+ All Categories
Home > Documents > Team E Presents: Micro Fluidic Paper-Based Assay Device

Team E Presents: Micro Fluidic Paper-Based Assay Device

Date post: 03-Jan-2016
Category:
Upload: zahir-robles
View: 26 times
Download: 1 times
Share this document with a friend
Description:
Alan Dorsinville, Reading High School Natalie Gibbs, Reading High School. Team E Presents: Micro Fluidic Paper-Based Assay Device. Outline. Introduction The Problem and our solution Background Information The purpose of μ PAD’s Materials Procedure Science Concepts Results - PowerPoint PPT Presentation
27
Alan Dorsinville, Reading High School Natalie Gibbs, Reading High School
Transcript
Page 1: Team E Presents: Micro Fluidic Paper-Based Assay Device

Alan Dorsinville, Reading High SchoolNatalie Gibbs, Reading High School

Page 2: Team E Presents: Micro Fluidic Paper-Based Assay Device

Introduction The Problem and our solution Background Information The purpose of μPAD’s

Materials Procedure Science Concepts Results Team F(Floral Experiment) Conclusion/Discussion Further Research Acknowledgements

Page 3: Team E Presents: Micro Fluidic Paper-Based Assay Device

The cost of health care is an issue in America

Testing requires Time Money Insurance Technical Experience Etc

All of which is inconvenientDeveloping Countries

Page 4: Team E Presents: Micro Fluidic Paper-Based Assay Device

Micro fluidic paper-based assay devices (μPAD) A paper diagnostic test

Paper-based devices are Inexpensive Quick Easy to use Require a small volume of liquid Lack the use of advanced equipment Effective and accurate

Page 5: Team E Presents: Micro Fluidic Paper-Based Assay Device

Your body has many substances including proteins and glucose

Glucose provides energy for your body an all of your movements

Glucose Concentration

Disease

0-0.8mM Normal

Above 0.8mM Impaired kidney and/or diabetes

Page 6: Team E Presents: Micro Fluidic Paper-Based Assay Device

Proteins are important for growth, tissue repair, and many other bodily functions

Page 7: Team E Presents: Micro Fluidic Paper-Based Assay Device

Our purpose is to show we can quantify diagnostic results using a cheap paper device Our chips are designed to detect glucose

and protein in our substances

Page 8: Team E Presents: Micro Fluidic Paper-Based Assay Device

Intermolecular forces

Capillary action Allows us to direct small amounts of

liquid to testing wells

Page 9: Team E Presents: Micro Fluidic Paper-Based Assay Device

CleWinChromatography paper( Whatman)PrinterScales, beakers, pipettesVarious chemicals Infrared GunHot PlateScannerAdobe Photoshop

Page 10: Team E Presents: Micro Fluidic Paper-Based Assay Device

Part One: PlanningCleWin is a computer program made

to design our chips

Page 11: Team E Presents: Micro Fluidic Paper-Based Assay Device

Step 1: Printing The pattern is outlined with wax when

printedStep 2: Place the chips on a hot plate

at 150°C Allows wax to seep through

Page 12: Team E Presents: Micro Fluidic Paper-Based Assay Device

This project requires making both a protein and glucose reagent A chemical reagent is a substance used

in a chemical reaction to detect, measure, examine, or produce other substances

Page 13: Team E Presents: Micro Fluidic Paper-Based Assay Device

Buffer (pH=6.0) 0.2 M NaH2PO4 0.2 M Na2HPO4

0.3 M Trehalose0.6 M KI30 units/mL HRP120 units/mL GO

Page 14: Team E Presents: Micro Fluidic Paper-Based Assay Device

Glucose + Glucose oxidase Gluconic acid + Hydrogen

peroxide (H2O2)

H2O2 H2O + ½ O2

I- ½ I2

HR Peroxidase

Brown color

Page 15: Team E Presents: Micro Fluidic Paper-Based Assay Device

Part 1: 0.25 M Citric acid (pH 1.8 buffer) 184 μL H2O, 16 μL EtOH

Part 2: 9 mM TBPB 10 μL H2O, 190 μL EtOH

Protein Mechanism TBPB + protein = Blue color

Page 16: Team E Presents: Micro Fluidic Paper-Based Assay Device

Apply 0.2 μL of reagents using a micropipette. Must wait ten minutes

Part Five: Test One

Page 17: Team E Presents: Micro Fluidic Paper-Based Assay Device

We made a new design for our second chip on CleWin, printed them, and reapplied the chemical reagents, etc.

Page 18: Team E Presents: Micro Fluidic Paper-Based Assay Device

The chips are a urine analysis test so we made an artificial urine sample

We made several concentrations glucose and proteins to test

Sol'n 1 2 3 4 5 6 7 8 9 10 11Glucose 25 18.75 12.5 9.375 6.25 5 3.75 2.5 1.25 0.63 0BSA 25 20.83 16.67 12.5 8.33 4.17 3.125 2.08 0.833 0.42 0Urine 0 10.42 20.83 28.13 35.42 40.83 43.13 45.42 47.92 48.96 50

Page 19: Team E Presents: Micro Fluidic Paper-Based Assay Device

We performed eight tests for each of the eleven different concentrations of glucose and protein

After 30 minutes, the chips were scanned into the computer

Page 20: Team E Presents: Micro Fluidic Paper-Based Assay Device
Page 21: Team E Presents: Micro Fluidic Paper-Based Assay Device
Page 22: Team E Presents: Micro Fluidic Paper-Based Assay Device
Page 23: Team E Presents: Micro Fluidic Paper-Based Assay Device

Team F’s research is focused on the relationship between pollinators and nectar

Page 24: Team E Presents: Micro Fluidic Paper-Based Assay Device

We made adjustments to our second chip to create a more effective test

We were not able to quantify, but still proved the chips had the potential to quantify different detectable substances

We were able to rank the glucose concentration of Team F’s nectar solutions

Page 25: Team E Presents: Micro Fluidic Paper-Based Assay Device

The μPAD’s serve the same purpose as other urine tests Scientists are trying to find ways of

detecting more diseases with the paper-based analytical device

Page 26: Team E Presents: Micro Fluidic Paper-Based Assay Device

We would like to thank:Dr. Scott PhillipsSeeCos FacultyChris DalyMs. Jody MarkleyMr. Derek JamesMs. Jean Marie DonnellyUBMS Staff