26
Transcript
  • Contents

    External and internal tight cabinets, heating and cooling systems

    IP55 outdoor distribution cabinets

    Underground plinths for single-and double-jacket distribution cabinets

    MFG outdoor telecommunications cabinets

    Positioning of outdoor telecommunications cabinet type MFG IP55

    Heating and cooling systems for external and internal distribution cabinets

    Internal industrial cabinets IP54, accessories

    Heating and cooling systems for internal industrial cabinets

    Environmental Condition Monitoring System

    External street distribution cabinets

    IP protection

    Outdoor FTTx Cabinets

    Certificates

    Realizations

    The assembly of a modern and universal access system based on outdoor BKT Elektronik distribution cabinets is possible

    thanks to the application of cutting - edge solutions in compliance with Polish as well as international telecommunication

    standards.

    Outdoor cabinets constitute a protection of passive and active devices mounted inside in every weather condition.

    Double-wall structure protects against heat, cold, rain, snow, as well as not permitted access. Due to its IK10 impact rating,

    the structure also protects against mechanical damage. Their ingress protection has been rated to IP55. The cabinets are

    made of 2 mm aluminum sheet and are coated with outdoor paint. They are estimated to be usable for 30 years as a result

    of tests conducted in an independent research lab.

    1

    1-4

    5

    5

    6

    6-7

    8-9

    10-11

    12-13

    14

    15

    16

    17

    18-22

  • External and internal tight cabinets, heating and cooling systems

    Protection of equipment against changeable whether conditions and against acts of vandalism and theft is a very important issue. External and internal cabinets are fitted both

    in generally available places and places with an adverse effect and must provide protection for the equipment inside.

    BKT cabinets are designed and made to meet all relevant requirements for cabinets to be placed inside and on the outside of buildings.

    Requirements to be met by external casing are contained in the following standards:

    ź Series of environmental tests for environmental conditions as per PN-ETSI EN 300 019-1-4, class 4.1 for cold tests Ae - PN-EN 60068-2-1:2007 and dry heat Be - PN-

    EN 60068-2-2:2007, Be sample.

    ź Simulated solar radiation at ground level and guidance for solar radiation testing – PN-EN 60068-2-5;

    ź Acoustic tests - PN-EN-ISO 11200;

    ź Vibration tests - PN-EN 60068-2-6;

    ź Mechanical resistance tests – PN-EN 60439-5;

    ź IP rating (degree of protection) – PN-EN 60529.

    Cabinets are made to standards specified in the following certificates:

    ź ISO 9001:2008

    ź ISO 14001:2004

    ź EN ISO 15085-2

    ź EN ISO 3834-2

    Application of EU standards compliant procedures in the making of the structures as reflected in ISO certificates results in the external casing having a long life of up to 30 years

    as confirmed by the independent Testing Laboratory.

    IP55 external distribution cabinets

    1

    The changeable environmental conditions affecting adversely the electronics require that casing manufacturers use corrosion resistant materials and ensure appropriate

    rating (IP55) providing protection against dust or liquid penetration, unauthorised entry or mechanical damage (IK10).

    External distribution cabinets are made of aluminium sheet metal with standard RAL7035 coating; they have a double wall (air insulation) ensuring free air flow in the space.

    BKT external cabinets come as a standard with:

    ź 3 - or 4 - point locking system (bolting), depending on the height;

    ź Transitional spacer base with a height of 50 mm as a middle point between the underground base and the cabinet;

    ź Cable glands at the cabinet bottom;

    ź Vertical assembly sections;

    ź Assembly panel in DASZ - P models;

    ź Earth strip;

    ź Assembly holders on the roof;

    ź Door opening stop

    There are two BKT external cabinet families depending on the type of fabrication.

  • IP55 external distribution cabinets

    2

    Heating of cabinet via heater with thermo

    ventilator.

  • Outdoor distribution cabinets IP55

    3

    Construction features:

    ź A structure consisting of a single wall made of an aluminium sheet painted to RAL7035 with paint for outdoor use;

    ź A door designed in the double-wall technology;

    ź A removable rear wall, an external and internal roof;

    ź A polyurethane gasket poured on the internal door panel, the rear wall and the internal roof;

    ź A 3-point locking system

    Equipment:

    ź Vertical 19” assembly sections – one set (right and left) per each chamber

    ź A foam cable gland unit mounted in the floor – one per each chamber

    ź A copper earth strip – all components of the cabinet are electrically concentrated in one point for the earth strip

    ź A 19” 1U bracket in the floor and on the side walls, e.g. for mounting a power strip

    ź A door stop

    ź A door opening sensor bracket

    ź A handle with insert, code 1333

    ź Transport lugs in the internal roof

    ź TH 35 mm strips for mounting, e.g. heaters

    ź Plugs in the internal roof for mounting a ventilation system (fan and filtration grill)

    ź A punched barrier separating cabinet chambers (for two-chamber cabinets)

    NameWidth

    (mm)

    Index

    RAL7035

    IP

    degree

    800 450 110A1600 IP55 Outdoor cabinet BKT 19” 15U (aluminium, single-wall, single-chamber, single-door)

    Depth

    (mm)

    885

    Height

    (mm)

    800 450 110A1601 IP55 Outdoor cabinet BKT 19” 22U (aluminium, single-wall, single-chamber, single-door) 1195

    1200 450 110A1602IP55 Outdoor cabinet BKT 19” 22U (aluminium, single-wall, double-chamber, double-door) 1195

    Single-wall cabinets:

    Outdoor distribution cabinets IP55 – single wall

    800 800 110A1603IP55 Outdoor cabinet BKT 19” 22U (aluminium, single-wall, single-chamber, single-door) 1195

    1200 800 110A1604IP55 Outdoor cabinet BKT 19” 22U (aluminium, single-wall, double-chamber, double-door) 1195

    800 450 110A1605IP55 Outdoor cabinet BKT 19” 30U (aluminium, single-wall, single-chamber, single-door) 1555

    1200 450 110A1606IP55 Outdoor cabinet BKT 19” 30U (aluminium, single-wall, double-chamber, double-door) 1555

    800 800 110A1607IP55 Outdoor cabinet BKT 19” 30U (aluminium, single-wall, single-chamber, single-door) 1555

    1200 800 110A1608IP55 Outdoor cabinet BKT 19” 30U (aluminium, single-wall, double-chamber, double-door) 1555

    800 800 110A1609IP55 Outdoor cabinet BKT 19” 35U (aluminium, single-wall, single-chamber, single-door) 1775

  • Outdoor distribution cabinets IP55

    4

    Outdoor distribution cabinets IP55 – double wall

    Construction features:

    ź A structure consisting of a single wall made of an aluminium sheet painted to RAL7035 with paint for outdoor use;

    ź A door designed in the double-wall technology;

    ź A removable rear wall, an external and internal roof;

    ź A polyurethane gasket poured on the internal door panel, the rear wall and the internal roof;

    ź A 3-point locking system;

    Equipment:

    ź Vertical 19” assembly sections – one set (right and left) per each chamber

    ź A foam cable gland unit mounted in the floor – one per each chamber

    ź A copper earth strip – all components of the cabinet are electrically concentrated in one point for the earth strip

    ź A 19” 1U bracket in the floor and on the side walls, e.g. for mounting a power strip

    ź A door stop

    ź A door opening sensor bracket

    ź A handle with insert, code 1333

    ź Transport lugs in the internal roof

    ź TH 35 mm strips for mounting, e.g. heaters

    ź Plugs in the internal roof for mounting a ventilation system (fan and filtration grill)

    ź A punched barrier separating cabinet chambers (for two-chamber cabinets)

    Double-wall cabinets:

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    Outdoor cabinet BKT 19” 15U (aluminium, double-wall, single-chamber, single-door) 15U 110A1500800 450

    Outdoor cabinet BKT 19” 22U (aluminium, double-wall, single-chamber, single-door) 22U 110A1501800 450

    Outdoor cabinet BKT 19” 22U (aluminium, double-wall, double-chamber, double-door) 22U 110A15021200 450

    Outdoor cabinet BKT 19” 22U (aluminium, double-wall, single-chamber, single-door) 22U 110A1503800 800

    Outdoor cabinet BKT 19” 22U (aluminium, double-wall, double-chamber, double-door) 22U 110A15041200 800

    Outdoor cabinet BKT 19” 30U (aluminium, double-wall, single-chamber, single-door) 30U 110A1505800 450

    Outdoor cabinet BKT 19” 30U (aluminium, double-wall, double-chamber, double-door) 30U 110A15061200 450

    Outdoor cabinet BKT 19” 30U (aluminium, double-wall, single-chamber, single-door) 30U 110A1507800 800

    Outdoor cabinet BKT 19” 30U (aluminium, double-wall, double-chamber, double-door) 30U 110A15081200 800

    Outdoor cabinet BKT 19” 35U (aluminium, double-wall, single-chamber, single-door) 35U 110A1509800 800

    IP

    degree

    IP55

    IP55

    IP55

    IP55

    IP55

    IP55

    IP55

    IP55

    IP55

    IP55

  • Underground plinths for single-and double-jacket distribution cabinets

    5

    For the purpose of permanent installation of an outdoor cabinet in the ground, BKT offers bases adopted to each type of a cabinet. The line of bases matches both single- and

    double-shell cabinets of the same outer dimensions (width/depth).

    Construction features:

    ź A structure made of a stainless steel sheet painted to RAL7035 with paint for outdoor use

    ź The base features 4 extendable feet for levelling the base before filling

    ź There is a bracket inside the base for mounting (fixing) pipes or cables led to the cabinet;

    the bracket corresponds to the location of the foam cable gland unit in the cabinet floor.

    Available models:

    MFG outdoor telecommunications cabinets

    MFG series cabinets are applied when designing telecommunications networks serving as via points between a service provider and a customer.

    Construction features:

    ź A structure consists of a double-wall made of an aluminium sheet painted to RAL7038 with paint for outdoor use;

    ź A polyurethane gasket is poured on the internal door panel;

    ź A 3-point locking system;

    ź A removable internal roof for mounting, e.g. air-air heat exchangers or a ventilation system (fan and ventilation grill);

    ź A punched barrier separating cabinet chambers (for MFG12 and MFG18 cabinets);

    ź A battery compartment is located under the chambers.

    NameWidth

    (mm)

    Index

    RAL7038

    IP

    degree

    1000 500 110A8000IP55 BKT MFG 19" outdoor cabinet type 8, 22U (single-chamber, single-door)

    Depth

    (mm)

    1500

    Height

    (mm)

    1300 500 110A8001IP55 BKT MFG 19" outdoor cabinet type 12, 22U (double-chamber, double-door) 1500

    2000 500 110A8002IP55 BKT MFG 19" outdoor cabinet type 18, 22U (triple- chamber, triple-door) 1500

    Available models:

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    Underground plinth BKT (steel-hot-dip galvanised) 15U 110A4000800 450

    Underground plinth BKT (steel-hot-dip galvanised) 22U 110A4001800 450

    Underground plinth BKT (steel-hot-dip galvanised) 22U 110A40021200 450

    Underground plinth BKT (steel-hot-dip galvanised) 22U 110A4003800 800

  • Heating and cooling systems for external and internal

    distribution cabinets

    Hygrotherm BKT ETF 012

    (6A, 250V-NC, 0°C/60°C)

    Heater BKT 400 CSL-028-400W/230VAC

    Thermostat BKT TRT-10A230V-NC,

    -10°C/+80°C for heaters

    Thermostat BKT TRT-10A230VAC-NO,

    -10°C/+80°C for fans

    Fan with a filter BKT RAL7032 FPF08KR230BE-110

    Index: 10352148

    Index: 10352119

    Index: 10352167Index: 110A9300

    Index: 10352125

    Positioning of outdoor telecommunications cabinet type MFG IP55

    Available models:

    A series of bases provided for MFG cabinets serving as a perfect component for their permanent installation in the ground. Each MFG series cabinet has its corresponding base

    of a specific size.

    Construction features:

    ź A structure made of a stainless steel sheet painted to RAL7038 with paint for outdoor use;

    ź The base features 4 extendable feet for levelling the base before filling;

    ź There is a bracket inside the base for mounting (fixing) pipes or cables led to the cabinet

    and a space provided for connection of an earthing conductor.

    NameWidth

    (mm)

    Index

    RAL7038

    Depth

    (mm)

    Height

    (mm)

    BKT underground plinth for MFG cabinet type 8 ok.700 110A81001000 500

    BKT underground plinth for MFG cabinet type 12 ok.700 110A81011300 500

    BKT underground plinth for MFG cabinet type 18 ok.700 110A8102800 500

    Environmental conditions have a significant influence on the operation of devices installed in the cabinet. Therefore, BKT offers ventilation systems, air conditioners and

    heaters necessary to heat the cabinet chamber in colder periods and to cool the devices down (in periods of increased temperatures) to a safe temperature, i.e. to the max

    operating temperature of a given device specified in technical documentation of the product, depending on total power losses of these devices.

    The cooling system installed in the cabinet is intended to control the rotation speed of the fans in an intelligent way with respect to variable temperatures inside the cabinet.

    The rotation speed of the fans can be programmed depending on the preset temperature in the cabinet. A variable rotation speed contributes also to lower energy

    consumption and reduces a noise emission within the cabinet.

    The system consists of the following components:

    ź 48VDC fan, pumped air capacity of 350m³/h – 2 pcs

    ź Power pack 230V/48VDC – pc

    ź Fan operation controller with temperature sensor - pc

    ź Aluminium mounting elements for the fans

    ź Aluminium grills with filter mats

    ź Cable bundles for system connection and mounting screws

    When ordering the above ventilation system, specify the model of a cabinet

    in which it will be installed.

    6

    Cooling system two fans

  • Heating and cooling systems for external and internal

    distribution cabinets

    Available models:

    Working temperature range for external air conditioners: -20°C - 55°C, air conditioners available in RAL7035

    NameWidth

    (mm) Index

    Weight

    (kg)

    Depth

    (mm)

    Height

    (mm)

    Air conditioner BKT EMO04

    (230V, 50-60Hz, 380W) IP54 - side 460 17 110A9100285 180

    Cooling power

    (W)

    380

    Noise level

    (dB)

    60

    Air conditioner BKT EMO06

    (230V, 50-60Hz, 640W) IP54 - side 606 21 110A9101316 212 640 65

    Air conditioner BKT EMO08

    (230V, 50-60Hz, 820W) IP54 - side 783 27 110A9103348 215 820 65

    Air conditioner BKT EMO10

    (230V, 50-60Hz, 1000W) IP54 - side 783 28 110A9105348 215 1000 65

    Air conditioner BKT EMO12

    (230V, 50-60Hz, 1250W) IP54 - side 999 38 110A9107405 237 1250 65

    Air conditioner BKT EMO16

    (230V, 50-60Hz, 1600W) IP54 - side 999 40 110A9109405 237 1600 65

    Air conditioner BKT EMO20

    (230V, 50-60Hz, 2000W) IP54 - side 999 52 110A9111406 237 2000 65

    Air conditioner BKT EMO30

    (230V, 50-60Hz, 2900W) IP54 - side 1270 80 110A9113500 336 2900 70

    Air conditioner BKT EMO40

    (230V, 50-60Hz, 3850W) IP54 - side 1270 82 110A9115500 336 3850 70

    Air conditioner BKT EMO60

    (400V, 3~50Hz, 5800W) IP54 - side 2000 150 110A9117600 380 5800 72

    Air conditioner BKT EMO80

    (400V, 3~50Hz, 7600W) IP54 - side 2000 160 110A9119800 380 7600 75

    Air conditioner BKTEMOA0

    (400V, 3~50Hz, 9400W) IP54 - side 2000 180 110A9121800 380 9400 77

    7

  • Internal industrial cabinets IP54, accessories

    BKT-IP54

    Available models 42U door front/rear: metal sheet

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2610600 600

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2611600 800

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2612600 1000

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2613800 600

    IP

    degree

    IP54

    IP54

    IP54

    IP54

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2614800 800 IP54

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2615800 1000 IP54

    Available models 42U door front/rear: metal

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2710600 600

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2711600 800

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2712600 1000

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2713800 600

    IP

    degree

    IP54

    IP54

    IP54

    IP54

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2714800 800 IP54

    BKT industrial rack cabinet, 19” 42U

    (front/back door: metal sheet/glass, steel profile), without one side wall 2086 110A2715800 1000 IP54

    Available models of walls for cabinets 42U

    NameIndex

    RAL7035

    Depth

    (mm)

    Side wall for industrial cabinet BKT 42U,

    with mounting screws 110A5244600

    Side wall for industrial cabinet BKT 42U,

    with mounting screws 110A5245800

    Side wall for industrial cabinet BKT 42U,

    with mounting screws 110A52461000

    8

    Expected operating conditions of devices make manufacturers of enclosures increase technological and performance requirements. Indoor BKT IP54 industrial cabinets were

    designed to firmly secure their internal equipment. In many cases, locations of the cabinets arranged by the designers include very dusty places and production halls with

    unfavourable operating conditions which affect electronic components. Wherever it is not possible to air-condition rooms or install volume extinguishing systems, e.g. in

    historical sites – the conditions are imposed by a restorer – indoor BKT industrial cabinets of IP55 protection degree fit perfectly. With their tightness performance of IP55, it is

    possible to install air-conditioners and extinguishers which form a perfect product protecting equipment mounted in it. It is a cost-efficient solution meeting customers’

    demands.

    Standard equipment of 32U and 42U cabinets

    ź Two sets of 19” 42U mounting profiles

    ź Removable sectional floor with a foam-sealed cable penetration

    ź Three-point lock

    ź Handles with inserts, code 1333

    ź One side wall included (second wall: optional accessory)

    ź 100mm tall pedestal with knock-out cable penetration blanks

    ź Max. static load : 1500kg

    ź Left or right-hand door installation with cabinet installation in rows

    ź Roof with blanc for a foam-sealed cable penetration and lifting lug installation

    ź Door opening angle: ca. 270°

    ź All parts electrically bonded

    Structural features of 32U and 42U cabinets

    ź Galvanised steel sheet

    ź Steel section frame

    ź Metal sheet/glass front/back door

    ź Two component polyurethane gasket (hot melt foamed-in-place)

    ź RAL7035 colour

    ź IP54 protection degree

  • Internal industrial cabinets IP54, accessories

    Available models 32U door front/rear: metal sheet/glass

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2600600 600

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2601600 800

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2602600 1000

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2603800 600

    IP

    degree

    IP54

    IP54

    IP54

    IP54

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2604800 800 IP54

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet/glass, steel profile), without one side wall 1641 110A2605800 1000 IP54

    Available models 32U door front/rear: metal sheet

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2700600 600

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2701600 800

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2702600 1000

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2703800 600

    IP

    degree

    IP54

    IP54

    IP54

    IP54

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2704800 800 IP54

    BKT industrial rack cabinet, 19” 32U

    (front/back door: metal sheet, steel profile), without one side wall 1641 110A2705800 1000 IP54

    Available models of walls for cabinets 32U

    NameIndex

    RAL7035

    Depth

    (mm)

    Side wall for industrial cabinet BKT 32U, with mounting screws 110A5241600

    Side wall for industrial cabinet BKT 32U, with mounting screws 110A5242800

    Side wall for industrial cabinet BKT 32U, with mounting screws 110A52431000

    As a standard, BKT indoor industrial cabinets are delivered without one wall. This results from individual needs of our customers who, in many cases, require a wall designed with

    special reinforcement and openings necessary to mount an air-conditioner or filtration grills with fans responsible for cooling devices installed in the cabinet. Walls for

    installation of an air-conditioner are customised to individual cooling demands of the cabinet. If the customer requires a cabinet without an air-conditioner, the wall needs to be

    ordered separately.

    9

  • Heating and cooling systems for internal industrial cabinets

    Available models:

    Index: 10352148

    Index: 10352119

    Index: 10352167

    Index: 110A9300

    Index: 10352125

    Thermostat BKT TRT-10A230VAC-NO, -10ºC/+80ºC for fans Thermostat BKT TRT-10A230V-NC, -10ºC/+80ºC for heaters

    Fan with a filter BKT RAL7032 FPF08KR230BE-110

    Electronic hygotherm BKT ETF 012 (6A,250V-NC , 0ºC/60ºC) Heater BKT 400 CSL-028-400W/230VAC

    As cabinets are installed in various places and with different equipment fitted inside, stable ambient conditions inside the cabinet must be ensured. For this purpose, we offer

    systems for heating and cooling the inside of the cabinet. The heating system consists of heaters with air flow controlled with a thermostat or hygrostat; cooling is performed

    with air conditioners. Air conditioners are to be selected taking into account the power of equipment fitted inside the cabinet. Make sure that the power of an air conditioner is

    not more than 20% of the total power of the equipment provided inside the cabinet.

    10

  • Heating and cooling systems for internal industrial cabinets

    Available models:

    Working temperature range of air conditioners used for internal applications: -20°C – 55°C, air conditioners available in RAL7035

    Air conditioners are part of a precision cooling system. Appropriate power of an air conditioner compared to the total power loss of the equipment inside the cabinet will

    ensure trouble-free operation and an optimum temperature of 35°C inside the cabinet (default setting).

    NameWidth

    (mm) IndexWeight

    (kg)

    Depth

    (mm)

    Height

    (mm)

    Air conditioner BKT EGOS3

    (230V, 50-60Hz, 300W) - side 340 14 110A9024585 125

    Cooling power

    (W)

    300

    Noise level

    (dB)

    61

    Air conditioner BKT EGO04

    (230V, 50-60Hz, 380W) - side 450 17 110A9000285 176 380 60

    Air conditioner BKT EGO06

    (230V, 50-60Hz, 640W) - side 605 21 110A9001306 209 640 65

    Air conditioner BKT EGO08

    (230V, 50-60Hz, 820W) - side 783 27 110A9003348 213 820 65

    Air conditioner BKT EGO10

    (230V, 50-60Hz, 1050W) - side 783 28 110A9005348 213 1000 65

    Air conditioner BKT EGO12

    (230V, 50-60Hz, 1250W) - side 1003 38 110A9007406 237 1250 65

    Air conditioner BKT EGO16

    (230V, 50-60Hz, 1600W) - side 999 40 110A9009406 237 1600 65

    Air conditioner BKT EGO20

    (230V, 50-60Hz, 2000W) - side 1003 52 110A9011406 237 2000 70

    Air conditioner BKT EGO30

    (230V, 50-60Hz, 2900W) - side 1265 80 110A9013535 335 2900 70

    Air conditioner BKT EGO40

    (230V, 50-60Hz, 3850W) - side 1265 82 110A9015535 335 3850 70

    Air conditioner BKT EGO40A

    (400V, 3~50Hz, 3850W) - side 1265 85 110A9016535 335 3850 70

    Air conditioner BKT EGO60

    (400V, 3~50Hz, 5800W) - side 2000 150 110A9017600 380 5800 72

    Air conditioner BKT EGO80

    (400V, 3~50Hz, 7600W) - side 2000 160 110A9019800 380 7600 75

    Air conditioner BKT EGOA0

    (400V, 3~50Hz, 9400W) - side 2000 180 110A9021800 380 10000 77

    Air conditioner BKT EGOA5

    (400V, 3~50Hz, 14800W) - side 2000 240 110A9023800 550 14800 67

    11

  • Environmental Condition Monitoring System

    The controller is designed to monitor environmental parameters (temperature, humidity, etc.) in a telecommunications cabinet or in small rooms. Its purpose is to warn users

    about a potential hazard and report any failures. 28 analogue sensors, 36 sensors with a potential-contact output and two signalling devices can be connected to the

    controller.

    Device characteristics and technical parameters

    Hardware

    Analogous

    inputs

    4 inputs (RJ12 sockets) for specific analogous sensors.

    Any combination of 4 sensors can be connected to the device.

    Some sensors can be connected in stacks.

    The type of a sensor is detected automatically.

    Potential-free

    inputs

    4 inputs (removable terminal strip) for any sensors with output

    and potential-free contacts.

    Outputs 2 voltage outputs (removable terminal strip) 12V/250mA

    CAN connector Connector for up to 8 extension modules for additional EA321 analogous

    inputs and additional EE322 potential-free inputs

    Other connectors 10/100Mbps Ethernet port (RJ45 socket)

    USB 2.0 port (Mini-B socket)

    Other Optional card of a GSM module

    Power supply External plug adapter 12V/1A, power consumption ≤ 10W

    Dimensions 180x80x33 (width x depth x height)

    Operating

    conditions

    Temperature: 0°C - 60°C

    Humidity: 0% - 90% RH (no condensation)

    Weight 400g

    Software

    Operating system Linux

    Configuration Through a web interface

    Supported protocols HTTP, HTTPS, PING, DHCP, RADIUS, SYSLOG,

    FTP, SNTP, SMTP, SNMP (v1,v2,v3)

    Alarm notifications Email, SNMP trap, SMS (optionally)

    Functionality See tables below

    Basic functionality

    ź Automatic sensor presence and type detection

    ź Adjustable logic functions

    ź Monitoring of conditions of other devices in a network through PING, SNMP Get protocols

    ź Access to a limited history of measurement values

    ź Loading an object map for the device

    ź 4 alarm thresholds for the sensor

    ź SMS, email, SNMP Trap notofications

    ź Support for a USB camera (e.g. Logitech C210) for remote monitoring of IT infrasturcture

    ź Creating users of different access rights

    ź Visualisation of device status from external software, e.g. SM4DC

    Index: 122EC003350

    Analogue sensors

    Type Description Index

    122ES003500

    ES350 – Temperature sensor

    Measurement range: -10°C - +100°C

    Dimensions: 60x18x18

    Maximum length of a connection cable: 100m

    122ES003510

    ES351 – Humidity sensor

    Measurement range: 10% - 95% RH

    Dimensions: 60x18x18

    Maximum length of a connection cable: 50m

    122ES003520

    ES352 – Voltage sensor 230V AC

    Measurement range: 90VAC - 250VAC

    Dimensions: 63x66x30

    Maximum length of a connection cable: 100m

    122ES003530

    ES353 – Door sensor (reed relay + magnet)

    Possible stack connection of up to 10 sensors

    Dimensions: 60x18x18

    Maximum length of a connection cable: 150m

    EC335 4DC Environmental Condition Controller

    12

  • Environmental Condition Monitoring System

    Analogue sensors

    Type

    122ES003540

    ES354 – Vibration sensor

    Possible stack connection of up to 10 sensors

    Dimensions: 60x18x18

    Maximum length of a connection cable: 150m

    Description Index

    122ES003560

    ES356 – Optical smoke sensor

    Possible stack connection of up to 10 sensors

    Dimensions: 100x45

    Maximum length of a connection cable: 150m

    122ES003570

    ES357 – Passive infrared sensor

    Movement detection range: 100° x 12m

    Dimensions: 105x57x40

    Maximum length of a connection cable: 50m

    122ES003580

    ES358 – External temperature sensor

    Measurement range: -40°C - +100°C

    Dimensions: 7x30 + 15m cable

    Maximum length of a connection cable: 100m

    122ES003590

    ES359 – Flood sensor

    Detection delay: 1s

    Dimensions: 60x18x18

    Maximum length of a connection cable: 100m

    122ES003600

    ES360 – Flood sensor for a water detection cable

    For connection of an ES361 water detection cable

    Dimensions: 60x18x18

    Maximum length of a connection cable: 100m

    122ES003610

    ES361 - Sensor detecting water and other conductive liquids

    An ES360 sensor is required for connection

    Dimensions: 60x18x18

    Available lengths: 6m, 10m, 25m, 50m

    122ES003620

    ES362 - 4-20mA sensor

    Any sensors with 4-20mA output can be connected to the controller

    Galvanic insulation 1kV between the input and output

    Dimensions: 60x18x18

    122ES003630

    ES363 - 60V DC voltage sensor

    Galvanic insulation 1kV between the input and output.

    Measurement range: 0VDC - 60VDC

    Dimensions: 60x18x18

    Extension modules and accessories

    Type

    122EA003170

    EA317 - GSM modem for EC300 4DC

    Dimensions: 60x50x15

    A modem for SMS communication operating

    in GSM 850/900/1800/1900 MHz networks.

    Description Index

    122EE003210

    EE321 – Extension module with additional 8 analogous inputs

    The module is connected to a CAN controller connector.

    The controller supports up to 28 analogous sensors.

    The module has no 19” brackets.

    Dimensions: 110x68x40

    122EE003220

    EE322 – Extension module with additional 32 potential-free inputs

    The module is connected to a CAN controller connector.

    The controller supports up to 32 additional potential-free inputs.

    19” brackets included.

    Dimensions: 215x40x40

    122EA003110

    EA311 - 1U bracket for a 19'' cabinet for EC335 4DC

    Dimensions: 482x44x80

    122EA003150

    EA315 - Light indicator

    Power voltage 12V, 80mA

    Dimensions: ɸ73x45

    Flashing frequency: 1Hz

    EC335 4DC Environmental Condition Controller

    13

  • External street distribution cabinets

    External street distribution cabinets are used for ICT networks and form an intermediate point between the operator and the subscriber. Such cabinets are intended for

    inclusion of passive copper and fibre optic elements which do not require specific ambient conditions as is the case with external distribution cabinets.

    Standard cabinets are equipped with the following elements:

    ź Assembly panel

    ź 19” sections (only model 11150010.1) – width of 580 mm makes it possible to install 19” sections

    ź Retractable integrated base

    ź Single - point lock with a cylinder

    ź Removable doors facilitating assembly

    All cabinet made of steel sheet metal with RAL7035 powder coating.

    Available models:

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    BKT external street distribution cabinet 1250 11150001.1480 225

    Equipment

    Assembly panel

    BKT external street distribution cabinet 1250 11150012.1580 240 Assembly panel

    BKT external street distribution cabinet 1250 11150010.1580 240 19" section

    BKT external street distribution cabinet 1250 11150020.1780 240 Assembly panel

    BKT external street distribution cabinet 1250 11150030.1930 240 Assembly panel

    14

    BKT-ZSD

  • IP protection

    First IP number

    Second IP number

    Classification of degrees of protection provided by enclosures (IP code)

    Classification of degrees of protection of electrical equipment provided by enclosures according to the standards PN-92/E-08106.

    Identical standards:

    EN 60529:1991, IEC 529:1989. Also : VDE 0470, DIN 40050, BS 5490:1977

    Example of IP code: IP54

    First IP number: 5 = protection from unauthorized access with the use of wire , dust protection

    Second IP number: 4 = protected against water sprayed from all directions

    Protection of device against solid

    objectsProtection from people's access

    0 no protection no protection

    1 diameter > 50 mm with a hand

    2 diameter > 12,5 mm with a finger

    3 diameter > 2,5 mm with a tool

    4 diameter > 1,0 mm with a wire

    5 limited dust protection with a wire

    6 dust protection with a wire

    Protection of device against liquids

    0 no protection

    1 protection against vertically falling drops of water

    2 protection against falling drops of water up to 15° from the vertical

    3 protected against direct sprays of water

    4 protection against water sprayed from all directions

    5 protected against low pressure jets of water

    6 protected against moderate pressure jets of water

    7 protected against temporary flooding

    8 protected against the effect of immersion

    9K protected against jets of water under pressure 80-100 [bar] up to +80°C according to DIN 400050

    15

  • Outdoor FTTx Cabinets

    The cabinets are applied in the construction of fibre optic networks and are used as points for the execution of subscriber utility connections.

    Available models:

    NameWidth

    (mm)

    Index

    RAL7035

    Depth

    (mm)

    Height

    (mm)

    Outdoor distribution cabinet BKT for FTTx 48xSC Simplex 1280 110A6111317 214

    Outdoor distribution cabinet BKT for FTTx for 216 fibres 1280 110A6112317 214

    Ground-standing optical distribution box 450/920/355

    IP55 for 144 subscriber lines (aluminium) 920 11194930.1450 355

    Construction features:

    ź Cabinet made of an aluminium sheet;

    ź Plinth made of stainless steel (for FTTx cabinets);

    ź Powder painted in RAL7035;

    ź All the elements of the cabinet are earthed;

    ź Lock with a cylinder with key.

    16

  • 17

  • System of weighing trucks on access road to cities

    18

    System of weighing trucks on access road to cities

  • Bydgoszcz Industrial and Technological Park – power supply distribution

    System of weighing trucks on access road to cities

    19

  • Dolnośląska Broadband Network – Internet Development in Poland

    Bydgoszcz Główna Railway Station – Information totem

    20

  • Provincial Broadband Network – Internet for Mazovia – Internet development in Poland

    System of weighing trucks on access road to cities

    21

  • Bydgoszcz Główna Railway Station – Information totem

    22

  • Notes

    23


Recommended