INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 1/40A2745301C
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 2/40
RWS1500BINDEX
PAGE1. Evaluation Method
11. 測定回路 Circuit used for determination測定回路1 Circuit 1 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4
静特性 Steady state data通電ドリフト特性 Warm up voltage drift characteristics出力保持時間特性 Hold up time characteristics出力立ち上がり特性 Output rise characteristics出力立ち下がり特性 Output fall characteristics過電流保護特性 Over current protection (OCP) characteristics過電圧保護特性 Over voltage protection (OVP) characteristics入力電圧瞬停特性 Response to brown out characteristics入力電流波形 Input current waveform
測定回路2 Circuit 2 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4過渡応答(負荷急変)特性 Dynamic load response characteristics
測定回路3 Circuit 3 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5入力サージ電流(突入電流)波形 Inrush current waveform
測定回路4 Circuit 4 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5リーク電流特性 Leakage current characteristics
測定回路5 Circuit 5 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5出力リップル、ノイズ波形 Output ripple and noise waveform
測定回路6 Circuit 6 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control測定回路7 Circuit 7 used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6
無負荷時入力電力、電流 No load input power and currentスタンバイ立ち上がり、立ち下がり特性 Standby rise, fall characteristicsON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control測定構成 Configuration used for determination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7
EMI特性 ElectroMagnetic Interference characteristics(a) 雑音端子電圧(帰還ノイズ) Conducted Emission(b) 雑音電界強度(放射ノイズ) Radiated Emission
12. 使用測定機器 List of equipment used ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8
2. Characteristics RWS1500B
21. 静特性 Steady state data (1) 入力・負荷・温度変動/出力起動・遮断電圧
Regulation line and load, Temperature drift / Start up voltage and Drop out voltage ・・ 9(2) リップルノイズ電圧対入力電圧 Ripple noise voltage vs. Input voltage ・・・・・・・・・・・・・・ 10(3) 効率・力率対出力電流 Efficiency and Power factor vs. Output current ・・・・・・・・・・・・・ 11(4) 入力電力対出力電流 Input power vs. Output current ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 12(5) 入力電流対出力電流 Input current vs. Output current ・・・・・・・・・・・・・・・・・・・・・・・・・・・ 13
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 3/40
RWS1500B
PAGE22. 通電ドリフト特性 Warm up voltage drift characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1423. 出力保持時間特性 Hold up time characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1424. 出力立ち上がり特性 Output rise characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1525. 出力立ち下がり特性 Output fall characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1626. ON/OFFコントロール時出力立ち上がり、立下がり特性 (*)
Output rise, fall characteristics with ON/OFF Control (*) ・・・・・・・・・・・・・・・・・・・・・・・・・・ 1727. 過電流保護特性 Over current protection (OCP) characteristics ・・・・・・・・・・・・・・・・・・・・・・・ 1828. 過電圧保護特性 Over voltage protection (OVP) characteristics ・・・・・・・・・・・・・・・・・・・・・・・ 1829. 過渡応答(負荷急変)特性 Dynamic load response characteristics ・・・・・・・・・・・・・・・・・・・・・ 19210. 入力電圧瞬停特性 Response to brown out characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 20211. 入力サージ電流(突入電流)波形 Inrush current waveform ・・・・・・・・・・・・・・・・・・・・・・・・・・・ 21212. 高調波成分 Input current harmonics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 22213. 入力電流波形 Input current waveform ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 22214. リーク電流特性 Leakage current characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 23215. 出力リップル、ノイズ波形 Output ripple and noise waveform ・・・・・・・・・・・・・・・・・・・・・・・・・・ 24216. EMI特性 ElectroMagnetic Interference characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2528
RWS1500B/ME 217. リーク電流特性 Leakage current characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 29218. EMI特性 ElectroMagnetic Interference characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3033
RWS1500B/S 219. 無負荷時入力電力、電流 No load input power and current ・・・・・・・・・・・・・・・・・・・・・・・・・・・ 34220. スタンバイ立ち上がり、立ち下がり特性 Standby rise, fall characteristics ・・・・・・・・・・・・・・・・ 35221. ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 36222. EMI特性 ElectroMagnetic Interference characteristics ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3740
* 準標準品RWS1500B*/R, /RFO にて対応
For option model RWS1500B*/R, /RFO
使用記号 Terminology used定義 Definition
Vin ・・・・・ 入力電圧 Input voltageVout ・・・・・ 出力電圧 Output voltageIin ・・・・・ 入力電流 Input currentIout ・・・・・ 出力電流 Output currentTa ・・・・・ 周囲温度 Ambient temperaturef ・・・・・ 周波数 FrequencyVstb ・・・・・ スタンバイ電圧 Standby voltageIstb ・・・・・ スタンバイ電流 Standby current
※ 当社測定条件における結果であり、参考値としてお考え願います。
Test results are reference data based on our measurement condition.
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 4/40
RWS1500B1. Evaluation Method
11. 測定回路 Circuit used for determination
測定回路1 Circuit 1 used for determination• 静特性 Steady state data• 通電ドリフト特性 Warm up voltage drift characteristics• 出力保持時間特性 Hold up time characteristics• 出力立ち上がり特性 Output rise characteristics• 出力立ち下がり特性 Output fall characteristics• 過電流保護特性 Over current protection (OCP) characteristics• 過電圧保護特性 Over voltage protection (OVP) characteristics• 入力電圧瞬停特性 Response to brown out characteristics• 入力電流波形 Input current waveform
測定回路2 Circuit 2 used for determination• 過渡応答(負荷急変)特性 Dynamic load response characteristics
P.S.AC Powersupply
Controlled temp. chamber
AC
AC
V
V
+V
V
Shunt res.
Digital power meter
SW1
Current probe
A W
V
Load
P.S.AC Powersupply
tr tf
100%95%
Output current waveformIout 50% <==> 100%
AC
AC
Load 1
Load 2
V
V
+V
V
Shunt res.
Dynamic dummyload
SW1
55%50%Min
A W
V
Digital power meter
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 5/40
RWS1500B
測定回路3 Circuit 3 used for determination• 入力サージ電流 (突入電流) 波形 Inrush current waveform
測定回路4 Circuit 4 used for determination• リーク電流特性 Leakage current characteristics
測定回路5 Circuit 5 used for determination• 出力リップル、ノイズ波形 Output ripple and noise waveform
A W
V
AC
AC
P.S.
V
V
+V
V
Shunt res.
Load
Digital power meter
Current probe
Slide Reg.
Dynamic dip
simulator
P.S.AC Power
supply
接地Earth
Leakagecurrentmeter
Isolationtrans
AC AC
AC AC
FG FG
AC
AC
V
V
+V
V
Shunt res.
Load
A W
V
Digital power meter
P.S.AC
Powersupply
AC
AC
+V
V
SW1
A W
V
Digital power meter
Load
R
R : 50ΩC1 : 0.1uF Film cap.C2 : 47uF Elect cap.C3 : 4700pF Ceramic cap.
Coaxial cable1.5m 50Ω
OscilloscopeBandwidth : 20MHz
150mm
+
C1 C2C3
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 6/40
RWS1500B
測定回路6 Circuit 6 used for determination• ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control
準標準品 RWS1500B*/R, /RFO にて対応
For option model RWS1500B*/R, /RFO
* PF信号端子は、RWS1500B*/RFOのみ対応
PF signal terminal is applied to only RWS1500B*/RFO
測定回路7 Circuit 7 used for determination・無負荷時入力電力、電流 No load input power and current・スタンバイ立ち上がり、立ち下がり特性 Standby rise, fall characteristics・ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control
準標準品 RWS1500B*/S にて対応
For option model RWS1500B*/S
P.S.AC Power
supply
AC
AC
V
V
+V
V
Shunt res.
Digital power meter
SW1
A W
V
Load
R +R PF +PF
SW212V
12V
P.S.AC Power
supply
AC
AC
V
+V
V
Shunt res.
Digital power meter
SW1A
VLoad1
R +R
W
+STBSTB
V
Load2SW2
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 7/40
RWS1500B
測定構成 Configuration used for determination• EMI特性 ElectroMagnetic Interference characteristics
(a) 雑音端子電圧(帰還ノイズ) Conducted Emission
(b) 雑音電界強度(放射ノイズ) Radiated Emission
アルミ板Aluminum plate
垂直基準大地面
(2m × 2m)Vertical groundreference plane
D=40cm擬似電源回路網AMN 50Ω/50uH
EMI Test receiverspectrum analyzer
供試機器(接地)D.U.T(Earthed)
D=80cm
H=80cm台Stand
入力電源AC Power supply
電源ケーブルPower cable
接地Earth
水平大地面Horizontal ground plane
供試機器(接地)D.U.T(Earthed) アルミ板
Aluminum plate
アンテナAntenna
EMI Test receiver spectrum analyzerpre amp.
水平大地面Horizontal ground plane
D=3m
H=80cm台Stand
入力電源AC Power supply
ターンテーブルTurn table
電源ケーブルPower cable
接地Earth
水平大地面Horizontal ground plane
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 8/40
RWS1500B12. 使用測定機器 List of equipment used
EQUIPMENT USED MANUFACTURER MODEL NO.
1 DIGITAL STORAGE OSCILLOSCOPE YOKOGAWA ELECT. DLM2054
2 DIGITAL MULTIMETER AGILENT 34970A
3 DIGITAL POWER METER YOKOGAWA ELECT. WT310HC
4 DIGITAL POWER METER HIOKI 3331 / 3332
5 CURRENT PROBE YOKOGAWA ELECT. 701928 / 701930
6 DYNAMIC DUMMY LOAD KIKUSI PLZ1004W / PLZ2004WB
7 DYNAMIC DUMMY LOAD TEXIO LSG1050
8 DUMMY LOAD PCN RHF250 SIRIES
9 SLIDE REGULATOR MATSUNAGA SD2650
10 ISOLATION TRANS MATSUNAGA 3WTC50K
11 CVCF KIKUSUI PCR4000L / PCR4000LA
12 CVCF KIKUSUI PCR4000LE / PCR6000LE
13 LEAKAGE CURRENT METER HIOKI 3156
14 DYNAMIC DIP SIMULATOR TAKAMISAWA PSA210
15 CONTROLLED TEMP. CHAMBER ESPEC PL1KP
16 ROHDE & SCHWARZ ESCI
17 PRE AMP. SONOMA 310N
18 AMN SCHWARZBECK NNLK8121
19 ANTENNA SCHWARZBECK CBL6111D
20 HARMONIC / FLICKER ANALYZER KIKUSUI KHA1000
21 SINGLEPHASE MASTER NF 4420
22 NF 4150
23 MULTI OUTLET UNIT KIKUSUI OT01KHA
EMI TEST RECEIVER / SPECTRUM ANALYZER
REFERENCE IMPEDANCE NETWORK 20A
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 9/40
RWS1500B2. Characteristics
21. 静特性 Steady state data(1) 入力・負荷・温度変動/出力起動・遮断電圧
Regulation line and load, Temperature drift / Start up voltage and Drop out voltage
12V 1. Regulation line and load Condition Ta : 25 °CIout \ Vin 90VAC 100VAC 200VAC 265VAC Line regulation
0% 12.024V 12.023V 12.024V 12.024V 1mV50% 11.988V 11.989V 11.989V 11.990V 2mV
100% 11.958V 11.958V 11.959V 11.959V 1mV66mV 65mV 65mV 65mV
0.550% 0.542% 0.542% 0.542%
2. Temperature drift Conditions Vin : 100 VACIout : 100 %
Ta 20°C +25°C +50°C Temperature stability Vout 11.993V 11.958V 11.948V 45mV 0.375%
3. Start up voltage and Drop out voltage Conditions Ta : 25 °CIout : 100 %
Start up voltage (Vin) 77VACDrop out voltage (Vin) 71VAC
24V 1. Regulation line and load Condition Ta : 25 °CIout \ Vin 90VAC 100VAC 200VAC 265VAC Line regulation
0% 23.967V 23.968V 23.969V 23.969V 2mV50% 23.945V 23.945V 23.945V 23.946V 1mV
100% 23.930V 23.930V 23.931V 23.931V 1mV37mV 38mV 38mV 38mV
0.154% 0.158% 0.158% 0.158%
2. Temperature drift Conditions Vin : 100 VACIout : 100 %
Ta 20°C +25°C +50°C Temperature stability Vout 23.916V 23.930V 23.946V 30mV 0.125%
3. Start up voltage and Drop out voltage Conditions Ta : 25 °CIout : 100 %
Start up voltage (Vin) 78VACDrop out voltage (Vin) 72VAC
48V 1. Regulation line and load Condition Ta : 25 °CIout \ Vin 90VAC 100VAC 200VAC 265VAC Line regulation
0% 47.997V 47.997V 47.997V 47.997V 0mV50% 47.978V 47.978V 47.978V 47.979V 1mV
100% 47.969V 47.969V 47.970V 47.970V 1mV28mV 28mV 27mV 27mV
0.058% 0.058% 0.056% 0.056%
2. Temperature drift Conditions Vin : 100 VACIout : 100 %
Ta 20°C +25°C +50°C Temperature stability Vout 47.930V 47.969V 47.986V 56mV 0.117%
3. Start up voltage and Drop out voltage Conditions Ta : 25 °CIout : 100 %
Start up voltage (Vin) 78VACDrop out voltage (Vin) 71VAC
0.008%0.017%0.008%
Load regulation
0.008%0.004%0.004%
Load regulation
0.000%0.002%0.002%
Load regulation
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 10/40
RWS1500B(2) リップルノイズ電圧対入力電圧 Ripple noise voltage vs. Input voltage
Ripple noise voltage vs. Input voltage Conditions Iout : 100 %Ta : 20 °C
25 °C50 °C
12V
24V
48V
0
20
40
60
80
100
120
140
50 100 150 200 250Ripp
le n
oise
vol
tage
(mV)
Input voltage (VAC)
0
20
40
60
80
100
120
140
50 100 150 200 250
Ripp
le n
oise
vol
tage
(mV)
Input voltage (VAC)
0
60
120
180
240
300
360
420
50 100 150 200 250
Ripp
le n
oise
vol
tage
(mV)
Input voltage (VAC)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 11/40
RWS1500B(3) 効率・力率対出力電流 Efficiency and Power factor vs. Output current
Efficiency and Power factor vs. Output current Conditions Vin : 90 VAC100 VAC200 VAC265 VAC
Ta : 25 ℃
12V
24V
48V
50
60
70
80
90
0 20 40 60 80 100
Effic
ienc
y (%
)
Output current (%)
0.6
0.7
0.8
0.9
1.0
0 20 40 60 80 100Po
wer
fact
or
Output current (%)
50
60
70
80
90
0 20 40 60 80 100
Effic
ienc
y (%
)
Output current (%)
0.6
0.7
0.8
0.9
1.0
0 20 40 60 80 100
Pow
er fa
ctor
Output current (%)
50
60
70
80
90
0 20 40 60 80 100
Effic
ienc
y (%
)
Output current (%)
0.6
0.7
0.8
0.9
1.0
0 20 40 60 80 100
Pow
er fa
ctor
Output current (%)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 12/40
RWS1500B(4) 入力電力対出力電流 Input power vs. Output current
* 準標準品 RWS1500B*/R, /RFO にて対応
For option model RWS1500B*/R, /RFO
Input power vs. Output current Conditions Vin : 90 VAC100 VAC200 VAC265 VAC
Ta : 25 ℃
12V
Iout : 0% Control OFF*90VAC 24.4W 2.8W
100VAC 24.3W 2.6W200VAC 24.1W 2.8W265VAC 23.3W 2.9W
24V
Iout : 0% Control OFF*90VAC 26.7W 2.7W
100VAC 26.6W 2.7W200VAC 26.4W 2.8W265VAC 25.6W 2.8W
48V
Iout : 0% Control OFF*90VAC 29.8W 3.0W
100VAC 29.6W 2.9W200VAC 29.2W 2.8W265VAC 28.4W 2.9W
Vin
Vin
Vin Input power
Input power
Input power
0
600
1200
1800
2400
0 20 40 60 80 100In
put p
ower
(W)
Output current (%)
0
600
1200
1800
2400
0 20 40 60 80 100
Inpu
t pow
er (W
)
Output current (%)
0
600
1200
1800
2400
0 20 40 60 80 100
Inpu
t pow
er (W
)
Output current (%)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 13/40
RWS1500B(5) 入力電流対出力電流 Input current vs. Output current
* 準標準品 RWS1500B*/R, /RFO にて対応
For option model RWS1500B*/R, /RFO
Input current vs. Output current Conditions Vin : 90 VAC100 VAC200 VAC265 VAC
Ta : 25 ℃
12V
Iout : 0% Control OFF*
90VAC 0.35A 0.12A100VAC 0.32A 0.13A200VAC 0.32A 0.25A265VAC 0.39A 0.33A
24V
Iout : 0% Control OFF*90VAC 0.38A 0.12A
100VAC 0.37A 0.13A200VAC 0.32A 0.25A265VAC 0.41A 0.33A
48V
Iout : 0% Control OFF*
90VAC 0.41A 0.12A100VAC 0.38A 0.13A200VAC 0.34A 0.25A265VAC 0.41A 0.32A
Vin
Vin
Vin
Input current
Input current
Input current
0.0
6.0
12.0
18.0
24.0
0 20 40 60 80 100In
put c
urre
nt (A
)
Output current (%)
0.0
6.0
12.0
18.0
24.0
0 20 40 60 80 100
Inpu
t cur
rent
(A)
Output current (%)
0.0
6.0
12.0
18.0
24.0
0 20 40 60 80 100
Inpu
t cur
rent
(A)
Output current (%)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 14/40
RWS1500B22. 通電ドリフト特性 23. 出力保持時間特性
Warm up voltage drift characteristics Hold up time characteristics
Conditions Vin : 100 VAC Conditions Vin : 100 VACIout : 100 % 200 VAC
Ta : 25 °C Ta : 25 °C12V
24V
48V
0.2
0.1
0.0
0.1
0.2
0 1 2 3 4 5 6 7 8
Out
put v
olta
ge d
rift (
%)
Time (hours)
10
100
1000
0 20 40 60 80 100H
old
up ti
me (
ms)
Output current (%)
0.2
0.1
0.0
0.1
0.2
0 1 2 3 4 5 6 7 8
Out
put v
olta
ge d
rift (
%)
Time (hours)
10
100
1000
0 20 40 60 80 100
Hol
d up
tim
e (m
s)
Output current (%)
0.2
0.1
0.0
0.1
0.2
0 1 2 3 4 5 6 7 8
Out
put v
olta
ge d
rift (
%)
Time (hours)
10
100
1000
0 20 40 60 80 100
Hol
d up
tim
e (m
s)
Output current (%)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 15/40
RWS1500B24. 出力立ち上がり特性 Output rise characteristics
Output rise characteristics Conditions Vin : 90 VAC (A)100 VAC (B)200 VAC (C)265 VAC (D)
Ta : 25 ℃
12VIout : 0% Iout : 100%
5V/DIV 200ms/DIV 5V/DIV 200ms/DIV
24VIout : 0% Iout : 100%
10V/DIV 200ms/DIV 10V/DIV 200ms/DIV
48VIout : 0% Iout : 100%
20V/DIV 200ms/DIV 20V/DIV 200ms/DIV
D C BA
D C BA
D C BA
D C BA
← Vin →
← 0V →
← Vout →
← Vin →
← 0V →
← Vout →
← Vin →
← 0V →
← Vout →
D C BA
D C BA
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 16/40
RWS1500B25. 出力立ち下がり特性 Output fall characteristics
Output fall characteristics Conditions Vin : 90 VAC (A)100 VAC (B)200 VAC (C)265 VAC (D)
Ta : 25 ℃
12VIout : 0% Iout : 100%
5V/DIV 1s/DIV 5V/DIV 20ms/DIV
24VIout : 0% Iout : 100%
10V/DIV 1s/DIV 10V/DIV 20ms/DIV
48VIout : 0% Iout : 100%
20V/DIV 1s/DIV 20V/DIV 20ms/DIV
ABCD
ABCD
ABCD
← Vin →
← 0V →
← Vout →
← Vin →
← 0V →
← Vout →
← Vin →
← 0V →
← Vout →
ABCD
ABCDABCD
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 17/40
RWS1500B26. ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control
準標準品 RWS1500B*/R, /RFO にて対応
For option model RWS1500B*/R, /RFO
* PF信号は、RWS1500B*/RFOのみ対応
PF signal is applied to only RWS1500B*/RFO
Conditions Vin : 100 VACIout : 100 %Ta : 25 °C
12V
5V/DIV 50ms/DIV 5V/DIV 5ms/DIV
24V
10V/DIV 50ms/DIV 10V/DIV 5ms/DIV
48V
20V/DIV 50ms/DIV 20V/DIV 5ms/DIV
← 0V →
← Vout →
←ON/OFF→Control
← PF →Signal
← 0V →
← Vout →
←ON/OFF→Control
← PF →Signal
← 0V →
← Vout →
←ON/OFF→Control
← PF →Signal
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 18/40
RWS1500B27. 過電流保護特性 28. 過電圧保護特性
Over current protection (OCP) characteristics Over voltage protection (OVP) characteristics
Conditions Vin : 100 VAC Conditions Vin : 100 VACTa : 20 ℃ Iout : 0 %
25 ℃ Ta : 25 ℃
50 ℃
12V
5V/DIV 1s/DIV
24V
10V/DIV 1s/DIV
48V
20V/DIV 1s/DIV
0
4
8
12
16
0 50 100 150 200
Out
put v
olta
ge (V
)
Output current (%)
0
16
32
48
64
0 50 100 150 200
Out
put v
olta
ge (V
)
Output current (%)
OVP Point
OVP Point
OVP Point
0V →
Vout →
0V →
Vout →
0V →
Vout →
0
8
16
24
32
0 50 100 150 200
Out
put v
olta
ge (V
)
Output current (%)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 19/40
RWS1500B29. 過渡応答(負荷急変)特性 Dynamic load response characteristics
Dynamic load response characteristics Conditions Vin : 100 VACIout : 50 % 100 %
(tr = tf = 75us)Ta : 25 ℃
12Vf = 100Hz f = 1kHz
500mV/DIV 2ms/DIV 500mV/DIV 200μs/DIV+1.32% 1.33% +1.36% 1.29%
24Vf = 100Hz f = 1kHz
500mV/DIV 2ms/DIV 500mV/DIV 200μs/DIV+0.44% 0.40% +0.35% 0.39%
48Vf = 100Hz f = 1kHz
500mV/DIV 2ms/DIV 500mV/DIV 200μs/DIV+0.35% 0.34% +0.37% 0.37%
←Iout:0%→
←Vout→
←Iout→
←Iout:0%→
←Vout→
←Iout→
←Iout:0%→
←Vout→
←Iout→
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 20/40
RWS1500B210. 入力電圧瞬停特性 Response to brown out characteristics
Response to brown out characteristics Conditions Iout : 100% Ta : 25 ℃
瞬停時間 Interruption timeA : 出力電圧が低下なし Output voltage does not drop.B : 出力電圧の低下が0Vまでいかない Output voltage drop down not reaching 0V.C : 出力電圧が0Vまで低下 Output voltage drops until 0V.
Vin : 100VAC Vin : 200VACA = 23ms, B = 37ms, C = 45ms A = 24ms, B = 39ms, C = 46ms
5V/DIV 100ms/DIV 5V/DIV 100ms/DIV
Vin : 100VAC Vin : 200VACA = 25ms, B = 38ms, C = 44ms A = 27ms, B = 39ms, C = 44ms
10V/DIV 100ms/DIV 10V/DIV 100ms/DIV
Vin : 100VAC Vin : 200VACA = 26ms, B = 40ms, C = 44ms A = 27ms, B = 41ms, C = 45ms
20V/DIV 100ms/DIV 20V/DIV 100ms/DIV
12V
24V
48V
B A C
←0V→
←Vin→
←Vout→
B A C
B A C B A C
←0V→
←Vin→
←Vout→
←0V→
←Vin→
←Vout→
B A C B A C
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 21/40
RWS1500B211. 入力サージ電流(突入電流)波形 Inrush current waveform
12VConditions Vin : 100 VAC
Iout : 100%Ta : 25 ℃
20A/DIV 100ms/DIV 20A/DIV 100ms/DIV
Conditions Vin : 200 VACIout : 100%Ta : 25 ℃
20A/DIV 100ms/DIV 20A/DIV 100ms/DIV
Switch on phase angle of input AC voltageφ = 0°
Switch on phase angle of input AC voltageφ = 90°
Switch on phase angle of input AC voltageφ = 0°
Switch on phase angle of input AC voltageφ = 90°
← Iin →
← Vin →
← Iin →
← Vin →
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 22/40
RWS1500B212. 高調波成分 Input current harmonics
213. 入力電流波形 Input current waveform
Input current harmonics Conditions Iout : 100% Ta : 25 ℃
12VVin : 100 VAC
Vin : 230 VAC
0.001
0.010
0.100
1.000
10.000
100.000
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Har
mon
ic c
urre
nt (A
)
Harmonic order
IEC6100032 Limit (class A)
0.001
0.010
0.100
1.000
10.000
100.000
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Har
mon
ic c
urre
nt (A
)
Harmonic order
JIS C6100032 Limit (class A)
Input current waveform Conditions Iout : 100% Ta : 25 ℃
12VVin : 100 VAC Vin : 230 VAC
20A/DIV 5ms/DIV 20A/DIV 5ms/DIV
←Vin→
←Iin→
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 23/40
RWS1500B214. リーク電流特性 Leakage current characteristics
Leakage current characteristics Conditions Iout : 0 %100 %
Ta : 25 °CEquipment used : 3156 (HIOKI)
12V
f : 50 Hz
f : 60 Hz
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
80 120 160 200 240 280
Leak
age
curre
nt (m
A)
Input voltage (VAC)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
80 120 160 200 240 280
Leak
age
curre
nt (m
A)
Input voltage (VAC)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 24/40
RWS1500B215. 出力リップル、ノイズ波形 Output ripple and noise waveform
Output ripple and noise waveform Conditions Vin : 100 VACIout : 100 %Ta : 25 ℃
20mV/DIV 2μs/DIV
20mV/DIV 2μs/DIV
20mV/DIV 2μs/DIV
12V
24V
48V
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 25/40
RWS1500B216. EMI特性 ElectroMagnetic Interference characteristics
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
ElectroMagnetic Interference characteristics Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
12VPhase : N
Point A(165kHz)
Ref. Limit MeasureData (dB) (dB)
QP 65.2 47.0
AV 55.2 46.9
Point B(14.0MHz)
Ref. Limit MeasureData (dB) (dB)
QP 60.0 43.8
AV 50.0 41.6
Phase : LPoint C
(163kHz)Ref. Limit Measure
Data (dB) (dB)
QP 65.3 51.7
AV 55.3 49.7
Point D(14.0MHz) Phase : L
Ref. Limit MeasureData (dB) (dB)
QP 60.0 44.9
AV 50.0 42.7
A
C VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
B
D
VCCI Class BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 26/40
RWS1500B
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
24VPhase : N
Point A(3.9MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 36.9
AV 46.0 35.8
Point B(13.7MHz)
Ref. Limit MeasureData (dB) (dB)
QP 60.0 45.3
AV 50.0 40.4
Phase : LPoint C
(3.9MHz)Ref. Limit Measure
Data (dB) (dB)
QP 56.0 41.9
AV 46.0 40.5
Point D(13.5MHz) Phase : L
Ref. Limit MeasureData (dB) (dB)
QP 60.0 45.9
AV 50.0 40.7
VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
A
C
B VCCI Class BQP Limit
D
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 27/40
RWS1500B
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
48VPhase : N
Point A(168kHz)
Ref. Limit MeasureData (dB) (dB)
QP 65.1 46.0
AV 55.1 44.0
Point B(4.5MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 42.0
AV 46.0 38.9
Phase : LPoint C
(167kHz)Ref. Limit Measure
Data (dB) (dB)
QP 65.1 41.9
AV 55.1 36.9
Point D(4.6MHz) Phase : L
Ref. Limit MeasureData (dB) (dB)
QP 56.0 43.8
AV 46.0 40.0
VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
A
C
B
D
VCCI Class BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 28/40
RWS1500B
EN55011B,EN55032Bの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B are same as its VCCI class B.表示はピーク値
Indication is peak values.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音電界強度
Radiated Emission
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
12V
24V
48V
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 29/40
RWS1500B217. リーク電流特性 Leakage current characteristics
MODEL : RWS1500B/MELeakage current characteristics Conditions Iout : 0 %
100 %Ta : 25 °C
Equipment used : 3156 (HIOKI)
12V
f : 50 Hz
f : 60 Hz
0.0
0.1
0.2
0.3
80 120 160 200 240 280
Leak
age
curre
nt (m
A)
Input voltage (VAC)
0.0
0.1
0.2
0.3
80 120 160 200 240 280
Leak
age
curre
nt (m
A)
Input voltage (VAC)
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 30/40
RWS1500B218. EMI特性 ElectroMagnetic Interference characteristics
MODEL : RWS1500B/ME
EN55011A,EN55032A,FCCAの限界値はVCCI class Aの限界値と同じ
Limit of EN55011A,EN55032A,FCCA are same as its VCCI class A.
ElectroMagnetic Interference characteristics Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
12VPhase : N
Point A(166kHz)
Ref. Limit MeasureData (dB) (dB)
QP 79.0 49.4
AV 66.0 48.2
Point B(14.3MHz)
Ref. Limit MeasureData (dB) (dB)
QP 73.0 52.8
AV 60.0 51.4
Phase : LPoint C
(164kHz)Ref. Limit Measure
Data (dB) (dB)
QP 79.0 47.9
AV 66.0 47.5
Point D(14.3MHz) Phase : L
Ref. Limit MeasureData (dB) (dB)
QP 73.0 52.8
AV 60.0 51.4
A
C
VCCI Class AQP Limit
VCCI Class AAV Limit
VCCI Class AAV Limit
B
D
VCCI Class AQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 31/40
RWS1500B
MODEL : RWS1500B/ME
EN55011A,EN55032A,FCCAの限界値はVCCI class Aの限界値と同じ
Limit of EN55011A,EN55032A,FCCA are same as its VCCI class A.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
24VPhase : N
Point A(164kHz)
Ref. Limit MeasureData (dB) (dB)
QP 79.0 54.2
AV 66.0 54.2
Phase : LPoint B
(164kHz)Ref. Limit Measure
Data (dB) (dB)
QP 79.0 55.1
AV 66.0 55.1
Phase : L
VCCI Class AQP Limit
VCCI Class AAV Limit
VCCI Class AAV Limit
A
B
VCCI Class AQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 32/40
RWS1500B
MODEL : RWS1500B/ME
EN55011A,EN55032A,FCCAの限界値はVCCI class Aの限界値と同じ
Limit of EN55011A,EN55032A,FCCA are same as its VCCI class A.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音端子電圧
Conducted Emission
48VPhase : N
Point A(168kHz)
Ref. Limit MeasureData (dB) (dB)
QP 79.0 51.0
AV 66.0 51.0
Point B(9.9MHz)
Ref. Limit MeasureData (dB) (dB)
QP 73.0 49.8
AV 60.0 48.1
Phase : LPoint C
(169kHz)Ref. Limit Measure
Data (dB) (dB)
QP 79.0 51.6
AV 66.0 51.6
Point D(9.9MHz) Phase : L
Ref. Limit MeasureData (dB) (dB)
QP 73.0 50.3
AV 60.0 47.7
VCCI Class AQP Limit
VCCI Class AAV Limit
VCCI Class AAV Limit
A
C
B
D
VCCI Class AQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 33/40
RWS1500B
MODEL : RWS1500B/ME
EN55011A,EN55032Aの限界値はVCCI class Aの限界値と同じ
Limit of EN55011A,EN55032A are same as its VCCI class A.表示はピーク値
Indication is peak values.
Conditions Vin : 230 VACIout : 100 %Ta : 25 ℃
雑音電界強度
Radiated Emission
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
12V
24V
48V
VCCIClass AQP Limit
VCCIClass AQP Limit
VCCIClass AQP Limit
VCCIClass AQP Limit
VCCIClass AQP Limit
VCCIClass AQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 34/40
RWS1500B219. 無負荷時入力電力、電流 No load input power and current
MODEL : RWS1500B/SInput current vs. Output current Conditions Istb : 0 %
Ta : 25 °C
12V
Input power Input currentIout : 0% Control OFF Iout : 0% Control OFF
90VAC 22.4W 4.2W 90VAC 0.36A 0.23A100VAC 22.2W 4.2W 100VAC 0.37A 0.28A200VAC 21.8W 3.9W 200VAC 0.48A 0.44A265VAC 20.9W 3.9W 265VAC 0.53A 0.49A
24V
Input power Input currentIout : 0% Control OFF Iout : 0% Control OFF
90VAC 25.0W 4.1W 90VAC 0.39A 0.23A100VAC 24.5W 4.1W 100VAC 0.39A 0.28A200VAC 24.6W 4.0W 200VAC 0.48A 0.44A265VAC 23.6W 4.0W 265VAC 0.53A 0.49A
48V
Input power Input currentIout : 0% Control OFF Iout : 0% Control OFF
90VAC 30.6W 4.0W 90VAC 0.48A 0.23A100VAC 30.5W 4.0W 100VAC 0.47A 0.28A200VAC 30.1W 4.0W 200VAC 0.49A 0.44A265VAC 29.4W 3.9W 265VAC 0.54A 0.49A
Vin Vin
Vin Vin
Vin Vin
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 35/40
RWS1500B220. スタンバイ立ち上がり、立ち下がり特性 Standby rise, fall characteristics
MODEL : RWS1500B/SConditions Vin : 100 VAC
Iout : 100 %Istb : 100 %Ta : 25 °C
12Vrise fall
Vout : 5V/DIV Vstb : 5V/DIV Vout : 5V/DIV Vstb : 5V/DIV200ms/DIV 500ms/DIV
24Vrise fall
Vout : 10V/DIV Vstb : 5V/DIV Vout : 10V/DIV Vstb : 5V/DIV200ms/DIV 500ms/DIV
48Vrise fall
Vout : 20V/DIV Vstb : 5V/DIV Vout : 20V/DIV Vstb : 5V/DIV200ms/DIV 500ms/DIV
← 0V →
← Vout →
← Vin →
← Vstb →
← 0V →
← 0V →
← Vout →
← Vin →
← Vstb →
← 0V →
← 0V →
← Vout →
← Vin →
← Vstb →
← 0V →
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 36/40
RWS1500B221. ON/OFFコントロール時出力立ち上がり、立下がり特性
Output rise, fall characteristics with ON/OFF Control
MODEL : RWS1500B/S
Conditions Vin : 100 VACIout : 100 %Istb : 100 %Ta : 25 °C
12Vrise fall
Vout : 5V/DIV Vstb : 5V/DIV Vout : 5V/DIV Vstb : 5V/DIV50ms/DIV 5ms/DIV
24Vrise fall
Vout : 10V/DIV Vstb : 5V/DIV Vout : 10V/DIV Vstb : 5V/DIV50ms/DIV 5ms/DIV
48Vrise fall
Vout : 20V/DIV Vstb : 5V/DIV Vout : 20V/DIV Vstb : 5V/DIV50ms/DIV 5ms/DIV
← 0V →
← Vout →
←ON/OFF→Control
← Vstb →
← 0V →
← 0V →
← Vout →
←ON/OFF→Control
← Vstb →
← 0V →
← 0V →
← Vout →
←ON/OFF→Control
← Vstb →
← 0V →
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 37/40
RWS1500B222. EMI特性 ElectroMagnetic Interference characteristics
MODEL : RWS1500B/S
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
Conditions Vin : 230 VACIout : 100 %Istb : 100 %
雑音端子電圧 Ta : 25 ℃
Conducted Emission
12VPhase : N
Point A(3.6MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 42.0
AV 46.0 41.2
Point B(13.5MHz)
Ref. Limit MeasureData (dB) (dB)
QP 60.0 44.0
AV 50.0 40.9
Phase : LPoint C
(3.9MHz)Ref. Limit Measure
Data (dB) (dB)
QP 56.0 38.0
AV 46.0 35.8
Point D(8.1MHz)
Ref. Limit MeasureData (dB) (dB)
QP 60.0 45.0
AV 50.0 42.00.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
0.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
A
C VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
B
D
VCCI Class BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 38/40
RWS1500B
MODEL : RWS1500B/S
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
Conditions Vin : 230 VACIout : 100 %Istb : 100 %
雑音端子電圧 Ta : 25 ℃
Conducted Emission
24VPhase : N
Point A(164kHz)
Ref. Limit MeasureData (dB) (dB)
QP 65.3 46.0
AV 55.3 45.6
Point B(3.7MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 42.0
AV 46.0 40.5
Phase : LPoint C
(164kHz)Ref. Limit Measure
Data (dB) (dB)
QP 65.3 48.0
AV 55.3 47.1
Point D(3.6MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 41.0
AV 46.0 39.90.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
0.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
A
C VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
B
D
VCCI Class BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 39/40
RWS1500B
MODEL : RWS1500B/S
EN55011B,EN55032B,FCCBの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B,FCCB are same as its VCCI class B.
Conditions Vin : 230 VACIout : 100 %Istb : 100 %
雑音端子電圧 Ta : 25 ℃
Conducted Emission
48VPhase : N
Point A(4.2MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 42.0
AV 46.0 40.1
Point B(13.1MHz)
Ref. Limit MeasureData (dB) (dB)
QP 60.0 44.0
AV 50.0 40.4
Phase : LPoint C
(170kHz)Ref. Limit Measure
Data (dB) (dB)
QP 65.0 45.0
AV 55.0 41.0
Point D(4.2MHz)
Ref. Limit MeasureData (dB) (dB)
QP 56.0 45.0
AV 46.0 43.00.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
0.15 30.000.50 1.00 5.00 10.000
90
10
20
30
40
50
60
70
80
Frequency
Level
[MHz]
[dB(μV)]
A
C VCCI Class BQP Limit
VCCI Class BAV Limit
VCCI Class BAV Limit
B
D
VCCI Class BQP Limit
INSTRUCTION MANUALRWS 50B600B SeriesTDKLambda
TDKLambda 40/40
RWS1500B
MODEL : RWS1500B/S
EN55011B,EN55032Bの限界値はVCCI class Bの限界値と同じ
Limit of EN55011B,EN55032B are same as its VCCI class B.表示はピーク値
Indication is peak values.
Conditions Vin : 230 VACIout : 100 %Istb : 100 %
雑音電界強度 Ta : 25 ℃
Radiated Emission
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
HORIZONTAL VERTICAL
12V
24V
48V
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit
VCCIClass BQP Limit