2
UPPER ARM BLOOD PRESSURE MONITOR TD-3140 Large Memory 200 www.taidoc.com HI Smartphone App for cardiovascular evaluation Fast Heart Beats Heart rate: > 110 bpm. Slow Heart Beats Heart rate: < 50 bpm. Irregular Heart Beats Heart rate: premature, delayed contraction, skipped, pause between heartbeats, extra systole. Atrial Fibrillation Heart rate: > 100 bpm, quivering or irregular heartbeat. Cardiovascular Evaluation Evaluation: cardiovascular or age assessment. LO IHB AF Backlight Irregular Heartbeat Detection Average 3 measurements
Transcript
Page 1: TD-3140B DM v2 - taidoc.com · Title: TD-3140B_DM_v2 Author: JF Keywords: Area: TaiDoc Logo: No logo Purpose: DM Model: TD-3140 Size: W210 x H297cm Printing Specifications: NA

UPPER ARM BLOOD PRESSURE MONITORTD-3140

LargeMemory

200

www.taidoc.com

HI

Smartphone App for cardiovascular evaluationFast Heart BeatsHeart rate: > 110 bpm.

Slow Heart BeatsHeart rate: < 50 bpm.

Irregular Heart BeatsHeart rate: premature, delayed contraction, skipped, pause between heartbeats, extra systole.

Atrial FibrillationHeart rate: > 100 bpm, quivering or irregular heartbeat.

Cardiovascular EvaluationEvaluation: cardiovascular or age assessment.

LO

IHB

AF

BacklightIrregular HeartbeatDetection

Average 3measurements

Page 2: TD-3140B DM v2 - taidoc.com · Title: TD-3140B_DM_v2 Author: JF Keywords: Area: TaiDoc Logo: No logo Purpose: DM Model: TD-3140 Size: W210 x H297cm Printing Specifications: NA

SPECIFICATIONSAccuracy of Pressure

Accuracy of Heart Rate

Measurement Range

Memory Capacity

Communication

Power Source

Dimension

Weight

Operating Condition

Battery Life

Power Saving

Backlight

Units per Carton

Net Weight per Carton

Gross Weight per Carton

Carton Size

Cuff Size

±3 mmHg or ±2% of reading

±4% of reading

Systolic: 60 ~ 255 mmHg / Diastolic: 30 ~ 195 mmHg

Pulse rate: 40~199 / minute

200 sets

Bluetooth smart

4 x AAA

145 (L) x 64.5 (W) x 29.6 (H) mm

240 g (without battery)

5 ºC ~ 40 ºC; Humidity 15% ~ 93%

At least 200 measurements

180 seconds

LCD backlight

30

12.63 kg

13.63 kg

L42 x W39 x H41 cm

Wide Range: 24 ~ 43 cm, M Size: 24 ~ 35 cm

www.taidoc.com

B1-7F., No. 127, Wugong 2nd Rd., Wugu Dist., New Taipei City 24888, TaiwanTel : +886-2-6625-8188 Fax : +886-2-6625-0288

TaiDoc Technology Corp.

MbH BP


Recommended