Date post: | 22-Dec-2018 |
Category: |
Documents |
Upload: | truongnhan |
View: | 221 times |
Download: | 0 times |
241
TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion
TCPO 07 - 09 -11horizontal expulsion
TCPV 16 - 20 - 24 - 35vertical expulsion
Model
TCPO 07 with horizontal expulsionTCPO 09 with horizontal expulsionTCPO 11 with horizontal expulsionTCPV 16 with vertical expulsionTCPV 20 with vertical expulsionTCPV 24 with vertical expulsionTCPV 35 with vertical expulsion
Code
39000000390000013900000239000003390000043900000539000006
PowerThermal kW
6,958,98
10,9916,5119,8124,2135,26
Pool volume*m3
< 40< 50< 60< 95< 115< 140< 200
€
3.770,004.380,004.780,007.780,008.500,009.680,00
14.180,00* Volumes expressed as an indication. For the actual estimate, it is appropriate to consider the specific characteristics of each pool (according to the thermal study).
242
TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion
4 good reasons to choose heaters for heat pumps for swimming pools
1) Titanium heat exchanger: safety guaranteeand reliability All heat pump heaters A2B Accorroni E.G. are equipped with a titanium exchanger able to heat any type of water, regardless of the origin and treatment used (chlorine treatment, salt, bromine, ozone sterilization, etc.) and all plants with extensive disinfection requirements . The titanium alloy ensures maximum protection, guaranteed over time, against corrosion caused by chlorine.
2) EvaporatorThe evaporator of the TPCV units from 16 to 35 kW is made of hydrophilic aluminum fins and internally grooved copper tube to increase its heat exchange capacity, efficiency and corrosion resistance.All heat pump heaters A2B Accorroni E.G. work with R410A refrigerant fluid.
3) Resistant materials: ABS pump bodyAll units are covered by an external shell in thermoformed ABS that is not subject to corrosion. This coating makes it possible to install all the products in the open air, without the risk of deterioration caused by atmospheric agents or the need for special maintenance.
4) Heat in silenceHeat pump heaters A2B Accorroni E.G. boast the best noise levels on the market today: up to a minimum of 32 dB(A)
All heat pump heaters A2B Accorroni E.G. they can be installed in an easy and immediate way: by simply connecting the swimming pool and the system, the hot water produced will be directly inserted between the inlet and outlet pipes of the unit.
Diagram of heat pump system for swimming pools TCPO 07 ÷ 11 - TCPV 16 ÷ 35
Light Light
Water jet
Main exhaust
Filter
exhaust
Heat pump
Pump
Entrance
243
Dimensions TCPV 16 ÷ 35 vertical expulsion
TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion
Dimensions TCPO 07÷11 horizontal expulsion
L
P
A
666,
51.074,7
400
TCPVLPA
16702700
842,5
19751750
892,5
24751750
892,5
35901920
1056Values expressed in mm
244
DESCRIPTIONPerformance at the following conditions: outside air temperature 15 °C / water temperature inlet 13 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 15 °C / inlet water temperature 26 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 20 °C / inlet water temperature 24 °CThermal powerAbsorbed powerCurrent consumptionCOPCompressorR410A Refrigerant GasWater flow
Adjustable water temperature range Heating
Cooling downAir temperature rangePower supplySound levelDegree of protectionNet weight
TCPO 07÷11 - TCPV 16÷35Pools Heat pump horizontal and vertical expulsion
DESCRIPTIONPerformance at the following conditions: outside air temperature 15 °C / water temperature inlet 13 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 15 °C / inlet water temperature 26 °CThermal powerAbsorbed powerCurrent consumptionCOPPerformance at the following conditions: outside air temperature 20 °C / inlet water temperature 24 °CThermal powerAbsorbed powerCurrent consumptionCOPCompressorR410A Refrigerant GasWater flow
Adjustable water temperature range Heating
Cooling downAir temperature rangePower supplySound levelDegree of protectionNet weight
TPCO 07
6,951,115,126,26
6,291,285,854,91
6,981,205,485,82
0,953,10
15÷408÷28
-10÷43
32
49
TPCO 09
8,981,446,606,24
8,281,697,694,90
9,041,556,965,83
Rotary1,303,95
15÷408÷28
-10÷43230V/1/50Hz
33IPX454
TPCO 11
10,991,809,106,11
10,182,089,924,89
11,201,949,335,77
1,504,80
15÷408÷28
-10÷43
34
61
U.M.
kWkWA
kWkWA
kWkWA
kWkg
m3/h°C°C°C
dB(A)
kg
Technical data table TCPO 07÷11 horizontal expulsion
TPCV 16
16,512,68
13,686,16
15,022,95
15,065,10
16,983,00515,155,65
2,504,2÷8,615÷408÷28
-10÷43230V/1/50Hz
32
103
TPCV 20
19,813,235,516,13
18,013,555,995,07
20,353,626,105,62Scoll2,70
5,1÷10,415÷408÷28
-10÷43
33
110IPX4
TPCV 24
24,213,936,326,16
22,014,316,945,11
24,904,406,935,66
3,406,3÷12,615÷408÷28
-10÷43400V/3+N/50Hz
34
116
TPCV 35
35,265,789,306,10
32,056,41
10,325,00
36,306,47
10,195,61
4,609,2÷18,015÷408÷28
-10÷43
35
166
U.M.
kWkWA
kWkWA
kWkWA
kWkg
m3/h°C°C°C
dB(A)
kg
Technical data table TCPV 16 ÷ 35 vertical expulsion