARDWARE_ERROR DPS 615 280080EC PPD_FRMLD_HW_ERROR PPD 673 280080F0 DPS_FRM_COMMAND_CANCELED DPS 615 28008100 PRT_DEVICE ND71 247 28008100 PRT_DEVICE ND79 253 28008100 PRT_NO_PAPER HPEM 288 28008100 PRT_NO_PAPER ND05 228 28008100 PRT_PRESENTER_ERR ND99 275 28008100 PRT_VOLTAGE ND94 257 28008100 TH21_PAPER_END TH21 283 28008101 PRT_CARRIER ND94 257 28008101 PRT_DEVICE_CMD_REC ND71 247 28008101 PRT_DEVICE_CMD_REC ND79 253 28008101 PRT_PAPER_JAM ND05 229 28008101 PRT_TOF_ERR ND99 276 28008101 TH21_COVER TH21 283

Page 729: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 721

StCode StWarn Define Device Page

28008102 PRT_DATA_TRANSMISSION_ERROR HPEM 288 28008102 PRT_DATA_TRANSMISSION_ERROR ND05 229 28008102 PRT_HEAD_LIFTED ND99 276 28008102 PRT_MEMORY ND71 247 28008102 PRT_MEMORY ND94 257 28008102 PRT_MEMORY ND97 264 28008102 TH21_PRINT_HEAD TH21 284 28008103 PRT_FORMAT_LOGO ND71 247 28008103 PRT_FORMAT_LOGO ND79 253 28008103 PRT_FORMAT_LOGO ND99 276 28008103 PRT_MAGNETIC_STRIPE_ERROR HPEM 288 28008103 PRT_PAPER_END ND94 258 28008103 PRT_PAPER_END ND97 264 28008103 PRT_SW_SYNTAX_ERROR ND05 229 28008103 TH21_POWER_LOST TH21 284 28008104 PRT_NO_MARK ND94 258 28008104 PRT_NO_MARK ND97 264 28008104 PRT_PARITY ND71 247 28008104 PRT_PARITY ND79 254 28008104 PRT_PARITY ND99 276 28008104 PRT_SW_SEMANTIK_ERROR ND05 229 28008104 TH21_PAPER_JAM TH21 284 28008105 PRT_CHECKSUM ND71 248 28008105 PRT_HARDWARE_ERR HPEM 288 28008105 PRT_HARDWARE_ERR ND99 276 28008105 PRT_NO_ANSWER ND05 229 28008105 PRT_RESET_ERROR_DRUM ND94 258 28008105 PRT_RESET_ERROR_DRUM ND97 264 28008105 TH21_CUTTER TH21 284 28008106 PRT_HW_MAIN_BOARD_ERROR ND05 230 28008106 PRT_POWER_LOST HPEM 289 28008106 PRT_POWER_LOST ND71 248 28008106 PRT_POWER_LOST ND79 254 28008106 PRT_POWER_LOST ND99 276 28008106 PRT_RESET_ERROR_KNIFE ND94 258 28008106 PRT_RESET_ERROR_KNIFE ND97 264 28008106 TH21_MEMORY TH21 284 28008107 PRT_BON_PAPER_END ND71 248 28008107 PRT_BON_PAPER_END ND79 254 28008107 PRT_BON_PAPER_END ND99 277 28008107 PRT_HW_ERROR_HOR ND05 230 28008107 PRT_TRANSPORT_ERROR ND94 258 28008107 PRT_TRANSPORT_ERROR ND97 265 28008108 PRT_BON_PAPER_END_FIN ND71 248 28008108 PRT_BON_PAPER_END_FIN ND79 254 28008108 PRT_COLLECTING_TRAY_FULL ND94 258 28008108 PRT_COLLECTING_TRAY_FULL ND97 265 28008108 PRT_PAPER_WIDE ND05 230

Page 730: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

722 June 2004

StCode StWarn Define Device Page

28008108 PRT_SOFTWARE_ERR ND99 277 28008109 PRT_BON_PAPER_JAM ND71 249 28008109 PRT_BON_PAPER_JAM ND79 254 28008109 PRT_BUFF_OVERFLOW ND99 277 28008109 PRT_HW_ERROR_ZEKOSA ND05 230 28008109 PRT_OUTPUT_SLOT_OCCUPIED ND94 259 28008109 PRT_OUTPUT_SLOT_OCCUPIED ND97 265 2800810A PRT_BON_PAPER_JAM_CMD_REC ND71 249 2800810A PRT_BON_PAPER_JAM_CMD_REC ND79 255 2800810A PRT_CMD_REC ND99 277 2800810A PRT_FONT_SET_NOT_FOUND ND94 259 2800810A PRT_FONT_SET_NOT_FOUND ND97 265 2800810A PRT_HW_ERROR_BELEG ND05 231 2800810B PRT_CUTTER ND99 277 2800810B PRT_JOURNAL_PAPER_END ND71 249 2800810B PRT_NO_PAPER_ACCEPT HPEM 289 2800810B PRT_NO_PAPER_ACCEPT ND05 231 2800810B PRT_PAPER_STILL_IN_TONGS ND94 259 2800810B PRT_PAPER_STILL_IN_TONGS ND97 265 2800810C PRT_EXTERNAL_LIGHT ND94 259 2800810C PRT_EXTERNAL_LIGHT ND97 266 2800810C PRT_FORMAT_CHAR ND99 278 2800810C PRT_JOURNAL_PAPER_END_FIN ND71 249 2800810C PRT_REJECT_SLOT_FULL ND05 231 2800810D PRT_JOURNAL_PAPER_TEAR ND71 249 2800810D PRT_ROCKER_KNIFE_DRUM_FAULT ND94 260 2800810D PRT_ROCKER_KNIFE_DRUM_FAULT ND97 266 2800810D PRT_WRONG_STATUS ND05 231 2800810E PRT_JOURNAL_PAPER_TEAR_CMD_REC ND71 250 2800810E PRT_OUTPUT_SLOT_SHUTTER_FAULT ND94 260 2800810E PRT_OUTPUT_SLOT_SHUTTER_FAULT ND97 266 2800810E PRT_PRINTER_STOP ND05 231 2800810F PRT_COUNTERS_DEFAULT_SET ND94 260 2800810F PRT_NO_FIRMWARE_LOADED ND99 278 2800810F PRT_PRINTER_ERROR ND05 232 2800810F PRT_SWITCH HPEM 289 2800810F PRT_SWITCH ND71 250 28008110 PRT_PAPER_TRAY HPEM 289 28008110 PRT_PAPER_TRAY ND05 232 28008110 PRT_PRINT_CONTROL_ERROR ND94 260 28008110 PRT_SWITCH_CMD_REC ND71 250 28008111 PRT_MORE_ERRORS HPEM 289 28008111 PRT_MORE_ERRORS ND05 232 28008111 PRT_MORE_ERRORS ND71 250 28008111 PRT_MORE_ERRORS ND79 255 28008111 PRT_MORE_ERRORS ND97 266 28008112 PRT_MARK_ERROR ND71 250 28008112 PRT_NO_PAPER_REJECT ND05 232

Page 731: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 723

StCode StWarn Define Device Page

28008112 PRT_SERVICE_POSITION ND79 255 28008112 PRT_TO_MANY_REJECTS ND97 266 28008113 PRT_INTERN_SOFTWARE_ERROR ND97 267 28008113 PRT_USER_ERROR ND79 255 28008113 PRT_WRONG_PARAMETER ND05 232 28008114 PRT_SERVICE_POSITION_CMD_REC ND79 255 28008114 PRT_SHUTTER_ERROR ND05 232 28008115 PRT_PAPER_LENGTH ND05 233 28008116 PRT_WRONG_PAGE ND05 233 28008120 PRT_DRUM_COVER_NOT_CLOSED ND97 267 28008121 PRT_NO_PAPER_LANE ND97 267 28008122 PRT_PAPER_END_LANE2 ND97 267 28008123 PRT_PRINT_CONTROL_ERROR ND97 267 28008124 PRT_GRAPHIC_ABORT ND97 268 28008124 PRT_WRONG_LINE ND05 233 28008125 PRT_GRAPHIC_WRONG_COMMAND ND97 268 28008125 PRT_NO_PARK_STATION ND05 233 28008126 PRT_NO_PAPER_PARKED ND05 233 28008127 PRT_PAPER_PARKED ND05 234 28008128 PRT_DISPENSE_BOX_NOT_OK ND05 234 28008129 PRT_UNIT_NOT_AVAILABLE ND05 234 2800812A PRT_SYNTAX_ERROR_ZEKOSA ND05 234 2800812B PRT_COVER_OPEN ND05 234 2800812C PRT_TURN_UNIT_ERROR ND05 235 2800812D PRT_UNIT_ERROR_RETRACT ND05 235 2800812E PRT_WRONG_PAGE_LINE ND05 235 2800812F PRT_WRONG_OMR_CMD ND05 235 28008130 PRT_ADD_ON_BOARD_ERROR ND05 236 28008401 LDE_FRM_FORMAT_ERR LDE 198 28008401 SEP_FRM_FORMAT_ERR SEP 178 28008401 ZKA_FRM_FORMAT_ERR ZKA 218 28008402 LDE_FRM_PROT_ERR LDE 199 28008402 SEP_FRM_PROT_ERR SEP 178 28008402 ZKA_FRM_PROT_ERR ZKA 218 28008403 LDE_FRM_HW_LOCK LDE 199 28008403 SEP_FRM_HW_LOCK SEP 178 28008403 ZKA_FRM_HW_LOCK ZKA 218 28008404 LDE_FRM_SECURITY_LOCK LDE 199 28008404 SEP_FRM_SECURITY_LOCK SEP 178 28008404 ZKA_FRM_SECURITY_LOCK ZKA 218 28008405 LDE_UNKNOWN_CMD LDE 199 28008405 OPT_FRM_UNKNOWN_CMD OPT 191 28008405 SEP_FRM_UNKNOWN_CMD SEP 179 28008405 ZKA_UNKNOWN_CMD ZKA 218 28008406 LDE_FRM_ADF_TO_LARGE LDE 199 28008406 SEP_FRM_ADF_TO_LARGE SEP 179 28008406 ZKA_FRM_ADF_TO_LARGE ZKA 218 28008407 LDE_FRM_WRONG_STATE LDE 199

Page 732: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

724 June 2004

StCode StWarn Define Device Page

28008407 SEP_FRM_WRONG_STATE SEP 179 28008407 ZKA_FRM_WRONG_STATE ZKA 219 28008408 LDE_FRM_NO_ADF LDE 200 28008408 OPT_FRM_NO_ADF OPT 191 28008408 SEP_FRM_NO_ADF SEP 179 28008408 ZKA_FRM_NO_ADF ZKA 219 28008409 LDE_FRM_INTERNAL_ERR LDE 200 28008409 SEP_FRM_INTERNAL_ERR SEP 179 28008409 ZKA_FRM_INTERNAL_ERR ZKA 219 2800840C LDE_FRM_RAM_OVERFLOW LDE 200 2800840C SEP_FRM_RAM_OVERFLOW SEP 179 2800840C ZKA_FRM_RAM_OVERFLOW ZKA 219 2800840D LDE_FRM_LOAD_LEN LDE 200 2800840D SEP_FRM_LOAD_LEN SEP 180 2800840D ZKA_FRM_LOAD_LEN ZKA 219 2800840E LDE_FRM_CHECKSUM_ERR LDE 200 2800840E SEP_FRM_CHECKSUM_ERR SEP 180 2800840E ZKA_FRM_CHECKSUM_ERR ZKA 219 2800840F LDE_FRM_ADF_LOCKED LDE 200 2800840F SEP_FRM_ADF_LOCKED SEP 180 2800840F ZKA_FRM_ADF_LOCKED ZKA 220 28008413 LDE_FRM_MAC_ERR LDE 201 28008413 SEP_FRM_MAC_ERR SEP 180 28008413 ZKA_FRM_MAC_ERR ZKA 220 28008414 LDE_OPT_VERSION_ERR LDE 201 28008432 LDE_OPT_KEY_BLOCKED LDE 201 28008434 LDE_OPT_LDI_BLOCKED LDE 201 28008435 LDE_OPT_CREATE_ERROR LDE 201 28008436 LDE_OPT_NO_ADF LDE 201 28008437 LDE_OPT_WRONG_STATE LDE 202 2800843B LDE_OPT_PARAM_ERR LDE 202 2800843C LDE_OPT_OUTOFORDER LDE 202 28008447 LDE_OPT_VORINIT_ERR LDE 202 28008448 LDE_OPT_REG_ERR LDE 202 28008449 LDE_OPT_NO_STD_LDI LDE 202 2800844C LDE_OPT_NO_DATABASE LDE 203 2800844D LDE_OPT_NO_LDI LDE 203 28009000 CDM_MS_TIMEOUT CDM_FRM 455 28009100 CDM_LBAMP_TIMEOUT CDM_FRM 455 28009103 CIT_JOB_CANCELED CIT 142 28009200 CDM_CUS_RELAIS_NOT_AVAIL CDM_FRM 456 2800A100 SEV4_ERR_NO_CMD_RESPONSE SEL 123 2800A101 SEV4_ERR_STILL_BUSY SEL 124 2800A102 SEV4_ERR_COMMAND_NOT_VALID SEL 124 2800A103 SEV4_ERR_COMMAND_PARA_NOT_VALID SEL 124 2800A104 SEV4_ERR_SELF_TEST SEL 124 2800A105 SEV4_ERR_WRITE_FLASH SEL 124 2800A106 SEV4_ERR_LOAD_SECURITY SEL 125

Page 733: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 725

StCode StWarn Define Device Page

2800A107 SEV4_ERR_NO_TRANSPORT_KEY_LOADED SEL 125 2800AFFF SEV4_WARN_RESTART SEL 126 2800B000 CDM_CAS_RELEASE_ERROR CDM_FRM 456 2800B100 CDM_CAS_INSERT_ERROR CDM_FRM 456 2800B200 CDM_REJ_CAS_NOT_AVAIL CDM_FRM 456 2800B300 CDM_CAS_NOT_AVAIL CDM_FRM 457 2800B400 CDM_CAS_HANDLING_TIMEOUT CDM_FRM 457 2800B510 CDM_MS_EEPROM_ERROR CDM_FRM 457 2800B511 CDM_MS_MOTOR_ERROR CDM_FRM 457 2800B512 CDM_MS_MOTOR_SPEED_ERROR CDM_FRM 457 2800B513 CDM_MS_CPU_ERROR CDM_FRM 458 2800B514 CDM_MS_EPROM_ERROR CDM_FRM 458 2800B523 CDM_CAS_BUSY CDM_FRM 458 2800B530 CDM_CAS_NO_REJECT_POSSIBLE CDM_FRM 458 2800B531 CDM_CAS_NO_RETRACT_POSSIBLE CDM_FRM 458 2800B534 CDM_CAS_CPU_ERROR CDM_FRM 458 2800B535 CDM_CAS_RAM_ERROR CDM_FRM 459 2800B536 CDM_CAS_EPROM_CHKSUM_ERROR CDM_FRM 459 2800B537 CDM_CAS_EEPROM_CHKSUM_ERROR CDM_FRM 459 2800B538 CDM_CAS_CLUTCH_ERROR CDM_FRM 459 2800B539 CDM_CAS_DEDUCTIONFLAG_ERROR CDM_FRM 459 2800B544 CDM_LBAMP_HW_ERROR CDM_FRM 459 2800B545 CDM_LBAMP_DISP_HW_NOT_AVAIL CDM_FRM 460 2800B546 CDM_LBAMP_INVALID_CONFIG CDM_FRM 460 2800B547 CDM_LBAMP_LB_NOT_OFF CDM_FRM 460 2800B548 CDM_LBAMP_INVALID_SPEC CDM_FRM 460 2800B600 CDM_CAS_AREA_NOT_AVAIL CDM_FRM 460 2800B700 CDM_CAS_NO_FREE_BLK_AVAIL CDM_FRM 461 2800B800 CDM_CAS_AREA_ALREADY_EXIST CDM_FRM 461 2800B900 CDM_CAS_INVALID_CHAR CDM_FRM 461 2800BA00 CDM_CAS_WRITE_PROT_ERROR CDM_FRM 461 2800BB00 CDM_CAS_EEPROM_ERROR CDM_FRM 462 2800BC00 CDM_CAS_AREA_CLR_NOT_AVAIL CDM_FRM 462 2800BD00 CDM_CAS_PASSWORD_ERROR CDM_FRM 462 2800BE00 CDM_CAS_SYNTAX_ERROR CDM_FRM 462 2800C000 CDM_INVALID_CAS CDM_FRM 463 2800C100 CDM_CAS_SW_LOCK CDM_FRM 463 2800C200 CDM_CAS_HW_LOCK CDM_FRM 463 2800C300 CDM_REF_INIT_ERROR CDM_FRM 463 2800C400 CDM_REF_INVALID_NR_NOTES CDM_FRM 463 2800C500 CDM_REF_TABLE_FULL CDM_FRM 464 2800C600 CDM_CAS_PRESSURE_ERROR CDM_FRM 464 2800C800 MSS_MODULE_DATA_ERROR MSS 108 2800C801 MSS_MODULE_ERROR_NSN MSS 108 2800C802 MSS_MODULE_ERROR_EODT MSS 108 2800C803 MSS_MODULE_ERROR_CBS MSS 108 2800C804 MSS_MODULE_ERROR_RT3 MSS 108 2800C805 MSS_MODULE_ERROR_EOT3 MSS 108

Page 734: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

726 June 2004

StCode StWarn Define Device Page

2800C806 MSS_MODULE_ERROR_SVR MSS 109 2800C807 MSS_MODULE_ERROR_PST MSS 109 2800C808 MSS_MODULE_HW_ERROR_1 MSS 109 2800C809 MSS_MODULE_HW_ERROR_2 MSS 109 2800C80A MSS_MODULE_HW_ERROR_3 MSS 109 2800C80B MSS_MODULE_HW_ERROR_4 MSS 109 2800C80C MSS_MODULE_HW_ERROR_5 MSS 110 2800C80D MSS_MODULE_HW_ERROR_6 MSS 110 2800C80E MSS_MODULE_HW_ERROR_7 MSS 110 2800C80F MSS_MODULE_HW_ERROR_8 MSS 110 2800C810 MSS_MODULE_HW_ERROR_9 MSS 110 2800CC01 MSS_MM_READ_TIMEOUT MSS 110 2800CC05 MSS_MM_WRITE_TIMEOUT MSS 111 2800CC08 MSS_MM_OVERRUN_ERROR MSS 111 2800CC09 MSS_MM_PARITY_ERROR MSS 111 2800CC0A MSS_MM_FRAMING_ERROR MSS 111 2800CC0C MSS_MM_INVALID_DATA MSS 111 2800D000 CDM_TRANS_KEY_NOT_AVAIL CDM_FRM 464 2800D100 CDM_LINE_KEY_NOT_AVAIL CDM_FRM 464 2800D200 CDM_DOOR_CLOSED CDM_FRM 465 2800D300 CDM_KEY_TEST_ERROR CDM_FRM 465 2800D400 CDM_ENCRYPT_OFF CDM_FRM 465 2800D500 CDM_INVALID_IV CDM_FRM 465 2800D600 CDM_ENCPRYTION_ERROR CDM_FRM 465 2800E000 CCDM_WARN_ENTRY_HANDLING CCDM 635 2800E000 CNG_WARN_MONEY_NOT_REMOVED CNG 494 2800E000 IDU_FRM_INVALID_COM_CODE IDU 98 2800E001 CCDM_WARN_BUNDLE_NOT_INSERTED CCDM 636 2800E001 CNG_WARN_MONEY_REMOVED CNG 494 2800E001 IDU_FRM_INVALID_PARAMETER IDU 98 2800E002 CCDM_WARN_BUNDLE_NOT_REMOVED CCDM 636 2800E002 IDU_FRM_NO_COM_EXECUTE IDU 98 2800E003 CCDM_WARN_BUNDLE_REMOVED CCDM 636 2800E004 CCDM_WARN_SHEETS_AVAILABLE CCDM 636 2800E004 IDU_FRM_COM_DATA_ERROR IDU 98 2800E005 CNG_WARN_ENTRY_HANDLING CNG 494 2800E006 IDU_FRM_MAINTENANCE_MODE IDU 98 2800E007 CNG_WARN_PROTOCOL_RETRY CNG 494 2800E009 IDU_FRM_OTHER_COM_ERROR IDU 99 2800E00A CCDM_NO_ACTUAL_FIRMWARE CCDM 636 2800E00A IDU_FRM_CARD_JAM IDU 99 2800E00B CCDM_NO_FIRMWARE CCDM 636 2800E00B IDU_FRM_SHUTTER_FAIL IDU 99 2800E00C CCDM_WARN_LED CCDM 637 2800E00C IDU_FRM_SENSOR_FAIL IDU 99 2800E00D IDU_FRM_CARD_TOO_LONG IDU 99 2800E00E IDU_FRM_CARD_TOO_SHORT IDU 100 2800E00F IDU_FRM_MEMORY_ERROR IDU 100

Page 735: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 727

StCode StWarn Define Device Page

2800E010 CCDM_WARN_CY_NEW CCDM 637 2800E010 IDU_FRM_CARD_POS_MOVE IDU 100 2800E011 CCDM_WARN_CY_NEW_EMPTY CCDM 637 2800E011 IDU_FRM_JAM_RETRIEVE IDU 100 2800E012 IDU_FRM_SW1_SW2 IDU 100 2800E013 IDU_FRM_MECHANICAL IDU 100 2800E014 CCDM_WARN_FRM_NEW CCDM 637 2800E014 IDU_FRM_READ_PARITY IDU 101 2800E015 CCDM_WARN_CY_INCONSISTENT CCDM 637 2800E015 IDU_FRM_READ IDU 101 2800E016 IDU_FRM_WRITE IDU 101 2800E017 IDU_FRM_READ_EOF IDU 101 2800E01E IDU_FRM_POWER IDU 102 2800E01F IDU_FRM_DSR_OFF IDU 102 2800E028 IDU_FRM_CARD_EJECT IDU 102 2800E070 IDU_FRM_NO_FIRMWARE IDU 102 2800E071 IDU_FRM_INVALID_DOWNLOAD IDU 102 2800E100 IDU_FRM_NO_STRIPE IDU 103 2800E101 IDU_FRM_JAM_STACKER IDU 103 2800E102 IDU_FRM_NO_CARD_IN_STACKER IDU 103 2800E104 IDU_FRM_CARD_TRAP IDU 103 2800E180 IDU_CHIP_DEFECT_CONTROLLER IDU 103 2800E182 IDU_CHIP_INVALID_ACTIVATION IDU 104 2800E183 IDU_CHIP_INVALID_DEACTIVATION IDU 104 2800E184 IDU_CHIP_COMMUNICATION IDU 104 2800E185 IDU_CHIP_FORCED_INTERRUPT IDU 104 2800E186 IDU_CHIP_INVALID_RESPONSE IDU 104 2800E187 IDU_CHIP_INVALID_ATR IDU 105 2800F000 CCDM_FRM_SW_MISSING CCDM 630 2800F000 CNG_FRM_SW_MISSING CNG 491 2800F001 CCDM_FRM_SYNTAX CCDM 630 2800F001 CNG_FRM_SYNTAX CNG 491 2800F002 CCDM_FRM_DEVICE_NOT_READY CCDM 630 2800F002 CNG_FRM_DEVICE_NOT_READY CNG 491 2800F003 CCDM_FRM_ERROR CCDM 630 2800F003 CNG_FRM_ERROR CNG 491 2800F004 CCDM_FRM_DOOR_NOT_OPEN CCDM 630 2800F004 CNG_FRM_DOOR_NOT_OPEN CNG 491 2800F005 CCDM_FRM_CONTEXT CCDM 631 2800F005 CNG_FRM_CONTEXT CNG 492 2800F006 CCDM_FRM_NO_BUNDLE_AVAILABLE CCDM 631 2800F006 CNG_FRM_ERROR_DECRYPTION CNG 492 2800F007 CCDM_FRM_BUNDLE_NOT_REMOVED CCDM 631 2800F007 CNG_FRM_MONEY_NOT_REMOVED CNG 492 2800F008 CCDM_FRM_ENTRY CCDM 631 2800F008 CNG_FRM_SCOP CNG 492 2800F009 CCDM_FRM_BOOT CCDM 631 2800F00A CCDM_SENS_HW_ERROR CCDM 632

Page 736: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

728 June 2004

StCode StWarn Define Device Page

2800F00B CCDM_SENS_FRM_ERROR CCDM 632 2800F00C CCDM_SENS_COM_ERROR CCDM 632 2800F00D CCDM_SENS_DATA_ERROR CCDM 632 2800F00E CCDM_SENS_NOTE_TAB_ERROR CCDM 633 2800F00F CCDM_FRM_SENS_WRONG_NOTE_ASSIGN CCDM 633 2800F010 CCDM_SENS_READER_ERROR CCDM 633 2800F011 CCDM_SENS_DOWNLOAD_ERROR CCDM 633 2800F012 CCDM_SENS_UNKNOWN_ERROR CCDM 634 2800F012 CNG_FRM_ACCESS_DEVICE_NOT_READY CNG 493 2800F013 CNG_FRM_ACCESS_ERROR CNG 493 2800F015 CNG_FRM_ACCESS_CONTEXT CNG 493 2800F0A0 CCDM_FRM_TRAY_METAL CCDM 634 2800F0A1 CCDM_FRM_TRAY_NOT_DISPENSED CCDM 634 2800F0A2 CCDM_FRM_TRAY_ERROR CCDM 634 2800F0A3 CCDM_FRM_SHUTTER_ERROR CCDM 634 2800F0A4 CCDM_FRM_ESCROW_EMPTY CCDM 634 2800F0A5 CCDM_FRM_ESCROW_FULL CCDM 635 2800F0A6 CCDM_FRM_ESCROW_READY CCDM 635 2800F0A7 CCDM_FRM_ESCROW_JAM CCDM 635 2800F0A8 CCDM_FRM_COMPONENT_NOT_AVAILABLE CCDM 635 2800FA11 OPL_PARITY_ERROR OPL 138 2800FA12 OPL_USER_CHARSIZE_NOT_DEFINED OPL 139 2800FA13 OPL_CODETABLE_RAM_FULL OPL 139 2800FA14 OPL_CHAR_DEFDAT_NOT_CORRECT OPL 139 2800FA15 OPL_HARDWARE_FAILURE OPL 139 2800FA16 OPL_ESC_SEQUENCE_UNKNOWN OPL 139 2800FA17 OPL_JOB_CANCELED OPL 140 2800FA20 OPL_KEYBOARD_ERROR OPL 140 29020014 CCDM_EXT_ERR_020 CCDM 639 29050001 CCDM_EXT_ERR_001 CCDM 639 29060002 CCDM_EXT_ERR_002 CCDM 639 29070003 CCDM_EXT_ERR_003 CCDM 639 29080015 CCDM_EXT_ERR_021 CCDM 639 29090018 CCDM_EXT_ERR_024 CCDM 640 290C0016 CCDM_EXT_ERR_022 CCDM 640 29110017 CCDM_EXT_ERR_023 CCDM 640 29120019 CCDM_EXT_ERR_025 CCDM 640 29130090 CCDM_EXT_ERR_144 CCDM 640 29140091 CCDM_EXT_ERR_145 CCDM 640 29150078 CCDM_EXT_ERR_120 CCDM 641 29150079 CCDM_EXT_ERR_121 CCDM 641 2915007A CCDM_EXT_ERR_122 CCDM 641 29150082 CCDM_EXT_ERR_130 CCDM 641 29160064 CCDM_EXT_ERR_100 CCDM 641 2916006C CCDM_EXT_ERR_108 CCDM 641 2916006F CCDM_EXT_EER_111 CCDM 642 29160070 CCDM_EXT_ERR_112 CCDM 642 291600B5 CCDM_EXT_ERR_181 CCDM 642

Page 737: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 729

StCode StWarn Define Device Page

29180065 CCDM_EXT_ERR_101 CCDM 642 29180066 CCDM_EXT_ERR_102 CCDM 642 29180067 CCDM_EXT_ERR_103 CCDM 642 29180069 CCDM_EXT_ERR_105 CCDM 643 2918006A CCDM_EXT_ERR_106 CCDM 643 2918006E CCDM_EXT_ERR_110 CCDM 643 29180071 CDDM_EXT_ERR_113 CCDM 643 29180072 CCDM_EXT_ERR_114 CCDM 643 29180073 CCDM_EXT_ERR_115 CCDM 643 291800C9 CCDM_EXT_ERR_201 CCDM 644 29190096 CCDM_EXT_ERR_150 CCDM 644 29190097 CCDM_EXT_ERR_151 CCDM 644 291A0074 CCDM_EXT_ERR_116 CCDM 644 291A00B4 CCDM_EXT_ERR_180 CCDM 644 291B008C CCDM_EXT_ERR_140 CCDM 644 291B008D CCDM_EXT_ERR_141 CCDM 645 291C00C8 CCDM_EXT_ERR_200 CCDM 645 291C00CA CCDM_EXT_ERR_202 CCDM 645 291C00CB CCDM_EXT_ERR_203 CCDM 645 291C00CC CCDM_EXT_ERR_204 CCDM 645 291C00CD CCDM_EXT_ERR_205 CCDM 645 291C00CE CCDM_EXT_ERR_206 CCDM 646 291E001E CCDM_EXT_ERR_030 CCDM 646 291F0028 CCDM_EXT_ERR_040 CCDM 646 291F0032 CCDM_EXT_ERR_050 CCDM 646 2920002D CCDM_EXT_ERR_045 CCDM 646 29200035 CCDM_EXT_ERR_053 CCDM 646 29210029 CCDM_EXT_ERR_041 CCDM 647 2921002A CCDM_EXT_ERR_042 CCDM 647 2921002B CCDM_EXT_ERR_043 CCDM 647 2921002C CCDM_EXT_ERR_044 CCDM 647 29210033 CCDM_EXT_ERR_051 CCDM 647 29210034 CCDM_EXT_ERR_052 CCDM 647 2922002F CCDM_EXT_ERR_047 CCDM 648 29220030 CCDM_EXT_ERR_048 CCDM 648 29220031 CCDM_EXT_ERR_049 CCDM 648 29220036 CCDM_EXT_ERR_054 CCDM 648 29220037 CCDM_EXT_ERR_055 CCDM 648 29220038 CCDM_EXT_ERR_056 CCDM 648 29280136 CCDM_EXT_ERR_310 CCDM 649 29280137 CCDM_EXT_ERR_311 CCDM 649 29280138 CCDM_EXT_ERR_312 CCDM 649 29280139 CCDM_EXT_ERR_313 CCDM 649 29280144 CCDM_EXT_ERR_324 CCDM 649 2928014D CCDM_EXT_ERR_333 CCDM 649 292801F5 CCDM_EXT_ERR_501 CCDM 650 292801F6 CCDM_EXT_ERR_502 CCDM 650 29290140 CCDM_EXT_ERR_320 CCDM 650

Page 738: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

730 June 2004

StCode StWarn Define Device Page

29290141 CCDM_EXT_ERR_321 CCDM 650 29290142 CCDM_EXT_ERR_322 CCDM 650 29290143 CCDM_EXT_ERR_323 CCDM 650 292A012D CCDM_EXT_ERR_301 CCDM 651 292B012E CCDM_EXT_ERR_302 CCDM 651 292E014C CCDM_EXT_ERR_332 CCDM 651 292E01F7 CCDM_EXT_ERR_503 CCDM 651 292E01F8 CCDM_EXT_ERR_504 CCDM 651 292F00AA CCDM_EXT_ERR_170 CCDM 651 2930014B CCDM_EXT_ERR_331 CCDM 652 29300259 CCDM_EXT_ERR_601 CCDM 652 2930025A CCDM_EXT_ERR_602 CCDM 652 2932014A CCDM_EXT_ERR_330 CCDM 652 29320192 CCDM_EXT_ERR_402 CCDM 652 29320193 CCDM_EXT_ERR_403 CCDM 652 29320194 CCDM_EXT_ERR_404 CCDM 653 29320195 CCDM_EXT_ERR_405 CCDM 653 29320196 CCDM_EXT_ERR_406 CCDM 653 29320258 CCDM_EXT_ERR_600 CCDM 653 29330190 CCDM_EXT_ERR_400 CCDM 653 29340191 CCDM_EXT_ERR_401 CCDM 653 293C0041 CCDM_EXT_ERR_065 CCDM 654 293D003D CCDM_EXT_ERR_061 CCDM 654 293E0040 CCDM_EXT_ERR_064 CCDM 654 293F003E CCDM_EXT_ERR_062 CCDM 654 293F004D CCDM_EXT_ERR_077 CCDM 654 2940003F CCDM_EXT_ERR_063 CCDM 654 2941004B CCDM_EXT_ERR_075 CCDM 655 29420044 CCDM_EXT_ERR_068 CCDM 655 29430045 CCDM_EXT_ERR_069 CCDM 655 29440043 CCDM_EXT_ERR_067 CCDM 655 29450042 CCDM_EXT_ERR_066 CCDM 655 29460047 CCDM_EXT_ERR_071 CCDM 655 29470046 CCDM_EXT_ERR_070 CCDM 656 29480048 CCDM_EXT_ERR_072 CCDM 656 2949004C CCDM_EXT_ERR_076 CCDM 656 294A0049 CCDM_EXT_ERR_073 CCDM 656 294B004A CCDM_EXT_ERR_074 CCDM 656 29500050 CCDM_EXT_ERR_080 CCDM 656 29510051 CCDM_EXT_ERR_081 CCDM 657 29520052 CCDM_EXT_ERR_082 CCDM 657 29530053 CCDM_EXT_ERR_083 CCDM 657 29540054 CCDM_EXT_ERR_084 CCDM 657 29550055 CCDM_EXT_ERR_085 CCDM 657 295A025B CCDM_EXT_ERR_603 CCDM 657 295A025C CCDM_EXT_ERR_604 CCDM 658 295A025E CCDM_EXT_ERR_606 CCDM 658 295A0261 CCDM_EXT_ERR_609 CCDM 658

Page 739: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 731

StCode StWarn Define Device Page

295A0264 CCDM_EXT_ERR_612 CCDM 658 295B0266 CCDM_EXT_ERR_614 CCDM 658 295B026A CCDM_EXT_ERR_618 CCDM 658 295C0260 CCDM_EXT_ERR_608 CCDM 659 295C0262 CCDM_EXT_ERR_610 CCDM 659 295D0267 CCDM_EXT_ERR_615 CCDM 659 295E0263 CCDM_EXT_ERR_611 CCDM 659 295E0265 CCDM_EXT_ERR_613 CCDM 659 295F0268 CCDM_EXT_ERR_616 CCDM 659 2960025D CCDM_EXT_ERR_605 CCDM 660 2960025F CCDM_EXT_ERR_607 CCDM 660 29600269 CCDM_EXT_ERR_617 CCDM 660 8001 NEW_LKEY PIN 131 8002 NEW_SYNC PIN 131 E0000001 USBIO_ERR_CRC USB 65 E0000002 USBIO_ERR_BTSTUFF USB 65 E0000003 USBIO_ERR_DATA_TOGGLE_MISMATCH USB 65 E0000004 USBIO_ERR_STALL_PID USB 65 E0000005 USBIO_ERR_DEV_NOT_RESPONDING USB 65 E0000006 USBIO_ERR_PID_CHECK_FAILURE USB 66 E0000007 USBIO_ERR_UNEXPECTED_PID USB 66 E0000008 USBIO_ERR_DATA_OVERRUN USB 66 E0000009 USBIO_ERR_DATA_UNDERRUN USB 66 E000000A USBIO_ERR_RESERVED1 USB 66 E000000B USBIO_ERR_RESERVED2 USB 66 E000000C USBIO_ERR_BUFFER_OVERRUN USB 67 E000000D USBIO_ERR_BUFFER_UNDERRUN USB 67 E000000F USBIO_ERR_NOT_ACCESSED USB 67 E0000010 USBIO_ERR_FIFO USB 67 E0000011 USBIO_ERR_XACT_ERROR USB 67 E0000012 USBIO_ERR_BABBLE_DETECTED USB 67 E0000013 USBIO_ERR_DATA_BUFFER_ERROR USB 68 E0000030 USBIO_ERR_ENDPOINT_HALTED USB 68 E0000100 USBIO_ERR_NO_MEMORY USB 68 E0000200 USBIO_ERR_INVALID_URB_FUNCTION USB 68 E0000300 USBIO_ERR_INVALID_PARAMETER USB 68 E0000400 USBIO_ERR_ERROR_BUSY USB 69 E0000500 USBIO_ERR_REQUEST_FAILED USB 69 E0000600 USBIO_ERR_INVALID_PIPE_HANDLE USB 69 E0000700 USBIO_ERR_NO_BANDWIDTH USB 69 E0000800 USBIO_ERR_INTERNAL_HC_ERROR USB 69 E0000900 USBIO_ERR_ERROR_SHORT_TRANSFER USB 69 E0000A00 USBIO_ERR_BAD_START_FRAME USB 70 E0000B00 USBIO_ERR_ISOCH_REQUEST_FAILED USB 70 E0000C00 USBIO_ERR_FRAME_CONTROL_OWNED USB 70 E0000D00 USBIO_ERR_FRAME_CONTROL_NOT_OWNED USB 70 E0000E00 USBIO_ERR_NOT_SUPPORTED USB 70 E0000F00 USBIO_ERR_INVALID_CONFIGURATION_DESCRIPTOR USB 70

Page 740: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

732 June 2004

StCode StWarn Define Device Page

E0001000 USBIO_ERR_FAILED USB 71 E0001001 USBIO_ERR_INVALID_INBUFFER USB 71 E0001002 USBIO_ERR_INVALID_OUTBUFFER USB 71 E0001003 USBIO_ERR_OUT_OF_MEMORY USB 71 E0001004 USBIO_ERR_PENDING_REQUESTS USB 71 E0001005 USBIO_ERR_ALREADY_CONFIGURED USB 72 E0001006 USBIO_ERR_NOT_CONFIGURED USB 72 E0001007 USBIO_ERR_OPEN_PIPES USB 72 E0001008 USBIO_ERR_ALREADY_BOUND USB 72 E0001009 USBIO_ERR_NOT_BOUND USB 72 E000100A USBIO_ERR_DEVICE_NOT_PRESENT USB 73 E000100B USBIO_ERR_CONTROL_NOT_SUPPORTED USB 73 E000100C USBIO_ERR_TIMEOUT USB 73 E000100D USBIO_ERR_INVALID_RECIPIENT USB 73 E000100E USBIO_ERR_INVALID_TYPE USB 73 E000100F USBIO_ERR_INVALID_IOCTL USB 74 E0001010 USBIO_ERR_INVALID_DIRECTION USB 74 E0001011 USBIO_ERR_TOO_MUCH_ISO_PACKETS USB 74 E0001012 USBIO_ERR_POOL_EMPTY USB 74 E0001013 USBIO_ERR_PIPE_NOT_FOUND USB 74 E0001014 USBIO_ERR_INVALID_ISO_PACKET USB 75 E0001015 USBIO_ERR_OUT_OF_ADDRESS_SPACE USB 75 E0001016 USBIO_ERR_INTERFACE_NOT_FOUND USB 75 E0001017 USBIO_ERR_INVALID_DEVICE_STATE USB 75 E0001018 USBIO_ERR_INVALID_PARAM USB 75 E0001019 USBIO_ERR_DEMO_EXPIRED USB 76 E000101A USBIO_ERR_INVALID_POWER_STATE USB 76 E000101B USBIO_ERR_POWER_DOWN USB 76 E000101C USBIO_ERR_VERSION_MISMATCH USB 76 E000101D USBIO_ERR_SET_CONFIGURATION_FAILED USB 77 E0001080 USBIO_ERR_VID_RESTRICTION USB 77 E0001081 USBIO_ERR_ISO_RESTRICTION USB 77 E0001082 USBIO_ERR_BULK_RESTRICTION USB 77 E0001083 USBIO_ERR_EP0_RESTRICTION USB 77 E0001084 USBIO_ERR_PIPE_RESTRICTION USB 78 E0001085 USBIO_ERR_PIPE_SIZE_RESTRICTION USB 78 E0001086 USBIO_ERR_CONTROL_RESTRICTION USB 78 E0001087 USBIO_ERR_INTERRUPT_RESTRICTION USB 78 E0001100 USBIO_ERR_DEVICE_NOT_FOUND USB 78 E0001102 USBIO_ERR_DEVICE_NOT_OPEN USB 79 E0001104 USBIO_ERR_NO_SUCH_DEVICE_INSTANCE USB 79 E0001105 USBIO_ERR_INVALID_FUNCTION_PARAM USB 79 E0001106 USBIO_ERR_LOAD_SETUP_API_FAILED USB 79 E0002000 USBIO_ERR_SET_CONFIG_FAILED USB 79 E0003000 USBIO_ERR_USBD_BUFFER_TOO_SMALL USB 80 E0004000 USBIO_ERR_USBD_INTERFACE_NOT_FOUND USB 80 E0005000 USBIO_ERR_INVALID_PIPE_FLAGS USB 80 E0006000 USBIO_ERR_USBD_TIMEOUT USB 80

Page 741: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 733

StCode StWarn Define Device Page

E0007000 USBIO_ERR_DEVICE_GONE USB 80 E0008000 USBIO_ERR_STATUS_NOT_MAPPED USB 80 E0010000 USBIO_ERR_CANCELED USB 81 E0020000 USBIO_ERR_ISO_NOT_ACCESSED_BY_HW USB 81 E0030000 USBIO_ERR_ISO_TD_ERROR USB 81 E0040000 USBIO_ERR_ISO_NA_LATE_USBPORT USB 81 E0050000 USBIO_ERR_ISO_NOT_ACCESSED_LATE USB 81 E0400001 LMND9G_PAPER_END LMND9G 301 E0400002 LMND9G_DEVICE LMND9G 301 E0400003 LMND9G_JAM LMND9G 301 E0400004 LMND9G_MEMORY LMND9G 302 E0400005 LMND9G_CMD LMND9G 302 E0400006 LMND9G_PARITY LMND9G 302 E0400007 LMND9G_CMD_LOST LMND9G 302 E0400009 LMND9G_MARK LMND9G 302 E040000A LMND9G_CHECKSUM LMND9G 302 E040000B LMND9G_FW LMND9G 303 E040000D LMND9G_INVALID_DATA LMND9G 303 E040000E LMND9G_WRITE_TIMEOUT LMND9G 303 E040000F LMND9G_READ_TIMEOUT LMND9G 303 E0400010 LMND9G_WAIT_FOR_NEXT_JOB LMND9G 303 E0400011 LMND9G_LINE_PARAMETER LMND9G 304 E0400012 LMND9G_INT_ERROR LMND9G 304 E0410001 LMTH21_PAPER_END LMTH21 305 E0410002 LMTH21_COVER LMTH21 305 E0410003 LMTH21_HEAD LMTH21 305 E0410004 LMTH21_VOLTAGE LMTH21 306 E0410005 LMTH21_JAM LMTH21 306 E0410006 LMTH21_CUTTER LMTH21 306 E0410007 LMTH21_MEMORY LMTH21 306 E0410008 LMTH21_INVALID_DATA LMTH21 306 E0410009 LMTH21_WRITE_TIMEOUT LMTH21 307 E041000A LMTH21_READ_TIMEOUT LMTH21 307 E041000B LMTH21_WAIT_FOR_NEXT_JOB LMTH21 307 E041000C LMTH21_LINE_PARAMETER LMTH21 307 E041000D LMTH21_MARK LMTH21 307 E0420001 LM_INSUFFICIENT_BUFFER PRN(FRAME) 293 E0420002 LM_INVALID_REGISTRY_PARAMETER PRN(FRAME) 293 E0420003 LM_INVALID_FUNCTION PRN(FRAME) 293 E0420004 LM_INTERNAL_ERROR PRN(FRAME) 293 E0420005 LM_FUNCTION_NOT_ALLOWED PRN(FRAME) 294 E0420006 LM_WRITE_ERROR PRN(FRAME) 294 E0420007 LM_SYSTEM_ERROR PRN(FRAME) 294 E0420008 LM_UNEXPECTED_PARAMETER PRN(FRAME) 294 E0420009 LM_OPEN_ERROR PRN(FRAME) 294 E042000A LM_JOB_START_FAILED PRN(FRAME) 294 E042000B LM_PORT_BUSY PRN(FRAME) 295 E042000D LM_SRV_INVALID_PARAMETER PRN(FRAME) 295

Page 742: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

734 June 2004

StCode StWarn Define Device Page

E042000E LM_SRV_ALREADY_REGISTERED PRN(FRAME) 295 E042000F LM_SRV_ALREADY_CLAIMED PRN(FRAME) 295 E0420010 LM_SRV_INVALID_CLIENT_HANDLE PRN(FRAME) 295 E0420011 LM_SRV_NOT_REGISTERED PRN(FRAME) 295 E0420012 LM_SRV_START PRN(FRAME) 296 E0420013 LM_SRV_PRINTER_NOT_FOUND PRN(FRAME) 296 E0420014 LM_SRV_ACCESS_DENIED PRN(FRAME) 296 E0420015 LM_SRV_ACCESS_LOCKED PRN(FRAME) 296 E0420016 LM_UNKNOWN_PROPERTY PRN(FRAME) 296 E0420017 LM_PROPERTY_FORMAT_ERROR PRN(FRAME) 296 E0420018 LM_INVALID_PROPERTY PRN(FRAME) 297 E0420019 LM_INVALID_STRING PRN(FRAME) 297 E0440001 LMTP07_PAPER_END LMTP07 319 E0440002 LMTP07_CUTTER_JAM LMTP07 319 E0440003 LMTP07_MARK LMTP07 319 E0440004 LMTP07_PRESENTER_JAM LMTP07 320 E0440005 LMTP07_RETRACTOR_JAM LMTP07 320 E0440006 LMTP07_JAM LMTP07 320 E0440007 LMTP07_JOB_TIMEOUT LMTP07 320 E0440008 LMTP07_HIGH_VOLTAGE LMTP07 320 E0440009 LMTP07_LOW_VOLTAGE LMTP07 321 E044000A LMTP07_HEAD LMTP07 321 E044000B LMTP07_TYPE LMTP07 321 E0440010 LMTP07_INVALID_DATA LMTP07 321 E0440011 LMTP07_WRITE_TIMEOUT LMTP07 321 E0440012 LMTP07_READ_TIMEOUT LMTP07 322 E0440013 LMTP07_WAIT_FOR_NEXT_JOB LMTP07 322 E0440015 LMTP07_INT_ERROR LMTP07 322 E0440016 LMTP07_OFFLINE_ERROR LMTP07 322 E0460001 LMTH5X_PAPER_END LMTH5X 313 E0460002 LMTH5X_PAPER_INIT_REQUIRED LMTH5X 313 E0460003 LMTH5X_PAPER_JAM LMTH5X 313 E0460005 LMTH5X_MARK_NOT_FOUND LMTH5X 314 E0460006 LMTH5X_WRONG_MARK_POSITION LMTH5X 314 E0460007 LMTH5X_MAX_LENGTH_EXCEEDING LMTH5X 314 E046000A LMTH5X_CUTTER_OPEN LMTH5X 314 E046000D LMTH5X_CUTTER_ERROR LMTH5X 315 E046000E LMTH5X_WRONG_CUTTER_POSITION LMTH5X 315 E0460011 LMTH5X_JOB_CANCELLED LMTH5X 315 E0460012 LMTH5X_DRAWOFF_TIMEOUT LMTH5X 315 E0460013 LMTH5X_PRINT_TIMEOUT LMTH5X 316 E0460015 LMTH5X_NOT_CONNECTED LMTH5X 316 E0460016 LMTH5X_INVALID_DATA LMTH5X 316 E0460017 LMTH5X_WRITE_FAULT LMTH5X 316 E0460018 LMTH5X_READ_FAULT LMTH5X 317 E0460019 LMTH5X_READ_TIMEOUT LMTH5X 317 E046001E LMTH5X_FRM_ERROR LMTH5X 317 E046001F LMTH5X_INVALID_COMMAND LMTH5X 317

Page 743: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Numeric list of all messages

June 2004 735

StCode StWarn Define Device Page

E0470001 LDTH5X_SECTION_NOT_FOUND LDTH5X 309 E0470002 LDTH5X_FW_FILE_NOT_SPECIFIED LDTH5X 309 E0470003 LDTH5X_CANNOT_OPEN_FRM_FILE LDTH5X 309 E0470004 LDTH5X_INVALID_FW_FILE LDTH5X 309 E0470005 LDTH5X_INVALID_FW_ID LDTH5X 310 E0470006 LDTH5X_CANNOT_OPEN_PRINTER LDTH5X 310 E0470007 LDTH5X_CANNOT_CLAIM_PRINTER LDTH5X 310 E0470008 LDTH5X_NO_MEMORY LDTH5X 310 E0470015 LDTH5X_NOT_CONNECTED LDTH5X 310 E0470016 LDTH5X_INVALID_DATA LDTH5X 310 E0470017 LDTH5X_WRITE_FAULT LDTH5X 311 E0470018 LDTH5X_READ_FAULT LDTH5X 311 E0470019 LDTH5X_READ_TIMEOUT LDTH5X 311 E8001000 USBIO_ERR_INSUFFICIENT_RESOURCES USB 82

Windows error codes Define Device

0000.0001 - 1FFF.FFFF ERROR_... all

Information to these messages can be indicated with the program CSCHELP.

Page 744: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

736 June 2004

Page 745: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

June 2004

Notes

Page 746: System Messages - SUNIC Messages CSC-W32 V2.0_53… · This manual is intended for programmers, technicians and system operators. It provides a complete overview of all system messages

Published by Wincor Nixdorf International GmbH 33094 Paderborn Germany

Printed in Germany Order No.: June 2004


Recommended