Ideal solution for industrial, commercial and other high bayapplications
DESCRIPTIONThe T1-RHBLED series is the latest addition to our line of LED high bay fixtures. With its modern and sleek design, these LED high bays feature a thin, circularprofile that will improve the aesthetics of any industrial, commercial or high ceiling retail facility. The T1-RHBLED series is offered in multiple lumen packages andcolor temperatures with multiple reflector and mounting options making these LED high bays the perfect solution for any high bay application.
SPECIF IC ATION FEATURES
MountingThe T1-RHBLED series can be suspended from the ceiling with hook or loop AYC chain andsurface mounted with a bracket.ConstructionHigh grade aluminum die cast with tempered glass lens or optional polycarbonate lensApplicationsIdeal solution for warehouses, retail, aisleway, etc.CertificationDLC Premium and ETL listed. All components have UL or ETL certification. Protection Grade IP65Warranty7-year Limited Warranty. See warranty documentation for more information.
Input Voltage 120V-277V, 347-480VInput Frequency 50/60 HzRated Wattage See Performance DataDelivered Lumens See Performance DataEfficacy >130 LPWCRI > 80Available CCT 4000K, 5000KColor Consistency 5-step MacAdam EllipseRated Life > 50,000 hoursAmbient Temp -20°C to 55°CPower Factor > 0.92THD < 20%Dimming 0-10V
L E D U F O
H i g h B a y
U F OT1-RHBLED
SERIES T1-RHBLED
RATED WATTAGE
/A/ 100
100 - 100W 150 - 150W 200 - 200W 230 - 230W
COLOR TEMP
- 40
40 - 4000K 50 - 5000K
VOLTAGE
- HV
[Blank] - 120-277V HV - 347-480V
DIMMING
[Blank] - 0-10V
CONTROLS
- OS
OS - On/off PIR High bay motion sensor DL - Daylight harvesting sensor
ACCESSORIES
- SM
[Blank] - Hook/Loop SM - Surface mount bracket
ORDERING OPTIONS [Example shown: T1—RHBLED/A/100-40-HV -SM-OS]
T1-RHBLED/A/100 T1-RHBLED/A/150 T1-RHBLED/A/200 T1-RHBLED/A/230
Prepared by: ____________________________
Date: _________________________________
Job Name: Catalog Number: Type:
Distributor:
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 1
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/100 - 11” x 11” x 5.6”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/100-40 100W 138 13800
T1-RHBLED/A/100-50 100W 142 14200
Max Cd: 4997.61 00 450 H 67.50 H 900 H 112.50 H
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 3,944.3 28.4 28.4
0-40 6,523.6 47.0 47.0
0-60 11,577.6 83.4 83.4
60-90 2,299.8 16.6 16.6
70-100 708.6 5.1 5.1
90-120 0.2 0 0
0-90 13,877.4 100 100
90-180 1.3 0 0
0-180 13,878.7 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 473.6 3.4
10-20 1,368.4 9.9
20-30 2,102.4 15.1
30-40 2,579.3 18.6
40-50 2,710.5 19.5
50-60 2,343.5 16.9
60-70 1,591.2 11.5
70-80 644.6 4.6
80-90 64.0 0.5
Zone Lumens %Total
90-100 0.0 0
100-110 0.1 0
110-120 0.2 0
120-130 0.2 0
130-140 0.2 0
140-150 0.2 0
150-160 0.2 0
160-170 0.1 0
170-180 0.0 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 13,670.6 152.1 152.1
Beam (50%): 77.6 10,764.5 112.5 112.4
Total: 100 13,874.8
U F O T1-RHBLED/A/100L E D U F O
H i g h B a y
0
833
1,667
2,500
3,333
4,167
5,000100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 2
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/100-HV - 11” x 11” x 5.6”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/100-40-HV 100W 138 13800
T1-RHBLED/A/100-50-HV 100W 142 14200
Max Cd: 4997.61 00 450 H 67.50 H 900 H 112.50 H
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 3,944.3 28.4 28.4
0-40 6,523.6 47.0 47.0
0-60 11,577.6 83.4 83.4
60-90 2,299.8 16.6 16.6
70-100 708.6 5.1 5.1
90-120 0.2 0 0
0-90 13,877.4 100 100
90-180 1.3 0 0
0-180 13,878.7 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 473.6 3.4
10-20 1,368.4 9.9
20-30 2,102.4 15.1
30-40 2,579.3 18.6
40-50 2,710.5 19.5
50-60 2,343.5 16.9
60-70 1,591.2 11.5
70-80 644.6 4.6
80-90 64.0 0.5
Zone Lumens %Total
90-100 0.0 0
100-110 0.1 0
110-120 0.2 0
120-130 0.2 0
130-140 0.2 0
140-150 0.2 0
150-160 0.2 0
160-170 0.1 0
170-180 0.0 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 13,670.6 152.1 152.1
Beam (50%): 77.6 10,764.5 112.5 112.4
Total: 100 13,874.8
U F O T1-RHBLED/A/100-HVL E D U F O
H i g h B a y
0
833
1,667
2,500
3,333
4,167
5,000100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 3
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/150 - 13.4” x 13.4” x 5.9”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/150-40 150W 138 20700
T1-RHBLED/A/150-50 150W 142 21300
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 5,788.6 27.9 27.9
0-40 9,574.6 46.1 46.1
0-60 17,133.0 82.5 82.5
60-90 3,626.0 17.5 17.5
70-100 1,175.7 5.7 5.7
90-120 0.5 0 0
0-90 20,758.9 100 100
90-180 1.9 0 0
0-180 20,760.9 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 695.5 3.3
10-20 2,007.9 9.7
20-30 3,085.3 14.9
30-40 3,786.0 18.2
40-50 3,991.1 19.2
50-60 3,567.3 17.2
60-70 2,450.4 11.8
70-80 1,049.7 5.1
80-90 125.8 0.6
Zone Lumens %Total
90-100 0.2 0
100-110 0.1 0
110-120 0.2 0
120-130 0.3 0
130-140 0.3 0
140-150 0.3 0
150-160 0.3 0
160-170 0.2 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 20,452.7 153.4 153.9
Beam (50%): 78.6 16,319.0 114.4 115.4
Total: 100 20,754.8
00 H 22.50 H 450 H 67.50 H 900 H
U F O T1-RHBLED/A/150L E D U F O
H i g h B a y
0
1,233
2,467
3,700
4,933
6,167
7,400100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 4
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/150-HV - 13.4” x 13.4” x 5.9”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/150-40-HV 150W 138 20700
T1-RHBLED/A/150-50-HV 150W 142 21300
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 5,788.6 27.9 27.9
0-40 9,574.6 46.1 46.1
0-60 17,133.0 82.5 82.5
60-90 3,626.0 17.5 17.5
70-100 1,175.7 5.7 5.7
90-120 0.5 0 0
0-90 20,758.9 100 100
90-180 1.9 0 0
0-180 20,760.9 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 695.5 3.3
10-20 2,007.9 9.7
20-30 3,085.3 14.9
30-40 3,786.0 18.2
40-50 3,991.1 19.2
50-60 3,567.3 17.2
60-70 2,450.4 11.8
70-80 1,049.7 5.1
80-90 125.8 0.6
Zone Lumens %Total
90-100 0.2 0
100-110 0.1 0
110-120 0.2 0
120-130 0.3 0
130-140 0.3 0
140-150 0.3 0
150-160 0.3 0
160-170 0.2 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 20,452.7 153.4 153.9
Beam (50%): 78.6 16,319.0 114.4 115.4
Total: 100 20,754.8
00 H 22.50 H 450 H 67.50 H 900 H
U F O T1-RHBLED/A/150-HVL E D U F O
H i g h B a y
0
1,233
2,467
3,700
4,933
6,167
7,400100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 5
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/200 - 15.75” x 15.75” x 5.7”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/200-40 200W 141 27446
T1-RHBLED/A/200-50 200W 140 28000
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 7,463.6 27.2 27.2
0-40 12,355.7 45 45
0-60 22,220.0 81 81
60-90 5,220.7 19 19
70-100 1,786.8 6.5 6.5
90-120 1.0 0 0
0-90 27,440.7 100 100
90-180 2.7 0 0
0-180 27,443.3 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 896.4 3.3
10-20 2,587.7 9.4
20-30 3,979.5 14.5
30-40 4,892.1 17.8
40-50 5,167.7 18.8
50-60 4,696.6 17.1
60-70 3,434.4 12.5
70-80 1,575.3 5.7
80-90 211.0 0.8
Zone Lumens %Total
90-100 0.5 0
100-110 0.2 0
110-120 0.3 0
120-130 0.4 0
130-140 0.4 0
140-150 0.4 0
150-160 0.3 0
160-170 0.2 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 27,048.5 155.9 155.9
Beam (50%): 78.3 21,493.6 116.5 116.5
Total: 100 27,435.2
00 H 22.50 H 450 H 67.50 H 900 H
U F O T1-RHBLED/A/200L E D U F O
H i g h B a y
0
1,583
3,167
4,750
6,333
7,917
9,500100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 6
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/200-HV - 15.75” x 15.75” x 5.7”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/200-40-HV 200W 141 27446
T1-RHBLED/A/200-50-HV 200W 140 28000
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 7,463.6 27.2 27.2
0-40 12,355.7 45 45
0-60 22,220.0 81 81
60-90 5,220.7 19 19
70-100 1,786.8 6.5 6.5
90-120 1.0 0 0
0-90 27,440.7 100 100
90-180 2.7 0 0
0-180 27,443.3 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 896.4 3.3
10-20 2,587.7 9.4
20-30 3,979.5 14.5
30-40 4,892.1 17.8
40-50 5,167.7 18.8
50-60 4,696.6 17.1
60-70 3,434.4 12.5
70-80 1,575.3 5.7
80-90 211.0 0.8
Zone Lumens %Total
90-100 0.5 0
100-110 0.2 0
110-120 0.3 0
120-130 0.4 0
130-140 0.4 0
140-150 0.4 0
150-160 0.3 0
160-170 0.2 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.5 27,048.5 155.9 155.9
Beam (50%): 78.3 21,493.6 116.5 116.5
Total: 100 27,435.2
00 H 22.50 H 450 H 67.50 H 900 H
U F O T1-RHBLED/A/200-HVL E D U F O
H i g h B a y
0
1,583
3,167
4,750
6,333
7,917
9,500100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 7
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/230 - 15.75” x 15.75” x 5.7”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/230-40 230W 131 30150
T1-RHBLED/A/230-50 230W 134 30820
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 8,386.5 27.8 27.8
0-40 13,857.2 45.9 45.9
0-60 24,785.2 82.1 82.1
60-90 5,408.8 17.9 17.9
70-100 1,762.7 5.8 5.8
90-120 0.7 0 0
0-90 30,194.0 100 100
90-180 2.6 0 0
0-180 30,196.6 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 1,009.0 3.3
10-20 2,910.4 9.6
20-30 4,467.1 14.8
30-40 5,470.8 18.1
40-50 5,746.9 19.0
50-60 5,181.2 17.2
60-70 3,646.2 12.1
70-80 1,577.7 5.2
80-90 184.9 0.6
Zone Lumens %Total
90-100 0.2 0
100-110 0.2 0
110-120 0.3 0
120-130 0.4 0
130-140 0.4 0
140-150 0.4 0
150-160 0.4 0
160-170 0.3 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.6 29,764.3 154.0 154.2
Beam (50%): 78.4 23,664.4 115.2 115.3
Total: 100 30,187.9
Max Cd: 10647.17 00 450 H 67.50 H 900 H 292.50 H
U F O T1-RHBLED/A/230L E D U F O
H i g h B a y
0
1,833
3,667
5,500
7,333
9,167
11,000100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 8
T-1 Lighting, Inc., 9929 Pioneer Boulevard, Santa Fe Springs, CA 90670 626-234-2328
www.t1- l ighting.com sales@t1- l ight ing.com
T1-RHBLED/A/230-HV - 15.75” x 15.75” x 5.7”
Catalog number Rated Wattage Efficacy Delivered Lumens
T1-RHBLED/A/230-40-HV 230W 131 30150
T1-RHBLED/A/230-50-HV 230W 134 30820
ZONAL LUMENS SUMMARY
Zone Lumens % Lamp % Luminaire
0-30 8,386.5 27.8 27.8
0-40 13,857.2 45.9 45.9
0-60 24,785.2 82.1 82.1
60-90 5,408.8 17.9 17.9
70-100 1,762.7 5.8 5.8
90-120 0.7 0 0
0-90 30,194.0 100 100
90-180 2.6 0 0
0-180 30,196.6 100 100
LUMENS PER ZONE
Zone Lumens %Total
0-10 1,009.0 3.3
10-20 2,910.4 9.6
20-30 4,467.1 14.8
30-40 5,470.8 18.1
40-50 5,746.9 19.0
50-60 5,181.2 17.2
60-70 3,646.2 12.1
70-80 1,577.7 5.2
80-90 184.9 0.6
Zone Lumens %Total
90-100 0.2 0
100-110 0.2 0
110-120 0.3 0
120-130 0.4 0
130-140 0.4 0
140-150 0.4 0
150-160 0.4 0
160-170 0.3 0
170-180 0.1 0
FLOOD SUMMARY
Efficiency % Lumens Horiz. Spread Vert. Spread
Field (10%): 98.6 29,764.3 154.0 154.2
Beam (50%): 78.4 23,664.4 115.2 115.3
Total: 100 30,187.9
Max Cd: 10647.17 00 450 H 67.50 H 900 H 292.50 H
U F O T1-RHBLED/A/230-HVL E D U F O
H i g h B a y
0
1,833
3,667
5,500
7,333
9,167
11,000100 200 300 400
900
800
700
600
500
T1-RHBLED.qxp_Layout 1 9/11/18 4:01 PM Page 9