...to complete your network CONTEG SOLUTIONS for the next decade! 1 CONTEG DATA SHEET VENTILATION UNITS & FANS  ACTIVE DOOR TARGETED COOLING version: 16-04-2012 CONTEG, spol. s r.o. Headquarters Czech Republic: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420 261 219 182 Fax: +420 261 219 192 [email protected] www.conteg.com Local Branches/Offices: Austria: +43 699 1819 7071 Benelux: +32 477 957 126 Eastern Europe / Nordics: +49 172 8484 346 France, Maghreb: +33 686 074 386 Germany / Switzerland / Baltics / Denmark / Italy: +49 170 523 4958 Middle East: +971 555 08 32 41 Russia, CIS: +7 495 967 3840 Slovakia: +421 917 874 111
Transcript
Page 1: TARGETED COOLING VENTILATION UNITS & FANS & ACTIVE DOOR

...to complete your network

CONTEG SOLUTIONSfor the next decade!

1

CONTEG DATA SHEET

VENTILATION UNITS & FANS &   ACTIVE DOOR

TARGETED COOLING

version: 16-04-2012

CONTEG, spol. s r.o.

Headquarters Czech Republic:Na Vítězné pláni 1719/4140 00 Prague 4

Tel.: +420 261 219 182 Fax: +420 261 219 192

[email protected]

Local Branches/Offices:Austria: +43 699 1819 7071Benelux: +32 477 957 126Eastern Europe / Nordics: +49 172 8484 346 France, Maghreb: +33 686 074 386Germany / Switzerland / Baltics / Denmark / Italy: +49 170 523 4958 Middle East: +971 555 08 32 41Russia, CIS: +7 495 967 3840Slovakia: +421 917 874 111

Page 2: TARGETED COOLING VENTILATION UNITS & FANS & ACTIVE DOOR

...to complete your networkwww.conteg.com

CONTEG SOLUTIONSfor the next decade!

2

DP-VEN-02

DP-VEN-03DP-VEC-03

DP-VEN-04

DP-VEN-05

DP-VEN-06DP-VEC-06

DP-VEN-07

DP-VEN-08

DP-VEN-09DP-VEC-09

19" mounting ventilation unitConnecting kit for installation in top or

bottom frame of free standing racks depth 1000mm

Connecting kit for installation in top orbottom frame of free standing racks

depth 600, 800 or 1200mm

DP-VER-03

DP-VER-03F

DP-VER-06

DP-VER-06F

DP-VER-031

DP-VER-031F

DP-VER-061

DP-VER-061F

DP-VER-091

DP-VER-091F

Used to force airflow through a rack to assist with cooling.

DESCRIpTION:• Twotoninefans• Possibletoinstall:

a) in 19" extrusions – horizontally b) intoporbottomframeoffree‑standingrack

• Connectingkitforventilationunitisneededwheninstallingintoporbottomframe

• Temperaturerange‑10°Cto55°C• Thermostatintherange0°C – 60°Cincluded;

optionally no thermostat• Voltagerange230V/50Hz(optionally48VDC)• ProtectioncategorytoEN60529IP20• ColorpowdercoatedRAL(standardRAL9005)• High‑endversionwiththemostefficientECfansDP‑VEC‑xx

• AllDP‑VENandDP‑VECunitsarecompatiblewith all Conteg products

VENTILATION UNITS

DP‑VEN‑06

Information on installation options (into top or bottom frame of ROR rack series) on request

EC TECHNOLOGY:Efficient,ecological,economical!New high quality fans feature electro‑nically commuted synchronic mo‑tors, well known as „EC motors“. The main advantage of this technology is a very low power consumption in compa‑risontothestandardACmotors.Forexample–powerconsumptionofournewDP‑VECventilationunitisseventimeslowerthenthestandardDP‑VENwithequalair‑flow.Onthetopofit,DP‑VECprovidesupto60%biggerair‑flowwithequalnum‑beroffansandrequiredairpressureincomparisonwiththestandardDP‑VEN.

Ventilation unit selection:Ifyouneedtoremoveheatfromacabinet,justmakeaneasycalculationtofindacorrecttypeoftheventilationunit.Followingtwoentriesareneededforthecalculation:(1)MaximumairtermperatureintheITroomand(2)amaximumtem‑peratureoftheairexhaustedfromthetechnologyinstalledinsidethecabinet.Thencalculatethetemperaturedifference(incaseitisunknownuse3or5°C)tousethisformula:

N = Q * A /ΔtN=numberoffansQ=exhaustedheatload(W)Δt=calculatedtemperaturediffeence(Kor°C)forDP‑VEN.....A=0,02626forDP‑VEC.....A=0,01634SelectventilationunitwiththesameasthecalculatedNorhighernumberoffans.Thiscalculationisonlyestimate.Contegcannotbearresponsibilityforincorrectselection.Remember! The heat exhausted from the cabinet increases the room temperature so the room ventilation has to besufficientorair‑conditionmustbeused.

Page 3: TARGETED COOLING VENTILATION UNITS & FANS & ACTIVE DOOR

...to complete your networkwww.conteg.com

CONTEG SOLUTIONSfor the next decade!

3

FRAME OF RACK

VENTILATION UNIT

CONNECTING FRAME

ANGLE FITTING

SCREW M5

SCREW M5

SCREW M5X15

DP-VEN-02 (03)DP-VEC-03

DP-VEN-04 (05, 06)DP-VEC-06

DP-VEN-07 (08, 09)DP-VEC-09

DP‑VE‑ROV2

DP‑VE‑ROV4

DP‑VE‑ROF4/100Side panel installation Special perforation VH or -TH

Used to force airflow through a rack where ventilation unit is not used.

DESCRIpTION:• Possibletoinstall: a)onsideortopofwall‑mountingrack–specialperforationneeded

(orderingcodeofthewallmountingracktobeextended:‑VHfor2xsideperforationor–THfor2xtopcoverperforation;bothforDP‑VE‑01only‑VCfor2xcentreorientedholesforDP‑VEN‑01)

b)intoporbottomframeofdistributionrack ‑requiresperforatedglandplateDP‑VE‑ROV2orDP‑VE‑ROV4

• Mountingkitincluded• Twoversions(ACtechnology):‑withthermostatatsteelbox‑DP‑VEN‑01‑withoutthermostat‑DP‑VE‑01(for‑VHor‑THopenings)

FANS

DP‑VEN‑01

Code Air flow (m3/h)

Rated current max. (A)

Power consumption (W)

Annual power consumption1)

(kWh/year)

Possible heat

removal 2)

(kW)

Standard AC fans

SpecificFanPower(SFP)=611W/(m3/s)

DP‑VEN‑02 224 0,180 38 333 0,38

DP‑VEN‑03 336 0,270 57 499 0,57

DP‑VEN‑04 448 0,360 76 666 0,76

DP‑VEN‑05 560 0,450 95 832 0,95

DP‑VEN‑06 672 0,540 114 999 1,14

DP‑VEN‑07 784 0,630 133 1165 1,33

DP‑VEN‑08 896 0,720 152 1332 1,52

DP‑VEN‑09 1008 0,810 171 1498 1,71

NEW PRODUCTS 2012

High-end EC fans

SpecificFanPower(SFP)=88W/(m3/s)

DP‑VEC‑03 540 0,057 13,2 116 0,92

DP‑VEC‑06 1080 0,114 26,4 231 1,84

DP‑VEC‑09 1620 0,171 39,6 347 2,751) in case of non-stop operation2) if temperature difference between intake and exhaust air from the rack is Δt=5K

Page 4: TARGETED COOLING VENTILATION UNITS & FANS & ACTIVE DOOR

...to complete your networkwww.conteg.com

CONTEG SOLUTIONSfor the next decade!

4

ACTIVE DOORThe active door is designed formounting of up to 3 ventilation units,

eachwith6fans(forracksof600mmwidth)and9fans(forracksof800mmwidth).Frontmountedactivedoorensureseffectiveairdelivery intotherack.Therearmountedactivedoorremovesheatedairfromtherack.Activedoors can be where higher density heat loads are required by augmenting thedeliveryorextractionofairforcoolingpurposes.

• Perforatedsheetmetalorventeddoor• Preparationformountingof3ventilationunits,eachwith6fans• Multipoint swivel handle lock• Universal keys• Colour design – powdered paint RAL 7035 or RAL 9005

Apply the appropriate codes in positions describing door type/door lock type in the rack ordering matrix:

• JWforsheetsteelperforateddoor,readyforupto3x6(3x9)‑positionventilation unit, multipoint swivel handle lock, universal key

• KWforventeddoor,readyforupto3x6(3x9)‑positionventilationunit,multipoint swivel handle lock, universal key


Recommended