NOT FOR CONSTRUCTION 2018, Muller & Muller, Ltd. 312.432.4180 312.432.4184 700 N Sangamon Chicago, IL 60642 t f SHEET NO. DRAWN: CHECKED: DESIGNED: JOB NO: KANE COUNTY DEPARTMENT OF TRANSPORTATION (KDOT) OFFICE RENOVATION 41W011 BURLINGTON ROAD CAMPTON HILLS, IL 60175 Professional Seals MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2) C:\Users\vwiegand\Documents\KDOT Office Renovation_vwiegand.rvt 9/27/2018 4:52:18 PM COVER SHEET G-001 V.WIEGAND K.KORAB V.WIEGAND 18-1006 KANE COUNTY DEPARTMENT OF TRANSPORTATION OFFICE RENOVATION 41W011 BURLINGTON ROAD CAMPTON HILLS, IL 60175 100% DESIGN REVIEW KANE COUNTY DEPARTMENT OF TRANSPORTATION A-101 LOWER LEVEL DEMOLITION PLAN AND NEW FLOOR PLAN A-201 FIRST FLOOR PLAN A-301 BUILDING ELEVATIONS, PARTITION TYPES, AND WALL SECTIONS A-701 FIRST FLOOR FINISH PLAN A-702 FIRST FLOOR FURNITURE PLAN A-703 FURNITURE TYPICAL WORKSTATIONS A-801 FIRST FLOOR REFLECTED CEILING PLAN A-900 INTERIOR ELEVATIONS A-902 WINDOW AND DOOR DETAILS G-001 COVER SHEET G-002 ARCHITECTURAL NOTES G-003 ARCHITECTURAL SYMBOLS & ABBREVIATIONS G-004 LIFE SAFETY NOTES & CODE MATRIX DRAWING INDEX LOCATION MAP: KANE COUNTY DEPARTMENT OF TRANSPORTATION E100 FIRST FLOOR LIGHTING DEMOLITION E200 FIRST FLOOR LIGHTING PLANS E300 FIRST FLOOR POWER AND SYSTEMS DEMOLITION E400 LOWER LEVEL ELECTRICAL POWER AND SYSTEMS E401 FIRST FLOOR POWER AND SYSTEMS NEW WORK H001 HEATING AND VENTILATION GENERAL NOTES, SYMBOLS AND ABBREVIATIONS H100 LOWER LEVEL HVAC DEMOLITION PLAN H101 FIRST FLOOR HVAC DEMOLITION PLAN H200 LOWER LEVEL HVAC PLAN H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL MECHANCIAL No. Description Date 1 ISSUED FOR 30% DESIGN 07/23/2018 2 ISSUED FOR 100% DESIGN 09/17/2018 STATEMENT OF COMPLIANCE I have prepared, or caused to be prepared under my supervision, the attached plans and specificiations and state that, to the best of my knowledge and belief and to the extent of my contractual obligation, they are in compliance with the Environmental Barriers Act (III, Rev. Stat. 1985, ch. 111 1/2, pars. 3711 et seq. as amended) and the Illinois Accessibility Code, 71 III. Adm. Code 400. The project will comply with the Illinois Accessibility Code (IAC) Sec. 400.310 (New Construction) and A.D.A.A.G. Title II- All programs, service and activities will be made accessible. Signed Architect/Engineer ILLINOIS REGISTRATION NO.: Date CERTIFICATIONS & SEALS LICENSED ARCHITECT APPLIES TO SHEETS AD-101 THRU AD-801 A-101 THRU A-902 G-001 THRU G-004 LICENSED MECHANICAL ENGINEER APPLIES TO SHEETS H-001THRU H-201 LICENSED ELECTRICAL ENGINEER APPLIES TO SHEETS E-100 THRU E-401 EXPIRES 11/30/2018 THIS CERTIFIES THAT THESE DRAWINGS HAVE BEEN PREPARED UNDER MY DIRECT SUPERVISION AND TO THE BEST OF MY KNOWLEDGE AND BELIEF ARE IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND ORDINANCES. LICENSED ARCHITECT
Transcript
Page 1: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:18

PM

COVER SHEET

G-001V.WIEGANDK.KORABV.WIEGAND

18-1006

KANE COUNTY DEPARTMENT OF TRANSPORTATIONOFFICE RENOVATION

41W011 BURLINGTON ROADCAMPTON HILLS, IL 60175

100% DESIGN REVIEW

KANE COUNTY DEPARTMENT OF TRANSPORTATION

A-101 LOWER LEVEL DEMOLITION PLAN AND NEWFLOOR PLAN

A-201 FIRST FLOOR PLANA-301 BUILDING ELEVATIONS, PARTITION TYPES,

AND WALL SECTIONSA-701 FIRST FLOOR FINISH PLANA-702 FIRST FLOOR FURNITURE PLANA-703 FURNITURE TYPICAL WORKSTATIONSA-801 FIRST FLOOR REFLECTED CEILING PLANA-900 INTERIOR ELEVATIONSA-902 WINDOW AND DOOR DETAILS

G-001 COVER SHEETG-002 ARCHITECTURAL NOTESG-003 ARCHITECTURAL SYMBOLS & ABBREVIATIONSG-004 LIFE SAFETY NOTES & CODE MATRIX

DRAWING INDEXLOCATION MAP:

KANE COUNTY DEPARTMENT OF TRANSPORTATION

E100 FIRST FLOOR LIGHTING DEMOLITIONE200 FIRST FLOOR LIGHTING PLANSE300 FIRST FLOOR POWER AND SYSTEMS

DEMOLITIONE400 LOWER LEVEL ELECTRICAL POWER AND

SYSTEMSE401 FIRST FLOOR POWER AND SYSTEMS NEW

WORK

H001 HEATING AND VENTILATION GENERAL NOTES,SYMBOLS AND ABBREVIATIONS

H100 LOWER LEVEL HVAC DEMOLITION PLANH101 FIRST FLOOR HVAC DEMOLITION PLANH200 LOWER LEVEL HVAC PLANH201 FIRST FLOOR HVAC PLAN

AD-201 FIRST FLOOR DEMOLITION PLANAD-801 FIRST FLOOR DEMOLITION REFLECTED

CEILING PLAN

GENERAL

ARCHTIECTURAL

ELECTRICAL

MECHANCIAL

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

STATEMENT OF COMPLIANCE

I have prepared, or caused to be prepared under my supervision, the attached plans and specificiations and state that, to the best of my knowledge and belief and to the extent of my contractual obligation, they are in compliance with the Environmental Barriers Act (III, Rev. Stat. 1985, ch. 111 1/2, pars. 3711 et seq. as amended) and the Illinois Accessibility Code, 71 III. Adm. Code 400.

The project will comply with the Illinois Accessibility Code (IAC) Sec. 400.310 (New Construction) and A.D.A.A.G. Title II- All programs, service and activities will be made accessible.

SignedArchitect/Engineer

ILLINOIS REGISTRATION NO.:Date

CERTIFICATIONS & SEALS

LICENSEDARCHITECT

APPLIES TO SHEETSAD-101 THRU AD-801

A-101 THRU A-902G-001 THRU G-004

LICENSEDMECHANICAL ENGINEER

APPLIES TO SHEETSH-001THRU H-201

LICENSEDELECTRICAL ENGINEER

APPLIES TO SHEETSE-100 THRU E-401

EXPIRES 11/30/2018

THIS CERTIFIES THAT THESE DRAWINGS HAVE BEEN PREPARED UNDER MY DIRECT SUPERVISION AND TO THE BEST OF MY KNOWLEDGE AND BELIEF ARE IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND ORDINANCES.

LICENSED ARCHITECT

Page 2: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:20

PM

ARCHITECTURAL NOTES

G-002V.WIEGANDK.KORABV.WIEGAND

18-1006

PROJECT GENERAL NOTES - PERMITTING1. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE

GOVERNING EDITION OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE COUNTY, STATE, AND FEDERAL LAWS, INCLUDING THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) AND REGULATIONS ADOPTED PURSUANT THERETO.

2. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR APPLYING, PROCURING, AND PAYING FOR ALL PERMITS AND INSPECTIONS REQUIRED TO COMPLETE THE SCOPE OF WORK UNLESS NOTED OTHERWISE.

3. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND PERMITTING (INCLUDING PERMIT COSTS) OF ALL SHORING NECESSARY TO IMPLEMENT THE DESIGN.

PROJECT GENERAL NOTES - BIDDING1. PRIOR TO SUBMISSION OF BID, GENERAL CONTRACTOR SHALL VISIT THE SITE AND BE

KNOWLEDGEABLE OF ALL CONDITIONS THEREON, HE OR SHE SHALL INVESTIGATE, VERIFY, AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE PROJECT AND SHALL NOTIFY THE OWNER OF ANY CONDITIONS REQUIREMENT MODIFICATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS, AND TECHNIQUES TO IMPLEMENT THE DESIGN AS PART OF THEIR BASE BID.

2. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO RELATED DRAWINGS AND DETAILS. WHEN THERE ARE DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS, CONSULT THE OWNER DURING THE BID PERIOD FOR ANY CLARIFICATIONS NEEDED PRIOR TO SUBMISSION OF BID. IF THE OWNER IS NOT CONSULTED DURING THE BID PERIOD, THE MORE STRINGENT REQUIREMENT SHALL APPLY.

3. ASBESTOS WARNING: ASBESTOS-CONTAINING MATERIALS ARE OR MAY BE PRESENT IN THIS BUILDING. NO PERSON MAY DISTURB ASBESTOS - CONTAINING BUILDING MATERIALS UNLESS THAT PERSON IS A LICENSED ASBESTOS WORKER AND CONDUCTS SUCH WORK IN ACCORDANCE WITH SECTIONS CONTAINED IN THE PROJECT DOCUMENTS AND IN COMPLIANCE WITH ILLINOIS DEPARTMENT OF PUBLIC HEALTH RULES AND REGULATIONS.

4. THE INTERIOR AND EXTERIOR PAINTED SURFACES SHALL BE PRESUMED TO CONTAIN LEAD-BASED PAINT. DISTURBANCES OF THESE PAINTED SURFACES TO COMPLETE THE REQUIRED SCOPE SHALL BE CONDUCTED IN ACCORDANCE WITH USEPA'S FINAL RENOVATION, REPAIR, AND PAINTING (RRP) RULE IN 40 CFR 745. ALL LEAD-SAFE WORK PRACTICES INCLUDE, BUT ARE NOT LIMITED TO ISOLATING THE WORK AREA TO PREVENT DUST MIGRATION, MINIMIZING DUST GENERATION, ENSURING ALL PERSONNEL AND EQUIPMENT ARE FREE OF DUST BEFORE LEAVING THE WORK AREA, CLEANING THE AREA AFTER WORK IS COMPLETED.

5. THE SUBMISSION OF A BID OR PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND EXISTING CONDITIONS OF THE BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION OF THE SITE AND/OR DRAWINGS BEEN MADE.

PROJECT GENERAL NOTES - CONSTRUCTION1. ALL DIMENSIONS ARE TO FACE OF PARTITIONS, COLUMN CENTERLINE, OR FINISHED

FACE OF EXTERIOR WALL UNLESS OTHERWISE NOTED.

2. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE PROCEEDING WITH ANY WORK. THE OWNER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR CORRECTIONS. DIMENSIONS OF NEW WORK ARE BASED ON RECORD DRAWINGS OF EXISTING WORK. ANY DISCREPANCIES IN EXISTING WORK WILL AFFECT NEW WORK DIMENSIONS. CONTRACTOR IS TO VERIFY THE DIMENSIONS.

3. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR MECHANICAL AND ELECTRICAL EQUIPMENT. REVIEW LOCATIONS WITH OWNER AND ARCHITECT, AT A PRE-INSTALLATION CONFERENCE.

4. FIRE-STOP ALL PENETRATIONS IN WALLS TO MATCH HOURLY RATING OF THE WALL.

5. ALL NON-RATED PARTITION WALLS SHALL BE STOPPED AND/OR CALKED AT TOP, BOTTOM, AND ADJACENT ASSEMBLIES WITH 1-HOUR EQUIVALENT FIRESTOPPING AND SEALANTS. SEAL ALL PENETRATIONS.

6. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED.

7. THE CONTRACTOR MUST COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR SLEEVES AND WALL SLEEVES, EMBEDDED CONDUIT, AND MECHANICAL DUCTWORK WITH MECHANICAL, PLUMBING, ELECTRICAL, AND ARCHITECTURAL DRAWINGS WITH CORRESPONDING DISCIPLINES.

8. ALL PIPES, CONDUITS, AND DUCTWORK THAT PENETRATE WALLS, FLOOR, OR ROOF SLABS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE FIRE RESISTIVE INTEGRITY AND WATER TIGHTNESS OF SUCH WALLS OR SLABS AND THE BUILDING.

9. ALL EXTERIOR JOINTS AROUND WINDOWS, DOORS, FRAMES, METAL PANELS, BETWEEN WALLS AND ROOF, BETWEEN WALL PANELS, AND AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE SHALL BE FIRE-SAFE AS REQUIRED, SEALED, CAULKED, OR WEATHER STRIPPED TO PREVENT WATER OR AIR LEAKAGE/PENETRATION.

10. TOP OF FLOOR SLAB AT GROUND FLOOR = 0'-0".

11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING AND NEW WORK. ANY WORK DAMAGED FOR ANY REASON SHALL BE REPLACED AT NO COST TO THE OWNER.

12. PRIOR TO STARTING CONSTRUCTION THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NEITHER CONSTRUCTION NOR FABRICATION OF ANY ITEM SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED ALL PLANS AND ANY OTHER APPROVALS FROM GOVERNMENTAL AGENCIES OR OTHER REGULATORY AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. FAILURE OF THE CONTRACTOR TO FOLLOW THIS PROCEDURE SHALL CAUSE THE CONTRACTOR TO ASSUME FULL RESPONSIBILITY FOR ANY SUBSEQUENT MODIFICATION OF THE WORK MANDATED BY REGULATORY AUTHORITY.

13. ALL GYPSUM BOARD TO BE 5/8" TYPE "X" UNLESS NOTED OTHERWISE. IN DAMP AREAS, MOISTURE AND MOLD RESISTANT GYPSUM BOARD SHALL BE USED IN LIEU OF REGULAR GYPSUM BOARD. IN WET AREAS CEMENTITIOUS BACKER UNITS SHALL BE USED.

14. INSTALL GYPSUM BOARD CONSTRUCTION JOINTS AT MINIMUM 30'-0" O.C.

15. CONTRACTOR SHALL INSTALL ROUGH BLOCKING OR WOOD NAILERS DURING THE ROUGH FRAMING STAGE OF CONSTRUCTION AS REQUIRED FOR PROPERLY SECURING WALL CABINETS, SHELVING, LIGHTING, AND ELECTRICAL FIXTURES, WALL MOUNTED EQUIPMENT, MILLWORK, APPLIED DECORATIVE TREATMENTS, AND HANDRAIL BRACKETS. ALL WOOD BLOCKING TO BE FIRE TREATED MATERIAL.

16. EXISTING AREAS DAMAGED BY WORK OF THIS PROJECT SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES IN FINISH, COLOR, AND TEXTURE UNLESS OTHERWISE NOTED.

17. EXISTING PAINTED SURFACES DAMAGED OR PATCHED AS PART OF THIS PROJECT SHALL BE PAINTED TO MATCH EXISTING ADJACENT FINISH, COLOR, AND TEXTURE. EXISTING PAINT FINISH, COLOR, AND TEXTURE SHALL BE VERIFIED BY CONTRACTOR IN THE FIELD PRIOR TO CONSTRUCTION.

18. NEWLY INSTALLED EXPOSED ELECTRICAL ITEMS, INCLUDING BUT NOT LIMITED TO, CONDUIT HANGERS, AND FITTINGS SHALL BE PAINTED TO MATCH EXISTING ADJACENT SURFACES UNLESS DRAWINGS INDICATE A WALL OR CEILING TO REMAIN UNFINISHED (NOT PAINTED).

19. ALL EXISTING FLOOR SURFACES DAMAGED OR PATCHED AS PART OF THIS PROJECT SHALL BE PATCHED TO MATCH EXISTING ADJACENT FINISH, COLOR, AND TEXTURE. EXISTING FLOOR FINISH SHALL BE VERIFIED AND DOCUMENTED BY CONTRACTOR IN THE FIELD PRIOR TO CONSTRUCTION.

20. ALL NEW CMU AND EXPOSED CONCRETE WALLS TO BE CLEANED AND PAINTED UNLESS NOTED OTHERWISE.

21. CONTRACTOR TO REMOVE ANY GRAFFITI WITHIN 24 HOURS DURING CONSTRUCTION.

PROJECT GENERAL NOTES - SCOPE1. THIS PROJECT GENERALLY CONSISTS OF A RENOVATION FOR OFFICE SPACE

IMPROVEMENTS APPROXIMATELY 1,700 SQUARE FEET. WORK WILL BE LIMITED TO THE MAIN LEVEL OF THE ORIGINAL PORTION OF THE OFFICE BUILDING, THERE IS NO SCOPE IN THE NEWER ADDITION SPACE.

PROJECT GENERAL NOTES - DEMOLITION1. DEMOLISH ALL ITEMS NOTED AND IN SCOPE OF WORK NOTES. CONTRACTOR IS

RESPONSIBLE FOR COMPLETE REMOVAL OF ALL ITEMS ASSOCIATED WITHIN THE DEMOLISHED AREA.

2. CONTRACTOR SHALL VISIT THE SITE AND FULLY REVIEW CONDITIONS AND QUANTITIES OF THIS BUILDING AND SITE PRIOR TO BID SUBMISSION TO GAIN FULL KNOWLEDGE OF THE DEMOLITION REQUIREMENTS. HE OR SHE SHALL INVESTIGATE, VERIFY, AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE PROJECT AND SHALL NOTIFY THE OWNER OF ANY CONDITIONS REQUIRING MODIFICATION DURING THE BID PERIOD. ALL DEMOLITION FOR THE PROJECT (INCLUDING REQUIRED PERMITS), EXCEPT SPECIFIC ITEMS NOTED AS N.I.C.

3. TO THE BEST OF THE OWNERS KNOWLEDGE THESE DRAWINGS REPRESENT THE EXISTING PLAN CONDITIONS TO BE REMOVED AS ARE DIAGRAMMATICALLY SHOWN. EXACT LOCATIONS, SIZES, EXTENT, AND CONDITIONS OF EXISTING CONSTRUCTION TO BE REMOVED, RELOCATED, OR TO REMAIN SHALL BE VERIFIED AT THE BUILDING SITE BY THE CONTRACTOR. CONTRACTOR TO REPORT DISCREPANCIES IN WRITING DURING THE BID PERIOD.

4. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT BUILDING CODE AND ALL APPLICABLE COUNTY, STATE, AND FEDERAL LAWS, INCLUDING THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) AND REGULATIONS ADOPTED PURSUANT THERETO.

5. CONTRACTOR TO PERFORM DEMOLITION SCOPE OF WORK AS REQUIRED TO COMPLETE NEW CONSTRUCTION. COORDINATE ARCHITECTURAL DEMOLITION WITH MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DEMOLITION SCOPE OF WORK.

6. ITEMS OF CONSTRUCTION SHOWN AND NOTED TO BE REMOVED SHALL BE THE SAME FOR ALL SIMILAR CONDITIONS AND CONSTRUCTION UNLESS NOTED OTHERWISE.

7. SALVAGED ITEMS REQUESTED BY THE OWNER MUST BE CAREFULLY REMOVED, KEPT FREE OF DAMAGE, AND DELIVERED TO THE DESIGNATED STORAGE AREA. MATERIALS AND/OR ITEMS REMOVED AND NOT DESIGNATED TO BECOME THE PROPERTY OF THE OWNER WILL BECOME PROPERTY OF THE CONTRACTOR AND REMOVED FROM SITE.

8. ANY EXISTING COMPONENT REMOVED OR DAMAGED TO ALLOW NEW WORK TO OCCUR MUST BE REINSTALLED OR REPLACED AT THE COMPLETION OF NEW WORK UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL INCLUDE THE SATISFACTORY PATCHING AND FINISH OF ALL SCARS RELATED TO THE DEMOLITION OPERATION.

9. ALL ITEMS OF DEMOLITION NOT INDICATED TO BE SAVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL ASSOCIATED MACHINERY, FRAMING, ANCHORS, HOUSING, ETC. AND BE DISPOSED OF ON A DAILY BASIS TO AVOID ACCUMULATION OF ANY DEBRIS ON THE SITE.

10. REMOVE ALL EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS NOT UTILIZED IN THE NEW CONSTRUCTION.

11. PATCH ALL PENETRATIONS RESULTING FROM THE REMOVAL OF UTILITIES. MAINTAIN REQUIRED FIRE RATING WHERE WALLS ARE PATCHED. FINISH TO MATCH ADJACENT SUBSTRATE.

12. DO NOT CUT INTO, REMOVE, OR ALTER ANY EXISTING STRUCTURAL MEMBER OR PORTION OF THE FLOOR SYSTEM UNLESS NOTED OTHERWISE.

13. SUBMIT WRITTEN REQUEST TO OWNER IN ADVANCE OF CUTTING OR ALTERING ELEMENTS WHICH AFFECT;A. STRUCTURAL INTEGRITY OF ELEMENT.B. INTEGRITY OF WEATHER-EXPOSED OR MOISTURE-RESISTANT ELEMENTS

16. THE GC SHALL SAW CUT ALL MASONRY WALLS, CONCRETE FLOORS, AND CONCRETE WALLS IN A CLEAN AND STRAIGHT MANNER, AT THE LIMITS OF THE DESIGNATED REMOVAL.

17. REFER TO MECHANICAL DRAWINGS FOR THE REMOVAL AND/OR REUSE OF ALL MECHANICAL DIFFUSERS, DUCTWORK, EQUIPMENT, ETC.

18. REFER TO ELECTRICAL DRAWINGS FOR THE REMOVAL AND/OR REUSE OF ALL ELECTRICAL COMPONENTS.

19. CLEAN ALL EXCESS CONCRETE SPOTS, SOLID DEBRIS, AND PAINT SPOTS FROM THE FLOOR. REMOVE ALL WAX, DIRT, GREASE, PAINTS, AND OLD ADHESIVES.

20. CRACKS, HOLES, AND DEPRESSIONS IN THE FLOORING SYSTEM TO BE FILLED USING PATCHING MATERIAL ACCEPTABLE TO FLOORING MANUFACTURER. SWEEP AND VACUUM THE FLOOR AFTER PATCHING AND DEBRIS REMOVAL. DO NOT USE OIL BASED SWEEPING COMPOUNDS. MAKE SURE ALL PERIMETER AREAS ARE CLEAN.

21. WHERE EXISTING CONCRETE SLABS ARE REMOVED FOR THE INSTALLATION OF PLUMBING OR ELECTRICAL SYSTEMS, PATCH EXISTING MATERIALS AS REQUIRED TO MEET FIRE RATING REQUIREMENTS.

22. REMOVE DEBRIS AND ABANDONED ITEMS FROM THE CONSTRUCTION AREA. CAP ALL REMAINING PIPING AS REQUIRED BY CODE.

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

Page 3: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

FD

101D DOOR NUMBER DOOR TAG

PARTITION TYPE PARTITION TAG2A-3

ACCESSORY NUMBER

ACCESSORY TAG

GLAZING TAGGLAZING TYPEGL-1

SIGN NUMBER SIGNAGE TAG

## EQUIPMENT NUMBER

EQUIPMENT TAG

##

S##

## PLUMBING FIXTURE NUMBER

PLUMBING FIXTURE TAG

FLOOR DRAIN; REF PLUMB DWGS

GRAPHIC SCALE

SEALANT & BACKER ROD

WEATHER RESISTIVE BARRIER

SCALE: 1" = 30'-0"

060' 30' 15'

C.J.

CONTROL JOINT

1 HOUR RATED PARTITION

2 HOUR RATED PARTITION

3 HOUR RATED PARTITION

4 HOUR RATED PARTITION

FE FIRE EXTINGUISHER

5' WHEELCHAIR TURNAROUND

DIVISION 03 - CONCRETE

CONCRETE

PRECAST CONCRETE

DIVISION 04 - MASONRY

BRICK

STONE

CONCRETE MASONRY UNIT (CMU)

MORTAR NET

STRUCTURAL GLAZED FACING TILE (SGFT)

DIVISION 05 - METALS

ALUMINUM

STEEL

DIVISION 06 - WOODS, PLASTICS AND COMPOSITES

BLOCKING / SHIM

DIMENSIONAL LUMBER

FINISH WOOD

PLYWOOD

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

FIREPROOFING

INSULATION - BATT

INSULATION - RIGID

DIVISION 08 - OPENINGS

GLAZING (LARGE SCALE)

DIVISION 09 - FINISHES

ACOUSTICAL CEILING TILE (ACT)

CERAMIC TILE (WALL OR FLOOR)

GYPSUM WALL BOARD (GWB)

RESILIENT TILE

SOLID SURFACE MATERIAL (SSM)

TERRAZZO

DIVISION 31 - EARTHWORK

EARTH

GRAVEL

DIVISION 32 - SITE IMPROVEMENTS

TACTILE WARNING

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:22

PM

ARCHITECTURALSYMBOLS &ABBREVIATIONS

G-003V.WIEGANDK.KORABV.WIEGAND

18-1006

GENERAL SYMBOL LEGEND

P PLSTR PLASTERP PLUMB PLUMBINGP PNL PANELP POU POINT OF USEP PR PAIRP PRC PRECASTP PREFAB PREFABRICATE(D)P PT(D) PAINT(ED)P PTN PARTITIONP PVC POLYVINYL CHLORIDEP PWD PLYWOOD

Q QT QUARRY TILE

R RB RESILIENT BASER RCP REFLECTED CEILING PLANR RD ROOF DRAINR REF REFERENCER REINF REINFORCED(D)(ING)R REQD REQUIREDR RH RIGHT HANDR RM ROOMR RO ROUGH OPENINGR ROW RIGHT-OF-WAYR RSR RISERR RTN RETURN

S SAN SANITARYS SC SEALED CONCRETES SCFT STRUCTURAL CLAY FACING TILES SCHED SCHEDULES SCWD SOLID CORE WOOD DOORS SF SQUARE FEET(FOOT)S SFCMU SPLIT FACE CONCRETE MASONRY UNITS SHT SHEETS SHWR SHOWERS SIM SIMILARS SPEC(S) SPECIFICATION(S)S SQ SQUARES ST STL STAINLESS STEELS STL STEELS STN STONES STRUC STRUCTURE/STRUCTURALS SUSP SUSPENDED

T T&G TONGUE AND GROOVET T/ TOP OFT TD TRENCH DRAINT TEL TELEPHONET TEMP TEMPORARYT THK THICK(NESS)T TRD TREADT TYP TYPICALT TZ TERRAZZO

U UL UNDERWRITER'S LABORATORIESU UNF UNFINISHEDU UNO UNLESS NOTED OTHERWISEU UNX UNEXCAVATEDU URN URINAL

V VB VINYL BASEV VCT VINYL COMPOSITION TILEV VERT VERTICAL(LY)V VIF VERIFY IN FIELDV VTR VENT THROUGH ROOF

W W/ WITHW WAP WIRELESS ACCESS POINTW WC WATER CLOSETW WD WOODW WGT WEIGHTW WH WALL HUNGW WM WIRE MESHW WP WORKING POINTW WR WATER RESISTANTW WRB WEATHER RESISTIVE BARRIERW WWF WELDED WIRE FABRIC

G GA GAUGEG GALV GALVANIZEDG GB GYPSUM BOARDG GC GENERAL CONTRACTORG GCMU GLAZED CONCRETE MASONRY UNITG GFCI GROUND FAULT CIRCUIT INTERRUPTERG GFCMU GROUND FACE CONCRETE MASONRY UNITG GFRC GLASS FIBER REINFORCED CONCRETEG GFRG GLASS FIBER REINFORCED GYPSUMG GL GLASS

H HB HOSE BIBH HC HOLLOW COREH HDW HARDWAREH HM HOLLOW METALH HORIZ HORIZONTAL(LY)H HP HIGH POINTH HR(S) HOUR(S)H HT HEIGHTH HVAC HEATING, VENTILATING, AND AIR

CONDITIONINGH HW HOT WATERH HWD HARDWOODH HWH HOT WATER HEATER

I ID INSIDE DIAMETERI IN INCH(ES)I INCL INCLUDE(D)(ING)I INFO INFORMATIONI INSUL INSULATIONI INT INTERIOR, INTERNAL

J JAN JANITORJ JST JOISTJ JT JOINT

L LAM LAMINATE(D)L LAV LAVATORYL LBP LEAD-BASED PAINTL LBS POUND(S)L LF LINEAR FEETL LH LEFT HANDL LLH LONG LEG HORIZONTALL LLV LONG LEG VERTICALL LP LOW POINTL LVL LEVEL

M MATL MATERIAL(S)M MAX MAXIMUMM MECH MECHANICALM MEP MECHANICAL, ELECTRICAL & PLUMBINGM MEZZ MEZZANINEM MFR MANUFACTURER(R)(D)M MH MANHOLEM MIN MINIMUMM MISC MISCELLANEOUSM MNT MOUNT(ING)M MO MASONRY OPENINGM MOPD MAYOR'S OFFICE FOR PEOPLE WITH

DISABILITIESM MTD MOUNTEDM MTL METALM MWK MILLWORK

N NIC NOT IN CONTRACTN NO NUMBERN NOM NOMINALN NTS NOT TO SCALE

O OC ON CENTERO OCC OCCUPANCYO OD OUTSIDE DIAMETERO OHD OVERHEAD DOORO OPH OPPOSITE HANDO OPNG OPENINGO OPP OPPOSITE

P PCT PORCELAIN CERAMIC TILEP PHEN PHENOLICP PJF PREMOLDED JOINT FILLERP PL PLATEP PLAM PLASTIC LAMINATE

A AC AIR CONDITIONINGA ACT ACOUSTIC CEILING TILEA ADA AMERICANS WITH DISABILITIES ACTA ADJ ADJACENTA AFF ABOVE FINISHED FLOORA ALUM ALUMINUMA APPROX APPROXIMATELYA ARCH ARCHITECTURAL

B B/ BOTTOM OFB BIT BITUMINOUSB BLDG BUILDINGB BRK BRICKB BTW BETWEEN

C CAB CABINETC CB CEMENT BOARDC CCD CHICAGO CITY DATUMC CFMF COLD FORMED METAL FRAMINGC CI CONTINUOUS INSULATIONC CIP CAST IN PLACEC CJ CONTROL JOINTC CL CENTERLINEC CLNG CEILINGC CLO CLOSETC CLR CLEAR(ANCE)C CMU CONCRETE MASONRY UNITC CO CLEAN OUTC COL COLUMNC COMM COMMUNICATION(S)C CONC CONCRETEC CONST CONSTRUCTIONC CONT CONTINUOUSC CORR CORRIDORC CPT CARPETC CRS COURSE(S)C CS CAST STONEC CT CEREMIC TILEC CW COLD WATERC STC SOUND TRANSMISSION CLASS

D DBL DOUBLED DEMO DEMOLISH, DEMOLITIOND DF DRINKING FOUNTAIND DIA DIAMETERD DIM DIMENSIOND DN DOWND DS DOWNSPOUTD DWG(S) DRAWING(S)

E EA EACHE EJ EXPANSION JOINTE ELEC ELECTRICALE ELEV ELEVATIONE ELVR ELEVATORE ENCL ENCLOSUREE ENT ENTRANCEE EOS EDGE OF SLABE EP EPOXY PAINTE EQ EQUALE EQUIP EQUIPMENTE ESCR ESCALATORE EWC ELECTRIC WATER COOLERE EWH ELECTRIC WATER HEATERE EXH EXHAUSTE EXIST EXISTINGE EXP EXPOSEDE EXT EXTERIOR

F F/ FACE OFF FAAP FIRE ALARM ANNUNCIATOR PANELF FACP FIRE ALARM CONTROL PANELF FD FLOOR DRAINF FDN FOUNDATIONF FE FIRE EXTINGUISHERF FEC FIRE EXTINGUISHER CABINETF FF FINISHED FLOORF FIN FINISH(ED)F FLR FLOORF FP FIRE PROTECTIONF FT FEET, FOOTF FTG FOOTING

PROJECT ABBREVIATIONS PROJECT PATTERNS

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

Page 4: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

TRAVEL DISTANCE = 82' - 4"

OFFICE101

102ENTRY100

BREAK OUT

TRAVEL DISTANCE = 41' - 4"

EXISTING EXIT - NO CHANGE(1) 36" EXIT WIDTHS32"/.2" = 160 PERSONS CAPACITY

STAIR #1E

OFFICEE OFFICE

E

BOOKKEEPINGE

OFFICEE

OFFICEE

LOBBYE

BREAK ROOME

WOMEN'SE

MEN'SE

CONFERENCEROOM

E

LOBBYE OFFICE

EELEVATORE

MEN'SE

WOMEN'SE

CONTROL ROOME

CONFERENCEROOM

E

OFFICEE

TEST LABE

OFFICEE

OFFICEE

123 SF / 100 =2 PERSONS

115 SF / 100 =2 PERSONS

197 SF / 300 =1 PERSONS

167 SF / 100 =2 PERSONS

312 SF / 100 =4 PERSONS

735 SF / 300 =3 PERSONS

194 SF / 100 =2 PERSONS

342 SF / 100 =4 PERSONS

272 SF / 100 =3 PERSONS

245 SF / 100 =3 PERSONS

410 SF / 100 =5 PERSONS

133 SF / 100 =2 PERSONS

107 SF / 100 =2 PERSONS

478 SF / 100 =5 PERSONS

125 SF / 100 =2 PERSONS

1087 SF / 100 =11 PERSONS

EXISTING EXIT - NO CHANGE(1) 36" EXIT WIDTHS32"/.2" = 160 PERSONS CAPACITY

1 HR

2 H

R

EXISTING EXIT - NO CHANGE(2) 36" EXIT WIDTHS70"/.2" = 350 PERSONS CAPACITY

OFFICE AREAE

MECHANICALROOM

E

EQUIPMENTROOM

E

ELECTRICALROOM

E

STORAGEEELEVATOR

E

SHOWERROOM

E

STORAGEE

UNISEXE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

MECHANCIALESTAIR 1

E

UP

UP

UP

STORAGEE

1159 SF / 300 =4 PERSONS

485 SF / 300 =2 PERSONS

578 SF / 300 =2 PERSONS

317 SF / 300 =2 PERSONS

214 SF / 300 =1 PERSONS

167 SF / 300 =1 PERSONS

2394 SF / 300 =8 PERSONS

1079 SF / 100 =11 PERSONS

191 SF / 300 =1 PERSONS

113 SF / 300 =1 PERSONS

107 SF / 300 =1 PERSONS

266 SF / 300 =1 PERSONS

258 SF / 300 =1 PERSONS

NO CHANGE, N.I.C.

1. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A WITH A FLAME SPREAD RATING 0-25, AND SMOKE DEVELOPED MAX RATING OF 450 PER IBC 803.1.1.

2. ALL EXIT DOORS TO SWING IN THE DIRECTION OF TRAVEL EXCEPT FROM ROOMS HAVING A CAPACITY NOT EXCEEDING 50 PERSONS, PER IBC 1008.1.2.

3. ALL EXIT DOORS MUST BE READILY OPENED WITHOUT A KEY FROM THE SIDE EGRESS IS MADE, PER IBC 1008.1.9.

4. SEE SHEET A-201 FOR PARTITION TYPES.5. ALL GLASS IN DOORS TO BE TEMPERED SAFETY GLASS AND SAFETY RATED GLASS

ADJACENT TO DOORS.6. ALL FIRE RATINGS INDICATED FOR WALLS, CEILINGS, AND ROOF ARE TO COMPLY

WITH UNDERWRITER'S LABORATORIES TEST RATINGS OR AS REGULATED BY THE INTERNATIONAL BUILDING CODE AND NFPA 130 (2014).

7. ALL GYPSUM BOARD TO BE TYPE 'X' UNLESS NOTED OTHERWISE.8. ALL RATED DOORS TO HAVE A FIRE DOOR CERTIFICATION LABEL READILY VISIBLE

BY THE AUTHORITY HAVING JURISDICTION, MUST BE SELF-CLOSING AND MUST HAVE A POSITIVE LATCH, AND MUST BE INSTALLED IN ACCORDANCE WITH NFPA-80.

9. MECHANICAL, ELECTRICAL, AND STORAGE AREAS REQUIRE TO HAVE 1HR SPRAY APPLIED FIRE PROTECTION AT ROOF AND STRUCTURE SUPPORTING ROOF. IF ABOVE 20'-0" AFF, NOT REQUIRED.

10. ALL PENETRATIONS IN NONFIRE-RESISTANCE-RATED FLOOR ASSEMBLIES SHALL BE PROTECTED WITH AN APPROVED NONCOMBUSTIBLE MATERIAL THAT RESISTS THE FREE PASSAGE OF FLAME AND THE PRODUCTS OF COMBUSTION PER IBC 717.6.3.

GENERAL NOTES - LIFE SAFETY

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:25

PM

LIFE SAFETY NOTES &CODE MATRIX

G-004V.WIEGANDK.KORABV.WIEGAND

18-1006

3/32" = 1'-0"1FIRST FLOORLIFE SAFETY PLAN

3/32" = 1'-0"2BASEMENT FLOORLIFE SAFETY PLAN

CODE MATRIX

N N

SCALE: 3/32" = 1'-0"

024' 12' 6'

PLUMBING FIXTURE COUNTS - NO CHANGE TO EXISTINGTOTAL OCCUPANT LOAD = 89 PERSONS

PLUMBING FIXTURE REQ'D ACCORDING TO ILLINOIS PLUMBING CODE SECTION 890 APPENDIX A, TABLE B: OFFICE BUILDINGS

WATER CLOSETS REQUIREDMEN 35 - 55 = 3WOMEN 35 - 55 = 3PROVIDED = 9 MENS ROOM

5 WOMENS ROOM 1 UNISEX

TOTAL = 15

LAVATORIES REQUIREDMEN 36 - 60 = 3WOMEN 36 - 60 = 3PROVIDED = 3 MENS ROOM

5 WOMENS ROOM 1 UNISEX

TOTAL = 9

PLUMBING FIXTURE COUNTS PROVIDED ARE IN COMPLIANCE

PARKING DATA - NO CHANGE TO EXISTINGTOTAL PARKING STALLS PROVIDED ON BUILDING PROPERTY: 46 (NO CHANGE)

2 HC SPACES (NO CHANGE)TOTAL: 70 PROVIDED

PARKING CAPACITIES PROVIDED ARE IN COMPLIANCE

OCCUPANCY LOAD CALCULATIONSAREA CALCULATION METHOD

FIRST FLOOR : 36 OCC.LOWER LEVEL: 53 OCC.TOTAL INDOOR 89 OCC.

EXITING CALCULATIONS - NO CHANGE TO EXISTING3 EXITS = 670 OCCUPANTS ALLOWABLE FOR EXITING

DOOR CAPACITY(1) 36" EXIT WIDTHS

32"/0.2IN = 160 OCC.

(1) 36" EXIT WIDTHS32"/0.2IN= 160 OCC.

(2) 36" EXIT WIDTHS70"/0.2" = 350 OCC

TOTAL 670 OCC ALLOWABLE

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

Page 5: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

OFFICE101

102

EXISTING FILEVAULT

131

EXISTINGOFFICE

EXISTING

REMOVE DOOR AND FRAME TO BE INFILLED

REMOVE DOOR AND FRAME TO BE INFILLED

REMOVE CMU WALL INCLUDING WALL BASE

REMOVE DOOR AND FRAME

REMOVE DOOR AND FRAME TO BE INFILLED

REMOVE FINISH FLOORING TO ORIGINAL CONCRETE SLAB

REMOVE PORTION OF WALL FOR NEW STOREFRONT TO ROOF DECK

REMOVE PORTION OF WALL FOR NEW WINDOW OPENING

REMOVE PORTION OF WALL FOR NEW WINDOW OPENING

REMOVE WALL BASE, TYP

ENTRY100

N.I.C.

REMOVE FINISH FLOORING TO ORIGINAL CONCRETE SLAB

REMOVE ALL PERIMETER FLOOR VENT REGISTERS AND PATCH EXISTING OPENINGS IN SLAB, TYP

REMOVE ALL PERIMETER FLOOR VENT REGISTERS, TYP

REMOVE FINISH FLOORING TO ORIGINAL CONCRETE SLAB

REMOVE MAGNETIC HOLD-OPEN AT FLOOR, REF ELEC DWGS

M.O.

4'-0"

MASONRY COURSING; REF DETAIL 2/AD-201ALIGN MASONRY OPENING WITH

REMOVE EXISTING AUDIO/VISIUAL EQUIPMENT FOR REINSTALLATION, REF ELECTRICAL DWGS

REMOVE DOWNSPOUTS TO BE RELOCATED

STAIR #1E

OFFICEE

LOCKERSE

OFFICEE

BOOKKEEPINGE

OFFICEE

BREAK ROOME

WOMEN'SE

MEN'SE

REMOVE EXISTING INTERIOR WOOD CASING, TYP OF 4 WINDOWS

REMOVE EXISTING VERTICAL BLINDS FOR REINSTALLATION, TYP OF 4 WINDOWS

44' - 10" VIF 23' - 0" VIF

M.O.

4' - 0"

M.O.

4' - 0"

ALIGN WITH EDGE OF BEAM ABOVE ALIGN WITH EDGE OF

BEAM ABOVE24

' - 0

1/2

" VIF

10' -

8" V

IF

12' - 2" VIF

CL CLCLCLCL

14' - 0"TYP

6"

4' -

4 1/

2"

CUT SLAB OPENINGS FOR NEW 12"X4" VENTS, TYP. COORDINATE SLAB OPENINGS WITH JOIST FRAMING.

FE

REMOVE FIRE EXTINGUISHER TO BE RELOCATED AND REINSTALLED

10' - 9"

12' - 4 3/4"16' - 4"

AD-2012

1. CONTRACTOR TO COORDINATE ALL REMOVAL WITH THE REQUIREMENTS OF NEW CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF ALL ITEMS ASSOCIATED WITHIN THE DEMOLISHED AREA.

2. WALLS TO BE REMOVED ARE TO BE REMOVED TO THE DECK, U.N.O. CONTRACTOR TO VERIFY CEILING HEIGHTS IN THE FIELD DURING BIDDING.

3. REFERENCE MECH., AND ELEC. DEMO DRAWINGS FOR ASSOCIATED DEMO SCOPE.

4. OWNER WILL REMOVE AND/OR RELOCATE ALL EXISTING FURNITURE, FILE CABINETS, STORAGE, SHELVING, ETC PRIOR TO CONSTRUCTION.

5. REMOVE AUDIO/VISUAL AND EXIT SIGNS FOR REPLACEMENT; REFER TO ELECTRICAL DWGS.

6. SCOPE OF WORK CONTAINS SUSPECT LOCATIONS OF HAZARDOUS BUILDING MATERIALS. ABATEMENT IN LOCATIONS CONTAINING HAZARDOUS BUILDING MATERIALS IS REQUIRED. CONTRACTOR TO COMPLY WITH PROPER REMOVAL/MITIGRATION PROCEDURES AS REQUIRED

GENERAL NOTES - DEMO PLANS

EDGE OF MASONRY OPENING

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:14

PM

FIRST FLOORDEMOLITION PLAN

AD-201V.WIEGANDK.KORABV.WIEGAND

18-1006

N

1/4" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

08' 4' 2'

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

N.T.S.2BREAK OUT ROOMEXISTING INTERIOR ELEVATION

Page 6: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

AP

AP

REMOVE SUSPENDED GYP CEILING AND FRAMING TO EXPOSE WOOD DECK. REMOVE ALL EXPOSED MECHANICAL AND ELECTRICAL ROUTING INCLUDING BUT NOT LIMITED TO CONDUITS.

REMOVE EXISTING LIGHT FIXTURES, TYP

REMOVE EXISTING LIGHT FIXTURES, TYP

OFFICE101

102

ENTRY100

EXISTINGOFFICE

EXISTING

LINE OF ROOF ABOVE

EXISTING FINISHED CEILING TO REMAIN

REMOVE SUSPENDED GYP CEILING, ACOUSTIC TILES AND FRAMING

REMOVE EXISTING LIGHT FIXTURES, TYP

ACCESS PANEL TO BE REMOVED AND SALVAGE FOR REINSTALLATION

N.I.C.ACCESS PANEL TO BE REMOVED AND SALVAGE FOR REINSTALLATION

REMOVE DOWNSPOUTS TO BE RELOCATED

EXISTING BEAMS

STAIR #1E

OFFICEE

LOCKERSE

OFFICEE

BOOKKEEPINGE

OFFICEE

BREAK ROOME

WOMEN'SE

MEN'SE

REMOVE WOOD TRIM AROUND CEILING PERIMETER, TYP

1. CONTRACTOR TO COORDINATE ALL REMOVAL WITH THE REQUIREMENTS OF NEW CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF ALL ITEMS ASSOCIATED WITHIN THE DEMOLISHED AREA.

2. REFERENCE MECH., AND ELEC., DEMO DRAWINGS FOR ASSOCIATED DEMO SCOPE.

3. SCOPE OF WORK CONTAINS SUSPECT LOCATIONS OF HAZARDOUS BUILDING MATERIALS. ABATEMENT IN LOCATIONS CONTAINING HAZARDOUS BUILDING MATERIALS IS REQUIRED. CONTRACTOR TO COMPLY WITH PROPER REMOVAL/MITIGRATION PROCEDURES AS REQUIRED.

GENERAL NOTES - DEMO PLANS

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:15

PM

FIRST FLOORDEMOLITION REFLECTEDCEILING PLAN

AD-801V.WIEGANDK.KORABV.WIEGAND

18-1006

1/4" = 1'-0"1 FIRST FLOOR DEMOLITION REFLECTED CEILING PLANN

SCALE: 1/4" = 1'-0"

08' 4' 2'

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

Page 7: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

STAIR 1E

MECHANCIALE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

REMOVE EXISTING GYP BD SOFFIT TO BE REPLACED FOLLOWING VENTILATION WORK. FRAMING TO REMAIN

STORAGEE

REMOVE GYP. BD. CEILING TO BE REPLACED. REMOVE ALL EXISTING DEVICES AND LIGHTING FIXTURES TO BE SALVAGED FOR REINSTALLATION.

STAIR 1E

MECHANCIALE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

STORAGEE

INSTALL NEW GYP BD ON EXISTING FRAMING, PAINT TO MATCH EXISTING

INSTALL NEW GYB BD CEILING ON EXISTING FRAMING. PAINT TO MATCH EXISTING. REINSTALL SALVAGED DEVICES AND LIGHTING FIXTURES IN ORIGINAL LOCATIONS.

1. CONTRACTOR TO COORDINATE ALL REMOVAL WITH THE REQUIREMENTS OF NEW CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF ALL ITEMS ASSOCIATED WITHIN THE DEMOLISHED AREA.

2. REFERENCE MECH., AND ELEC., DEMO DRAWINGS FOR ASSOCIATED DEMO SCOPE.

3. SCOPE OF WORK CONTAINS SUSPECT LOCATIONS OF HAZARDOUS BUILDING MATERIALS. ABATEMENT IN LOCATIONS CONTAINING HAZARDOUS BUILDING MATERIALS IS REQUIRED. CONTRACTOR TO COMPLY WITH PROPER REMOVAL/MITIGRATION PROCEDURES AS REQUIRED.

GENERAL NOTES - DEMO PLANS

1. MATERIAL FINISH LEGEND, SEE SHEET A-701.2. LIGHTING FIXTURES; REF ELECTRICAL DWGS.3. ALL CEILING FIXTURES AND DEVICES TO BE

CENTERED IN CEILING AND/OR ALIGNED WITH ARCHITECTURAL ELEMENTS UNLESS NOTED OTHERWISE.

4. REFERENCE ELEC DWGS FOR ADDITIONAL LIGHT FIXTURE INFO.

5. ANY CEILING MOUNTED LIGHTING OR DEVICES MAY BE SUSPENDED FROM WOOD DECK BUT FASTENERS SHALL NOT PENETRATE FULLY THROUGH THE DECK.

RCP NOTES

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:00

PM

LOWER LEVELDEMOLITION PLAN ANDNEW FLOOR PLAN

A-101V.WIEGANDK.KORABV.WIEGAND

18-1006

No. Description Date1 ISSUED FOR 100% DESIGN 09/17/2018

1/8" = 1'-0"1LOWER LEVELDEMOLITION FLOOR PLAN

1/8" = 1'-0"2LOWER LEVELFLOOR PLAN

SCALE: 1/8" = 1'-0"

016' 8' 4'

Page 8: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

1. PARTITION TYPES, SEE SHEET A-301.2. FINISH FLOOR PLAN, SEE SHEET A-701.3. FURNITURE PLAN, SEE SHEET A-702.

FLOOR PLAN NOTES

DN127 SF

102

1074 SF

OFFICE101

ENTRY100

BREAK OUTSPACE

1A-301

2A-301

P1A-301

N.I.C.

A-9002

OFFICEE

BOOKKEEPINGE

OFFICEE

LOCKERSE

RoomE

STAIR #1E

MEN'SE

WOMEN'SE

BREAK ROOME

NEW WINDOW WITH INTERIOR WOOD CASING, WS-1 TYP

NEW WINDOW WITH INTERIOR WOOD CASING, WS-1 TYP

INFILL EXISTING OPENING WITH 8" (2HR) UL DESIGN NUMBER U905 TO MATCH ADJACENT

INFILL EXISTING OPENING WITH 8" CMU (1HR) UL DESIGN U905 TO MATCH ADJACENT.

INSTALL NEW WALL TO WALL CARPET TILE; REFER TO FINISH FLOOR PLANINFILL EXISTING OPENING 8"

CMU (1HR), UL DESIGNED U905 TO MATCH ADJACENT.

INSTALL NEW WALL TO WALL CARPET TILE; REFER TO FINISH FLOOR PLAN

P1P1

P1

P1

P1

P1

P1

NEW SUPPLY GRILLE, TYP. REFER TO MECH DWGS. INSTALL MINERAL WOOL AND SEALANT IN ALL GAPS BETWEEN CONCRETE DECK AND DUCT, TYP.

TYP OF 4

P1P1

C.J. C.J.

C.J. C.J.

100

1A-900

ALIGN CONTROL JOINT WITH EDGE OF WINDOW

ALIGN CONTROL JOINT WITH EDGE OF WINDOW

ALIGN CONTROL JOINT WITH EDGE OF DOOR FRAME

ALIG

N

TYP ENTIRE ROOM

TYP ENTIRE ROOM

TYPENTIREROOM

M.O.

4' - 0"

M.O.

4' - 0"

ALIGN WITH EDGE OF BEAM

ALIGN WITH EDGE OF BEAM

CL CL CL CL

CL

INSTALL FIRE EXTINGUISHER AND WALL MOUNTING BRACKET

A-9022

A-9025

TYP OF 4

REINSTALL VERTICAL BLINDS, TYP OF 4

INSTALL NEW VERTICAL BLINDS TO MATCH EXISTING, TYP OF 2

FE

2A-301

A-9022

INSTALL REROUTED DOWNSPOUT WITH MATCHING MATERIAL, GUAGE AND COLOR.

INSTALL REROUTED DOWNSPOUT WITH

MATCHING MATERIAL, GAUGE AND COLOR.

A-9028

PATCH EXISTING FLOOR OPENINGS; REF TO DETAIL 2/A-201

PROVIDE NEW WOOD CASING WITH JAMB EXTENSIONS STAINED TO MATCH EXISTING, TYP OF 4

M.O.

4' - 0"

INFILLED CONCRETE IN OPENING

DOWELS AS REQUIRED, TYP

EXISTING FLOOR SLAB

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:01

PM

FIRST FLOOR PLAN

A-201V.WIEGANDK.KORABV.WIEGAND

18-1006

N

SCALE: 1/4" = 1'-0"

08' 4' 2' 1/4" = 1'-0"1 FIRST FLOOR PLAN

No. Description Date1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/20183 ISSUED FOR 100% DESIGN 09/17/2018

6" = 1'-0"2DETAIL ATFLOOR INFILL

Page 9: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

EXISTING MASONRY PARTITION BEYOND

EXISTING PARTITION

EXISTING WINDOW

EXISTING BEAM BEYOND

EXISTING BUILT-UP ROOF WITH GRAVEL OVER TWO LAYERS RIGID INSULATION (1-1/2" OVER 1") OVER 3" NOMINAL TIMBER DECK, TYP

NEW FRAMING AND GYPSUM BOARD OVER EXISTING PARTITION; ALIGN FACE TO ADJACENT PARTITION

EXISTING FOUNDATION

SCHEDULED BASE, RB-1, TYP

NEW FRAMING AND GYPSUM BOARD OVER EXISTING PARTITION; ALIGN FACE TO ADJACENT PARTITION

EXISTING CONCRETE SLAB ON METAL DECK OVER STEEL JOISTS

A-9024

A-9026

NEW INTERIOR WOOD CASING WITH JAMB EXTENSION TO MATCH EXISTING FINISH

NEW INTERIOR WOOD TRIM AT CEILING AND BEAM PERIMETER

T/ FINISH FLOOR0"

B/O LAM. WOOD BEAM9'-2 1/2"

B/O FINISH CEILING10'-5"

EXISTING MASONRY WALL PARTITION

PARTITION P1, NEW FRAMING AND GYPSUM BOARD OVER EXISTING PARTITION, TYP

NEW FIXED WINDOW WITH INTERIOR STAINED WS-1 TO MATCH EXISTING WITH INSULATED GLAZING

EXISTING BEAM BEYOND

EXISTING BUILT-UP ROOF WITH GRAVEL OVER TWO LAYERS RIGID INSULATION (1-1/2" OVER 1") OVER 3" NOMINAL TIMBER DECK, TYPA-902

1

A-9023

EXISTING FOUNDATION

SCHEDULED BASE, RB-1, TYP

P1

EXISTING CONCRETE SLAB ON METAL DECK OVER STEEL JOISTS

NEW LIMESTONE SILL

FINISH FLOOR

5/8" GYPSUM BOARD

1-1/2" FURRING FASTENED TO EXISTING MASONRY PARTITION

EXISTING BACKUP PARTITION

FINISH CEILING

PLA

N

5/8" GYPSUM BOARD

1-1/2" FURRING FASTENED TO EXISTING MASONRY PARTITION

EXISTING BACKUP PARTITION

5/8" GYPSUM BOARD

1-1/2" FURRING @ 16" O.C. FASTENED TO EXISTING MASONRY PARTITION

EXISTING BACKUP PARTITION

SCHEDULED BASE, RB-1

INTERIOR TRIM AT PERIMETER

T/ FINISH FLOOR0"

1A-301

2A-301

B/O FINISH CEILING10'-5"

EXISTING ROOF FASCIAEXISTING EXPOSED BEAM STRUCTURE

EXISTING WINDOWS, TYP OF 5

NEW WINDOW WITH LIMESTONE SILL

NEW WINDOW WITH LIMESTONE SILL

EXISTING MASONRY WALL CONSTRUCTION

INSTALL REROUTED DOWNSPOUT WITH MATCHING MATERIAL, GUAGE AND COLOR. PATCH GUTTER AT RELOCATED DOWNSPOUT WITH MATCHING MATERIAL, GAUGE AND COLOR, AND PROVIDE WATERTIGHT SEAL.

OUTLINE OF EXISTING MECHANICAL EQUIPMENT

TYP M.O.

4' - 0"

TYP

M.O

.

5' -

0"

EXISTING GRADEEXISTING BOOT

CUT CASING TRIM AT WINDOW M.O.; PAINT CUT END PT-1

EXISTING LIGHT FIXTURE TO REMAIN

EXISTING TRIM, TYP

EXISTING STONE BASE, TYP

CUT TRIM AT WINDOW M.O.; PAINT CUT END PT-1

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:04

PM

BUILDING ELEVATIONS,PARTITION TYPES, ANDWALL SECTIONS

A-301V.WIEGANDK.KORABV.WIEGAND

18-1006 1" = 1'-0"1WALL SECTIONTYPICAL EXISTING WINDOW

1" = 1'-0"2WALL SECTIONTYPICAL NEW WINDOW

1" = 1'-0"P1 PARTITON TYPE 1

1/4" = 1'-0"7 NORTH ELEVATION

SCALE: 1/4" = 1'-0"

08' 4' 2'

SCALE: " = 1'-0"

04' 2' 1'

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

Page 10: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

DN

102

OFFICE101

ENTRY100

BREAK OUTSPACE

N.I.C.

RB-1 AT PERIMETER, TYP ALL WALLS

RB-1 AT PERIMETER, TYP ALL WALLS

FLOOR SUPPLY GRILLE, TYP. REF MECHANICAL DWGS

OFFICEE

STAIR #1E

OFFICEE

LOCKERSE

BOOKKEEPINGE

OFFICEE

BREAK ROOME

WOMEN'SE

MEN'SE

ALIGN TO THRESHOLD

ALIGN TO EXISTING THRESHOLD

PAINT PT-2

PAINT PT-1; RB-1

PAINT PT-1, TYP ALL WALLS

PAINT PT-1, TYP ALL WALLS

PA

INT

PT-

1;

RB

-1

EXTERIOR/INTERIOR WALL FINISHES

ABBREV DESCRIPTION

MATERIAL FINISH LEGEND

CEILING FINISHES

FLOOR FINISHES

CARPET TILE BASIS OF DESIGN: INTERFACE, NET EFFECT COLLECTION B701, 25CM X 1M, COLOR 102893 CASPIAN

CPT-1

RESILIENT BASE MATCH EXISTINGRB-1

GYPSUM BOARDGWB-1

GYPSUM WALL BOARD BASIS OF DESIGN (SEE SPECIFICATIONS)

GWB-1

PAINT COLOR: SW 7035 AESTHETIC WHITE

PT - 1

PAINT COLOR: SW 6991 BLACK MAGIC

PT - 2

DESCRIPTION

WOOD STAIN MATCH EXISTING WINDOWS

WS-1

WOOD STAIN MATCH EXISTING BEAMS, AND TONGUE AND GROOVE

WS-2

BASIS OF DESIGN (SEE SPECIFICATIONS)

SUPPLY GRILLE, REF MECH DWGS

SEALANT, TYP

MINERAL WOOL TO FILL GAP BETWEEN EXISTING FLOOR SLAB AND NEW FLOOR VENT.

EXISTING FLOOR SLAB

FINISH FLOOR

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:04

PM

FIRST FLOOR FINISHPLAN

A-701V.WIEGANDK.KORABV.WIEGAND

18-1006

1/4" = 1'-0"1 FIRST FLOOR FINISH PLAN

SCALE: 1/4" = 1'-0"

08' 4' 2'

N

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

6" = 1'-0"2DETAIL ATFLOOR REGISTER

6" 4" 2"

SCALE: 6" = 1'-0"

0

Page 11: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

OFFICE101

102

N.I.C.

BREAK OUT SPACE

ENTRY100

LATERAL FILE DRAWERS

LATERAL FILE DRAWERS W/ PLAM COUNTERTOP, TYP

LATERAL FILE DRAWERS WITH PLAM COUNTERTOP

LATERAL FILE DRAWERS

3' - 8" 3' - 3"

LATERAL FILE DRAWERS

LATERAL FILE DRAWERS

3' - 3" 3' - 4"

3' - 3" 3' - 3" 3' - 1"

EXISTING DRAWING TABLE

EXISTING DRAWING TABLE; GC TO MOVE FROM BASEMENT, TYP OF 3

EXISTING DRAWING TABLE

MANAGER WORKSTATION

15' - 6"

TYPICAL WORKSTATION

12' - 3"

TYPICAL WORKSTATION

9' - 3"

TYPICAL WORKSTATION

9' - 3"

MANAGER WORKSTATION

10' - 10"

3' - 3"

1' - 7 1/4"

MANAGER WORKSTATION

15' - 6"

TYPICAL WORKSTATION

12' - 3"

TYPICAL WORKSTATION

9' - 1"

TYPICAL WORKSTATION

9' - 3"

TYPICAL WORKSTATION

9' - 0 1/2"

TYPICAL WORKSTATION

10' - 10"

3' - 0 1/2" 3' - 4"3' - 8" PLAM COUNTERTOP ON STATIONARY LEGS

UNDER COUNTER REFRIGERATOR, N.I.C.

NEW OFFICE CHAIR, TYP

SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703

SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703 SEE TYPICAL ON A-703SEE TYPICAL ON A-703

9' -

0" T

YP9'

- 0"

TYP

4' -

11 1

/2"

NEW CONFERENCE TABLE WITH 4 CHAIRS

OFFICEE

RoomE

LOCKERSE

OFFICEE

BOOKKEEPINGE

OFFICEE

BREAK ROOME

WOMEN'SE

MEN'SE

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:06

PM

FIRST FLOORFURNITURE PLAN

A-702V.WIEGANDK.KORABV.WIEGAND

18-1006

1/4" = 1'-0"1FIRST FLOORFURNITURE PLAN

SCALE: 1/4" = 1'-0"

08' 4' 2'

N

No. Description Date1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/20183 ISSUED FOR 100% DESIGN 09/17/2018

Page 12: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:08

PM

FURNITURE TYPICALWORKSTATIONS

A-703V.WIEGANDK.KORABV.WIEGAND

18-1006

No. Description Date1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

BASIS OF DESIGN: HERMAN MILLER CANVAS COLLECTION

BASIS OF DESIGN: HERMAN MILLER CANVAS COLLECTION

11" FROSTED GLASS

11" FROSTED GLASS

Page 13: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

F

F

F

OS

S S S S S S S

AP

AP

S

OS

NEW GYP. BD. CEILING ON METAL FRAMING, PAINTED PT-1

INSTALL RECESSED LIGHT FIXTURES; REFER TO ELECTRICAL DWGS

LINE OF ROOF ABOVE

N.I.C.

INSTALL SUSPENDED LIGHT FIXTURES AT 8'-8" AFF HUNG FROM DECK; REFER TO ELECTRICAL DWGS

10' - 5"

8' - 8"

V.I.F.

CEILING TO REMAIN

EXISTING BEAMS, AND TONGUE AND GROOVE

CEILING STAINED TO MATCH ADJACENT

EXISTING BEAMS, AND TONGUE AND GROOVE

PATCH GUTTER AT RELOCATED DOWNSPOUTS WITH MATCHING MATERIAL, GAUGE AND COLOR, AND PROVIDE A WATERTIGHT SEAL

FIXTURE LENGTH

4' - 0" TYP

EQ12

' - 4

1/2

"EQ

EQ EQ

N.I.C.

RETURN GRILLE, REF MECH DWGS

EXISTING WALL GRILLE, REF MECH DWGS RETURN GRILLE,

REF MECH DWGS

RELOCATED DOWNSPOUTS, REF SHEET A-301 FOR ELEVATIONS

REINSTALL SALVAGED ACCESS PANEL, PAINT PT-1

REINSTALL SALVAGED ACCESS PANEL, PAINT PT-1

1. MATERIAL FINISH LEGEND, SEE SHEET A-701.2. LIGHTING FIXTURES; REF ELECTRICAL DWGS.3. ALL CEILING FIXTURES AND DEVICES TO BE

CENTERED IN CEILING AND/OR ALIGNED WITH ARCHITECTURAL ELEMENTS UNLESS NOTED OTHERWISE.

4. REFERENCE ELEC DWGS FOR ADDITIONAL LIGHT FIXTURE INFO.

5. ANY CEILING MOUNTED LIGHTING OR DEVICES MAY BE SUSPENDED FROM WOOD DECK BUT FASTENERS SHALL NOT PENETRATE FULLY THROUGH THE DECK.

RCP NOTES

RCP LEGEND

OCCUPANCY SENSOR; REF ELEC DWGS

EXIT SIGN (WALL MTD); REF ELEC DWGS

SMOKE DETECTOR; REF ELEC DWGS

2x4 LAY-IN LIGHT FIXTURE; REF ELEC DWGS

PENDANT LIGHT FIXTURE; REF ELEC DWGS

FFIRE ALARM HORN/STROBE; REF ELEC DWGS

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:09

PM

FIRST FLOORREFLECTED CEILINGPLAN

A-801V.WIEGANDK.KORABV.WIEGAND

18-1006

1/4" = 1'-0"1FIRST FLOORREFLECTED CEILING PLAN N

SCALE: 1/4" = 1'-0"

08' 4' 2'

No. Description Date1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/20183 ISSUED FOR 100% DESIGN 09/17/2018

Page 14: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

T/ FINISH FLOOR0"

1A-301

2A-301

P1A-301

B/O LAM. WOOD BEAM9'-2 1/2"

B/O FINISH CEILING10'-5"

NEW WINDOW WITH INTERIOR WOOD CASING, WS-1, TYP. PROVIDE NEW VERTICAL BLINDS TO MATCH EXISTING

NEW INTERIOR WOOD CASING, WS-1. REINSTALL VERTICAL BLINDS, TYP OF 4

RB-1, TYP ALL WALLS

PT-1, TYP ALL WALLS

TYPICAL FURNITURE, REFER TO FURNITURE PLAN ON SHEET A-702 AND A-703.

INTERIOR WOOD TRIM AT CEILING PERIMETER TO MATCH ORIGINAL, WS-1, TYP

NEW WINDOW WITH INTERIOR WOOD CASING, WS-1, TYP. PROVIDE NEW VERTICAL BLINDS TO MATCH EXISTING

T/ FINISH FLOOR0"

7' -

4"

3' - 0" DOORB/O DROP CEILING

8'-8"

7' -

2" D

OO

R

PARTITION P1: NEW FRAMING AND GYP BOARD OVER EXISTING MASONRY CONSTRUCTION, PT-1

RB-1, TYP WALL WALLS

9A-902

10A-902

11A-902

7A-902

NEW STOREFRONT ENTRY WITH TEMPERED GLAZING

PANIC BAR ON PUSH SIDE OF DOOR

DOOR CLOSER

A-902 A-902

A-902

1415

13

M.O.

4' - 0"

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:10

PM

INTERIOR ELEVATIONS

A-900V.WIEGANDK.KORABV.WIEGAND

18-1006

1/4" = 1'-0"1OFFICEINTERIOR ELEVATION

1/2" = 1'-0"2BREAK-OUT SPACEINTERIOR ELEVATION No. Description Date

1 ISSUED FOR 30% DESIGN 07/23/20182 ISSUED FOR 100% DESIGN 09/17/2018

SCALE: 1/2" = 1'-0"

04' 2' 1'

SCALE: 1/4" = 1'-0"

08' 4' 2'

Page 15: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

NEW INTERIOR WOOD JAMB EXTENSION, WS-1, TYP

NEW WINDOW WITH INSULATED GLAZING

EXISTING BUILT-UP ROOF WITH GRAVEL OVER TWO LAYERS RIGID INSULATION (1-1/2" OVER 1") OVER 3" NOMINAL WOOD DECK

EXISTING MASONRY WALL PARTITION

NEW FRAMING AND GYPSUM BOARD OVER EXISTING PARTITION

NEW ALUM CLAD WOOD WINDOW

NEW INTERIOR WOOD CASING, WS-1, TYP

LIMESTONE SILL

S.S. DRIP

WOOD BLOCKING

EXISTING MASONRY WALL PARTITION BEYOND

EXISTING WINDOW TO REMAIN

EXISTING WALL PARTITION

NEW FRAMING AND GYPSUM BOARD OVER EXISTING WALL PARTITION

NEW INTERIOR WOOD CASING AND JAMB EXTENSION, WS-1, TYP

EXISTING WINDOW TO REMAIN

NEW INTERIOR WOOD CASING AND JAMB EXTENSION, WS-1, TYP

EXISTING WALL PARTITION

NEW FRAMING AND GYPSUM BOARD OVER EXISTING WALL PARTITION

EXISTING WALL PARTITION

NEW FRAMING AND GYPSUM BOARD OVER EXISTING WALL PARTITION

NEW INTERIOR WOOD CASING AND JAMB EXTENSION, WS-1, TYP

EXISTING WINDOW TO REMAIN

EXISTING WALL PARTITION

NEW FRAMING AND GYPSUM BOARD OVER EXISTING WALL PARTITIONNEW INTERIOR WOOD CASING, WS-1, TYP

NEW ALUM CLAD WOOD WINDOW, GL-1

WOOD BLOCKING

INTERIOR WOOD JAMB EXTENSION,WS-1, TYP

ALUMINUM STOREFRONT FRAMING BEYOND

SEALANT AND BACKER ROD, TYP

GYPSUM BOARD ON METAL FRAMING UP TO DECK, PAINTED PT-1

GYP BD BEYOND MEDIUM STILE ALUMINUM STOREFRONT ENTRY DOOR

STOREFRONT FRAMING, TYP

JOINT SEALANT AND BACKER ROD, TYP.

GYPSUM BD OVER METAL FRAMING, PAINTED PT-1, TYP

JOINT SEALANT AND BACKER ROD, TYP

ALUMINUM STOREFRONT

GYPSUM BD, PT-1, TYP

FINISH FLOOR

BASE AS SCHEDULED, RB-1

EXISTING CMU PARTITION, PTD TO MATCH EXISTING

ALUMINUM STOREFRONT FRAMINGMEDIUM STILE STOREFRONT ENTRY DOOR

JOINT SEALANT AND BACKER ROD, TYP

TYP

1 3/4"

PARTITION P1: GYMSUM BD OVER METAL FRAMING OVER EXISTING PARTITION

ALUMINUM STOREFRONT FRAMING

MEDIUM STILE STOREFRONT ENTRY DOOR

TYP

1 3/4"

4"

EXISTING CMU PARTITION, PTD TO MATCH EXISTING

ALUMINUM STOREFRONT FRAMING

SEALANT AND BACKER ROD, TYP

GYPSUM BD, PT-1

TYP

1 3/4"

10"

MEDIUM STILE ALUMINUM STOREFRONT ENTRY DOOR

FINISH FLOOR

EXISTING DOOR, PAINTED PT-2

EXISTING MASONRY PARTITION

METAL FRAMING WITH GYP BD, PAINTED PT-1

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

EN

OV

ATI

ON

41W

011

BU

RLI

NG

TON

RO

AD

CA

MP

TON

HIL

LS, I

L 60

175

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

C:\U

sers

\vw

iega

nd\D

ocum

ents

\KD

OT

Offi

ce R

enov

ati o

n_vw

iega

nd.rv

t9/

27/2

018

4:52

:13

PM

WINDOW AND DOORDETAILS

A-902V.WIEGANDK.KORABV.WIEGAND

18-1006

3" = 1'-0"1NEW WINDOWHEAD DETAIL

3" = 1'-0"3NEW WINDOWSILL DETIAL

3" = 1'-0"4EXISTING WINDOWHEAD DETAIL

3" = 1'-0"6EXISTING WINDOWSILL DETAIL

3" = 1'-0"5EXISTING WINDOWJAMB DETAIL

3" = 1'-0"2NEW WINDOWJAMB DETAIL

12" 8" 4"

SCALE: 3" = 1'-0"

0

3" = 1'-0"9STOREFRONTHEAD DETAIL 3" = 1'-0"10 Section 6

3" = 1'-0"11STOREFRONTSILL DETAIL

3" = 1'-0"13STOREFRONTJAMB DETAIL

3" = 1'-0"14STOREFRONT CENTERJAMB DETAIL

3" = 1'-0"15STOREFRONT DOORJAMB DETAIL

No. Description Date1 ISSUED FOR 100% DESIGN 09/17/2018

3" = 1'-0"7STOREFRONT DOORSILL DETAIL

3" = 1'-0"8EXISTING DOORJAMB DETAIL

Page 16: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

3

3

3

3

OFFICE EXISTING FILEVAULT

STAIR #1ENTRY

1. SEE SHEET E200 FOR THE NEW LIGHTING PLAN.

1. REMOVE AND DISPOSE OF EXISTING PENDANT HUNG FLUORESCENT LIGHT FIXTURES, LAMPS, STRUT SUPPORTS, CONDUITS AND CONDUCTORS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DISPOSAL AND RECYCLING COSTS. REMOVE EXISTING LIGHTING CONDUCTORS. EXISTING CONCEALED CONDUITS SHALL BE ABANDONED IN PLACE. EXISTING CEILING JUNCTION BOXES MAY BE REUSED FOR SUPPORT POINTS ONLY. PROVIDE CANOPY COVERS, ARLINGTON #CP3540 OR EQUAL, AT ABANDONED JUNCTION BOXES.

2. REMOVE AND DISPOSE OF EXISTING LIGHT SWITCHES, BOXES, CONDUITS AND WIRING. CONCEALED CONDUITS SHALL BE ABANDONED IN PLACE.

3. REMOVE AND DISPOSE OF EXISTING EXIT FIXTURES.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:1

6 PM

FIRST FLOOR LIGHTINGDEMOLITION

E100PLZNTPPLZ

M1600010

0 1' 2' 4' 8'

FIRST FLOOR LIGHTING DEMOLITION1

GENERAL NOTES

KEYNOTES (THIS SHEET)

1

2

2

2

33

2

1TYP. TYP.

OFFICE

No. Description Date

Page 17: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

D D D D

LUMINAIRETYPE

A

B

X

ABBREVIATIONS:

NOTES:1.

MANUFACTURERFINELITE

FINELITE

SURELITES

REFER TO LIGHTING PLAN FOR MOUNTING HEIGHT.

CATALOG NUMBERFP-2ID-64'-S-H-835-TG-F-96LG-120V-DC-FA-FE-C4

HPR-LED-F-2X4-DCO-S-835-120V-SC-C1

APX7R

F - FLUORESCENTI - INCANDESCENTH - HIGH INTENSITY DISCHARGEEOL - END OF LIFE PROTECTION

PS - PULSE START

LAMPSTYPE

LED

LED

LED

CATALOG #

NA

NA

NA

E - ELECTRONIC HIGH FREQUENCYS - STANDARD ENERGY-SAVING MAGNETICO - OTHER (SEE NOTES)SCWA - SUPER CONSTANT WATTAGE AUTO TRANSFORMER

L - LED

LIGHTING FIXTURE SCHEDULENO.

-

-

-

WATTS/LAMP

27 WATTS

27 WATTS

.99 WATTS

BALLASTSTYPE

DIMMING DRIVER

DIMMING DRIVER

STANDARD DRIVER

NO.

-

-

-

VOLT

120V

120V

120V

MOUNT

RECESSED

RECESSED

WALL

DESCRIPTION2" APERTURE DIRECT/INDIRECT LINEAR PENDANT FIXTURELEDSEPARATE DIMMABLE CONTROL FOR DOWNLIGHT AND UPLIGHT2'X4' RECESSED GRID CEILINGLED HIGH PERFORMANCE FLAT LENSDIMMABLEWHITE PLASTIC EXIT SIGN WITH RED LETTERSLED

WU - WITH UNITEX - EXISTINGNA - NOT AVAILABLEEP - ELECTRONIC PROGRAMMED RAPID START

UNV - UNIVERSAL VOLTAGE 120/277

NOTES1

OS

OFFICE

STAIR #1ENTRY

1. SEE SHEET E100 FOR THE EXISTING LIGHTNG DEMOLITION PLAN.

2. ALL SURFACE RACEWAY SHALL BE IVORY WIREMOLD 500 OR EQUAL.

1. PROVIDE NEW CABLE HUNG LIGHT FIXTURES. MOUNT FIXTURES 8'-8" ABOVE FINISHED FLOOR TO BOTTOM OF FIXTURE. SEE FIXTURE SCHEDULE. PROVIDE NEW FEED POINTS AT THE PLAN EAST END OF EACH RUN. PROVIDE NEW CONDUIT AND WIRE TO THE NEW SWITCHES INDICATED BELOW. ALL POWER AND CONTROL CABLING SHALL BE INSTALLED IN CONDUIT. NO FREE AIR CABLING SHALL BE ALLOWED. CONCEAL AS MUCH CONDUIT AS POSSIBLE IN THE NEW 1-1/2" STUD WALLS. PROVIDE SURFACE RACEWAY ROUTED ALONG THE EXPOSED BEAMS FROM THE PLAN SOUTH WALL TO THE FIXTURE FEED POINTS. NEW SURFACE RACEWAY AT THE BEAM SHALL BE MOUNTED MINIMUM 1-1/2" BELOW THE CEILING DECK IN ACCORDANCE WITH NEC 300.4(E). PROVIDE JUNCTION BOX WITH FLEXIBLE WHIP TO FIXTURE AT BEAM.

2. PROVIDE NEW COMBINATION SWITCH/DIMMERS FOR CONTROL OF NEW LIGHTING AS FOLLOWS:A. (2) LUTRON #DVSTV-WH OR EQUAL SINGLE POLE SWITCH WITH 0-10V SLIDE DIMMER NEAR DOOR FOR CONTROL OF THE FIRST ROW OF LIGHT FIXTURES INSIDE THE DOOR.B. (2) LUTRON #DVSTV-WH OR EQUAL SINGLE POLE SWITCH WITH 0-10V SLIDE DIMMER ADJACENT TO PART A DIMMER FOR CONTROL OF THE ROW OF LIGHT FIXTURES CLOSEST TO THE

WINDOW.3. PROVIDE NEW RECESSED LIGHT FIXTURES. SEE FIXTURE SCHEDULE.

4. PROVIDE NEW EXIT FIXTURE. SEE FIXTURE SCHEDULE.

5. PROVIDE NEW WALL MOUNT OCCUPANCY SENSOR WITH DIMMER, LUTRON #MS-Z101-V-WH OR EQUAL.

6. BATTERY BACKED UP SECTION OF LIGHT FIXTURE. PROVIDE WIRING PER MANUFACTURERS INSTRUCTIONS.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:1

8 PM

FIRST FLOOR LIGHTINGPLANS

E200PLZNTPPLZ

M1600010

0 1' 2' 4' 8'

FIRST FLOOR LIGHTING NEW WORK1

GENERAL NOTES KEYNOTES (THIS SHEET)

1

2

3

5

OFFICE

1 4

A

A

B B

X

6

6

No. Description Date

Page 18: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

H

H

DH

OFFICE EXISTING FILEVAULT

STAIR #1ENTRY

J J

JJJJ

1. SEE SHEET E-401 FOR FIRST FLOOR POWER AND SYSTEMS NEW WORK PLAN.

1. REMOVE EXISTING RECEPTACLE RECESSED IN BLOCK WALL AND WIRING AS FOLLOWS:

A. REMOVE WIRE BACK TO SOURCE IF ALL RECEPTACLES ON THE CIRCUIT ARE REMOVED. REMOVE ASSOCIATED CONDUIT AND BOXES.

B. REMOVE WIRE BACK TO NEAREST JUNCTION BOX IF CIRCUIT SERVES RECEPTACLES TO REMAIN. REMOVE ASSOCIATED CONDUIT AND BOXES.

C. IN THE EVENT THAT THE CIRCUIT EXTENDS TO OTHER RECEPTACLES THROUGH THE RECEPTACLE JUNCTION BOX, PROVIDE SPLICES AS REQUIRED TO MAINTAIN EXISTING TO REMAIN RECEPTACLES. PROVIDE BLANK COVER AT BOX TO REMAIN.

2. EXISTING RECEPTACLE SERVING BUILDING AUDIO SYSTEM. AUDIO SYSTEM AND SHELF TO REMAIN. REMOVE EXISTING SURFACE MOUNT RECEPTACLE. REMOVE EXISTING SURFACE MOUNT RACEWAY CONTAINING SPEAKER WIRING. PROTECT SPEAKER WIRING DURING CONSTRUCTION. REMOVE SHELF AND PROTECT FOR REUSE. AUDIO SYSTEM SHALL REMAIN IN SERVICE DURING CONSTRUCTION. PROVIDE TEMPORARY POWER AND TEMPORARY SUPPORTS AS REQUIRED TO MAINTAIN SYSTEM DURING CONSTRUCTION. PROVIDE PLASTIC SHEETING TO PROTECT EQUIPMENT FROM CONSTRUCTION DUST. PLASTIC SHEETING SHALL BE INSTALLED IN A MANNER THAT ALLOWS VENTILATION FOR EQUIPMENT. SEE SHEET E401 FOR ADDITIONAL INFORMATION.

3. DISCONNECT EXISTING SMOKE DETECTOR. PROTECT AND STORE DETECTOR FOR REUSE. PROTECT EXISTING WIRING AND SURFACE MOUNT RACEWAY. PROVIDE CONNECTIONS TO MAINTAIN SYSTEM FUNCTIONALITY DURING CONSTRUCTION.

4. DISCONNECT EXISTING SMOKE DETECTOR. REMOVE EXISTING WIRING AND SURFACE MOUNT RACEWAY TO ACCOMODATE CEILING REMOVAL. PROVIDE CONNECTIONS AND WIRING TO MAINTAIN SYSTEM FUNCTIONALITY DURING CONSTRUCTION.

5. DISCONNECT EXISTING FIRE ALARM HORN. PROTECT AND STORE DEVICE FOR REUSE. REMOVE EXISTING WIRING AND SURFACE MOUNT RACEWAY. PROVIDE CONNECTIONS TO MAINTAIN SYSTEM FUNCTIONALITY DURING CONSTRUCTION.

6. REMOVE EXISTING FLOOR MOUNTED MAGNETIC DOOR HOLD, CONDUIT AND WIRE BACK TO SOURCE.

7. REMOVE EXISTING FLEXIBLE WHIP SERVING FURNITURE WALLS THROUGH THE FLOOR BACK TO JUNCTION BOX BELOW. CAP CIRCUITS AT JUNCTION BOX. MARK JUNCTION BOX WITH CIRCUIT NUMBER.

8. REMOVE EXISTING SURFACE MOUNT DATA BOX AND CONDUIT FED THROUGH THE FLOOR. PULL EXISTING DATA CABLES BACK BELOW FLOOR, COIL AND SUPPORT AT THE CEILING BELOW. MARK CABLES WITH ANY IDENTIFIERS SHOWN ON DATA PLATE.

9. REMOVE EXISTING RECEPTACLE AND RACEWAY TO ALLOW WALL REMOVAL. PROVIDE CONDUIT, CONDUCTORS, JUNCTION BOXES AND SPLICES AS REQUIRED TO MAINTAIN CIRCUIT IF NECESSARY.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:1

9 PM

FIRST FLOOR POWERAND SYSTEMSDEMOLITION

E300PLZNTPPLZ

M16000100 1' 2' 4' 8'

FIRST FLOOR POWER AND SYSTEMS DEMOLITION1

GENERAL NOTES

KEYNOTES (THIS SHEET)

3

5

6

OFFICE

2

34

1 1 1

1

1

1

1

7 7 7 7

7 7

8 8 8

8 8 8

1

1

1

5

1

9

1

No. Description Date

Page 19: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

STORAGE

EQUIPMENTROOM

OFFICE AREA

MECHANICALROOM

STORAGE

SHOWERROOM

UNISEX

ELEVATOR

STORAGESTORAGESTORAGE

ENTRY(ABOVE) MECHANCIAL Room STORAGE

STORAGE

ELECTRICALROOM

1. EXISTING PANEL MDP.

2. EXISTING PANEL RPA.

3. EXISTING PANEL RPIG.

4. PROJECT AREA LOCATED ON FIRST FLOOR ABOVE THIS ROOM. STORAGE AREA HAS EXPOSED CEILING. ROUTE ALL NEW CONDUITS IN THIS EXPOSED CEILING AND UP THROUGH FLOOR TO LOCATIONS SHOWN.

1. SEE SHEET E-401 FOR FIRST FLOOR POWER AND SYSTEMS NEW WORK PLAN.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

0 PM

LOWER LEVELELECTRICAL POWERAND SYSTEMS

E400PLZNTPPLZ

M1600010

0 2' 4' 8' 16'

LOWER LEVEL POWER AND SYSTEMS NEW WORK1

KEYNOTES (THIS SHEET)

GENERAL NOTES

123

4

No. Description Date

vwiegand
Rectangle
vwiegand
Rectangle
vwiegand
Text Box
STORAGE
vwiegand
Text Box
STAIR #1
Page 20: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

H H

S

OFFICE

STAIR #1ENTRY

CONFERENCEROOM

J J J J J J

J J J J J

2 4 2 4 2 4

6 8 6 8 6

10

10 10 EX

12

12

12

12

1. SEE SHEET E-300 FOR FIRST FLOOR POWER AND SYSTEMS DEMOLITION PLAN.

2. CIRCUIT NUMBERS ARE SHOWN TO INDICATE NUMBER OF CIRCUITS REQUIRED. EXISTING CIRCUITS MADE AVAILABLE DURING THE DEMOLITION PHASE MAY BE REUSED, PROVIDE NEW CIRCUITS FROM THE ELECTRICAL ROOM SHOWN ON SHEET E-400 FOR ADDITIONAL REQUIRED CIRCUITS. RECORD ACTUAL CIRCUIT NUMBERS ON AS BUILT DRAWINGS. UPDATE PANELBOARD DIRECTORIES.

3. EXISTING FIRE ALARM SYSTEM IS A NOTIFIER FIRE ALARM SYSTEM SERVICED BY ALARM DETECTION SYSTEMS 630.844.6300. FIRE ALARM SYSTEM SHALL BE TESTED AND CERTIFIED BY A MANUFACTURERS REPRESENTATIVE. CERTIFICATION FEES SHALL BE INCLUDED IN THE BID FOR THIS WORK.

4. ALL SURFACE RACEWAY SHALL BE IVORY WIREMOLD 500 OR EQUAL.

5. ALL WALL MOUNTED DEVICES SHALL HAVE BOXES RECESSED IN THE FURRING WALL AND CONDUITS ROUTED DOWN THROUGH THE FLOOR TO THE EXPOSED CEILING BELOW.

1. PROVIDE NEW JUNCTION BOX WITH FLEXIBLE WHIP CONNECTION TO POWERED FURNITURE PANELS. COORDINATE ROUGH IN LOCATION WITH FURNITURE SHOP DRAWINGS. JUNCTION BOX SHALL BE INSTALLED IN NEW 1-1/2" FURRING WALL AND CONDUIT SHALL BE ROUTED THROUGH FLOOR TO THE CEILING SPACE BELOW.

2. PROVIDE NEW VOICE/DATA ROUGH IN CONSISTING OF 4" SQUARE BOX WITH 1" CONDUIT BEHIND FURRED WALLS STUBBED DOWN TO ACCESSIBLE CEILING SPACE BELOW. COORDINATE ROUGH IN LOCATION WITH FURNITURE SHOP DRAWINGS.

3. REINSTALL EXISTING SMOKE DETECTORS AND PROVIDE NEW SMOKE DETECTORS AS REQUIRED TO PROVIDE COVERAGE SHOWN. PROVIDE SURFACE RACEWAY AND WIRE AS REQUIRED TO EXTEND EXISTING WIRING TO NEW LOCATION. SURFACE RACEWAY SHALL BE ROUTED NORTH TO SOUTH ALONG THE SIDE OF THE BEAMS MINIMUM 1-1/2" BELOW DECK UNTIL TRANSITIONING TO EACH SMOKE DETECTOR. SMOKE DETECTORS SHALL BE MOUNTED TO THE BOTTOM OF THE DECK CENTERED IN THE BEAM CAVITY.

4. PROVIDE NEW FIRE ALARM HORN/STROBE. PROVIDE CONDUIT AND WIRE AS REQUIRED TO EXTEND EXISTING WIRING TO NEW LOCATION. CONDUIT AND WIRE SHALL BE ROUTED DOWN THROUGH THE FLOOR TO THE CEILING SPACE BELOW.

5. PROVIDE RECEPTACLE FOR BUILDING AUDIO EQUIPMENT. INSTALL OUTLET AT SAME HEIGHT AS EXISTING REMOVED OUTLET. REUSE EXISTING CIRCUIT. REINSTALL EXISTING SHELF AND EXISTING AUDIO EQUIPMENT REINSTALL EXISTING SURFACE RACEWAY TO CONCEAL EXISTING SPEAKER WIRING. RECONNECT EXISTING SPEAKER WIRING.

6. PROVIDE NEW FIRE ALARM STROBE. PROVIDE CONDUIT AND WIRE AS REQUIRED TO EXTEND WIRING TO NEW LOCATION.

7. PROVIDE NEW DUPLEX RECEPTACLE FOR MINI FRIDGE. COORDINATE LOCATION WITH OWNER.

8. PROVIDE NEW DUPLEX RECEPTACLE FOR COFFEE MACHINE. COORDINATE LOCATION WITH OWNER.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

1 PM

FIRST FLOOR POWERAND SYSTEMS NEWWORK

E401PLZNTPPLZ

M16000100 1' 2' 4' 8'

FIRST FLOOR POWER AND SYSTEMS NEW WORK1

GENERAL NOTES KEYNOTES (THIS SHEET)

2

1

34

OFFICE

TYP.

TYP.

TYP.TYP.

5

12

14

7

8No. Description Date

vwiegand
Rectangle
vwiegand
Rectangle
Page 21: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

1. DUCTWORK AND PIPING IS SHOWN IN SCHEMATIC FORM ONLY, OFFSETS AND CHANGES IN ELEVATION ARE NOT NECESSARILY SHOWN. ROUTE DUCTWORK AND PIPING IN AN ORDERLY MANNER AS REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS. COORDINATE LOCATION OF DUCTWORK AND PIPING WITH OTHER TRADES PRIOR TO INSTALLATION. WHERE POSSIBLE RACK PIPING HORIZONTALLY AND VERTICALLY.

2. COORDINATE LOCATIONS AND SIZES OF DUCT CONNECTIONS AND PIPING CONNECTIONS TO EQUIPMENT BEING PROVIDED BY OTHERS.

3. PROVIDE AND INSTALL MANUAL BALANCING DAMPERS IN ALL BRANCH DUCTWORK AND AT EACH AIR INLET AND OUTLET.

4. LOCATE ALL MANUAL BALANCING DAMPERS IN AN ACCESSIBLE LOCATION. WHERE DAMPERS ARE NOT ACCESSIBLE PROVIDE A MINIMUM 18X18 ACCESS DOOR.

5. UNLESS OTHERWISE NOTED, CONCEAL ALL DUCTWORK AND PIPING ABOVE CEILINGS, IN WALLS, OR INSIDE CHASES.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SUPPORTING SYSTEMS AND DEVICES FOR ALL DUCTWORK, EQUIPMENT, PIPING AND ACCESSORIES.

7. PROVIDE AND INSTALL SLEEVES FOR ALL DUCTWORK AND PIPING PASSING THROUGH WALLS AND FLOORS.

8. FOR DUCT CONNECTIONS TO TERMINAL DEVICES, FANS, AND OTHER EQUIPMENT SEE MECHANICAL DETAILS.

9. COORDINATE LOCATIONS OF ALL DIFFUSERS, GRILLES, AND REGISTERS WITH ARCHITECTURAL PLANS.

10. LOCATE AND INSTALL ALL MECHANICAL EQUIPMENT TO PROVIDE MANUFACTURER'S MINIMUM SERVICE CLEARANCES.

SA SUPPLY AIRRA RETURN AIREA EXHAUST AIROA OUTDOOR AIRCFM CUBIC FEET PER MINUTEIL INTAKE LOUVERRL RELIEF LOUVERMBTU THOUSAND BRITISH THERMAL UNITS PER HOURFD FIRE DAMPERNC NOISE CRITERIA

M

AD

EF-X

XX-X

T

24/24

X/X ∅

SYMBOL

RETURN DUCT UP OR TOWARD

SYMBOLDESCRIPTION DESCRIPTION

RETURN DUCT DOWN OR AWAY

EXHAUST DUCT UP OR TOWARD

EXHAUST DUCT DOWN OR AWAY

SUPPLY DUCT UP OR TOWARD

SUPPLY DUCT DOWN OR AWAY

SUPPLY DIFFUSER (WITH HARD DUCT)

SUPPLY DIFFUSER (WITH FLEXDUCT)

RETURN GRILLE OR REGISTER

RETURN GRILLE OR REGISTER

(WITH HARD DUCT)

(WITH FLEXDUCT)

EXHAUST GRILLE OR REGISTER

EXHAUST GRILLE OR REGISTER

(WITH HARD DUCT)

(WITH FLEXDUCT)

RECTANGULAR DUCT (FIRST FIGURE ISSIDE SHOWN) ALL DUCT DIMENSIONSARE INSIDE CLEAR DIMENSIONS

X∅ ROUND DUCTWORK

FLAT OVAL DUCTWORK

FLEXIBLE DUCTWORK

90° ELBOW WITH TURNING VANES

BRANCH DUCT TAP

ACCESS DOOR (HORIZONTAL/VERTICAL)

MOTORIZED DAMPER

FLEXIBLE DUCT CONNECTION TO EQUIPMENT

TRANSITION FROM RECTANGULAR TO ROUND DUCT

TO BE REMOVED

THERMOSTAT W/EQUIPMENT NUMBER

ROOF MOUNTED EXHAUST FANW/ EQUIPMENT NUMBER

DIRECTION OF AIRFLOW

1. VERIFY EXACT SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION.

2. DISCONNECT ALL HEATING DUCTWORK AND PIPING CONNECTIONS TO EQUIPMENT BEING REMOVED. CONTRACTOR SHALL COORDINATE WORK WITH ALL TRADES.

3. UNLESS OTHERWISE NOTED, REMOVAL DUCTWORK, PIPING AND/OR EQUIPMENT SHALL INCLUDE ALL INSULATION, DAMPERS, VALVES, HANGERS, SUPPORTS, EQUIPMENT PADS, FLASHING, CONTROLS, CONTROLS TUBING/WIRING AND ASSOCIATED ACCESSORIES.

4. UNLESS OTHERWISE NOTED, REMOVAL OF PIPING SHALL BE BACK TO THE MAIN OR LAST ACTIVE SERVICE.

5. ALL OPENINGS OR HOLES LEFT IN EXISTING WALLS, FLOORS, AND CEILINGS TO REMAIN, INCLUDING CHASES, SHALL BE PATCHED TO MATCH EXISTING CONDITIONS. PATCHING SHALL BE IN ACCORDANCE WITH THE APPROPRIATE DIVISION OF THE SPECIFICATIONS.

6. THE CONTRACTOR SHALL DISCONNECT EXISTING BUILDING TEMPERATURE CONTROL SYSTEM FROM THE NETWORK AND PROVIDE ALL WORK ASSOCIATED WITH DEMOLITION.

7. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED WORK TO MAINTAIN THE CONTINUITY OF THE EXISTING NETWORK UNTIL NEW NETWORK HAS BEEN ESTABLISHED.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

2 PM

HEATING ANDVENTILATION GENERALNOTES, SYMBOLS ANDABBREVIATIONS

H001AJMNTPAJM

M1600010

GENERAL HEATING/VENTILATION NOTESHEATING/VENTILATION ABBREVIATIONSHVAC LEGEND

HVAC GENERAL DEMOLITION NOTES

No. Description Date

Page 22: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

15"x

12" (

SA)

24"x12" (SA) 20"x12" (SA) 16"x12" (SA)

20"x20" (SA)

10"x

8" (S

A)

1. EXISTING MEDIUM PRESSURE DUCTWORK CONTINUES AND IS NOT SHOWN. NO WORK BEYOND THIS POINT.

2. EXISTING SA DUCTWORK UP TO FLOOR GRILLE TO REMAIN.3. EXISTING MEDIUM PRESSURE DUCTWORK TO REMAIN AND BE

REUSED.4. EXISTING VAV BOX AND REHEAT COIL TO REMAIN AND BE REUSED.

EXISITNG HWS AND HWR PIPING INCLUDING CONTROL VALVES AND BALANCING VALVES TO REMAIN.

5. EXISTING FIRE DAMPER TO REMAIN.6. EXISTING MEDIUM PRESSURE SA DUCTWORK TO REMAIN. EXISTING

EQUIPMENT, RETURN DUCTWORK, AND DUCTWORK ASSOCIATED WITH AHU-2 NOT SHOWN.

7. EXISTING AIR HANDLING UNIT TO REMAIN.8. EXISTING SA DUCT ALONG WALL TO REMAIN.9. EXISTING VAV BOX, LOW PRESSURE SA DUCTWORK, FLEX DUCT, AND

CELING GRILLES SERVING BASEMENT TO REMAIN.

1. REMOVE EXISTING SA BRANCH DUCTS UP TO FIRST FLOOR. PATCH OPENING IN DUCTWORK AIR TIGHT. EXISTING DUCT HEADER TO REMAIN IN PLACE.

2. REMOVE EXISTING SA DUCT ENDCAP TO MAKE CONNECTION TO NEW DUCTWORK.

3. REMOVE EXISTING SA DUCTWORK TO APPROXIMATE LOCATION SHOWN FOR CONNECTION TO NEW SA DUCTWORK.

4. REMOVE LOW PRESSURE SA DUCTWORK FROM VAV BOX TO FLOOR GRILLE. SEE H-200 FOR NEW WORK.

5. REMOVE THREE (3) EXISTING SA GRILLES. PATCH OPENING IN DUCTWORK AIR TIGHT.

1. SEE SHEET H-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

2. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR TO CONSTRUCTION. VARIOUS EXISTING UTILITIES TO REMAIN. CONTRACTOR SHALL COORDINATE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES AND AVOID CONFLICT.

3. REMOVE EXISTING FIRE DAMPERS ASSOCIATED WITH DEMOLISHED DUCTWORK. REPAIR WALL TO MEET FIRE RATING OF EXISTING WALL.

4. PATCH AND PAINT EXISTING OPENINGS IN WALLS CREATED FROM HVAC WORK TO MATCH EXISTING.

5. REMOVE EXISTING SOFFITS IN BASEMENT TO ALLOW ACCESS TO DUCTWORK. REPLACE SOFFIT WITH SAME CONSTRUCTION TO MAINTAIN ROOM RATING.

6. COORDINATE PAINTING OF EXISTING/NEW DUCTWORK WITH ARHICTECT.

7. CONTRACTOR SHALL VERIFY OPERATION OF ALL EXISTING EQUIPMENT AND SUBMIT TESTING AND BALANCING REPORT FOR AIR AND WATER SYSTEMS TO ENGINEER FOR REVIEW PRIOR TO ANY CONSTRUCTION.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

4 PM

LOWER LEVEL HVACDEMOLITION PLAN

H100AJMNTPAJM

M1600010

0 1' 2' 4' 8'

BASEMENT HVAC DEMOLITION PLAN1

1

1

MECHANICAL KEYNOTES (THIS SHEET)MECHANICAL DEMO NOTES (THIS SHEET)

1 1

2

33

4

4 4

5

6

7

AHU-1

7

AHU-2

3

GENERAL NOTES (THIS SHEET) ##

8

8

9

(TYP.)(TYP.)

2

11

4

555

5

5

No. Description Date

Page 23: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

T T T

1. EXISTING FLOOR GRILLE TO REMAIN.2. EXISTING RA DUCTWORK ABOVE CEILING TO REMAIN.3. EXISTING MASTER THERMOSTAT TO REMAIN.4. EXISTING THERMOSTAT TO REMAIN. TAG INDICATES THERMOSTAT

NUMBER.

1. REMOVE EXISTING LINEAR AIR TERMINAL ALONG WALL, INCLUDING ASSOCIATED VERTICAL DUCTWORK. SEE ARCHITECTURAL SHEETS FOR FLOOR FINISHING.

2. REMOVE EXISTING WALL MOUNTED RETURN GRILLE. GRILLE WILL BE REPLACED WITH LARGER GRILLE. SEE NEW WORK PLAN.

3. REMOVE EXISTING FLOOR REGISTER. REGISTER WILL BE REPLACED WITH A LARGER REGISTER. SEE NEW WORK PLAN. REFER TO LOWER LEVEL DEMOLITION PLAN FOR DUCTWORK REMOVAL.

4. REMOVE EXISITNG WALL MOUNTED RETURN GRILLE. EXISTING OPENING TO REMAIN AND BE REUSED.

1. SEE SHEET H-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.2. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES

PRIOR TO CONSTRUCTION. VARIOUS EXISTING UTILITIES TO REMAIN. CONTRACTOR SHALL COORDINATE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES AND AVOID CONFLICT.

3. PATCH AND PAINT EXISTING OPENINGS IN WALLS CREATED FROM HVAC WORK TO MATCH EXISTING.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND REPLACING ALL CEILING TILES REQUIRED TO INSTALL THEIR WORK.

5. PROVIDE NEW CEILING TILES WHERE EXISTING CEILING TILES ARE DAMAGED DURING WORK OR REPLACEMENT CEILING TILES ARE REQUIRED WHERE EXISTING GRILLES/DIFFUSERS ARE REMOVED.

6. PROVIDE NEW CEILING GRID WHERE REQUIRED TO ALLOW INSTALLATION OF NEW DUCT/DIFFUSER/GRILLES.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

5 PM

FIRST FLOOR HVACDEMOLITION PLAN

H101AJMNTPAJM

M1600010

0 1' 2' 4' 8'

FIRST FLOOR HVAC DEMOLITION PLAN1

MECHANICAL KEYNOTES (THIS SHEET)

MECHANICAL DEMO NOTES (THIS SHEET)

1

1

2

3

1

3 4

T114

T12

2

2

#

#GENERAL NOTES (THIS SHEET)

4 No. Description Date

Page 24: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

1

TYP.

TYP.

STORAGE

STORAGE

STORAGE

MECHANCIAL

ENTRY(ABOVE)

STORAGE

15"x

12" (

SA)

24"x12" (SA) 20"x12" (SA) 16"x12" (SA)

20"x20" (SA)

8"ø

(SA)

8"ø (SA) 10"x10" (SA)

8"ø (SA)

8"ø (SA)

8"ø (SA)

8"ø

(SA)

1. SEE SHEET H-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.2. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES

PRIOR TO CONSTRUCTION. VARIOUS EXISTING UTILITIES TO REMAIN. CONTRACTOR SHALL COORDINATE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES AND AVOID CONFLICT.

3. PATCH AND PAINT EXISTING OPENINGS IN WALLS CREATED FROM HVAC WORK TO MATCH EXISTING.

4. REMOVE EXISTING SOFFITS IN BASEMENT TO ALLOW ACCESS TO DUCTWORK. REPLACE SOFFIT WITH SAME CONSTRUCTION TO MAINTAIN ROOM RATING.

5. COORDINATE PAINTING OF EXISTING/NEW DUCTWORK WITH ARHICTECT. 6. CONTRACTOR SHALL VERIFY OPERATION OF ALL EXISTING EQUIPMENT

AND SUBMIT TESTING AND BALANCING REPORT FOR AIR AND WATER SYSTEMS TO ENGINEER FOR REVIEW PRIOR TO ANY CONSTRUCTION.

7. RE-BALANCE EXISTING VAV BOXES, REHEAT COILS, GRILLES, DIFFUSERS, OPENINGS, FANS, AND AIR HANDLING UNITS TO AIR FLOW INDICATED ON DRAWINGS OR TO ACCOMMODATE FOR REVISED AIR AND WATER FLOWRATES.

1. NEW 12x4 SA DUCT UP TO FLOOR GRILLE ON FLOOR ABOVE. COORDINATE EXACT LOCATION OF DUCTWORK AND GRILLE IN FIELD TO AVOID CONFLICT WITH NEW/EXISTING UTILITIES AND FURNITURE.

2. NEW SA DUCTWORK ROUTED AT CEILING.3. EXISTING VAV BOX AND REHEAT COIL TO REMAIN.4. EXISTING SA DUCTWORK TO REMAIN.5. EXISTING AHU TO REMAIN. REBALANCE FAN TO PROVIDE REVISED

AIRFLOW AS INDICATED ON DRAWINGS.6. VERIFY PRESENCE OF 3-HOUR RATED FIRE DAMPER AT WALL.7. BALANCING DAMPER.8. PROVIDE NEW 3-HOUR RATED FIRE DAMPER AT WALL. REFER TO DETAIL

2 THIS SHEET.9. MAKE CONNECTION TO EXISTING SA DUCTWORK WITH NEW DUCT.10. NEW SA DUCT FROM VAV BOX UP TO NEW FLOOR GRILLE. TRANSITION

TO 18x4 FLOOR GRILLE SIZE. COORDINATE EXACT LOCATION OF DUCTWORK AND GRILLE IN FIELD TO AVOID CONFLICT WITH NEW AND EXISTING UTILITIES.

11. EXISTING AHU TO REMAIN. UNIT IS NOT AFFECTED BY THIS WORK.FACTORYFABRICATED SLEEVE

FIRE DAMPER

165° FUSIBLE LINK

DUCTWORK

FIRE-RATED WALLOR PARTITION

1-1/2" x 1-1/2" x 1/8"ANGLES FASTENED TOSLEEVE. DO NOT FASTEN TOWALL.

FASTEN DUCT TOSLEEVE WITH S CLIPS

12"x12" DUCT ACCESSDOOR AT FIREDAMPER. IF DUCT ISLESS THAN 12" INHEIGHT, DOOR SHALLBE 1" LESS THANDUCT HEIGHT

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

7 PM

LOWER LEVEL HVACPLAN

H200AJMNTPAJM

M1600010

0 1' 2' 4' 8'

LOWER LEVEL HVAC NEW WORK PLAN1

GENERAL NOTES MECHANICAL KEYNOTES (THIS SHEET)

REST ROOM

2

(TYP. 7)

3 3

3

4

4

(TYP.)

(TYP.)

5AHU-1

11

AHU-2

6

6

8

4

1

1

4

4

10

2

2

2

2

2

9

RH-11

3

RH-3

RH-12

RH-4

#

7

(TYP.)

7 (TYP.)

9

9

9

9

N.T.S.FIRE DAMPER INSTALLATION DETAIL

2

1

1

1

No. Description Date

6

6

Page 25: t KANE COUNTY DEPARTMENT OF …...H201 FIRST FLOOR HVAC PLAN AD-201 FIRST FLOOR DEMOLITION PLAN AD-801 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN GENERAL ARCHTIECTURAL ELECTRICAL

T T T

1 (TYP. 12)

OFFICE

ENTRY

STAIR #1

MEN'SWOMEN'S

BREAK ROOM

CONFERENCEROOM

LOBBY

A1

150 CFM

A1

150 CFM

A1

150 CFM

A1

125 CFMA1

125 CFM

A1

150 CFMA1

150 CFMA1

150 CFMA1

150 CFMA1

150 CFM

E

200 CFM

A2

200 CFM

A1

125 CFM

A1

125 CFM

E

1150 CFM

R1

550 CFM

R2

200 CFM

1. NEW FLOOR SUPPLY GRILLE.2. EXISTING FLOOR SUPPLY GRILLE TO REMAIN.3. NEW RETURN GRILLE OF SAME SIZE.4. NEW RETURN GRILLE IN CEILING. CONNECT TO EXISTING RA DUCTWOK

ABOVE CEILING.5. EXISTING MASTER THERMOSTAT CONTROLLING THE CONDENSING UNIT

TO REMAIN.6. EXISTING THERMOSTAT TO REMAIN. TAG INDICATES EXISTING

THERMOSTAT NUMBER. THERMOSTATS T11 AND T12 SHALL BE RECONFIGURED SUCH THAT NEW FIRST FLOOR OFFICE SPACE IS CONTROLLED AS A SINGLE ZONE.

1. SEE SHEET H-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.2. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR

TO CONSTRUCTION. VARIOUS EXISTING UTILITIES TO REMAIN. CONTRACTOR SHALL COORDINATE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES AND AVOID CONFLICT.

3. PATCH AND PAINT EXISTING OPENINGS IN WALLS CREATED FROM HVAC WORK TO MATCH EXISTING.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND REPLACING ALL CEILING TILES REQUIRED TO INSTALL THEIR WORK.

5. PROVIDE NEW CEILING TILES WHERE EXISTING CEILING TILES ARE DAMAGED DURING WORK OR REPLACEMENT CEILING TILES ARE REQUIRED WHERE EXISTING GRILLES/DIFFUSERS ARE REMOVED.

6. PROVIDE NEW CEILING GRID WHERE REQUIRED TO ALLOW INSTALLATION OF NEW DUCT/DIFFUSER/GRILLES.

7. CONTRACTOR SHALL VERIFY OPERATION OF ALL EXISTING EQUIPMENT AND SUBMIT TESTING AND BALANCING REPORT FOR AIR AND WATER SYSTEMS TO ENGINEER FOR REVIEW PRIOR TO ANY CONSTRUCTION.

8. RE-BALANCE EXISTING VAV BOXES, REHEAT COILS, GRILLES, DIFFUSERS, OPENINGS, FANS, AND AIR HANDLING UNITS TO AIR FLOW INDICATED ON DRAWINGS OR TO ACCOMMODATE FOR REVISED AIR AND WATER FLOWRATES.

NOT FOR CONSTRUCTION

2018, Muller & Muller, Ltd.

312.432.4180312.432.4184

700 N SangamonChicago, IL 60642

tf

SHEET NO.DRAWN:CHECKED:DESIGNED:JOB NO:

1 ISSUED FOR 10% DESIGN 05/08/20182 ISSUED FOR 30% DESIGN 07/23/2018

KAN

E C

OU

NTY

DEP

ARTM

ENT

OF

TRAN

SPO

RTA

TIO

N(K

DO

T)O

FFIC

E R

ENO

VATI

ON

41W

011

BUR

LIN

GTO

N R

OAD

CAM

PTO

N H

ILLS

, IL

6017

5

Professional Seals

MULLER & MULLER, LTD. (M2) EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN CONSENT OF MULLER & MULLER, LTD. (M2)

3 ISSUED FOR 100% DESIGN 09/12/2018

C:\U

sers

\am

ayka

\Do c

umen

ts\M

1600

010

Cen

tral

File

_ AM

ayka

.rvt

9/12

/201

8 5:

16:2

9 PM

FIRST FLOOR HVACPLAN

H201AJMNTPAJM

M1600010

0 1' 2' 4' 8'

FIRST FLOOR HVAC NEW WORK PLAN1

MECHANICAL KEYNOTES (THIS SHEET)

OFFICE

2

4

3

3

#

GENERAL NOTES (THIS SHEET)

56

T11

6 T12

8/8

RA

No. Description Date


Recommended