TDK Corporation Passive Application Center Jan. 19, 2016 TDK Component Library for ANSYS ® Designer ® ver. 2016.01
Transcript

TDK CorporationPassive Application Center

Jan. 19, 2016

TDK Component Library forANSYS® Designer®

ver. 2016.01

Copyright© 2016 TDK Corporation. All rights reserved. - 1 -2016.01 K.EPAC

Caution< Applicable condition >The data in this library is obtained under the condition of 25ºC, no DC bias, and small signaloperation. Proper result might not be obtained if your condition is different from the above one.

< Terms and conditions regarding TDK Simulation Models >(1) This simulation model is being provided solely for informational purposes. Please refer to the

specifications of the products in terms of detailed characteristics of such products.(2) In no event shall TDK Corporation of any of its subsidiaries be liable for any loss or damage

arising, directly or indirectly, from any information contained in this simulation model,including, but not limited to loss or damages arising from any inaccuracies, omissions or errorsin connection with such information.

(3) Any and all copyrights on this simulation model are owned by TDK Corporation. Duplicationor redistribution of this simulation model without prior written permission from TDKCorporation is prohibited.

(4) This simulation model is subject to any modification or change without any prior notice.(5) Neither TDK Corporation nor any of its subsidiaries shall make any warranty, express or

implied, including but not limited to the correctness, implied warranties of merchantability andfitness for a particular purpose with respect to this simulation models.

(6) The use of this simulation model shall be deemed to have consented to the terms and conditionshereof.

* ANSYS, and ANSYS Designer are registered trademarks of ANSYS, Inc.

Copyright© 2016 TDK Corporation. All rights reserved. - 2 -2016.01 K.EPAC

About this library< Feature of this library >

The actual property of components can be taken into your circuit simulation because equivalentcircuit model that considers inner structure of a part and material property is used.Artwork data (recommended pcb pattern) of parts are includedEasy operation like standard ANSYS Designer’s components.

< Supported versions >This library can be used with ANSYS Designer, and Ansoft Designer Student Version. However,this library might not be used depending on a simulation environment. Please acknowledge itbeforehand.

< Contents in this document >This document is described assuming the following environment.

OS: Windows XPAnsoft Designer: version 4.1

On different OS, or versions of ANSYS Designer, screen display and/or operation procedure maynot correspond to the contents of this document. Please acknowledge it beforehand.

Copyright© 2016 TDK Corporation. All rights reserved. - 3 -2016.01 K.EPAC

Update Information< Summary of updates in version 2016.01 >

Product list has been updated.

< Products contained in version 2016.01 >Multilayer Ceramic Chip Capacitors3-Terminal Feedthrough MLCCsInductorsChip Beads3-Terminal FiltersCommon Mode FiltersVaristorsPulse Transformers

Copyright© 2016 TDK Corporation. All rights reserved. - 4 -2016.01 K.EPAC

・・・

How to install the library(R16 and newer)< Library install folder >Install folder of this library is “userlib” folder in the install folder of ANSYS Designer.(e.g. C:¥Program Files¥AnsysEM¥AnsysEM16.0¥Win64¥ElectronicsDesktop¥userlib.)

< Uninstall the previous version >If previous versions of the library is installed, uninstall it from the library install folder.

< Install the library >1) Expand the zip file.2) Move the expanded “TDK” folder into the library install folder. (Execution of ConfigureLibraries, that was needed for R15 or older, is no longer needed for R16.)

1) Expand the zip file.2) Move into “userlib” folder.

Copyright© 2016 TDK Corporation. All rights reserved. - 5 -2016.01 K.EPAC

How to install the library(R15 and earlier) (1)< Library install folder >Install folder of this library is “userlib” folder in the install folder of ANSYS Designer.(normally, it is “C:¥Program Files¥Ansoft¥Designer4¥userlib”.)

< Uninstall the previous version >If previous versions of the library is installed, uninstall it from the library install folder.

< Install the library >1) Expand the zip file.2) Move the expanded “TDK” folder into the library install folder.

1) Expand the zip file.2) Move into “userlib” folder.

Copyright© 2016 TDK Corporation. All rights reserved. - 6 -2016.01 K.EPAC

How to install the library(R15 and earlier) (2)< Register the library >1) Start ANSYS Designer and open a project.2) Select Insert Nexxim Circuit Design on the Project menu and open a schematic window.3) Select Configure Libraries... on the Tools menu then the Configure Design Libraries windowopens.4) Toggle the User Libraries button.5) Select Components in the listbox.6) Select TDK in the Available Libraries and click “>>” button to register the library.7) Repeat step 5 and 6 for Symbol and Footprints as well.8) Put a check mark on Save as default.9) Click the OK button.

2) Select Insert Nexxim Circuit Design.

3) Select Configure Libraries...

1) Open a project.

4) Toggle User Libraries.

5) Select Components7) Repeat Symbol and FootPrints

7) Register “TDK”

8) Check Save as default.

9) Click OK.

Copyright© 2016 TDK Corporation. All rights reserved. - 7 -2016.01 K.EPAC

How to use the library< Putting a component and selecting a part >1) After installing the library, TDK folder will be added in the Components tab of the ProjectManager.2) Drag and drop a component and put a symbol onto the schematic window.3) Double-click the symbol of the component and open the properties window.4) Click Choose Model button in the properties window and open the Model List window.5) Select a product in the Model List window.

1) TDK folder

2) Put a component.

3) Open the setting window.

4) Click Choose Model button.

5)Select a product.6) Click OK.

Copyright© 2016 TDK Corporation. All rights reserved. - 8 -2016.01 K.EPAC

Comparison of model and measurement< Comparison between equivalent circuit models and measured data >Comparison between the equivalent circuit models and measured data are shown in the following.Since the equivalent circuit models well match to measured results as shown in the following pages,simulation result that matches to actual property can be obtained.

Copyright© 2016 TDK Corporation. All rights reserved. - 9 -2016.01 K.EPAC

Comparison of model and measurement (1)

Capacitor "C0603CH1H101J030BA" Capacitor “C1005X5R1A105K050BB”

Copyright© 2016 TDK Corporation. All rights reserved. - 10 -2016.01 K.EPAC

Comparison of model and measurement (2)

3-Terminal Feedthrough MLCC “CKD710JB0G105S030EA”

Copyright© 2016 TDK Corporation. All rights reserved. - 11 -2016.01 K.EPAC

Comparison of model and measurement (3)

Inductor "MLG1005S27NJT000"

Q

0

5

10

15

20

25

30

1M 10M 100M 1G 10G

Frequency [Hz]

Q

Q_modeledQ_measured

L

0

10

20

30

40

50

60

70

80

90

100

1M 10M 100M 1G 10G

Frequency [Hz]

Indu

cta

nce [

nH

]

L_modeledL_measured

Copyright© 2016 TDK Corporation. All rights reserved. - 12 -2016.01 K.EPAC

Comparison of model and measurement (4)

Chip Bead "MMZ0603D800CT000"

Copyright© 2016 TDK Corporation. All rights reserved. - 13 -2016.01 K.EPAC

Comparison of model and measurement (5)

3-Terminal Filter “ACH32C-101”

Copyright© 2016 TDK Corporation. All rights reserved. - 14 -2016.01 K.EPAC

Comparison of model and measurement (6)

Common-Mode Filter “TCM0605G-900-2P"

Copyright© 2016 TDK Corporation. All rights reserved. - 15 -2016.01 K.EPAC

Comparison of model and measurement (7)

Pulse Transformer “ALT3232M-151-T001”

Copyright© 2016 TDK Corporation. All rights reserved. - 16 -2016.01 K.EPAC

Comparison of model and measurement (8)

Varistor “AVR-M2012C390KT6AB”

|Z|, R

0.1

1

10

100

1000

10000

100k 1M 10M 100M 1G 10G

Frequency [Hz]

Impe

dance [

ohm

]

R_modeledR_measured

|Z|_modeled|Z|_measured