6-1 © 2009 Schneider Electric All Rights Reserved 6 SURGE PROTECTIVE DEVICES Table of Contents Section 6 Surge Protective Devices EMA/EBA, page 6–2 Commercial Applications HWA, page 6–6 Panelboards, page 6–4 Busway, page 6–4 Residential & Light Commercial Applications Surgebreaker Plus, page 6–8 QO/HOM Surge Arresters, page 6–8 SDSA Hard Wired, page 6–7 OEM Applications XR Surge Suppressor, page 6–6 LC Surge Suppressor/ Noise Filter, page 6–7 Multi 9 DIN Rail Mounted Surge Suppressor, page 6–5 Externally Mounted Surge Protective Devices Modular External SPD—EMA Series 6-2 Non-Modular External SPD—EBA Series 6-2 10 Mode Modular External SPD 6-2 High Resistance Ground (HRG) External SPD 6-2 Replacement Modules 6-3 Internally Mounted Surge Protective Devices—New Construction Panelboards—Refer to 9-1 Switchboards and Switchgear—Refer to 11-1 Model 6 Motor Control Centers—Refer to 17-1 IPaCS—Refer to 10-1 Busway—Refer to 12-1 Internally Mounted Surge Protective Devices—Retrofit I-Line ® Branch Units 6-4 QMB Branch Units 6-4 Busway Plug-in Units 6-4 Model 6 Motor Control Centers 6-4 Surgelogic OEM/Assembler Kit 6-5 DIN Rail Mounted Multi 9 Surge Protective Devices DIN Rail Mounted Multi 9 Surge Protective Devices 6-5 Nipple Mounted Surge Protective Devices HWA Series Non-Modular, Nipple Mounted Device 6-6 XW Series Non-Modular, Nipple Mounted Device 6-6 XR Series Nipple Mounted Surge Protective Device 6-6 LC Series In-Line Surge Protective Device and Noise Filter 6-7 Secondary Surge Arresters 6-7 Mounting Brackets 6-7 Residential Surge Protective Devices Surgebreaker ® Whole House Surge Protective Devices 6-8 Surgebreaker ® Plus Low-Voltage Only Surge Suppressor 6-8 Surgebreaker ® Plus Accessories 6-8 QO ® , NQ, and Homeline ® Panelboard Surge Arresters 6-8 New! New! New! New! New! Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Transcript
Page 1: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

6-1© 2009 Schneider ElectricAll Rights Reserved

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

Table of Contents

Section 6Surge Protective Devices

EMA/EBA, page 6–2

Commercial Applications

HWA,page 6–6

Panelboards,page 6–4

Busway,page 6–4

Residential & Light Commercial Applications

Surgebreaker Plus,page 6–8

QO/HOMSurge Arresters,

page 6–8

SDSA Hard Wired,page 6–7

OEM Applications

XR Surge Suppressor,page 6–6

LC Surge Suppressor/Noise Filter,

page 6–7

Multi 9 DIN Rail Mounted Surge Suppressor, page 6–5

Externally Mounted Surge Protective Devices

Modular External SPD—EMA Series 6-2

Non-Modular External SPD—EBA Series 6-2

10 Mode Modular External SPD 6-2

High Resistance Ground (HRG) External SPD 6-2

Replacement Modules 6-3

Internally Mounted Surge Protective Devices—New Construction

Panelboards—Refer to 9-1

Switchboards and Switchgear—Refer to 11-1

Model 6 Motor Control Centers—Refer to 17-1

IPaCS—Refer to 10-1

Busway—Refer to 12-1

Internally Mounted Surge Protective Devices—Retrofit

I-Line® Branch Units 6-4

QMB Branch Units 6-4

Busway Plug-in Units 6-4

Model 6 Motor Control Centers 6-4

Surgelogic OEM/Assembler Kit 6-5

DIN Rail Mounted Multi 9™ Surge Protective Devices

DIN Rail Mounted Multi 9™ Surge Protective Devices 6-5

Nipple Mounted Surge Protective Devices

HWA Series Non-Modular, Nipple Mounted Device 6-6

XW Series Non-Modular, Nipple Mounted Device 6-6

XR Series Nipple Mounted Surge Protective Device 6-6

LC Series In-Line Surge Protective Device and Noise Filter 6-7

Secondary Surge Arresters 6-7

Mounting Brackets 6-7

Residential Surge Protective Devices

Surgebreaker® Whole House Surge Protective Devices 6-8

Surgebreaker® Plus Low-Voltage Only Surge Suppressor 6-8

Surgebreaker® Plus Accessories 6-8

QO®, NQ, and Homeline® Panelboard Surge Arresters 6-8

New!

New!

New!

New!

New!

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 2: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

6-2 © 2009 Schneider ElectricAll Rights Reserved

Surge Protective Devices Externally Mounted Surge Protective DevicesClass 1310 / Refer to Catalog 6671CT9701

Modular External SPDExternal Modular Assembly (EMA) SPD products feature a design based on modules for a flexible, cost effective way to achieve superior protection at every level of the electrical distribution system. Modularity means lower life cycle costs and fast, easy service or replacement.

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240b Can be used on 4-wire or 3-wire grounded neutral system.

( ) For option, select and add the appropriate suffix from the option listing below:

Non-Modular External SPDNon-modular External Brick Assembly (EBA) SPD products consist of a consolidation of phase modules into one solid “brick” casting and offered at a competitive price for those who want great protection on a limited budget.

a Can be used on 4 wire or 3 wire grounded neutral system.b 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

( ) For options, select and add the appropriate suffix from the option listing below:

10 Mode Modular External SPDThe 10-Mode (All Mode) SPD is an external modular parallel system that provides discrete surge suppression paths for all ten modes (L-L, L-N, L-G, N-G). Optional Sine Wave Tracker (SWT) circuitry establishes the power surge clamping window relative to the sine wave voltage to provide increased performance at distribution and branch panel applications.• 10 year product warranty• Audible alarm, dry contacts and surge counter are included in the standard

diagnostic package• Standard internal 200 kA IC fault rated fusing, 200 kA SCCR

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240( ) For option, select and add the appropriate suffix from the following listing:

High Resistance Ground (HRG) Modular External SPDThe Surgelogic® High Resistance Ground (HRG) SPD is an external modular parallel system that provides protection from transients referenced phase to phase and phase to ground and is designed specifically for HRG configured systems.

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

Option Descriptions• Integral Switch. The integral switch provides a mechanical means to

electrically isolate the entire surge suppressor before opening the enclosure door to facilitate servicing of the unit’s components.

• Remote Monitor. This option displays the alarm status of the surge protective device up to 1000 feet from the unit.

• Flush Mounting. Flush mounting collar can be used on 120–240 kA EMA and EBA series devices. Devices with integral switch require 20” flush mounting collar.

Surgelogic®

Surgelogic® Surge Protective Device (SPD) products offer the world’s finest array of solutions for electrical distribution systems. From simple to mission-critical applications in commercial, industrial, and OEM design, the comprehensive Surgelogic® line provides devices for every need.

Externally Mounted Surge Protective DevicesSurgelogic® offers a full range of externally mountable SPDs. These units are designed to provide protection against surges from service entrance panels down to point of use equipment.Listed to UL1449 Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009), and UL 1283 where applicable. Meets requirements of ANSI/IEEE C62.41.1, C62.41.2, and C62.45.

• 10 year product warranty• Standard product protection modes L-N, L-G, L-L, and N-G• Standard internal 200 kA AIC surge rated fusing, 200 kA SSCR

• Audible alarm with enable/disable switch, dry contacts, and surge counter standard

• Indicator LEDs; normal (green) and fault condition (red) for each phase

Table 6.1: EMA Series Modular Device

Service Voltage

Peak Surge Current Rating

per Phase(kA)

NEMA 1/3R/12 Cat. No. $ Price

NEMA 4X Stainless Steel

Cat. No. $ Price

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.

120/240 V,1-phase, 3-wire

+ground

120 TVS1EMA12A( ) 4547.00 TVS1EMA12S( ) 5964.00160 TVS1EMA16A( ) 4997.00 TVS1EMA16S( ) 6414.00240 TVS1EMA24A( ) 7421.00 TVS1EMA24S( ) 8838.00320 TVS1EMA32A( ) 9962.00 — —480 TVS1EMA48A( ) 14798.00 — —

208Y/120 V,3-phase, 4-wire

+ground b

120 TVS2EMA12A( ) 4760.00 TVS2EMA12S( ) 6177.00160 TVS2EMA16A( ) 5231.00 TVS2EMA16S( ) 6648.00240 TVS2EMA24A( ) 7782.00 TVS2EMA24S( ) 9200.00320 TVS2EMA32A( ) 10431.00 — —480 TVS2EMA48A( ) 15522.00 — —

120/240 V,3-phase, 4-wire

+groundHigh-leg Delta

120 TVS3EMA12A( ) 4760.00 TVS3EMA12S( ) 6177.00160 TVS3EMA16A( ) 5231.00 TVS3EMA16S( ) 6648.00240 TVS3EMA24A( ) 7782.00 TVS3EMA24S( ) 9200.00320 TVS3EMA32A( ) 10431.00 — —480 TVS3EMA48A( ) 15522.00 — —

480Y/277 V,3-phase, 4-wire+ground a b

120 TVS4EMA12A( ) 4973.00 TVS4EMA12S( ) 6390.00160 TVS4EMA16A( ) 5468.00 TVS4EMA16S( ) 6885.00240 TVS4EMA24A( ) 8147.00 TVS4EMA24S( ) 9564.00320 TVS4EMA32A( ) 10904.00 — —480 TVS4EMA48A( ) 16250.00 — —

600Y/347 V,3-phase, 4-wire

+ground b

120 TVS8EMA12A( ) 5220.00 TVS8EMA12S( ) 6638.00160 TVS8EMA16A( ) 5714.00 TVS8EMA16S( ) 7131.00240 TVS8EMA24A( ) 8528.00 TVS8EMA24S( ) 9945.00320 TVS8EMA32A( ) 11399.00 — —480 TVS8EMA48A( ) 17012.00 — —

Table 6.2: EBA Series Non-Modular Device

Service Voltage

Peak Surge Current Rating per Phase (kA)

NEMA 1/3R/12 Cat. No. $ Price

NEMA 4X Stainless Steel

Cat. No. $ Price

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.120/240 V,

1-phase, 3-wire+ground

120 TVS1EBA12A( ) 3467.00 TVS1EBA12S( ) 4884.00160 TVS1EBA16A( ) 4208.00 TVS1EBA16S( ) 5625.00240 TVS1EBA24A( ) 6290.00 TVS1EBA24S( ) 7707.00

208Y/120 V,3-phase, 4-wire

+ground a

120 TVS2EBA12A( ) 3588.00 TVS2EBA12S( ) 5006.00160 TVS2EBA16A( ) 4388.00 TVS2EBA16S( ) 5805.00240 TVS2EBA24A( ) 6525.00 TVS2EBA24S( ) 7943.00

120/240 V, 3-phase, 4-wire +ground High-leg Delta

120 TVS3EBA12A( ) 3588.00 TVS3EBA12S( ) 5006.00160 TVS3EBA16A( ) 4388.00 TVS3EBA16S( ) 5805.00240 TVS3EBA24A( ) 6525.00 TVS3EBA24S( ) 7943.00

480Y/277 V,3-phase, 4-wire+ground a b

120 TVS4EBA12A( ) 3743.00 TVS4EBA12S( ) 5160.00160 TVS4EBA16A( ) 4581.00 TVS4EBA16S( ) 5999.00240 TVS4EBA24A( ) 6827.00 TVS4EBA24S( ) 8244.00

600Y/347 V,3-phase, 4-wire

+ground a

120 TVS8EBA12A( ) 3905.00 TVS8EBA12S( ) 5322.00160 TVS8EBA16A( ) 4787.00 TVS8EBA16S( ) 6204.00240 TVS8EBA24A( ) 7143.00 TVS8EBA24S( ) 8561.00

Option $ Price

(I) Integral Switch 492.00

Table 6.3: 10 Mode Modular Devices

Service Voltage

Peak Surge Current Rating

per Phase (kA)

NEMA 1/3R/12 Cat. No. $ Price

NEMA 4X Stainless Steel

Cat. No. $ Price

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.

208Y/120 V,3-phase, 3-4 wire

120 TVS2MEMA12A( ) 8810. TVS2MEMA12S( ) 6927.180 TVS2MEMA18A( ) 10790. TVS2MEMA18S( ) 12657.270 TVS2MEMA27A( ) 13760. TVS2MEMA27S( ) 15627.360 TVS2MEMA36A( ) 16730. TVS2MEMA36S( ) 18597.

480Y/277 V,3-phase,

3-4 wire a

120 TVS4MEMA12A( ) 9023. TVS4MEMA12S( ) 10890.180 TVS4MEMA18A( ) 11003. TVS4MEMA18S( ) 12870.270 TVS4MEMA27A( ) 13973. TVS4MEMA27S( ) 15840.360 TVS4MEMA36A( ) 16943. TVS4MEMA36S( ) 18810.

600Y/347 V,3-phase, 3-4 wire

120 TVS8MEMA12A( ) 9270. TVS8MEMA12S( ) 10677.180 TVS8MEMA18A( ) 11250. TVS8MEMA18S( ) 13118.270 TVS8MEMA27A( ) 14220. TVS8MEMA27S( ) 16088.320 TVS8MEMA32A( ) 17190. TVS8MEMA32S( ) 19058.

Option $ Price

(SWT) Sine Wave Tracking 800.00

Table 6.4: HRG Modular Device

Service Voltage

Peak Surge

Current Rating

per Phase (kA)

NEMA 1/3R/12Cat. No. $ Price

NEMA 1/3R/12 with Integral

Switch Cat. No.

$ Price

NEMA 4X Stainless Steel

with Integral Switch Cat. No.

$ Price

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.480Y/277 V,3-phase, a4-wire HRG

120 TVS4HEMA12A 5723. TVS4HEMA12AI 9645. TVS4HEMA12SI 12690.160 TVS4HEMA16A 7043. TVS4HEMA16AI 10965. TVS4HEMA16SI 14010.200 TVS4HEMA20A 8363. TVS4HEMA20AI 12285. TVS4HEMA20SI 15330.

600Y/347 V,3-phase,

4-wire HRG

120 TVS8HEMA12A 5970. TVS8HEMA12AI 9893. TVS8HEMA12SI 12938.160 TVS8HEMA16A 7290. TVS8HEMA16AI 11213. TVS8HEMA16SI 14258.200 TVS8HEMA20A 8610. TVS8HEMA20AI 12533. TVS8HEMA20SI 15578.

Description Cat. No. $ Price

Remote Monitor TVS12RMU 788.12" Flush Mounting Collar TVS12FMK 945.20" Flush Mounting Collar TVS20FMK 1103.

New!

New!

DE1B Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 3: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

© 2009 Schneider ElectricAll Rights Reserved

6-3

Surge Protective Devices Replacement ModulesRefer to Catalog 6671CT9701

Replacement Modules

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240b High-leg delta (Phase B modules are different than Phase A and Phase C modules)

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

10 Mode Modular External SPD

Non-Modular External SPD with Integral Switch

Modular External SPD with Integral Switch

HRG External SPD

Table 6.5: EMA Series Replacement Modules

System Voltage

Peak Surge Current Rating

(kA)

Catalog Numbers

Phase A $ Price Phase B $ Price Phase C $ Price

120/240 V, 1-phase,

3-wire

120 MA1IMA12 906.00 — — MA1IMA12 906.00160 MA1IMA16 1064.00 — — MA1IMA16 1064.00240 MA1IMA24 1229.00 — — MA1IMA24 1229.00

208Y/120 V, 3-phase,

4-wire

120 MA1IMA12 906.00 MA1IMA12 906.00 MA1IMA12 906.00160 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00240 MA1IMA24 1229.00 MA1IMA24 1229.00 MA1IMA24 1229.00

120/240 V, 3-phase, 4-wire b

120 MA1IMA12 906.00 MA3IMA12 906.00 MA1IMA12 906.00160 MA1IMA16 1064.00 MA3IMA16 1064.00 MA1IMA16 1064.00240 MA1IMA24 1229.00 MA3IMA24 1229.00 MA1IMA24 1229.00

480Y/277 V, 3-phase, 4-wire a

120 MA4IMA12 906.00 MA4IMA12 906.00 MA4IMA12 906.00160 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00240 MA4IMA24 1229.00 MA4IMA24 1229.00 MA4IMA24 1229.00

600/347 V, 3-phase,

4-wire

120 MA8IMA12 906.00 MA8IMA12 906.00 MA8IMA12 906.00160 MA8IMA16 1064.00 MA8IMA16 1064.00 MA8IMA16 1064.00240 MA8IMA24 1229.00 MA8IMA24 1229.00 MA8IMA24 1229.00

Table 6.6: EBA Series Replacement ModulesSystem Voltage Peak Surge Current Rating (kA) Catalog Numbers $ Price

120/240 V,1-phase, 3-wire

120 MA1IBA12 1811.00160 MA1IBA16 2126.00240 MA1IBA24 2457.00

208Y/120 V, 3-phase, 3-4 wire

120 MA2IBA12 1811.00160 MA2IBA16 2126.00240 MA2IBA24 2457.00

240/120 V, 3-phase, 4-wire,high-leg delta

120 MA3IBA12 1811.00160 MA3IBA16 2126.00240 MA3IBA24 2457.00

480Y/277 V, 3-phase,

3-4 wire a

120 MA4IBA12 1811.00160 MA4IBA16 2126.00240 MA4IBA24 2457.00

600Y/347 V, 3-phase, 3-4 wire

120 MA8IBA12 1811.00160 MA8IBA16 2126.00240 MA8IBA24 2457.00

Table 6.7: 10 Mode MA (L-N, L-G) Replacement Modules

System Voltage

Peak Surge Current Rating

(kA)

Catalog Numbers

Phase A $ Price Phase B $ Price Phase C $ Price

208Y/120 V,3-phase,3-4 wire

120 MA1IMA12 906.00 MA1IMA12 906.00 MA1IMA12 906.00180 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00270 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00360 MA1IMA24 1229.00 MA1IMA24 1229.00 MA1IMA24 1229.00

480Y/277 V, 3-phase,

3-4 wire a

120 MA4IMA12 906.00 MA4IMA12 906.00 MA4IMA12 906.00180 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00270 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00360 MA4IMA24 1229.00 MA4IMA24 1229.00 MA4IMA24 1229.00

600Y/347 V, 3-phase, 3-4 wire

120 MA8IMA12 906.00 MA8IMA12 906.00 MA8IMA12 906.00180 MA8IMA16 1064.00 MA8IMA16 1064.00 MA8IMA16 1064.00270 MA8IMA24 1229.00 MA8IMA24 1229.00 MA8IMA24 1229.00320 MA8IMA24 1229.00 MA8IMA24 1229.00 MA8IMA24 1229.00

Table 6.8: 10 Mode L-L Replacement Modules

System Voltage

Peak Surge Current Rating

(kA)

Catalog Numbers

Phase A $ Price Phase B $ Price Phase C $ Price

208Y/120 V,3-phase,3-4 wire

120 MA2IMA40LL 604.00 MA2IMA40LL 604.00 MA2IMA40LL 604.00180 MA2IMA60LL 709.00 MA2IMA60LL 709.00 MA2IMA60LL 709.00270 MA2IMA90LL 819.00 MA2IMA90LL 819.00 MA2IMA90LL 819.00360 MA2IMA12LL 946.00 MA2IMA12LL 946.00 MA2IMA12LL 946.00

480Y/277 V, 3-phase,

3-4 wire a

120 MA4IMA40LL 604.00 MA4IMA40LL 604.00 MA4IMA40LL 604.00180 MA4IMA60LL 709.00 MA4IMA60LL 709.00 MA4IMA60LL 709.00270 MA4IMA90LL 819.00 MA4IMA90LL 819.00 MA4IMA90LL 819.00360 MA4IMA12LL 946.00 MA4IMA12LL 946.00 MA4IMA12LL 946.00

600Y/347 V, 3-phase, 3-4 wire

120 MA8IMA40LL 604.00 MA8IMA40LL 604.00 MA8IMA40LL 604.00180 MA8IMA60LL 709.00 MA8IMA60LL 709.00 MA8IMA60LL 709.00270 MA8IMA90LL 819.00 MA8IMA90LL 819.00 MA8IMA90LL 819.00320 MA8IMA12LL 946.00 MA8IMA12LL 946.00 MA8IMA12LL 946.00

Table 6.9: HRG Replacement Modules

System Voltage

Peak Surge Current Rating

(kA)

Catalog Numbers

Phase A $ Price Phase B $ Price Phase C $ Price

480Y/277V, 3-phase,

4-wire, HRG a

120 MA4IMA12H 804.00 MA4IMA12H 804.00 MA4IMA12H 804.00160 MA4IMA16H 944.00 MA4IMA16H 944.00 MA4IMA16H 944.00200 MA4IMA20H 1084.00 MA4IMA20H 1084.00 MA4IMA20H 1084.00

600Y/347V,3-phase,

4-wire, HRG

120 MA8IMA12H 804.00 MA8IMA12H 804.00 MA8IMA12H 804.00160 MA8IMA16H 944.00 MA8IMA16H 944.00 MA8IMA16H 944.00200 MA8IMA20H 1084.00 MA8IMA20H 1084.00 MA8IMA20H 1084.00

New!

PE4 PE7 PE1A Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 4: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

6-4 © 2009 Schneider ElectricAll Rights Reserved

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

Surge Protective Devices Internally Mounted Surge Protective DevicesRefer to Catalog 6671CT9701

Internally Mounted Surge Protective DevicesSurge protective devices installed internally or integral to systems for service entrance and branch panel protection against damaging surges. No SPDs in the industry that can compete with the performance of integrally/internally mounted products installed next to the supply busses inside Square D® systems. Built-in performance is the best way to ensure cost effective power quality (especially important for critical power facilities).

Internally Mounted—New ConstructionSurgelogic® SPD products with integral/internal performance make new construction projects easy with factory installed surge protection. Refer to the sections listed below to identify the correct product for your application or contact TVSS TAG at 1-800-577-7353 for assistance.

Busway—Refer to Section 12

Internally Mounted—RetrofitTo ensure high-performance surge protection at critical power locations, A variety of Surgelogic® products are offered which are designed specifically for retrofitting into commonly used Square D® systems. Retrofitting SPD units on I-Line, QMB, MCC, and Busway applications is simple. The QMB fusible switch, 6 in. MCC bucket, I-Line and Busway plug-on units come with the SPD factory-built into these devices.

• Meets requirements of CSA C22.2 No. 8-M1986• Audible alarm with enable/disable switch, dry contacts, and surge

counter standard.• Standard internal 200 k AIC surge rated fusing

• Standard internal 200 k AIC surge rated fusing• Short circuit current rating 200 kA• EMI/RFI filtering

Table 6.10: Internally Mounted—Retrofit

VoltageSurge

Current Rating

I-Line Branch Unitsb QMB Branch Unitsc Busway Units Model 6 MCC Unitse

Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Pricef Cat. No. $ Priceg

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.

120/240 V,1-phase, 3-wire

120 kA FC1IMA12C 5289.00 FI1IMA12C 5683.00 QMB1IMA12C 3867.00 — — — —160 kA FC1IMA16C 5836.00 FI1IMA16C 6275.00 QMB1IMA16C 4354.00 — — — —240 kA FC1IMA24C 7878.00 FI1IMA24C 8707.00 QMB1IMA24C 5941.00 — — — —

208Y/120 V,3-phase, 4-wire

a

120 kA FC2IMA12C 5510.00 FI2IMA12C 5905.00 QMB2IMA12C 4016.00 — — MCC2IMA12C 12000.00160 kA FC2IMA16C 6082.00 FI2IMA16C 6521.00 QMB2IMA16C 4523.00 PIU2IMA16C 8944.00 MCC2IMA16C 16000.00240 kA FC2IMA24C 8648.00 FI2IMA24C 9083.00 QMB2IMA24C 6195.00 PIU2IMA24C 12814.00 MCC2IMA24C 23000.00

240/120 V,3-phase, 4-wireHigh-leg Delta

120 kA FC3IMA12C 5510.00 FI3IMA12C 5905.00 QMB3IMA12C 4016.00 — — MCC3IMA12C 12000.00160 kA FC3IMA16C 6082.00 FI3IMA16C 6521.00 QMB3IMA16C 4523.00 PIU3IMA16C 8944.00 MCC3IMA16C 16000.00240 kA FC3IMA24C 8648.00 FI3IMA24C 9083.00 QMB3IMA24C 6195.00 PIU3IMA24C 12814.00 MCC3IMA24C 23000.00

480Y/277 V,3-phase, 4-wire

ad

120 kA FC4IMA12C 5733.00 FI4IMA12C 6131.00 QMB4IMA12C 4167.00 — — MCC4IMA12C 13000.00160 kA FC4IMA16C 6330.00 FI4IMA16C 6770.00 QMB4IMA16C 4694.00 PIU4IMA16C 9480.00 MCC4IMA16C 17000.00240 kA FC4IMA24C 9024.00 FI4IMA24C 9460.00 QMB4IMA24C 6450.00 PIU4IMA24C 13584.00 MCC4IMA24C 25000.00

600Y/347 V,3-phase, 4-wire

a

120 kA — — FI8IMA12C 6366.00 QMB8IMA12C 4326.00 — — MCC8IMA12C 14000.00160 kA — — FI8IMA16C 7031.00 QMB8IMA16C 4872.00 PIU8IMA16C 9838.00 MCC8IMA16C 9000.00240 kA — — FI8IMA24C 9386.00 QMB8IMA24C 6718.00 PIU8IMA24C 14096.00 MCC8IMA24C 27000.00

a Can be used on 4-wire or 3-wire grounded neutral system.b Requires 13.5" mounting height.c Requires 9" mounting height.d 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

e Requires 6" mounting height.f PE7 Discount Scheduleg PE4 Discount Schedule

Note: If required, order remote monitor from page 6-2.

PanelboardsRefer to Section 9

NF NQ

Switchboards and SwitchgearRefer to Section 11

PZ4 QED

Motor ControlCenters Refer to

Section 17

Integrated Power andControl Centers

Refer to Section 10

MCC IPAC2

I-Line Surgelogic® SPD Unit

QMB Surgelogic SPD Unit

Busway Surgelogic SPD Unit

MCC Surgelogic SPD Unit

PE4 PE7 PE1A Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 5: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

© 2009 Schneider ElectricAll Rights Reserved

6-5

Surge Protective Devices DIN Rail Mounted Multi 9™ Surge Protective DevicesRefer to Catalog 6671CT9701

Surgelogic OEM/Assembler KitSurgelogic® OEM/assembler kits allow manufacturers to add industry-leading surge protection directly to customized equipment. Manufacturers benefit from shorter wire lengths that optimize the clamping voltage of the SPD. Products come with a backplane-mounted SPD, mounting hardware and diagnostic display with 36" cables. Audible alarm, silence switch, remote monitoring contacts, and surge counter are standard.UL 1449 Recognized.

a Can be used on 4-wire or 3-wire grounded neutral system.b Note the last character of the catalog number is the letter “O”, not a zero.c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

DIN Rail Mounted Multi 9™ Surge Protective DevicesMulti 9 SPDs offer a compact solution for protecting electronic equipment from the damaging effects of surges. These parallel, DIN-rail mountable, terminal-connected devices include 1-pole, 2-pole and 4-pole models with up to 80kA of surge protection. This product is ideal for control-panel manufacturers and electrical installers requiring integral power protection. They must be used in conjunction with the Multi 9 family of circuit breakers and supplementary protector products to provide safe, reliable, surge protectionUL, cUL, and IEC (CE Mark) listings to meet international requirements

• Designed for OEMs to protect electronic equipment from damaging surges• DIN rail mounting and compression terminals simplify installation • 1-pole, 2-pole and 4-pole with up to 80 kA surge current rating; 120 to 400 Vac• Status indication LED on all models• Thermally fused for added protection• Optional Form C dry contacts for remote monitoring• Used in conjunction with Multi 9 supplementary protectors—reference Table 6.12 below

OEM Kit

Table 6.11: OEM/Assembler KitsServiceVoltage

Peak Surge Current Ratingper Phase (kA) Cat. No.b $ Price

Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter.

120/240 V,1-phase, 3-wire

+ground

120 TVS1IMA12O 4137.00160 TVS1IMA16O 4547.00240 TVS1IMA24O 6753.00

208Y/120 V,3-phase, 4-wire

+ground a

120 TVS2IMA12O 4331.00160 TVS2IMA16O 4760.00240 TVS2IMA24O 7082.00

120/240 V,3-phase, 4-wire

+ground High-leg Delta

120 TVS3IMA12O 4331.00160 TVS3IMA16O 4760.00240 TVS3IMA24O 7082.00

480Y/277 V,3-phase, 4-wire

+ground ac

120 TVS4IMA12O 4526.00160 TVS4IMA16O 4976.00240 TVS4IMA24O 7413.00

600Y/347 V,3-phase, 4-wire

+ground a

120 TVS8IMA12O 4751.00160 TVS8IMA16O 5199.00240 TVS8IMA24O 7760.00

Table 6.12: DIN Rail Mounted Multi 9™ Surge Protective Devices

Service Voltage Number of Poles

Peak Surge Current

Dry Contacts Cat. No. Rating $ Price

Multi 9™ C60N Supplementary Protectors

1P 2P 3P 4P

120 V, Single Phase 1

20 kA No 12710 10 A, Curve B 94.00 MG24116 — — —

45 kANo 12713 20 A, Curve B 161.00 MG24119 — — —Yes 12714 20 A, Curve B 189.00 MG24119 — — —

65 kANo 12719 25 A, Curve B 243.00 MG24120 — — —Yes 12720 25 A, Curve B 269.00 MG24120 — — —

120/240 V, 1-phase, 3-wire 2

20 kA N/A 12725 10 A, Curve B 136.00 — MG24131 — —45 kA N/A 12727 20 A, Curve B 215.00 — MG24134 — —

208Y/120 V, 3-phase, 4-wire 4

20 kANo 12729 10 A, Curve B 269.00 — — MG24146 MG24161Yes 12730 10 A, Curve B 323.00 — — MG24146 MG24161

45 kANo 12733 20 A, Curve B 484.00 — — MG24149 MG24164Yes 12734 20 A, Curve B 538.00 — — MG24149 MG24164

80 kANo 12737 25 A, Curve C 660.00 — — MG24470 MG24487Yes 12738 25 A, Curve C 713.00 — — MG24470 MG24487

OE1A Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 6: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

6-6 © 2009 Schneider ElectricAll Rights Reserved

Surge Protective DevicesRefer to Catalog 6671CT9701

HWA Series Non-Modular, Nipple-Mounted Surge Protective DeviceThe Surgelogic® HWA series surge protective device is a non-modular, nipple-mounted parallel connected surge protective device. A surge suppression path is provided for each mode, line-to-neutral (L–N), line-to-line (L–L), line-to ground (L–G), and neutral-to-ground (N–G). Each mode is individually fused and uses circuitry with thermal cutouts. On-line diagnostics continuously monitor the device status.Listed to CULUS 1449 Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009), and UL 1283 where applicable. Meets requirements of fourth edition CSA C22.2 No. 8-M1986.• Audible alarm indicates a fault condition• Compact design provides easy mounting inside or outside the equipment cabinets• Dry contacts• Does not contain alarm enable/disable switch

a Can be used on 4-wire or 3-wire grounded neutral system.b 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

XW Series Non-Modular, Nipple-Mounted Surge Protective DeviceThe XW Series SPD is a multi-phase surge suppressor rated at 100 kA per phase. It is compact and affordable and comes in a variety of voltage configurations, including Delta. The XW Series SPD is designed for use in industrial, commercial, and residential applications and comes standard in a NEMA 4 housing.Listed to UL 1449 Second Edition rev. 2/9/2007, cUL Listed, and CSA 22.2 No. 8-M1986.• Audible alarm indicates a fault condition• Compact design provides easy mounting inside or outside the equipment cabinets• Dry contacts• Does not contain alarm enable/disable switch

a MCOV = Maximum Continuous Operating Voltageb 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240

XR Series Nipple-Mounted Surge Protective DeviceThe XR Series SPD provides high-quality surge protection in a compact and versatile package. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, commercial, and residential applications for single-phase power systems.UL, cUL Listed, UL 1449 Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009), CSA 22.2 No. 8-M1986• 40 kA surge rating• Short circuit current rating 25 kA• NEMA 4X housing suitable for indoor or outdoor application• Audible alarm standard• Convenient back or side nipple mounting locations available

Table 6.13: HWA Series Non-Modular, Nipple-Mounted Surge Protective DeviceService Voltage

Peak Surge Current Rating per Phase (kA)

NEMA 3R, 4X, 12 Cat. No. $ Price

120/240 V,1-phase, 3-wire

+ground

50 TVS1HWA50X 1399.0080 TVS1HWA80X 1560.00

120 TVS1HWA12X 1995.00

208Y/120 V,3-phase, 4-wire

+ground a

50 TVS2HWA50X 1492.0080 TVS2HWA80X 1648.00

120 TVS2HWA12X 2118.00

120/240 V,3-phase, 4-wire +ground

High-leg Delta

50 TVS3HWA50X 1492.0080 TVS3HWA80X 1648.00

120 TVS3HWA12X 2118.00

480Y/277 V,3-phase, 4-wire

+ground ab

50 TVS4HWA50X 1549.0080 TVS4HWA80X 1705.00

120 TVS4HWA12X 2198.00

Table 6.14: XW Series Non-Modular, Nipple-Mounted DeviceService Voltage Surge Capacity MCOVa Cat. No. $ Price

120/240 V, 1-phase 100 kA/phase 150/300 V TVS1XW100C 1764.00208Y/120 V, 3-phase 100 kA/phase 300/150 V TVS2XW100C 1875.00240D/120 V, 3-phase 100 kA/phase 300/150 V TVS3XW100C 1875.00

480Y/277 V, 3-phaseb 100 kA/phase 640/320 V TVS4XW100C 2024.00480D V, 3-phase 100 kA/phase 640 V TVS5XW100C 2150.00240D V, 3-phase 100 kA/phase 300 V TVS6XW100C 1875.00

600Y/347 V, 3-phase 100 kA/phase 780/390 V TVS8XW100C 2024.00600D V, 1-phase 100 kA/phase 780 V TVS9XW100C 2150.00

Table 6.15: XR Series Nipple-Mounted Surge Protective DevicesService Voltage Mounting Method Cat. No. $ Price

120/240 V,1-phase, 3-wire +ground

Back Nipple TVS120XR40B 315.00Side Nipple TVS120XR40S 315.00

120 V,1-phase, 2-wire +ground

Back Nipple TVS120XRB 290.00Side Nipple TVS120XRS 324.00

230 V, 1-phase, 2-wire +ground

Back Nipple TVS230XR40B 347.00Side Nipple TVS230XR40S 347.00

Type HWA

Type XW

Type XR

DE2 Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 7: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

© 2009 Schneider ElectricAll Rights Reserved

6-7

Surge Protective Devices Secondary Surge ArrestersClass 6671 / Refer to Catalog 6671CT9701

LC Series In-Line Surge Protective Device and Noise FilterThe LC Series SPD offers high-quality surge protection and noise filtration for any microprocessor-based product, computer, analyzer, PLC, motion control system, original equipment manufacturer (OEM), or any sensitive single phase load. The LC can be connected to the incoming power source (20 A or less) to isolate the control cabinet from the outside environment. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, commercial, or residential applications. The LC uses a series/hybrid suppression circuit that delivers 40,000 peak amps of surge protection with true sine wave tracking protection up to -75 dB of noise filtration.UL 1449 Second Edition rev. 2/9/2007 330 Vac clamping rated. CURUS, CSA, and CE recognized, CSA C22.2 No. 0-M91, CSA C22.2 No. 8-M1986, CSA C22.2 No. 42-M1984, CSA C22.2 No. 21-M90• 40 kA surge rating• Short circuit current rating 10 kA maximum• Optional Form C dry contact status output• DIN rail or direct panel mounting• LED status indication• -75 db noise filtration sine wave tracking

a Optional Form C Dry Contact—Add “C” suffix to catalog number, e.g. TVS120LC5C. Option Price $60.00

Hard-Wired Secondary Surge ArrestersThe SDSA1175 Secondary Surge Arrester is designed and listed for indoor or outdoor installation and surge protection of single-phase three-wire 120/240 Vac 60 Hz electrical services and major appliances. Two SDSA1175 Secondary Surge Arresters can be installed to provide protection on 208Y/120 Vac three-phase four-wire services.The SDSA3650 Secondary Surge Arrester is designed and listed for indoor or outdoor installation and surge protection of three-phase grounded electrical services up to 600 Vac. and is used extensively in service entrance panels to provide an efficient and economical means of surge protection.CULUS secondary surge arresters. Meets ANSI/IEEE C62.11-1993 and meets requirements of NEC Article 285. SDSA3650 Listed to UL Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009).• Suitable for indoor and outdoor applications (NEMA 4X housing)• LED indicates operational status• SDSA1175 36 kA per phase• SDSA3650 40 kA per phase

b See Table 6.18 for QOSAMK mounting kit for installation in QO load centers.c Do not use on ungrounded systems. Systems must be solidly grounded.

Mounting Brackets for Nipple-Mounted DevicesThe nipple products shown in this catalog provide a convenient means of incorporating SPD protection within a new or existing cabinet. The mounting bracket (below) is designed for easy mounting of nipple products inside enclosures.

Table 6.16: LC Series In-Line Surge Protective Device and Noise FilterService Voltage Rated Load Current Cat. No.a $ Price

120 V, 1-phase

5 A TVS120LC5 255.0010 A TVS120LC10 282.0015 A TVS120LC15 308.0020 A TVS120LC20 330.00

230 V, 1-phase

5 A TVS230LC5 255.0010 A TVS230LC10 282.0015 A TVS230LC15 308.0020 A TVS230LC20 330.00

Type LC

Secondary Surge ArrestersThe Secondary Surge Arrester (SDSA) series products are designed primarily to protect against external surges at service entrance panels. They are designed and tested to be used on the line side or the load side of the main service disconnect switch. These devices may also be used for surge protection of irrigation pumps, oil pumps and motors operating below 600V.

Table 6.17: Hard-Wired Secondary Surge ArrestersDescription Cat. No. $ Price

Secondary Surge ArresterFor 1-phase, 3-wire systems.150 Vac phase-to-ground maximum.

SDSA1175b 61.00

Secondary Surge Arrester and Surge Protective DeviceFor 3-phase systems.600 Vac phase-to-ground maximum.c

SDSA3650 165.00

Table 6.18: Mounting Bracket for EnclosuresDescription Cat. No. $ Price

Mounts to QO®, Homeline® Load Center and other enclosures QOSAMK 7.60

SDSA1175

SDSA3650

QOSAMK

DE1B Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 8: Table of Contents Section 6 - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/45175-6.pdf · QO ®, NQ, and Homeline ... (SWT) Sine Wave Tracking 800.00 Table 6.4: HRG Modular

www.schneider-electric.us

6S

UR

GE

PR

OT

EC

TIV

E D

EV

ICE

S

6-8 © 2009 Schneider ElectricAll Rights Reserved

Surge Protective Devices Secondary Surge ArrestersClass 6671 Refer to Catalog 6671CT9701

Surgebreaker® Plus Whole House Surge Protective DeviceThe Surgebreaker® Plus Whole House Surge Protector provides protection against electrical surges to AC power, telephone, and television cables. Installed next to your circuit breaker power panel, the device is hard-wired to the electrical panel and accommodates up to four telephone lines (eight with optional telco unit) and two 75 ohm coaxial television cable or satellite protection. The Surgebreaker® Plus device can be surface or flush mounted, depending on your power panel installation.Listed to UL 1449 Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009). Meets requirements of NEC® Article 285, ANSI/IEEE C62.41.1, C62.41.2, C62.45, and CSA C22.2 No. 8-M1986.• AC line protection single phase three wire—120/240 Vac• Four line telephone protection standard with tool-less insulation displacement connectors (IDC)• Two line coaxial protection for CATV standard• LED status indicator• Space for additional telephone protector• Space for additional coaxial protector (CATV or Satellite)• Modular design with optional accessories• 80 kA per phase AC protection

Surgebreaker® Plus Low-Voltage Only Surge Protective DeviceThe Surgebreaker® Plus Low Voltage Module provides protection against electrical surges to telephone, and television cables. Installed next to your Telephone and Cable entrance point. The device accommodates up to four telephone lines (eight with optional telco unit) and two 75 ohm coaxial television cable or satellite protection.Listed to UL 497 A and B.• Non-metallic NEMA 3R enclosure can be installed indoor or outdoor• Four line telephone protection standard with tool-less insulation displacement connectors (IDC)• Two line coaxial protection for CATV or satellite• Space for additional telephone protector• Space for additional coaxial protector • Modular design with optional accessories

Surgebreaker® Plus AccessoriesAdd additional protection or replace existing modules in any of the three Surgebreaker Plus products.

QO, NQ, and Homeline Panelboard Surge Protective DeviceThe Square D Surgebreaker® surge protective device is an easy to install plug-in unit that installs as quickly as a standard circuit breaker. The Surgebreaker® uses two pole spaces in a QO or Homeline loadcenter, or NQ panelboard.CULUS Listed secondary surge arrester, and Listed to UL 1449 Second Edition rev. 2/9/2007 (Third Edition effective 9/29/2009). Meets ANSI/IEEE C62.11-1993; CSA C22.2 No. 233.1-87, and NEC Article 285.• QO2175SB for QO® load centers and combination devices, NQ panelboards• HOM2175SB for Homeline® load centers and combination devices• Plug-on design requires two pole spaces• LED indicates operational status• 27 kA per phase AC protection

Table 6.19: Whole House Surge Protective DeviceDescription Cat. No. $ Price

Surgebreaker Plus NEMA 1 SDSB1175C 420.00

Surgebreaker Plus NEMA 3R

SDSB1175R

491.00

Table 6.20: Low-Voltage Only Surge Protective DeviceDescription Cat. No. $ Price

Low Voltage Surge Suppressor SDSA4P2VR 173.00

Table 6.21: AccessoriesDescription Cat. No. $ Price

4-Line Telephone Protector with tool-less IDC terminations SDSA4P 67.00Dual Line CATV or Satellite Protector SDSA2V 60.00AC Line Surge Protective Module SDSA1AC 210.00

Table 6.22: QO, NQ, and Homeline Panelboard Surge ArrestersDescription Cat. No. $ Price

QO Surgebreaker for QO and NQCULUS Listed Secondary Surge Arrester150 Vac line-to-ground maximum.

QO2175SB 106.00

Homeline SurgebreakerCULUS Listed Secondary Surge Arrester150 Vac line-to-ground maximum.

HOM2175SB 106.00

SDSB1175C SDSB1175R

New!

SDSA4P2VR

New!

SDSA4P SDSA1ACSDSA2V

New!

QO2175SB HOM2175SB

DE1B Discount Schedule

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com


Recommended